Introduction

The utilisation of renewable energy in the process of water electrolysis to produce green hydrogen offers significant promise for decarbonisation in many sectors. It is projected that by the year 2050, around 86% of the entire global annual power generation, amounting to 55,000 TWh, will be derived from renewable energy sources1. However, it is worth noting that up to 40% of the overall renewable electricity may be wasted due to the intermittent and variable characteristics inherent in renewable energy production2,3,4. The power-to-hydrogen (P2H) system provides a flexible approach to use renewable energy to produce green hydrogen (H2) via water electrolysis to minimise renewable energy wastage. Currently, over 400 P2H projects are being planned or constructed using renewable energy, mainly in European countries (comprising ~70%) (Fig. 1a), for completion by 2030. P2H projects are also expected by 2050 in North African countries, India, China, Chile, Australia, and Saudi Arabia, driven by their abundant renewable resources and diverse strategies towards a low-carbon economy1,5,6. However, to limit global warming to well below 2 °C and achieve climate neutrality by 20507, electrolyser capacity must increase 6000–8000-fold7,8. Such high green H2 yields to meet city-scale energy require large amounts of water (i.e. 10‒15 L of water per kg of H2). Water is particularly valuable and crucial in areas prone to the risks of water scarcity or quality deterioration, including Northern China, the Middle East, North Africa, and India (Fig. 1a)9. However, it is noteworthy that around 30% of ongoing or planned P2H projects are located in regions where populations facing water scarcity are projected to increase up to 154% by 205010. These issues pose a potential constraint on the wide application of the P2H strategy11.

Fig. 1: Water risk atlas with planned H2 projects and the FOWSAWE system.
figure 1

a The distribution of hydrogen projects worldwide is categorised in small-scale (<100 MW), medium-scale (100–1000 MW), and large-scale (>1000 MW) according to water risk. The map was built using Geographic Information System (GIS) software by combining data from two global databases, i.e. water-related risk information across large geographies from the World Resources Institute (WRI) Aqueduct55 and a worldwide database of hydrogen projects compiled by the International Energy Agency (IEA)56 b Schematic diagram illustrating the FOWSAWE system for green hydrogen production from municipal wastewater effluent.

Several strategies propose alternative water sources, mostly seawater, for utilisation in P2H systems. Direct seawater electrolysis results in limited electrolyser lifespan and low H2 production rates due to various factors including the precipitation of cations such as calcium and magnesium at the cathode, electrode corrosion, and the formation of parasitic chlorine by-products at the anode12,13,14,15. Seawater desalination via reverse osmosis (RO) before electrolysis is often employed for H2 production, but it is hampered by membrane fouling16,17. Incorporating forward osmosis (FO) before RO (FO–RO) mitigates membrane fouling, but it increases costs due to the secondary processes required to separate the clean water and regenerate the draw solution17,18,19.

Recent advancements in membrane-assisted seawater electrolysis offer a promising future for P2H solutions. By incorporating a hydrophobic polytetrafluoroethylene (PTFE) membrane, water can be extracted from seawater as vapour which subsequently undergoes hydrolysis20. Similarly, coupling FO to water electrolysis (FOWS) can extract water under an osmotic gradient, and the extracted water is sequentially hydrolysed to sustain continuous operation21. Such innovative systems eliminate the need for energy-intensive RO and the additional steps to separate clean water before entering the electrolyser, thus reducing capital and operational costs (Supplementary Table 2)17,21,22. However, both systems yield H2 at <30 Nm3 day–1 m2 of membrane area, due to the low vapour pressure gradient driving the water flux across the PTFE membranes, the low conductivity of pH-neutral draw solutions in FO for electrolysis, and the high osmolarity of seawater, consequently restricting fast P2H conversion and its large-scale application21,22,23. We hypothesise that utilising potassium hydroxide (KOH) for FOWS is more efficient because KOH ensures high current densities to split the water via alkaline water electrolysis (AWE) and may serve as a suitable draw solution for FO to provide an osmotic gradient to extract water if coupled with a KOH-compatible FO membrane. Although acidic media may also enhance FOWS, using KOH is preferred as it allows the use of cost-effective materials (i.e. nickel) and minimises chlorine by-products due to higher overpotential and slower chlorine evolution reaction (CER) kinetics24,25. Further, the technological maturity of AWE compared to the acidified ones ensures superior safety, reliability, and scalability. We also hypothesise that wastewater effluent as an alternative water source is better than seawater, as it enhances water production due to its lower osmolarity, presents less chloride for CER, and generates less hazardous brine which is costly for disposal26,27,28,29. Additionally, using wastewater effluent is more practical than seawater, especially for inland communities where water resources are scarce and seawater is unavailable but where wind and solar farms can provide green electricity to drive P2H systems30. This background information addresses the need to better understand the selection of FO membrane materials and electrolytes, and the impacts of impurities in wastewater effluent on the H2 production rate of the FOWS system, and the operational versatility and stability of the system.

Here, we describe a FOWSAWE system that integrates FO and AWE utilising KOH as the shared operational solute to enable continuous H2 production directly from wastewater effluent (Fig. 1b), achieving an impressive H2 production rate of 448 Nm3 day–1 m2 of membrane area, over 14 times faster than the state-of-the-art seawater electrolysis21,22. Such fast H2 production arises from the employed semi-permeable thin-film composite (TFC)-FO membrane, which tolerates KOH concentrations up to 1 M, allowing the use of KOH as a draw solution to enhance water production from wastewater and as the optimal electrolyte to produce H2. The FOWSAWE system also shows consistent stability, maintaining a stable cell voltage of 1.79 ± 0.01 V during the entire testing period and a high Faradaic efficiency of ~99% even with some impurities from wastewater permeating through the FO membrane. It achieved a specific energy consumption (SEC) (i.e. average energy consumption for producing Nm3 of H2) of ~4.43 kWh Nm–3 at 23 °C, which is comparable with commercial alkaline electrolysis using deionised water, and further reduced to 3.96 kWh Nm–3 at 40 °C. Moreover, the highly modular FO and AWE units, in combination with our developed water-hydrogen balance model, allow for equalising the rates of water production from FO and those of water consumption from AWE. This flexibility allows the FOWSAWE system design to meet various scales with different water sources. Thus, our approach for fast and energy-efficient H2 production from wastewater by the highly modularised FOWSAWE system demonstrates a promising strategy for the large-scale and sustainable P2H practice.

Results and discussion

Producing clean water via FO using KOH as a draw solution

To integrate FO with AWE, KOH and two other electrolytes including sodium bicarbonate (NaHCO3), and potassium pyrophosphate (K4P2O7) were considered as potential draw solutions for FO instead of the conventional NaCl, as NaCl induces a CER, which negatively affects H2 generation and damages both the FO membrane and electrodes30,31,32,33. Among these electrolytes at a concentration of 1 M, KOH shows current densities 18 and 12 times higher than those of NaHCO3 and K4P2O7 at 2 V, respectively (Supplementary Fig. 1). The higher current density of KOH represents a higher H2 production rate in AWE compared to the other two electrolytes. To not compromise the AWE performance, we tested if KOH could be used as the draw solution in FO for extracting water from simulated wastewater effluent containing sodium acetate (NaAc), ammonia/ammonium ions (NH3/NH4+), and chloride. Besides, although the current density of KOH increases with increasing concentration34, KOH at concentrations higher than 1 M causes the pH of the draw solution to exceed 14, which carries the risk of damaging commercial TFC-FO membranes. Therefore, we tested 1 M KOH to evaluate its impact on the TFC-FO membranes (details given in the Methods section).

Figure 2a shows the water flux (i.e. the permeated water volume per unit of time and per unit of membrane areas, L h–1 m–2 (LHM)) and reverse salt flux (RSF) (i.e. draw solute permeated to the feed solution side per unit of time and per unit of membrane areas, g h–1 m–2 (GHM)) of the FO process using 1 M KOH as the draw solution for five cycles of five hours each. The water flux decreased from 17.2 ± 0.3 to 14.9 ± 0.1 LHM after 5 h in each cycle, while the RSF remained constant at ~121 ± 3 GHM. The water flux is comparable to a system using NaCl as a draw solution (Supplementary Fig. 2), indicating that the KOH is an effective draw solution to extract water through FO processes. The primary concern associated with the use of KOH as a draw solution is its potential to damage the FO membrane, as the reverse flux of KOH may cause hydrolysis of the polymer chains that constitute the membrane selective layer (on the feed side)35. The integrity of the commercial TFC-FO membrane after operating in 1 M KOH solution was examined by comparing the water flux and RSF of the used membrane after the tests shown in Fig. 2a and a new pristine membrane, both using deionised water as the feed solution and 1 M NaCl as the draw solution (Fig. 2b). Figure 2b shows that the water flux of the used membrane was reduced by less than 5% compared to the pristine membrane, while the RSF of the two membranes was comparable. The membrane integrity in terms of water flux and RSF was not compromised. In addition, results from scanning electron microscopy (SEM) revealed no change in the “leaf-like” surface of the selective layer on the unused membrane and the used membrane after five cycles (Fig. 2c, d and Supplementary Fig. 3a, b) and in the peaks of the functional groups in the Fourier transform infra-red spectroscopy (FTIR) (Supplementary Fig. 4). The comparable water flux and RSF between the pristine and the used membrane suggest that the FO membrane was not damaged by KOH. The high RSF may be attributed to the smaller hydrated ionic size and higher ionic mobility of KOH36, or the ionisation of the membrane via deprotonation of the functional groups on its surfaces facilitating the transport of cations across the membrane37,38. Nonetheless, the RSF accounted for less than 1.5% of the initial KOH concentration after a cycle, suggesting the impact due to this issue was minor. Moreover, since KOH is inexpensive, any losses can be easily replenished in the system.

Fig. 2: Impacts of using KOH as a draw solution of FO processes to extract clean water from wastewater effluent.
figure 2

a Water flux (Jw) and reverse salt flux (RSF) of the FO process with simulated wastewater effluent containing sodium acetate, NH3/NH4+, and chloride as feed solution and 1 M KOH as draw solution for five cycles. The dashed lines represent five cycles of 5 h each. (Conditions: [NaAc] = 7.5 mM, [NH3/NH4+] = 2.2 mM as N, [Cl] = 4.2 mM, and flow rate = 70 ml min–1); b comparison in water flux (Jw) and RSF between the pristine membrane and the 5-cycle used membrane using deionised water as feed solution and 1 M NaCl as draw solution. The inset figure shows the reverse salt flux from the two membranes (error bars represent standard deviation from two independent replicates); c SEM images showing the surface morphology of the selective layer on the pristine membranes; d SEM images showing the surface morphology of the selective layer on the 5-cycle used membrane; e the rejection of sodium acetate, ammonia, and chloride by the FO membrane using 1 M KOH as draw solution (conditions: [Sodium acetate] = 7.5 mM, [Ammonia] = 2.2 mM as N, [Chloride] = 4.2 mM, and flow rate = 70 ml min–1); f J–V curves for 1 M KOH and 1 M KOH mixed with different impurities including sodium acetate, ammonia, and chloride (error bars represent standard deviation from three independent replicates). Source data are provided as a Source Data file.

Since impurities in the wastewater effluent may permeate through the FO membrane and thus affect electrolysis, we examined the rejection of common impurities in the wastewater effluent by the FO membrane, including NaAc, NH3/NH4+, and chloride (Fig. 2e). The rejection rates of NaAc, NH3/NH4+, and chloride remained stable throughout the five cycles at about 85%, 63%, and 98%, respectively. The lower rejection of NH3/NH4+ occurred as the TFC-FO membrane surface is negatively charged, which allows anions to be intercepted more readily than cations or unionised NH3 which is the dominant form of NH3/NH4+ at high pH. The rejection of additional common impurities found in wastewater and varied pH levels was also examined, with rejection rates exceeding 90% (Supplementary Figs. 5 and 6). The potential impacts to the electrolysis process from the permeated impurities were then investigated using a commercial 5-cell alkaline stack with nickel alloy-based electrodes by comparing the current density–voltage (J–V) curves generated from: (i) 1 M KOH, (ii‒iv) 1 M KOH mixed separately with NaAc, NH3/NH4+, and chloride at a concentration of 10 mM for studying their accumulation effect, respectively, or (v) a 1 M KOH mixture consisting of 1.1 mM of NaAc, 0.7 mM NH3/NH4+ as N, and 0.08 mM chloride observed in the permeate from the rejection test, as shown in Fig. 2f. All tested solutions exhibited a consistent behaviour in their J–V curve performances, suggesting that the presence of NaAc, NH3/NH4+, and chloride in KOH minimally impacted the current densities. We infer that the high concentration of KOH, sustaining a high pH (>8), mitigated the negative effects of NaAc and NH3/NH4+ and suppressed side reactions such as chlorine evolution31,39. Therefore, the above results of the high and constant water flux, the intact FO membrane, and the minor impact of impurities permeated from the FO membranes on electrolysis suggested using KOH as the draw solution in the FO process to extract water from wastewater effluent is feasible.

Integrating FO with AWE

A water-hydrogen balance model was established to quantify and balance the FO and AWE units in the FOWSAWE system, as shown in Fig. 3a, with the objective of continuous operation to effectively produce H2 from wastewater effluent. In the integrated system, clean water is first extracted from the wastewater effluent by the FO process using KOH as the draw solution and then split into H2 and oxygen (O2) by AWE using the 5-cell alkaline stack containing nickel alloy powder combined with nickel foam electrodes separated by polymer diaphragms (detailed setup is shown in the ‘Methods’ section). A sustainable operation of this system thus requires a dynamic equilibrium that enables the water production rate crossing the FO membrane (QFO) to match the water rate consumed by AWE (QAWE) as shown in Eq. 1, while maintaining a consistent concentration of KOH.

$${{Q}_{{{{{{\rm{FO}}}}}}}\,=\,S\Delta C\frac{{K}_{{{{{\rm{W}}}}}}I}{d}{{RT}}\,=\,Q}_{{{{{{\rm{AWE}}}}}}}\,=\,{i}_{{{{{{\rm{cell}}}}}}}\frac{{{{{{\rm{FE}}}}}} \, {{{\cdot} \, N}_{{{{{{\rm{cell}}}}}}}V}_{{{{{\rm{m}}}}}}}{2F}$$
(1)

QFO is a function of controllable parameters in the FO process including the membrane area (S, cm2) and the concentration gradient between draw solution and feed solution (ΔC, M)40. The membrane permeability coefficient (Kw, L atm–1 s–1 cm–1), when multiplied by the van’t Hoff factor of the feed solution (I), represents how easily water can be extracted through the membrane, remaining constant throughout the test. Other parameters, including the membrane thickness (d = 0.1 mm), the ideal gas constant (R = 0.0821 L atm K–1 mol–1), and temperature (T = 296 K), also remained constant during the test. QAWE is only controlled by the applied current of AWE (icell, A)41, as other parameters, including the Faradaic efficiency (FE), the number of cells constituting the electrolyser stack (Ncell = 5 for our setup), Vm (as the molar volume of H2O at 0.018 L mol–1 at 296 K of T and 1 atm), and Faraday’s constant (F = 96,485 C mol–1) are constant throughout the test. Therefore, through balancing QFO and QAWE, a linear correlation was established to describe the specific normalised current of the FOWSAWE system (Ji, A cm−2), which is defined as the required current of this integrated system for handling the permeated water per area of FO membranes (icellS–1), changed with ΔC as shown in Eq. 2.

$${J}_{i}\,=\,\frac{{i}_{{{{{{\rm{cell}}}}}}}}{S}\,=\,\left(\frac{{K}_{{{{{\rm{w}}}}}}{\it{I}}}{d}{RT}\frac{2F}{{{{{{{{\rm{F}}}}}} \, {{{{{\rm{E}}}}}}\,N}}_{{{{{{\rm{cell}}}}}}}{V}_{{{{{\rm{m}}}}}}}\right)\Delta C\,=\,\varPhi \cdot \Delta C$$
(2)

where Φ is the H2 production potential (L A mol–1 cm–2), determined by the configurations of the FO membranes and AWE, types of feed and draw solutions, and operational conditions. H2 production potential (Φ) was calculated by substituting the values of Kw × I, d, R, T, FE, Ncell, and Vm into Eq. 2, and Kw × I was obtained experimentally by measuring QFO under given conditions of S and ΔC in an independent FO module using Eq. 1, whereas FE was calculated by measuring the H2 production rate and purity at a given icell of the AWE module (detailed in the ‘Methods’ section). In this study, Φ values for feeding deionised water and the wastewater effluent collected from a wastewater treatment plant in Hong Kong (HK-WWE1) to the FOWSAWE system were calculated as 1.55 and 0.95 A mol–1 cm–2, respectively. The lower Φ for wastewater effluent was attributed to impurities in the wastewater effluent reducing Kw × I. The obtained Φ values were then used to generate the relationship between Ji and ΔC when reaching a dynamic equilibrium for the FO and AWE units in the FOWSAWE system, as shown in Fig. 3b. Therefore, to maintain ΔC at 1 M, Ji was calculated as 1.55 and 0.95 A cm–2 for deionised water and HK-WWE1, respectively21.

Fig. 3: Integrating the FO processes with alkaline water electrolysis (AWE).
figure 3

a Schematics showing a dynamic equilibrium to balance the water production rate crossing the FO membrane (QFO) and the water consumption rate by AWE (QAWE) in the FOWSAWE system; b the specific normalised current (icell/S) as a function of the concentration gradient (ΔC) to reach the equilibrium in the FOWSAWE system fed with deionised water and wastewater effluent. Data can be reproduced using Eq. 2; c the water flux and ΔC of the FOWSAWE system during 2-cycle operation. The vertical dashed line represents the transition between the first cycle and second cycle; d the H2 production rate and H2 purity for using deionised water and wastewater effluent as the feed of the FOWSAWE system (error bars represent standard deviation from three independent replicates); e the resulting voltage during the operation of the FOWSAWE system. The vertical dashed line represents the transition between the first cycle and the second cycle (conditions: [KOH] = 1 M, S = 1 cm2, icell = 1.55 A for deionised water and 0.95 A for wastewater effluent (HK-WWE1)); f the water flux, voltage, and ΔC during the 168-h continuous operation of the integrated FOWSAWE system (conditions: [KOH] = 1 M, S = 1 cm2, and icell = 0.90 A using the HK-WWE-2). Source data are provided as a Source Data file.

The two setups of FO and AWE were then experimentally integrated using a 1 cm2 FO membrane and applying an icell of AWE of 1.55 and 0.95 A for deionised water and HK-WWE1 according to their Ji values, respectively (integrated process shown in Supplementary Fig. 17). As shown in Fig. 3c, d, the continuous operation of this integrated system over two cycles of 5 h each, demonstrated a stable water flux crossing the FO membrane, constant ΔC, and a stable H2 production rate when fed with either deionised water or secondary wastewater treated effluent. In addition, the molar ratio of the H2 generation rate to QFO was close to one after the two test cycles (Supplementary Fig. 7), indicating that nearly all the water produced from FO was consumed by AWE. These observations indicate a successful integration of FO and AWE processes and validate our established dynamic equilibrium for the FOWSAWE system. Using wastewater effluent as the feed resulted in a 38% decrease in both QFO and H2 production rate compared to feeding deionised water, which aligns with the decrease observed in the value of Kw × I from wastewater effluent. This indicates that these impurities mainly affect the capacity of the water produced from FO, and the ability of the FOWSAWE system to produce H2 relies on this water production capacity. Nevertheless, using wastewater effluent as the feed did not compromise the H2 purity, as evidenced by the comparable H2 percentage observed in samples produced using both deionised water and wastewater effluent, as shown in Fig. 3d. Additionally, the stability of H2 production was not affected either, as the FOWSAWE system operated at a near-constant voltage of 1.79 ± 0.01 V and maintained a Faradaic efficiency of over 99% throughout two cycles of 5 h each (Fig. 3e), indicating that there were no side reactions caused by impurities crossing the FO membranes or accumulation of undesired impurities.

A continuous 168-h operation of the FOWSAWE system was conducted to assess its long-term stability under consistent conditions using a wastewater effluent sample collected from a second wastewater treatment plant in Hong Kong (HK-WWE2), and the result is shown in Fig. 3f. The water flux decreased by ~12% from 15.6 to 13.7 LHM, whereas the voltage increased by 4% during the initial 24 h, starting from 1.75 V and maintaining at 1.82 V. In addition, the system sustained a ΔC consistently at around 1 M during the entire 168-h testing period. The 12% reduced water flux after the long-term operation was attributed to fouling from organic matter in the wastewater42, because the ratio of C to O elements on the membrane surface was reduced by ~13%, and no degradation of integrity for both the selective and support layers of the FO membrane was observed in SEM coupled with Energy Dispersive X-ray (Supplementary Table 3 and Fig. 8, respectively). FO membrane fouling was shown to be largely reversible, unlike the often irreversible fouling challenges faced in RO43, which means that the reduced water flux in our system can be easily recovered by backwashing or chemical washing. Notably, the H2 gas purity remained stably high at over 99% throughout the entire long-term operation (Supplementary Fig. 9). These results demonstrated the operational stability of the FOWSAWE system throughout the 168-h testing period. In addition, as the FOWSAWE system relies on the water flux to generate H2, we tested more wastewater samples from the southern and northeastern regions of China, with their composition and concentrations detailed in Supplementary Table 4. The results show that our system exhibited a constant water flux, voltage, and ΔC for various impurities and pH values from different wastewater samples (Supplementary Figs. 1012). Despite the varied Kw × I caused by different impurities, the resulting H2 production rates were consistent and remained within a range of 5% (Supplementary Fig. 11d). These results validate the stability and adaptability of our system for producing H2 under varying wastewater conditions.

H2 production and energy efficiency of the FOWSAWE system

The H2 production and energy efficiency of the FOWSAWE system showed superior performance compared with two other membrane-based P2H systems for seawater purification integrated with electrolytic water splitting: (i) the seawater electrolysis system (SES) using hydrophobic PTFE membranes with 30% KOH as a self-dampening electrolyte (SDE), and (ii) the FOWS employing cellulose triacetate (CTA) membranes with 0.8 M sodium phosphate as the electrolyte21,22. The H2 produced in the three systems was compared by normalising the H2 production rate over the area of water-producing membranes, as shown in Fig. 4a. The FOWSAWE system produced the highest H2 rate at 448 Nm3 day–1 m2 of TFC-FO membrane, which is 102 and 14 times higher than those of SES and FOWS, respectively. This significant improvement in H2 production compared with SES is primarily due to the higher Φ provided by FO membranes in producing more water. Unlike SES using hydrophobic PTFE membranes, the TFC-FO membrane is hydrophilic and thus offers higher Kw to allow water to permeate. This is verified by the 23‒32 times higher Ji of the TFC-FO membrane to reach equilibrium than the PTFE membrane at the same values of S, ΔC, and using identical AWE setups (Supplementary Fig. 13). Besides, PTFE membranes face wetting issues during operation, which reduces the ability to reject impurities as water penetrates the pores44,45. The enhanced H2 production compared to FOWS is mainly attributed to the 5× higher ΔC between wastewater effluent and 1 M KOH compared to the 0.2 M ΔC between seawater and 0.8 M sodium phosphate, enhancing the driving force for producing water. The H2 flux comparison along with the water-hydrogen model suggests the water production rate dominates in determining the H2 flux in a membrane-electrolysis system, highlighting the importance of optimising both the membrane type and the feed water source. Moreover, high water production rates offer additional benefits of requiring fewer membranes and associated equipment, thereby reducing space and capital costs which are particularly important considerations for scaling up the system.

Fig. 4: H2 production and energy efficiency of the FOWSAWE system.
figure 4

a The comparison in H2 flux among three membrane-based P2H systems (error bar represents the standard deviation from three independent replicates); b the comparison in specific energy consumption (SEC) among three membrane-based P2H systems. The orange region represents the SEC range typical for direct wastewater electrolysis. The green region represents the SEC range for industrial alkaline water electrolysis; c H2 flux and SEC of the FOWSAWE system changed with KOH temperatures. Source data are provided as a Source Data file.

The FOWSAWE system exhibits low energy consumption, as shown in Fig. 4b, where the SEC of the three systems is compared in addition to direct wastewater electrolysis. The FOWSAWE system requires the lowest SEC at 4.43 kWh Nm–3 at an icell of 0.95 A using wastewater effluent as feed. This SEC is comparable to commercial alkaline electrolysis systems that use deionised water and is 10%, 34%, and 84% lower than SES, FOWS, and direct electrolysis of wastewater, respectively46. The lower SEC highlights the importance of preventing undesired impurities from electrolysis and using a pH-tolerant membrane to enable the use of KOH as an electrolyte as it has higher ionic conductivity for more efficient electron transfer. Such excellent energy efficiency is also applicable to other commercial AWE configurations, if the applied current matches the water-hydrogen equilibrium, making the FOWSAWE system easily adaptable and scalable to meet varying market demands. Therefore, the hydrophilic property of TFC-FO membranes, the higher ΔC resulting from wastewater effluent usage instead of seawater, and the use of an optimal electrolyte (i.e. KOH) all contribute to a high H2 flux and energy-efficient P2H conversion.

In addition, electrolysis is an exothermic process that generates heat, so capturing and utilising waste heat during AWE operations is critical in achieving the energy-efficient operation of the system. By simulating the capture and utilisation of the waste heat during AWE operations to heat up the KOH draw solute temperature to 40 °C, the FOWSAWE system shows an increase of H2 flux by 11% and a decrease of SEC from 4.43 to 3.96 kWh Nm–3 (Fig. 4c and detailed calculations provided in Supplementary Note 1). This brings us closer to the target of 3.75 kWh Nm–3 proposed by the International Renewable Energy Agency47. The enhanced H2 flux is mainly due to the increased water production at higher temperatures, indicated by Eq.148, while the reduced SEC is attributed to the increased KOH ionic conductivity reducing the overall resistance of the cell and enabling more efficient electron transfer (Supplementary Fig. 14). These results also suggest that the FOWSAWE system can perform better in hot regions where the wastewater has temperatures of up to 35 °C and can potentially heat the draw solutions during membrane operational processes28, or in areas with abundant solar energy that can be used for heating.

Implications for H2 production using wastewater effluent

This study demonstrated the use of municipal wastewater effluent by a FOWSAWE system for fast and energy-efficient green H2 generation to address the large-scale H2 production need associated with potential water constraints. The FOWSAWE system exhibits stable and continuous H2 production at the highest yields of H2 to date (448 Nm3 day–1 m–2) using alternative water resources achieving a high H2 purity of >99% and low SEC of 4.43 kWh m–3 during the entire testing period of over 10 h. In addition, the FOWSAWE system demonstrated long-term stability by being operated continuously for 168 h using real wastewater effluent and proved its capability and adaptability in producing H2 across diverse wastewater conditions found in different regions.

Using wastewater effluent is crucial for sustainable H2 production in regions where seawater is unavailable or freshwater resources are scarce, especially as H2 projects are rapidly expanding amid the foreseeable intensified worldwide water stress. The modular FO and AWE system along with the established water-hydrogen balance model allow the FOWSAWE system to operate with different influent water quality at different scales, ensuring an easy yet versatile approach for sustainable P2H conversion from the household to the city scale. The integration of TFC-FO with electrolysis can reduce the capital costs of water treatment by up to 46% compared to conventional RO and FO–RO processes49, providing a strong economic incentive for FOWSAWE adoption. Addressing pressing global challenges such as water scarcity, climate change, and energy insecurity requires urgent action. Existing technologies, such as the FO and AWE, can substantially impact on solving these challenges if applied and integrated more effectively. The FOWSAWE system exemplifies leveraging synergistic technologies to rapidly develop economical, efficient, and sustainable solutions for interconnected environmental issues.

In addition to the H2 production market for industrial use and energy storage, the FOWSAWE system provides advantages to wastewater treatment plants and many industries, as it serves as a tool for water reuse. The system has the potential to reduce the treatment load and wastewater discharge while simultaneously generating onsite energy, and mitigating environmental impacts50. It is estimated that an onsite FOWSAWE station with a capacity of 5‒6 MW can produce O2 at ~20,000 kg day–1, which can supply the aerobic processes of a wastewater treatment plant in treating 50,000 m3 day–1 of wastewater (calculation shown in Supplementary Note 2)51,52 or support high-density in-land and offshore aquaculture53,54. Moreover, fuel cells that use H2 to generate electricity also produce high-purity water as a byproduct, which can be supplied to industries that require it, e.g. semiconductor and pharmaceutical industries.

Methods

Chemicals

Potassium hydroxide (KOH, Scharlau, 85.0–100.5%), sodium bicarbonate (NaHCO3, Sigma-Aldrich, 99.5–100.5%), potassium pyrophosphate (K4P2O7, Macklin, 99%), sodium chloride (NaCl, Sigma-Aldrich, ≥99%)), ammonium chloride (NH4Cl, Sigma-Aldrich, ≥99.5%), and sodium acetate (CH3COONa, Sigma Aldrich, ≥99%). The stock solutions were prepared by dissolving these chemicals in deionised water (18.2 MΩ cm) produced by a water purification system (Millipore, USA). The simulated wastewater effluent was prepared by adding 7.5 mM of sodium acetate, 2.7 mM of NH3/NH4+, and 4.2 mM of chloride into deionised water. Two wastewater effluent samples were collected from two different treatment plants in Hong Kong SAR labelled as HK-WWE1 and HK-WWE2. Additionally, one wastewater effluent sample was obtained from Guangdong Province, China, designated as GD-WWE, and another from Northeast China, referred to as NC-WWE. All the samples were filtered with high-pressure filtration equipment using cellulose membrane filters (pore size: 0.45 µm) and stored at 4 °C. The quality of the wastewater effluent samples used in this study are presented in the Supplementary Table 4.

FO to extract clean water

The experiments to produce clean water from FO processes were conducted in an independent FO module as shown in Supplementary Fig. 15. The FO module consists of an FO cell with two chambers with an area of 12 cm2 and a depth of 0.3 cm separated by a single flat FO membrane sheet (051303, Porifera). The feed solution chamber was connected to a feed solution tank with a volume of 500 mL while another was connected to a draw solution tank with a volume of 200 mL. The feed solution was recirculated from the feed tank to the FO feed solution chamber by a peristaltic pump at a flow rate of 70 mL min–1. On the other side, the draw solution was recirculated from the draw solution tank to the FO draw solution chamber at the same flow rate. The water flux (JW, LHM) was gravimetrically measured by the loss of water weight in the feed tank per unit of time using an electronic balance (FX-3000GD, A&D Instruments) divided by the membrane area (Eq. 3).

$${J}_{{{{{\rm{W}}}}}}\left({{{{{\rm{LHM}}}}}}\right)\,=\,\frac{\Delta M}{\rho \, {\cdot} \, S \, {\cdot} \, \Delta t}$$
(3)

where ΔM is the water weight change during the test (g), ρ is the water density of 1 kg L–1, S is the membrane area (m2), and Δt is the time interval of recording water weight (h). The RSF was determined by measuring the potassium ion concentration via an Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES, 725-ES, Varian). The RSF (JS, GHM) was obtained by the changes in KOH concentration to the feed solution, as shown in Eq. 4.

$${{{{{\rm{RSF}}}}}}\left({{{{{\rm{GHM}}}}}}\right)\,=\,\frac{{V}_{t}\cdot{C}_{t}\,-\,{V}_{0}\cdot{C}_{0}}{{S}{\cdot}\Delta t}$$
(4)

where V0 and Vt represent the volumes of the feed solution before and after testing, while C0 and Ct represent the concentrations of KOH in the feed solution before and after the tests, respectively. The conductivity and the pH of the feed solution were monitored using a multiparameter benchtop metre (Multi 9630 IDS, WTW inoLab). The rejection of impurities by the FO membrane was calculated using Eq. 5:

$${{{{{\rm{Rejection}}}}}} \, \left(\%\right)\,=\,\left(1\,-\,\frac{{C}_{{{{{\rm{P}}}}}}}{{C}_{{{{{\rm{f}}}}}}}\right)\,\times\,100$$
(5)

where Cp and Cf represent the concentrations of the permeated impurities including sodium acetate, NH3/NH4+, or chloride through FO membrane and their initial feed concentrations, respectively. The concentrations of sodium acetate and NH3/NH4+ were measured by a total organic carbon analyser coupled with a total nitrogen measurement (TOC-L analyser with TNM-L, Shimadzu). The concentrations of NH3/NH4+ in the wastewater effluent samples were measured by spectrophotometric method. The concentrations of chloride were quantified using ion chromatography (IC, 940 Professional IC Vario, Metrohm). The membrane before and after use was characterised by SEM (JSM-6700F, JEOL and MAIA3, Tescan) and FTIR (Vertex 70, Bruker).

Water electrolysis system to produce hydrogen

The experiments to produce H2 were conducted in an independent AWE module, as shown in Supplementary Fig. 16. The AWE module consists of a 5-cell alkaline stack (LBE-5SC, Light Bridge Inc.) that utilises bipolar electrodes separated by polymer diaphragms, an electrolyte supply tank, and a gas separator for collecting H2 and O2. The electrodes, that are composed of nickel alloy powder combined with nickel foam, have a thickness of 0.8 mm, a diameter of 44 mm, an area of 15.2 cm2, and a mass loading of 74.3 mg cm–2. Meanwhile, the polymer separators have a thickness of 100–130 µm, a diameter of 51 mm, and an area of 15.2 cm2. The lower potential cut-off was determined to be 1.5 V per cell. The alkaline stack was supplied with different electrolytes using a peristaltic pump. The J–V curves of different electrolytes were collected using a DC power supply (DP3030, MESTEK). The impact of impurities on water electrolysis was determined by adding the target compounds in the electrolyte to obtain J–V curves. The impact of temperature on water electrolysis was obtained by regulating the electrolyte temperature using a water bath (HH-1, KOY) in the AWE module for generating J–V curves.

Integrating FO and AWE to make the FOWSAWE system

The process design of the FOWSAWE system is shown in Supplementary Fig. 17. Clean water was first extracted from the feed wastewater effluent tank via the FO process with the same setup as the independent FO module described earlier except the membrane area was 1 cm2. The extracted clean water diluted the KOH draw solution whose concentration was then recovered by splitting the water in the AWE using the diluted KOH as the electrolyte. The AWE outflow consisted of two KOH streams, one mixed with H2 and the other mixed with O2. The H2 and O2 were then separated from the KOH streams using a gravity-based gas–liquid separator, and the KOH stream free of gases flowed back to the draw solution tank. The KOH concentration was continuously monitored by analysing the change in the conductivity of the draw solution and the change in the pH of feed the wastewater effluent. ΔC was determined by subtracting the molar concentration of all impurities in the feed tank (Σ[impurities]feed) as listed in Supplementary Table 4 and the molar concentration of KOH in the feed tank due to RSF ([KOH]feed) from the molar concentration of recovered KOH in the draw solution tank ([KOH]recovered) as shown in Eq. 6:

$$\Delta C\,=\,{\left[{{{{{\rm{KOH}}}}}}\right]}_{{{{{{\rm{recovered}}}}}}}\,-\,\Sigma {\left[{{{{{\rm{impurities}}}}}}\right]}_{{{{{{\rm{feed}}}}}}}\,-\,{\left[{{{{{\rm{KOH}}}}}}\right]}_{{{{{{\rm{feed}}}}}}}$$
(6)

The separated H2 was collected by draining the water downwards in an inverted measuring cylinder, and the H2 production rate was determined by the water drainage volume over pre-determined time intervals. The H2 flux was then calculated by dividing the obtained H2 production rate by the FO membrane areas. The purity of the collected H2 was analysed by gas chromatography (990 Micro GC System, Agilent) equipped with a thermal conductivity detector. The obtained H2 production rates and H2 purity were used to determine the Faradaic efficiency (FE) of the system by dividing the experimentally measured H2 production rate (\({r}_{{{{{\rm{{H}}}}}_{2}}}\)) by the theoretical H2 production rate (\({r}_{{{{{\rm{{H}}}}}_{2}},{{{{{\rm{ideal}}}}}}}\)) (Eq. 7).

$${{{{{{\rm{FE}}}}}}}_{{{{{\rm{{H}}}}}_{2}}}\,=\,\frac{{r}_{{{{{\rm{{H}}}}}_{2}}}}{{r}_{{{{{\rm{{H}}}}}_{2}},{{{{{\rm{ideal}}}}}}}}\,=\,\frac{{r}_{{{{{\rm{{H}}}}}_{2}}}}{\frac{i}{2F}\,\times\,\frac{{RT}}{{P}_{0}}}$$
(7)

where P0 is atmospheric pressure (101 kPa), and T is the operating temperature (296 K). The SEC of the FOWSAWE system (kWh Nm–3) was calculated using Eq. 8.

$${{{{{\rm{SEC}}}}}}\,=\,\frac{{i}_{{{{{{\rm{cell}}}}}}}\,\times\,U}{{r}_{{{{{\rm{{H}}}}}_{2}}}}$$
(8)

where U is the resulting voltage (V) obtained. The icell value was 1.55 A when deionised water was used as the feed source, 0.95 A when HK-WWE-1 was used as the feed source, and 0.90 A when HK-WWE-2 was used as the feed source during the long-term test.