Abstract
Aluminum in its Al3+ form is a metal that inhibits plant growth, especially in acidic soils (pH < 5.5). Rapid and accurate quantitative detection of Al3+ in agricultural soils is critical for the timely implementation of remediation strategies. However, detecting metal ions requires time-consuming preparation of samples, using expensive instrumentation and non-portable spectroscopic techniques. As an alternative, electrochemical sensors offer a cost-effective and minimally invasive approach for in situ quantification of metal ions. Here, we developed and validated an electrochemical sensor based on bismuth-modified laser-induced graphene (LIG) electrodes for Al3+ quantitative detection in a range relevant to agriculture (1–300 ppm). Our results show a linear Al3+ detection range of 1.07–300 ppm with a variation coefficient of 5.3%, even in the presence of other metal ions (Pb2+, Cd2+, and Cu2+). The sensor offers a limit of detection (LOD) of 0.34 ppm and a limit of quantification (LOQ) of 1.07 ppm. We compared its accuracy for soil samples with pH < 4.8 to within 89–98% of spectroscopic methods (ICP-OES) and potentiometric titration. This technology's portability, easy to use, and cost-effectiveness make it a promising candidate for in situ quantification and remediation of Al3+ in agricultural soils and other complex matrices.
Similar content being viewed by others
Introduction
Aluminum is one of the most abundant metallic elements on Earth, and it is found in the form of Al2O3 in over 15% of the Earth’s crust1. Its Al3+ form, prevalent in dry soils, is phytotoxic because it inhibits nutrient uptake by plant roots and hinders their growth. Its capacity to displace nutrient ions in cation exchange sites and bind to the root elongation zone, and its bioavailability in acidic soils (pH < 5.5), make it one of the main limiting factors in crop productivity1,2.
The advent of sensing technologies for rapidly detecting this ion in phytotoxic concentrations (> 2 ppm) provides a starting point for remediation to salvage the productivity of crops, particularly in acidic agricultural lands3. Furthermore, these technologies open the door to implementing new strategies to improve crop selection and optimize breeding4. However, the detection of trace metals has primarily been performed using spectroscopic methods, including inductively coupled plasma via mass or optical emission spectrometry (ICP-MS/OES), that require expensive instruments, materials, and qualified operators5. Therefore, these methods are not suitable for routine analysis of multiple samples6, which severely limits their application for widespread use in agriculture.
Colorimetric/fluorescence7,8,9 and electrochemical5,10,11 systems are considered cost-effective alternatives for identifying and quantifying metal ions in various matrices. Selective colorimetric and fluorescent probes enable fast visual identification of analytes. Still, in-the-field quantification remains a challenge. Recent studies demonstrate the use of carbon-based nanostructured electrodes for the electrochemical detection of metal ions with high reproducibility, sensitivity, and selectivity12,13,14,15. Among the carbon nanostructures used to fabricate these sensors, Laser-Induced Graphene (LIG) has most recently garnered attention for its simple manufacture, low cost, biocompatibility16, and potential for increased surface area, trough surface treatments that can enhance sensitivity and intensify the signals of the analyte of interest17. LIG electrodes have been shown to work for gas sensors18, biosensors19,20, among others16,21,22,23, across a wide range of applications in healthcare, environmental monitoring, and quality control in manufacturing.
Recent studies have reported the feasibility of LIG-based electrochemical sensors for detecting metal ions such as Cd2+ and Pb2+24,25. However, this technology requires understanding the nature and behavior of the graphene-based substrate material for each application26, since detecting metal ions with LIG electrodes depends on the material’s functionalization and the electrochemical technique used. Bismuth-based electrodes are ideal for heavy metal ion sensing due to their ability to electrodeposit elements on their surface through the formation of intermetallic compounds27. Additionally, bismuth (Bi) exhibits very low toxicity and possesses suitable electrochemical properties, including low background currents and the ability to separate intermetallic compounds27,28,29,30. Electrochemical techniques, such as square wave voltammetry represent highly sensitive detection methods for metal ions. This is due to their involvement of a preconcentration step and the continuous adsorption and desorption of the metal ions31,32. Prior studies using bismuth-functionalized electrodes and square wave voltammetry (SWV) have shown promising results in metal ion detection. Among these, Yi et al33. and Jeong et al25. successfully quantified Cd2+ in real water samples. Additionally, investigations carried out by our research group showcased the feasibility of this method in detecting trace amounts of Al3+ in an experimental solution34.
Detecting metals in foods or food sources requires sensitivities in parts per billion (ppb) concentrations when accumulation of trace amounts pose an immediate risk to human health35. This is the case of Cadmium (Cd), Mercury (Hg), Lead (Pb), and other heavy metals36,37,38. Human exposure to aluminum, on the other hand, is unavoidable in today’s world. Although chronic buildup of biologically reactive aluminum can lead to serious health problems, it is rarely acutely toxic39. However, Al3+ can be phytotoxic for plants when its concentration exceeds 2–3 ppm in soil40,41, including tolerant crops like rice and maize, where concentrations around 40–80 ppm of this ion have been associated with decreased biomass production in these species42,43,44.
While various electrochemical-based sensors for specific Al3+ detection have been developed, they primarily operate within a range designed to determine trace amounts of this metal ion, mainly within the low ppb range34,45,46,47. Unfortunately, the critical phytotoxic threshold to effectively monitor the Al3 + content in agricultural soils starts at 0.3 ppm and extends beyond > 200 ppm48,49. None of the existing technologies cover this range. Here, we report for the first time, the development, characterization, and validation of a cost-effective, discardable electrochemical sensor based on LIG for accurately detecting and quantifying Al3+ in soils within the relevant concentration range for phytotoxicity in plants (ppm). The remainder of this document describes the materials and methods used in the fabrication of our disposable LIG-based electrochemical Al3+ sensors, the electrochemical methods used to characterize Al3+ concentrations using this sensor, the morphological and chemical characterization of the functionalized sensing electrode, and its Al3+ sensitivity and selectivity in the presence of other metal ions (Pb2+, Cd2+, and Cu2+), and the validation of the sensor using reference soil samples. We close by listing the key contributions and potential applications of this technology.
Materials and methods
Reagents
The standard stock solution of Al (III) 1000 mg L−1 was purchased from MOL LABS. The other reagents, including Pb (II), Cd (II) and Cu (II) (1000 mg L−1) standards, were purchased from SIGMA (ref: 41,318; 36,379). A stock Bi (III) solution 0.2 mol L−1 was prepared by adding Bi(NO3)3·5H20 into acetate solution (sodium acetate + acetic acid 0.1 mol L−1) at pH 3.70. Working solutions were prepared in a concentration range from 1 to 300 ppm by diluting the stocks in acetate solution at 0.1 mol L−1 (pH 3.70) containing the Bi (III) solution at 0.1 mol L−1. The Ferri solution used for electrochemical characterization consisted of a solution of potassium hexacyanoferrate (III) [K3Fe (CN)6] 2 mmol L−1 (Alfa Aesar, ref: 33,357) with H2SO4 0.18 mol L−1. All solutions were prepared with ultrapure water obtained from Thermo Fisher Scientific Barnstead SMART2PURE water system, with conductivity 18.2 Ω. For LIG fabrication, we used Polyester Diagnostic Tape (PT) (3 M™, ref: 9964) as a substrate, 50 mm thickness Polyimide (PI) film (Shijiazhuang Dadao Packaging Materials Co., Ltd), PELCO® Conductive Silver Paint (Ted Pella Inc, ref: 16,062) for all electrode contact points, and Silver/Chloride-silver (Ag/AgCl) ink (DuPont™, ref: 5874) for the pseudo-reference electrode.
Fabrication, cleaning, and in situ preparation of LIG-based electrochemical sensors.
LIG-based planar electrochemical cells with three electrodes (working, reference and counter) were fabricated from PI (see Figure S1), using an FSL Muse 3D (Full spectrum laser) equipped with a 45 W CO2 laser (λ = 10.6 μm). The working electrode was set to a diameter of 4 mm. Lasing was performed at 9 W of power, at a laser head speed of 19.5 cm/s, using raster mode, and a constant laser lens focal distance to the polyimide sheets of 4.65 mm. These parameters were chosen, taking into account our earlier laser optimization studies50, to achieve the highest quality LIG suitable for sensing applications of this nature. The use of Ag/AgCl for the pseudo-reference electrode (RE) material is known to provide a consistent and reproducible potential51,52 Thus, we coated the pseudo-reference electrode (RE) with Ag–AgCl ink, and used an Ag ink to improve the mechanical stability and conductivity for all electrode contacts, as depicted in Fig. 1d. To improve the chemical potential stability of the pseudo-RE, we incubated it overnight with 100 ml of KCl solution at 3 mol L−1. This is the standard background solution for preserving the commercial Ag/AgCl electrode53. Excess KCl was washed off the RE with Type I water before being cleaned with successive Cyclic Voltammetry (CV) scans using a 2 mmol L−1 [K3Fe (CN)6] + H2SO4 0.18 mol L−1 solution over a potential range of − 0.25–0.6 V and a rate of 0.10 V s−1. Several CV scans are often conducted to eliminate any adsorbed species from the electrode surface54. This procedure was repeated until a smooth voltammogram form was obtained (up to six scans, see Figure S1). Five additional cycles were performed to confirm the sensor’s electrochemical repeatability (Fig. 1c). Then 40 μl of the working solution, containing both Bi (III) and the sample, was deposited and preconcentrated onto the WE surface for anodic stripping analysis. This resulted in in-situ electrodeposition of Bi (III), which reduces the complexity and time for modifying the WE, compared to a priori functionalization34,55. In the case of incremental measurements we conducted an electrochemical desorption step right after the stripping step and before adding the subsequent working solution over the surface of the same WE. This by applying an oxidizing potential of + 1.6 V for 60 s to remove the excess of Bi-Al3+ using the same working solution.
Electrochemical detection of Al3+
Electrochemical experiments were conducted via Square Wave Anodic Stripping Voltammetry (SWASV), with a pre-concentration for measuring trace metals56. The procedure consists of preconcentrating the WE with the Bi3+ and Al3+ mixture for 60 s at a potential of − 1.40 V, followed by successive stripping potential cycles between − 2.00 to − 0.50 V, at 2 mV step potential, using an SW amplitude of 20 mV and a frequency of 25 Hz. These parameters were selected based on our previous research findings34, and also considering relevant studies, such as the work by Jeong et al25. and Anastasiadou et al56. Each stripping current (Ip) (Figure S2) was recorded to build the calibration curve for Al3+ quantification over eleven different aluminum concentrations (1, 5, 10, 20, 40, 70, 100, 125, 200, 225, and 300 ppm). A different set of electrodes was used per concentration. On a single sensor cell, another calibration curve was constructed for incremental depositions over the same range intervals (Figure S3). For interference analysis, we added Pb2+, Cd2+, and Cu2+ ions to each sample at the same Al3+ concentrations. Then 40 μl of each sample was drop-casted on the WE surface before performing electrochemical characterization. We confirmed the stability over time (longevity) of the electrochemical sensor’s response to Al3+, by characterizing samples with 1, 100, and 200 ppm Al3+ concentrations using three different electrodes, after 1, 15 and 30 days of fabrication. (Figure S4). All electrochemical tests were performed using a reference potentiostat–galvanostat (Metrohm Autolab model PGSTAT302N, with the software NOVA 2.1).
Morphological, chemical and structural characterization
To study the changes in the morphology of the bare and modified WEs, we used a Tescan Clara Field Emission Scanning Electron Microscope (FE-SEM) equipped with energy-dispersive electron X-ray (EDX) analysis system for chemical identification, and Thermo Fisher DXR SmartRaman spectrometer, with a 532 nm laser, 6 mW power in a range between 1000 and 3000 cm−1. Porosity was estimated via digital image analysis using the imageJ image processing software57 from three different images of the WE, obtained with a low-energy backscattered electron (LE-BSE) detector at 40 Kx magnifications, and an acceleration voltage of 10 kV.
Al3+ extraction procedure from soil samples
The analytical services laboratory from the CIAT-Bioversity Alliance supplied soil samples. Three samples were collected from the Cauca, Carimagua, and Santander regions in Colombia. The last two are considered main cocoa-producing regions, which are known to have dry and acidic soils, and are used as an internal control for determining exchangeable Al3+ in soils through the volumetric standard method, potentiometric titration, and 1 mol L −1 KCl extraction58. The soil sample from Cauca was collected near an industrial zone, from a local sugarcane mill plantation. The pH was measured at 3.70, 4.10 and 4.50, via potentiometry, for Cauca, Carimagua, and Santander respectively. A reference soil sample from WEPAL (Wageningen Evaluating Programmes for Analytical Laboratories) ISE-2020-3-3.1, with a higher pH (5.40), was also measured. We followed the extraction protocols reported by Wang et al. Zhao et al. and Krasnodębska-Oskęga & Kowalska with slight modifications59,60,61. We added 40 ml of acetic acid at 0.43 mol L−1 at pH 2.62–1 g of the soil sample in a 50 ml propylene tube. The mixture was mechanically shaken for 60 min and then allowed to settle for another two minutes. The mixture was filtered using a plastic funnel with filter paper attached to a new 50 ml tube. The resulting filtrate was adjusted with NaOH 5 mol L−1 to a pH of 3.70 and used as a direct substrate for subsequent analyses. For further validation, Al3+ content in the samples was also determined by Inductively Coupled Plasma with Optical Emission Spectroscopy (ICP-OES) Series iCAP™ 7000 and a Flame Atomic Absorption Thermo Scientific S4.
Al3+ diagram species
To study the behavior of Al3+ metal ions in aqueous acetate solution within the pH range considered. We simulated the species distribution diagrams (Figure S5a) using the free software MEDUSA (Windows interface) and HYDRA (database manager) developed by Puigdomenech. The resulting simulations agreed with speciation diagrams described in the literature for similar systems62,63,64,65,66. These curves were then used for pH correction in the determination of Al3+ in soil extracts with the sensor developed in this work. To create this species diagram, we used a total acetate ion concentration of 0.100 mol L−1 and Al3+ ion concentration of 10 ppm. Other species diagrams have also been made for other Al3+ concentrations, but the percentage of free Al3+ is always similar.
Based on the species diagram, we constructed (Figure S5b), which illustrates the overestimation of Al3+ at pH values above 3.70 and the underestimation at lower pH values. To obtain these estimates, we assumed that the measurement at pH 3.70 has 100% accuracy. To obtain the values at other pH values, we divided the measurement obtained at pH 3.70 by the percentage of underestimation or overestimation. Figure S5a show that detecting Al3+ at pH above 4.80 will be difficult due to other masking aluminum species. Therefore, pH values up to 4.80 are considered optimal for quantifying Al3+ using the technology reported here.
Results and discussion
Morphological and electrochemical characterization of bare LIG electrodes
Structural characterization of the LIG material in our electrodes was performed using Raman spectroscopy. Figure 1a shows representative Raman spectra of our LIG, in which bands D (\(\sim\)1350 cm−1), G (\(\sim\)1580 cm−1) and 2D (\(\sim\)2700 cm−1) indicate the presence of multilayered graphene scales (I2D/IG ≈ 0.77), with a proportionally-low concentration of disorder and a small average inter-defect distance (ID/IG ≈ 0.67)67,68. The estimated in-plane size of the graphene scale crystallites (La) is 28.6 nm, obtained from \({L}_{a}[nm]=(2.4\times {10}^{-10}){\lambda }^{4}({I}_{G}/{I}_{D})\)69, where λ [nm] is the radiation wavelength that induces Raman scattering. Figure 1b shows an SEM image of the morphology of one WE, including laminar graphene sheets, pores, and fibers at the edges of the sheets.
Electrochemical characterization of each LIG electrode was performed by a series of five CV scans, with 2 mmol L −1 K3Fe (CN)6 + H2SO4 0.1 mol L −1 and a potential window of − 0.25–0.6 V. An acidic medium was chosen to improve the electron transfer between the LIG surface and the analyte of interest, as reported by Saveant’s group70,71. A representative CV from one WE are shown in Fig. 1c. This shows that the redox behavior of K3Fe(CN)6 over the LIG electrode surface was a chemically and electrochemically reversible process, with a peak-to-peak separation (∆Ep) of 75 mV and an anodic to cathodic peak current ratio (Ipa/Ipc) close to 115,54,72. This validates our LIG-WE, providing a suitable potential window and current range to perform further electrochemical analysis.
Working electrode surface functionalization for Al3+ detection
Metal ions detection by SWASV with in situ bismuth deposition is a method that depends on Bi (III) concentration and the pH of the solution30,73,74,75. These parameters are optimized to obtain the highest stripping peak current in the SWASV for the analyte under study25,76. To achieve the highest sensitivity, we determined the solution's optimal Bi concentration and pH for Al3+ detection. For the Bi (III) analysis, we used SWASV to measure the peak current for Al3+ while increasing the concentration of Bi from 10 to 1600 ppm, as shown in Fig. 2a. Measurements were made independently for a low (0.5 ppm) and a high (200 ppm) concentration of Al3+. The highest peak current in both cases was 1000 ppm of Bi, consistent with previous studies on other metal ions, such as Cd2+ and Pb2+. This confirmed that the best stripping response is obtained at a Bi concentration five to 10 times higher than that of the analyte in solution25,73,77. After 1000 ppm Bi, the peak current starts to decrease, which indicates the formation of a Bi film and anchor site saturation for this species on the WE. This limits the mass transfer for Al3+ diffusion in the electrochemical system25,73, and affects the reproducibility in deposition kinetics dynamics of the analyte over the WE surface, which explains the increased error bars at the saturation point around 1200 ppm Bi. Consequently, we set the maximum Bi concentration at 1000 ppm.
We also measured the peak current of two concentrations (low and high) of Al3+, while varying the pH of the acetate solution from 3.0 to 5.3 (Fig. 2b). The highest peak current for Al3+ concentrations was obtained at a pH of 3.7. Below this value, we see a drop in peak current associated with the hydrogen evolution reaction (HER) that occurs on the WE surface, which limits the deposition of the target ion78,79,80. Above a pH of 3.7, the decrease in peak current can be explained by hydrolysis reactions of Al3+15 and the formation of metal hydroxides as evidenced in the speciation diagram for this ion, where the formation of Al(OH)2+ species starts to increase at pH 449,81. Therefore, we set the sensing solution pH at 3.7.
Incremental and one-time quantification of Al3+ using our LIG-based sensor
We performed quantification analysis of Al3+ samples deposited during in situ Bi preparation with SWASV as described previously. The results are shown in Fig. 3a, where the peak current for Al3+ in solution was 1200 µA at around 0.10 V above a concentration of 100 ppm. Using the data from this curve, we constructed a linear calibration curve (with an R2 fit of 0.99) as shown in Fig. 3b. Each point in the figure corresponds to the average of at least three independent measurements, and the error bars were calculated using the standard deviation. It is important to note that a different LIG-based sensor was used for each case to ensure accuracy and reproducibility of the results.
The peak form shown in Fig. 3a is a typical response to electrochemical adsorption processes on the electrode surface82. As described previously34, the relationship between the peak current and the number of species adsorbed on the surface per unit volume (Γ*) can be expressed by equation, \({I}_{p}=({n}^{2}{F}^{2}/4RT)vA{\Gamma }^{*},\) where Ip is the peak current, n is the number of electrons transferred, F is the Faraday constant, R is the gas constant in J mol–1 K –1, T is the temperature, v is the scan rate, A is the area of the electrode. Thus, higher peak currents correspond to a higher number of species absorbed on the surface. These results accurately reflect the relationship between peak current and the concentration of Al3+ deposited on the surface of the WE.
To investigate the capability of a single LIG-based sensor for quantifying different concentrations of Al3+ we performed stepwise deposits of aluminum on the WE, from 1 to 200 ppm (intervals listed previously). Figure 3a and c show that SWV stripping response increases as a function of Al3+ concentration, with the potential shifting to more positive values as the concentration increases. The change in the electrode response is due to the co-precipitation of bismuth and aluminum atoms. The concentration ratio of bismuth to aluminum ions changes the electron dynamics across the interface, primarily due to an increased film thickness. The bismuth film modifies the WE, and contributes to a well-defined, undistorted, and highly reproducible stripping response, with high-resolution neighboring peaks, high hydrogen evolution, a wide linear dynamic range, and a good signal-to-background characteristic, as explained by Wang83. The current peak shifts to more oxidative potentials for increasing film thicknesses are explained by the Hubbard model, i.e. more time is required to reduce the film of electroactive species84. This explains the changes observed between the response recorded for the baseline (only bismuth) and each of the increasing concentrations of Al3+ in the working solution, for both cases, one-time (Fig. 3a) and incremental measurements (Fig. 3c), with the latter exhibiting a more pronounced shift due to the cumulative deposition of both bismuth and Al3+ over the same WE surface.
The calibration curve for incremental measurements is shown in Fig. 3d. In contrast to the results obtained with separate LIG-based sensors per concentration, here, the linear trend is maintained up to 100 ppm of Al3+ (Figure S3); after which, the signal strength decreases until a plateau is reached by 200 ppm. We believe this is because the number of available electronically active sites on the WE decrease during incremental deposition of Bi. As suggested by Baldrianova73, increasing the deposition time and/or Bi concentration under potentials that are less than − 0.95 V leads to a non-uniform thickness of the deposited analyte and dendritic growth. This non-uniform growth can cause high local current densities, which in turn reduce the current efficiency of Bi deposition and deposition rates73 and thus result in non-linear responses. This is observed in our SEM micrographs in Fig. 4. While our calibration curves confirm the reproducibility of our system, we note that variability in the bismuth deposition kinetics may impact the reproducibility of electrode measurements85. This variability could potentially account for any slight discrepancies in the electrode’s response observed during incremental measurements. According to Dossi et al85, the use carbonate solution in the desorption step described in Sect. 2.2. could potentially remove more efficiently the accumulated Bi over the WE surface, thus decrease the layer thickness.
Morphological and chemical characterization of the modified LIG electrode
We used field emission scanning electron microscopy (FE-SEM) micrographs to evaluate the effects of the electrochemical modification on the morphology of the LIG surfaces. The analysis was performed on LIG-based electrodes used for incremental and single Al3+ measurements at 1, 100, and 200 ppm concentrations. In both cases, the adsorption of Bi occurred mainly at the edges of the graphene sheets, as shown in Fig. 4. This was expected, considering the number of edge defects and the presence of functional chemical groups with unpaired electrons that are highly active catalytic sites86,87. At 1 ppm, we observe that bismuth is deposited on the edges of LIG scales for both incremental and single-concentration measurements. However, for the incremental case, we find that the bismuth-Al3+ forms a lattice-like surface network with pores that are inversely proportional in size to the Al3+ concentration. To confirm this effect, we estimated the change in porosity from a set of FE-SEM images (Figure S6) where the porosity of the LIG surface decreased from 19.3% at 1 ppm, 13.3% at 100 ppm, and 12.1% at 200 ppm. The saturation of electronically active sites on the LIG edges (Fig. 4c) occurs past 200 ppm, hence our decision to set this upper limit.
FE-SEM micrographs for LIG surfaces with single Al3+ deposition at concentrations above 100 ppm led to dendritic growth (Fig. 4e and f). The formation of these structures is mainly due to non-uniform metal deposition on the LIG scale edges, which depends on the Al3+/Bi3+ exchange reaction rates, the electrolyte’s transport rate, the self-diffusion barrier for the Al3+/Bi clusters, and the anisotropy of these analytes. Once the edges are saturated, growth continues at the existing metalized sites instead of on the graphene-scale planes. This has already been documented for Li and Bi interacting with other metals88,89,90,91. The branched dendritic structures lead to a larger electrochemically-active surface area that favors an increase in electronic conductivity, which explains the linear electrochemical response beyond 100 ppm, as shown in Fig. 3b 90. Interestingly, the dendritic structures appear to float above the surfaces of the graphene scales, after nucleating at their edges (Figure S7). Dispersion interactions and interactions with the out-of-plane pi-orbitals in graphene could favor their parallel orientation, with respect to the graphene surface.
The compositional analysis after functionalization was performed using a (FE-SEM), the Tescan model Clara equipped with an energy-dispersive electron X-ray (EDX) analysis system. Figure 5 shows the following images: (a) obtained at 5 kx magnification in backscattered mode to identify elements other than the electrode, (b) focused at 50 kx magnification in areas where Bi-dendritic structure growth was observed. Image (c) presents a homogeneous surface distribution of the elements carbon (C), oxygen (O), gold (Au) and bismuth (Bi) through chemical mapping analysis (EDX). EDX analysis (Fig. 5d) revealed chemical composition spectrum indicating the presence of peaks corresponding to C, O, Au and Bi. C and O are primarily in the form of graphene oxide, Au was sputtered in a thin layer (1 nm) to obtain improve image resolution, Bi is related to the electrode in-situ functionalization. Due to the low concentrations (˂ 1000 ppm) of aluminum (Al), it was not detectable using the EDX technique, which has a typical resolution limit at 0.1%. These results confirm that the functionalized solution was adsorbed on the electrode surface.
Al3+ detection with our LIG-based sensor, in the presence of Cd2+, Pb2+, and Cu2+
To evaluate the ability of our system to detect and quantify Al3+ in the presence of other metal ions that are commonly found in agricultural soils, we performed negative control tests with binary and tertiary mixtures of Al3+, Cd2+, Pb2+, and Cu2+. Soils contaminated with Cd2+ and Pb2+ exhibit a sharp decrease in agricultural quality and their translocation from soil to plant tissues poses a significant threat to human health75,92. Despite being an essential nutrient for plants, it's important to note that copper can also be phytotoxic at high concentrations. Excessive copper levels (> 20 ppm93) can disrupt cellular processes, inhibit root growth, and lead to leaf chlorosis and necrosis. Copper toxicity usually occurs in acidic soils or due to excessive copper-based fungicide applications. But our intention is not to measure copper with the same electrode but to validate that it does not interfere with the oxidation potential for Bismuth in our electrochemical sensor94. Here, we applied SWASV on four different ion mixtures for Al3+, Cd2+, and Pb2+ (at 1, 100, and 200 ppm concentrations) diluted in the buffer-bismuth solution. Cu2+ mixtures were done at 1 and 100 ppm concentrations.
Figure 6a shows the SWASV of Al3+ in the presence of Pb2+. The stripping peak for both ions occur at different potentials of − 0.70 V and 0.10 V for Pb2+ and Al3+, respectively. With increasing concentration, the stripping response increases for both ions. But the signal is higher for Al3+. In binary mixtures with Cd2+, only the Al3+-bismuth peak is observed (Fig. 6b), because Cd2+ requires a longer deposition time or a more negative potential to induce a stripping response at higher concentrations (Figure S8). When Cd2+ and Pb2+ were evaluated (Fig. 6c), the stripping peak for both ions was detected at − 1.00 V and − 0.70 V, respectively, consistent with the reports of simultaneous detection of these ions25,95. However, the Cd2+ signal was not detected at 200 ppm. This can be related to competition between the different analytes for the active sites on the LIG-based surface at high concentrations95. Figure 6d shows the case of a tertiary mixture of Al/Cd/Pb with increasing currents at different potentials, even at 1 ppm. Here, the current peak for Al3+ is proportional to an increase in its concentration in solution, consistent with the results shown in Fig. 3. Detailed observations of the responses are available in Figure S9. All three metal ions are selectively distinguished, albeit with a higher selectivity for Al3+ when the applied potential is about 0.10 V. This is consistent with other studies showing the capability of bismuth-based sensors in conjunction with an SWV method for detecting multiple ions in the same sample simultaneously25,30,75,96. Our results show that our LIG-based sensor has the potential to detect Cd2+ and Pb2+ heavy metal ions, which pose a significant risk to human health and can be translocated by plants from the soil to the fruits that humans subsequently consume. Nevertheless, re-optimization of the electrochemical parameters such as pH, bismuth concentration, deposition times, and others is needed97,98, e.g. for the detection of cadmium in cocoa plants, where the Cd concentration in the beans can range from 0.02 to 12 ppm. In comparison, the Pb concentration can be as high as 1.28 ppm, indicating the need for highly sensitive detection methods such as the electrochemical sensor developed here98,99.
Copper has been reported to be a common interferent in bismuth-based electrochemical systems94,100,101, as it affects the deposition of bismuth and consequently the stripping response of the target analyte94. However, no significant differences were observed in the stripping peak for Al3+ compared to the peak of this ion in the mixture containing Cu2+ at 1 ppm as shown in Figure S10 (inset). Cu is found naturally in soils, ranging from 2 to 100 ppm and averaging about 30 ppm102,103. At the highest Cu2+ concentration in soil (100 ppm), a peaked shoulder appeared on the positive side of the Al3+ stripping current, indicating the detection of Cu2+ near a potential of 0.05 V (Figure S10a). This peak does not affect the stripping signal of Al3+ (Figure S10b), thanks to the excess of bismuth in the system, compared to Cu2+ ions and the specific electrochemical conditions standardized for Al3+ detection. Thus, neither copper nor other ions analyzed here introduce interference in our system.
Al3+ detection in solid extract samples using our LIG-based sensor
We evaluated the performance of our system under natural conditions by quantifying the concentration of Al3+ via the standard addition method in four reference soils: Cauca, Carimagua, and Santander regions, and ISE-2020-3-3.1 from WEPAL. Five solutions for each sample were characterized using our LIG-based sensors, all diluted samples (1:5) with endogenous Al3+, but at different standard concentrations (0, 10, 20, 40, and 70 ppm). We measured Al3+ content per sample by potentiometric titration, ICP-OES, and Flame Atomic Absortion (Table 1). Figure S11 shows the stripping voltammograms we obtained for the different Al3+ concentrations in each sample and their corresponding calibration curve (inset), which show an increase in the stripping current peak with increasing Al3+ concentration in the soil extract. We determined the Al3+ content in each soil sample by extrapolating to the standard addition curve (see Figure S12). Based on the Al speciation curve as a function of pH, we introduced a correction factor (Figure S5b) to account for the difference in pH between the soil and our measurement (at pH 3.70). As tabulated, the results agree well with potentiometric titration, ICP-OES, and flame atomic absorption (Table 1). This confirms that our LIG-based sensor can accurately measure Al3+ concentration in soil samples with a pH < 4.8, where this ion is predominant, as shown in Figure S5a.
The WEPAL sample gave an indeterminate value, consistent with our correction function at pH > 4.8 (Figure S5a). To corroborate this limitation, we examined two additional soil samples with intermediate and lower concentrations of Al3+, S-048-44 and S-139-1, at pH 5.07 and 5.32, respectively. Our corrected sensor values overestimate Al3+ for these cases (Table 1). There are other methods for determining the Al3+ concentration under these pH conditions, but they have a relatively high uncertainty due to the formation of metal complexes that bind the aluminum. This is why agricultural soils are often made alkaline; to promote metal complexes that the plant cannot absorb. Interestingly, although the activity of most Al species decreases between a pH of 4.8–5.5, phytotoxicity is still observed for some crops. Some authors suggest this is due to an increase in the Al3+ content in the root plasma membrane related to a dissociation of H+ from potentially negative ligands present in this structure during this pH range104. Even so, most Al3+ availability occurs when pH is below 548,104,105, where our system and extraction protocol gives accurate results. Further optimization of the extraction procedure is needed to determine the exchangeable Al3+ content in soil samples within the pH range between 5 and 5.5.
Conclusions
We demonstrate an Al3+ LIG-based electrochemical sensor with a linear detection range of 1.07–300 ppm for one-time measurements (single use) and 1.76–100 ppm for incremental measurements with the same electrode. This detection range is ideal for characterizing Al3+ concentrations in agricultural soils and determining potentially phytotoxic conditions. We show that in situ Bi modification of the WE offer an improved advantage in the fabrication protocol compared to state-of-the-art results. Another key result is that the same LIG-based Bi-functionalized sensing platform can selectively identify and measure the concentration of other metals of agronomic relevance, Cd, and Pb. Specifically, heavy metals like Cd and Pb are toxic to humans at relatively low concentrations (near the obtained LOD for our sensor). We also demonstrate that Cu, an essential element for plant growth, naturally found in soils, in some form or other, does not interfere with our sensor. Thus, the same Al sensing platform can determine toxic-to-human levels of Cd and Pb and phytotoxic levels of Al3+. Increasing the sensitivity for Cd and Pb would only require an adjustment in the Bi concentration and pH during the fabrication of the sensor. The low cost, ease of use, and straightforward scalability of our sensor are all factors that underscore its potential to improve agricultural practices, including performing and tracking soil amendments (e.g., liming) or monitoring phytoremediation strategies, such as using aluminum hyper-accumulating plants by determining the Al3+ content in its tissues.
Data availability
The Supporting Information is available free of charge on the Journal’s website. Supplementary information Al3+.pdf. The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Amist, N., Singh, N. B., Yadav, K., Singh, S. C. & Pandey, J. K. Comparative studies of Al 3+ ions and Al 2 O 3 nanoparticles on growth and metabolism of cabbage seedlings. J. Biotechnol. 254, 1–8. https://doi.org/10.1016/j.jbiotec.2017.06.002 (2017).
Rahman, M. et al. Importance of mineral nutrition for mitigating aluminum toxicity in plants on acidic soils: Current status and opportunities. Int. J. Mol. Sci. 19, 3073. https://doi.org/10.3390/ijms19103073 (2018).
Pan, F. et al. Quantitative assessment on soil concentration of heavy metal–contaminated soil with various sample pretreatment techniques and detection methods. Environ. Monit. Assess https://doi.org/10.1007/s10661-020-08775-4 (2020).
Jaramillo-Botero, A. et al. The ÓMICAS alliance, an international research program on multi-omics for crop breeding optimization. Front. Plant. Sci. 13, 1–20. https://doi.org/10.3389/fpls.2022.992663 (2022).
Bansod, B. K., Kumar, T., Thakur, R., Rana, S. & Singh, I. A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms. Biosens. Bioelectron. 94, 443–455. https://doi.org/10.1016/j.bios.2017.03.031 (2017).
Liu, H. et al. A strategy for As(III) determination based on ultrafine gold nanoparticles decorated on magnetic graphene oxide. Environ. Res. 231, 116177. https://doi.org/10.1016/j.envres.2023.116177 (2023).
Yin, P. et al. A new AIEE-active carbazole based colorimetric/fluorimetric chemosensor for ultra-rapid and nano-level determination of Hg2+ and Al3+ in food/environmental samples and living cells. Sens. Actuators B Chem. 331, 129418. https://doi.org/10.1016/j.snb.2020.129418 (2021).
Liu, T., Wan, X. & Yao, Y. Dual sensitive and selective sensor for Pb2+ and Al3+ with distinctive fluorescence response. Sens. Actuators B Chem. 254, 1094–1100. https://doi.org/10.1016/j.snb.2017.07.114 (2018).
Alici, O. & Erdemir, S. A cyanobiphenyl containing fluorescence turn on sensor for Al3+ ion in CH3CN–water. Sens. Actuators B Chem. 208, 159–163. https://doi.org/10.1016/j.snb.2014.11.033 (2015).
Wang, W. et al. Dual-recognition aptazyme-driven DNA nanomachine for two-in-one electrochemical detection of pesticides and heavy metal ions. Sens. Actuators B Chem. 321, 128598. https://doi.org/10.1016/j.snb.2020.128598 (2020).
Zhao, G., Wang, X., Liu, G. & Thuy, N. T. A disposable and flexible electrochemical sensor for the sensitive detection of heavy metals based on a one-step laser-induced surface modification: A new strategy for the batch fabrication of sensors. Sens. Actuators B Chem. 1(350), 130834. https://doi.org/10.1016/j.snb.2021.130834 (2022).
Behrent, A., Griesche, C., Sippel, P. & Baeumner, A. J. Process-property correlations in laser-induced graphene electrodes for electrochemical sensing. Microchim. Acta https://doi.org/10.1007/s00604-021-04792-3 (2021).
Pandey, S. K. et al. Nanocarbon-based electrochemical detection of heavy metals. Electroanalysis 28, 2472–2488. https://doi.org/10.1002/elan.201600173 (2016).
Rani, N. et al. Recent advancement in nanomaterials for the detection and removal of uranium: A review. Environ. Res. 234, 116536. https://doi.org/10.1016/j.envres.2023.116536 (2023).
Patel, M. et al. Ternary nanocomposite-based smart sensor: Reduced graphene oxide/polydopamine/alanine nanocomposite for simultaneous electrochemical detection of Cd2+, Pb2+, Fe2+, and Cu2+ ions. Environ. Res. 221, 115317. https://doi.org/10.1016/j.envres.2023.115317 (2023).
Kaidarova, A. & Kosel, J. Physical sensors based on laser-induced graphene: A review. IEEE Sens. J. 21, 12426–12443. https://doi.org/10.1109/JSEN.2020.3034845 (2021).
Liaquat, H., Imran, M., Latif, S., Hussain, N. & Bilal, M. Multifunctional nanomaterials and nanocomposites for sensing and monitoring of environmentally hazardous heavy metal contaminants. Environ. Res. 214, 113795. https://doi.org/10.1016/j.envres.2022.113795 (2022).
Stanford, M. G., Yang, K., Chyan, Y., Kittrell, C. & Tour, J. M. Laser-induced graphene for flexible and embeddable gas sensors. ACS Nano 13, 3474–3482. https://doi.org/10.1021/acsnano.8b09622 (2019).
Beduk, T. et al. Rapid point-of-care COVID-19 diagnosis with a gold-Nanoarchitecture-assisted laser-scribed graphene biosensor. Anal. Chem. 93, 8585–8594. https://doi.org/10.1021/acs.analchem.1c01444 (2021).
Wanjari, V. P., Reddy, A. S., Duttagupta, S. P. & Singh, S. P. Laser-induced graphene-based electrochemical biosensors for environmental applications: a perspective. Environ. Sci. Pollut. Res. https://doi.org/10.1007/s11356-022-21035-x (2022).
Beduk, T., Ait Lahcen, A., Tashkandi, N. & Salama, K. N. One-step electrosynthesized molecularly imprinted polymer on laser scribed graphene bisphenol a sensor. Sens. Actuators B Chem. 314, 128026. https://doi.org/10.1016/j.snb.2020.128026 (2020).
Zhu, J., Guo, X., Wang, H. & Song, W. Cost-effective fabrication and high-frequency response of non-ideal RC application based on 3D porous laser-induced graphene. J. Mater. Sci. 53, 12413–12420. https://doi.org/10.1007/s10853-018-2514-y (2018).
Luong, D. X. et al. Laser-induced graphene composites as multifunctional surfaces. ACS Nano 13, 2579–2586. https://doi.org/10.1021/acsnano.8b09626 (2019).
Yi, Y., Zhao, Y., Zhang, Z., Wu, Y. & Zhu, G. Recent developments in electrochemical detection of cadmium. Trends Environ. Anal. Chem. 33, e00152. https://doi.org/10.1016/j.teac.2021.e00152 (2022).
Jeong, S. E., Kim, S., Han, J. H. & Pak, J. J. Simple laser-induced graphene fiber electrode fabrication for high-performance heavy-metal sensing. Microchem. J. 172, 106950. https://doi.org/10.1016/j.microc.2021.106950 (2022).
Wang, F. et al. Laser-induced graphene: Preparation, functionalization and applications. Mater. Technol. 33, 340–356. https://doi.org/10.1080/10667857.2018.1447265 (2018).
Sánchez-Calvo, A., Blanco-López, M. C. & Costa-García, A. Paper-based working electrodes coated with mercury or bismuth films for heavy metals determination. Biosensors 10, 52. https://doi.org/10.3390/bios10050052 (2020).
Gupta, S. et al. Disposable bismuth-based electrodes for heavy metal ion detection. IOP Conf. Ser. Earth Environ. Sci. 228, 012014. https://doi.org/10.1088/1755-1315/228/1/012014 (2019).
He, Y. et al. Preparation and application of bismuth/MXene Nano-composite as electrochemical sensor for heavy metal ions detection. Nanomaterials 10, 866. https://doi.org/10.3390/nano10050866 (2020).
Song, Y. & Chen, J. Multifunctional bismuth-based materials for heavy metal detection and antibiosis. Bismuth Adv. Appl. Defects Charact. https://doi.org/10.5772/intechopen.75809 (2018).
Park, S., Maier, C. S. & Koley, D. Anodic stripping voltammetry on a carbon-based ion-selective electrode. Electrochim. Acta 390, 138855. https://doi.org/10.1016/j.electacta.2021.138855 (2021).
Álvarez-Martos, I., Henry, C. S. & Fernández Abedul, M. T. Anodic stripping voltammetric determination of lead and cadmium with stencil-printed transparency electrodes. Lab. Methods Dyn. Electroanal. https://doi.org/10.1016/B978-0-12-815932-3.00004-8 (2020).
Yi, W. J., Li, Y., Ran, G., Luo, H. Q. & Li, N. B. Determination of cadmium(II) by square wave anodic stripping voltammetry using bismuth–antimony film electrode. Sens. Actuators B Chem 166–167, 544–548. https://doi.org/10.1016/j.snb.2012.03.005 (2012).
Camila Ayala, M., Lorena López, L., Jaramillo-Botero, A. & Valencia, D. Electrochemical modified electrode with bismuth film for ultrasensitive determination of aluminum (iii). J. Electroan. Chem. 919, 116552. https://doi.org/10.1016/j.jelechem.2022.116552 (2022).
Tchounwou, P. B., Yedjou, C. G., Patlolla, A. K. & Sutton, D. J. Molecular, clinical and environmental toxicicology volume 3: Environmental toxicology. Mol. Clin. Environ. Toxicol. 101, 133–164. https://doi.org/10.1007/978-3-7643-8340-4 (2012).
Hui, X. et al. A nanocomposite-decorated laser-induced graphene-based multi-functional hybrid sensor for simultaneous detection of water contaminants. Anal. Chim. Acta 1209, 339872. https://doi.org/10.1016/j.aca.2022.339872 (2022).
Huang, J. H., Shetaya, W. H. & Osterwalder, S. Determination of (Bio)-available mercury in soils: A review. Environ. Pollut. 263, 114323. https://doi.org/10.1016/j.envpol.2020.114323 (2020).
Zhai, K. et al. Dual color fluorescence quantitative detection of mercury in soil with graphene oxide and dye-labeled nucleic acids. Anal. Methods 7, 3827–3832. https://doi.org/10.1039/c4ay03107e (2015).
Exley, C. The toxicity of aluminium in humans. Morphologie 100, 51–55. https://doi.org/10.1016/j.morpho.2015.12.003 (2016).
Rout, G. et al. Aluminium toxicity in plants: a review To cite this version: HAL Id: hal-00886101 Aluminium toxicity in plants: a review. Agronomie 21, 3–21 (2001).
He, H., Li, Y. & He, L. F. Aluminum toxicity and tolerance in Solanaceae plants. South Afr. J. Bot. 123, 23–29. https://doi.org/10.1016/j.sajb.2019.02.008 (2019).
Herawati, R., Ganefianti, D. W., Pujiwati, H., Purwoko, B. S. & Dewi, I. S. Assessment of aluminum tolerant of double haploid lines for developing new type of upland rice. Asian J. Agric. Biol. 2021, 1–10. https://doi.org/10.35495/ajab.2020.05.295 (2021).
Lidon, F. C. & Barreiro, M. G. Threshold aluminum toxicity in maize. J. Plant. Nutr. 21, 413–419. https://doi.org/10.1080/01904169809365413 (1998).
Chen, R. F., Shen, R. F., Gu, P., Wang, H. Y. & Xu, X. H. Investigation of Aluminum-tolerant species in acid soils of South China. Commun. Soil. Sci. Plant. Anal. 39, 1493–1506. https://doi.org/10.1080/00103620802006610 (2008).
Ringgit, G., Siddiquee, S., Saallah, S. & Mohamad Lal, M. T. Nanomaterial sensing advantages: Electrochemical behavior, optimization and performance of f-MWCNTs/CS/PB/AuE towards aluminum Ions (Al3+) in drinking water. Crystals 13, 497. https://doi.org/10.3390/cryst13030497 (2023).
Dilleen, J. W., Birch, B. J. & Haggett, B. G. Electrochemical detection of aluminium using single-use sensors. Anal. Commun. 36(11–12), 363–365. https://doi.org/10.1039/a907667k (1999).
Wu, S., Liang, Y. & Guo, H. An electrochemical sensor for sub-attomolar determination of aluminum ion with an ultra-wide response range. Microchem. J. 195, 109527. https://doi.org/10.1016/j.microc.2023.109527 (2023).
Rahman, M. A. et al. Importance of mineral nutrition for mitigating aluminum toxicity in plants on acidic soils: Current status and opportunities. Int. J. Mol. Sci. https://doi.org/10.3390/ijms19103073 (2018).
Rivera, Y., Moreno, L., Herrera, M. & Romero, H. M. La toxicidad por aluminio (Al3+) como limitante del crecimiento y la productividad agrícola: el caso de la palma de aceite. Palmas 37, 11–23 (2016).
de la Roche, J., López-Cifuentes, I. & Jaramillo-Botero, A. Influence of lasing parameters on the morphology and electrical resistance of polyimide-based laser-induced graphene (LIG). Carbon. Lett. 33, 587–595. https://doi.org/10.1007/s42823-022-00447-2 (2023).
Sophocleous, M. & Atkinson, J. K. A review of screen-printed silver/silver chloride (Ag/AgCl) reference electrodes potentially suitable for environmental potentiometric sensors. Sens. Actuators A Phys. 267, 106–120. https://doi.org/10.1016/j.sna.2017.10.013 (2017).
Zhou D.M., McAdams E.T., Lackermeier A., Jones J.G. AC impedance of Ag/AgCl reference electrodes for use in disposable biosensors. InProceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 832–3. https://doi.org/10.1109/IEMBS.1994.415168.
Wu, H. et al. Multielectrode arrays at wafer-level for miniaturized sensors applications: Electrochemical growth of Ag/AgCl reference electrodes. Sensors 23, 6130. https://doi.org/10.3390/s23136130 (2023).
Elgrishi, N. et al. A practical beginner’s guide to cyclic voltammetry. J. Chem. Educ. 95, 197–206. https://doi.org/10.1021/acs.jchemed.7b00361 (2018).
Bhuvaneswari, K., Radha, S., Sreeja, B. S. & Senthil, K. P. Development of in-situ electrochemical heavy metal ion sensor using integrated 1D/0D/1D hybrid by MWCNT and CQDs supported MnO2 nanomaterial. Environ. Res. 225, 115570. https://doi.org/10.1016/j.envres.2023.115570 (2023).
Anastasiadou, Z. D., Sipaki, I., Jannakoudakis, P. D. & Girousi, S. T. Square-wave anodic stripping voltammetry (swasv) for the determination of ecotoxic metals, using a bismuth-film electrode. Anal. Lett. 44, 761–777. https://doi.org/10.1080/00032711003790023 (2011).
Schneider, C. A., Rasband, W. S. & Eliceiri, K. W. NIH Image to ImageJ: 25 years of image analysis. Nat. Methods 9, 671–675. https://doi.org/10.1038/nmeth.2089 (2012).
Mackean S. Manual de Análisis de Suelos y Plantas. Cali, Colombia: (1993).
Wang, Z., Gang, L. & Yang, X. On-site determination of heavy metal in soil using electrochemical stripping analysis. Am. Soc. Agric. Biol. Eng. Annu. Int. Meet. 7, 5864–5877. https://doi.org/10.13031/2013.42215 (2012).
Zhao, G. & Liu, G. A portable electrochemical system for the on-site detection of heavy metals in farmland soil based on electrochemical sensors. IEEE Sens. J. 18, 5645–5655. https://doi.org/10.1109/JSEN.2018.2845306 (2018).
Krasnodȩbska-Ostrȩga, B. & Kowalska, J. Ultrasound-assisted acetic acid extraction of metals from soils. Chem. Analityczna. 48, 967–974 (2003).
Hacht, B. Speciation studies of aluminium(III)-acetate complexes under physiological conditions. Chem. Speciat. Bioavailab. 20, 207–215. https://doi.org/10.3184/095422908X379282 (2008).
Lukić, M. J., Wiedenbeck, E., Reiner, H. & Gebauer, D. Chemical trigger toward phase separation in the aqueous Al(III) system revealed. Sci. Adv. https://doi.org/10.1126/sciadv.aba6878 (2020).
Pohlmeier, A., Thesing, U. & Knoche, W. Formation of aluminium(III)-monocarboxylates in aqueous solution. Berichte Der Bunsengesellschaft Für Phys. Chemie 97, 10–15. https://doi.org/10.1002/bbpc.19930970103 (1993).
Ohto, K. et al. Comparative extraction of aluminum group metals using acetic acid derivatives with three different-sized frameworks for coordination. Separations 8, 19–22. https://doi.org/10.3390/separations8110211 (2021).
Li, C., Liu, W. & Ma, Y. Influence of H3O+ on the structure formation of oligomers in aluminium sols prepared from basic aluminium acetate: Experiments and computations. J. Mol. Liq. 289, 111052. https://doi.org/10.1016/j.molliq.2019.111052 (2019).
Ferrari, A. C. et al. Raman spectrum of graphene and graphene layers. Phys. Rev. Lett. 97, 187401. https://doi.org/10.1103/PhysRevLett.97.187401 (2006).
Yoon, D. et al. Variations in the Raman spectrum as a function of the number of graphene layers. J. Korean Phys. Soc. 55, 1299–1303. https://doi.org/10.3938/jkps.55.1299 (2009).
Cançado, L. G. et al. General equation for the determination of the crystallite size La of nanographite by Raman spectroscopy. Appl. Phys. Lett. 88, 163106. https://doi.org/10.1063/1.2196057 (2006).
Costentin, C., Hajj, V., Louault, C., Robert, M. & Savéant, J.-M. Concerted proton-electron transfers. Consistency between electrochemical kinetics and their homogeneous counterparts. J. Am. Chem. Soc. 133, 19160–19167. https://doi.org/10.1021/ja206561n (2011).
Costentin, C., Robert, M. & Savéant, J.-M. Concerted proton−electron transfers: Electrochemical and related approaches. Acc. Chem. Res. 43, 1019–1029. https://doi.org/10.1021/ar9002812 (2010).
Doherty, A. P. et al. Functional electro-materials based on ferricyanide redox-active ionic liquids. Electrochim. Acta 245, 934–940. https://doi.org/10.1016/j.electacta.2017.05.201 (2017).
Baldrianova, L., Svancara, I., Vlcek, M., Economou, A. & Sotiropoulos, S. Effect of Bi(III) concentration on the stripping voltammetric response of in situ bismuth-coated carbon paste and gold electrodes. Electrochim. Acta 52, 481–490. https://doi.org/10.1016/j.electacta.2006.05.029 (2006).
Trasatti, S. & Petrii, O. A. Surface area measurements. J. Electroanal. Chem. 327, 353–376. https://doi.org/10.1016/0926-860x(96)80148-7 (1991).
Xuan, X., Hossain, M. F. & Park, J. Y. A fully integrated and miniaturized heavy-metal-detection sensor based on micro-patterned reduced graphene oxide. Sci. Rep. 6, 33125. https://doi.org/10.1038/srep33125 (2016).
Pandey, S. K., Sachan, S. & Singh, S. K. Ultra-trace sensing of cadmium and lead by square wave anodic stripping voltammetry using ionic liquid modified graphene oxide. Mater. Sci. Energy Technol. 2, 667–675. https://doi.org/10.1016/j.mset.2019.09.004 (2019).
Li, X. et al. A novel design of engineered multi-walled carbon nanotubes material and its improved performance in simultaneous detection of Cd(II) and Pb(II) by square wave anodic stripping voltammetry. Sens. Actuators B Chem. 236, 144–152. https://doi.org/10.1016/j.snb.2016.05.149 (2016).
Chen, L. et al. Sensitive square wave anodic stripping voltammetric determination of Cd2+ and Pb2+ ions at Bi/Nafion/overoxidized 2-mercaptoethanesulfonate-tethered polypyrrole/glassy carbon electrode. Sens. Actuators B Chem. https://doi.org/10.1016/j.snb.2013.09.084 (2014).
Baldrianova, L., Agrafiotou, P., Svancara, I., Jannakoudakis, A. D. & Sotiropoulos, S. The effect of acetate concentration, solution pH and conductivity on the anodic stripping voltammetry of lead and cadmium ions at in situ bismuth-plated carbon microelectrodes. J. Electroanal. Chem. 660, 31–36. https://doi.org/10.1016/j.jelechem.2011.05.028 (2011).
Zhao, G., Wang, H. & Liu, G. Electrochemical determination of trace cadmium in soil by a bismuth film/graphene-β-cyclodextrin-nafion composite modified electrode. Int. J. Electrochem. Sci. 11, 1840–1851 (2016).
Pu, Y., Wu, Y., Yu, Z., Lu, L. & Wang, X. Simultaneous determination of Cd2+ and Pb2+ by an electrochemical sensor based on Fe3O4/Bi2O3/C3N4 nanocomposites. Talanta Open 3, 100024. https://doi.org/10.1016/j.talo.2020.100024 (2021).
Schmickler, W. & Santos, E. Interfacial electrochemistry. Interfacial. Electrochem https://doi.org/10.1007/978-3-642-04937-8 (2010).
Wang, J. Stripping analysis at bismuth electrodes: A review. Electroanalysis 17, 1341–1346. https://doi.org/10.1002/elan.200403270 (2005).
Streeter, I., Wildgoose, G. G., Shao, L. & Compton, R. G. Cyclic voltammetry on electrode surfaces covered with porous layers: An analysis of electron transfer kinetics at single-walled carbon nanotube modified electrodes. Sens. Actuators B Chem. 133, 462–466. https://doi.org/10.1016/j.snb.2008.03.015 (2008).
Dossi, C., Monticelli, D., Pozzi, A. & Recchia, S. Exploiting chemistry to improve performance of screen-printed, bismuth film electrodes (SP-BiFE). Biosensors 6, 38. https://doi.org/10.3390/bios6030038 (2016).
Guo, Y., Zhang, C., Chen, Y. & Nie, Z. Research progress on the preparation and applications of laser-induced graphene technology. Nanomaterials 12, 2336. https://doi.org/10.3390/nano12142336 (2022).
Navalon, S., Dhakshinamoorthy, A., Alvaro, M., Antonietti, M. & García, H. Active sites on graphene-based materials as metal-free catalysts. Chem. Soc. Rev. 46, 4501–4529. https://doi.org/10.1039/c7cs00156h (2017).
Lee, H., Sitapure, N., Hwang, S. & Kwon, J. S. I. Multiscale modeling of dendrite formation in lithium-ion batteries. Comput Chem Eng 153, 107415. https://doi.org/10.1016/j.compchemeng.2021.107415 (2021).
Hoffman, Z. B. et al. High selectivity towards formate production by electrochemical reduction of carbon dioxide at copper-bismuth dendrites. ChemSusChem 12, 231–239. https://doi.org/10.1002/cssc.201801708 (2019).
Anh, N. H. et al. Role of Br- on the formation of a bismuth nanodendrite structure and its use as an electrochemical sensor for heavy metal detection. Int. J. Electrochem. Sci. 15, 5373–5384. https://doi.org/10.20964/2020.06.45 (2020).
He, L., Sun, Q., Lu, L. & Adams, S. Understanding and preventing dendrite growth in lithium metal batteries. ACS Appl. Mater. Interfaces 13, 34320–34331. https://doi.org/10.1021/acsami.1c08268 (2021).
Qi, X. et al. Removal of cadmium and lead from contaminated soils using sophorolipids from fermentation culture of starmerella bombicola CGMCC 1576 fermentation. Int. J. Environ. Res. Public Health 15, 2334. https://doi.org/10.3390/ijerph15112334 (2018).
José Rodrigues Cruz, F. et al. Copper Toxicity in Plants: Nutritional, Physiological, and Biochemical Aspects (Plant Def. Mech., IntechOpen, Adv, 2022). https://doi.org/10.5772/intechopen.105212.
Yang, D., Wang, L., Chen, Z., Megharaj, M. & Naidu, R. Investigation of copper(II) interference on the anodic stripping voltammetry of lead(II) and cadmium(II) at bismuth film electrode. Electroanalysis 25, 2637–2644. https://doi.org/10.1002/elan.201300375 (2013).
Pizarro, J. et al. Inexpensive and green electrochemical sensor for the determination of Cd(II) and Pb(II) by square wave anodic stripping voltammetry in bivalve mollusks. Food. Chem. 321, 126682. https://doi.org/10.1016/j.foodchem.2020.126682 (2020).
Li, H., Zhao, J., Zhao, S. & Cui, G. Simultaneous determination of trace Pb(II), Cd(II), and Zn(II) using an integrated three-electrode modified with bismuth film. Microchem. J. 168, 106390. https://doi.org/10.1016/j.microc.2021.106390 (2021).
de Oliveira, A. P., Milani, R. F., Efraim, P., Morgano, M. A. & Tfouni, S. A. Cd and Pb in cocoa beans: Occurrence and effects of chocolate processing. Food Control. 1(119), 107455. https://doi.org/10.1016/j.foodcont.2020.107455 (2021).
Lo Dico, G. M. et al. Toxic metal levels in cocoa powder and chocolate by ICP-MS method after microwave-assisted digestion. Food Chem. 245, 1163–1168. https://doi.org/10.1016/j.foodchem.2017.11.052 (2018).
Vanderschueren, R. et al. Mitigating the level of cadmium in cacao products: Reviewing the transfer of cadmium from soil to chocolate bar. Sci. Total Environ. 781, 146779. https://doi.org/10.1016/j.scitotenv.2021.146779 (2021).
de Campos, A. M., Silva, R. R., Calegaro, M. L. & Raymundo-Pereira, P. A. Design and fabrication of flexible copper sensor decorated with bismuth micro/nanodentrites to detect lead and cadmium in noninvasive samples of sweat. Chemosensors https://doi.org/10.3390/chemosensors10110446 (2022).
Kadara, R. O. & Tothill, I. E. Resolving the copper interference effect on the stripping chronopotentiometric response of lead(II) obtained at bismuth film screen-printed electrode. Talanta 66, 1089–1093. https://doi.org/10.1016/j.talanta.2005.01.020 (2005).
Oorts K. Copper. Environ. Pollut., (2013), p. 367–94. https://doi.org/10.1007/978-94-007-4470-7_13.
Schulte E.E., Kelling K.A. Soil and applied copper. Underst. Plant. Nutr. Ser. 6–7 (1999).
Kobayashi, Y. et al. Molecular and physiological analysis of Al3+ and H+ Rhizotoxicities at moderately acidic conditions. Plant. Physiol. 163, 180–192. https://doi.org/10.1104/pp.113.222893 (2013).
Jaiswal, S. K., Naamala, J. & Dakora, F. D. Nature and mechanisms of aluminium toxicity, tolerance and amelioration in symbiotic legumes and rhizobia. Biol. Fertil. Soils 54, 309–318. https://doi.org/10.1007/s00374-018-1262-0 (2018).
Acknowledgements
This work was partially funded by the OMICAS Alliance (Optimización Multiescala In-silico de Cultivos Agrícolas Sostenibles), part of the Scientific Colombia ecosystem, sponsored by the World Bank, the Colombian Ministry of Science, Technology, and Innovation (MINCIENCIAS), ICETEX, the Colombian Ministry of Education and the Colombian Ministry of Commerce, Industry and Tourism (under Grant id: FP44842-217-2018, award ID: 792-61187).
Funding
World Bank PACES program, P160446.
Author information
Authors and Affiliations
Contributions
A.J.B. and D.P.V. conceived this work. V.R. performed electrochemical experiments, J.D.R. and E.H.R. contributed to S.E.M. and E.D.X. characterization. T.G. contributed to soil extraction protocol. O.I. and M.D.S. contributed to characterize reference soils. V.R. and A.J.B. wrote the initial draft. All authors contributed to the analysis and writing and approved the final version of this manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Reyes-Loaiza, V., De La Roche, J., Hernandez-Renjifo, E. et al. Laser-induced graphene electrochemical sensor for quantitative detection of phytotoxic aluminum ions (Al3+) in soils extracts. Sci Rep 14, 5772 (2024). https://doi.org/10.1038/s41598-024-56212-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-024-56212-0
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.