Abstract
When two liquid drops touch, a microscopic connecting liquid bridge forms and rapidly grows as the two drops merge into one. Whereas coalescence has been thoroughly studied when drops coalesce in vacuum or air, many important situations involve coalescence in a dense surrounding fluid, such as oil coalescence in brine. Here we study the merging of gas bubbles and liquid drops in an external fluid. Our data indicate that the flows occur over much larger length scales in the outer fluid than inside the drops themselves. Thus, we find that the asymptotic early regime is always dominated by the viscosity of the drops, independent of the external fluid. A phase diagram showing the crossovers into the different possible late-time dynamics identifies a dimensionless number that signifies when the external viscosity can be important.
Similar content being viewed by others
Introduction
During coalescence, two drops merge via the formation of an infinitesimal liquid bridge between them, which then expands to the size of the drops. The dynamics is driven by the Laplace pressure, which initially is singular due to the infinite curvature of the liquid interface at the point of contact. This coalescence singularity has been studied in the situation where the two drops coalesce in vacuum or air1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18. These studies sought to understand the speed at which the neck radius, r(t), expands as a function of t, the time since initial contact. Different dynamic regimes have been identified. However, in many natural settings19,20,21 and industrial applications22,23,24, coalescence occurs inside a surrounding fluid that cannot simply be ignored.
One would, in general, expect that the addition of an external fluid would lead to an even more complex phase diagram with a variety of regimes where different forces, from flows external as well as internal to the drops, compete to determine the dynamics. Even without a significant external fluid, the dynamics of drop coalescence is complicated and subtle due to the many length scales over which flows can take place: the drop radius, A, the neck radius, r, the separation of the two drops at that radius, r2/A, and the curvature at the neck minimum for viscous drops, r3/A2 (refs 1, 4, 15, 18).
Some earlier experimental studies of two-fluid coalescence worked in a regime where the viscosity or density of the outer fluid was considered to be negligible for the dynamics25,26. One study that worked in the regime where the external viscosity was substantial27 reported that the larger of μin or μout (the viscosity inside or outside the drop, respectively) determines the coalescence rate when viscosity dominates over inertia. In contrast, a theory addressing the effect of an exterior fluid in the Stokes regime (where inertia can be completely neglected for the flows inside the drop) predicted that the outer fluid initially decreases the rate of neck expansion, dr(t)/dt, by a factor of 4, independent of the value of μout (ref. 4). This theory, however, does not address late times or the case where the outer fluid dominates the dynamics as in the coalescence of bubbles. (Moreover, it was recently shown15,18 that the Stokes description can only apply when both the neck radius and the inner viscosity are sufficiently large.) Finally, it was predicted that in the two-fluid case inertial forces are proportional to the sum28,29 of the inner and outer fluid densities.
Here, by identifying the different regimes of coalescence when an exterior fluid is present, we can sort out some of these different claims. In particular, we measure the scaling laws for r(t) in the case of two bubbles or drops merging in an outer fluid that is dominated by either viscous or inertial forces. We also determine the crossovers between the different dynamic regimes. Our results show a clean separation of regimes that delineate when the viscosity or inertia either inside of, or external to, the drops will dominate the dynamics. Our analysis shows that the length scales in the external fluid are much larger than those inside the drops when μout≫μin. This dramatically changes the competition between the different forces in the problem and leads to the appealing, although perhaps counter-intuitive, result that the inner fluid invariably dominates the asymptotic dynamics at small scales and early times. Finally, our work identifies a dimensionless number that indicates when the viscosity of the external fluid controls the dynamics.
Results
Experiment
In our experiments, we coalesce hemispherical drops (or bubbles) of radius A. We use combinations of water and glycerol to vary the viscosity of the drops. Salt is dissolved in the drops to make them electrically conductive. The drops or bubbles are submerged in silicone oils having a wide range of viscosity (0.49 mPa s<μout<29,000 mPa s) but little variation in density (761 kg m−3<ρout<976 kg m−3). The interfacial tension, γ, varies by less than a factor of 1.15 in the two-fluid experiments for a fixed inner fluid and by a factor of 1.35 for air bubbles in different silicone oils, allowing us to isolate the external viscosity. Additionally, by changing the glycerol and salt content of the inner fluid and by coalescing the drops in either silicone oil or air, we vary the surface tension between 23.5 and 82.5 mN m−1.
In the absence of an external fluid, the dynamics is determined solely by the dimensionless neck radius, r/A, and the dimensionless Ohnesorge number, Ohin=μin/, which is a ratio of viscous forces to inertial and surface tension forces. In that case, coalescence begins in the inertially limited viscous (ILV) regime where
where C0 is a prefactor of order unity15,18. In this regime, viscous stresses are dominant near the neck; however, the large inertia of the drops (which must be pulled together by the small forces at the neck) prevents the purely viscous (Stokes) theory from applying15,18. In our experiments, Ohin<1, so in the absence of an outer fluid, the drops would begin their coalescence in the ILV regime and transition to a regime dominated by inertia at late times. For the outer fluid, we define Ohout=μout/, which is varied from 0.0013 to 210 in our experiments.
We use an ultrafast electrical method12,13,14,15,18,30 to probe the neck radius, r(t). We complement the electrical measurements with high-speed imaging, which does not extend to early times due to the small neck height (~r2/A) and the high curvature at the neck minimum (~A2/r3). For bubble coalescence, measurements are obtained only from imaging.
Salt water drops coalescing in outer fluids
Figure 1a,b compares, at 1 ms after contact, salt water drops coalescing in silicone oils of viscosities varying by a factor of 100. The neck radii are essentially equal. Figure 1c shows that r(t) for salt water drops is independent of the outer viscosity, even when μout≈50μin.
All the data are consistent with r(t) ∝ t at early times, as in equation 1 describing drop coalescence in air: the dynamics is dominated by the inner fluid despite the much more viscous surroundings.
Coalescence of air bubbles in an outer fluid
To understand the role of the outer fluid, we study the coalescence of air bubbles to approximate the limit where the interior fluid has negligible viscosity and density. In this case, there is no resistance to tangential flow at the drop interface so that the outer fluid can escape radially without significant axial velocity gradients over the small length scale r2/A. Instead, the dominant gradients are in the radial direction over a length scale L≈r. The driving force is the average Laplace pressure in the neck region, ΔP≈γA/r2. (Derivations of these choices for L and ΔP are given in the Methods section.) With these choices for L and ΔP, we can estimate the velocity of the expanding bubble neck radius.
When the inner fluid can be completely neglected and the external fluid is viscous, the viscous stress, μout(∂u/∂x), can be estimated by μout(U/L)=μout(U/r), where U=dr(t)/dt is the dominant velocity scale. Equating the viscous stress with the Laplace pressure, ΔP, we get a differential equation that can be integrated to give:
where C1 is a dimensionless prefactor and τvisc,out=μoutA/γ.
Likewise, we can determine the dynamics when the inertial stress of the external fluid, ρoutU2, is dominant over its viscous stress. Setting U=dr(t)/dt and equating the stress with ΔP leads to:
where D1 is also a dimensionless prefactor and τinert,out=. (As noted previously31 and derived from energy balance32, this last equation has the same form as for inertial coalescence of drops in vacuum4,5,6,7,10, if ρout is replaced by ρin). Equations 2 and 3 indicate that the viscous and inertial regimes of bubble coalescence scale in the same way with only a difference in their characteristic timescales.
To test these predictions, we show r(t) versus t in Fig. 2a for air bubbles coalescing in silicone oils. All of the data have a similar slope. Thus, we can collapse them on the master curve shown in Fig. 2b by rescaling the y axis with the drop radius, A, and the x axis with a measured timescale, τout, which we fit for each outer fluid to produce the best collapse.
We plot τout versus μout in Fig. 2c. There are clearly two distinct regimes. For high viscosities, τout≈0.72τvisc,out, corresponding to C1=1.2. For low viscosities, τout ≈0.51τinert,out, corresponding to D1=1.4. Both prefactors, C1 and D1, are of order unity as expected. In a separate analysis, we determine the scaling exponent by fitting the data to a power law: r(t)∝tn and measure n=0.55±0.09 and n=0.49±0.05 at high and low viscosities, respectively. Both are consistent with n=1/2. Thus, the data in both regimes are consistent with the predicted scaling laws, equations 2 and 3.
Competition between inner and outer fluids
Returning to the two-fluid case, we now consider the competition between the stresses inside and outside the drops. As the ratio μin/μout decreases, there must be a transition from the behaviour observed in Fig. 1 (where inner flows dominate) to that seen in Fig. 2 (where the external fluid is most important).
In Fig. 3a, we show data for r(t) for salt water drops coalescing in outer fluids of different viscosities. This is similar to Fig. 1c but we have now extended the range to much smaller viscosity ratios, μin/μout. The early-time data are linear over the entire range, suggesting that the dynamics is still dominated by the inner fluid in the ILV regime. A fit to the data at later time gives: r(t)∝t0.54±0.03, which is consistent with what we see in bubble coalescence. Thus, when μout≫μin, a single coalescence event has a crossover from where the dominant flows are initially interior to where they are eventually exterior to the drops. The data can be collapsed on a master curve if we rescale by a crossover time, tcross, and crossover radius, rcross, as shown in the inset.
In Fig. 3b, the dashed line shows that there is an approximately linear dependence of the crossover radius on the viscosity ratio: rcross/A≈0.76μin/μout. To reinforce that the late-time behaviour is dominated by the outer fluid, Fig. 3c shows τout≈1.5μoutA/γ, indicating that the outer-fluid viscosity indeed controls the late-time dynamics. Using equation 2, we find C1=0.81. The presence of an inner fluid has thus changed the prefactor, C1, from what it was for bubbles. It has not, however, changed the dependence of r(t) on time or on external viscosity.
Finally, we test whether the outer fluid has any effect on the initial regime of drop coalescence. Fitting to equation 1, Fig. 3d shows the numerical prefactor, C0, versus μin/μout. This prefactor is constant to within experimental error over a wide range of μout when μin is fixed. (C0 depends weakly on μin, as was observed for drop coalescence in air14,18.) We note that the points with the largest viscosity ratio, μin/μout, correspond to drop coalescence in air, where ρout is 630–810 times smaller than in the rest of the data. These results indicate that the presence of the external fluid does not alter the early-time behaviour—coalescence always starts in the ILV regime of equation 1.
Possible crossovers between the regimes
We now consider the different possible crossovers that can exist as a pair of drops coalesce in an outer fluid. We do the most naive approximation and simply consider the crossovers between the four possible regimes outlined in Table 1. To determine the crossover, we estimate the peak stress as a function of neck radius, for each regime. When the stresses in two regimes are equal, there will be a crossover from one regime to the other.
The ILV regime has the most rapidly diverging stress at early time (small r). Therefore, in a continuum approximation, all coalescence must be asymptotically dominated by the dynamics within the drops. (Of course, if the scale where the inner viscosity dominates is below the size of an atom, then the ILV regime is cut off.) After starting in the ILV regime, the dynamics can transition into the outer-viscous, the inner-inertial, or the outer-inertial regimes. By equating stresses, we calculate the dimensionless neck radius, r/A, for each of these crossovers. We list these in Table 1. An ILV to outer-viscous crossover should occur when r/A≈μin/μout, consistent with our measurements in Fig. 3b. We expect an ILV to inner-inertial crossover when r/A≈Ohin. This is the transition seen in Fig. 1c and for drops coalescing in air14,18. Finally, we predict that if ρout is sufficiently large, an ILV to outer-inertial crossover is possible, when r/A≈μin/. (This would occur outside of the range of our bubble coalescence experiments.)
Crucially, we observe that the time dependance of the stresses in all regimes except the ILV regime are identical—they all decay as 1/t. (This comes from plugging r(t) into the stress scale of each regime.) Therefore, once a crossover occurs out of the ILV regime into a second regime, coalescence continues in that regime until the drops have completely merged. This explains why the data in Fig. 1c were completely independent of the value of μout; for these fluid parameters, the drops transition from the ILV regime into an inertial regime. They remain in that inertial regime to the end and the external viscosity does not play a role. This also implies that bubbles coalescing in an outer fluid will not have a crossover between the outer-viscous and outer-inertial regimes as a function of time. Instead, the phase boundary between the outer-viscous and outer-inertial regimes is independent of r(t) and is given by Ohout≈1, consistent with our measurements in Fig. 2c.
Two-fluid phase diagram
We assemble these results in a phase diagram for bubble and two-fluid coalescence, shown in Fig. 4. Coalescence begins (at asymptotically early times) in the ILV regime where the outer fluid is unimportant, no matter how large its density or viscosity is. In making the axes non-dimensional, an important dimensionless number emerges, given by μout/ (where ρ is the higher of the two-fluid densities). This number is determined from where the inertial stress (given by the inner or outer fluid) is equal to the viscous stress in the outer fluid. For μout/<0.3, inertia takes over at late times, whereas if μout/>0.3, then the outer-fluid viscosity dominates at late times.
This phase diagram implies that even for air bubbles coalescing in outer fluids, the viscosity of the inner fluid sets dr(t)/dt at early times, which can therefore be very fast. For air bubbles coalescing in water with A=2 mm, equation 3 predicts that dr(t)/dt exceeds the speed of sound in water for r<0.25 μm. This can produce shock waves in the water. Thus, compressibility effects will be important during the early moments of bubble coalescence.
At very small neck radii, where the drop surfaces are very close to one another, van der Waals forces can become important and, in principle, affect the scaling results derived above. At worst, this could only affect our earliest electrical data, but not our bubble coalescence data, which do not probe to such small scales. Moreover, the effect of van der Waals forces will be mitigated because we expect the neck to form when the drops or bubbles are a finite distance apart. The presence of this gap will not change the expected scalings. (See Methods section.)
Discussion
In summary, we have examined liquid drops with Ohin<1 coalescing in an outer fluid. We showed that the outer fluid has a surprisingly small effect on the coalescence dynamics. Moreover, the ILV regime is the asymptotic regime of liquid-drop coalescence, even in an outer fluid with significant density or viscosity. We expect the same to be true for Ohin>1, for the simple reason that the force balance argument that identifies the ILV regime15 is only strengthened by having a second, ambient fluid with significant density. In that argument, the acceleration of the centre-of-mass motion of a drop in the Stokes regime is compared with the forcing from surface tension that becomes arbitrarily small for small neck radius. When there is a surrounding fluid, the total mass that must be moved to bring the two drops together can only be larger than it is in vacuum. Therefore, we expect that the ILV regime should remain the asymptotic early-time regime for two-fluid coalescence, just as it is for the case with no external fluid. Further experiments are required to study the two-fluid case in the Stokes regime (which we expect to occur only at late times for Ohin>1), where there is an analytic theory4.
We note that in our scaling analysis for the two-fluid case, we have greatly simplified our picture by assuming that, at each point in time, one fluid can be completely ignored with respect to the dynamics of the other. In reality, the non-dominant fluid provides a perturbation that would affect the dimensionless prefactors of the crossovers and scaling laws, and the neck shape (as in Eggers et al.4). Our data for drops and for bubbles coalescing inside a dominantly viscous external fluid show that the prefactor can change by a factor of ≈1.5 but the scaling exponent is unaffected.
For the case of air bubbles coalescing in an outer fluid, we have experimentally determined the growth dynamics. Our measurements are consistent with our scaling arguments wherein the exponent for the growth of the neck is identical in the inertial and viscous regimes. A full theory of bubble coalescence would give a more rigorous justification and could provide insight on the flows outside of the neck region.
Finally, our work has identified a dimensionless number in two-fluid coalescence, μout/ (where ρ is the larger of the two-fluid densities), which may be used to predict whether the viscosity of the ambient fluid will ever be significant in the dynamics. This is just the Ohnesorge number for the outer fluid when ρout>ρin. However, if ρout<ρin, then it is a different dimensionless number. As we showed in the case of coalescing water drops, the outer fluid does not matter even if it is ≈50 times more viscous than the water itself.
Methods
Experiment
We measure the neck radius versus time, r(t), for drops or bubbles coalescing in an outer fluid. High-speed imaging was used for bubble coalescence and some of the two-fluid experiments; electrical measurements were performed on all of the two-fluid experiments. The methods are in good agreement where we obtained both types of data.
In both methods, two hemispherical drops or bubbles of radius A are formed on vertically aligned nozzles. The drops or bubbles are sufficiently small so that distortions due to gravity are minor. For the case of drops, we use combinations of water and glycerol to vary the interior viscosity, and we dissolve in salt (NaCl) to make them electrically conductive. The drops or bubbles are submerged in various silicone oils (Clearco Products) having a wide range of viscosity (0.49 mPa s<μout <29,000 mPa s) but small variation in density (761 kg m−3<ρout<976 kg m−3).
To initiate coalescence, one drop or bubble is grown with a syringe pump at low speed so that the interfaces are undeformed when they touch. When the outer-fluid viscosity is large, we instead bring the drops or bubbles close together and hold them there until they coalesce (usually within 10–30 min). For drops, we monitor the deformation by measuring their capacitance immediately before the moment of contact, t=0. For bubbles, deformation is visible for high μout, but it is smaller than the neck radii we measure. We record the resulting coalescence dynamics with a high-speed digital camera (Phantom series, Vision Research).
In the electrical method12,13,14,15,18,30, a high-frequency (≥800 kHz) low-amplitude (≤1 V) AC signal is applied across a known circuit element and across the drops as they coalesce. By varying the voltage and the frequency, we determined that the electric fields do not influence the coalescence dynamics of the expanding liquid neck18. Sampling the output at high speed, we follow ref. 14 to extract the complex impedance of the coalescing drops and convert it to a neck radius as a function of time: r(t).
Viscosities of the glycerol–NaCl–water mixtures were measured with glass capillary viscometers (Cannon-Fenske). Density was measured by weighing a known volume of fluid. We measured the interfacial tension, γ, for each combination of inner and outer fluids to within ±1 mN m−1 by analysing pictures of static pendant drops. For the fluid combinations used, γ varied by less than a factor of 1.15 for a fixed inner fluid. The values are given in the figure captions.
We also measured the surface tension for each oil, as well as the viscosity and density of several oils, and the measurements were found to be consistent with the manufacturer’s product specifications.
Length scale for outer fluid flows
Here we argue that when bubbles are coalescing in an ambient fluid and the interior gas has negligible viscosity and density, then the radial flow gradients of the outer fluid are over a length scale comparable to the bubble neck radius, r.
The gap between the bubbles at a radial distance L from the neck (of radius r) is given to first order by (r+L)2/A. Denoting the average radial velocity there as vL, continuity for an incompressible outer fluid gives: (2πr3/A)(dr(t)/dt)=(2π(r+L)3/A)vL. We wish to identify the length scale, L, for which vL decays to some small fraction, 1/N, of the neck speed, dr(t)/dt. Setting vL=(1/N)(dr(t)/dt), we find: L=r(N1/3−1)≈r. (In two dimensions, L=r(N1/2−1)≈r.)
Laplace pressure scaling
The value of the Laplace pressure at the neck minimum is determined by the principal radii of curvature at that point. Depending on the coalescence regime, the dominant radius of curvature can have a different dependence on r. For drops coalescing in vacuum in the ILV regime15,18 and in the Stokes regime1,4,15,18, it will be of order r3/A2; for Stokes coalescence in an external fluid at early times4 it will be of order r3/2/A1/2. Other regimes might produce other forms. However, the pressure and the flows are spread out in space, over either an axial scale r2/A, or a radial scale r. Therefore, the driving force should be determined by a spatially averaged Laplace pressure, ΔP=, where is the mean curvature, averaged over the entire neck region, and κ1, κ2 are the principal curvatures. Here we show that to leading order, is set by the spacing between the drop interfaces, r2/A, and is independent of the shape of the neck.
We consider the drops to be spheres with radius A and centres on the z axis, touching at the origin, (x,y,z)=(0,0,0). We compute the curvature in the (x,z) plane first. The interfaces of the spherical drops are approximated to first order by z=±x2/(2A). The axisymmetric neck interface follows some function f(z), which joins smoothly to the two drops at the points (/(2A)) with slopes f′≡df/dz=±A/x*, where x*≈r. The line curvature of f(z) is κ1=f′′/(1+(f′)2)3/2. Averaging over the neck, we get . To leading order, =−2A/≈−A/r2. This curvature is also present in two-dimensional (2D) coalescence.
The curvature of the neck in the (x,y) plane is simply κ2=1/r, which is an upper bound for the average value over the neck region, . This curvature need only be considered in the force balance at late times (and is absent in 2D coalescence).
Effect of small neck size
Our scaling predictions for r(t) are for an idealized version of coalescence, corresponding to a neck of radius r and height r2/A growing on two spheres of radius A. This is the same idealization used in Hopper1,2 and Eggers et al.4 However, we expect the neck to form when the drops or bubbles are a finite distance, z0, apart so the neck height is instead given by z0+r2/A. When r<<, the gap between the drops is approximately constant; later on, r≫ and so z0<<r2/A can be ignored. (This gap was found to be z0= nm for salt water drops of radius A=2 mm coalescing in air18, so in that case, ≈20 μm.)
Among the stresses listed in Table 1, only the viscous stresses change for a finite gap, z0, since the inertial stresses depend only on the fluid density and the neck speed. The peak viscous stress in the inner fluid would be μin(dr(t)/dt)/(z0+r2/A). In the outer fluid, applying the argument for a constant-height gap gives, as before, a length scale of L∝r. In our experiments, the crossovers are all observed when r>6 μm (and our bubble coalescence data are for r>100 μm), and we find good agreement with our scaling arguments using the approximation z0+r2/A≈r2/A.
Additional information
How to cite this article: Paulsen, J. D. et al. Coalescence of bubbles and drops in an outer fluid. Nat. Commun. 5:3182 doi: 10.1038/ncomms4182 (2014).
References
Hopper, R. W. Coalescence of two equal cylinders: exact results for creeping viscous plane flow driven by capillarity. J. Am. Ceram. Soc. 67, C262–C264 (1984).
Hopper, R. W. Plane Stokes flow driven by capillarity on a free surface. J. Fluid Mech. 213, 349–375 (1990).
Martínez-Herrera, J. I. & Derby, J. J. Viscous sintering of spherical particles via finite element analysis. J. Am. Ceram. Soc. 78, 645–649 (1995).
Eggers, J., Lister, J. R. & Stone, H. A. Coalescence of liquid drops. J. Fluid Mech. 401, 293–310 (1999).
Menchaca-Rocha, A., Martnez-Dávalos, A., Núñez, R., Popinet, S. & Zaleski, S. Coalescence of liquid drops by surface tension. Phys. Rev. E 63, 046309 (2001).
Duchemin, L., Eggers, J. & Josserand, C. Inviscid coalescence of drops. J. Fluid Mech. 487, 167–178 (2003).
Wu, M., Cubaud, T. & Ho, C.-M. Scaling law in liquid drop coalescence driven by surface tension. Phys. Fluids 16, L51–L54 (2004).
Aarts, D. G. A. L., Lekkerkerker, H. N. W., Guo, H., Wegdam, G. H. & Bonn, D. Hydrodynamics of droplet coalescence. Phys. Rev. Lett. 95, 164503 (2005).
Thoroddsen, S. T., Takehara, K. & Etoh, T. G. The coalescence speed of a pendent and a sessile drop. J. Fluid Mech. 527, 85–114 (2005).
Lee, T. & Fischer, P. F. Eliminating parasitic currents in the lattice Boltzmann equation method for nonideal gases. Phys. Rev. E 74, 046709 (2006).
Fezzaa, K. & Wang, Y. Ultrafast x-ray phase-contrast imaging of the initial coalescence phase of two water droplets. Phys. Rev. Lett. 100, 104501 (2008).
Case, S. C. & Nagel, S. R. Coalescence in low-viscosity liquids. Phys. Rev. Lett. 100, 084503 (2008).
Case, S. C. Coalescence of low-viscosity fluids in air. Phys. Rev. E 79, 026307 (2009).
Paulsen, J. D., Burton, J. C. & Nagel, S. R. Viscous to inertial crossover in liquid drop coalescence. Phys. Rev. Lett. 106, 114501 (2011).
Paulsen, J. D. et al. The inexorable resistance of inertia determines the initial regime of drop coalescence. Proc. Natl Acad. Sci. USA 109, 6857–6861 (2012).
Sprittles, J. E. & Shikhmurzaev, Y. D. Coalescence of liquid drops: Different models versus experiment. Phys. Fluids 24, 122105 (2012).
Baroudi, L., Kawaji, M. & Lee, T. Effects of initial conditions on the simulation of inertial coalescence of two drops. Comp. Math. Appl. 67, 282–289 (2013).
Paulsen, J. D. Approach and coalescence of liquid drops in air. Phys. Rev. E 88, 063010 (2013).
Weertman, J. Bubble coalescence in ice as a tool for the study of its deformation. J. Glaciol. 7, 155–159 (1968).
Navon, O. & Lyakhovsky, V. Vesiculation processes in silicic magmas. Geol. Soc. London, Special Publications 145, 27–50 (1998).
Espino, S. & Schenk, H. J. Mind the bubbles: achieving stable measurements of maximum hydraulic conductivity through woody plant samples. J. Exp. Bot. 62, 1119–1132 (2011).
Evans, D. F. & Wennerstrom, H. The Colloidal Domain VCH Publishers (1994).
Eow, J. S. & Ghadiri, M. Electrostatic enhancement of coalescence of water droplets in oil: a review of the technology. Chem. Eng. J. 85, 357–368 (2002).
Ahn, K., Agresti, J., Chong, H., Marquez, M. & Weitz, D. A. Electrocoalescence of drops synchronized by size-dependent flow in microfluidic channels. Appl. Phys. Lett. 88, 264105 (2006).
Yao, W., Maris, H. J., Pennington, P. & Seidel, G. M. Coalescence of viscous liquid drops. Phys. Rev. E 71, 016309 (2005).
Yokota, M. & Okumura, K. Dimensional crossover in the coalescence dynamics of viscous drops confined in between two plates. Proc. Natl Acad. Sci. USA 108, 6395–6398 (2011).
Aryafar, H. & Kavehpour, H. Hydrodynamic instabilities of viscous coalescing droplets. Phys. Rev. E 78, 037302 (2008).
Charles, G. & Mason, S. The coalescence of liquid drops with flat liquid/liquid interfaces. J. Colloid. Sci. 15, 236–267 (1960).
Gilet, T., Mulleners, K., Lecomte, J. P., Vandewalle, N. & Dorbolo, S. Critical parameters for the partial coalescence of a droplet. Phys. Rev. E 75, 036303 (2007).
Burton, J. C., Rutledge, J. E. & Taborek, P. Fluid pinch-off dynamics at nanometer length scales. Phys. Rev. Lett. 92, 244505 (2004).
Thoroddsen, S. T., Etoh, T. G., Takehara, K. & Ootsuka, N. On the coalescence speed of bubbles. Phys. Fluids 17, 071703 (2005).
Czerski, H. A candidate mechanism for exciting sound during bubble coalescence. J. Acoust. Soc. Am. 129, EL83–EL88 (2011).
Acknowledgements
We thank Osman Basaran, Efi Efrati and Wendy Zhang for many enlightening discussions. We thank Irmgard Bischofberger and Andrzej Latka for measurements of fluid parameters of the silicone oils used. J.D.P. gratefully acknowledges a Grainger Foundation Fellowship. This work was supported by NSF Grant DMR-1105145, NSF-MRSEC DMR-0820054 and NSF-PREM DMR-0934192.
Author information
Authors and Affiliations
Contributions
J.D.P., R.C., A.K., J.C.B. and S.R.N. designed the experiments and interpreted the results. J.D.P., R.C. and A.K. performed the experiments. J.D.P. and S.R.N. wrote the manuscript with revisions from all of the authors.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
About this article
Cite this article
Paulsen, J., Carmigniani, R., Kannan, A. et al. Coalescence of bubbles and drops in an outer fluid. Nat Commun 5, 3182 (2014). https://doi.org/10.1038/ncomms4182
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms4182
This article is cited by
-
Modelling droplet size distribution in inline electrostatic coalescers for improved crude oil processing
Scientific Reports (2023)
-
Coalescence and mixing dynamics of droplets in acoustic levitation by selective colour imaging and measurement
Scientific Reports (2023)
-
The rich inner life of the cell nucleus: dynamic organization, active flows, and emergent rheology
Biophysical Reviews (2020)
-
Modeling Geometric State for Fluids in Porous Media: Evolution of the Euler Characteristic
Transport in Porous Media (2020)
-
Numerical Simulation of Coalescence of Two-Phase Media in Packed-Bed Static Mixers
Chemical and Petroleum Engineering (2019)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.