There is an Editorial associated with this article: 10.1038/npjpcrm.2014.13.

Introduction

Asthma is a chronic airway disease characterised by airway inflammation, bronchoconstriction and increased airway responsiveness.13 Inhaled corticosteroids (ICS) control chronic inflammation and produce significant increases in morning and evening peak expiratory flows.4 ICS may be used as the first choice in controlling mild to moderate asthma and usually exhibits a good response.

Ciclesonide (CIC) itself lacks appreciable activity and can be considered a prodrug.57 On inhalation, CIC is converted in the lungs by endogenous esterases to its active metabolite, desisobutyryl-CIC (des-CIC), which has a high receptor affinity and forms reversible conjugates with lipids within the lung.8 Moreover, CIC possesses other favourable pharmacokinetic–pharmacodynamic properties, such as a reported systemic bioavailability of <1%.912 The CIC is formulated in hydrofluoroalkane solutions, which can be deposited >50% into the lower airways and distributed substantially to the small airways,13 with only minimum deposition in the oropharynx area.14 Another advantage of small-particle ICS is that it reaches the small airways and alveoli15 and consequently results in anti-inflammation, including decreased levels of alveolar and bronchial exhaled nitric oxide7,16 and attenuated infammatory markers in the exhaled breath condensate.16

Asthma management guidelines recommend a step-down strategy when asthma has been well controlled after an initial treatment of 3 months.17 A recent systematic review with a meta-analysis stated that discontinuing long-acting β2-agonist (LABA) therapy in adults and older children with asthma controlled with a combination of ICS and LABAs results in increased asthma-associated impairment.18 On the other hand, there are concerns over the safety of LABAs that has led to the recommendation by the US Food and Drug Administration that LABA be discontinued once asthma is controlled by combination therapy and that treatment with ICS alone should be the long-term treatment for asthma control.19 In the sysytematic review by Brozek et al.,18 the studies reviewed maintained their patients on either budesonide (BUD) or fluticasone inhaler alone after the LABA component was discontinued.

This study posits that the use of a new formulated CIC could provide better control of asthma during LABA step-down therapy. In our study, patients stepped down from combination therapy to mono-ICS with the same dosage of ICS. However, until now, no comparison assessing the efficacy of step-down therapy from ICS and LABA combination to ICS only by using inhaled CIC alone in patients with asthma has been studied. Thus, in this study, we assessed and compared the efficacy and drug adherence of once-daily CIC at 320 μg with twice-daily BUD at 400 μg in treating mild to moderate asthma patients after step-down therapy.

Materials and Methods

Study design

This was a multicentre, open-label, randomised, parallel-controlled study evaluating the efficacy of 320 μg Alvesco QD (Nycomed GmbH, Konstanz, Germany) with 400 μg Duasma (Boehringer Ingelheim KG, Ingelheim, Germany) BID in patients with mild to moderate asthma after step-down therapy. The trial took place from April 2009 to June 2010. The inclusion criteria were as follows: male or female outpatients; nonsmokers; ex-smokers with a smoking history of <10 packs per year; age 16 years; and a documented clinical history of reversible airway obstruction with an increase in forced expiratory volume in 1 s (FEV1) of 12% and more than 200 ml, obtained 15 min after inhalation of salbutamol (400 μg).20 Patients were well controlled (asthma control test (ACT) score 21) and regularly used combination therapy at a dose of Symbicort (AstraZeneca, Södertälje, Sweden) (formoterol 4.5 μg+BUD 160 μg) 2 puffs twice daily or Seretide (GlaxoSmithKline, Brentford, UK) (salmeterol 50 μg+fluticasone propionate 250 μg) 1 puff twice daily for at least 3 months before entry. Exclusion criteria were as follows: current smokers or smoking history of >10 packs per year; a lower respiratory tract infection within the last 4 weeks; taking oral or parenteral corticosteroids for at least 4 weeks prior to Visit 1; or recent acute exacerbations of asthma or uncontrolled disease. The study protocol was approved by the Institutional Review Board of Chang Gung Memorial Hospital (IRB No. 97-2157A3). Written informed consent was obtained from all patients.

During the 1-week run-in period, eligible patients received only the equivalent dose of ICSs (either BUD or fluticasone) with step-off LABAs, and salbutamol was used as a rescue medicine. After the run-in period, all patients who satisfied the entry criteria discontinued their usual inhaled medicine and replaced it with the study medication while continuing to use inhaled salbutamol as a rescue medicine. As the lung distribution of ICS formulated in a metered-dose inhaler is less than that of hydrofluoroalkane,13 the equivalent corcosteroid dose of BUD was applied as twice that of ciclesonide in this study. Eligible patients were randomised to receive either CIC (160 μg) at 2 puffs once daily or BUD (200 μg) at 2 puffs twice daily (Figure 1). At the end of the 12-week treatment period, patients stopped the study medication and appropriate asthma medication was then prescribed by the investigator.

Figure 1
figure 1

Study design.

Patient population

Of the 162 patients with asthma who were approached, 8 refused and 4 failed the initial screening during enrolment (Figure 2a). Figure 2 gives an overview of the patient disposition. Four (22.2%) in the CIC group and 19 (65.0%) in the BUD group (P=0.007) did not complete the treatment because of poor control of asthma (Figure 2a), manifesting as daytime symptoms more than twice a week, nocturnal attacks or waking, need for rescue medicine more than twice a week, or limitation of daily activities because of asthmatic symptoms.

Figure 2
figure 2

(a) Flowchart of patient disposition. Withdrawal due to poor control of asthma involved 64.5% of patients in the budesonide group but only 22.2% of patients in the ciclesonide group. (b) Percentage of patient adherence to the study after 4, 8 and 12 weeks of treatment in the ciclesonide and budesonide groups. The percentage of adherence to the study was significantly decreased in the budesonide group compared with the ciclesonide group until the end of the study. The P value was calculated by means of the log-rank (Mantel–Cox) test.

Primary and secondary objectives

To compare the effectiveness of CIC with BUD in treating asthmatic patients, the primary efficacy variable was the improvement in FEV1 at the end of the treatment period (12 weeks). Secondary efficacy included the measurements of forced vital capacity (FVC) and maximum mid-expiratory flow (MMEF) through the treatment period. Secondary asthma control variables included the ACT score, adherence to the study, and measurements of satisfaction rating by patients and physicians of CIC (160 μg) at 2 puffs once daily compared with BUD (200 μg) at 2 puffs twice daily in asthmatic patients.

Pulmonary function test

At Visits 1, 2, 3, 4 and 5, the highest of the three technically acceptable measurements of FEV1 were recorded. The FVC, FEV1 and MMEF measurements were recorded using the same spirometer throughout the study, and were taken in the morning, usually 12 h after the last dose of the study medication, and at the same time on each visit day.

Asthma control test

The ACT was a patient-completed questionnaire that evaluated the following five items in the preceding weeks: limitation of activities; shortness of breath; awakenings at night; use of reliever medication; and patient’s perception of asthma control.21,22 Each question had five response options, resulting in a score range of 1–5. The sum of all scores yields the total ACT score, ranging from 5 (poor asthma control) to 25 (optimal asthma control). The ACT test has been validated in patients aged 12 years and older. Patients were given an ACT to complete on visits 2, 4 and 5. The investigator explains the test to the patients, which enables the patients to complete the ACT by noting down the responses for each item on a scale of 1–5.

Patients’ satisfaction rating and physicians’ assessment

At the end of the treatment, patients were asked to rate their overall satisfaction (very satisfied, satisfied, neutral, dissatisfied, very dissatisfied) with the trial medication in managing asthma. The physicians’ assessment was also recorded to obtain their overall satisfaction rating (very satisfied, satisfied, neutral, dissatisfied, very dissatisfied).

Statistical analysis

Data were expressed as mean±s.d. The demographic details were summarised with descriptive statistics. We used Prism 5 software (GraphPad Software, La Jolla, CA, USA) for data analysis. Fisher’s exact test (qualitative data) or analysis of variance (quantitative data) was employed to test the homogeneity of the treatment groups. As the data of treatment groups were multiple repeated measurements, generalised estimating equations (GEE) were applied to analyse the difference between treatment groups at each time point using SPSS v20 software (IBM, Armonk, NY, USA). Patient adherence to study was constructed by the Kaplan–Meier method and the curves were compared using the log rank test. A P value<0.05 was considered significant.

Results

Patient characteristics

A total of 150 patients (48.7% females) aged 19–75 years (mean, 53.4 years) were randomised to the CIC group (n=75) and the BUD group (n=75). Table 1 summarises the baseline characteristics of all patients who were enrolled into the study on Visit 2. There was no significant difference in gender, age, body height, BMI, smoking status, ACT score and lung function between the two patient groups (Table 1). There were no significant changes in lung function test and ACT score between Visit 1 and Visit 2.

Table 1 Patient demographics and baseline characteristics

Adherence to the study

Patients in the CIC group had a higher rate of treatment adherence (57/75, 76%) than those in the BUD group (44/75, 59%, P=0.03) (Figure 2b). In all nonadherent patients, 20 of 31 (65%) in the BUD group and 4 of 18 (22%) in the CIC group withdrew from the study because of poor control of asthma (P=0.007) (Figure 2a). As a whole, 27% of patients in the BUD group and 5% in the CIC group withdrew from the step-down therapy because of poor control of asthma (P=0.002).

Pulmonary function tests

Patients in the CIC group maintained a stable FVC throughout the 12-week treatment, whereas that of patients receiving BUD decreased after 4 weeks of treatment (2.8 l, 95% confidence interval (CI), 2.5–3.0 l, n=65) compared with baseline (2.9 l, 95% CI, 2.7–3.1, n=75) (Figure 3a). However, there was no significant difference between the two groups throughout the 12 weeks of treatment. The FEV1 in the CIC group remained stable throughout the treatment period (Figure 3b). The FEV1 (before bronchodilators) of the CIC group (2.2 l, 95% CI, 2.0–2.4 lL, n=72) was significantly higher than that of the BUD group (1.9 l, 95% CI, 1.7–2.1 l, n=65, P=0.02, Figure 3b) at 4 weeks and at the end of 12 weeks (2.0 l, 95% CI, 1.8–2.3 l, n=44, P=0.03) of step-down therapy (Figure 3b). Figure 3 shows only changes in FEV1 and FVC of patients who were adherent to either group and does not include data of patients who withdrew from the study. In the BUD group, patients who withdrew at 8 weeks after treatment (Visit 4) because of poor control of asthma had significantly lower FEV1 (1.5 l, 95% CI, 1.1–1.8, n=9) compared with patients adherent to the step-down therapy or who withdrew for reasons not related to poor control of asthma (2.0 l, 95% CI, 1.8–2.1, n=66, P=0.04). In the CIC group, patients maintained MMEF, a measurement of the small airway function, during the step-down therapy. The MMEF in the CIC group was higher than that of the BUD group (P=0.02), especially after 4 and 8 weeks (CIC, 2.0 l/s, 95% CI, 2.3–1.6 l/s, n=61 vs. BUD, 1.4 l/s, 95% CI, 1.6–1.2 l/s, n=53, P=0.04) (Figure 4).

Figure 3
figure 3

Mean (±95% confidence interval, CI) change from baseline in (a) FVC and (b) FEV1 after 4 weeks, 8 weeks and 12 weeks of treatment in the budesonide (BUD) and ciclesonide (CIC) groups. The P values were calculated by generalised estimating equations (GEE).

Figure 4
figure 4

Mean (±95% CI) change from baseline in maximal mid-expiratory flow (MMEF) after 4 weeks, 8 weeks and 12 weeks of treatment in the ciclesonide (CIC) and budesonide (BUD) groups. Generalised estimating equations (GEE) were used for comparison between two groups. The P values are indicated.

ACT score

Figure 5 shows the difference in ACT scores among asthma patients in the CIC and BUD groups. The ACT scores were not significantly different between the two groups at baseline, but improved in the CIC group after 4 and 8 weeks of treatment compared with baseline (P=0.02 and 0.04, respectively).

Figure 5
figure 5

Asthma control test (ACT) scores after 4, 8 and 12 weeks of treatment compared with baseline. Data were expressed as mean±95% CI. The P values were calculated by generalised estimating equations (GEE).

Patients’ satisfaction rating and physicians’ assessment

At the end of treatment, 63 patients treated with CIC and 61 patients treated with BUD were asked to rate their overall satisfaction (very satisfied, satisfied, neutral, dissatisfied, very dissatisfied) with the trial medication in managing asthma. More patients in the CIC group (70%) were at least satisfied with their treatment, compared with 47.5% of patients in the BUD group (P=0.02). There was also a statistically significant difference in the physicians’ assessment rating in favour of CIC treatment (P=0.002) (Table 2).

Table 2 Summary of the patients’ and physicians’ assessment of treatment

Discussion

Main findings

This study demonstrated that asthmatic patients treated with CIC for step-down therapy fared better than those treated with BUD. After switching to CIC, patients maintained more stable lung function values such as FEV1 and MMEF. Patients treated with BUD, despite a higher equivalent dose of corticosteroids, suffered from more frequent asthma symptoms, resulting in increased withdrawal rates. Patients in the CIC group showed higher adherence, a better patient satisfaction rate and more favourable physician assessment in terms of asthma control when compared with patients in the BUD group. To date, this is the first study that compares a step-down therapy strategy between mono-ICSs from a combination therapy with ICSs and LABAs in patients with well-controlled mild to moderate asthma. Discontinuing LABA therapy in asthmatic patients under a combination of ICSs and LABAs is the main cause contributing to increased asthma-associated impairment,18 but in the studies reviewed fluticasone and BUD were the maintenance ICSs used. Our study indicates that this loss of asthma control during LABA step-off is less likely if the maintenance ICS is CIC.

Interpretation of findings in relation to previously published work

Asthma may be regarded as a disease with three interrelated components: airway inflammation, smooth muscle dysfunction, and airway remodelling. The first two can be effectively treated with corticosteroids and LABAs, respectively.23,24 Despite the lack of an effective treatment for airway remodelling, it is believed that better outcomes can be achieved by appropriate management of asthma. Studies have shown that complementary actions exist between corticosteroids and LABAs, including the differential inhibition of the inflammatory cascade and mutual activation of their respective receptors.25,26 There is compelling evidence showing that, despite the availability of asthma treatment guidelines27 and effective treatments, asthma still remains undertreated.28 There is evidence supporting the view that starting with a moderate dose of ICS and then reducing the dose once asthma control has been achieved is as effective as starting with a very high dose.29 However, there is much less evidence to consider when making recommendations about the best approach to take when stepping down treatment. The GINA guideline27 states that step-down treatment should occur only ‘by agreement between patient and health-care professional, with full discussion of potential consequences including reappearance of symptoms and increased risk of exacerbations.’ This is because once the ICS dose is reduced there may be a slow deterioration in asthma control.30 Considering the side/detrimental effects of the oral or inhalation route of corticosteroids, CIC, a prodrug whose active metabolite shows very pronounced plasma protein binding,9 low free plasma concentrations and, consequently, low cortisol suppression,31 may be an optimal choice for patients for asthma control during step-down therapy. Our results have shown that patients taking CIC had better asthma control over those taking BUD, indicating that CIC may be a good option during step-down therapy.

Small airways play an important role in inflammation and obstruction in asthma, which contributes to the severity of airway hyperresponsiveness as well as asthma control.31 The advantage of small-particle ICSs is that they are able to reach the small airways and target the site of inflammation, consequently resulting in improvement of mid-expiratory flow rates,32 decreased alveolar exhaled nitric oxide levels,7 decreased markers of inflammation in exhaled breath condensate16 and increased efficacy.33 However, it has been demonstrated that ICSs with chlorofluorocarbon (CFC) formulation, like CFC-BUD, have larger particles and are predominantly deposited in the central airways and not in the lung periphery.13,34 Our study demonstrated that the MMEF, a parameter in the detection of obstructive small airway obstruction,35,36 had a gradually significant decrease from the start of treatment up to 8 weeks of the study period in the BUD group, when patients with asthma received step-down therapy with BUD from ICS and LABA (Figure 4). The present study has shown the beneficial effects of CIC, the small-particle ICS, on small airway involvement in asthma, even without the protection of a LABA bronchodilator. In our study, CIC provides effective or equivalent asthma control at much lower doses (320 μg daily) compared with CFC-propelled BUD (800 μg daily) in mild to moderate asthma patients after step-down therapy.

Previous studies reported that subjects with asthma who smoke have an attenuated response to ICSs,37,38 including less increase of morning PEF and FEV1 and increased airway hyperreactivity. The potential mechanisms by which habitual cigarette smoking may induce insensitivity to corticosteroids include enhanced neutrophil-mediated inflammation in smokers.39 Thus, lung deposition of ICS among smokers and nonsmokers may underlie our findings on the differential effects of CIC/BUD on MMEF. However, current smokers have been excluded in this study.

In the BUD group (Figure 3), the value of FEV1 started to reduce at 4 weeks of treatment throughout the study. However, the extent of FEV1 decline did not reach statistical significance compared with the baseline. Data of patients who withdrew from the study because of poor asthma control with significantly lower values of FEV1 were not included in the analysis. The data of FEV1 shown in Figure 3 represent the change in FEV1 of patients who were adherent to step-down therapy or who withdrew for reasons not related to poor asthma control after 4 weeks of treatment. Although more than half of the patients (58.7%) were still adherent to BUD therapy during the step-down from LABA, CIC treatment was apparently better than BUD treatment in terms of adherence rate (76%) and FEV1 and MMEF improvement, despite the equivalent corticosteroid dose of BUD being twice that of CIC.

More than 70% of patients in the CIC group were satisfied with their treatment, whereas only 6.3% of patients reported being dissatisfied. In comparison, only 47.5% of patients in the BUD group were satisfied with their treatment and 19.7% were dissatisfied. During the study period, 27% (20 of 75) of patients in the BUD group but only 5% (5 of 75) of patients in the CIC group dropped out because of asthmatic symptoms. The physicians’ assessment showed the same trend, with better satisfaction (71.8%) rates seen in the CIC group over the BUD group (50.8%). These findings support the notion that the use of CIC is safe and tolerable in the treatment of asthma.

Strengths and limitations of this study

The limitation of this study was its small study population as well as the limited treatment period. As such, this study is unable to demonstrate the long-term efficacy along with safety issues in these groups of asthma patients. Asthma comprises a heterogeneous group of diseases. The baseline data for this study did not include airway hyperresponsiveness or the extent of airway inflammation, which may have an impact on the success rate of step-down therapy. Nevertheless, the results here reveal that step-down therapy with small-particle ICS and the once-daily administration improves adherence rate as well as asthma control, compared with conventional ICS.

Implications for future research, policy and practice

In future, a prospective and crossover study on a larger number of patients is needed to elucidate whether the different effectiveness of CIC compared with BUD in step-down therapy from ICS and LABA combination is attributable to treatment compliance (once daily versus twice daily) or drug efficacy (small particle versus larger particle). More detailed stratification of patients in terms of asthma severity, airway reversibility, airway hyperresponsiveness and extent of airway inflammation (such as exhaled NO) may be beneficial in predicting or improving success in step-down therapy with ICS. However, step-down therapy may be started with ICS only once asthma control has been achieved by ICS and LABA combination therapy. Then, CIC may be an optimal option.

Conclusions

CIC as a step-down therapy from ICS and LABA combination for asthma control is safe, effective and tolerable, with good compliance and a high level of patient satisfaction.