Introduction

There is a growing interest in studying deep venous thrombosis (DVT) in space since the first publications reporting on the coincidental detection of a thrombosis in the internal jugular vein (IJV) on board the International Space Station (ISS)1,2. The IJV thrombosis was reported as a possible consequence of venous congestion and blood flow anomalies in relation to fluid cephalad shifts, in addition to other venous thromboembolism (VTE) risk factors3.

Whilst DVT appears to be rare in space, it is a relevant issue because of its potential seriousness given it can affect cerebral drainage and/or cause pulmonary embolism, and because of the difficulty of remote diagnostic and therapeutic management. Such challenges are only going to increase as missions go beyond Low Earth Orbit (LEO) as the restrictions on mass, volume, re-supply and communications become more severe4. In addition, whilst at present astronauts are highly selected, commercial spaceflight will involve consideration of less stringent medical requirements5.

One of the main obstacles to the management of VTE in space is its diagnosis. Whilst ultrasound (US) is the preferred imaging modality both on the ISS and terrestrially, several questions remain unanswered regarding its use for the definitive diagnosis of DVT in space. The first is its validity and the risk of diagnostic error, particularly false positives, given the similarity of the thrombosis-related aspects with those induced by microgravity (i.e., venous congestion and flow stasis)6. The second is the actual extent and therefore the possible deep involvement e.g., at the level of the innominate venous trunk and the intra-thoracic veins. The third issue is the lack of studies on diagnostic accuracy and diagnostic management in patients with clinically suspected DVT in space. Therefore, the optimal venous ultrasound (V-US) criteria to rule-out and conversely rule-in the diagnosis of DVT in space remain to be defined, as is the case with clinical presentation including VTE risk factors7, and D-dimer and endothelial biomarkers8.

Given the lack of diagnostic studies, we sought to objectively and comprehensively explore how V-US was used and interpreted in spaceflight and thus conducted a systematic review of the studies reporting V-US in space to identify approaches in microgravity and compare them to terrestrial clinical best-practice V-US.

The objective of this review was to gather data to help inform practice, research, and guide recommendations for technical implementation of V-US in space to achieve an accurate diagnosis of DVT with better discrimination between DVT and microgravity-related congestion phenomenon in the upper body venous system.

This raised the following questions:

  • What are the changes related to microgravity, particularly those that may confound the diagnosis of DVT, to account for when performing V-US in spaceflight?

  • How to reverse microgravity-related changes and restore normal terrestrial conditions for optimal venous assessment in spaceflight?

  • How was V-US performed in spaceflight and to what extent was it appropriate for DVT detection in comparison with terrestrial V-US?

  • What are the implications for practice and research?

Methods

The methodological approach and reporting of the results followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines9,10 and the Space Biomedicine Systematic Review Methods (https://sites.google.com/view/sr-methods/guides)11. The protocol was registered in PROSPERO database (Registration number [CRD42023410886]).

Selection criteria

All four following criteria had to be met to include a publication for analysis in the systematic review: (1) the study had to have been carried-out in human participants, (2) in the setting of short or long-term spaceflights or acute exposure to microgravity, (3) using an US method including B-mode US, Doppler US, duplex US or Colour-Doppler US modality and (4) reporting any US assessment of the neck/ upper limb or lower limb venous systems (Table 1). Thus, studies on animals, human studies on ground-based spaceflight analogues, reviews, and duplicates (i.e., same record found in different databases) were excluded. The type of study whether observational (descriptive or comparative) or interventional was not a criterion for considering studies for this review. If a study was published more than once (multiple records), the earliest published article or the article combining cumulative results from different studies were included.

Table 1 Research question in PICOS Format.

Search methods for identification of studies

Following databases were systematically searched for relevant studies: PubMed (National Institutes of Health, National Library of Medicine), OVID versions of MEDLINE, Embase, Cochrane Library of Databases and EBM Reviews, since inception to July 24th, 2022. Google Scholar and databases maintained on NASA and ESA websites (https://www.nasa.gov/centres/hq/library/find/databases), were checked for pending or recently published full articles or conference presentations. Further searches included the reference lists of relevant articles and reviews, and citation index of journal websites and databases. The search also covered various sources of ‘grey literature’ (mainly conference abstracts and protocols) to identify published, unpublished, and ongoing studies. We also contacted study authors for unavailable (missing), incomplete or unclear study results.

There were no date or language restrictions on the searches. Languages other than English and French were translated from their original language to English by professional scientific translators.

The following Medical Subject Headings (MESH) and text words search terms were used:

  1. 1.

    “microgravity” OR “spaceflight” OR “hypogravity” OR “reduced gravity” OR “zero gravity” OR “weightlessness” OR “micro-G” OR “low gravity” OR “zero-G” OR “astronaut*” OR “cosmonaut”

  2. 2.

    “ultrasound*” OR “B mode” OR “echography” OR “sonograph*” OR “doppler”

  3. 3.

    “vein*” OR “venous*” OR “DVT” OR “VTE”.

These were then combined as shown in Table 2.

Table 2 Search method.

Selection of studies

After having removed duplicates, potentially eligible studies were identified by examining titles and abstracts, with full articles acquired when appropriate. Study assessment was performed by two independent and blinded reviewers to avoid selection bias. Disagreements were all resolved through discussion between the assessors.

Data extraction

First, data was extracted from selected studies regarding study characteristics: author, year of publication, participating centres, time-period when study was conducted, study duration, objective, design, population, outcome measures, analysis issues and summary of findings.

Second, data was extracted about V-US changes in-flight for the neck/ upper limb venous system, to establish a baseline for the diagnostic exclusion of DVT and prevent DVT overdiagnosis and overtreatment, with a special focus on DVT screening studies. Data was also extracted about the type and the effect of venous interventions on such changes, including lower body negative pressure (LBNP) at different negative pressure levels, thigh-cuffs (Bracelets or “Braslets”), respiratory manoeuvres (Valsalva and Mueller manoeuvres), and contralateral IJV compression.

Finally, to assess appropriateness of spaceflight V-US with terrestrial V-US standards, we performed a review regarding methods and performances of V-US in diagnostic accuracy and diagnostic management studies conducted on Earth in patients with clinically suspected upper extremity deep vein thrombosis (see methods in Supplementary Materials). A bias assessment tool based on terrestrial V-US standards was developed following discussions with a group of experts in space medicine, vascular medicine, venous thrombosis, and vascular ultrasound. The tool included appropriateness criteria for an optimal V-US relevant to:

  1. 1.

    crew experience: individuals who performed and interpreted the V-US (expert physician or sonographer astronaut or non-expert, use of remote control or remote guidance, personnel training, image captures, annotation procedures and V-US interpretation),

  2. 2.

    in-flight equipment: the types of equipment used for V-US assessment (US device/ scanner, probe emission frequency for peripheral and central vein studies, US modalities),

  3. 3.

    assessment sites: the sites examined for V-US assessment (right side, left side or both, vein segments and US views, for neck/ upper limb venous systems).

  4. 4.

    US methods: the US diagnostic methods used (B-mode, Colour-Doppler, Duplex US, …) for the assessment of the neck/ upper limb system, and

  5. 5.

    DVT diagnosis: the diagnostic criteria used for DVT screening if any.

For each type of data collected on V-US characteristics in spaceflight studies, we attempted to capture when in-flight V-US was comparable to terrestrial state-of-the-art clinical practice and when it was not.

Data (Supplementary Table 1) was collected using standardised forms on Excel sheet.

Data analysis and synthesis

Our objective was to perform a descriptive analysis of study characteristics and V-US assessment characteristics, and to provide a summary of findings regarding in-flight changes, effect of venous interventions on these changes, and V-US assessment characteristics with a special focus on studies reporting on DVT diagnosis.

We did not report a quantitative synthesis of the changes and the effects of interventions as this was not the primary objective and because of an important heterogeneity between studies.

Reporting summary

Further information on research design is available in the Nature Research Reporting Summary linked to this article.

Results

Search results

Figure 1 shows the flow of studies through the review following PRISMA 2020 updated guideline10.

Fig. 1: Search strategy based on PRISMA 2020 flow diagram10.
figure 1

Records were identified from databases and other sources, then screened and assessed for eligibility.

Based on our search criterion through electronic databases (Supplementary Tables 25): 165 records were obtained in PubMed, 66 in MEDLINE, 96 in Embase and 2 in Cochrane and EBM reviews yielding a total of 329 records Many records were duplicates (n = 138), were not eligible (n = 174) with all three eligibility criteria being unmet (n = 94), two of them unmet (n = 25), or only one unmet (n = 49) and other reasons (n = 6) such as records published in forms of abstract (n = 1), review (n = 2), reply/ comments (n = 1) and multiple records (n = 2). Thus, finally, 17 full text records were sought for retrieval and assessed for eligibility of which two were excluded (one a method description about remote echography12 and the other a review paper13), but 15 were retained1,2,14,15,16,17,18,19,20,21,22,23,24,25,26.

Six other studies were identified via the other sources provided in “Search methods” section of which two were retrieved and assessed for eligibility. One was excluded because it did not use the ultrasound as assessment method27 but the other one was retained28.

Therefore, 16 studies in total were included in present analysis.

Characteristics of included studies

Included studies were published between 1994 and 2022. Two reported on acute exposure to microgravity and hypogravity during parabolic flight campaigns23,24, one on short-term28 and ten on long-term (≥6 months) chronic exposure2,14,15,16,18,19,21,22,25,26; In three other studies the class of exposure duration was not reported1,17,20. Only three studies involved DVT detection1,2,25 of which one reported exclusively on DVT1 (Table 3).

Table 3 Characteristics of included studies.

Studies reported data on between 1 to 14 crewmembers. Most studies used repeated measurements and compared inflight with pre-flight and postflight measurements, and long-term with short-term inflight outcomes. The main measure assessed was the cross-sectional area (CSA) of the IJV, rarely the femoral vein. The other types of evaluation included Doppler flow patterns, echogenicity, peak velocity, vein pressure and IJV pulse, performed in some studies with, and without venous interventions (Table 3).

Methodological quality of included studies

There was a substantial variability between studies in year of publication, study design, objectives, outcomes, V-US method, quality, statistical analyses, and reporting. Reporting issues were found mainly in older studies. Between-study heterogeneity prevented from performing meta-analysis.

V-US changes induced by microgravity in spaceflight studies

The purpose was to identify changes induced by microgravity in the upper body venous system to account for when carrying out explorations in spaceflight. Of the 16 spaceflight studies included, 13 focused solely on microgravity-related changes14,15,16,17,18,19,20,21,22,23,24,26,28, one exclusively on DVT detection1, and two studies on both microgravity-related changes and DVT detection2,25. Most studies reported inflight V-US changes in contrast with terrestrial findings (pre-flight mainly) at the level of the IJVs, rarely the femoral veins. Most changes were reported as an increase in IJV (and femoral vein) CSA and volume, and in IJV pressure, associated to a decreased blood flow velocity, increased blood echogenicity most frequently seen in the left IJV, and slow, retrograde left IJV blood flow. Results of left IJV investigation reported were different and need be analysed separately from those obtained at the right IJV (Supplementary Table 6). A summary of the reported findings is displayed in Table 4.

Table 4 Summary of in-flight venous ultrasound changes.

Reversal of V-US changes with venous interventions in-flight

The objective was to identify in case of venous congestion in the IJV what type of intervention was able to reverse the effect of microgravity and restore optimal conditions (i.e., normal terrestrial venous morphological and haemodynamic aspects (1 G supine)) in-flight (Table 5 and Supplementary Table 7), thus determining that venous congestion was likely related to microgravity and not to DVT. Among 16 included studies, 10 reported on such interventions. All used quantitative data analyses with continuous variables. None have reported results as categorical data that could help analyse the sensitivity of V-US to changes induced by each intervention.

Table 5 Summary of the effect of in-flight venous interventions.

LBNP

The application of LBNP at −25 mmHg for 30 min was able to restore variables at least back to pre-flight supine levels and reduced the associated flow and tissue disturbances16. The calf volume increased as the LBNP negative pressure decreased (−25 mmHg and −45 mmHg of 10 min with a transition step of −35 mmHg)28. There was less increase in calf circumference at LBNP −45 mmHg21. This was associated with a reduction of CSA and an improvement of blood flow in the IJV. The IJV volume returns to pre-flight supine level in 10/ 12 astronauts (83%) from our analysis of reported figure16.

Cuffs (Bracelets)

With versus without cuffs, IJV area decreased, and femoral vein area increased19,20,21. Cephalic congestion was reduced without a noticeable effect on cerebral blood flow19. As cited by Arbeille15, a 30 mmHg thigh-cuff pressure positioned at the upper part of the thigh traps blood and other fluids in the superficial leg veins and tissues, and consequently, reduces the IJV area in-flight, restoring it to pre-flight or pre-bed rest levels21,29.

Respiratory manoeuvres

An increase in femoral vein area was found with the Valsalva manoeuvre, with a little additional increase when adding Valsalva manoeuvre to bracelets as compared to bracelets alone20. Internal jugular vein area decreased with bracelets, with the Mueller manoeuvre and with the combination of both bracelets + Mueller manoeuvre20. Venous flow was found to be induced by the Mueller manoeuvre1. A modified Mueller manoeuvre increased peak venous flow velocity and reduced echogenicity25. In two individuals with retrograde blood flow, both the modified Mueller manoeuvre and the contralateral manual compression of the right IJV reversed flow direction to antegrade while the manoeuvre was performed25.

In total, venous interventions were on average effective in reducing or even normalising in-flight changes (Table 2 and Supplementary Table 9). Limited data was available on individually induced effect of interventions.

Appropriateness of spaceflight ultrasound for venous assessment and DVT detection

The objective was to capture and highlight the gaps and technical issues associated with performing spaceflight V-US of the neck/ upper limb venous system in comparison with optimal methods on Earth.

Systematic reviews of diagnostic accuracy studies30,31,32 and diagnostic management33 studies in patients with clinically suspected upper extremity DVT on Earth were reviewed. They show a high diagnostic performance of V-US testing. In the systematic review of Patel et al.32, the pooled estimates for duplex US sensitivity and specificity from 7 studies34,35,36,37,38,39,40 were 87% (95% CI, 73–94) and 85% (95% CI, 72–93), respectively32. The diagnostic performance seems lower than it should actually be due to the inclusion of screening of asymptomatic catheter-induced subclavian vein thrombosis studies in the meta-analysis38. Sensitivity is lower in the screening setting as the thrombus is usually small and non-occlusive41. In a single-centre prospective diagnostic management study, among 337 symptomatic outpatients in whom the diagnosis of upper extremity DVT was ruled-out by colour-Doppler ultrasound and anticoagulant treatment was withheld, only one patient presented a DVT event during a 3-month follow-up resulting in a failure rate of 0.30% (95% CI, 0.05–1.68%)33. A normal upper extremity V-US finding based on duplex ultrasound (with or without colour Doppler ultrasound) can safely exclude DVT.

As stated above, appropriateness criteria for an optimal V-US testing on Earth were set-up after review of studies and expert panel discussions (Table 6), as follows:

  1. 1.

    For crew performing the V-US to be comparable to terrestrial environments, the study should have included a qualified physician astronaut or sonographer on board, or an astronaut with ground-based manual remote control (i.e., tele-operated echograph and motorised probe), both with a specialised interpretation/ analysis of US images. Crew was considered not comparable to terrestrial one if there was only ground-based remote guidance (by voice), even if the astronaut was adequately trained in positioning the probe and capturing images and if the US images were subject to specialist interpretation/analysis. The ©2021 and ©2023 IAC (Intersocietal Accreditation Commission) Standards and Guidelines for Vascular Testing Accreditation (Published November 15, 2021, and June 1, 2023) consider training and experience in venous duplex ultrasound adequate for established practice for a physician who has worked in a vascular facility for at least the past three years and has interpreted 300 diagnostic cases. In comparison, the astronauts have before their flight a familiarisation session (approx. 3 h). The appropriate V-US method for “upper extremity” DVT screening in space is more complex than V-US limited to the IJV or the lower-limb peripheral veins and requires much more extensive training/ expertise. Although limited compression ultrasound of peripheral veins can be performed accurately by an operator with little training as shown in terrestrial studies in symptomatic patients42,43, there is a significant heterogeneity between studies in terms of the degree of training required44. The context of UEDVT screening during spaceflight is different as astronauts are asymptomatic and therefore the thrombus may be small and non-occlusive45,46, and the location may concern isolated central (i.e., “intrathoracic”) or deep IJV as in the reported thrombosis case1,2. Remote (manual) control has many advantages12,47. It allows full control of the probe orientation by the expert and provides diagnoses in 97% of cases48. Remote guidance is highly dependent not only on remote guider expertise and instructions but also on individual operator skill to self-scan and prevent errors from probe/hand movement. Remote guidance is sufficient for superficial vessel examinations but not suited for deep or superficial organs48. A recent publication using 3D scan on same structure found more consistent results with the motorised probe compared with remote guidance49.

  2. 2.

    For in-flight ultrasound equipment to be appropriate and optimal for venous assessment and be comparable to terrestrial standards, it should have included equipment with high resolution imaging devices/ scanners, various ultrasound emission frequencies in B-mode (e.g., L12-5 MHz for peripheral veins, P5-2 MHz for intrathoracic veins) and adequate transducer sizes (small transducers for central veins) integrating different US modalities (B-mode + colour-flow + doppler ultrasound). Otherwise, in-flight equipment was considered to have limitations and to be inappropriate for an optimal V-US assessment.

  3. 3.

    For in-flight assessment sites to be comparable to terrestrial ones, both peripheral deep and superficial veins of the arm, the axilla, and the neck, and central (i.e., intrathoracic) veins should have been examined for DVT detection and thus assessment should have included not only jugular veins but also other peripheral and accessible intrathoracic veins of the neck/ upper limb system (subclavian vein and innominate trunk). This criterion was applicable only to studies involving DVT detection.

  4. 4.

    For in-flight V-US assessment method to be comparable to terrestrial one, it should have included both morphological and hemodynamic assessment modalities. The high performance of V-US examination in terrestrial studies has been achieved by combining B-mode ultrasound and Doppler (i.e., colour Doppler ultrasound, duplex ultrasound). Because central veins cannot be systematically and adequately examined due to the presence of overlying bones, imaging and doppler patterns analyses should be combined. This criterion was applicable only to studies involving DVT detection.

  5. 5.

    For V-US DVT detection criteria in-flight to be comparable to terrestrial one, the diagnosis should have relied on the direct visualisation of the thrombus on B-mode or colour-Doppler ultrasound and on vein incompressibility (only for peripheral veins), and abnormal flow patterns within or distal to the thrombosis on duplex ultrasound. The combination of direct and indirect identification of vein thrombosis is essential. Indirect investigation of the central veins based on the Doppler signal50 is a key element for the diagnosis exclusion of central (intrathoracic) DVT when it shows normal phasicity with respiration and cardiac cycle at the level of the axillary vein (or subclavian and brachiocephalic veins) in supine position32,51,52. Loss of phasicity is diagnostic of central vein obstruction32,51,52 in the absence of extrinsic compression. When several parameters are evaluated in combination (thrombus visualisation, absence of spontaneous flow, absence of phasicity with respiration/ cardiac cycle, vein incompressibility), venous ultrasound is a reliable method for DVT detection30,39,53.

Table 6 Appropriateness criteria and comparison of inflight venous ultrasound with terrestrial standards.

Studies in space can be divided into DVT and non-DVT studies. In DVT studies1,2,25, one case of ultrasound-detected DVT was reported in two separate papers in an asymptomatic astronaut with description of vascular aspects at diagnosis1,2 and follow-up1. A second case was reported based on retrospective analysis of ultrasound images in another asymptomatic astronaut and adjudicated as a “likely” DVT2. In another study intending to screen for DVT, all astronauts (n = 11) remained asymptomatic and no DVT was detected by US25. All three studies assessed morphological and flow patterns with, and without venous interventions1,2,25.

Tables 6 and 7 summarise appropriateness of spaceflight V-US with terrestrial V-US standards relevant to the crew performing V-US, equipment, assessment sites, assessment methods, and DVT detection criteria as follows:

  1. 1.

    For crew performing V-US: In-flight V-US was performed by expert on board physician astronaut or sonographer in four publications (Tables 6 and 7). None of these was involving DVT screening. Indeed, in the two DVT publications reporting on the same thrombosis case1,2, there was a physician astronaut on board likely familiar with vascular ultrasound but her/ his extent of training and expertise in V-US for UEDVT screening is unknown. No publication reported V-US performed under ground-based remote manual control, four publications including a third DVT study25 reported V-US performed under remote verbal guidance, and there was a reporting issue regarding the crew in six other publications. Overall, crew performing in-flight US was only in four publications18,19,23,24 comparable to the terrestrial clinical standard (Tables 6 and 7 and Supplementary Table 8).

  2. 2.

    For V-US equipment: In the three DVT studies, the emission frequency was too high and the probe too large (linear) to enable investigating IJV deep segment, subclavian and intrathoracic veins which may bias the V-US results. In the other studies, V-US equipment was appropriate and adapted to the study objective (Tables 6 and 7 and Supplementary Table 9).

  3. 3.

    For V-US assessment sites: Assessment of upper extremity venous system was limited to the IJV according to the objective of the studies. In DVT studies, the other peripheral veins and intrathoracic veins were not directly evaluated as in terrestrial DVT screening on Earth (Tables 6 and 7 and Supplementary Table 10).

  4. 4.

    For V-US assessment methods: In the DVT studies, V-US methodology was comparable to terrestrial standards as morphological and hemodynamic assessments were combined. In the other studies, V-US methodology was adapted to the purpose of the study, mainly the assessment of cephalad congestion on B-mode US (dilation, increased echogenicity, increased vein pressure) and Doppler flow characteristics (magnitude, direction, aspects, phasicity) (Tables 6 and 7 and Supplementary Table 11).

  5. 5.

    For DVT diagnostic criteria : The diagnosed left IJV thrombus reported in two separate papers1,2 was described as echogenic and occlusive with the vein almost compressible and associated with stasis (spontaneous echo-contrast), absence of flow and flow reversal. Images of thinned thrombus was obtained on follow-up V-US during spaceflight. Venous flow returned to normal upon landing on Earth. As the diagnostic issue was in the deep proximal segment of IJV where compression US test is difficult to acquire, the diagnosis was based not only on the absence of venous flow which may be due to congestion phenomenon as well, but on its combination with the direct image of the thrombus. Unfortunately, no video recordings were available to enable discriminating between a stasis image and a true direct thrombus image. The quality of the reported IJV thrombus image although acquired with a L12-5 MHz probe on oblique sagittal planes is not sufficient to indicate a thrombosis within the images of stasis. No comparative diameter (or volume) measurements were performed on follow-up to attest of the potential thrombus evolution. The reported thrombus consistency pattern may depend on V-US compression force, and the volume reduction estimate on probe positioning. LBNP in-flight and HDT postflight countermeasures were not performed for this astronaut. The increase in flow following the Mueller manoeuvre54,55 and the absence of altered flow patterns post-flight are more suggestive of microgravity-related stasis (Tables 6 and 7). The second DVT case following a retrospective analysis of ultrasound images from astronauts was reported as a “potential thrombosis” and was described as a partial IJV thrombus2. In the surveillance DVT study25, a bilateral IJV screening was performed and assessed morphological and flow patterns in 11 astronauts. Despite the absence of any thrombosis, vein congestion and abnormal flow characteristics (such as reduced peak velocity, “mild–moderate” echogenicity in six participants, and retrograde blood flow in two participants) were observed and were prominent in the left IJV25. This suggests a lack of specificity of venous congestion and abnormal flow patterns criteria in DVT screening during spaceflight and the need of venous interventions to restore normal diameter and flow patterns as was done in this study25.

Table 7 Bias assessment in spaceflight venous ultrasound in comparison with terrestrial standards.

In total, in the DVT studies (n = 3), only the V-US assessment modality criterion was fully appropriate. Crew performing V-US, used equipment, measurement sites and DVT diagnosis criteria were not entirely comparable to optimal terrestrial clinical practice. In the other studies (n = 15), all criteria (equipment, measurement sites and US modalities) were appropriate for the study objective except the crew experience criterion, which was appropriate in only four studies.

Discussion

To the best of our knowledge, this is the first review investigating knowledge gaps between spaceflight and on-Earth V-US assessment. Results are summarised and shown in Fig. 2. Two types of barriers to optimal V-US evaluation were identified. They were either related to changes induced by microgravity or related to testing. Taking these results into account will help to make the necessary changes in the practice of V-US exploration in spaceflight and improve its diagnostic performance for the detection of DVT in the upper body venous system.

Fig. 2: Summary of study results in spaceflight.
figure 2

Context, methods and findings regarding microgravity-related changes and effect of venous interventions to reverse them, and appropriateness of spaceflight venous ultrasound with terrestrial standards.

A systematic review combining spaceflight and ground-based analogue data on the effect of microgravity on the human venous system3 reported similar findings/ changes related to cephalad venous congestion with increased vein dilation and venous pressures and decreased/ reversed flow in microgravity. Previously published studies and reviews56,57,58 about interventions have assessed the role of in-flight interventions to prevent pathological and vascular changes but not as tools to improve diagnostic performance as in our review.

This review was restricted to spaceflight and did not include ground-based analogue studies. On the ground, V-US assessment is performed by highly specialised experts as opposed to in-flight V-US assessment performed by rather inexperienced crewmembers. According to Arbeille et al.14, IJV size changes differ between HDT and spaceflight probably due to differences between the intensity of the forces causing the fluid shift, and overall differences in mechanisms between the two conditions17.

A risk of publication bias cannot be excluded. The Cochrane handbook recognises that it is possible studies may be missing from a review59. As stated in the methods section, we relied upon a comprehensive search strategy to ensure that as many relevant studies are included as possible by searching grey literature, by including all studies regardless of their publication language (four studies published in Cyrillic were translated by professional scientific translators into English), and by contacting authors.

There is a risk of major reliability issues (repeatability and replicability of results) within studies in relation to the measurements of venous CSA and volume, Doppler flow characteristics and venous pressure. These measurements are not entirely precise even on Earth and when performed by experienced sonographers because of potential variability of explored venous segment, and variability of vein diameter and Doppler signal during cardiac cycle and respiration (and posture on Earth). As for venous pressure, it depends on the adequate and exact amount of compression needed to collapse the vein by the operator.

Conduct, analysis and reporting of methods and study results revealed significant shortcomings that must be addressed in future in-flight DVT studies. Reporting issues were related to the conduct of V-US (staff, training, remote control, annotation procedure, image captures, interpretation), the equipment used (Supplementary Table 9), V-US findings (Supplementary Table 6), assessment sites (Supplementary Table 10) and V-US methods (Supplementary Table 11). Most of the studies have included small sample sizes that may have biased the results. The sample size of spaceflight research is often small due to the time and financial cost of training astronauts60,61.

Our review has some limitations. Our data synthesis is only qualitative. Between-study heterogeneity and potential lack of reliability of measurements prevented from performing a quantitative synthesis (which was not in the scope of the objective). Extreme levels of heterogeneity in the use of outcome measures and a lack of study replication prevent the implementation of gold-standard meta-analysis techniques62. This, in addition to methodological issues within the included studies (lack of consistency in data collection within repeated measures studies63,64, lack of controlled trials), would have resulted in a lack of accuracy of measurements in our review and prevented us from any further quantitative assessment. Overall, the lack of quantitative synthesis should not have an impact on our objective. It was not possible to assess clinical probability due to the very small number of patients assessed and cases of venous thrombosis reported, and simply because patients were asymptomatic. In the context of spaceflight, clinical prediction rules need to be developed and validated considering the symptoms and signs related to the congestion phenomenon and based on a valid diagnostic outcome before they can be proposed and used in practice.

There are several implications for practice during spaceflight:

  1. 1.

    The present study revealed that current ultrasound screening tests for DVT in-flight need further development. It is essential to account for the various possible biases encountered in the present review when performing V-US in space.

  2. 2.

    Venous Ultrasound assessment “requires a great deal of training to perform ultrasound examinations, which can be difficult and time consuming, especially if the astronaut does not have a medical background”12. The aim of the studies carried out during spaceflights was to assess changes associated with microgravity and not to screen for DVT. Reported IJV thrombosis in spaceflight was unexpected, and astronaut were not familiarised with this type of testing. Assessing microgravity-related changes necessitated the use of sections mostly limited to the IJV. The search for “upper extremity” DVT in space is exposed to much greater technical difficulties, not so much for the assessment of peripheral veins where the analogy with the veins of the lower limbs is possible with interesting results and little training42,43,44, but above all for the exploration of central/“intrathoracic” veins (i.e., deep proximal IJV, subclavian vein, brachiocephalic vein, etc.). Exploration is no longer carried out at 2 or 3 points or based on the compression test but based on the sonographer’s ability to perform a complete assessment of the entire venous network, both directly (i.e., morphologically) with B-mode and colour doppler US and indirectly (i.e., haemodynamically) by analysing blood flow with duplex US. Two additional difficulties can be added to V-US assessment in space: the likely predominance of isolated anomalies in central veins and the challenge to distinguish the thrombus image from the very common stasis image, hence the importance of using dynamic manoeuvres to eliminate the stasis effect.

  3. 3.

    Because astronaut training is not sufficient to reduce the lack of reliability of V-US assessment, it is essential to adopt different training standards and to shift to the use of other systems such as tele-operated US systems12 with motorised probes (or maybe farther in the future, AI-based systems or systems using augmented reality).

  4. 4.

    It is important to be aware of the risk of over-diagnosis of DVT in the upper body venous system in space. A comprehensive investigation of the whole venous network (peripheral and central veins) is essential to identify an image of a real thrombosis and to clearly distinguish thrombosis from venous congestion. The use of venous interventions during spaceflights may be helpful to re-establish terrestrial conditions for a better V-US assessment.

There are also many implications for research and medical space operations:

  1. 1.

    Our results will provide a useful roadmap of desired diagnostic ultrasound methods and criteria that could be assessed and validated in future studies allowing set up of space-dedicated diagnostic algorithms facilitating decision-making. Moreover, the present results may help in designing studies on crew training and standardised image interpretation criteria. However, unexpected findings might occur with higher probability during a thorough research protocol.

  2. 2.

    In spaceflight, the diagnostic accuracy of terrestrial US criteria is unknown. Slow, stagnant, retrograde blood flow, especially in the IJV, due to volume overload and elevated venous pressures secondary to the classic cephalic fluid shift8,56,65, may mimic the aspects encountered in venous thrombosis. It is important to improve V-US scanning conditions by decreasing central venous pressure and venous congestion through the effect of venous interventions such as thigh cuffs, LBNP, Mueller manoeuvres and contralateral IJV compression. This could restore a venous flow with normal respiratory and cardiac phasicity useful for the investigation of intrathoracic veins, and restore a normal vein size that could facilitate the compressibility of a thrombosis-free peripheral vein segment and thus improve diagnostic specificity in-flight. This needs to be addressed in a study with adequate sample size that could assess the ability of interventions (and their intensity levels) on restoring normal blood flow and normal vein sizes to facilitate US-based DVT screening.

  3. 3.

    More effort needs to be put into developing new diagnostic technologies and maturing emerging terrestrial technologies for use in space to individualise thrombosis direct image at the level of the peripheral veins and the central veins. Equipment should be adapted to the context of missions beyond ISS. Ultrasound equipment for Artemis mission (hardware, motorised probe), not yet selected, will be by necessity a hand-held unit. It is not impossible for a hand-held unit to have many (or all?) of the functionality of the laptop-sized units that are currently on ISS. Time lags during sessions will increase as we move beyond ISS. It is remote guiding, not robotic probe operation, that will break first. Increasing the up-commanding lags does not necessarily prevent operation of the robotic probe.

  4. 4.

    Finally, it is highly important to set-up reporting methods specifically tailored for studies performed in space.

This systematic review shows that spaceflight V-US studies carried out to date are not of sufficient quality to assess for DVT, due to microgravity-related changes and testing methodology used. Findings from this systematic review will help inform practice and research towards optimal conditions of use adapted to a spaceflight situation. Future studies should adopt Earth-based ultrasound practice and evaluate the individual effect of interventions on V-US morphological and hemodynamic changes.