Introduction

Quantum correlations can be used in a number of ways to enhance metrological performance.1,2,3,4 Highly entangled states such as NOON and GHZ states can enable Heisenberg-limited sensitivity yielding a square root improvement with the number of probes over the standard quantum limit (SQL).5,6,7 This kind of improvement is particularly useful when probing fragile systems where photon damage limits the allowed number of probe photons. This can be the case in, e.g., measuring of biological systems8,9,10 or cold trapped atoms.11 While this effect has been demonstrated in experiments for small probe sizes,11,12,13,14 scaling up the size of the entangled states remains a technological barrier due to their fragility to loss and noise. Other strategies based on the more experimentally accessible squeezed vacuum states have also shown to beat the SQL in various settings.15,16,17,18,19,20 An alternative strategy is to perform multi-pass protocols with a single probe. This enables both Heisenberg-limited sensitivity and super-resolution21 for phase estimation without entangled resources by applying the phase shift to the same probe multiple times.22,23,24 Its experimental demonstration was realized by surrounding the phase shift system with mirrors to measure a transversally distributed phase shift25 or an image26 with Heisenberg-limited sensitivity. While these approaches have demonstrated the effect of sub-shot noise scaling without entanglement, both demonstrations were based on post-selection, rendering the efficiency very low. In addition, the former demonstration could only measure a transversally distributed phase shift requiring a sample size much larger than the beam size. The key problem is that the number of passes through the sample needs to be carefully controlled. For mirror-based approaches, this may be obtained with fast integrated optical routing on the timescale of the roundtrip time between mirrors, which can be very challenging experimentally.

Here we propose a fundamentally different method based on quantum teleportation for realizing quantum enhanced phase measurements. The essence of our proposal is to repeatedly teleport back the probe to coherently apply the phase shift multiple times (see Fig. 1), thus effectively realizing a multi-pass protocol. This circumvents the need for physically redirecting a probe state to the same phase shift multiple times and allows to keep the entangled resources separate from the potentially lossy phase shifting system. Compared to the mirror-based approach, no fast optical routing is required and the setup is more flexible in not having to be confined in between mirrors. We describe how this protocol can be implemented with current technology of continuous variable teleportation using two-mode squeezed vacuum states and an initial coherent state as a probe.

Fig. 1
figure 1

Sketch of the setup. Two optical parametric oscillators (OPO) output single-mode squeezed vacuum states, which can be viewed as a consecutive train of independent squeezed temporal modes illustrated by black dots (a). Interfering the modes on a 50:50 beam splitter results in two-mode squeezed vacuum states shown as connected black dots (b). The bottom modes are input to a fiber delay so they coincide in time with the top mode of the subsequent pair (c). The bottom mode is subject to feedback based on previous measurements (d). This feedback can be implemented by mixing in an auxiliary laser subject to amplitude (AM) and phase (PM) modulation using a high transmission beam splitter (here 99:1). The feedback is part of teleporting back the initial probe state |ψ0〉. The teleported state undergoes a phase shift U(ϕ) (e) before being mixed with the top mode of a two-mode squeezed vacuum pair on a 50:50 beam splitter (f). After the beam splitter, the quadratures of the output states are measured with homodyne detection as part of the repeated teleportation protocol giving the classical feedback shown with double lines (g)

Results

In the general setup, we consider some initial probe in a state |ψ0〉 which is subject to an unknown phase shift described by a unitary \(U(\phi ) = e^{i\phi \hat n}\), where \(\hat n\) is the photon number operator. The goal is to estimate the phase ϕ. After the interaction, an entangled state is used to teleport the output state U(ϕ)|ψ0〉 back to interact with the phase shift again. This process is then iterated m times. If the teleportation is perfect, this would correspond to the transformation |ψ0〉 → (U(ϕ))(m+1)|ψ0〉 = U((m + 1)ϕ)|ψ0〉 of the input state where m is the number of teleportations. By coherently applying the phase (m + 1) times, the signal can have both super-resolution and super-sensitivity since it will now depend on (m + 1)ϕ instead of just ϕ.22,23

As a physical realization of this protocol, we consider the setup illustrated in Fig. 1 where consecutive two-mode squeezed vacuum states are supplied by interferring the output of two single-mode squeezed vacuum sources on a balanced beam splitter.27 One mode is delayed in a fiber and will subsequently be subject to an unknown phase shift described by the unitary U(ϕ). Feedback based on previous measurements is applied before the phase shift. This feedback can be implemented by mixing in an auxiliary laser field using a high transmission beam splitter.27 The delay (T) is chosen such that the phase shifted mode is interfered with the first mode of the subsequent two-mode squeezed vacuum state on a balanced beam splitter before measurement. The setup, which is similar to a Mach–Zehnder interferometer with feedback, is inspired by ref. 28 where the generation of continuous variable (CV) cluster states is demonstrated. As demonstrated in ref. 28, the squeezed light can be produced using optical parametric oscillation (OPO). Binning the temporal modes such that T is larger than the inverse bandwidth of the OPO results in independent squeezed temporal modes. We choose the measurements and the feedback such that the CV teleportation protocol of ref. 29 is realized. In this teleportation protocol, the momentum quadrature of one of the output modes and the position quadrature of the other is measured, which can be achieved with homodyne detection in a single-shot measurement. The feedback consists of quadrature displacement based on the measurement outcomes. For perfect teleportation, infinitely many photons are, in principle, needed in the two-mode squeezed vacuum states. The number of photons actually obtaining the phase shift will nonetheless only depend on the initial input state. For situations where the phase shift is obtained by interaction with a photosensitive system,8,9,10,11 the effective number of probe photons interacting with the system is the limited resource. This number will be \(\sim (m + 1)n_0\) where n0 is the number of photons in the initial state. We will show that Heisenberg-limited sensitivity in terms of probe photons can be reached with a simple coherent state as input state. Furthermore, the phase resolution can be enhanced by a factor of m + 1.

We consider a coherent state |−〉 as the initial probe state |ψ0\(\left( {\alpha \in {\Bbb R}} \right)\). In the setup of Fig. 1, we can input the initial state by displacing the initial vacuum mode of the lower arm using the feedback laser. After the interaction of U(ϕ), the state will be |−iαe〉. This state is now teleported back to the second mode of the first two-mode squeezed vacuum state following the CV protocol of ref. 29 The two-mode squeezed vacuum state has squeezing parameter r such that \(\left\langle {\left( {\hat x_2 - \hat x_3} \right)^2} \right\rangle = e^{ - 2r}/2\), where \(\hat x_2\), \(\hat x_3\) are the position quadratures for the two modes. The first mode of the two-mode squeezed vacuum state is mixed with the probe state on the balanced beam splitter before measurement. The output modes of the beam splitter have position quadratures \(\hat x_1^\prime = (\hat x_1 + \hat x_2)/\sqrt 2\) and \(\hat x_2^\prime = (\hat x_1 - \hat x_2)/\sqrt 2\) with similar expressions for the momentum quadratures. Here \(\hat x_1\) is the position quadrature of the probe state. The quadratures \(\hat p_1^\prime\) and \(\hat x_2^\prime\) are measured giving measurement outcomes \(\{ p_1^\prime ,x_2^\prime \}\). The feedback then implements the displacements \(\hat x_3 \to \hat x_3^\prime = \hat x_3 + g_x\sqrt 2 x_2^\prime\) and \(\hat p_3 \to \hat p_3^\prime = \hat p_3 + g_p\sqrt 2 p_1^\prime\), which concludes the teleportation protocol of ref. 29

The feedback displaces the quadratures such that the teleported state, ψ1 will be close to |−iαe〉. The quality of the teleportation will depend on the amount of squeezing contained in the two-mode squeezed vacuum state and the feedback strength quantified by the gains gx and gp. In the limit of high squeezing, perfect teleportation is obtained for gx = gp = 1. The protocol now repeats itself m times corresponding to m teleportations being performed. At the end of the protocol, the squeezed light sources should be switched off such that the final teleported state |ψm〉 is not mixed with any two-mode squeezed states before measurement. The teleported state |ψm〉 is subject to the phase shift resulting in state \(\left| {\psi _{\mathrm{m}}^\prime } \right\rangle = U(\phi )\left| {\psi _{\mathrm{m}}} \right\rangle\). This state is split by the 50:50 beams splitter (with vacuum in the other input port) and the position quadratures of the output modes are measured and classically added with equal weight of \(1/\sqrt 2\). This is equivalent to measuring the position quadrature \(\left( {\hat x_m^\prime } \right)\) of \(\left| {\psi _{\mathrm{m}}^\prime } \right\rangle\) before the beam splitter and we can therefore simply consider this situation. Assuming gains of gx = gp = 1, the mean and variance of \(\hat x_m^\prime\) is

$$\left\langle {\hat x_{\mathrm{m}}^\prime } \right\rangle = \left\langle {\psi _{\mathrm{m}}^\prime } \right|\hat x_{\mathrm{m}}^\prime \left| {\psi _{\mathrm{m}}^\prime } \right\rangle = \alpha \,{\mathrm{sin}}((m + 1)\phi )$$
(1)
$${\mathrm{Var}}\left( {\hat x_{\mathrm{m}}^\prime } \right) = \left\langle {\psi _{\mathrm{m}}^\prime } \right|\left( {(\hat x_{\mathrm{m}}^\prime )^2 - \left\langle {\hat x_{\mathrm{m}}^\prime } \right\rangle ^2} \right)\left| {\psi _{\mathrm{m}}^\prime } \right\rangle = \frac{{1 + 2me^{ - 2r}}}{4}.$$
(2)

It is clear from Eq. (1) that the signal exhibits super-resolution in ϕ by a factor of (m + 1). The sensitivity of the measurement can be quantified as6

$$\sigma _m = \frac{{\sqrt {{\mathrm{Var}}(\hat x_{\mathrm{m}}^\prime )} }}{{|\delta \langle \hat x_{\mathrm{m}}^\prime \rangle /\delta \phi |}} = \frac{{\sqrt {1 + 2me^{ - 2r}} }}{{2(m + 1)\alpha |{\mathrm{cos}}((m + 1)\phi )|}}.$$
(3)

Note that the sensitivity exhibits a linear decrease in the number of teleportations m as long as |cos((m + 1)ϕ)| ≈ 1 and the squeezing is sufficiently strong such that \(2me^{ - 2r} \ll 1\). For a classical (SQL) strategy with m independent coherent states |−〉, the sensitivity would have a scaling of \(\propto 1/(\sqrt m \alpha )\). The average number of probe photons, nj contained in the state |ψj〉 is

$$n_j = \alpha ^2 + je^{ - 2r},$$
(4)

thus the total average number of probe photons that have interacted with the phase shift system will be

$$n_{{\mathrm{total}}} = \mathop {\sum}\limits_{j = 0}^m n_j = (m + 1)\alpha ^2 + \frac{1}{2}m(m + 1)e^{ - 2r}.$$
(5)

If the coherent state contains one photon (α = 1) on average, we have that \(n_{{\mathrm{total}}} = (m + 1)\left( {1 + \frac{1}{2}me^{ - 2r}} \right)\) and the sensitivity is

$$\sigma _m = \frac{{\sqrt {\left( {1 + \frac{1}{2}me^{ - 2r}} \right)^2\left( {1 + 2me^{ - 2r}} \right)} }}{{2n_{{\mathrm{total}}}|{\mathrm{cos}}((m + 1)\phi )|}}.$$
(6)

Thus, if \(me^{ - 2r} \ll 1\), the sensitivity exhibits Heisenberg scaling in the number of probe photons for |cos((m + 1)ϕ)| ≈ 1. This sensitivity is similar to what could be obtained using NOON states of (m + 1) photons and expresses the ultimate scaling allowed by quantum mechanics.1

Limited squeezing

One of the dominant experimental limitations of the proposed protocol will arguably be the amount of squeezing in the two-mode squeezed vacuum states. This will limit how many teleportations can be performed before the extra noise from the imperfect teleportations will dominate the signal. We therefore consider what the optimum strategy is given a constraint on the amount of squeezing. In addition, we also limit the total average number of photons that can interact with the phase shift system. We then optimize over the number of teleportations m and the size of the coherent probe state α to find the strategy that provides the maximum sensitivity for these limitations. Furthermore, we also allow for arbitrary gains gx and gp. The result of the optimization is shown in Fig. 2 where we illustrate the performance relative to a standard coherent state protocol with matched average photon number. For such an approach, the sensitivity is simply \(\sigma _{{\mathrm{coh}}} = 1/\left( {2\sqrt {n_{{\mathrm{total}}}} |{\mathrm{cos}}(\phi )|} \right)\) where ntotal is the average number of probe photons. For |cos(ϕ)| ≈ 1, the coherent state approach exhibits sensitivity at the SQL. Figure 2 shows the two effects of the imperfect teleportation; noise is added in the \(\hat x\)-quadrature (see Eq. (2)) and more photons are added to the probe state (see Eq. (5)). In the minimization, the error from the extra photons added by an imperfect teleportation has smaller weight for higher ntotal. In the limit where \(n_{{\mathrm{total}}} \gg e^{2r}\), the enhancement is \(\sim e^r/\sqrt 2\) and equal gains of gx = gp = 1 are optimal. This is the limit where the extra photons added to the probe state do not have any significant effect on the optimum performance. We note that a similar enhancement in sensitivity could be obtained by using a squeezed coherent state as probe.15,30 For such protocols, the squeezed photons, however, interact with the phase shift system, which is not the case here. Consequently, our protocol also works in the limit \(n_{{\mathrm{total}}} \ll e^{2r}\) where an enhancement of \(\sim \left( {n_{{\mathrm{total}}}e^{2r}/2} \right)^{\frac{1}{4}}\) can be obtained for gx = gp = 1. Note that our numerical optimization shows that larger enhancement can also be obtained for optimized gains in this limit (see Fig. 2b). Finally, we note that no enhancement is possible when \(r \lesssim 0.35\) for gx = gp = 1 since the extra amplitude noise added by the teleportation cancels the gain in the signal (see Eq. (3)). For optimized gains, however, there can be a small enhancement.

Fig. 2
figure 2

Performance for finite squeezing. Maximum gain in sensitivity by using the teleportation scheme compared to a classical coherent state protocol for limited amount of squeezing (r) and fixed average number of total photons ntotal. We have assumed that |cos((m + 1)ϕ)| ≈ 1. The performance is better for high ntotal because here the photons added to the probe states by imperfect teleportation have smaller weight compared to the extra noise added to the quadrature. We have assumed gains of gx = gp = 1 in (a) while we have numerically optimized the gains in (b). It is seen that in the limit \(n_{{\mathrm{total}}} \lesssim e^{2r}\) the optimal gains are different from gx = gp = 1. The optimal number of teleportations m found in the optimizations are indicated with circles, squares and diamonds. These indicate the transitions to m ≥ 10, 100, and 1000, respectively, on the curves

Photon loss

One of the technological challenges of using highly entangled quantum states for enhanced phase measurements is that they are very fragile to losses. Multi-pass protocols share this fragility since losses grow exponentially with the number of passes through the sample.24 This means that if the losses are too high, the sensitivity enhancement of the multi-pass protocol proposed here will vanish. Note however that while approaches based on NOON states rely on single photon detection, this protocol is based on homodyne detection, which in practice is much more efficient. Since imperfect photon detection will add to the overall loss, this means that the effective loss may be substantially reduced with this protocol.

We investigate the performance of the proposed protocol in the presence of both loss acting on the probe state corresponding to a lossy phase shift system and loss acting on the two-mode squeezed vacuum states. Any (symmetric) detection loss would add directly to both of these losses. We model the losses with fictitious beam splitters where the unused output port is traced out. To model the lossy phase shift system, a fictitious beam splitter of transmission η1 is inserted after the phase shift U(ϕ) (see Fig. 1). For the loss in the two-mode squeezed vacuum state, fictitious beam splitters both with transmission η2 are inserted for each of the modes. For simplicity, we have assumed equal losses for both modes. Assuming equal gains of gx = gp = 1, the signal and sensitivity after m teleportations for {η1, η2} < 1 is

$$\langle \hat x_m^\prime \rangle = \alpha \eta _1^{\frac{{m + 1}}{2}}{\mathrm{sin}}((m + 1)\phi )$$
(7)
$$\sigma _m = \frac{{\sqrt {1 + 2\eta _1\frac{{1 - \eta _1^m}}{{1 - \eta _1}}\left( {\eta _2e^{ - 2r} + 1 - \eta _2} \right)} }}{{2(m + 1)\alpha \eta _1^{\frac{{m + 1}}{2}}|{\mathrm{cos}}((m + 1)\phi )|}}.$$
(8)

As expected, the loss on the probe state (η1) enters in the expression for the sensitivity exponentially in m, while loss on the two-mode squeezed vacuum states (η2) only has a linear effect in m. The effect of η2 < 1 on the sensitivity is equivalent to having a limited squeezing of \(r_{{\mathrm{lim}}} = - \frac{1}{2}ln\left( {\eta _2e^{ - 2r} + 1 - \eta _2} \right)\). This also holds when considering the average number of total probe photons incident on the phase shift system. For m teleportations and gains of gx = gp = 1, we have that

$$n_{{\mathrm{total}}} = \frac{{1 - \eta _1^{m + 1}}}{{1 - \eta _1}}\alpha ^2 + \frac{{m(1 - \eta _1) - \eta _1(1 - \eta _1^m)}}{{(1 - \eta _1)^2}}\left( {\eta _2e^{ - 2r} + 1 - \eta _2} \right).$$
(9)

Note that by taking the limit η1 → 1 for η2 = 1, Eqs. (7)–(9) reduce to Eqs. (1), (3) and (5). If excess noise on the squeezed states is included by mixing in thermal states of average photon number \(\bar n\) instead of vacuum in the fictitious beam splitters (η2), one would have that \(r_{{\mathrm{lim}}} = - \frac{1}{2}ln\left( {\eta _2e^{ - 2r} + (1 + 2\bar n)(1 - \eta _2)} \right)\). We will assume that \(\bar n \ll 1\) such that excess noise can be neglected. To see the effect of finite losses, we again compare the protocol to the simple coherent strategy for which \(\sigma _{{\mathrm{coh}}} = 1/\left( {2\sqrt {\eta _1n_{{\mathrm{total}}}} |{\mathrm{cos}}(\phi )|} \right)\) in the presence of loss. The result of the optimization is shown in Fig. 3. While a small improvement was found by optimizing the gains, near optimal performance is reached for gx = gp = 1. The error from losses in the two-mode squeezed vacuum state limits the gain in the same way as finite squeezing does for the lossless case. Consequently, when these losses dominate the error, the enhancement is \(\sim 1/\sqrt {2(1 - \eta _2)}\) and no enhancement is possible for η2~1/2. When losses in the probe state limit the enhancement, the optimum performance is effectively found as a tradeoff between the \(\sqrt {m + 1}\) enhancement due to the teleportation and the exponential reduction due to the loss. As a result, we find that the enhancement is \(\sim \sqrt {2/(3(1 - \eta _1))}\) and no enhancement is possible for η1 ~ 1/3. We note that while losses quickly reduce the enhancement, the scheme still exhibits enhanced sensitivity compared to the standard coherent state probe even for substantial losses.

Fig. 3
figure 3

Performance with loss. Maximum gain in sensitivity by using the teleportation scheme compared to a classical coherent state protocol for limited amount of squeezing (r) and fixed average number of total photons ntotal = 100 in the presence of a loss on the probe state (η1 < 1, η2 = 1) and b loss on the two-mode squeezed vacuum state (η1 = 1, η2 < 1). The optimal number of teleportations m decreases as the loss increases. The circles (squares) indicate the transition where m ≥ 10 (m ≥ 100). We have assumed that |cos((m + 1)ϕ)| ≈ 1

Discussion

In conclusion, we have shown how both super-sensitivity and super-resolution can be obtained for an optical phase measurement using continuous variable quantum teleportation based on two-mode squeezed vacuum states. For negligible losses, the protocol can exhibit Heisenberg-limited sensitivity (~1/N) for squeezing \(2Ne^{ - 2r} \ll 1\) and increase the resolution by a factor of N, where N is the number of probes. While this is equivalent to the enhancement possible with N-photon NOON states and single photon detection,6 the protocol proposed here relies on homodyne detection, which generally is more efficient than single photon detection. As a consequence of the super-resolution, the phase to be estimated should, in principle, be localized within a window of 1/N to reach the Heisenberg limit as for a NOON or GHZ state approach.1,5 However, methods developed to estimate arbitrary phases,19,31 in particular, for NOON32 and GHZ states,33 might also be employed in a straightforward way to this scheme. The latter method uses GHZ states of different sizes in order to estimate the digits of the phase allowing for arbitrary phase estimation.33 The same technique could be employed here by operating with different number of teleportations before readout, which effectively corresponds to sending entangled states of varying sizes. We have also studied the effect of photon loss on the scheme both for loss in the two-mode squeezed vacuum states used for teleportation (limits the effective squeezing) and for loss on the probes corresponding to a lossy phase shift system. While loss quickly reduces the performance, the protocol may still provide super-sensitivity for loss on the order of several percent. For an effective squeezing of 13 dB (r = 1.5), a 6 dB enhancement of the sensitivity (σ2) may be obtained even with 10% loss in the phase shift system for ntotal = 100 using m = 12 teleportations. For a more modest squeezing of 8 dB (r = 0.92), a 3.5 dB enhancement may be obtained under the same conditions with m = 6 teleportations.

While the specific protocol studied here employed CV teleportation of a coherent state with two-mode squeezed vacuum states, the generic setup of teleporting back a probe state to interact with the phase shift system multiple times may be extended to other scenarios. In particular, our method can be easily extended to a multi-mode scheme to demonstrate Heisenberg-limited imaging. This can be realized by replacing the single-mode teleportation scheme with a multi-mode scheme in which multiple higher-order spatial modes are simultaneously teleported.34 Using such a multi-mode approach, sub-shot noise and eventually Heisenberg-limited microscopy can be realized. Non-Gaussian states such as photon subtracted two-mode squeezed states35 may also be considered for enhanced teleportation performance or different probe states providing better single-shot estimation.7 A discrete variable variant of the protocol could also be envisioned using one-dimensional cluster states emitted by single quantum emitters.36 Here every second qubit could probe the phase shift while the remaining qubits are used to teleport the phase information.

Methods

We evaluate the performance of the teleportation protocol using the Wigner functions37 of the photonic modes. The two-mode squeezed vacuum state has Wigner function

$$W_{{\mathrm{sq}}}(x_2,p_2,x_3,p_3) = \left( {\frac{2}{\pi }} \right)^2e^{ - e^{ - 2r}\left( {(x_2 + x_3)^2 + (p_2 - p_3)^2} \right)}e^{ - e^{2r}\left( {(p_2 + p_3)^2 + (x_2 - x_3)^2} \right)},$$
(10)

with (x2, p2) and (x3, p3) describing the position and momentum quadratures of the two modes, respectively. Photon loss and excess noise is included by mixing both modes with thermal fields of average photon number \(\bar n\) on fictitious beam splitters of transmission η2 (assumed equal for both modes). The input modes before the beam splitters are described by the Wigner function

$$W_{{\mathrm{noise,in}}} = W_{{\mathrm{sq}}}(x_2,p_2,x_3,p_3)W_{{\mathrm{th}}}(x_{2t},p_{2t})W_{{\mathrm{th}}}(x_{3t},p_{3t}),$$
(11)

where

$$W_{{\mathrm{th}}}(x,p) = \frac{1}{{\pi \left( {\bar n + 1/2} \right)}}e^{ - \frac{1}{{\bar n + 1/2}}\left( {x^2 + p^2} \right)}.$$
(12)

The action of the beam splitters corresponds to making the transformation

$$\begin{array}{l}x_2 \to \sqrt {\eta _2} x_2 + \sqrt {1 - \eta _2} x_{2t}\\ p_2 \to \sqrt {\eta _2} p_2 + \sqrt {1 - \eta _2} p_{2t}\\ x_{2t} \to \sqrt {\eta _2} x_{2t} - \sqrt {1 - \eta _2} x_2\\ p_{2t} \to \sqrt {\eta _2} p_{2t} - \sqrt {1 - \eta _2} p_2,\end{array}$$
(13)

in Eq. (11) together with a similar transformation for x3, p3, x3t, and p3t. The noise modes (x2t, p2t) and (x3t, p3t) are then traced out by integration. The resulting Wigner function describes the noisy two-mode squeezed input states for the teleportation protocol and is denoted \(W_{{\mathrm{sq}}}^{{\mathrm{in}}}(x_2,p_2,x_3,p_3)\).

The probe state is in general described by a Gaussian Wigner function of the form

$$W_{{\mathrm{p}},i}^{{\mathrm{in}}}(x_1,p_1) = ce^{ - \alpha _xx_1^2 - \alpha _pp_1^2 + \beta x_1p_1 + \lambda _xx_1 + \lambda _pp_1 + \gamma }.$$
(14)

where c, αx, αp, β, λx, λp, γ are constants. For the initial coherent state probe (|−〉 with Wigner function \(W_{{\mathrm{p}},0}^{{\mathrm{in}}}\)), we have that \(c = \frac{2}{\pi },\alpha _x = \alpha _p = 2,\beta = 0,\lambda _x = 0,\lambda _p = - 4\alpha ,\gamma = - 2\alpha ^2\). The phase shift of the probe state makes the (unknown) transformation x1 → cos(ϕ)x1 + sin(ϕ)p1, p1 → cos(ϕ)p1 − sin(ϕ)x1 in Eq. (14). Loss is modeled by subsequently mixing with a vacuum mode (Wth with \(\bar n = 0\)) on a fictitious beam splitter of transmission η1 and tracing out the output noise mode as with the two-mode squeezed vacuum states. The resulting state is described by a Wigner function \(W_{{\mathrm{p}},i}^{{\mathrm{out}}}(x_1,p_1)\).

The noisy two-mode squeezed input states, \(W_{{\mathrm{sq}}}^{{\mathrm{in}}}(x_2,p_2,x_3,p_3)\) are now used to teleport the probe state \(W_{{\mathrm{p}},i}^{{\mathrm{out}}}(x_1,p_1)\) back to interact with the phase shift again. The mode (x3, p3) is assumed to be the delayed mode and the goal is thus to teleport the mode (x1, p1) back to this mode. This is done by mixing the modes (x2, p2) and (x1, p1) on a 50:50 beam splitter, measuring the output quadratures and providing feedback on the modes (x3, p3). The input state before the 50:50 beam splitter has the Wigner function

$$W_{{\mathrm{tel,in}}} = W_{{\mathrm{sq}}}^{{\mathrm{in}}}(x_2,p_2,x_3,p_3)W_{{\mathrm{p}},i}^{{\mathrm{out}}}(x_1,p_1).$$
(15)

The beam splitter makes the transformation

$$\begin{array}{l}x_1 \to (x_1 + x_2)/\sqrt 2 ,\quad p_1 \to (p_1 + p_2)/\sqrt 2 \\ x_2 \to (x_1 - x_2)/\sqrt 2 ,\quad p_2 \to (p_1 - p_2)/\sqrt 2 \end{array}$$
(16)

in Eq. (15). The measurements of the quadratures p1 and x2 and corresponding feedback on mode (x3,p3) are then described by first making the transformation \(x_3 \to x_3 - g_x\sqrt 2 x_2\), and \(p_3 \to p_3 - p_x\sqrt 2 p_2\) in the Wigner function and then integrating out modes (x1, p1) and (x2, p2). The corresponding teleported state corresponds to probe state \(W_{{\mathrm{p}},i + 1}^{{\mathrm{in}}}(x_1,p_1)\). The process can then be repeated to get the next iteration. After a fixed number of teleportations m, the phase shift is estimated from measurement of 〈x1〉 for the light described by Wigner function \(W_{{\mathrm{p}},m}^{{\mathrm{out}}}(x_1,p_1)\). All moments of x1 and p1 can be extracted from \(W_{{\mathrm{p}},m}^{{\mathrm{out}}}(x_1,p_1)\), which makes the calculation of the sensitivity straightforward. Note that the mean number of photons contained in the state is \(n_m = \langle x_1^2\rangle + \langle p_1^2\rangle - 1/2\).

Numerical optimization

For arbitrary gains gx and gp, it becomes infeasible to find a closed analytical expression for the sensitivity for an arbitrary number of teleportations m. For Figs. 2 and 3, we have therefore numerically minimized the sensitivity in both the number of teleportations (m), the gains (gx, gp) (assumed fixed for each iteration), and α for given values of the squeezing parameter (r) and photon loss (η1, η2). In the optimization, we use the analytical expressions for the teleported state derived as described above. By inserting the numerical values for the constants (c, αx, αp, β, λx, λp, γ), we can repeatedly iterate the protocol and get the values of the constants for the final Wigner function \(W_{{\mathrm{p}},m}^{{\mathrm{out}}}(x_1,p_1)\) after m teleportations. From this, the sensitivity and the mean number of probe photons can be calculated. The optimal m, gx,gp, and α are then identified as the ones that minimize the sensitivity under the constraint of a fixed number of total probe photons.