Introduction

Materials exhibiting a positive temperature coefficient (PTC) effect of resistivity are used in breakers to protect electronic circuits. The PTC effect implies that resistivity increases with rising temperature. Impurity-doped BaTiO3 exhibits the PTC effect.1, 2, 3 However, BaTiO3-based materials exhibit an NTC (negative temperature coefficient) effect immediately after the PTC effect. The NTC effect implies that resistivity decreases with rising temperature. It is thought that materials exhibiting an NTC effect are inappropriate for use in electronic circuit protection.

Conductive polymer composites4, 5, 6, 7, 8, 9 with a conductive filler also exhibit the PTC effect. These composites are conventionally fabricated by filling carbon black (CB), metal powder or carbon nanotubes into a polymer matrix. Flexibility and processability are the advantages of these composites. To use conductive polymer composites in the protection of electronic circuits, both low resistivity at room temperature (ρL) and high resistivity at high temperature (>100 °C) are essential. In addition, it is essential that the NTC effect does not occur immediately after the PTC effect. To fabricate conductive polymer composites with these properties, it is necessary to clarify the physical mechanisms and their relation to the electrical properties of composites.

The ρL of conductive polymer composites filled with metal is 10−2 Ωcm.5 Percolation conduction, tunneling conduction and hopping conduction are considered as the electrical conduction mechanisms of conductive polymer composites. In particular, the low resistivity of conductive polymer composites with a large amount of conductive filler is explained by the percolation theory.8, 10, 11, 12, 13, 14, 15, 16 Nakamura et al.16 reported that the change in ρL with increasing conductive filler content has two transition points and revealed that the conduction mechanism changes from a non-ohmic behavior to an ohmic behavior once the conductive filler content reaches the second transition point.16 They revealed that the critical filler content (percolation threshold), which forms a conductive path, is the second transition point.16

On the other hand, the resistivity at high temperature (>100 °C) of conductive polymer composites reaches 105 Ωcm even with a large amount of conductive filler.5 In particular, resistivity increases significantly after melting of the polymer.4, 5

In a previous paper, we suggested that conductive fillers are localized in the amorphous matrix of the polymer.4 Thus, we assume that an investigation of the relationship between the electrical properties of composites and the crystallinity of the polymer is important.

In this paper, we discuss the effect of cooling rate after polymer melting on the electrical properties of HDPE/Ni conductive polymer composites prepared by the melt-blending method. We demonstrate that the ρL of the slowly cooled sample is lower than that of the quenched sample, because of increased crystallinity of the HDPE. Furthermore, we demonstrate that the PTC effect of the HDPE/Ni conductive polymer composites with a low Ni content occurs from the slight cubical expansion of the HDPE, whereas the PTC effect of the HDPE/Ni conductive polymer composites with a high Ni content occurs from both the drastic cubical expansion of the HDPE and the diffusion of localized Ni particles into the amorphous matrix of the HDPE, because of the change from a crystalline matrix to an amorphous matrix with the melting of the HDPE.

Experimental procedure

Materials

HDPE was used as a base polymer for conductive polymer composites, specifically, HJ560 manufactured by Japan Polyethylene (Tokyo, Japan). Its density was 0.964 g cm−3; its melting point was 135 °C; and its melt flow rate (temperature 190 °C, force 2160 g) was 7 g/10 min. Ni particles manufactured by Inco (Toronto, Canada) were used as the conductive filler of the conductive polymer composites. Its density was 8.91 g cm−3, its particle size was 2.5 μm and its resistivity was 7 × 10−5 Ωcm.

Sample preparation

HDPE pellets and Ni particles were melt blended at 200 °C and at 60 r.p.m. for 15 min, using a plastic mixing apparatus (Toyo Seiki 4M150; Toyo Seiki, Tokyo, Japan). The HDPE/Ni blend was inserted between the two Fe boards (150 mm × 150 mm × 2.2 mmt) of a metallic mold and molded to a 1 mm-thick board (sample) using the hot-press method. Prehot press was performed at 2.5 MPa and at 200 °C for 3 min, and hot press was performed at 5 MPa and 200 °C for 4 min. The sample in the metallic mold, after application of the hot press, was cooled in ice water (quench) or in air (slow cooling). Figure 1 depicts the sample temperature as a function of cooling time. The cooling time from 200 to 25 °C (R.T.) for the quench method was 10 min and that of the slow cooling method was 45 min.

Figure 1
figure 1

Change of sample temperature (T) as a function of cooling time (t). •: Quenching (in ice water). : Slow cooling (in air).

Characterization of the conductive polymer composite

The ρL was measured by the four-point probe method. The probe distance was 5 mm, and the applied current for measurements was 100 μA. The PTC effect was evaluated by measuring resistance using the two-terminal method while the sample was being heated in an oven at a rate of 1 °C min−1. In the two-terminal method, resistivity ρ was calculated using equation ρ=RS/d from the measured values of resistance R, sample area S and sample thickness d. Sample area was 1 cm2 and sample thickness was approximately 0.5 mm. To measure the resistance (resistivity) of the sample by the two-terminal method, Ni foil was heat sealed at 1 MPa and at 200 °C for 5 min to form electrodes on both sides of the sample. The quenched sample, after the hot-press procedure, was again quenched after Ni foil lamination, and the slowly cooled sample, after the hot-press procedure, was again cooled slowly after Ni foil lamination. The cooling method (quenching or slow cooling) of the sample after Ni foil lamination was the same as described in subsection ‘Sample preparation’. The applied current for measurements was 100 μA (when resistance is lower than 5 kΩ), 12 μA (when the resistance range is 5–50 kΩ) and 1.2 μA (when resistance is larger than 50 kΩ). For the PTC effect of samples, we defined the inflection-point temperature of the PTC curve as the transition temperature. The crystallinity of HDPE was evaluated from the X-ray diffraction (XRD) spectrum of 30 kV–15 mA CuKα radiation, using an XRD apparatus (Rigaku Mini Flex II; Rigaku, Tokyo, Japan).

Results and Discussion

Relationship between cooling rate after polymer melting and crystallinity of the HDPE

Figure 2 plots the XRD spectra of the quenched pure HDPE board (Ni content CNi=0 wt.%) and the slowly cooled pure HDPE board (CNi=0 wt.%). Sharp peaks from crystalline phases were observed in both the XRD spectrum of the quenched HDPE and that of the slowly cooled HDPE. To evaluate the crystallinity of the HDPE, the background and CuKα2 peaks of the XRD spectrum (Figure 2) were separated by the Sonneveld–Visser method17 and the Rachinger method.18 The crystallinity of the quenched HDPE was 60% and that of the slowly cooled HDPE was 68%. It was assumed that this difference was the result of the difference between cooling rate with the quench method and that with the slow-cooling method from the polymer melt.

Figure 2
figure 2

Typical XRD spectra of pure HDPE boards (Ni content=0 wt.%). Solid line: Quenched HDPE. Dashed line: Slowly cooled HDPE.

We also investigated the crystallinity of the HDPE filled with various concentrations of Ni particles. Figure 3 illustrates the crystallinity of the HDPE in the quenched sample and that in the slowly cooled sample as a function of CNi. The crystallinity of HDPE in both quenched samples and slowly cooled samples decreased with increasing CNi. Ni particles interfered with the crystallization of HDPE.

Figure 3
figure 3

The change in crystallinity of HDPE as a function of Ni content (CNi). : Quenched HDPE/Ni composites. : Slowly cooled HDPE/Ni composites.

Resistivity of HDPE/Ni conductive polymer composites at room temperature as a function of Ni content

Figure 4 presents the ρL value of the quenched sample and that of the slowly cooled sample as a function of CNi. The ρL of the slowly cooled sample was lower than that of the quenched sample. In a previous paper,4 we suggested that CB particles in HDPE/CB conductive polymer composites are localized in the amorphous matrix of the HDPE. On the basis of this suggestion, we assume that Ni particles in HDPE/Ni conductive polymer composites are localized into the amorphous matrix of HDPE. The conductive paths are likely formed by these localized Ni particles. Figures 5a–d schematically illustrate the conductive path connection of the HDPE/Ni conductive polymer composite. Both crystallite size and thickness of the lamella are approximately tens of nanometers.19 On the other hand, the size of the average Ni particle is 2.5 μm. Therefore, it is thought that Ni particles are not in the crystalline matrix of the HDPE, but in the amorphous matrix of the HDPE. As indicated in Figures 5a and b, the conductive path connection is facilitated by increased crystallinity of the HDPE. Consequently, it is suggested that ρL decreases with an increase in crystallinity of HDPE. Therefore, ρL of the slowly cooled sample is lower than that of the quenched sample.

Figure 4
figure 4

The change in ρL of HDPE/Ni composites as a function of Ni content (CNi). : Quenched HDPE/Ni composites. : Slowly cooled HDPE/Ni composites.

Figure 5
figure 5

Schematic illustrations of the conductive path connection of HDPE/Ni composites. (a) Quenched HDPE/Ni composite with a small number of Ni particles. (b) Slowly cooled HDPE/Ni composite with a small number of Ni particles. (c) Quenched HDPE/Ni composite with a large number of Ni particles. (d) Slowly cooled HDPE/Ni composite with a large number of Ni particles.

Figure 4 demonstrates that the slope of ρL change in the quenched sample is larger than that of the slowly cooled sample. In the slowly cooled sample, many conductive paths are formed, even with low CNi (70 wt.%), because the crystallinity of HDPE is high. Therefore, conductive paths grow less rapidly with increasing CNi, and the slope of ρL change in the slowly cooled samples is small. On the other hand, quenched samples have few conductive paths when the CNi is low (70 wt.%) because the crystallinity of HDPE in quenched samples is low. It is expected that conductive paths would grow rapidly with increasing CNi. Therefore, the slope of ρL change in the quenched samples is large.

Figure 4 indicates that the difference between the ρL value of the quenched sample and that of the slowly cooled sample decreased with increasing CNi. When CNi is high, it is assumed from Figures 5c and d that conductive paths are formed effectively, even with the low crystallinity of HDPE.

PTC effects of HDPE/Ni conductive polymer composites

Figure 6 plots the PTC curves of the quenched sample and of the slowly cooled sample as a function of CNi (70, 80, 90 and 95 wt.%). When CNi<90 wt.%, transition temperature decreases with decreasing CNi. However, the transition temperatures of CNi=90 wt.% samples are consistent with those of CNi=95 wt.% samples.

Figure 6
figure 6

PTC curves of HDPE/Ni composites at various Ni contents (CNi). ♦: CNi=70 wt.% (quench). : CNi=70 wt.% (slow cooling). : CNi=80 wt.% (quench). : CNi=80 wt.% (slow cooling). : CNi=90 wt.% (quench). : CNi=90 wt.% (slow cooling). ▪: CNi=95 wt.% (quench). □: CNi=95 wt.% (slow cooling).

In a previous paper,4 we investigated the PTC effect of the crystalline polymer/CB (for example, HDPE/CB, polypropylene/CB and syndiotactic-polystyrene/CB) conductive polymer composites and found that transition temperature corresponds to the melting point of the polymer. Consequently, it is thought that the PTC effect of HDPE/Ni conductive polymer composites occurs from melting HDPE. Conductive path disconnection by both the diffusion of the localized Ni particles in the amorphous matrix of HDPE because of the change from a crystalline matrix to an amorphous matrix and the drastic cubical expansion of HDPE20 are considered to be the mechanisms of the PTC effect observed during HDPE melt. In addition, the volume of HDPE expands slightly, even with temperatures below the melting point.20 This might contribute to the disconnection of the conductive paths. Thus, it is reasonable to consider that the origins of the PTC effect in HDPE/Ni conductive polymer composites arise both from the melting of HDPE and from the cubical expansion of HDPE.

It is assumed that the connection of Ni particles becomes weaker with decreasing CNi. Therefore, lower CNi leads to the disconnection of conductive paths by smaller cubical expansions of the HDPE, and the transition temperature decreases with decreasing CNi when CNi<90 wt.%. In contrast, when CNi90 wt.%, it is assumed that the conductive paths are not disconnected by the slight cubical expansion of the HDPE, because the conductive paths are more robust, formed by many Ni particles (see Figures 5c and d). Therefore, conductive paths are disconnected by the melting of HDPE. Thus, the transition temperatures of CNi=90 wt.% samples are consistent with those of CNi=95 wt.% samples. It is clear from the result that the transition temperatures of samples at CNi=90 and 95 wt.% are equal to the melting point of HDPE (see Figure 6).

Figure 6 demonstrates that the PTC curve of the slowly cooled sample is consistent with that of the quenched sample when CNi=80, 90 and 95 wt.%. In contrast, the PTC curve of the slowly cooled sample is not consistent with that of the quenched sample when CNi=70 wt.%. We demonstrated in subsection ‘Resistivity of HDPE/Ni conductive polymer composites at room temperature as a function of Ni content’ that the localization of Ni particles decreases with decreasing crystallinity of HDPE. Therefore, we assume that the conductive paths of the quenched sample are more easily disconnected than those of the slowly cooled samples. Thus, the PTC curve of the slowly cooled sample is not consistent with that of the quenched sample when CNi=70 wt.%. Moreover, we assumed that the influence of the crystallinity of HDPE on the connection of conductive paths becomes smaller with increasing CNi (see Figures 5c and d). Therefore, the PTC curve of the slowly cooled sample is consistent with that of the quenched sample when CNi=80, 90 and 95 wt.%.

Figure 6 indicates that both the quenched sample and the slowly cooled sample at CNi=95 wt.% exhibit the NTC effect. This suggests that Ni particles reassemble with decreased viscoelasticity after HDPE melting.21

Conclusions

We investigated the effect of cooling rate after polymer melting on the electrical properties of HDPE/Ni conductive polymer composites prepared by the melt-blending method. It was assumed that conductive paths are formed by localized Ni particles in the amorphous matrix of HDPE. Conductive paths were formed effectively by increasing HDPE crystallinity. We demonstrated that HDPE/Ni conductive polymer composites with low ρL can be fabricated by slow cooling after polymer melting because the crystallinity of HDPE increases with slow cooling from the polymer melt. It was assumed that the PTC effect in HDPE/Ni conductive polymer composites occurs from cubical expansion of HDPE and diffusion of localized Ni particles into the amorphous matrix of the HDPE because of the change from crystalline to amorphous with the melting of the HDPE. The PTC effect of HDPE/Ni conductive polymer composites with a low Ni content results from the slight cubical expansion of HDPE, whereas the PTC effect of HDPE/Ni conductive polymer composites with a high Ni content results from both the drastic cubical expansion of HDPE and the diffusion of localized Ni particles in the amorphous matrix of HDPE, because of the change from a crystalline matrix to an amorphous matrix with HDPE melting.