Introduction

The exploration and assessment of structural and functional processes in cells, tissue and other complex systems requires fluorescence optical imaging as a tool for rapid and non-invasive biological monitoring with high spatial and temporal resolution1,2,3. The versatility of today's imaging devices is largely dictated by the photo-physical and photochemical properties of photonic probes. Current methods of optical imaging which employ genetically encoded proteins, organic dyes, semiconductors or persistent phosphors usually exhibit temporal variations in their fluorescence due to their inherently weak photo-stability, blinking behavior or persistent emission characteristics, thus posing great limitations in tracking biological processes4,5,6,7. Alternative photonic probes based on anti-Stokes emission from inorganic phosphor materials appear not only highly suitable as a possible solution for these issues, but they also provide new functionality such as nano-scale thermometry and delayed detection8,9,10,11. Despite their apparent advantages, however, such anti-Stokes probes rely strictly on higher-order excitation. This typically requires high-intensity illumination with laser sources, which often leads to photon-induced deterioration of the analyte. A significant improvement of the anti-Stokes emission efficiency of the employed materials may potentially decrease the operation threshold of the probe, but the fundamental limitation of coherent excitation is still present12,13.

Here, we propose and experimentally demonstrate an effective anti-Stokes photonic probe which operates under incoherent excitation. The probe is engineered to such a way as being capable of separately confining high density electrons and holes for a rather long duration and facilitating their recombination through desired emitters. As shown in Figure 1, upon charging (electron beam, UV light, or X rays), electron-hole pairs are generated and the excited electrons are firmly captured on purposefully introduced trapping states. The mass out-migration of electrons from the ground band leads to the formation of a “satellite valence band” in a high-energy position. Optical pumping with a low- energy incoherent light source at a wavelength of λ1 is then sufficient to extract electrons from this reservoir, followed by electron-hole recombination through an incorporated emitter which is accompanied by the emission of a photon with lower wavelength, λ2. The key feature of this scheme is that the location of the introduced band and the energy gap of the emitter can be rationally tuned. As a result, anti-Stokes emission under incoherent excitation can be obtained, with the added benefits of continuously adjustable frequency shift and broadband excitation. In addition to the anticipated advantage of strongly reduced photo-bleaching during imaging, the approach also overcomes the stringent constraints of the inherently small beam diameter of lasers, thus offering the possibility of rapid optical imaging of tissues over a much larger area14,15.

Figure 1
figure 1

Energy band model depicting anti-Stokes emission under incoherent excitation.

During an optical charging process, the gap between valence and conduction band is decreased by generating an electron-hole pair. The trapped electron mitigates into a satellite trapping band, from where it can be extracted by optical pumping. Emission of a secondary photon with lower wavelength than occurs through recombination of the electron-hole pair.

Results

Establishment of an anti-Stokes photonic probe

The establishment of an anti-Stokes photonic probe requires a material system which is suitable for building a mid-gap electron reservoir. To this end, we have pursued the mixed oxide system Zn-Ga-Ge-O, which has been proven capable of supporting high defect densities, thought to be associated primarily with Ge4+ vacancies (VGe) and O2− vacancies (VO), as well as Zn deficiency16. As the optimal emitter, Cr3+ was chosen and introduced exemplarily into Zn3Ga2Ge2O10 as a probe material. Making use of its defect capacity, such Zn3Ga2Ge2O10:Cr3+has been demonstrated as a near-infrared photo-emitter with surprisingly persistent afterglow16. Here, we target the operating waveband in the biological transparency window of 700–1100 nm. Upon optical charging of the probe, a prominent electron spin resonance (ESR) appears at a g-value of 1.9996 (3374.9 G, Figure 2b). This signal is readily assigned to the presence of trapped electrons17. We also observe that the ESR signal and, hence, the defect state persists over an extended period of time, i.e., >6 hrs (Figure 2b), what is a clear confirmation of the optical storage function of the material. The slight decrease in signal intensity with holding time is attributed to quantum tunneling18. In the photocurrent excitation (PCE) spectra obtained at various temperatures between 20 and 300 K (Figure 2c), a broad excitation band which covers the spectral range of about 250–450 nm is observed. This firmly supports the feasibility of energy charging by ultraviolet-visible (UV-vis) light excitation. Thus, as a preliminary conclusion and confirmation of previous studies, an electron reservoir can effectively be introduced into this specific material system.

Figure 2
figure 2

Properties of an exemplary sample for anti-stokes non-coherent fluorescence probing.

(a) Photograph of an as-prepared disc sample. Scale bar indicate a size of 4 mm. (b) Time-dependent electron spin resonance spectra of the sample after charging. (c) Temperature-dependent photocurrent excitation spectra for the range of 20 ~ 300 K. (d) Luminescence image taken at the interval of 24 hours after charging of the sample for illumination with an incoherent LED operating at a wavelength of 800 nm (here: 7.87 mW/cm2). (e) Static photoluminescence spectrum under excitation at 800 nm and (f) the corresponding photoluminescence excitation spectra monitored at 700 nm of the charged sample. Before measurements, effective optical charging of the probe can be done by UV-vis light for 5 min, the measurements were taken at the interval of 24 hours after charging.

The photoluminescence (PL) spectrum of the charged sample features a broad emission band which is located at ~700 nm (for incoherent excitation at 800 nm with a light emitting diode (LED), Figure 2e). This emission band can be conclusively assigned to the 2E → 4A2 transition of octahedrally coordinated trivalent chromium, VICr3+19. Of importance for the application of the material as fluorescent probe, the emission band can be readily observed even for a fairly low density of excitation irradiation (here: 7.87 mW/cm2, Figure 2d) and plenty of electrons are still detained in the traps even at 24 h after charging. This underlines the potential of the material for low-threshold incoherently excited anti-Stokes emission probing. Noteworthy, no similar luminescence phenomenon can be observed even under high-density coherent laser excitation for the uncharged sample, what confirms the scheme shown in Figure 1 as the basis for the observed photoemission behavior. Figure 2f shows the photoluminescence excitation spectrum of the charged sample monitored at 700 nm. The effective PLE band covers the spectral region from 780 to 900 nm, within which the VICr3+ ion does normally not show any absorption. That is, luminescence occurs as a result of energy transfer from the trapped defect states (Figure 1) to the VICr3+ emitter. The broad width of the excitation band provides a possibility for adjusting the wavelength of pumping source.

Transition kinetics of the emitters

Another intriguing property of the anti-Stokes luminescence based on this energy storage mechanism is the possibility of engineering the radiative transition kinetics of the emitter. In Figure 1, we propose that photo-excited electrons would be captured in traps. This would yield a first fast, subsequently gentle and continuous relaxation process, accompanied by a sustained release of energy. To validate this concept, we consider the luminescence decay kinetics of the sample. The decay profiles are presented in Figure 3. The decay curves don't exhibit a typical single exponential shape (Figure s1). For the initial consideration, the surprisingly slow second decay step is the most relevant. It stands in great contrast to the relatively short lifetime of a few milliseconds which is typically found in rare-earth doped fluorites with maximum anti-Stokes emission performance20. Here, we observe, in comparison, an increase by a factor of ~103 in the timescale of decay, i.e., seconds rather than milliseconds. This makes the present material an almost ideal candidate for application as a robust probe with delayed detection capability (It has been proposed that late time-gating could be used to image molecular or quantum dot imaging probes in the presence of this interference. It is claimed that emission lifetime of nanoparticles larger than several microseconds or milliseconds are considered to be sufficiently long to permit late time-gated imaging.)21. It is also observed that the decay rate exhibits a strong positive dependence on excitation time and excitation intensity: it decreases with longer pumping duration and increases with decreasing excitation intensity. We relate this previously not reported phenomenon to the specific nature of the optical energy storage mechanism.

Figure 3
figure 3

Anti-Stokes luminescence kinetics.

Photoluminescence decay in dependence on duration of excitation (a. constant excitation intensity 0.03 W) and excitation intensity (b. constant excitation duration 2 min) for excitation with a 980 nm laser diode (LD) and monitoring the emission intensity at a wavelength of 700 nm. Before measurements, effective optical charging of the probe can be done by UV-vis light for 5 min, the measurements were taken at the interval of 24 hours after charging.

Stability and reproducibility

The stability and reproducibility of the anti-Stokes luminescence behavior of Zn3Ga2Ge2O10:Cr3+ are illustrated in Figure 4. Even after several hours of continuous irradiation with a LED (7.87 mW/cm2) operating at a wavelength of 800 nm, the anti-Stokes emission remains essentially unaltered in intensity (Ibackground/Ifluorescence ≈ 1/1000, Figure 4a). A similar result was obtained for cyclic operation over 17 individual on/off cycles of 10 min, where a maximum signal degradation of 8% was observed (Figure 4b). Both results indicate the high photo-stability of the material.

Figure 4
figure 4

Anti-Stokes luminescence stability and reproducibility.

(a) Evolution of luminescence monitored at 700 nm under continuous illumination with an incoherent LED (7.87 mW/cm2) operating at a wavelength of 800 nm. (b) Reproducibility of anti-Stokes luminescence generation during 17 on/off cycles over a period of 10000 s. Before measurements, effective optical charging of the probe can be done by UV-vis light for 5 min, the measurements were taken at the interval of 24 hours after charging.

Discussion

The experimental demonstration of anti-Stokes luminescence imaging with incoherent excitation was performed by testing the visibility of the probe inside biological tissue. For that, fluorescence imaging was done by direct injection of disperse particles of Zn3Ga2Ge2O10:0.5Cr3+ into pork tissue. Charging was performed ex situ as well as in situ. Typical fluorescence micrographs are summarized in Figure 5. Figures 5 b–c represent exemplary images taken at the same sample location within a time window of 100 min for ex situ optical charging (Xenon short-arc lamp) of the probe. They clearly show the presence of the probe and its high optical stability which we find, within the observation timescale, in the range of the sensitivity of detection. External (in situ) X-ray activated and recharging of the probe is demonstrated in Figures 5d–f. The probe signal can also be clearly be distinguished from the autofluorescence of the tissue. This shows that the probe can be exploited for multiplexed excitation and detection. The combination of in situ and ex situ X-ray charging capability enables integration with established X-ray medical imaging techniques such as radiography and computed tomography.

Figure 5
figure 5

Anti-Stokes fluorescence tissues imaging of pork tissue with incoherent excitation.

(a–c and g) show the application of ex situ optical charging, (d–f) represent X-ray in situ charging: (a) Pre-injection autofluorescence image. (b) 60 min post-injection fluorescence image and (c) representative reproduction of (b) after 1 on/off cycling. A 980 nm laser diode was employed as the excitation source and the monitoring wavelength was set at ~700 nm. (d) Post-injection autofluorescence image without charging. (e) Post-injection fluorescence image after external X-ray charging and (f) representative reproduction of (e) after 1 on/off cycling. (g) Deep and large-area fluorescence imaging of pork tissue for an injection depth of 1 cm. A 940 nm LED was employed as the excitation source for imaging and the monitoring wavelength was set at ~700 nm. Scale bars are 15 mm for panels a–g. (h) In-vitro viability of BMSCs (bone mesenchymal stem cells) incubated with particulate Zn3Ga2Ge2O10:0.5Cr3+ as anti-Stokes probe at different concentrations for 3 days. Each data point represents the mean value of at least three independent experiments.

The application of an incoherent excitation source potentially enables a notable increase of detection area, as large-area excitation schemes can be employed with less difficulty, for example using large aperture LED sources instead of focused laser beams. While the latter typically enable a detection area ~ 0.5 cm × 0.5 cm, in Figure 5 g, we test simultaneous excitation of an area of ~6 cm2. Clearly, luminescent read-out is achieved over the largest part of excitation area. When the excitation and detection wavelengths locate at near-infrared biological window, the luminescent image can still be visualized even in the case of a large injection depth of 1 cm.

In conclusion, we discuss incoherent anti-Stokes luminescent probing of biological tissue with Zn3Ga2Ge2O10:0.5Cr3+. We show that the high defect capacity of this material enables effective optical charging, before (ex situ) or after (in situ) injection into the analyte. We demonstrate incoherent activation for large-area (~6 cm2) as well as large-depth (~1 cm) detection capability. By regulating the energy level position of the electron reservoir and excitation parameters such as energy, intensity and duration, it provides tunable decay kinetics. Charging of the probe can be done by either X-rays or UV-vis light, what enables multiplexed detection and function integration with standard X-ray medical imaging devices. We believe that overcoming the stringent requirement of coherent excitation for achieving anti-Stokes emission opens new paths for advanced photon management13,22,23.

Methods

Sample synthesis

Different synthesis methods were employed to fabricate samples with various particle sizes. To prepare micro-sized powders, the solid state reaction method was used. The synthesis procedure of Zn3Ga2Ge2O10:0.5Cr3+ as an exemplary material candidate for incoherent anti-Stokes luminescent probing of soft tissue was adopted from Ref. 16 Sample powders and compacted pellets were produced through a conventional solid state reaction of stoichiometric batches of GeO2, ZnO, Ga2O3 and Cr2O3 (≥4N). The reaction comprised a three-step thermal treatment, i.e., initial calcination at 1000°C for 4 h, secondary calcination at 1150°C for 6 h. A part of the obtained powder (~2 g) was pressed into disc-shaped samples with diameters of ~10 mm using an uniaxial hydraulic press and finally sintered at 1350°C for 30 min. To prepare nano-sized powders, a sol-gel procedure was employed. For that, an aqueous precursor solution was prepared by dissolving stoichiometric amounts of zincacetate (Zn(CH3COO)2, 99%), galliumnitrate (Ga(NO3)3, 99.99%), tetraethyl-germanate (C8H20Ge, 99.999%) and chromiumnitrate (Cr(NO3)3, 99%). The solution was stirred vigorously at room temperature about 1 h until it became limpid. During the stirring process, citric acid was added into the solution to form chelate complexes. The solution was then heated to 70°C until a gel was obtained. The wet gel was dried at 110°C for 24 h. The dry gel was finally calcinated at 900°C for 3 hrs. In this way, particles with a size of about 50 nm ~ 300 nm were obtained (Figure s3–s4).

Material characterization

The as-obtained material was analyzed by X-ray diffraction (Cu/Kα), confirming the presence of Zn3Ga2Ge2O10 as the sole crystalline phase. In this lattice, Cr3+ was supposed to precipitate on the octahedral sites of Ga3+24. To study the presence of paramagnetic defects, ESR spectra were recorded with an X-band spectrometer (Bruker A300). Before measurements, effective optical charging of the probe can be done by UV-vis light for 5 min. PCE spectra were measured in a multi-channel spectrometer under monochromatic excitation obtained by the combination of a 300 W Xenon lamp and a monochromator. Before measurement, two gold electrodes with a separation distance of ~1 mm were deposited on the sample for masking. The photocurrent was measured with a digital electrometer under a DC voltage of ~200 V. Spectra were recorded over the temperature range of 20–300 K, employing a closed-cycle liquid He cryostate. Room-temperature PL, PLE spectra and decay curves were measured with a high-resolution spectrofluorometer (Edinburgh Instruments FLS920) equipped with a 500 W Xenon lamp, a 800 nm LED and a 980 nm LD as excitation sources (980 nm LD and 800 nm LED were chosen to demonstrate both the effect of wavelength and intensity of the excitation light on decay rates). Energetic charging of the sample is achieved by exposure to an external field. Effective charging of the probe can be done by UV-vis light/X-ray for 5 min/20 min; the measurements were taken at the interval of 24 hours after charging. The absolute photoluminescence quantum yields (QY) of the micro-sized and nano-sized powders were determined on an FLS920 spectrometer (Edinburgh, UK) with an integration sphere attachment. The QY (pre-irradiated by a UV light) under the excitation of 810 nm light of micrometer size powders is 1.5% (Figure s2), comparable to those of NIR emitting quantum dots and carbon nanotubes, but the QY of nano-size powders is less than 1%. Here, we employed either X-rays (Philips X-pert pro M, 15 min) or UV-vis light (xenon arc lamp, 5 min) and verified the charging process by ESR.

Incoherent anti-Stokes fluorescent probing

As a proof of concept, Zn3Ga2Ge2O10:Cr3+ was employed as an anti-Stokes luminescent probe with incoherent excitation for imaging pork tissue. Nano-particles (Zn3Ga2Ge2O10:Cr3+, dispersed in ordinary saline (100 mg/ml)) were injected into tissue at various injection depths (0.1–1 cm). Tissues imaging was performed with a modified ZKKS-MI-III (Zhongke Kaisheng, Medical Technology Co.,Ltd., Guangzhou, China) tissues imaging system using an external 980 nm LD, 800 nm LED and 940 nm LED as the excited source and an Andor EMCCD as the signal collector. Super-cold filters (Asahi, ZSC1100), long-pass filters (Asahi, ZVL630) and band-pass filters (Asahi, ZBPB147) were inserted to block the excitation light and transmit the emission light. The images were analyzed with Zhongke Kaisheng Imaging Software. In a typical experiment of imaging with ex situ optical charging, the charged particles were injected intramuscularly into the pork tissue. In a typical experiment of imaging with in situ X-ray charging, the uncharged particles were injected intramuscularly into the pork tissue and externally charged by using X-rays. An incoherent 940 nm LED with large aperture (7.87 mW/cm2) was employed as the excitation source for imaging. Deep-tissue imaging was tested by injecting the probe into various depths from 0.1 to 1 cm.

Cytotoxicity

In the cytotoxicity experiment, BMSCs (bone mesenchymal stem cells) were cultured in HDMEM medium (Invitrogen, USA) containing 10% heat-inactivated FBS (fetal bovine serum) at 37°C in the humidified atmosphere with 5% CO2. The cells were seeded in 96-well plates at a density of 10 × 103 cells/cm2 and grew overnight prior to studies. Then, the cells were incubated with fresh media with gradient doses of anti-Stokes fluorescent probes (from 0.1 μg/cm2 to 1000 μg/cm2). After incubation for 3 days, 20 μL of MTT (thiazolyl blue tetrazolium bromide, 10 mg/mL, Sigma–Aldrich, USA) solution was added to each well of the plate and then the plate was incubated at 37°C for 4 hrs. Finally, the cells were lysed using DMSO (Sigma, USA). A microplate reader (Bio-Rad 680, USA) was applied to monitor the absorbance of the supernatants at 495 nm. This experiment was repeated for three times. We observed cellular viabilities of greater than 95% in the presence of injections with a concentration of ≤100 μg/cm2 (Figure 5h), indicating relatively low toxicity of the employed probe.