Abstract
A novel metal-doped Zn/Cl carbon quantum dots (Zn/Cl-CQDs) was developed successfully as ratiometric fluorescent probes for the sequential on-off-on detection of riboflavin, Cu2+ ion and thiamine. The excellent catalytic performance of the Zn/Cl-CQDs nanozyme serves as an ideal platform for sensitive detection of thiamine. Due to the addition of riboflavin to the Zn/Cl-CQDs, the blue emission peak of Zn/Cl-CQDs at 440 nm remains unaffected and used as an internal reference approach, while the green emission peak of riboflavin at 520 nm appeared and increased remarkably. Following the presence of Cu2+, a quenching blue fluorescence signal of Zn/Cl-CQDs was observed which resulted in consequent fluorescent ‘turn-off’ response toward Cu2+ ion. Finally, upon the addition of thiamine to the above solution under alkaline condition, the blue emission of Zn/Cl-CQDs was gradually recovered. The prepared Zn/Cl-CQDs could act as a nanozyme catalyst for directly catalyzing the oxidation of non-fluorescent substrate of thiamine to produce highly fluorescent substrate of thiochrome. As a result, the blue fluorescence emission peak at 440 nm was recovered. Eventually, the sequential detection properties of ratiometric probes for riboflavin, Cu2+ ion and thiamine were successfully applied in VB2 tablets, drinking water and VB1 tablet with good recoveries of 96.21%, 98.25% and 98.44%, respectively.
Similar content being viewed by others
Introduction
In recent years, development of metal-doped carbon quantum dots (CQDs) has attracted much attention and become an effective strategy to adjust their surface chemical reactivities and electronic properties in many applications from separation science and detection of analytes1,2. Up to now, some articles have been reported about catalytic performance of metal-doped carbon quantum dots3. Duan et al. have developed Cu-doped CQDs (Cu-CQDs) as the catalyst for chemiluminescence detection of glucose4. Iron and nitrogen co-doped carbon dots (Fe-N-CQDs) were prepared by Yang’s group. The nanozyme, Fe-N-CQDs exhibited a superior peroxidase activity due to the iron doping and were successfully applied in immunosorbent assay5.
The measurements with single emission fluorescence probe can be affected by different external factors such as light scattering of the sample matrix, temperature fluctuation, excitation intensity drift, variation in the probe concentration, environment and solvent system. To overcome these undesirable effects, the construction of ratiometric fluorescent probes as an excellent candidate for biochemical/chemical sensing platform has attracted wide attention6. Contrary to conventional methods of single emission fluorescence for biochemical/chemical detection, the ratiometric fluorescence methods include an intrinsic built-in self-calibration for correction of interferences arisen from background and sample matrix. In ratiometric fluorescence probes, fluorescence intensity of the analytes changes from two or multi-emission bands at various wavelengths, which can provide reliable and accurate quantitative analysis7,8.
In recent years, carbon dots have presented convenient platforms to design and construct ratiometric fluorescent probes. In ratiometric fluorescent probes based on CQDs, there are two major strategies for constructing dual-emission ratiometric fluorescent probes. One is to apply the CQDs as a reference signal which does not respond to the analyte. The other is to introduce CQDs as response signals that are sensitive to analyte and respond to the analyte under optimal conditions7,9,10. In many literatures based on CQDs ratiometric fluorescent probes, the CQDs were used as either analyte-response11,12 or reference unit13,14. Typically, these CQDs-based ratiometric fluorescent probes have been extended with a series of nanohybrid of CQDs with other organic dyes such as Rhodamine15, metal organic framework (MOF)16, nanoclusters (AuNCs and CuNCs)17,18 and various QDs (carbon-based quantum dots, semiconductor quantum dots CdTe19 and CdSe20) for different analytes. All results from the articles confirmed that the target analytes were determined with good selectivity, high accuracy and reproducibility, based on the self-calibration and background correction due to the fluorescence intensity ratio of emission peaks from the response and reference signals.
However, the construction of the sequential multi-component detection of analytes based on ratiometric fluorescent probes is a major challenge because it requires two or more fluorophore groups to be excited by the same excitation wavelength. Additionally, the construction of ratiometric fluorescent probes is not straightforward and does not involve a simple mixing procedure. Due to the importance of simultaneous detection of multiple analytes in different matrices, synthesis and design of biochemical/chemical probes for sequential multi-component detection of analytes have recently drawn great attention9,16,21,22. Generally, these sensors could respond to multiple ions23 or small molecules24, even some of them can sequentially detect ions or molecules25.
Copper ion (Cu2+), Riboflavin (Vitamin B2) and thiamine (Vitamin B1) are three components that are quite related to our environment and lives. Riboflavin, commonly referred to vitamin B2, is an important water-soluble vitamin and plays an essential role in the normal functioning of the body by participating in the normal metabolism of proteins, carbohydrates, fats and cellular processes. Riboflavin cannot be generated by the human body, and it can merely be obtained from food or pharmaceutical supplements26,27,28.
Copper is the most abundant metal in the human body, and has an essential role in ferroxidase, cytochrome oxidase and superoxide dismutase as a cofactor enzyme. This essential element can help to produce red blood cells and support transcriptional events in human body. However, the accumulation of excess amounts of copper Cu2+ can interrupt the balance between cells, which leads to a category of illnesses such as Menkes, Wilson, Parkinson’s and Alzheimer’s diseases. The accumulation of excess amounts of Cu2+ in the body leads to gastrointestinal disorders and liver or kidney disorders19,29,30. Cu2+ can also cause environmental pollution due to its widespread use in agriculture and industry. Hence, according to the WHO guidelines, the maximum allowable level of Cu2+ in drinking water is 2 mg L−1 (32 μM). Therefore, it is very important to develop an efficient and accurate method to detect Cu2+ ion, particularly in drinking water monitoring31.
Thiamine, a sulfur-containing water-soluble vitamin and natural nutrient is present in many foods. Thiamine has an essential role in the metabolism of enzymes, brain health especially in emotional well-being, concentration and focus. Thiamine deficiency causes various illnesses in the human body such as beriberi, nervous and cardiovascular problems. Since this compound is only synthesized by bacteria, fungi and plants, adequate dietary intakes are necessary. Therefore, the development of an accurate, convenient and sensitive method for determination of vitamin B1 in food and pharmaceutical supplements is crucial32,33.
As far as we know, this is the first study to offer insights into the implementation of proper analytes sequence as part of response or reference units in ratiometric fluorescent probe develpment. Moreover, superior catalyst activity of Zn/Cl-CQDs as a nanozyme for directly catalyzing the oxidation of thiamine were demonstrated.
In this study, proper selection of analytes, their rational combinations and sequence detection under optimal condition for design and construction of new ratiometric fluorescent probes were evaluated. In other words, the addition of the first analytes to the CQDs probe can act as a reference or response signal for the detection of subsequent analytes. As a result, we aimed to design a ratiometric fluorescent probe based on CQDs for sequential monitoring of riboflavin, Cu2+ ion and thiamine in real samples, which enriches the range of CQDs applications within various fields of chemical and biological assays.
Experimental
Materials and instruments
Thiamine hydrochloride, Pyridoxine hydrochloride (vitamin B6), calcium D-pantothenate (vitamin B5), ascorbic acid (vitamin C), NaOH, NaCl, KCl, ZnCl2, PbCl2, FeCl2, MnCl2, CrCl2, CdCl2, CoCl2, MgCl2, CaCl2 were bought from Merck (Darmstadt, Germany). Riboflavin, niacin (vitamin B3) and zinc gluconate were purchased from Sigma-Aldrich.
For all spectroscopic and experimental studies, Milli-Q water (0.05 μScm−1) was used. Fluorescence spectra were obtained on LS-55 Perkin Elmer fluorescence spectrophotometer from 370 to 800 nm. The IR spectra of Zn/Cl-CQDs was performed on FT-IR Spectrum two model Perkin Elmer from 400 to 4000 cm−1.The electron microscopy of Zn/Cl-CQDs was conducted using a SEM (ZEISS with EDS and Mapping) and high-resolution FEI Tecnai F20 TEM.
Synthesis of Zn/Cl-doped CQDs by microwave-assisted method
A novel carbon quantum dots co-doped with metal and non-metal elementals, zinc and chlorine, (Zn/Cl-CQDs) was prepared by one-pot microwave-assisted method with zinc gluconate and hydrochloric acid. Briefly, 1 g of zinc gluconate was firstly weighed and added to 10 mL of ultrapure water and stirred for 10 min. Then, the pH of the mixture was adjusted to about 4 using HCl solution. The solution was then placed in the microwave radiation system at temperature 160 °C for 10 min. Finally, the color of the solution turned to orange, which confirmed the formation of Zn/Cl-CQDs. Then the pH of the final solution was neutralized and the Zn/Cl-CQDs solution was stored in 4 °C for further use.
Detection procedure for sequential fluorescent detection
Initially, stock solutions of riboflavin, Cu2+ ion and thiamine were prepared in ultrapure water at a high concentration and further diluted. The Zn/Cl-CQDs nanosensor was utilized for sequential detection of riboflavin, Cu2+ ion and thiamine.
1 mL of Zn/Cl-CQDs nanosensor and 3.8 mL of ultrapure water were added into a 5 mL test tube. Then, 200 μL of riboflavin working solutions with various concentrations were added into above solution. Then the fluorescence spectra of the solution were measured from 370 to 800 nm by fluorescence spectrophotometer at excitation wavelength 366 nm. Under optimal condition, Zn/Cl-CQDs and riboflavin system were used for sequential detection of Cu2+ ion. 1 mL of Zn/Cl-CQDs solution and 3.6 mL of ultrapure water, 200 μL of riboflavin (500 nM) were added into a 5 mL tube. Then, 200 μL of Cu2+ ion working solutions with various concentrations were added into above solution and the fluorescence intensities of the mixture solution were measured from 370 to 800 nm. Finally, the quantitative detection of thiamine using above system was performed as follows: 1 mL of Zn/Cl-CQDs solution, 200 μL of riboflavin, 200 μL of Cu2+ ion (160 µM) and 200 μL of thiamine with different concentrations, 800 μL NaOH (0.05 mM) and 2.6 mL of ultrapure water were added into a 5 mL tube. The fluorescence intensities of the mixture solution were measured from 370 to 800 nm. To evaluate the linearity and limit of detection for the sequential detection of riboflavin, Cu2+ ion and thiamine, the spectra of fluorescence intensities of the Zn/Cl-CQDs with different concentrations of the analytes were recorded.
Real samples preparation
VB2 (riboflavin) and VB1 (thiamine) tablets were purchased for real samples evaluation. Tablets were ground into powder and dissolved in 100 mL water. The solution was centrifuged at 10,000 rpm for 10 min to remove the undissolved substances. Then the upper solution was filtered through a 0.45 μm filter membrane. The sample solution was further diluted in order to prepare appropriate concentrations of analytes for the quantitative analysis. Bottles of drinking water were purchased from supermarket and analyzed without any further pre-treatment.
Results and discussion
Characterization of Zn/Cl-CQDs
The morphology and elemental analysis of Zn/Cl-CQDs were performed by the SEM instrument equipped with EDX spectroscope. Figure 1A reveals spherical morphology of the Zn/Cl-CQDs. Moreover, EDX analysis and mapping exhibited the exact composition and distribution of doped elements in details. As shown in Fig. 1D, EDX mapping, the uniform and successful doping of Zn and Cl elements in the structure of Zn/Cl-CQDs were confirmed. In addition, Fig. 1C indicates that C, O, Zn and Cl elements were homogeneously distributed throughout the structure of synthesized Zn/Cl-CQDs. As a result, high efficiency of elemental doping through microwave assisted synthesis strategy, led to uniform distribution of elements in the structure of Zn/Cl-CQDs. The morphology and structure of Zn/Cl-CQDs are shown in Fig. 1B. The TEM image shows that the average size distribution of Zn/Cl-CQDs is mainly smaller than 20 nm. On the other hand, analysis of TEM image by ImageJ software showed the distribution size of 0–17 nm with the average of about 9 nm.
The surface structure and composition of Zn/Cl-CQDs were further evaluated by FT-IR (Fig. 1E). In the FT-IR spectra of the Zn/Cl-CQDs, a broad absorption band at about 3000–3500 cm−1could be attributed to the stretching vibration of O–H groups4. Moreover, the peaks at 1220 cm−1, 1022 cm−1 and 1133 cm−1 were assigned to the asymmetric and symmetric stretching vibrations of C − O and the stretching vibration of the C − O − C, respectively. The FT-IR spectra of Zn/Cl-CQDs also showed absorption peaks at around 2936 cm−1 and 2887 cm−1 which were related to stretching and bending vibrations of methylene (− CH2) groups34. It should be noted thatthe important functional bands at 753 cm−1 and 561 cm−1were related to the stretching vibrations of Zn–O and C–Cl bands, indicating the successful doping of zinc and chlorine elements in the CQDs35,36. The FT-IR results were in agreement with other characterization results and proved that Zn/Cl-CQDs mainly contained hydroxyl, carbonyl, carboxylic acid, epoxy groups on its surface and also indicated that Cl and Zn heteroatoms were successfully doped.
Sequential detection of riboflavin, Cu2+ ion and thiamine based on Zn/Cl-CQDs
The potential of Zn/Cl-CQDs as a new ratiometric fluorescent probe for monitoring of riboflavin was evaluated. As shown in Fig. 2A, a new green emission peak at 520 nm appeared and increased remarkably by the gradual addition of riboflavin to the Zn/Cl-CQDs solution; while the blue emission peak of Zn/Cl-CQDs at 440 nm remained unaffected or was accompanied by very small changes. In the designed sensors for detection of riboflavin, the Zn/Cl-CQDs could be served as an internal reference unit that is target insensitive, while a new emission peak of riboflavin at 520 nm appeared and increased. A suitable linear relation between the ratio of the relative fluorescence intensities of green to blue emission peaks (Fgreen/Fblue) with concentration of riboflavin was obtained in the range of 50–1000 nM (Fig. 2B). The equation of calibration curve was (Fgreen/Fblue) = 0.0012x + 0.1481 with a good correlation coefficient (0.9911) and limit of detection (14.12 nM).
Then sequential detection of Cu2+ ion using the Zn/Cl-CQDs /riboflavin system was investigated. As displayed in Fig. 3A, when the concentration of Cu2+ ion in the Zn/Cl-CQDs/riboflavin solution increased, the fluorescence signal at blue and green wavelengths gradually decreased. The difference was that the decrease in fluorescence signal occurred more intensely in the blue wavelength than green. A suitable linear relation was obtained between the ratio of the fluorescence intensities of blue wavelength to the green peaks (∆FBlue/Fgreen) and concentration of Cu2+ ion in the range of 0.162–48.75 µM (Fig. 3B). The equation of the calibration curve was (∆FBlue/Fgreen) = 0.0351x + 0.2349 with a good correlation coefficient (0.9917) and limit of detection (0.0543 µM).
Thiamine as the third analyte was selected to prove sequential detection performance of the designed probes. Finally, increasing the concentration of thiamine to the above probe solution in alkaline conditions and in the presence of copper resulted in recovery of the blue fluorescence emission corresponding to CQDs, while the change in fluorescence signal of the green wavelength was negligible (Fig. 4A). There were two linear ranges from 0.05–0.25 μM and 0.25–12.5 μM for thiamine (Fig. 4B,C) related to the linear equations of Fblue/Fgreen = 6.7984 C + 1.6529 (R2 = 0.9963) and Fblue/Fgreen = 0.1406 C + 3.3577 (R2 = 0.9908), respectively.
A comprehensive comparison of the fluorescent probes for the detection of riboflavin, Cu2+ ion and thiamine were also performed and listed in Table 1. The sequential multi-component detection of analytes based on new Zn/Cl-CQDs probes exhibited high sensitivity, good linear range and low limit of detection which was better than the compared resources (Table 1).
In order to investigate the practical nanozyme catalyst activity of the introduced Zn/Cl-CQDs, the fluorescence spectra of thiamine in the absence and presence of Zn/Cl-CQDs were recorded and exhibited in Fig. 4D. In the present investigation, it was found that a non-fluorescent substrate of thiamine could be oxidized into a fluorescent substrate of thiochrome by copper ion in the presence of Zn/Cl-CQDs as catalyst. As shown in Fig. 4D, this phenomenon was not observed in the absence of Cu2+ ion and Zn/Cl-CQDs. The results proved that the design of Zn/Cl-CQDs and proper selection of analytes (Cu2+ ion and thiamine) and their rational combinations under optimal condition could lead to construction of desirable sequential multi-component detection of analytes based on on–off-on strategy of ratiometric probes.
Wavelengths selection for ratiometric fluorescence detection
The excitation-dependent fluorescence emission features of the Zn/Cl-CQDs/Riboflavin were studied by fluorescence spectroscopy. As exhibited in Fig. 5, Zn/Cl-CQDs /riboflavin solution consisted of two emission peaks observed at 440 nm and 520 nm under various excitation wavelengths from 306 to 386 nm. It was clearly shown that the intensities of the emission peaks at 440 and 520 nm gradually increased with changing the excitation wavelength from 306 to 366 nm. Then, by increasing the excitation wavelength from 366 to 386 nm, the fluorescence intensities of both wavelengths related to carbon dot and riboflavin decreased in 440 nm and 520 nm, respectively. Therefore, the maximum fluorescence emission intensities of both Zn/Cl-CQDs and Riboflavin were observed at excitation wavelength of 366 nm. Moreover, 366 nm was selected as the optimal excitation wavelength.The results in Fig. 5 demonstrated that the Zn/Cl-CQDs /riboflavin had a great potential for designing dual emission ratiometric fluorescent probes, which could be achieved with an optimum single excitation wavelength (366 nm) for the subsequent detection of analytes.
Mechanism description
Riboflavin
In the designed sensors for detection of riboflavin, the blue emission peak of Zn/Cl-CQDs at 440 nm remainen unaffected and was used as an internal reference approach, while riboflavin was directly detected by measuring its own emission at 520 nm. This ratiometric fluorescence method for the detection of riboflavin led to self-calibration for correction of interferences arisen from background and detection systems, which was based on the changes in the ratio of two emission peaks of response/reference units (Fgreen/Fblue).
Cu2+
Then sequential detection of Cu2+ ion using the Zn/Cl-CQDs /riboflavin system was investigated. As displayed in Fig. 3A, when the concentration of Cu2+ion increased,the fluorescence signal gradually decreased. Cu2+ is an electron acceptor and exhibits a strong affinity with the oxygen group37. The quenching mechanism could be mainly due to a photoinduced electron transfer (PET) process from excited C-dots to the empty d orbits of Cu2+38. Also, investigation on the surface properties of Zn/Cl-CQDs by the FT-IR revealed the presence of hydroxyl and carboxyl group of CQDs, suggested the possible preferential probability of coordination with Cu2+ and quenching fluorescence by an electron transfer mechanism.
Thiamine
The catalytic performances of metal-doped carbon quantum only could be found in a few studies39,40. Zinc, an important element assisting the electron-transfer process could be a promising metal dopant for CQDs, which indicated catalytic performances due to the higher oxidation state of Zn in the whole CQDs structures40. The possible mechanism for detection of thiamine can be explained by this fact that the non-fluorescent substrate of thiamine could be oxidized to a blue fluorescent product of thiochrome in the presence of catalyst or oxidizing agent in alkaline condition41.
In these studies, the catalytic activities of the Zn/Cl-CQDs were evaluated by the quantification of oxidation product of thiamin named as thiochrome with fluorescence properties and detected via fluorescence spectroscopy. To investigate the practical nanozyme catalyst activity of the introduced Zn/Cl-CQDs, the fluorescence spectra of thiamine in the absence and presence of Zn/Cl-CQDs were recorded and exhibited in Fig. 4D.
Finally, upon the addition of thiamine to the above solution under alkaline condition resulted in the gradual recovery of Zn/Cl-CQDs blue emission. The prepared Zn/Cl-CQDs could act as a nanozyme catalyst for directly catalyzing the oxidation of non-fluorescent substrate of thiamine to produce highly fluorescent substrate of thiochrome, thus the blue fluorescence emission peak at 440 nm was recovered.
Interference and selectivity studies
The effect of different common substances used in the formulation of supplements was evaluated as interfering factor in accurate determination of riboflavin. Vitamin C, B3, B5 with concentration of 5000 nM were used as competitive water-soluble vitamins for selectivity studies of the probes for riboflavin (500 nM). As shown in Fig. 6A, no change or a slight change (< 4%) in the fluorescence signal of sensor (Fgreen/Fblue) was observed for riboflavin monitoring in the presence of other vitamins. The results confirmed that, even at concentrations 10 times that of the interfering vitamins, it has little effect on the riboflavin detection.
In order to examine the selectivity of the probes for Cu2+ ion, the fluorescence response of Zn/Cl-CQDs /riboflavin solution probe was verified in the presence of different metal ions (including Na+, K+, Zn2+, Pb2+, Fe2+, Mn2+, Cr2+, Cd2+, Co2+, Mg2+, Ca2+). As shown in Fig. 6C, the addition of these metal ions with concentration of 325 µM caused no apparent changes (< 6%) on the fluorescence signal of the sensor (∆FBlue/Fgreen), indicating that the probes have a good selectivity for detection of Cu2+ (32.5 µM) in the presence of other metal ion interferes even at tenfold concentrations in drinking water.
To evaluate the sensitivity and selectivity of the designed probe in the presence of other interferences, the potential of interfering effects of other vitamins were tested. As shown in Fig. 6B, no apparent changes (< 3%) of fluorescence intensity ratio (Fblue/Fgreen) were found after the introduction of other vitamins (C, B3, B5) with concentration of 1.6 µM as interfering substances for selectivity studies of the probes for thiamine (0.16 µM). The investigation proved that the probe had good anti-interference properties for the detection of thiamine in real samples.
Photostability and stability studies
The photostability of Zn/Cl-CQDs were investigated. The photostability was monitored by recording fluorescence spectra of Zn/Cl-CQDs under continuous UV irradiation at different time intervals. The results (Fig. S1) indicated that only ≤ 4% change in fluorescence intensity of the N-B CQDs were observed during 300 min. In addition, the Zn/Cl-CQDs solution has good stability (≤ 6% change in fluorescence intensity) and can be preserved away from light for at least 2 month at a refrigerator (4 °C).
Moreover, the stability of Zn/Cl-CQDs was studied by investigating the influences of pH (3- 11), and concentration of NaCl (0.1–1 M) (Fig. S2). As shown in Fig. S2A, the fluorescence intensities were decreased at the pH from 7 to 11 for both Zn/Cl-CQDs and riboflavin. Whereas the ratio of fluorescence intensities (Fgreen/Fblue) exhibited negligible changes (Fig. S2B). Therefore, stability of Zn/Cl-CQDs was almost independent on the pH values and could be applied at a broad pH range. But in these studies, pH 7 was chosen as optimum for further experiment. Moreover, the stability of the Zn/Cl-CQDs under various ionic (0.1–1 mol/L NaCl) strengths was also investigated (Fig. S3), and it was found that the fluorescence intensity of Zn/Cl-CQDs has no obvious changes.
Real samples multi-component detection
In order to evaluate the practical applicability of the designed probe for sequential determination of riboflavin, Cu2+ ion and thiamine, VB2 tablet, drinking water and VB1 tablet were used as real samples, respectively. Table 2 indicates spiked and recovery results obtained by the ratiometric fluorescent probes for sequential multi-component detection of analytes in VB2 tablet, drinking water and VB1 tablet. In the real samples, the recovery results were in the range 93.14–98.44% with RSD between 1.65 and 2.84% (n = 3). The analytical results indicated a high level of agreement with their spiked value and label/manufacture’s claims.
Conclusion
Sequential multi-component detection of riboflavin, Cu2+ ion and thiamine based on Zn/Cl-doped CQDs ratiometric fluorescent probes have special advantage than other fluorescent probes, because it can effectively eliminate or reduce background interferences thorough internal calibration and also provide the simultaneous detection of multiple analytes in different complicated matrices. Also, satisfying recovery results which were in agreement with their label/manufacture’s claims of VB2, VB1 tablets and spiked value of drinking water, proved the potential of designed platform for sequential multi-component detection of different analytes. Moreover, development of a metal-doped carbon dots such as novel Zn/Cl-CQDs, effectively adjusted their chemical reactivities and luminescence properties and also exhibited superior nanozyme catalyst activity in oxidation of the non-fluorescent substrate of thiamine to produce fluorescent substrate of thiochrome. More importantly, a new sequential ratiometric probe based on nanozyme catalyst activity of Zn/Cl-CQDs was constructed for highly sensitive and selective fluorescent turn-on response toward thiamine detection. According to this property of Zn/Cl-CQDs, upon the addition of thiamine to the probe solution, the blue emission of Zn/Cl-CQDs gradually recovered due to the produced fluorescent substrate of thiamine named as thiochrome. Moreover, subsequently a new sequential “turn-on” strategy was designed for accurate and sensitive detection of thiamine. This is a new concept for performance of ratiometric assays demonstrated with a Zn/Cl-CQDs-based catalyst activity which provides a basis for multi-component analysis as a new nanosensor platform for the future studies. Considering easy operation and high accuracy of these fluorescent sensors, the metal-doped CQDs can be promising in monitoring various analytes in drugs, water quality and body fluids.
Data availability
All data generated or analysed during this study are included in this published article [and its supplementary information files].
References
Kailasa, S. K. et al. Perspectives of magnetic nature carbon dots in analytical chemistry: From separation to detection and bioimaging. Trends Environ. Anal. Chem. 33, e00153 (2022).
Kailasa, S. K. et al. Microwave-assisted synthesis of water-soluble Eu 3+ hybrid carbon dots with enhanced fluorescence for the sensing of Hg 2+ ions and imaging of fungal cells. New J. Chem. 42, 6125–6133 (2018).
Lin, L. et al. Metal ions doped carbon quantum dots: Synthesis, physicochemical properties and their applications. Trends Anal. Chem 103, 87–101 (2018).
Duan, Y. et al. Cu-doped carbon dots as catalysts for the chemiluminescence detection of glucose. ACS Omega 4, 9911–9917 (2019).
Yang, W. et al. High peroxidase-like activity of iron and nitrogen co-doped carbon dots and its application in immunosorbent assay. Talanta 164, 1–6 (2017).
Bigdeli, A. et al. Ratiometric fluorescent nanoprobes for visual detection: Design principles and recent advances—A review. Anal. Chim. Acta 1079, 30–58 (2019).
Yan, F. et al. Ratiometric fluorescence probes based on carbon dots. Curr. Org. Chem 22, 57–66 (2018).
Doussineau, T. et al. On the design of fluorescent ratiometric nanosensors. Chem. Eur. J. 16, 10290–10299 (2010).
Gui, R. et al. Recent advances in dual-emission ratiometric fluorescence probes for chemo/biosensing and bioimaging of biomarkers. Coord. Chem. Rev. 383, 82–103 (2019).
Huang, X. et al. “Three-in-one” nanohybrids as synergistic nanoquenchers to enhance no-wash fluorescence biosensors for ratiometric detection of cancer biomarkers. Theranostics 8, 3461 (2018).
Lu, S. et al. Carbon dots-based ratiometric nanosensor for highly sensitive and selective detection of mercury (II) ions and glutathione. RSC Adv. 6, 103169–103177 (2016).
Zhu, A. et al. Carbon-dot-based dual-emission nanohybrid produces a ratiometric fluorescent sensor for in vivo imaging of cellular copper ions. Angew. Chem. Int. Ed. 51, 7185–7189 (2012).
Yan, Y. et al. Dual-emissive nanohybrid of carbon dots and gold nanoclusters for sensitive determination of mercuric ions. Nano Res. 9, 2088–2096 (2016).
Ye, Z. et al. Preparation of europium complex-conjugated carbon dots for ratiometric fluorescence detection of copper (II) ions. New J. Chem. 38, 5721–5726 (2014).
Liang, Y.-C. et al. A ratiometric fluorescent nanoprobe based on quenched carbon dots-rhodamine B for selective detection of L-cysteine. J. Alloys Compd. 788, 615–622 (2019).
Yang, L., Song, Y. & Wang, L. Multi-emission metal–organic framework composites for multicomponent ratiometric fluorescence sensing: Recent developments and future challenges. J. Mater. Chem. B 8, 3292–3315 (2020).
Yang, Y. et al. A novel and sensitive ratiometric fluorescence assay for carbendazim based on N-doped carbon quantum dots and gold nanocluster nanohybrid. J. Hazard. Mater. 386, 121958 (2020).
He, Y.-S. et al. Highly sensitive and selective dual-emission ratiometric fluorescence detection of dopamine based on carbon dots-gold nanoclusters hybrid. Sens. Actuators B 265, 371–377 (2018).
Rao, H. et al. Silica-coated carbon dots conjugated to CdTe quantum dots: A ratiometric fluorescent probe for copper (II). Microchim. Acta 183, 581–588 (2016).
Wang, C. et al. Dual-emitting quantum dot/carbon nanodot-based nanoprobe for selective and sensitive detection of Fe 3+ in cells. Analyst 141, 4488–4494 (2016).
Wang, Y. et al. In situ simultaneous monitoring of ATP and GTP using a graphene oxide nanosheet–based sensing platform in living cells. Nat. protoc. 9, 1944–1955 (2014).
Yan, B. Lanthanide-functionalized metal–organic framework hybrid systems to create multiple luminescent centers for chemical sensing. Acc. Chem. Res 50, 2789–2798 (2017).
Dey, N., Kumari, N. & Bhattacharya, S. FRET-based ‘ratiometric’ molecular switch for multiple ions with efficacy towards real-time sampling and logic gate applications. Tetrahedron 85, 132007 (2021).
Pundi, A. et al. A chiral carbazole based sensor for sequential “on-off-on” fluorescence detection of Fe3+ and tryptophan/histidine. Sens. Actuator B-Chem. 328, 129084 (2021).
Qiao, G. et al. Lanthanide molecular model triggers sequential sensing performance. J. Mol. Liq. 311, 113344 (2020).
Lin, L. et al. Ratiometric fluorescence detection of riboflavin based on fluorescence resonance energy transfer from nitrogen and phosphorus co-doped carbon dots to riboflavin. Anal. Bioanal. Chem. 411, 2803–2808 (2019).
Feng, S. et al. A ratiometric fluorescent sensor based on g-CNQDs@ Zn-MOF for the sensitive detection of riboflavin via FRET. Spectrochim. Acta A 246, 119004 (2021).
Wang, J. et al. Ratio-metric sensor to detect riboflavin via fluorescence resonance energy transfer with ultrahigh sensitivity. Phys. E 72, 17–24 (2015).
Wang, Y. et al. A dual-responsive and highly sensitive fluorescent probe for Cu2+ and pH based on a dansyl derivative. Dyes Pig. 180, 108513 (2020).
Yang, Y. et al. On-site, rapid and visual determination of Hg2+ and Cu2+ in red wine by ratiometric fluorescence sensor of metal-organic frameworks and CdTe QDs. Food Chem. 328, 127119 (2020).
Zhang, M. et al. A ratiometric fluorescent probe for sensitive, selective and reversible detection of copper (II) based on riboflavin-stabilized gold nanoclusters. Talanta 117, 399–404 (2013).
Nemati, F. et al. Fluorescence turn-on sensing of thiamine based on Arginine–functionalized graphene quantum dots (Arg-GQDs): Central composite design for process optimization. Sens. Actuator B-Chem. 255, 2078–2085 (2018).
Gong, F. et al. Polymer nanoparticles integrated with excited-state intramolecular proton transfer-fluorescent modules as sensors for the detection of vitamin B1. Microchem. J. 148, 767–773 (2019).
Dadkhah, S. et al. Rapid and sensitive fluorescence and smartphone dual-mode detection of dopamine based on nitrogen-boron co-doped carbon quantum dots. Microchim. Acta 187, 1–12 (2020).
Wang, Z.-X. et al. Aggregation-induced emission behavior of dual-NIR-emissive zinc-doped carbon nanosheets for ratiometric anthrax biomarker detection. ACS Appl. Bio Mater. 3, 9031–9042 (2020).
Wang, Z. et al. Ratiometric fluorescent sensors for sequential on-off-on determination of riboflavin, Ag+ and l-cysteine based on NPCl-doped carbon quantum dots. Anal. Chim. Acta 1144, 1–13 (2021).
Liu, X. et al. Nitrogen-doped carbon quantum dots from poly (ethyleneimine) for optical dual-mode determination of Cu2+ and l-cysteine and their logic gate operation. ACS Appl. Mater. Interfaces 12, 47245–47255 (2020).
Liu, C. et al. Photoinduced electron transfer mediated by coordination between carboxyl on carbon nanodots and Cu2+ quenching photoluminescence. J. Phys. Chem. C 122, 3662–3668 (2018).
Lin, L., Luo, Y., Tsai, P., Wang, J. & Chen, X. Metal ions doped carbon quantum dots: Synthesis, physicochemical properties and their applications. Trends Anal. Chem. 103, 87–101 (2018).
Xu, Q. et al. Highly fluorescent Zn-doped carbon dots as Fenton reaction-based bio-sensors: An integrative experimental–theoretical consideration. Nanoscale 8, 17919–17927 (2016).
Edwards, K. A. et al. Thiamine assays—advances, challenges and caveats. ChemistryOpen 6, 178–191 (2017).
Author information
Authors and Affiliations
Contributions
S.D. designed and perfumed the experiments and analyzed the data, and also write the manuscript. A.M. designed the experiments, interpreted the data and edit the manuscript. A.J. checked the data and manuscript. A.M. developed the smartphone application and has contribution in writing the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Dadkhah, S., Mehdinia, A., Jabbari, A. et al. Catalytic nanozyme Zn/Cl-doped carbon quantum dots as ratiometric fluorescent probe for sequential on-off-on detection of riboflavin, Cu2+ and thiamine. Sci Rep 12, 18276 (2022). https://doi.org/10.1038/s41598-022-23055-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-23055-6
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.