Abstract
Multiplexed or simultaneous detection of multiple analytes is a valuable tool in many analytical applications. However, complications caused by the presence of interfering compounds in a sample form a major drawback in existing molecular sensor technologies, particularly in multi-analyte systems. Although separating analytes through extraction or chromatography can partially address the problem of interferents, there remains a need for developing direct observational tools capable of multiplexing that can be applied in situ. Surface-enhanced Raman Spectroscopy (SERS) is an optical molecular finger-printing technique that has the ability to resolve analytes from within mixtures. SERS has attracted much attention for its potential in multiplexed sensing but it has been limited in its quantitative abilities. Here, we report a facile supramolecular SERS-based method for quantitative multiplex analysis of small organic molecules in aqueous environments such as human urine.
Similar content being viewed by others
Introduction
SERS is a highly sensitive surface technique that enhances inherently weak Raman signals from molecules that are localised in regions of intense optical fields trapped between adjacent plasmonic surfaces, called ‘hot-spots’1. Noble metal nanoparticles are favoured for small molecule analysis as they allow in situ detection within liquid media, compatible with microfluidic devices2. Furthermore, their low cost, commercial availability and ease of synthesis without the need for sophisticated instruments renders them practical for widespread use.
In the last few years, the realisation that SERS is an ideal technique for analysis of multiple analytes simultaneously, i.e. multiplexing, has drawn considerable interest. Multiplexing is desirable to eliminate the steps that are often required to isolate the analyte of interest from a complex mixture of compounds3. Despite its advantages, the quantification of SERS, especially for multiplexing, has been challenging as a result of irreproducible SERS intensities4,5. While semi-quantitative methods have been widely reported in the literature, there are no examples of supramolecular SERS-based quantitative multiplexed methods5,6,7,8,9.
Several approaches have focused on obtaining highly-controlled SERS signals, for instance through using DNA-oligomers10,11, alignment of nanoparticle arrays at multi-phase interfaces12 and others4. One such strategy, applicable in aqueous media, utilises rigid spacer macrocyclic host molecules, cucurbit[n]urils13 (CB[n]), to create precisely spaced sub-nanometre gaps in between adjacent nanoparticles14,15. The resultant reproducible hot-spot regions generate quantitative SERS signals16. In addition, analytes of interest can be localised near the surface of the gold nanoparticles through their affinity to the CB[n] cavity17. Therefore, CB[n] provides an ideal supramolecular approach for the generation of quantitative SERS signals.
CB[7] can accommodate an aromatic compound inside its cavity to form 1:1 guest·CB[7] complexes in aqueous solutions (Figure 1a). Host-guest complex formation with CB[7] is mainly driven by the release of high-energy water from inside the hydrophobic cavity of CB[7]18. Further electrostatic interactions between cationic guest molecules and the carbonyl portals of CB[7] lead to additional stabilisation of such complexes. CB[7] is selective towards a class of molecules instead of being specific for single target analytes only. Such a generic receptor is ideal for the development of a multiplexed chemosensor, where several structurally-similar compounds can be resolved spectroscopically, as in SERS.
A number of neurotransmitters act as disease biomarkers and are common analytes of interest in medical diagnostics, including microdialysates and urine samples19,20. In order to demonstrate the potential of this CB[7]-mediated SERS system in multiplexed chemical analysis, three such monoamine neurotransmitters were chosen for this study: dopamine (DA), epinephrine (EPI) and serotonin (5HT). Electrochemical methods and mass spectroscopy are the most conventional choices for the detection of these neurotransmitters21, while optical methods include fluorescent labelling using specifically designed molecular tags22. However, such methods are often impractical for real sample analyses as they are limited by their need for additional separation strategies and their lack of ability to identify (or quantify) multiple analytes simultaneously for the direct detection of these neurotransmitters in complex environments20. Enzyme-linked immunosorbent assay systems have also recently been reported for the detection of dopamine23 but such current state-of-the-art techniques are still limited by drawbacks such as low applicability in multi-analyte systems, low availability of antibody reagents, long time-scales for assay development (multiple days to weeks), sensitivity to storage conditions and reduced specificity in the presence of structural analogues of the target analytes6. Herein, we show an exemplary study with the aforementioned three biogenic amines to highlight the applicability of the facile CB[n]-based SERS sensing for multiplexing.
Results
Binding of CB[7] with analytes
DA and EPI are structurally similar molecules with catecholamine frameworks, whereas 5HT contains an indole moiety (Figure 1a). The three neurotransmitters show relatively similar binding affinities for CB[7] (104 to 105 M−1), as determined by NMR studies (Supplementary Figures S1–S4) and isothermal titration calorimetry (Supplementary Figure S5). All three monoamines bind to CB[7] with a 1:1 stoichiometry. In water (at pH 7), the amine groups on the neurotransmitters are protonated and contribute to the binding with CB[7] through stabilizing electrostatic interactions with the carbonyl portals (Supplementary Note S.1.2).
When EPI, DA and 5HT are present together in an aqueous solution containing excess CB[7], the binding behaviour of CB[7] towards the three individual analytes is not affected, as evidenced by the Diffusion Ordered Spectroscopy 1H NMR of their complexed mixture (Figure 2). The presence of excess CB[7] is key in this case. In the absence of sufficient concentration of CB[7] for all three neurotransmitters, the guests compete for the host with similar affinities, which results in unbound neurotransmitters in the solution (Supplementary Figure S6).
Aggregation of nanoparticles
DA, EPI and 5HT are unable to aggregate gold nanoparticles (AuNPs) at low concentrations (≤5 × 10−5 M) and therefore, cannot be analysed by SERS directly in the absence of an aggregating agent. However, with subsequent addition of CB[7], AuNP cluster formation is induced with uniform gap distances between adjacent nanoparticles14 (Figure 1b). This allows for observation of SERS signals from the analytes well below 5 × 10−5 M (limit of detection < 10−9 M), which get trapped inside the CB[7] cavity (Figure 1c, Supplementary Figure S7). The kinetics of CB[n]-induced AuNP aggregation has been shown to be fully reproducible using fixed concentrations of CB[n] and aqueous nanoparticles14,16. The clusters are formed within a few seconds after addition of CB[7], immediately enabling SERS data acquisition. In this particular study, SERS spectra were acquired after approximately 30 seconds of addition of CB[7] and acquisition was completed within the first minute of aggregation. However, it is noteworthy that SERS intensities remain stable over time and only show a slight decrease over 30 minutes (Supplementary Figures S8–S9). Therefore, measurements do not have to be taken at precise or exact time points after addition of CB[7] and spectra can be recorded within several minutes after the aggregation process has been initiated.
SERS data analyses
While each analyte can be individually detected and quantified by SERS when analysed separately (Supplementary Figures S10–S11), the presence of multiple analytes in a mixture obscures the SERS spectra and visual inspection of such data becomes difficult (Supplementary Figures S12–S13). Numerical chemometric methods simplify the spectral deconvolution process by using relevant calibration or ‘training’ data24. The principle of the analysis is analogous to the widely used analytical approach, where a calibration curve of known magnitude is prepared as a reference for the determination of unknown values in subsequent test measurements (Figure 3). It is particularly suited to extract quantitative information from spectra with multiple peaks where visual inspection is difficult (Figure 4a,b). At first a set of SERS data comprising triplicates of thirty different aqueous mixtures was collected for training the predictive numerical models, where the concentrations of DA, EPI and 5HT were varied, while the concentration of CB[7] was held constant. A broad range of concentrations were chosen, between 0.5 × 10−6 M and 10 × 10−6 M, to include expected clinical uretic concentrations of the neurotransmitters. This dataset formed the equivalent ‘calibration curve’ in this study. A second set of data, or the ‘test set’, was then collected comprising aqueous mixtures of neurotransmitters at randomly selected concentrations.
Firstly, the presence or absence of an analyte from the test mixtures was determined by Artificial Neural Networks (ANNs)25,26. ANNs are inspired by and imitate natural neural networks. They are widely used in pattern recognition and classification of specimens into known classes26. ANNs consist of interconnected neurons, or ‘nodes’, arranged into input, intermediate (hidden) and output layers. There may be one or more intermediate layers, the number of which is determined based on a residual analysis during the training process. The connections between nodes are assigned random weights at first. During the training or ‘learning’, these weights are iteratively adjusted when the algorithm is presented with an input pattern and a corresponding output pattern by comparing their differences. This process is repeated until the computed output matches the desired output. The resulting optimised or ‘trained’ network is then used to determine the unknown output parameter using a set of measured input data.
For this study, a simple ‘three-layer feed-forward network’, consisting of one hidden layer was used. Using the calibration data collected earlier, the algorithm was trained such that values of ‘0’ indicate the absence and values of ‘1’ the presence of a component. Such qualitative tests are common in screening illicit drugs, particularly in urine, using immunoassays. The results showed that it was possible to correctly detect the presence or absence of an analyte in a mixture, the neurotransmitters in this case, by application of ANNs on the spectral data of the mixtures collected with CB[7] (Supplementary Figure S14). Out of a total of 24 predictions (for 3 analytes in 8 samples), 22 predictions were correct, while 2 results were false positives (Supplementary Note S.4.1). This represents a 92% prediction accuracy, which is comparable to immunoassays. It must be noted that all positive results in drug screening remain presumptive until confirmed by a secondary method such as gas chromatography27,28. Therefore, the obtained results highlight the potential of this SERS-based method in preliminary qualitative screening of analytes.
Next, the potential of this method for measuring absolute concentrations of individual analytes was examined. After an initial comparison with other multivariate methods, namely Principle Component Regression (PCR), the well-established Partial Least Squares Regression (PLSR)29 method was chosen for further studies on account of better performance30. The same training and test datasets were used for the analyses as before. In brief, PLSR is a well-established multivariate regression method that can be used to extract sample concentrations from optical spectra31,32. It builds a predictive model that is based on the underlying factors that are responsible for the majority of the variation in the experimentally observed spectra. At the same time, it ensures that each of those factors is directly related to the analyte concentrations. Factors that only explain small variations in the spectrum such as noise are excluded from the model29. This reduction to relevant factors makes the predictive abilities of a PLSR model more robust compared to a simple linear regression model.
The PLSR model was trained using the calibration data collected earlier and validated with the ‘test set’. The average error in the measured absolute concentrations of the analytes in the test samples was within ±6 × 10−7 M of the expected concentrations in the test range between 0.5 × 10−6 M and 10 × 10−6 M. (Figure 4c, see Supplementary Note S.2.4 and Supplementary Figures S15–S18 for analytical details).
The measurements were repeated in commercial reconstituted lyophilised human urine to test the applicability of this sensor in a more complex biological media, especially at clinically relevant levels (between 0.5 × 10−7 M and 1 × 10−6 M). Signals from CB[7] are visible in the SERS spectra even when the AuNPs were redispersed in urine (Figure 4b) and the presence of all three uretic neurotransmitters could be readily detected using the trained ANN. The predicted amount of catecholamines present in the commercial sample was within the expected range specified by the supplier. Furthermore, when these urine samples were spiked with the three neurotransmitters, the increase in their respective concentrations could readily be quantified by PLSR (Figure 4d, Supplementary Figure S21). These results highlight the robustness and applicability of this system in complex media, even at normal biological concentrations.
Discussion
It is important to note that the calibration of the system effectively eliminates the influence of the differences in binding affinities of the analytes towards CB[7] on the final results. The system is entirely based on dynamic supramolecular interactions, i.e. assembly process of nanoparticles and guest inclusion inside CB[7], which accounts for some degree of inter and intra-assay variability. Despite the variability, however, the results are reproducible and only limited by the lowest training value of the calibration range. It is also worth mentioning that the errors could likely be further reduced by using more accurate sampling systems (i.e. autosamplers) as well as using a higher number of repeat samples for calibrating the system. Here, the samples were prepared by a single researcher through serial dilutions, using eppendorf micropipettes with different volume ranges and an average of three repeat samples were measured. Automation will tremendously reduce the time required for preparing samples accurately for calibration, but would not increase the time required for analysis of each sample.
To conclude, the absolute determination of analyte levels at low concentrations is usually challenging using colloidal SERS substrates, especially in multiplexed analysis. Thus, this system represents the first SERS-based supramolecular system with multiplexing abilities in aqueous media. The CB[n] gold nanoparticle system is solely based upon self-assembly and does not require expensive and time-consuming preparation or storage of specialised SERS substrates, pre-functionalisation, or separation steps. Given the versatility of CB[7] binding to a range of guest molecules, the multiplexing abilities of this technique can be expanded well beyond biological applications. Its potential portability, fast processing times (in under 10 minutes), simplicity and low cost make it a particularly attractive strategy. The method developed in this work can be automated with ease for high throughput analyses and could have tremendous impact on a broad range of applications.
Methods
All starting materials were purchased from Alfa Aesar and Sigma Aldrich and used as received unless stated otherwise. CB[7] and CB[8] were synthesized according to literature methods33. Millipore 18 MΩ.cm H2O was used in all experiments unless stated otherwise. Standard stock solutions of all neurotransmitters were freshly prepared prior to analysis. 60 nm citrate-stabilised gold nanoparticles were purchased from British Biocell International. Lyophilised urine samples for catecholamines (Calibrator Lot No. 150 and Control Level II Lot No. 230) were obtained from RECIPE ClinChek-Control. The lyophilised urine samples were reconstituted in dilute hydrochloric acid as specified by the supplier.
Nuclear magnetic resonance spectroscopy
1H NMR and DOSY spectra were recorded on a Bruker Avance 500 BB-ATM (500 MHz) spectrometer. DOSY experiments were carried out using a modified version of the Bruker sequence ledbpgp2s. Spectra were recorded in heavy water (D2O) at 298 K. The concentration of CB[7] was fixed at 1 × 10−3 M for all the samples. The experiments were processed with standard Bruker 1D and 2D DOSY software. The diffusion coefficients were determined by fitting the intensity decays to equation 1.
where, I and I0 represent the signal intensities in the presence and absence of gradient pulses respectively, D is the diffusion coefficient, γ is the 1H gyromagnetic ratio, δ is duration of the gradient pulse, Δ is the total diffusion time and g is the applied gradient strength.
For the 1D titration studies, a series of of solutions were prepared by adding calculated volumes of 4 mM of stock solutions of the guest molecules in D2O into 2 mM solution of CB[7], also in D2O. The spectra was processed using Mestronova NMR processing software.
Isothermal titration calorimetry
Isothermal titration experiments were carried out on a NanoITC (TA Instruments) at 25°C in water. The binding equilibria was studied using a cellular CB[7] concentration of 0.1 mM (950 μL) to which a 10-times higher concentrated guest solution was titrated. Typically 25 consecutive injections of 10 μL each were used. All solutions were degassed for at least 15 minutes prior to titration. Heats of dilution were determined by titration of the guest solution into water. The first data point was removed from the data set prior to curve fitting. The data was analyzed with the inbuilt software (NanoAnalyse) with the ‘independent sites’ model.
Surface-enhanced Raman spectroscopy
Raman and SERS spectra were acquired using a 785 nm laser (17.5 mW) and recorded with an Ocean Optics QE65000 Spectrometer. Acquisition time for each spectra was 10 seconds. 200 μL of the 60 nm gold nanoparticle solution was added to a 10 μL pre-mixed CB[7] and neurotransmitter solution (prepared at higher concentrations to make up the final concentrations as required). For analysis of urine samples, CB[7] and neurotransmitters were added to make up the required final concentration. 200 μL gold nanoparticle colloids were centrifuged at 12000 rpm for 60 seconds and 190 μL of supernatant was discarded before addition to 200 μL of urine sample. The extra centrifugation step was carried out in order to maintain the same number of nanoparticles as used in the water samples.
Multivariate analysis
Multivariate data analysis was performed in Matlab (version 8.1). Artificial Neural Networks analysis was carried out using OXLearn, a matlab-based package34. The implemented algorithms contained in the Statistics Toolbox (version 8.2) were used to perform Partial Least Squares Regression. Matlab scripts written by ourselves were used to pre- and postprocess the data (additional information available in Supplementary Note S3).
References
Le Ru, E. & Etchegoin, P. Principles of Surface-Enhanced Raman Spectroscopy: and related plasmonic effects. [Le Ru, E. & Etchegoin, P. (eds.)] (Elsevier Science, Oxford, 2008).
Saha, K., Agasti, S. S., Kim, C., Li, X. & Rotello, V. M. Gold nanoparticles in chemical and biological sensing. Chem. Rev. 112, 2739–2779 (2012).
Rinken, T. State of the Art in Biosensors - General Aspects [Rinken, T. (ed.)] (InTech, Rijeka, 2013).
Bell, S. E. J. & Sirimuthu, N. M. S. Quantitative surface-enhanced Raman spectroscopy. Chem. Soc. Rev. 37, 1012–24 (2008).
Dougan, J. A & Faulds, K. Surface enhanced Raman scattering for multiplexed detection. The Analyst 137, 545–554 (2012).
Rodriguez-Lorenzo, L., Fabris, L. & Alvarez-Puebla, R. A. Multiplex optical sensing with surface-enhanced Raman scattering: a critical review. Anal. Chim. Acta. 745, 10–23 (2012).
Wang, Y., Yan, B. & Chen, L. SERS tags: novel optical nanoprobes for bioanalysis. Chem. Rev. 113, 1391–1428 (2013).
Cialla, D. et al. Surface-enhanced Raman spectroscopy (SERS): progress and trends. Anal. Bioanal. Chem. 403, 27–54 (2012).
Zachhuber, B., Carrillo-Carrión, C., Simonet Suau, B. M. & Lendl, B. Quantification of DNT isomers by capillary liquid chromatography using at-line SERS detection or multivariate analysis of SERS spectra of DNT isomer mixtures. J. Raman Spectrosc. 43, 998–1002 (2012).
Graham, D., Thompson, D. G., Smith, W. E. & Faulds, K. Control of enhanced Raman scattering using a DNA-based assembly process of dye-coded nanoparticles. Nature Nanotech. 3, 548–551 (2008).
Lim, D. K. et al. Highly uniform and reproducible surface-enhanced Raman scattering from DNA-tailorable nanoparticles with 1-nm interior gap. Nature Nanotech. 6, 452–460 (2011).
Cecchini, M. P., Turek, V. A., Paget, J., Kornyshev, A. A. & Edel, J. B. Self-assembled nanoparticle arrays for multiphase trace analyte detection. Nature Mater. 12, 165–71 (2012).
Masson, E., Ling, X., Joseph, R., Kyeremeh-Mensah, L. & Lu, X. Cucurbituril chemistry: a tale of supramolecular success. RSC Adv. 2, 1213–1247 (2012).
Taylor, R. W. et al. Precise subnanometer plasmonic junctions for SERS within gold nanoparticle assemblies using cucurbit[n]uril “glue”. ACS Nano 5, 3878–3887 (2011).
Tao, C. et al. Cucurbit[n]urils as a SERS hot-spot nanocontainer through bridging gold nanoparticles. Chem. Commun. 47, 9867–9869 (2011).
Kasera, S., Biedermann, F., Baumberg, J. J., Scherman, O. A. & Mahajan, S. Quantitative SERS using the sequestration of small molecules inside precise plasmonic nanoconstructs. Nano Lett. 12, 5924–5928 (2012).
Roldan, M. L., Sanchez-Cortes, S., Garcia-Ramos, J. V. & Domingo, C. Cucurbit[8]uril-stabilized charge transfer complexes with diquat driven by pH: a SERS study. Phys. Chem. Chem. Phys. 14, 4935–4941 (2012).
Biedermann, F., Uzunova, V. D., Scherman, O. A., Nau, W. M. & De Simone, A. Release of high-energy water as an essential driving force for the high-affinity binding of cucurbit[n]urils. J. Am. Chem. Soc. 134, 15318–15323 (2012).
Marc, D. T., Ailts, J. W., Campeau, D. C. A., Bull, M. J. & Olson, K. L. Neurotransmitters excreted in the urine as biomarkers of nervous system activity: validity and clinical applicability. Neurosci. Biobehav. Rev. 5, 635–44 (2011).
Perry, M., Li, Q. & Kennedy, R. T. Review of recent advances in analytical techniques for the determination of neurotransmitters. Anal. Chim. Acta. 653, 1–22 (2009).
Jackowska, K. & Krysinski, P. New trends in the electrochemical sensing of dopamine. Anal. Bioanal. Chem. 405, 3753–3771 (2013).
Maue, M. & Schrader, T. A color sensor for catecholamines. Angew. Chem. Int. Ed. 117, 2305–2310 (2005).
Nichkova, M., Wynveen, P. M., Marc, D. T., Huisman, H. & Kellermann, G. H. Validation of an ELISA for urinary dopamine: applications in monitoring treatment of dopamine-related disorders. J. Neurochem. 125, 724–35 (2013).
Miller, J. N. & Miller, J. C. Statistics and Chemometrics for Analytical Chemistry [Miller, J. N. & Miller, J. C. (eds.)] (Prentice Hall, Gosport, 2010).
Schulze, H. G. et al. Artificial neural network and classical least-squares methods for neurotransmitter mixture analysis. J. Neurosci. Meth. 56, 155–67 (1995).
Cherkassky, V., Friedman, J. H. & Wechsler, H. From Statistics to Neural Networks: Theory and Pattern Recognition [Cherkassky, V., Friedman, J. H. & Wechsler, H. (eds.)] (Springer-Verlag, Berlin, 1994).
Saitman, A., Park, H. & Fitzgerald, R. L. False-Positive Interferences of Common Urine Drug Screen Immunoassays: A Review. J. Anal. Toxicol. 38, 387–396 (2014).
Tenore, P. L. Advanced Urine Toxicology Testing. J. Addict. Dis. 29, 436–448 (2010).
Wold, S., Sjöström, M. & Eriksson, L. PLS-regression: a basic tool of chemometrics. Chemom. Intell. Lab. Syst. 58, 109–130 (2001).
Thomas, E. V. & Haaland, D. M. Comparison of Multivariate Calibration Methods for Quantitative Spectral Analysis. Anal. Chem. 62, 1091–1099 (1990).
Nakagawa, H. et al. Evaluation of Infrared-Reflection Absorption Spectroscopy Measurement and Locally Weighted Partial Least-Squares for Rapid Analysis of Residual Drug Substances in Cleaning Processes. Anal. Chem. 84, 3820–3826 (2012).
Xu, D. et al. Simultaneous determination of traces amounts of cadmium, zinc and cobalt based on UV–Vis spectrometry combined with wavelength selection and partial least squares regression. Spectrochim. Acta A. 123, 430–435 (2014).
Kim, J. et al. New Cucurbituril Homologues: Synthesis, Isolation, Characterization and X-ray Crystal Structures of Cucurbit[n]uril (n = 5, 7 and 8). J. Am. Chem. Soc. 122, 540–541 (2000).
Ruh, N. & Westermann, G. OXlearn: A new MATLAB-based simulation tool for connectionist models. Behav. Res. Methods 41, 1138–1143 (2009).
Acknowledgements
The authors thank Ms. Anna Andreou for the 1H-NMR measurements and acknowledge funding from Walters-Kundert Trust, EPSRC (EP/K028510/1, EP/G060649/1, EP/H007024/1, ERC LINASS 320503), an ERC starting investigator grant (ASPiRe 240629), EU CUBiHOLE grant. S.K. thanks Krebs Memorial Scholarship (The Biochemical Society) and Cambridge Commonwealth Trust for funding.
Author information
Authors and Affiliations
Contributions
S.K. designed and performed experiments, prepared figures, analysed data and wrote the paper; L.O.H. analysed data; J.d.B. designed and performed DOSY 1H-NMR experiments; J.J.B. and O.A.S. supervised through the experimental design, data analyses and writing of the paper.
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Electronic supplementary material
Supplementary Information
Supplementary Information: Quantitative multiplexing with nano-self-assemblies in SERS
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Kasera, S., Herrmann, L., Barrio, J. et al. Quantitative multiplexing with nano-self-assemblies in SERS. Sci Rep 4, 6785 (2014). https://doi.org/10.1038/srep06785
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep06785
This article is cited by
-
Cucurbit[8]uril-mediated SERS plasmonic nanostructures with sub-nanometer gap for the identification and determination of estrogens
Microchimica Acta (2023)
-
Microfluidic SERS devices: brightening the future of bioanalysis
Discover Materials (2022)
-
A Statistical Approach of Background Removal and Spectrum Identification for SERS Data
Scientific Reports (2020)
-
Optical absorption in array of Ge/Al-shell nanoparticles in an Alumina matrix
Scientific Reports (2020)
-
Extreme nanophotonics from ultrathin metallic gaps
Nature Materials (2019)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.