Abstract
State-of-the-art high-throughput microscopes are now capable of recording image data at a phenomenal rate, imaging entire microscope slides in minutes. In this paper we investigate how a large image set can be used to perform automated cell classification and denoising. To this end, we acquire an image library consisting of over one quarter-million white blood cell (WBC) nuclei together with CD15/CD16 protein expression for each cell. We show that the WBC nucleus images alone can be used to replicate CD expression-based gating, even in the presence of significant imaging noise. We also demonstrate that accurate estimates of white blood cell images can be recovered from extremely noisy images by comparing with a reference dictionary. This has implications for dose-limited imaging when samples belong to a highly restricted class such as a well-studied cell type. Furthermore, large image libraries may endow microscopes with capabilities beyond their hardware specifications in terms of sensitivity and resolution. We call for researchers to crowd source large image libraries of common cell lines to explore this possibility.
Similar content being viewed by others
Introduction
Optical microscopy is a core data gathering technique in the biological sciences. Digital microscopes enable researchers to record and store cellular scale images for further analysis offline1,2,3. Recent development of high throughput, gigapixel-scale microscopes4,5,6,7,8,9 have enabled collection of large datasets of cellular images. Once recorded, image processing routines turn this raw image data into quantifiable data, which can be used to aid diagnoses10 or to draw experimental conclusions3,11,12.
Often, the goal of a biological microscopy experiment isn’t to record the images themselves, but rather, to produce a low-dimensional quantification of the images3,11,12. While the input (the images) may contain a large amount of data, the output (abundance of each cell type, for example) takes the form of only a handful of scalar values. This mismatch suggests that there is a way to compress the input by using some a priori information about the cells. A compression of the input results in a faster image recording process, and decreased impact of phototoxicity and photobleaching. The type of a priori information used depends on the nature of the images. In cellular imaging experiments, one is often concerned with a restricted class of cells. These cells might differ slightly from one another in morphology, but they will share common features13,14,15,16,17. Armed with a reference library of typical cell images and associated properties, we may expect to be able to computationally reconstruct information about a cell from a severely undersampled or noise-corrupted input image18,19,20,21,22.
In this paper we explore how to leverage a large collection of reference images to enhance imaging cytometry. We use a high-throughput microlens array microscope4,6,7 to image and catalogue over 260,000 white blood cells (WBCs). WBCs are fluorescently labelled with a nuclear dye together with fluorescently tagged CD15 and CD16 markers. Cells are then mounted on a microscope slide for imaging. Individual cell images are extracted from raw fluorescence images using standard thresholding and segmentation approaches. Using CD15 and CD16 expression levels in each cell image, we show that the WBC population is divisible into 4 distinct populations, each with distinct nuclear morphologies. These populations are then gated to produce large dictionaries of nuclear morphology, which can in turn be explored. We demonstrate that these nuclear morphology dictionaries can be used to perform classification using only a fluorescence image of the nuclear shape. Moreover, this dictionary-based approach performs surprisingly well even in the presence of significant simulated imaging noise. This observation suggests that classification or quantification of cells in fluorescence microscopy can be done at low light levels given a library of example images that captures the full range of variability in cellular structure. Finally, we demonstrate dictionary-based denoising of nuclear morphology. We show that nuclear morphology can be accurately recovered from noisy images – even when the signal falls below the noise floor. This last result suggests a data-driven approach for ultra low light imaging. We discuss extensions of this idea, where crowd sourced high-resolution, multidimensionsal (3D, spectral, etc.) image dictionaries are used to enhance the capabilities of more rudimentary, cheaper microscopes.
Results
Imaging
We employ a high-throughput microlens microscope to image cm-scale areas of microscope slides, which are covered with fluorescently labelled WBCs as shown in Fig. 1a. This image covers an area of 1.7 × 1.1 cm at a sampling density of 0.5μm/pixel for a total size of ~0.75 gigapixels. We use 3 different fluorescent dyes to highlight the nuclei and quantify protein expression. Nuclei are dyed with Syto 16 (blue), while allophycocyanin (APC, green) and Brilliant Violet 421 (red) indicate CD15 and CD16 density, respectively. The microlens microscope operates like a highly parallelized point scanning microscope, producing an array of small sub-images – one for each microlens. When imaging continuous objects, these neighbouring sub-images are stitched together. However, because our goal is to build up a library of WBC images, we do not stitch sub-images from neighbouring microlenses. Instead, we apply a thresholding and segmentation routine to the Syto 16 channel for each sub-image independently in order to extract individual white blood cell nucleus images (Fig. 1b,c). Each WBC nucleus image identified by this process is entered into an array that makes up the library. The expression levels for CD15 and CD16 are calculated by summing the appropriate fluorescence channel within the WBC nucleus segmentation mask. An area normalized CD density can also be calculated, if desired. Segmenting only the nucleus as opposed the entire cell avoids ambiguity resulting from touching and overlapping cell membranes. White blood cell nuclei rarely overlap as they are well separated by the cytoplasm.
Using the WBC nucleus segmentation approach described in Methods, we extract 260,676 WBC nucleus images. Each nucleus image is 26 × 26 pixels in size (13 × 13 μm), with a CD15 and CD16 expression value for each cell. The entire set of extracted images is included as Supplementary Data 1. To aid in dataset exploration, we calculate a circularity parameter C for each WBC nucleus in the library . where A is the nuclear area and P is the nuclear perimeter. Figure 2 shows a snapshot of the roughly 0.5% of the entire WBC library (1,225 of 260,676 cells), organized least to most circular from left to right (low to high C). With this ordering one can quickly appreciate the diversity of WBC nuclear shapes present in the library. Indeed, other orderings, such as by eccentricity, total area or CD expression are also possible.
Classification
In this section we show that nuclear morphology can be used directly to classify WBCs. We first identify 4 distinct gates emergent from our CD15/CD16 labelling approach. These gates are then split into dictionary and trial sets for correlation-based classification.
Four distinct clusters are visible upon displaying a subset (see Gating in Methods) of the cellular CD15/CD16 expression data as a log-scale dotplot (Fig. 3). We gate each one of these clusters manually into gates labelled R1-R4. A sampling of the nuclear images in each gate is shown in the insets to Fig. 3. We will refer to the entire set of nuclear images in gates R1-R4 as the reference library. The reference library is composed of 23,894 R1; 3,583 R2; 1,685 R3; and 517 R4 images.
One can clearly see the distinctive multi-lobed nuclei characteristic of neutrophils in R123. The population in gate R2 is likely dominated by lymphocytes, as evidenced by the small circular nuclei found in R2. Nuclei in R3, most likely belonging to a CD16- monocyte population, are slightly bigger and less circular than those in R224. Finally, there is a small number of large, highly expressing CD15++ cells in gate R4. These cells are possibly undifferentiated granulocytes, however, further investigation is necessary for unambiguous identification. Other types of less common WBCs such as basophils, eosinophils and natural killer cells will be found throughout these gates24, but are unresolvable with our two-dimensional CD15/CD16 labelling strategy.
Next, we implement an image-matching WBC classification scheme. The approach is as follows. From each gate, we remove 100 cells from the reference library to construct a trial image set. The remaining reference images we refer to as the dictionary. We then proceed to classify each cell in the trial set as belonging to one of R1-R4 based solely on the magnitude of the cross-correlation with nuclear images from the dictionary. By knowing the ground truth gate of each cell in the trial set, we can quantify the accuracy of the classification scheme. Each of the images in the trial set is cross-correlated with each of the images in the reference set (across all gates), yielding a matrix image correlation values. Cross-correlation values range from 0 to 1, with 1 indicating a perfect match, and 0 signifying no similarity. For each cell in the trial set, a portion of the top correlation values for each cell type (R1-R4) is averaged, yielding a similarity index for each cell type. The optimal number of top correlation values to include in this average depends on the dictionary size and morphology variation (see Supplementary Note 4 and Supplementary Figures 1–3). The trial cell is classified as being of the cell type with the highest similarity index value.
Examples of trial cells and their 10 most highly correlated reference cells of each type are shown in Fig. 4. Note that while there are sometimes closely matching images for incorrect cell types, usually there are too few reference cells of the wrong type with high correlation values to result in a false classification. This feature makes our method robust against poorly classified reference data. A pair of examples of incorrect matches between R1 and R3 gates is also shown in Fig. 4. We comment on the nature of the crosstalk between these gates below. The entire distribution of correlation values for the correctly classified trial cells in Fig. 4 are shown in Supplementary Figure 4. Another way of looking at the correlation data is shown in Supplementary Figures 5–7, where we plot the decrease in correlation value in order of the correlation ranking.
To evaluate the accuracy of our classification algorithm, we applied the algorithm to 50 random permutations of trial sets and dictionaries. To calculate the cell similarity indices, we averaged the correlation values for the top m = 17 matches for R1, R2 and R4 dictionaries, while the R3 cell similarity index was obtained by averaging over the top m = 9 matches in the R3 dictionary. The number of top matches used (m), to calculate the cell similarity index for each dictionary (m = 17 for R1, R2, R4 and m = 9 for R3), was arrived at by calculating the overall classification accuracy for different numbers of top matches as outlined in Supplementary Note 4 and Supplementary Figure 1. Classification results are displayed as a confusion matrix in Table 1. Cells from gates R1, R2 and R4 are classified with over 90% accuracy. Cells from gate R3, however are classified correctly at a lower rate of 85.26%. Overall, 90.15% of trial cells are correctly classified. For comparison, the classification accuracy using a quadratic discriminant analysis (QDA)25, with a 5-dimensional feature vector (cell nucleus area, perimeter, circularity, eccentricity and solidity) is shown in Supplementary Table 4. The overall classification accuracy of this more traditional approach is 85.31%, nearly 5% less than with the dictionary-based approach. The dictionary-based method performs similarly to QDA for R2-R4 cells, but greatly outperforms QDA for R1 cell classification: 90.06% vs. 63.04% for dictionary-based and QDA, respectively.
We note that the lower classification accuracy of R3 is likely a result of monocytes being present in both R3 and R1 gates. It is well known that there is a ~10–20% non-classical CD16+ monocyte population in in the peripheral blood of a healthy donor26. Assuming these CD16+ monocytes have similar nuclear morphology to CD16- monocytes, they will result in cross talk between the R1 and R3 gates. This would happen both due to CD16+ monocytes in R1 matching with CD16- monocytes is R3, and vice-versa.
We applied the classification algorithm to a subset of 82,000 cells from our dataset. This subset is roughly 38% of the entire dataset and does not include any dictionary cells. The results are visualized in a color-coded dotplot in CD15/CD16 expression space, where at each datapoint we display a typical WBC nucleus image with the appropriate CD15 and CD16 expression (Fig. 5a). A larger version of this image available online allows the user to zoom in to discover the nuclear morphology in CD15/CD16 expression space27. Typical regions within R1-R4 gates are shown at a larger magnification in Fig. 5b–e. Of this 82,000 trial cell set, 66.91% are classified as R1, 25.07% as R2, 6.09% as R3 and 1.93% as R4. The proportions of R1, R2 and R3 classified trial cells are roughly in line for the expected abundance of neutrophils, lymphocytes and monocytes in peripheral blood28,29. Roughly 15% of the cells classified as R3 are located within the R1 gate. This matches well to the known normal range for the percentage of CD16+ monocytes in peripheral blood26, lending weight to our hypothesis that the R1/R3 crosstalk is due to a CD16+ monocyte population.
Typical approaches to cell classification rely on segmentation followed by extracting morphological features such as area, perimeter and curvature. However, these procedures become increasingly difficult to perform in noisy conditions. In contrast, our method avoids the need for precise segmentation and feature extraction by performing the classification process by direct image correlation with a low-noise reference set. We simulate this process by adding Gaussian noise to trial image sets in post-processing prior to cell classification. Classification results for a trial image set with a signal-to-noise-ratio (SNR) =3.5 are shown in Table 2. Even in the presence of significant noise, R2 and R4 cells are still classified with over 91% accuracy, while R1 and R3 cells are classified with 85.90% and 77.36% accuracy, respectively. At this low SNR, there is only a minor drop in the overall classification accuracy from the SNR = 90 case: 90.15% to 86.97%. The optimal number of top matches to include in calculation for the cell similarity indices was significantly larger than in the SNR = 90 case. For optimal classification at SNR = 3.5, we averaged over the top (69, 81, 21, 9) correlation values for (R1, R2, R3, R4) dictionaries to calculate the cell similarity indices (see Supplementary Figure 2).
The classification results in Table 2 are compared to QDA classification on the same noisy data in Supplemental Table 2. Our image matching approach matches or outperforms QDA for all cells types. The largest difference is for R1 cells, where the classification accuracy using segmentation and QDA on noisy images drops to 57.28% compared with 85.90% with image correlation. This large performance gap is a result of unreliable segmentation under noisy imaging conditions. The overall classification accuracy for SNR = 3.5 data is 86.97% with the dictionary-based method, compared to 75.67% using QDA. The performance gain of the dictionary-based method is even more pronounced for extremely low SNR values. Supplemental Tables 3 and 4 show that the dictionary-based method still retains an accuracy of 78.22% at a SNR = 1.75 in comparison to 57.46% using QDA. Comparisons for lower SNR values were not feasible due to unreliable image segmentation required to calculate the morphological features for QDA.
Denoising
In addition to high classification accuracy at low SNR values, the reference library also provides a means of denoising. By simply taking the average over the most highly correlated cells in the entire nuclear image dictionary, we can construct denoised estimate of the original image. To increase the size of the library, thereby increasing the likelihood of good dictionary matches, we also include copies of each cell rotated in 30° intervals over 360°. In this case there are over 3 × 106 cell nucleus images in the dictionary.
In Fig. 6, we show two examples of denoising for R1 cells where we simulate noisy imaging in post-processing. Cell nucleus images are corrupted with Gaussian noise of fixed variance, while the signal (ie. the pixel values of the original images) is scaled down, resulting in images with low SNR. Noise corrupted images are shown under columns labelled “N” in Fig. 6, and the ground truth images (pre-noise corruption) are found in the “GT” column. The top 10 dictionary matches are also indicated. The estimated cell image, resulting from averaging over the top 10 dictionary matches is shown in the “E” column. There is little change in the estimated cell image from SNR = 90 (the original cell nucleus image with no extra noise) down to 0.5. Remarkably, the de-noised estimates still reveal the general structure of the cell nucleus in cases where the signal is buried below the noise level. Estimates become increasingly unreliable below this level. This result is made possible because of a highly restricted set of WBC nuclear images and the large dictionary set. Image details below the noise floor consistently lead to appropriate matches given a suitable dictionary.
Discussion
We have demonstrated an approach to data-enhanced WBC cell classification and image denoising. Our direct image correlation approach maintains high cell classification accuracy even in the presence of high noise. Moreover, we are able to obtain morphologically accurate denoised estimates of WBC nucleus images below the noise floor at an SNR = 0.5, which is 180-fold lower than the SNR of the original dataset. When fixed detector noise is the dominant form of signal corruption, recovering an acceptable image from a 180-fold lower SNR in principle allows for a 180x higher frame rate or 180x less excitation dose (assuming read-noise dominated imaging). The latter is of utmost importance when imaging live cells or sparsely labelled samples. Decreased irradiation is also critical in x-ray computed tomography (CT) imaging. Our results suggest that a similar dictionary based approach may be valuable in other imaging fields and need not be confined to fluorescence microscopy of WBCs. We note that in our denoising and noisy classification simulations, noise was added after initial cell localization. A real low-light experiment will not have this luxury and will require precise identification of cell positions within noisy microscope images. This is a similar problem to localization of single molecule fluorescence in super resolution techniques30, which can be achieved in the presence of significant noise.
Though we have applied our technique to WBCs, we expect that the direct image correlation method we present here will be applicable to a wide variety of cell types when paired with large image libraries. Experiments involving standard cell lines that are used widely in the scientific community may benefit significantly from this approach. For example, an image library of HeLa cells15,31,32 might enable extremely low excitation intensity fluorescence imaging of this model cell line, thereby sidestepping limitations arising from photobleaching and phototoxicity.
Given the widespread use of certain cell lines, it should be possible to build up massive image databases by crowd sourcing the library collection task. Such a freely available database would have implications beyond what we have demonstrated with classification and denoising applications. Using our data-driven approach, researchers with low-resolution imaging hardware might be able to use a high-resolution image database to estimate a super-resolved version of their data. Researchers may be able to estimate cellular structure across dimensions as well. If a large 3D reference set (eg. confocal image stack) of cell type were available, a 2D slice of a trial cell could be sufficient to locate a match in the reference set, thus obtaining an estimate for 3D structure of the cell. Ultimately, such imaging estimates are only useful if they are able to predict a certain property of a cell, such as its protein expression or metabolic state. We have demonstrated this by showing that image-based classification can reproduce manual gating of CD15/CD16-labeled WBCs.
Constructing appropriately large reference libraries is a time consuming task best suited to high throughput microscopes, such as the one employed in this work or imaging flow cytometers33. As these speciality hardware systems become more widely available, users will have the opportunity to assemble open source image libraries to be shared amongst the scientific community. Those without access to high throughput systems could then use these libraries as references for a priori data-enhanced operations such as cell classification, denoising. In this vein, we are releasing the reference libraries acquired for this work, as Supplementary Data 1. The image sets are also available in a web friendly format on Gigapan27,34,35. We encourage researchers to explore the images in this dataset, and in particular to observe the fascinating array of nuclear shapes in the complete dataset.
Methods
Slide preparation
Microscope coverslips (#1) used for sample imaging were prepared by applying a thin layer of 0.5% porcine gelatin, air dried, and then rinsed with water. A thin layer of 1% BSA in PBS was then applied to the porcine layered coverslips, air dried, and rinsed with water.
White Blood Cell Isolation and Staining
10 ml EDTA preserved fresh blood drawn 1–2 hours prior to cell preparation was purchased from Research Blood Components, LLC (Brighton, Ma). Red blood cells were removed for the sample using a RBC lysis buffer protocol provided by the company (Alfa Aesar), leaving the white blood cell population whole and intact. The final white blood cell concentration was adjusted to 1 × 106 in 100 μl for each slide prepared. This 100 μl sample volume included 20 μl APC-Mouse Anti-Human CD15 antibody (BD-BioSciences), 5 ul Brillant Violet 421-Mouse Anti-Human CD16-antibody (BD Biosciences), and 2 μl 0.1 mM Syto 16 Green Fluorescent Nucleic Acid Stain (ThermoFisher). DMEM (Lonza BioWhittaker 4.5 g/L glucose without Glutamine or Phenol Red) was added to samples to bring volume to 100 μl for each white blood cell sample. White blood cell samples with antibodies were mixed on a rotator for 30 minutes at room temperature, then rinsed in DMEM buffer, and spun down at lowest speed possible to remove unbound antibody. 1% PFA was added and incubated at room temperature for 20 minutes to fix cells. Labelled cells were rinsed with DMEM and spun out of solution at lowest speed possible to separate out the PFA. Labelled cells were resuspended in 50 μl DMEM buffer and spread evenly onto prepared coverslips, and then air-dried. Mowiol mounting solution (Calbiochem) was layered over cells on coverslips, and coverslip was mounted onto a microscope slide. These slides were placed in a dark place overnight at room temperature to allow the Mowiol to harden. Slides with prepared labelled cells were stored in the dark until imaged.
Imaging
Samples were imaged using a high throughput microlens array microscope4,6. Plano-convex refractive microlenses are fabricated by replica molding a photoresist master into Norland Optical Adhesive 61 (n = 1.56). Microlenses are arranged in a hexagonal grid, with focal length 300 μm and diameter 122 μm. Brilliant Violet, Syto 16 and APC channels were imaged sequentially by exciting with 405, 488 and 647 nm lasers, respectively. The total excitation power at the microlens array is roughly 65 mW for each laser. Long pass emission filters were employed together with a quad-band dichroic beam splitter to eliminate laser scatter. The excitation laser beam is expanded and projected into a weakly diverging 2 × 2 cm square on the flat side of the microlenses. Each microlens focuses the incident light into a spot at its focus. The sample is placed at the focal plane of the microlens array, resulting in fluorescence emission. This fluorescence is captured by each microlens, and directed back towards a large single lens reflex (SLR) lens (Nikon, focal length = 50 mm, f/1.4). The SLR lens images the back aperture of all microlenses onto a fast CMOS camera running at 200 frames per second (Point Grey Grasshopper 3 GS3-U3-23S6M-C). To build up a point scanning image for the portion of the sample under each microlens, the sample is raster scanned over a 130 × 118 μm under the microlens array, at a sampling frequency of 0.5 μm/pixel. The fluorescence emission at any given point in the image is given by the brightness of the pixels that make up the image of the microlens on the camera sensor.
Data Processing
After imaging, all subsequent data and image processing is performed in MATLAB. Transforming the raw point scanning data into 2D images first requires the position of each microlens in the array to be identified. A reference microlens array image is constructed by taking the average of the raw camera sensor image over 1000 frames. The periodicity of the hexagonal microlens array is obtained by computing the 2D Fourier transform of the reference image, and locating the peak positions in the spatial frequency domain. A digitally constructed template hexagonal grid with identical periodicity to the reference image is then cross-correlated with the reference image. The peak cross correlation value within one hexagonal cell indicates the necessary translation of the template to match the reference image. The location of the centre of each hexagonal cell in the template grid is indexed with a microlens identification number, so that pixels in the reference image can be linked directly to a microlens index. The sub-image recorded by each microlens is extracted by arranging pixel intensities in lines, with 260 pixels (130 μm) per line.
Image Processing
Sub-images with large background (large minimum intensity values) are discarded. The image recorded at each microlens position is thresholded using Otsu’s method to isolate WBC nuclei. The resulting binary image is further subjected to a variety of MATLAB morphological operations to clean object boundaries (MATLAB functions bwareaopen and bwmorph, operations used: ‘bridge’, ‘diag’, ‘spur’, ‘hbreak’, ‘clean’, ‘remove’, ‘thicken’, ‘holes’). The resulting binary image is shown in Fig. 1d, with each object (WBC nucleus) labelled by colour. Each isolated region of Fig. 1d is used as a mask for a WBC nucleus image. Eccentricity, perimeter, area and solidity of each WBC nucleus region are calculated using the MATLAB regionprops function. CD15 and CD16 expression are calculated by summing the fluorescence intensity in the appropriate spectral channel over the region of each WBC nucleus mask. CD expression data can vary due to intrinsic brightness variation of the microlens image on the image sensor. This can be due to inaccurate microlens position identification or microlens efficiency variation throughout the array. This effect is corrected at two points in the image-processing pipeline. First, the intensity of each microlens FOV is scaled so that all FOVs have identical mean values (only pixels within cells are considered when calculating the mean). This correction is performed prior to segmentation. The second correction occurs after cell image and CD expression extraction. Because cell image extraction proceeds in a row-wise fashion across the entire FOV, any systematic spatial bias of CD expression levels is apparent when plotting CD expression against cell number (the first cell extracted is cell number 1, the next cell is cell number 2 and so on). This spatial bias is due largely to the angle between the pixel rows on the camera and the rows of microlenses. This effect manifests itself as periodic variation in CD expression as the cells are extracted from microlens FOVs that snake from top left to bottom right of the cm-scale large FOV. To correct for this bias, we low pass filter the CD expression trace (ie. the plot of CD expression vs. cell number) such that intra-FOV CD expression variation (which is what we want to capture) is averaged out, leaving only the systematic inter-FOV variation. Then, the original CD expression trace is divided by the low-pass filtered trace, eliminating systematic intensity variations. When normalized to its highest value, we refer to the low pass filtered trace as the intensity correction factor. This factor is used in the gating process to establish the quality of the dictionary images. This process is performed for both CD15 and CD16 channels.
Gating
WBC images containing nuclei from two different WBCs are identified and eliminated by gating out cellular populations with large area and large eccentricity. For dictionary construction, we further narrow down the WBCs used. We discard all WBCs found in fields-of-view where the intensity correction factor is greater than 1.33. The dotplot in Fig. 3 shows only datapoints corresponding to cells with an intensity correction factor less than 1.33. This ensures that the WBCs in the dictionary have highly accurate CD expressions values (larger correction values come with higher uncertainty), and therefore that they are found in the correct gate. Remaining WBCs are subsequently gated into R1-R4 populations based on CD15/CD16 expression
Noise Simulation
For noisy classification and denoising examples, noise is added to the original cell nucleus images (ground truth) using the MATLAB “imnoise” function. The SNR of the original dataset is 90, calculated by taking the mean pixel values within a cell, divided by the standard deviation of the pixel values in background regions. The SNR is calculated in the same way for synthetic noisy images.
Quadratic Discriminant Analysis Classification
As a comparison to a traditional classification technique, we use Quadratic Discriminant Analysis25 to classify cell nuclei based on their area, perimeter, circularity, eccentricity and solidity. These 5 properties form a 5-dimensional feature vector for each cell based on segmentation from the background. Segmentation proceeds as in “Image Processing”.
Additional Information
How to cite this article: Orth, A. et al. Dictionary-enhanced imaging cytometry. Sci. Rep. 7, 43148; doi: 10.1038/srep43148 (2017).
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
Huang, K. & Murphy, R. F. From Quantitative Microscopy to Automated Image Understanding. J. Biomed. Opt. 9, 893–912 (2004).
Shariff, A., Kangas, J., Coelho, L. P., Quinn, S. & Murphy, R. F. Automated image analysis for high-content screening and analysis. J. Biomol. Screen. 15, 726–734 (2010).
Pepperkok, R. & Ellenberg, J. High-throughput fluorescence microscopy for systems biology. Nat. Rev. Mol. Cell Biol. 7, 690–696 (2006).
Orth, A. & Crozier, K. Microscopy with microlens arrays: high throughput, high resolution and light-field imaging. Opt Express 20, 13522–13531 (2012).
Orth, A. & Crozier, K. Gigapixel fluorescence microscopy with a water immersion microlens array. Opt. Express 21, 2361–2368 (2013).
Orth, A. & Crozier, K. B. High throughput multichannel fluorescence microscopy with microlens arrays. Opt. Express 22, 18101–18112 (2014).
Orth, A., Tomaszewski, M. J., Ghosh, R. N. & Schonbrun, E. Gigapixel multispectral microscopy. Optica 2, 654–662 (2015).
Isikman, S. O., Greenbaum, A., Luo, W., Coskun, A. F. & Ozcan, A. Giga-pixel lensfree holographic microscopy and tomography using color image sensors. PloS One 7, e45044 (2012).
Zheng, G., Ou, X. & Yang, C. 0.5 gigapixel microscopy using a flatbed scanner. Biomed. Opt. Express 5, 1–8 (2014).
Arpali, S. A., Arpali, C., Coskun, A. F., Chiang, H.-H. & Ozcan, A. High-throughput screening of large volumes of whole blood using structured illumination and fluorescent on-chip imaging. Lab. Chip 12, 4968–4971 (2012).
Bickle, M. The beautiful cell: high-content screening in drug discovery. Anal. Bioanal. Chem. 398, 219–226 (2010).
Zanella, F., Lorens, J. B. & Link, W. High content screening: seeing is believing. Trends Biotechnol. 28, 237–245 (2010).
Theera-Umpon, N. & Dhompongsa, S. Morphological granulometric features of nucleus in automatic bone marrow white blood cell classification. IEEE Trans. Inf. Technol. Biomed. Publ. IEEE Eng. Med. Biol. Soc. 11, 353–359 (2007).
Hiremath, P. S., Bannigidad, P. & Geeta, S. Automated identification and classification of white blood cells (leukocytes) in digital microscopic images. IJCA Spec . Issue ‘recent Trends Image Process. Pattern Recognition’ RTIPPR 59–63 (2010).
Rohde, G. K., Ribeiro, A. J. S., Dahl, K. N. & Murphy, R. F. Deformation-based nuclear morphometry: Capturing nuclear shape variation in HeLa cells. Cytometry A 73A, 341–350 (2008).
Kårsnäs, A., Larsen, R. & Dahl, A. Learning histopathological patterns. J. Pathol. Inform. 2, 12 (2011).
Yang, L. et al. Parallel content-based sub-image retrieval using hierarchical searching. Bioinformatics btt623, doi: 10.1093/bioinformatics/btt623 (2013).
Freeman, W. T., Jones, T. R. & Pasztor, E. C. Example-based super-resolution. Comput. Graph. Appl. IEEE 22, 56–65 (2002).
Elad, M. & Aharon, M. Image denoising via sparse and redundant representations over learned dictionaries. Image Process. IEEE Trans. On 15, 3736–3745 (2006).
Marwah, K., Wetzstein, G., Bando, Y. & Raskar, R. Compressive light field photography using overcomplete dictionaries and optimized projections. ACM Trans. Graph. TOG 32, 46 (2013).
Diego, F., Reichinnek, S., Both, M. & Hamprecht, F. A. Automated identification of neuronal activity from calcium imaging by sparse dictionary learning. In 2013 IEEE 10th International Symposium on Biomedical Imaging 1058–1061 (IEEE, 2013).
Hu, T. et al. Electron microscopy reconstruction of brain structure using sparse representations over learned dictionaries. IEEE Trans. Med. Imaging 32, 2179–2188 (2013).
Naeim, F., Rao, P. N. & Grody, W. W. Hematopathology: Morphology, Immunophenotype, Cytogenetics, and Molecular Approaches. (Academic Press, 2009).
Ortolani, C. Flow Cytometry of Hematological Malignancies. (John Wiley & Sons, 2011).
McLachlan, G. Discriminant Analysis and Statistical Pattern Recognition. (John Wiley & Sons, 2004).
Wong, K. L. et al. The three human monocyte subsets: implications for health and disease. Immunol. Res. 53, 41–57 (2012).
Orth, A. Classification of white blood cell nuclei http://gigapan.com/gigapans/194956 (2016).
Kolaczkowska, E. & Kubes, P. Neutrophil recruitment and function in health and inflammation. Nat. Rev. Immunol. 13, 159–175 (2013).
McClatchey, K. D. Clinical laboratory medicine. (Lippincott Williams & Wilkins, 2002).
Mortensen, K. I., Churchman, L. S., Spudich, J. A. & Flyvbjerg, H. Optimized localization analysis for single-molecule tracking and super-resolution microscopy. Nat. Methods 7, 377–381 (2010).
Boland, M. V. & Murphy, R. F. A neural network classifier capable of recognizing the patterns of all major subcellular structures in fluorescence microscope images of HeLa cells. Bioinformatics 17, 1213–1223 (2001).
Murphy, R. F. Putting proteins on the map. Nat. Biotechnol. 24, 1223–1224 (2006).
George, T. C. et al. Distinguishing modes of cell death using the ImageStream® multispectral imaging flow cytometer. Cytometry A 59, 237–245 (2004).
Orth, A. 260k white blood cell nuclei http://www.gigapan.com/gigapans/189594 (2016).
Orth, A. WBC smear http://www.gigapan.com/gigapans/189654 (2016).
Acknowledgements
The authors would like to acknowledge funding from Thermo Fisher Scientific and from the Rowland Junior Fellow program.
Author information
Authors and Affiliations
Contributions
A.O., E.S. and D.S. designed the experiments. D.S. prepared samples. A.O. performed imaging experiments. A.O. analysed data. A.O., E.S. and D.S. wrote the manuscript. E.S. supervised the research.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Orth, A., Schaak, D. & Schonbrun, E. Dictionary-enhanced imaging cytometry. Sci Rep 7, 43148 (2017). https://doi.org/10.1038/srep43148
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep43148
This article is cited by
-
A dual-mode mobile phone microscope using the onboard camera flash and ambient light