Abstract
Achieving non-invasive spatiotemporal control over cellular functions, tissue organization, and behavior is a desirable aim for advanced therapies. Magnetic fields, due to their negligible interaction with biological matter, are promising for in vitro and in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic (including superparamagnetic and ferromagnetic, all with a positive magnetic susceptibility) entities through magnetic instruments has emerged as a promising approach across various biological contexts. However, variations in the properties and descriptions of these instruments have led to a lack of reproducibility and comparability among studies. This article addresses the need for standardizing the characterization of magnetic instruments, with a specific focus on their ability to control the movement of paramagnetic objects within organisms. While it is well known that the force exerted on magnetic particles depends on the spatial variation (gradient) of the magnetic field, the magnitude of the field is often overlooked in the literature. Therefore, we comprehensively analyze and discuss both actors and propose a novel descriptor, termed ‘effective gradient’, which combines both dependencies. To illustrate the importance of both factors, we characterize different magnet systems and relate them to experiments involving superparamagnetic nanoparticles. This standardization effort aims to enhance the reproducibility and comparability of studies utilizing magnetic instruments for biological applications.
Similar content being viewed by others
Introduction
For research, diagnosis, and the application of novel therapies, it is often necessary to spatiotemporally control cellular functions, the organization of tissues, or the location of substances remotely. Within living organisms, achieving these goals with minimal interaction with the biological system presents a significant challenge. Unfortunately, common techniques utilizing light or ultrasound face limitations due to the energy transfer to the cells, and depth of tissue penetration. Conversely, techniques based on magnetic fields present an attractive alternative that has gained popularity. As most biological substances such as organic materials and tissues are diamagnetic or only slightly paramagnetic, they interact very weakly with magnetic fields. Consequently, biological substances can be penetrated non-invasively, and the depth of penetration is just limited by the decay of the magnetic field over distance. On the other hand, objects made from strongly magnetic (i.e. superpara-, ferro- or ferrimagnetic) materials, develop significant magnetization in the presence of magnetic fields. This enables their manipulation by magnetic forces, facilitating remote movement or actuation within larger diamagnetic environments.
This fundamental principle is currently harnessed for various biological applications. One notable application is the magnetic guidance of objects through living organisms for diagnostic or therapeutic purposes. This concept can be applied to objects spanning a wide range of sizes, from millimeters (e.g. endoscopes and capsules1,2), micrometers (e.g. microrobots3,4,5,6) to nanometers (nanoparticles). The latter are employed in drug delivery (magnetic drug delivery or targeting7,8,9), tissue manipulation (by actuation10, hyperthermia11,12, or other localized therapies13,14) at target sites. Furthermore, magnetic guidance can be utilized to move cells15,16, or cellular extensions such as neurites17,18, for applications in tissue engineering and regenerative medicine19,20,21,22. In this context, the strategy involves incorporating nanoparticles into the cells and subsequently applying force through the particles within the cells. Typically, superparamagnetic nanoparticles are used, often coated to improve their biocompatibility, and may have other functional groups or payloads23. Moreover, protein-functionalized superparamagnetic nanoparticles demonstrate the capacity to modulate intracellular signaling24,25, or activate cell receptors and ion channels26. Magnetic guiding can also be used in microfluidics and nanomechanics27. For recent reviews over this very active and interdisciplinary field, we refer to references28,29,30.
In all of these applications, the generation of a suitable magnetic field either by resistive or superconducting electro-, or permanent magnets, is a prerequisite for precise steering, guiding, or actuation. Various guiding concepts31,32,33 and instruments34,35 have been proposed, leading to a plethora of designs. Comparing such instruments is challenging due to the fact that two distinct factors contribute to the efficiency of magnetic guidance. The first is the spatial change of the magnetic field, the so-called gradient, which predominantly determines the force exerted on a particle carrying an oriented magnetic dipole. The second is the absolute (local) strength of the magnetic field, required to induce a dipole in the particle or, in the case of particles with a permanent dipole, to orient them. Both factors must be jointly considered to predict the resulting magnetic force. Unfortunately, the second factor tends to be overlooked in the literature, which results in confusing and misleading discussions of magnetic designs. The publication aims to quantitatively elucidate the interplay between strength and gradient of magnetic fields in generating the magnetic force on particles. The full mathematical formalism involves a tensorial description of magnetic gradients, which complicates the direct comparison of designs. As a practical tool to compare the efficiency of different magnet types for magnetic guiding, we propose a modified physical quantity. This quantity can be conceptualized as an effective magnetic field gradient, presented as a simple three-dimensional vector instead of a tensor. We discuss the suitability of this effective gradient for two commonly used magnet geometries in magnetic guiding.
Theory
Average magnetization of superparamagnetic nanoparticles
At room temperature, soft ferro- or ferrimagnetic material consists of small volume regions known as Weiss domains, wherein the magnetic dipole moments of strength \(\vec {m}_i\), are mutually aligned in the same direction. The density of the sum of all magnetic moments yields the magnetization (see Table 1)
These domains are microscopic in size and separated by (Bloch-) walls. Larger objects consist of numerous such domains (see Fig. 1) with different magnetization directions. The total magnetization \(\langle \vec {M} \rangle\) of the object is the vector sum of the magnetizations of all domains weighted by their volume. Figure 1 shows how an external magnetic field induces shifts of the domain walls, thereby enlarging domains with magnetization components in the same direction as the magnetic field.
This process leads to an increase in total magnetization from zero (\(\langle \vec {M}(\vec {B}=0) \rangle\)) in the absence of a magnetic field—where all subdomain magnetizations cancel each other—to maximum (saturation) magnetization (\(\langle |\vec {M}| \rangle = M_\text {s}\)) at high magnetic fields. Each individual domain is fully magnetized (\(m_i = M_\text {s}V_i\) where \(V_i\) is the size of the domain), but their directional average \(\langle \vec {M}(\vec {B}) \rangle\) depends on the magnetic field.
When the size of the object is of the order of such a domain (typically \(r < 30\) nm), the object eventually consists of only one single, fully magnetized domain. However, due to their small size, their rotational Brownian motion will have a similar effect on the thermally averaged magnetization, \(\langle \vec {M}(\vec {B}) \rangle\), as illustrated on the right side of Fig. 1. The resulting value can be approximated by a Langevin-function, \(\mathfrak {L}(x)\)36,37: the average magnetization \(\langle \vec {M} \rangle\) points in the direction of \(\vec {B}\), and its magnitude is given by
While each particle is fully magnetized, its time-averaged magnetization follows Eq. (2). This behavior is known as superparamagnetism38. Chemical stabilization is required to avoid agglomeration due to mutual dipolar attraction of the particles39. Superparamagnetic particles form the basis of ferrofluids40 and find numerous applications in theranostics41. Independent of their size and ignoring hysteresis effects in the case of multi-domain particles, the macroscopic magnetization \(\langle \vec {M}(\vec {B}) \rangle\) depends on the field according to Eq. (2) and is also strongly dependent on \(M_\text {s}\) and the size/volume V of the magnetic particle (MP).
This is illustrated by Fig. 2 which demonstrates that the field dependence of \(\langle \vec {M}(\vec {B}) \rangle\) or the Langevin-function is linear for very small fields and its steepness strongly depends on the particle size (or the size of the magnetic domains in case of multi-domain particles). The constant saturated region where \(M \approx M_\text {s}\) is reached at lower magnetic fields for larger particles. At higher magnetic fields, the behavior of small particles varies more strongly as a function of field strength than that of larger , uni-domain particles. This also implies that in the same magnetic instruments, smaller particles exhibit a stronger field dependence. We emphasize that Eq. (2) relates the magnitudes of \(\vec {M}, \vec {m}, \text {and } \vec {B}\) to each other, despite their status as spatial vectors. As noted above, \(\langle \vec {M} \rangle\) is parallel to \(\vec {B}\). Given that MPs carry a permanent magnetization, the magnetic field causes the magnetic moments to align with \(\vec {B}\) either via rotation of the whole particle or change of its internal magnetization direction. As a consequence, it can be assumed that (with \(\cdot\) being the dot or scalar product of two vectors)
where \(\xi\) is defined as in Eq. (2).
The magnetic field and its gradient
Another ingredient for calculating the force is the spatial variation of the external magnetic field. It is quite intuitive that magnetized MPs experience no pulling force in a perfectly homogeneous magnetic field, much like a ball on a perfectly flat plate, as moving the particle to different position changes nothing. Pulling forces only arise when there is a change in potential energy with respect to space. In the example of the ball, the potential energy is proportional to its height, and a force can be induced by tilting the plane, such that the height depends on the lateral position. Analogously, the theory of electromagnetism tells us that we can assign a ‘magnetic potential energy’ to a particle with magnetic moment \(\vec {m}\) in a magnetic field \(\vec {B}\), given by \(E_{\text {mag}} = -\vec {B}\vec {m}\)43. This allows us to induce a magnetic force on the MPs by spatial variations in the magnetic field, \(\vec {B}\). However, the situation is complicated by the fact that the magnetic field has three components that can all change with space. The spatial variation must be described in terms of a second rank tensor (with \(\otimes\) being the tensor product)
where \(\partial {B_i}/\partial {x}\) etc. are partial derivatives. Fortunately, as we will soon see, the full knowledge of the tensor is not necessary when calculating the magnetic force on MPs. Nevertheless, Eq. (4) demonstrates that a magnetic system cannot be described by a single value for a magnetic field gradient. Indeed, it is not even possible to generate a single gradient outside magnets (such as, e.g., (\(\partial {B_x}/\partial {x} \ne 0\) , with all other partial derivatives in \(\textbf{grad}\,\vec {B}\) being zero). This is forbidden by the Maxwell equations for electromagnetism, i.e. (with \(\times\) as the cross product of two vectors)
The second equation follows from the fact that a static system (at low frequencies) in the absence of electrical currents is considered. Thus, each gradient must be accompanied by at least another gradient of equal strength and opposite direction or sign. A single magnetic field gradient cannot exist!
Magnetic force
As discussed in the previous section, the force on a MP is given by the gradient of the magnetic potential energy. In the context of an MP with magnetic moment \(\vec {m}\) subjected to a magnetic field of strength \(\vec {B}\) , this potential energy is given by43.
Averaging over the distribution of \(\vec {m}\) and using Eq. (2), one obtains
From Eq. (3) it is known that \(\langle \vec {M} \rangle\) and \(\vec {B}\) are parallel. This presents a challenge in magnetic guiding, as the dot product cancels the sign of the magnetic field, causing MPs to be constantly driven in the direction of regions with higher magnetic fields. This is completely analogous to paper clips being equally attracted by the south and north pole of a permanent magnet (never repelled!). However, it allows us to re-express Eq. (7) as (here \(\xi = \frac{M_\text {s}V}{k_\text {B}T}\,B\) is defined as in Eq. (2))
Compared to Eq. (6), this equation is much simpler, as it no longer requires the calculation of the complicated gradient tensor (as seen in Eq. (4)). Due to the loss of direction in the dot product of Eq. (3), the magnetic force now only depends on the rescaled strength of the magnetic field, \(\xi\), and its gradient \(\vec {\nabla }\xi\), a simple vector. However, we have introduced a new non-linear, material- and field-dependent function \(\mathfrak {P}(\xi )\), which accounts for the fact that the average magnetization depends on the magnetic field. It is often neglected by assuming \(\langle \vec {M}(\vec {B}) \rangle = \vec {M}_\text {s}\), i.e., \(\mathfrak {P}(\xi ) = 1\). We emphasize that \(\mathfrak {P}(\xi )\) differs from \(\mathfrak {L}(\xi )\) in Eq. (2). The reason is that the total force on the MPs in a magnetic field gradient has two contributions: the first is the direct averaged magnetic force on MPs with average magnetization \(\langle \vec {M}(\vec {B}) \rangle = \vec {M}_\text {s}\mathfrak {L}(\xi )\) (the first term in Eq. (8)), and the second is a thermodynamic force accounting for their drift to regions in space where their average magnetization would be energetically more favorable (the second term in Eq. (8)). A comparison of \(\mathfrak {L}(\xi )\) and \(\mathfrak {P}(\xi )\) is shown in Fig. 2. Both functions have a similar shape, but \(\mathfrak {P}(\xi )\) reaches saturation much more rapidly and is twice as steep at the origin.
Equation (9) shows that two conditions, \(|\vec {B}| \ne 0\) and \(\vec {\nabla }|\vec {B}| \ne 0\), must be fulfilled to enable magnetic steering of nanoparticles. Specifically, both the gradient of the field \(\vec {\nabla }|\vec {B}|\) and the field-induced average magnetization \(\langle \vec {M}(\vec {B}) \rangle\) must be non-zero. This complicates the characterization of magnetic systems in their ability to move MPs, because \(\langle \vec {M}(\vec {B}) \rangle\) depends on the nature of the used MP. The fact that the magnetic force is governed by \(\mathfrak {P}(\xi )\) rather than \(\mathfrak {L}(\xi )\), the function that describes the average magnetization of the particles, somewhat eases the problem. The average magnetization in Eq. (2) will only reach a constant for B-values close to saturation. However, the curve in Fig. 2 shows that concerning the resulting magnetic force, one may approximate almost constant behavior (\(\mathfrak {P}(\xi ) = 1\)) already at approximately 5 mT for MPs with a radius of \(r \approx 20\) nm.
Nevertheless, a local magnetic field must be present to magnetize the MPs, and it must have a strong gradient to exert a force on them.
Effective gradient and directionality
Given that magnetic guiding instruments need to be evaluated for their effectiveness, a comprehensive characterization would involve a three-dimensional description or dataset of their magnetic flux density. However, comparing different designs on that ground is rather impractical, and some simple descriptors are needed. Obviously, summarizing the information of a general vector field in just a few numbers is impossible. Even if it were possible, an exact prediction of the force magnitude generated by this magnetic field is not feasible without knowledge of the characteristics of the MPs to be used in the device. This is due to the non-linearity of Eq. (2) and the size-dependence of the magnetization, as illustrated in Fig. 2.
Nonetheless, it is highly desirable to extract some more meaningful quantities than, for instance, the maximal magnetic flux density and its maximal gradient. Therefore, we propose here to use a quantity that contains information on both the strength and the gradient of the field. This quantity, which we refer to as “effective gradient”, K, is defined by the expression:
where \(|\vec {B}|_\text {max} = \text {max}(B)\) is the maximal field strength in the sample volume. Equation (11) combines magnitude and gradient of the magnitude of the magnetic field. The normalization with \(|\vec {B}|_\text {max}\) has the advantage that K has the units of a field gradient [T/m] and multiplication with \(M_\text {s}V\) will give a rough estimate of the force that can be expected for a certain MP (assuming that \(|\vec {B}|_\text {max}\) is close to the saturation field strength). As discussed earlier, this does not replace a detailed analysis, but the average, minimal, and maximal value (and possibly its standard deviation) of \(|\vec {K}|\) in a specified sample volume should offer a good estimate of force distribution that can be expected in a magnetic system.
A second potentially important information on this magnetic vector field is the uniformity, \(\vec {U}\), of the direction of the generated magnetic force. We define it as
i.e., the integral (or, in case of discrete measurements, the sum) over all components of the effective gradient in Eq. (11), normalized by the volume (or the total number of discrete entries) and \(|K_{xyz}|^{(V)}_\text {max}\) which represents the maximal magnitude of all entries, n, of all components of \(|\vec {K}|\) in that volume. For instance, \(\vec {U} = (1,0,0)\) would indicate that the effective gradient points exclusively in the x-direction. Values less than one indicate non-uniformities in the directionality.
Experiment
To illustrate the key points of the prior discussion, we compare the magnetic fields of two distinct magnet designs acting on MPs like those discussed in Fig. 2. The first magnetic field is that of a Halbach quadrupole (cf. Fig. 3B) and the second is the same quadrupole combined with a Halbach dipole, forming an instrument called MagGuider44 (cf. Fig. 3C). The pure quadrupole design was chosen for its provision of strong and homogeneous gradients, commonly used in experiments involving magnetically manipulated MPs or MP-loaded cells45,46,47. However, the magnetic field at its center is weak (theoretically zero). Therefore, it is an ideal magnetic pattern to illustrate the difference between magnetic field gradients and force. The MagGuider-system is a combination of a quadrupole with a dipolar magnet, which additionally provides a homogeneous background magnetic field. It is designed to overcome the problem of low magnetic forces in certain regions. Since the homogeneous field ideally has no gradients (and only small gradients in reality), its combination with the quadrupole leads to almost identical field gradients for both systems. If the geometry is properly chosen (i.e., the condition \(B > Gr\) must be fulfilled at a distance r from the center, with B being the strength of the homogeneous dipolar field and G the constant gradient of the quadrupole), it produces a magnetic force field which is homogeneous both in magnitude and direction. The principle is explained elsewhere31,44. Both magnets are shown in Fig. 3. They were designed to generate rather low magnetic fields, to illustrate the problems associated with them.
Figures 4 and 5 show the magnetic properties of both magnet systems, derived from two dimensional measurements of the \(B_x\) and \(B_y\) component over the size of the utilized Petri dish. In both figures, the first three columns help to understand the spatial features of the vector field and its two components, however, for the discussion the last column of the magnitude is sufficient. In the case of the pure quadrupole system, Fig. 4H shows the gradient of the magnetic field magnitude in Fig. 4D (cf. discussion to Eq. (3)). This gradient is nearly constant, representing a high degree of homogeneity. However, the magnitude of the magnetic field, has radial dependence and is zero at the center as shown in Fig. 4D. As a consequence, the magnetization of the MPs and hence the magnetic force acting on them is very weak in the center with a strongly non-linear increase radially outwards (see Fig. 4L). This can be alleviated if larger MPs are used as discussed in the context of Fig. 2. The effective gradient is defined by Eq. (11) and shown in Fig. 4P. This figure shows similar features to \(|\vec {B}|\) in Fig. 4D (because its gradient is constant) but has units of a gradient. Hence, it represents the influence of the magnetic field on the force on any MP better than the field gradient (Fig. 4H) but overemphasizes the narrow central low field region in Fig. 4L for these particular MPs.
The magnetic properties of the MagGuider system (Fig. 3C) are portrayed in Fig. 5. Due to the superposition of the homogeneous gradient field (i.e. a linear changing magnetic field) of the quadrupole with the homogeneous magnetic field of the dipole, the negative field, the gradient, and hence force components in the y-direction are eliminated. Consequently, the MPs are guided exclusively in this direction (here upwards) of the magnet system. For this particular system, the “guiding condition” (\(B(\approx 8\,\text {mT}) \gg Gr(\approx 5.7\,\text {mT}))\)44 is just barely fulfilled. One can see stronger directional deviations to the sides for \(x \rightarrow \pm \,35\) mm, e.g. in Fig. 5I. Nevertheless, it has relatively high uniformity along the y-direction, \(\vec {U} = (-0.07,0.38)\), in particular in comparison to the quadrupole, where the uniformity is essentially zero. The presence of the homogeneous magnetic background field throughout the sample volume results in much less variation of the spatial features of G, K, and F than in the pure quadrupole system (cf. second to forth row in Fig. 5), as intended by the MagGuider design principle. Figure 6 provides examples of the distribution of 10 nm superparamagnetic iron-particles dispersed in light mineral oil and suspended on water at different times after exposure to the magnetic field of the quadrupole (Figs. 3B, 4) and the MagGuider (Figs. 3C, 5). This qualitative representation illustrates the interaction of the particles with the magnetic field of the two devices. In the MagGuider system, the initially uniformly distributed MPs in Fig. 6A concentrate within one second in the direction of the magnetic force (Fig. 6B). Conversely, in the pure quadrupole, a fraction of particles initially moves (cf. Fig. 6C) towards the four poles, while a substantial portion remains in the center (“cross- shaped” feature in Fig. 6C), since the magnetic field (not the bare gradient) is much smaller there. In equilibrium (Fig. 6D), the ferrofluid concentrates at large radii, with a distribution that is mostly independent of the angle. This state is reached after approximately ten seconds. Note that, just from inspecting the forces acting on the individual MPs (cf. Table 2), one would not expect such a rapid motion. However, the velocity is not only determined by the force, but also by the hydrodynamics and the morphology. Due to the phase separation of water and ferrofluid, larger drops behave collectively (like a big particle) and slide with very low friction on top of the water surface.
To conduct a more quantitative analysis, water-soluble superparamagnetic nanoparticles48 were used. The results are summarized in Fig. 7. Images of these particles dispersed in water were captured over a period of more than 70 hours inside the quadrupole of Fig. 3B. The first image on the left shows half of the Petri dish at time \(t = 0\) (initial distribution), the subsequent shows a central slice at different times as indicated, and the last one the final distribution in the entire Petri dish. From the slices it can be recognized that the initial brownish color of the dispersion becomes brighter with time as more and more particles are pulled towards the rim. This happens much faster in the case of the MagGuider systems, as shown in Fig. 7B (same mode of presentation). Please note the very different time scale in both figures. In the final state the particles end up at the entire rim in the case of the pure quadrupole, and at the top rim (indicated by the blue arrow) in the case of the MagGuider as already shown in Fig. 6.
In order to analyze this more quantitatively, the intensity of a central region of each image was integrated and normalized with respect to an image of the empty Petri dish and the intensity of the initial particle concentration. Figure 7C shows the results, which were fitted by a double exponential decay. The fast decay is attributed to the pull exerted on the nanoparticles by magnetic forces. The slower decay reflects the motion of some remaining slower particles, which might be slowed down by interactions with the bottom of the dish, or—in the case of the quadrupole, an unfavorable trajectory: particles that initially stay in the low field in the center first have to diffuse into a regions with stronger magnetic forces (diffusing water needs ca. 2200 min or 37 h to cover a distance of 35 mm). Both the the initial fast intensity decay and the subsequent slower decay are nearly an order of magnitude more rapid for the MagGuider system, even though the gradients are almost identical in both systems (cf. Table 2).
In Table 2, we attempt to characterize the relevant properties of both magnetic systems by the descriptive numbers discussed above, namely, \(|\vec {B}| = B\), \(|\vec {G}| = G\), and \(|\vec {K}| = K\), and test their use for predicting the magnetic force on the two different particles used in Figs. 6 and 7. The most obvious discrepancy arises from the much lower force measured for the smaller particles (\(r = 5\) nm) used in Fig. 6. Here the predictions via \(M_\text {s}V\,|\vec {G}|\) or \(M_\text {s}V\,|\vec {K}|\) deviate by one or two orders of magnitude from the calculated force for both magnet systems. This is because the magnetic field in both systems is too low to fully magnetize the MPs, and resulting in \(\overline{\mathfrak {P}}(\xi ) = 10^{-3}\) for the quadrupole and \(\overline{\mathfrak {P}}(\xi ) = 0.02\) for the MagGuider (where \(\overline{\mathfrak {P}}(\xi )\) is the averaged value in Table 2). This illustrates the importance of knowing the local magnetic fields. The predictions using \(M_\text {s}V\,|\vec {K}|\) instead of \(M_\text {s}V\,|\vec {G}|\) are slightly better, but still differ from \(|\vec {F}| = F\), in particular when looking at the minimum value. The same holds for the larger particles (\(\overline{\mathfrak {P}}(\xi ) \approx 1\)), where the value of \(M_\text {s}V\,|\vec {G}|\) is identical with the force for the MagGuider, but again overestimate the minimal force by an order of magnitude for the quadrupole. The best description is realized by giving the range of all three quantities B, G, and K, the latter because it connects the local information on the other two. Without this information (e.g., by only giving the gradient strengths of the systems, which are close to identical for both of them), the very different behavior of MPs as in Fig. 7C can neither be explained nor predicted.
Discussion
In the application of magnetic systems for magnetic guiding, it is crucial to have a standardized characterization and description. This not only aids in comprehending, interpreting, comparing, and replicating results, but also provides a more comprehensive assessment than relying on the maximal field gradient alone. This is because both the thermally averaged magnetization and the field gradient contribute to the overall force. While the average magnetization is an inherent material property of the used MPs, it is also dependent on the magnetic field strength. Consequently, both the magnitude of the magnetic flux and its gradient are essential in evaluating a device’s capacity to exert a force on MPs. This is illustrated by two magnet systems, that possess similar gradient strengths but exhibit a tenfold difference in their ability to move MPs. Therefore, we propose to introduce a different quantity termed ‘effective gradient’, which describes the joint spatial characteristics of \(|\vec {B}|\) and \(\vec {\nabla }|\vec {B}|\). The spatial distribution of this “effective gradient” can provide a rough estimate of the generated magnetic force and can be approximated using typical descriptors of distributions like average, standard deviation, minimum, and maximum over the volume of interest. Additionally, providing information about the magnetic field and gradient separately can further enhance characterization. Furthermore, the orientational homogeneity of the force can be described by a directionality vector. We hope that these suggestions will facilitate a better comparison of instruments designed for magnetic guiding. Consequently, the aim in designing such instruments must be to maximize (and possibly homogenize) \(|\vec {K}(\vec {r})|\) in the volume of interest. Of course the gold standard of providing a detailed description of \(\vec {B}(\vec {r})\) (i.e. 6 dimensional data sets from measurements or simulations) is not replaced by this single entity, but it still gives a better assessment on the capability of an instrument to generate a magnetic force on MPs than the maximal field gradient.
Although magnetic forces acting on single nanoparticles are in the sub-attonewton regime and might appear extremely low, they are sufficient to induce aggregate formation depending on the coating and concentrations of MPs due to the attraction via dipole forces. The force on such an aggregate is then the multiple of the force on a single MP, scaled by the number of particles in the aggregate (cf. the ferrofluid drops in Fig. 6).
This underscores that even knowing the magnetic force alone is insufficient to fully describe the ability of a system for magnetic guiding, because it is the motion of the MPs, which is of interest. The relevant quantities are the velocity and acceleration of the MPs. To determine them becomes a hydrodynamical problem, which can be described by Stokes’ law for MPs or MP aggregates in liquids (for details and the hydrodynamics of aggregates see31. In addition, Hooke’s law applies in elastic, isotropic solids, and theories of viscoelasticity come into play in complex fluids like polymer or protein solutions. Consequently, local factors such as MP concentration, and rheological characteristics of the surrounding medium such as viscosities or moduli are needed to predict the particle motion from the force field. In the complex and heterogeneous environment of biological tissues, simulations, ideally assisted by experiments, are required to predict the forces needed to induce the intended motion.
Materials and methods
The magnets depicted in Fig. 3 are constructed using cubic permanent neodymium magnets (Nd2Fe\(_{14}\)B) affixed into 3D printed supports (polylactic acid). Specifically, the quadrupole is assembled from 16 cubic magnets with 8 mm side length (N45, \(B_\text {R} = 1.35\) T) obtained from magnets4you GmbH, 97816 Lohr, Germany. Their centers are mounted in a circle with a radius \(r = 67.5\) mm.
The dipole consists of 32 magnets (10 mm cubes, N45, \(B_\text {R} = 1.35\) T) purchased from dogeo GmbH, 55444 Waldlaubersheim, Germany, and mounted in a circular arrangement with \(r = 87\) mm.
The magnetic field components in Figs. 4 and 5 were measured with a Hall-probe sensor (HMNT-4E04-VR, Lake Shore Cryotronics Inc., Westerville, OH) mounted on a computer-controlled 3D linear table (OWIS GmbH, Staufen im Breisgau, Germany) and controlled by custom-written software. A circular area with a radius of 36 mm was scanned with a step width of 1 mm in x and y direction.
The MPs used in the qualitative display shown in Fig. 6 are 10 nm are iron particles (EFH1, \(M_\text {s} = 32\) kA/m) dispersed in light mineral oil, acquired from FerroTec, Santa Clara, CA.
The MPs used in the experiments for Fig. 7 are 130 nm nanomag-D with plain surfaces (product no. 09-00-132) from micromod, Rostock, Germany. They are multicore iron oxide particles (\(M_\text {s} = 120\) kA/m) consisting of several smaller magnetic particles48.
References
Munoz, F., Alici, G., Weihua Li, H. Z. & Sitti, M. Analysis of magnetic interaction in remotely controlled magnetic devices and its application to a capsule robot for drug delivery. IEEE/ASME Trans. Mechatron. 23, 298 (2018).
Swain, P. The future of wireless capsule endoscopy. World J. Gastroenterol. 14, 4142 (2008).
Sun, Y., Yu, J. & Wang, X. Field-Driven Micro and Nanorobots for Biology and Medicine (Springer, 2022).
Koleoso, M. et al. Micro/nanoscale magnetic robots for biomedical applications. Mater. Today Bio 8, 100085. https://doi.org/10.1016/j.mtbio.2020.100085 (2020).
Yang, Z. & Zhang, L. Magnetic actuation systems for miniature robots: A review. Adv. Intell. Syst. 2000082, 1–18 (2020).
Shao, Y. et al. Study on magnetic control systems of micro-robots. Front. Neurosci. 15, 736730. https://doi.org/10.3389/fnins.2021.736730 (2021).
Shapiro, B. et al. Open challenges in magnetic drug targeting. WIREs Nanomed. Nanobiotechnol. 7, 446–457. https://doi.org/10.1002/wnan.1311 (2015).
Tietze, R. et al. Magnetic nanoparticle-based drug delivery for cancer therapy. Biochem. Biophys. Res. Commun. 468, 463–470. https://doi.org/10.1016/j.bbrc.2015.08.022 (2015).
Attia, M. F., Anton, N., Wallyn, J., Omran, Z. & Vandamme, T. F. An overview of active and passive targeting strategies to improve the nanocarriers efficiency to tumour sites. J. Pharm. Pharmacol. 71, 1185–1198. https://doi.org/10.1111/jphp.13098 (2019).
Dobson, J. & Rinaldi, C. Nanomagnetic Actuation of Cell Surface Receptors: Basic Principles and Applications (CRC Press, 2018).
Rajan, A. & Sahu, N. Review on magnetic nanoparticle-mediated hyperthermia for cancer therapy. J. Nanopart. Res. 22, 319. https://doi.org/10.1007/s11051-020-05045-9 (2020).
Obaidat, I. M., Issa, B. & Haik, Y. Magnetic properties of magnetic nanoparticles for efficient hyperthermia. Nanomaterials 5, 63–89. https://doi.org/10.3390/nano5010063 (2015).
Day, N. B., Wixson, W. C. & Shields, C. W. IV. Magnetic systems for cancer immunotherapy. Acta Pharm. Sin. B 11, 2172–2196. https://doi.org/10.1016/j.apsb.2021.03.023 (2021).
Chansoria, P., Liu, H., Christiansen, M. G., Schürle-Finke, S. & Zenobi-Wong, M. Untethered: Using remote magnetic fields for regenerative medicine. Trends Biotechnol. 41, 615–631. https://doi.org/10.1016/j.tibtech.2022.09.003 (2023).
Bongaerts, M. et al. Parallelized manipulation of adherent living cells by magnetic nanoparticles-mediated forces. Int. J. Mol. Sci.https://doi.org/10.3390/ijms21186560 (2020).
Plen, R. et al. Bioengineering 3d neural networks using magnetic manipulations. Adv. Funct. Mater. 32, 2204925. https://doi.org/10.1002/adfm.202204925 (2022).
De Vincentiis, S. et al. Extremely low forces induce extreme axon growth. J. Neurosci. 40, 4997–5007. https://doi.org/10.1523/jneurosci.3075-19.2020 (2020).
Dhillon, K. et al. Directional control of neurite outgrowth: Emerging technologies for Parkinson’s disease using magnetic nanoparticles and magnetic field gradients. J. R. Soc. Interface 19, 20220576. https://doi.org/10.1098/rsif.2022.0576 (2022).
Parfenov, V. A. et al. Magnetic levitational bioassembly of 3d tissue construct in space. Sci. Adv. 6, eaba4174. https://doi.org/10.1126/sciadv.aba4174 (2020).
Lee, E. A. et al. Application of magnetic nanoparticle for controlled tissue assembly and tissue engineering. Arch. Pharm. Res. 37, 120. https://doi.org/10.1007/s12272-013-0303-3 (2014).
Friedrich, R., Cicha, I. & Alexiou, C. Iron oxide nanoparticles in regenerative medicine and tissue engineering. Nanomaterials 11, 2337. https://doi.org/10.3390/nano11092337 (2021).
Goranov, V. et al. 3d patterning of cells in magnetic scaffolds for tissue engineering. Sci. Rep. 10, 2289. https://doi.org/10.1038/s41598-020-58738-5 (2020).
Hauser, A. K., Wydra, R. J., Stocke, N. A., Anderson, K. W. & Hilt, J. Z. Magnetic nanoparticles and nanocomposites for remote controlled therapies. J. Control. Release 219, 76–94. https://doi.org/10.1016/j.jconrel.2015.09.039 (2015).
Etoc, F. et al. Subcellular control rac-gtpase signalling by magnetogenetic manipulation inside living cells. Nat. Nanotechnol. 8, 193–198. https://doi.org/10.1038/nnano.2013.23 (2013).
Raudzus, F. et al. Magnetic spatiotemporal control of sos1 coupled nanoparticles for guided neurite growth in dopaminergic single cells. Sci. Rep. 10, 22452. https://doi.org/10.1038/s41598-020-80253-w (2020).
Lee, J. U. et al. Non-contact long-range magnetic stimulation of mechanosensitive ion channels in freely moving animals. Nat. Mater. 20, 1029–1036. https://doi.org/10.1038/s41563-020-00896-y (2021).
Zahn, M. Magnetic fluid and nanoparticle applications to nanotechnology. J. Nanopart. Res. 3, 25 (2001).
Panina, L. V. et al. Spatial manipulation of particles and cells at micro- and nanoscale via magnetic forces. Cells 11, 950. https://doi.org/10.3390/cells11060950 (2022).
Garello, F., Svenskaya, Y., Parakhonskiy, B. & Filippi, M. Micro/nanosystems for magnetic targeted delivery of bioagents. Pharmaceutics 14, 1132. https://doi.org/10.3390/pharmaceutics14061132 (2022).
Andrä, W. & Nowak, H. Magnetism in Medicine: A Handbook (Wiley, 2007).
Blümler, P. Magnetic guiding with permanent magnets: Concept, realization and applications to nanoparticles and cells. Cells 10, 2708. https://doi.org/10.3390/cells10102708 (2021).
Cao, Q. L. et al. Recent advances in manipulation of micro- and nano-objects with magnetic fields at small scales. Mater. Horiz. 7, 638–666. https://doi.org/10.1039/c9mh00714h (2020).
Komaee, A. & Shapiro, B. Steering a ferromagnetic particle by optimal magnetic feedback control. IEEE Trans. Contr. Syst. Technol. 20, 1011–1024. https://doi.org/10.1109/TCST.2011.2152842 (2012).
Sliker, L., Ciuti, G., Rentschler, M. & Menciassi, A. Magnetically driven medical devices: A review. Expert Rev. Med. Devices 12, 737–752. https://doi.org/10.1586/17434440.2015.1080120 (2015).
Liu, Y. L., Chen, D., Shang, P. & Yin, D. C. A review of magnet systems for targeted drug delivery. J. Control. Release 302, 90–104. https://doi.org/10.1016/j.jconrel.2019.03.031 (2019).
Knopp, T. & Buzug, T. M. Magnetic Particle Imaging: An Introduction to Imaging Principles and Scanner Instrumentation (Springer, 2012).
Krishnan, K. M. Fundamentals and Applications of Magnetic Materials (Oxford University Press, 2016).
Bean, C. P. & Livingston, J. D. Superparamagnetism. J. Appl. Phys. 30, 120S-129S (1959).
Kemgang, E. & Messina, R. Columnar dipolar clusters defying gravity. Phys. Rev. E 105, L012602. https://doi.org/10.1103/PhysRevE.105.L012602 (2022).
Odenbach, S. Colloidal Magnetic Fluids: Basics, Development and Application of Ferrofluids, vol. 763 of Lecture Notes in Physics (Springer, 2009).
Caizer, C. & Rai, M. Magnetic Nanoparticles in Human Health and Medicine: Current Medical Applications and Alternative Therapy of Cancer (Wiley Blackwell, 2022).
Bender, P. et al. Relating magnetic properties and high hyperthermia performance of iron oxide nanoflowers. J. Phys. Chem. C 122, 3068–3077. https://doi.org/10.1021/acs.jpcc.7b11255 (2018).
Jackson, J. D. Classical Electrodynamics (Wiley, 1975).
Baun, O. & Blümler, P. Permanent magnet system to guide superparamagnetic particles. J. Magn. Magn. Mater. 439, 294–304. https://doi.org/10.1016/j.jmmm.2017.05.001 (2017).
Riggio, C. et al. The orientation of the neuronal growth process can be directed via magnetic nanoparticles under an applied magnetic field. Nanomed. Nanotechnol. Biol. Med. 10, 1549–1558. https://doi.org/10.1016/j.nano.2013.12.008 (2014).
Dziob, D., Ramian, J., Ramian, J., Lisowski, B. & Laska, J. Design and construction of a chamber enabling the observation of living cells in the field of a constant magnetic force. Cells 10, 3339. https://doi.org/10.3390/cells10123339 (2021).
Babincova, M. & Babinec, P. Magnetic drug delivery and targeting: Principles and applications. Biomed. Pap. Olomouc 153, 243–250. https://doi.org/10.5507/bp.2009.042 (2009).
Eberbeck, D. et al. Multicore magnetic nanoparticles for magnetic particle imaging. IEEE Trans. Magn. 49, 269–274. https://doi.org/10.1109/tmag.2012.2226438 (2013).
Acknowledgements
We wish to thank Rudolf Zentel (University of Mainz) and Matthias Barz (University of Leiden) for inspiring this work. Rolf Heumann (University of Bochum) has to be acknowledged for helpful discussions and suggestions regarding this manuscript. This work has been supported by the Deutsche Forschungsgemeinschaft funded Collaborative Research Center “Nanodimensional polymer therapeutics for tumor therapy”-SFB 1066 , (DFG Grant number 213555243). Further, we thank JSPS-KAKENHI (Grant number 22K06430, F.R.) for the support.
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Contributions
P.B. build the magnets and performed the experiments, otherwise all authors equally contributed to the manuscript and its revisions.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Blümler, P., Raudzus, F. & Schmid, F. A comprehensive approach to characterize navigation instruments for magnetic guidance in biological systems. Sci Rep 14, 7879 (2024). https://doi.org/10.1038/s41598-024-58091-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-024-58091-x
Keywords
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.