Main

Portal hypertension (PHT), liver cirrhosis and their associated complications are the major causes of morbidity and mortality in the Western world.1 Our knowledge of the pathogenesis and molecular mechanisms of PHT has dramatically increased in recent years.2 In particular, the process of angiogenesis, defined as the growth of new blood vessels from a preexisting vascular tree, and its role in modulating hepatic resistance, portosystemic collateral formation and increased splanchnic blood flow have become the hallmark pathological features of PHT and cirrhosis.3 A variety of methods has been described to obtain valid representations of this newly formed vasculature via in vivo medical imaging (mostly MRI and CT)4, 5 and on post-mortem preparations (including in situ vascular corrosion casting).6

To increase our understanding of these pathologies, the morphological changes should be described with as much detail as possible, but one might also consider the hemodynamic conditions that may be a driving force in the formation of new blood vessels. Vascular corrosion casting has recently revived and has proven to be an excellent tool for detailed three-dimensional (3D) morphological examination of normal and pathological microcirculation.5, 7 In addition, the geometry provided by these vascular casts can be further used to calculate wall shear stress (WSS) in the arterial vascular bed using computational techniques. When blood is in motion, a stress is applied parallel or tangential to the vessel wall, defined as WSS (unit: pascal).8 It has been shown that the mechanical forces applied to vascular walls induce a number of complex cell reactions and modulate gene expression and the secretion of several biomolecules.9 Furthermore, WSS calculations have recently been shown to provide prognostic data in the field of cardiovascular research.10, 11

Although complicated, techniques for the in vivo determination of WSS in the arterial circulation (based on measurement of the flow velocity) exist. However, to our knowledge, these are rarely used in the venous vascular tree and have never been applied in the setting of PHT. In normal circumstances, venous WSS ranges are considerably low,8 but they increase in regions with vascular geometries that promote turbulent flow or increased flow velocity (eg, anastomoses and bifurcations) and therefore, by extension, they can also be applied in the field of PHT.

The aim of this study was to characterize the morphological vascular features and to assess the associated changes in WSS in the portal vein in different animal models of PHT and cirrhosis. The first part of this study focuses on the microvascular morphological changes associated with PHT and cirrhosis. To our knowledge, the obtained results are the first to describe the vascular changes in common bile duct cirrhosis (common bile duct ligation (CBDL)). The second part of this study consists of a quantitative analysis of the WSS in the portal vein in casts of different animal models using computational fluid dynamics (CFD) methods. Provided with the correct fluid characteristics, such as the inlet blood flow of the portal vein, and in combination with geometrical features, these numerical models can accurately predict the WSS in these animal models.12

MATERIALS AND METHODS

Animals

In the first morphological part of the study, male 50% Sv129/50% Swiss mice (5–8 weeks old) were purchased from Harlan Laboratories (Horst, the Netherlands). Although the vascular corrosion casts of these mice were perfectly suited to study changes in the microvasculature, it was difficult to reconstruct reliable 3D models for the second hemodynamic part of the study (ie, WSS measurements). Owing to their larger anatomical dimensions, 11 rats (Wistar, ±200 g, 6–7 weeks old, Harlan laboratories) were used for the CFD analysis in the second part of the study. The animals were kept at a constant temperature and humidity in a 12-h controlled light/dark cycle. The institutional ethical review board at the Faculty of Medicine and Health Sciences, Ghent University, Belgium, approved the protocols.

Mouse and Rat Models of PHT and Cirrhosis

For the first morphological part of this study, mice were used to describe the anatomy, whereas the WSS measurements in the second part of this paper were performed on rats.

A model of secondary biliary cirrhosis (CBDL) and a model for pure PHT (partial portal vein ligation (PPVL)) were induced as previously described.13

Briefly, under inhalation anesthesia with isoflurane (Abbott, Louvain-la-Neuve, Belgium), the common bile duct was occluded with a double ligature of a nonresorbable suture (silk cut 7-0) in CBDL. The bile duct was then resected between the two ligatures. In PPVL, a calibrated stenosis of the portal vein was performed by placing a ligature (silk cut 5-0) around both the portal vein and an adjacent 27-gauge blunt-tipped needle. Subsequent removal of the needle yielded a calibrated constriction of the portal vein.

For the morphological study, experiments were performed 14 days after induction in the PPVL mice (n=9) and 6 weeks after induction in the CBDL mice (n=8). Sham-operated (SO) mice (n=6) were used as controls. Previous studies have demonstrated PHT and a high degree of portosystemic collaterals 2 weeks after PPVL and 6 weeks after CBDL.14, 15

For the WSS analysis, vascular corrosion casts were obtained in four PPVL, four CBDL and three SO rats, and experiments were performed on the same time points as described above.

Mortality rates after PPVL, CBDL and sham induction were 5, 10 and 0%, respectively, and were similar to earlier studies.13

Assessing WSS from CFD in the Portal Vein of Rats: Workflow

The workflow followed to obtain WSS values can be summarized as follows:

  1. 1)

    defining the 3D geometry by casting (Vascular Corrosion Casting),

  2. 2)

    dividing the volume occupied by the fluid in a mesh (Building a 3D Model of a Rat Cast Specimen),

  3. 3)

    defining the physical modeling (using the Navier–Stokes equations for the flow (Numerical Simulations of Blood Flow, Using CFD Analysis in the Portal Vein of Rats)),

  4. 4)

    defining the boundary conditions (by specifying the flow velocities at the boundaries of the geometry (Hemodynamic Measurements)) and

  5. 5)

    solving the equations (Numerical Simulations of Blood Flow, Using CFD Analysis in the Portal Vein of Rats).

These items are further clarified in the indicated paragraphs.

Vascular Corrosion Casting

Following 24-h fasting, animals were killed by intraperitoneal (i.p.) injection of phenobarbital (150 mg/kg) (Nembutal, Ceva Sante Animale, Brussels, Belgium) after proper anesthesia (ketamine (100 mg/kg body weight i.p.; Ketalar, Pfizer, Brussels, Belgium) and xylazine (10 mg/kg body weight; i.p., Rompun, Bayer, Brussels, Belgium)). A midline abdominal incision was performed, and a 26-gauge catheter (Terumo, Leuven, Belgium) was inserted into the ileocolic vein to cast the liver/splanchnic microvasculature (n=6 for PPVL mice, n=4 for CBDL mice and n=3 for sham mice, all rats) and into the inferior caval vein to cast the lung microcirculation (n=3 for PPVL mice, n=4 for CBDL mice and n=3 for sham mice).

For each cast, fresh Batson's solution was prepared using Batson's #17 corrosion kit (Brunschwig chemie, Amsterdam, the Netherlands) according to the manufacturer's recommendations.16 Either 2 or 20 ml of Batson's solution were injected in mice and rats, respectively, through the catheter using 1-ml tuberculin syringes. Animal bodies were immersed for 30 min in tepid water during polymerization and macerated overnight in 25% potassium hydroxide. The vascular corrosion casts were rinsed gently for 3 h with streaming water. Blood vessels were evaluated and photographed with a stereomicroscope (Olympus SZX7, Olympus Belgium, Aartselaar, Belgium) equipped with a charge-coupled device camera (Olympus Colorview, Olympus Belgium). Subsequently, samples of the casts were mounted on a metal stub, platinum-coated (Jeol auto fine coater, JFC 1300, Zaventem, Belgium) and examined by a scanning electron microscope (Jeol JSM 5600 LV). For the first morphological part of the study, the liver/lungs/mesentery of the mice were systematically examined in the different models, but only the particularities were recorded and illustrated in figures.

Morphometric Analysis on Vascular Corrosion Casts of Mice

In order to provide a systematic description of the electron microscopic images, quantitative information was derived from the vascular corrosion casts. The electron microscopic images were characterized morphometrically, taking into account the different issues that can limit a quantitative analysis on casts (Supplementary Methods S1). The samples were screened by scanning electron microscopy at a low magnification ( × 70) to detect the two most vascularized areas (hot spots). Pictures were taken of these hot spots at the appropriate magnification ( × 500 to × 1000) in those areas positioned in a single horizontal plane perpendicular to the orientation of the electron beam (to eliminate false readouts at slightly inclined vessels). The capillary diameter, as a marker of the microvascular dilation in the lung, and the intercapillary distance, as an indicator of the vascular density in the mesentery, were measured quantitatively using computerized image analysis (Cell D, Olympus Soft Imaging Solutions, Münster, Germany). In order to measure a straight line segment as the true diameter (and to avoid skewed oblique distances), measurements of the capillary diameters were performed perpendicular to the longitudinal axis of the vessel wall (Supplementary Methods S2.1.). All intercapillary distances were determined in the mesenteric tributaries with approximately the same vessel size. Standardized measurements were taken between the different ramifications at the base of a long straight capillary mesenteric segment (Supplementary Methods S2.2.). The mean values of all measurements per picture (two pictures per mouse) were determined and averaged with the mean capillary diameter/intercapillary distance of three mice per group. Results were expressed as the mean μm±s.e.m.

Immunohistochemistry: CD31 Staining

Sections from paraffin-embedded tissues (mesentery (three loops proximal to the cecum), liver and lung tissues) of mice were incubated with anti-CD31 antibodies (Supplementary Methods S3). Antigen localization was visualized with 3′-3-diamino benzidene as chromogen. Counterstaining was performed with hematoxylin. These CD31 stainings were correlated with the changes observed on the vascular corrosion casts.

Hemodynamic Measurements

Hemodynamic parameters were recorded before the injection of Batson's solution. Blood pressure was measured using a pneumatic pulse transducer (Marco Bio-systems, Houston, TX, USA) in conjunction with a PowerLab system (AD Instruments, Oxfordshire, UK). To obtain flow data for WSS analysis in rats, an ultrasonic blood flow probe (Transonic Systems, Ithaca, NY, USA) was placed around the portal vein, just above the level of the splenic and mesenteric vein confluence, thereby allowing measurement of the portal venous inflow (ml/min).

Dimensional Analysis in the Portal Vein of Rats

To reveal a trend and rapid snapshot of the magnitude of WSS, a dimensional analysis was performed, yielding results that were averaged over time and space. However, more accurate and precise results were obtained by CFD analysis afterward by taking the 3D geometry and the temporal and spatial variations of the shear stress patterns into account (vide infra).12, 17

A critical input to the dimensional analysis was the mean Reynolds number (Re), which is defined in more detail in Appendix A. The Re is a key dimensionless parameter in fluid dynamics, which expresses the ratio of inertial and viscous forces. It allows the assessment of whether flow is laminar (Re <2000), turbulent (Re >2500) or in a transition phase (2000≤Re≤2500). Assuming that the kinematic blood viscosity (ν) is constant, the Reynolds number is calculated using the mean inlet velocity (V) and mean inlet portal vein diameter of each model. The WSS is computed using Poiseuille's law18 (Appendix A). However, this formula is only valid in laminar steady flow conditions in a straight cylindrical tube and not in more physiological situations. Taking the pulsatile blood flow into account, another dimensionless expression of pulsatile flow frequency in relation to viscous effects is introduced, defined as the Womersley number (α). When α is low, the WSS can be estimated by Poiseuille's law (Appendix A).

Building a 3D Model of a Rat Cast Specimen

The 3D geometry of the cast was acquired with an in-house developed μ-CT. The setup consists of a closed-type X-ray tube with directional target (Hamamatsu Photonics KK, Shimokanzo, Japan) and an A-Si flat panel detector (Varian Medical Systems, Palo Alto, CA, USA). The detector was used in binning 2 mode (0.254 μm pixel size) and 1200 projection images were recorded at 1 s per image while the cast was rotated over 360°. The tube was operated at 80 kV and 180 μA with a magnification of 3.2 (FOV=6 cm), as previously described.12 The reconstruction was performed with Octopus software (Ghent University, Ghent, Belgium), resulting in a 700 × 700 × 700 voxels data set with 79 μm voxel pitch. The obtained images were segmented with Mimics software (Materialise, Leuven, Belgium) to produce a 3D computer model of the portal vein starting just downstream of the level of the splenic vein and including the left and right portal branches. The scanned geometry contained multiple small irregularities, which were trimmed and surface smoothed to create a computational model. The original model was then automatically rescaled according to a simultaneously scanned digital meter scale. To perform blood flow simulations, each model had to be meshed or subdivided into a finite number of small volume elements. Such a volume mesh was created in the TGrid software (Ansys, Canonsburg, PA, USA), and consisted of a boundary layer with prismatic elements near the wall to improve accuracy where it was most needed. The bulk of the model was filled with tetrahedral elements. For 3D computer modeling, an infinite number of volume elements should theoretically be used to exactly approximate the underlying geometry. However, in a numerical study, only a finite number is applicable with the necessity to trade off between physical adequacy and numerical efficiency. In order to address this problem, a mesh-independent study was performed on the original model. We changed the number of volume elements from 5 × 105 to 18 × 105 and the analysis showed that the resulting 95% value (WSS95% as a marker of highest WSS values; only 5% of WSS values are higher than this value) and the spatially averaged WSS (WSSav) remained constant for models containing 12 × 105 elements or more. A mesh density of 12 × 105 elements was therefore used in all models.

Numerical Simulations of Blood Flow, Using CFD Analysis in the Portal Vein of Rats

After having built a 3D volume mesh, CFD software (Fluent, Ansys) was used to numerically solve the Navier–Stokes equations for the flow across the 3D geometry. To calculate a realistic flow field, boundary conditions are needed to provide information on the flow behavior at the in- and outlets of the model. These boundary conditions should ideally be obtained via in vivo measurements of pressure and/or flow at these locations. We imposed a time-dependent velocity profile at the inlet of our model (the inlet of the portal vein) that was calculated from a flow profile measured just downstream of the level of the splenic vein (Hemodynamic Measurements). The flow split at all side branches was calculated using Murray's law, stating that the ratio between the flows to each branch is proportional to the third power of the ratio of the branch diameters. This resulted in an average flow split of 35±8% into the left and 65±8% into the right portal vein, which agrees well with the values obtained by Teleuhan et al,19 who derived a flow split of 70 and 30% into the right and left portal veins, respectively. Rat blood density was taken to be 1060 kg/m3 and the dynamic blood viscosity was assumed to be a constant asymptomatic value of 3.5 mPa.17, 20 The measured inlet profile was divided into 40 time steps, and three cardiac cycles for each of the 40 time steps were calculated. The resulting data of the last cycle were then post-processed in Tecplot (Bellevue, WA, USA). Owing to major differences in the portal vein diameters of two rats (one sham and one PPVL, in comparison with other subjects in the respective groups) resulting from differences in the body weights of these rats at the induction of the model, we decided to rescale these two diameters into the mean portal vein inlet diameters of the sham and PPVL groups, respectively, as was described earlier in previous studies.12

To quantify the difference in WSS between the models, WSSav and WSS95% were computed for each time-averaged model (Appendix A), as well as the oscillatory shear index (OSI) distribution. The latter was introduced to analyze the degree of oscillation: OSI is 0 if WSS always acts in the same direction. However, if WSS is oscillating between positive and negative values, OSI will increase, with 0.5 as a theoretical maximum.21, 22 As endothelial cells are susceptible to the magnitude and changes in WSS direction, high WSSav and OSI values are indirect markers for disturbed endothelial function.12, 23 The spatial distribution of the WSS and OSI (across the wall of the portal vein, time averaged over the total cardiac cycle) and also the temporal variation in WSS (at different time points throughout the cardiac cycle) were calculated and their distributions were plotted.

Statistics

Data analysis was performed using SPSS version 15.0 (SPSS, Chicago, IL, USA). In cases of normally distributed data, groups were compared with the Student's t-test for independent samples. For other types of data, the Mann–Whitney U-test was performed. Data are presented as the mean±s.e.m. or median±range. P-values <0.05 (two-tailed probability) were regarded as significant.

RESULTS

Vascular Architecture in PHT and Cirrhosis in Mice

Splanchnic architecture

Splenorenal shunts were visualized in PPVL mice (Figure 1a). As shown in Figure 1a, a large collateral vessel branched off from the splenic vein and anatomized with the left renal vein. In addition, a newly formed vascular network with irregular, tortuous and immature vessels could be detected as an extrahepatic shunt between the portal vein branches and the inferior caval vein (Figure 1b).

Figure 1
figure 1

Splanchnic vascular cast images of PPVL mice after the injection of Batson's solution into the ileocolic vein. (a) Presence of extrahepatic splenorenal shunt (white arrow head) between the splenic vein and the left renal vein. Note the retrograde filling of the shunt with subsequent demonstration of the dichotomic venous branching of the kidney. The spleen and parts of the liver (dotted line) have been removed to optimize the visibility of the shunt. The flow direction of the Batson's solution has been indicated by the large white arrows. (b) View on a newly formed vascular network with irregular, tortuous and immature vessels (star) between branches of the portal vein (white arrow) and the inferior caval vein (not shown on this image). As indicated, portal vein ligation was associated with numerous tortuous collaterals, bypassing this ligation and favoring the direction of Batson's solution into the route of minimum resistance, that is, the collateral circulation. Small branches of the newly formed vascular network and collaterals are also extending to the inferior caval vein, but because of the dorsal position of this vein these branches are not visible on this figure.

In all PPVL and CBDL mice, the splanchnic vascular density was significantly higher than that in SO mice (Figures 2a, b and e (sham) vs Figures 2c, d and f (PPVL)). This was also reflected by the morphometric analysis of the intercapillary distance, which is inversely correlated with the vascular density. The intercapillary distance was significant larger in the SO animals (145.3±10.9 μm) compared with the PPVL (57.4±25.9 μm, P<0.05 vs sham) and CBDL animals (18.9±7.0 μm, P<0.01 vs sham), reflecting the higher vascular density in portal hypertensive and cirrhotic mice.

Figure 2
figure 2figure 2

Splanchnic vascular cast images of PPVL and sham mice after the injection of Batson's solution into the ileocolic vein. Representative stereomicroscopic and scanning electron microscopic photographs of the mesentery showing increased splanchnic neoangiogenesis in PPVL mice (c, d) in comparison with sham mice (a, b), as also confirmed on CD31 immunohistochemistry (e, f, arrows indicate blood vessels). Sprouting angiogenesis (g, arrows) was observed more frequently in PPVL than in sham mice. Illustration of intussusceptive angiogenesis in PPVL mice is additionally shown (h, arrow).

The splanchnic microvasculature network in PPVL/CBDL mice consisted of multiple vessels with irregular and chaotic branching, numerous blind ends and a lack of hierarchy (Figures 2c and d). This architecture clearly differed in many features from the vasculature of normal tissues (Figures 2a and b). In addition, sprouting angiogenesis was observed more frequently in PPVL animals (Figures 2g and Supplementary Results S1A).

Remarkably, the vessel branches displayed small holes on their walls in PPVL, serving as a marker for intussusceptive capillary growth and representing one of the two principles of microvascular growth, namely nonsprouting angiogenesis (Figure 2h). Venules were identified by their characteristic endothelial cell nuclear imprints (superficial, poorly contoured and irregularly dispersed through the surface) (Supplementary Results S1B). The vasa vasorum externae, which supply the larger veins, were observed as cord-like structures, stretching over and finally penetrating the vessel wall (Supplementary Results S1A). The number of the vasa vasorum in the larger splanchnic veins was not different in PPVL/CBDL animals compared with sham animals. As splanchnic neoangiogenesis in PPVL/CBDL is predominantly present in medium-sized vessels and capillaries, the net effect on the amount of vasa vasorum (in larger vessels) after ligation might be less prominent.

Hepatic architecture

Scanning electron microscopy of CBDL livers revealed marked microvascular changes in comparison with sham livers. Casts of control livers showed normal filling of the sinusoids with a trabecular pattern between columns of hepatocytes (Figure 3a). At the fibrous capsule of Glisson, the sinusoids were not entirely filled with Batson solution, resulting in a Christmas tree appearance with an abundance of small-sized branches encircling the portal venules (Figure 3b). In contrast, CBDL livers displayed a complete loss of architecture with localized obliteration of sinusoids (Figures 3c and d). Note the occurrence of holes in the cast due to bilomas (Figure 3c). By consequence, the irregular, disrupted, bulging and saccular 3D organization of the sinusoids did not allow a more exhaustive morphometric analysis on the hepatic vascular bed.

Figure 3
figure 3

Liver vascular cast images of CBDL and sham mice after the injection of Batson's solution into the ileocolic vein. Casts of control livers showing normal reticular filling of the sinusoids (a, arrows) with liver cell columns (a, circles) between the sinusoids. At the liver capsule, the sinusoids were not entirely filled with Batson's solution, resulting in a Christmas tree appearance with an abundance of small-sized branches encircling the portal venule (b). In contrast, CBDL livers displayed a complete loss of architecture with localized obliteration of sinusoids, leaving a remnant and damaged microcirculation (c). Note the occurrence of holes in the cast due to bilomas (c, circles). Portocentral collaterals are present in the liver, bypassing the sinusoids and shunting blood directly to the hepatic veins (c, d, arrows). These shunts exhibit a leaky appearance, reflecting changes in vascular permeability and yielding easily to leakage of the casting media (d). Representative light microscopic images of CBDL livers (f) confirm the expansion of the vascular structures (larger vessels) and the biliary hyperplasia (holes) compared with sham mice (e).

Large portocentral collaterals that bypassed the capillaries and shunted blood directly to the hepatic veins often appeared in CBDL livers. Small globular extravasations, sticking locally to these collateral vessels, occurred as leakage of the casting media (Figures 3c and d).

In comparison, biliary hyperplasia and vascular proliferation were also present on CD31 immunohistochemistry in CBDL (Figures 3e and f).

Pulmonary architecture

In the normal pulmonary circulation, the capillary arborization is organized into a honeycomb-like network (Figure 4a). The morphology has always been described in both inferior lung lobes, as vascular density is more pronounced therein. Scattered lumpy regions could be recognized due to excessive pressure and rupture of the alveoli in normal and cirrhotic casts (eg, Figure 4b). Cirrhotic mice displayed the same vascular pattern, but larger vessels often appeared in the inferior lobes of cirrhotic mice, shunting blood directly to the lung veins without passing the alveoli (Figures 4b and f). Interestingly, intussusceptive capillary growth was observed more frequently in CBDL mice, although it was also present in normal lungs, as previously described in the development of the normal pulmonary microcirculation in rats (Figures 4c and d).24 The different steps in the generation of new vascular segments by intussusception were clearly illustrated: protrusion of a capillary pillar from opposite sides of the vessel wall into the vascular lumen is followed by perforation of the vessel (Figure 4c) and, ultimately, the splitting into two new vessels (Figure 4d).25

Figure 4
figure 4figure 4

Pulmonary vascular casting images of CBDL mice after the injection of Batson's solution into the inferior caval vein. Casts from normal pulmonary vasculature at the pleural surface showed a vascular arborization, forming honeycomb-like vascular networks (a). Large vessels often appeared in the inferior lobes of cirrhotic mice, shunting blood directly to the lung veins without passing the alveoli (arrow) (b). Scattered lumpy regions, which are due to excessive pressure and rupture of the alveoli (white asterisks) could be recognized (b). Different steps in the generation of new vascular segments by intussusceptive angiogenesis (arrows) are illustrated in (c) and (d). Protrusion of a capillary pillar from opposite sides of the vessel wall into the vascular lumen is followed by perforation of the vessel, ultimately, splitting into two new vessels (arrows). Representative light microscopic images indicate the pulmonary vascular proliferation in CBDL, resulting from these angiogenic processes (e, f, arrows represent vessels).

Previous work26 already indicated that the CBDL model is the only established experimental model that reproduces the physiological features of human hepatopulmonary syndrome (HPS), whereas other commonly used models, such as PPVL, do not result in the development of HPS. As the hallmark feature of the HPS is a microvascular dilatation occurring in the pulmonary artery circulation, the lung capillaries in CBDL/PPVL and sham mice were hereby characterized morphometrically. The capillary width ranged from 7.82±0.29 μm in CBDL animals to 6.95±0.25 μm in PPVL animals, compared with 6.20±0.51 μm in sham mice, confirming the significant microvascular dilatation after CBDL (P<0.05 vs sham). These findings confirm earlier work from Fallon et al26 and Schraufnagel et al27 showing pulmonary vasodilation in CBDL, but not in PPVL and sham animals.

Analysis of WSS in Different Rat Models of PHT and Cirrhosis

Dimensional analysis

Representative measured flow waveforms (ml/min) for the portal venous inflow are shown in Figure 5. The flow rates in the PPVL and CBDL rats were significantly higher in comparison with those in the SO rats (1.54, 1.59, 0.91 ml/min, respectively; P<0.01 PPVL vs sham, P<0.05 CBDL vs sham). The results from the dimensional analysis are summarized in Table 1. The Re at the inlet of the model, indicating whether flow is laminar/turbulent or in transition phase, increased from 115±17 in sham rats to 285±27 and 237±6 in CBDL and PPVL rats, respectively (P<0.01 vs sham and P<0.001 vs sham). The Womersley numbers, taking the pulsatile blood flow into account, varied from 2.9 in the SO rats to 4.1 in the PPVL rats. Although only a trend in WSS can be detected by the dimensional analysis (as idealized Poiseuille flow is assumed), the markedly higher WSS values in PPVL/CBDL rats vs sham were already obvious (P<0.05, both vs sham, Table 1). Importantly, no differences in WSS were shown between PPVL and CBDL.

Figure 5
figure 5

Flow distribution pattern in different animal models of PHT and cirrhosis. Mean flow (ml/min) averaged over 20 cardiac cycles and averaged over three mice. (a) Sham vs PPVL, P<0.05, (b) Sham vs CBDL, P<0.05. The higher portal inflow in the PPVL and CBDL animals results from the splanchnic hyperemia in these models due to low splanchnic arteriolar resistance.

Table 1 Dimensional analysis in the portal vein of different animal models

CFD

CFD analysis allowed us to describe the spatial and temporal variations of WSS in more detail. The spatial distribution of WSS (time averaged over the total cardiac cycle) along the course of the portal vein is shown in different animal models in Figure 6. From an anatomical perspective, the portal vein divides into two large branches, the left and right portal veins, and ramifies further, forming smaller venous vessels. Another tributary of the portal vein is the left gastric vein (or coronary vein), originating just proximal from the left/right portal confluence. In physiological situations, the coronary vein may be occluded or exhibits only a very marginal blood flow. In the setting of PHT, this vein opens, becomes distended and redirects/shunts blood from the portal venous system into the lower esophageal veins and, ultimately, to areas with lower venous pressures (ie, superior vena cava).28 Therefore, the coronary vein was clearly visible on the μ-CT images of the CBDL and PPVL animals, but absent in the SO rats (except in one SO rat, although with a negligible diameter, and therefore excluded during the CFD analysis). The highest WSS values were observed in the PPVL model (WSSav, 68.3±24.5 Pa; WSS95%, 251.0±94.2 Pa) and the CBDL model (WSSav, 5.6±1.1 Pa; WSS95%, 13.4±2.3 Pa) and were significantly higher in comparison with SO rats (WSSav, 1.5±0.3 Pa; WSS95%, 3.8±0.6 Pa) (respectively, P<0.05 and P<0.05 both vs sham), indicating the same trend as previously derived from the dimensional analysis. Interestingly, CFD analysis was able to differentiate CBDL and PPVL rats according to their WSS (P=0.02). Areas with higher WSS levels were located at the dorsal wall of flow splits and around small bulges in the portal vein's contours, in particular, around the ligation in the PPVL model. Variations in OSI, a marker of endothelial function disturbance, are plotted for the PPVL model in Figure 7 (data not shown for CBDL and sham).

Figure 6
figure 6

Wall shear stress (WSS) in the portal vein in the different animal models. Upper panel: Spatial distribution of the WSS in the portal vein, time-averaged over a cardiac cycle. The highest WSS values are observed in the PPVL model in comparison with CBDL and sham. Areas with high WSS were located at the dorsal wall of flow splits and around small bulges in the portal vein's contours, clearly demonstrated around the ligation in the PPVL model (arrow). Lower panel: WSS distribution in the portal vein of PPVL with or without collaterals. The formation of portosystemic collaterals decreased the WSS in the portal vein in comparison with the situation without collaterals. However, normalization of the portal venous WSS was not reached (calculation was executed in two PPVL rats). Owing to the slithering course and the high flow rates of the collaterals, the WSS in these shunts was increased in an effort to relieve the portal vein.

Figure 7
figure 7

Oscillatory shear index (OSI) distribution, as a marker of endothelial function disturbance, in the portal vein of PPVL with or without collaterals. Consistent with the results of WSS distribution in PPVL, the formation of portosystemic shunts in PPVL reduced the average OSI by 55% in comparison with the noncollateral configuration (calculation with and without collaterals was executed in two PPVL rats).

Special care was taken when analyzing the PPVL model. PPVL was associated with numerous collaterals bypassing the ligation. As described above, CFD analysis was first performed without these collateral branches, but in a second calculation, these results were compared with the CFD, including the larger collaterals (Figure 6, calculations were performed in two PPVL rats). Importantly, the inclusion of collateral vessels in PPVL rats resulted in lower WSS values in comparison with the CFD analysis without collaterals (mean decrease 60.7%), but they still remained higher than those values in SO rats (P=0.08). Owing to the slithering course and the high flow rates of the collaterals, the WSS in these shunts was increased.

As expected, the highest WSS was exerted during systole, but it remained different from zero during diastole. The WSS distribution in PPVL at different time steps of the cardiac cycle is displayed in Figure 8.

Figure 8
figure 8

WSS distribution at different time steps of the cardiac cycle in the PPVL model. The highest WSS was exerted during systole, but remained different from zero during diastole.

DISCUSSION

Vascular corrosion casting is an established and well-described method of anatomical preparation that has been used since the middle ages for imaging of hollow organs and vascular systems. Although this technique was initially used for macroscopic purposes, corrosion anatomy is contemporarily applied in both stereo and scanning electron microscopic procedures.6

The first part of this study provides detailed morphological information on the microvasculature in mice models of PHT and cirrhosis. To our knowledge, this is the first study that describes the vascular changes in CBDL cirrhosis. Many features, recently described using molecular techniques in basic hepatology research are hereby confirmed using these vascular casts, such as neoangiogenesis and intussusceptive angiogenesis in different vascular beds of portal hypertensive and cirrhotic mice. In addition, the technique of vascular corrosion casting is an adequate alternative for visualizing angiogenesis and vessel morphology to classical methods such as immunohistochemistry. Both casts and immunohistochemistry can act as complementary techniques as demonstrated in this study in which the morphological changes described on the casts are further substantiated by immunohistochemistry of blood vessels. As recently reported in other studies,29, 30, 31 the casting methodology is sensitive enough to observe sequential microvascular changes after pharmacological or surgical intervention. Morphometrical quantitative studies can be performed on vascular corrosion casts, but are frequently hampered by their inherent dependency on the casting medium properties (eg, shrinkage of Batson's polymer32). Therefore, these quantification have to be interpreted with caution.

Several studies have indicated increased angiogenesis as a key structural feature in the splanchnic, hepatic and pulmonary territory of portal hypertensive and cirrhotic rats.29, 33, 34 Consistent with these reports, the present results are also indicative of splanchnic vascular proliferation in PPVL/CBDL mice (as seen with stereomicroscopic examination and scanning electron microscopy). Electron microscopic evaluation revealed the different steps in the generation of new vascular segments by intussusceptive angiogenesis (splitting angiogenesis) in splanchnic organs of portal hypertensive mice and in the lungs of cirrhotic mice.25 First, a capillary pillar protrudes from the opposite sides of the vessel wall into the vascular lumen, followed by perforation of the vessel. These findings clearly occurred more frequently in pathological animals in comparison with normal healthy mice. In addition, sprouting angiogenesis, defined as tubular extensions from a preexisting vessel forming entirely new vessels, was also identified in diseased animals and was barely present in healthy animals.

Electron microscopy of cirrhotic livers showed marked vascular abnormalities. We hypothesize that changes in blood flow due to significant rheological factors (eg, thrombosis, vasoconstriction or fibrosis) cause narrowing of the sinusoidal lumen, resulting in the obliteration of the normal trabecular pattern of Christmas tree appearance and the shunting of blood in the portocentral collaterals. Furthermore, these collaterals exhibited a leaky appearance, reflecting changes in vascular permeability and yielding easily to leakage for the casting media.

Vascular casting has been used in a variety of pathologies, including human cirrhotic livers35 and CCL4-induced experimental cirrhosis.36, 37 In contrast to CCL4 cirrhosis, CBDL was associated with a more pronounced disruption of the liver architecture on vascular casts. Previous studies have confirmed a markedly lower portal sinusoidal flow in CBDL rats in comparison with those with CCL4 cirrhosis leading to more sinusoidal narrowing and subsequent obliteration of casts in this study.38 In this model of biliary obstruction, different factors (in particular, macronodular cirrhosis, ductular proliferation, biloma formation and prominent inflammatory infiltrates13) contributed to more extensive microvascular and hemodynamic changes in comparison with CCL4 micronodular cirrhosis, leading to an amorphous and deformed vessel organization on vascular casts.

The main novelty reported in this study is the capacity to measure the WSS in the portal vein of different rat models of PHT and cirrhosis. A large body of evidence has demonstrated the influence of WSS on vascular endothelial cells and vascular smooth muscle cells in initiating different events, such as flow-mediated vasodilatation, vascular remodeling and cellular movement.9 To our knowledge, no techniques have been developed to quantify WSS in the portal vein in laboratory animals. Our current knowledge with regard to the mechanisms by which shear stress affects the portal vein is derived from liver perfusion models and in vitro experiments in which monolayers of endothelium are exposed to a well-defined, simple fluid dynamic environment.39, 40, 41, 42 In contrast, CFD methods based on 3D vessel reconstructions in the arterial vascular bed are widely used in the cardiovascular research field and recently provided prognostic data. Our findings demonstrate that deriving WSS using CFD methods is a feasible technique in PHT and cirrhosis, enabling the differentiation between animal models. First, a dimensional analysis was performed, yielding larger WSS values in CBDL/PPVL vs sham animals, as shown in Table 1. The higher portal inflow in the PPVL and CBDL animals resulted from the splanchnic hyperemia in these models, associated with the low splanchnic arteriolar resistance.43 The Womersley parameters were rather small, indicating an almost quasistatic behavior and supporting the use of Poiseuille's law to detect a trend in WSS. The Reynolds numbers were doubled in PPVL and CBDL in comparison with sham animals, as a consequence of the higher inlet portal venous flow, even though the inlet portal vein diameters were rather similar in all groups (Table 1).

Additionally, a CFD calculation was performed to study the spatial and temporal WSS distributions in more detail. Both analyses showed a significant difference in temporally and spatially averaged WSS (WSSav), as well as the 95th percentile of temporally averaged WSS (WSS95%) between sham/CBDL/PPVL animals, with, not unexpectedly, the highest values in the PPVL model. The areas adjacent to the ligation and the dorsal walls of flow splits were the most exposed locations. The highest WSS values in the PPVL model were the consequence of both concomitant changes in flow and manifest variabilities in geometry, whereas the discrimination between sham and CBDL was mainly attributable to flow differences. In agreement with this explanation, CFD analysis was able to differentiate CBDL and PPVL rats according to their WSS, whereas this was not possible in the dimensional analysis, which takes only flow differences and inlet diameters into account.

In addition, the formation of portosystemic collaterals was linked to the WSS distribution in this study. Portosystemic collateral vessels are formed in an attempt to decompress the portal vein by redirecting a fraction of the portal venous flow through these vessels. This results in lower WSS values in the portal vein and higher values in the collaterals (both by higher flow through these vessels and their twisted course in geometry). Although we observed that these shunts are beneficial in relieving the portal vein, as the WSSav was reduced by 60.7% (n=2), no normalization in WSS was attained.

Moreover, this study also addressed the distribution of OSI values in the portal vein in the PPVL model. As endothelial cells are susceptible to the magnitude and changes in WSS direction, areas with high WSSav and OSI values are indirect markers for endothelial disturbances in these PPVL rats.12, 23

Nevertheless, some limitations in the current work might have influenced the obtained numerical results. First, the ideal casting medium does not exist. The physical–technical limitations of the casting medium (particularly viscosity and shrinkage) have to be taken into consideration when interpreting results, especially in morphometric and quantitative studies. Batson's polymer is known to shrink slightly, resulting in a small underestimation of the vessel diameters on casting in comparison with in vivo imaging.6 However, this phenomenon will not influence the general conclusion of this study. Second, the flow splits in both main portal vein branches used in CFD analysis were estimated using Murray's law. Using an ultrasonic blood flow probe, it is technically very difficult to perform flow measurements around the intrahepatic course of the portal branches in rats. Estimating WSS experimentally from velocity profiles recorded noninvasively by means of MRI or ultrasound is, to some extent, easier in a human setting. Although keeping in mind the limitations of translating results from animal models to practice, studying the WSS in different clinical settings in humans may be of interest in characterizing the fluid dynamic environment of the vessel wall in vivo. Third, the performed numerical model cannot include all physiological parameters for pulsatile flow and non-Newtonian behavior of the blood.44 All these aspects were thoroughly investigated in arterial vascular beds in recent studies.45, 46 Nevertheless, in comparison with arterial WSS studies, pulsatile flow can be expected to be of minor importance in a lower-pressure vessel similar to the portal vein. Finally, the use of CFD methods permits only a simulation of the real geometric and hemodynamic differences between models, as it is limited by excessive complexity of the geometry. Besides computational constraints, no flow measurements were possible across all accessory collateral branches in the PPVL model using the current methodology in this paper. Likewise, we were forced to remove the smaller collateral branches in the PPVL model, while preserving the larger ones. However, in a human setting, accurate replication of the in vivo hemodynamics across the (larger) collaterals (by means of MRI) must be taken into account.

In conclusion, this study showed for the first time that vascular casting has an important role, not only in the morphological evaluation of different animal models of PHT and cirrhosis, but also in defining the biological response of the portal vein wall to hemodynamic changes. CFD in 3D geometries can be used to describe the spatial and temporal variations in WSS and to better understand the forces affecting mechanotransduction in the vascular endothelium and smooth muscle cells. In analogy to cardiovascular fluid mechanics, the synergy between CFD modeling and non-invasive imaging of the portal vein can be expected to grow in the future, thereby permitting possible extensions in the clinical domain.

Supplementary Information accompanies the paper on the Laboratory Investigation website (http://www.laboratoryinvestigation.org)