Introduction

Austenitic stainless steels including 304/304L and 316L are critical structural alloys used in a diverse number of engineering applications due to a combination of good mechanical properties, weldability, and overall corrosion resistance. However, intergranular corrosion (IGC) in austenitic stainless steels and other alloys can have a devastating effect on many of these industries, including nuclear, naval ship structures, high temperature processing equipment, and off-shore wind turbines. IGC in austenitic stainless steels is linked to the sensitization of the grain boundary (GB) network. GB sensitization can occur during welding and heat treatment in the 500–800 °C temperature regime and results in the precipitation and growth of deleterious GB Cr-rich carbides and subsequent Cr-depleted zones.1,2,3 Significant effort has been made to mitigate the deleterious effects of sensitization by introducing a high density of GBs resistant both Cr-rich carbide formation and IGC through grain boundary engineering (GBE).4,5,6,7,8,9,10 GBE is the process of introducing a specific type and density of GBs through thermomechanical processing (TMP) to improve a GB-dependent property. Previous studies have shown GBE to be a successful method in mitigating intergranular stress corrosion cracking,11,12 IGC,5,13,14 hydrogen embrittlement,15 and grain growth.16

GBE is typically associated with the increase in specific coincidence site lattice (CSL) GBs, which have been considered special boundaries.4 Early research within the field of GBE described some or all low Σ CSL GBs as special. It is apparent, however, that low Σ CSL boundaries cannot exclusively describe low energy, low excess volume, or special GB properties.17 The full GB character distribution, including GB plane normal and misorientation, is required to describe the macroscopic GB structure. Nevertheless, the use of the term “special” or low Σ CSL boundaries is convenient, and thus GBE is most often related to the large increases seen in the fraction of twin (Σ3), both coherent and non-coherent, and twin-related GBs, Σ3n (n > 1) in low to medium stacking fault materials such as Ni-based alloys, austenitic stainless steels, and copper after TMP.

A more recent approach to the characterization of GB networks in heavily twinned microstructures is the use of the following descriptors: twin-related grain clusters or twin-related domains (TRD).1823 Gertsman et al.24 defined a twin-related grain cluster as a region of a microstructure in which all of the GBs within a given cluster of grains are described by a Σ3n (n ≥ 1) misorientation. Fang et al.25 and Xia et al.26 implement the grain cluster analysis in studies of GBE stainless steel and Ni-based Alloy 690, respectively. Hu et al.5 examined grain clusters of related Σ3n GBs in engineered 316 stainless steel and found that only Σ3 coherent twins (Σ3c) inside the grain cluster are resistant to IGC. In a similar fashion to the twin grain cluster studies above, Reed et al.27 and Cayron28 described a TRD as a large cluster of twin-related grains. Reed et al.29 show that TRDs between an as-received Ni-based Alloy 600 have simple twinning and are isolated from the random high-angle GB network while, in contrast, the TRDs of GBE condition possess a high density of twin-related GBs and a break-up of the random GB network. While these studies showed that TRDs are relevant GB network descriptor for heavily twinned microstructures, there has been limited correlation between TRD statistics and IGC response of different TMP microstructures.

In this study, we provide insight into how TRD statistic between a GBE and solution anneal (SA) condition can be used to effectively understand and correlate IGC phenomena. Furthermore, the manuscript highlights how IGC propagation and arrest occur in the context of TRDs in the heavily twinned GBE condition. We observe that twin-related GBs inside TRDs effectively stop or arrest IGC propagation due to triple junctions in the domain interior that contain either (1) two Σ3 coherent boundaries, or (2) a Σ3 coherent boundary and a low-angle GB. The analysis highlights the observation that despite the TRDs’ ability to stop corrosion propagation, particular situations exist, due to higher-order non-corrosion-resistant twin-related GBs, which allow corrosion damage to run through the length or middle of the TRD. Therefore, not only is it important to distinguish between coherent and non-coherent Σ3, but also, it is critical to delineate higher-order twin boundaries from one another, all of which occur inside the TRD. To complement the TRD network IGC analysis between a GBE and non-GBE microstructure, double loop-electrochemical potentiokinetic reactivation (DL-EPR) and intergranular mass loss testing was also completed to determine the degree of sensitization (DOS) after sensitization heat treatments. The DL-EPR method has been widely used to quantitatively examine DOS and IGC susceptibility in stainless steels.30,31,32,33 Overall, the study shows that using TRDs as an effective and useful microstructural GB network descriptor provide enhanced insight into individual GB and GB network IGC phenomena in GBE stainless steel.

Results

GB and triple junction type distribution

The Σ3 GB length fraction including coherent and non-coherent twin segments increased from 47 to 68%, while the Σ9+Σ27 combined GB length fraction increased from 0.4 to 8.8% from the SA to GBE condition. The increases in the Σ3 and Σ3n (n > 1) length fraction observed after TMP are consistent with previously reported GBE processing in 304 or 316 type stainless steels.5,34,35 Table 1 provides the distribution of triple junction types, a descriptor of GB network connectivity, for both conditions. There is a significant increase in triple junctions containing two Σ3 GBs from the SA to GBE condition. The distribution of GBs in a triple junction, while offering an overview of how different GBs are connected in the overall GB network, does not provide a method to understand local GB connectivity related to IGC.

Table 1 Distribution of triple junction types for the SA and GBE condition

Twin-related domains

TRDs for the GBE and SA condition are shown in Fig. 1a and c, where a number identifies a unique grain orientation. Figure 1b and d shows the corresponding twinning tree for the GBE and SA TRDs where each unique grain orientation is classified as a node and are linked exclusively by Σ3 relationship. In total, the TRD examined in this study for the GBE condition had 45 distinct orientations, whereas the SA condition had three distinct orientations. All GBs inside the TRD interior are twin-related GBs (Σ3n, n ≥ 1) and have less than 2° deviation from their ideal CSL misorientation. A large fraction of these GBs are Σ3, Σ9, or Σ27 and are represented by red (Σ3) and blue (Σ9, Σ27) colored lines in Fig. 1. Other high and low-angle GBs exist in TRDs and are represented by black (high-angle GB) and purple (low-angle GB) colored lines which correspond to Σ34 or higher-order twin relationships. Important for IGC analysis and GB connectivity, low-angle GBs can form through multiple twinning events. Two low-angle GBs that occur in GBE TRDs are: 12.2° <3 1 1> and 7.36° <1 1 0> which are both Σ243 (Σ35) relationships.36 The ability to analyze the GB network with the TRD twinning tree provides a more expansive and detailed overview of the GB character. Specifically, the twinning tree provides the ability to track higher-order Σ3 relationships in the TRD.

Fig. 1
figure 1

a Representative TRD for the GBE condition where each orientation is given a number, while the grain color is based on the inverse pole figure scheme. b Corresponding TRD twinning tree from a where each orientation is linked by a Σ3 relationship. c Representative TRD for the SA condition where each orientation is given a number, while the grain color is based on the inverse pole figure scheme. d Corresponding TRD twinning tree from c where each orientation is linked by a Σ3 relationship. In the TRD maps a and c, Σ3 GBs are colored red, Σ9 and Σ27 GBs are colored blue, while high-angle and low-angle GBs are colored black and purple, respectively. Scale bar in a and c are 200 and 75 µm, respectively

Connecting IGC to TRD statistics

Figure 2a shows the representative DL-EPR curves for the SA and GBE conditions after the 1 h and 50 h 675 °C sensitization heat treatment. A higher DOS (2.7%) is observed for the SA condition compared to the DOS (0.25%) obtained in the GBE condition for the 1 h sensitization condition. The 1 h sensitization condition of the GBE condition indicates a lack of consistent reactivation peak (Ir), which correlates with samples having a minimal density of Cr-rich carbides and subsequently chromium-depleted zones along the GB network. The SA condition with a 2.7% DOS indicates a low to moderate DOS value which is also consistent with the relatively short sensitization heat treatment for low carbon Fe, Ni, Cr, and Mo containing stainless steels such as 316L. The 50 h sensitization heat treatment, shown in Fig. 2b, indicates higher DOS for both the SA and GBE conditions. The DOS for the SA condition was found to be nearly double that of the GBE condition. Specifically, the average DOS for the SA and GBE conditions was 95 and 46.5%, respectively. The high DOS in the SA condition is consistent with significant GB attack due to the formation of Cr-rich carbides and subsequent GB Cr-depleted zones during sensitization.

Fig. 2
figure 2

DL-EPR curves for the SA and GBE conditions for both a 1 h sensitization heat treatment and b 50 h sensitization heat treatment. The DOS can be estimated from the peak current densities of the forward and reverse scans, using Eq. 1

Figure 3 shows the IGC response and corrosion rate for the SA and GBE conditions for both the 1 and 50 h sensitization conditions during 120 h exposure to the FS-SA ASTM 262 Practice B test. The GBE condition has significantly reduced corrosion rates in both the low sensitization and high sensitization regime compared to the SA condition. As expected, the corrosion rate and IGC attack is more significant after 50 h at 675 °C in both the GBE and SA condition. The low and high sensitization treatment in the SA sample has a high degree of connected IGC regions, while the GBE sample has more scattered, disjointed IGC regions. Unlike the GBE condition in the 50 h sensitization treatment, the SA condition visually indicates the presence of significant grain drop out, a key indication of a lack IGC resistance.

Fig. 3
figure 3

IGC observed after 120 h in the ASTM A262 test for the a SA condition with 1 h sensitization, b GBE condition with 1 h sensitization, c SA condition with 50 h sensitization, d GBE condition with 50 h sensitization. ef Schematic illustrating observed correlation between TRD size and corroded GBs in the SA and GBE condition. Scale bar is 200 µm

In order to validate using TRDs as an effective microstructural descriptor to evaluate IGC in heavily twinned microstructures, Table 2, reproduced from a previous publication from the authors,23 outlines TRD statistics from the SA and GBE conditions. Specifically, the number of unique orientations, TRD average size, and the ratio of TRD to grain size provide a statistical examination of the variation in TRDs between the GBE and SA condition. The GBE condition indicates a significant increase in the TRD to grain size ratio. This TRD to grain size ratio indicates that the GBE condition, in comparison to the SA, contains spatially large TRDs but also contains twin limited small grains within the TRD. Table 2 further indicates that the overall TRD size, measured as the effective TRD circular diameter from 50 individual TRDs, shows a substantial increase from the SA to GBE condition. Overall, the IGC bulk testing and correlated TRD statistics indicate that microstructures that contain larger TRDs with a high density of Σ3 GBs in the TRD interior have improved IGC resistance. Figure 3e and f shows a proposed schematic of how the size of the overall TRD can be a descriptor of the observed IGC behavior. The small TRDs observed in the SA condition have a high degree of connected and corroded GBs, while the large TRDs observed in the GBE condition have a discontinuous network of corroded GBs.

Table 2 TRD microstructural statistics relevant to IGC for the SA and GBE condition

Propagation of IGC through TRDs

Figure 4 indicates the propagation of IGC at the exterior of two TRDs in the GBE condition. Figure 4a and b shows the SEM and inverse pole figure colored map images, respectively, of the same spatial location between two TRDs. The exterior of the TRDs in Fig. 4a and b are indicated by the orange line in the schematic of Fig. 4c. The image highlights that these non-twin-related random GBs at the exterior of the TRD are typically susceptible to IGC. In order to understand how IGC propagates into the TRD, it is important to explore the triple junctions along the exterior of the TRD. Figure 4 shows 14 triple junctions along the TRD exterior. All triple junctions at TRD exterior contain two random GBs and one twin-related GB. The IGC connects through the random GBs belonging to both adjacent triple junctions. In 9 of 14 triple junctions, the 3rd GB is a coherent twin. At these triple junctions, IGC propagation into the TRD is promptly arrested at the coherent twin GBs. The remaining 5 of the 14 triple junctions contain one of either a high-order twin GB (Σ3n n > 1) or a Σ3 non-coherent twin. At these triple junctions, IGC is observed to propagate into the interior of the TRD.

Fig. 4
figure 4

a SEM image after IGC where corroded GBs show visible attack along all GBs at the TRD exterior. b Corresponding inverse pole figure colored map with GB type overlaid at same location in a. c Diagram illustrating that IGC is continuous along all the TRD exterior GBs. Scale bar is 50 µm

While IGC is observed to propagate into TRDs through susceptible higher-order Σ3n (n > 1) or non-coherent Σ3 twins, Fig. 5 highlights how propagation is typically arrested inside the TRD at a triple junction containing two coherent twins. Figure 5 further illustrates how the propagation continues through most of the higher-order twin-related GBs. In Fig. 5, IGC propagates first through the GB labeled A1 which is a Σ81d, 60.1° <4 4 3> GB. IGC attack continues into the TRD through several other GBs labeled A2 through A7, which includes Σ81d, Σ27a, and Σ9 GBs. In this example, IGC is continuous through a series of six triple junctions that contain two Σ3n (n > 1), which are not corrosion resistant, and one corrosion-resistant coherent twin boundary. As described above, the continuous IGC attack is stopped when it reaches a triple junction containing two coherent Σ3 GBs labeled A8. Figure 5 also shows clear IGC on a non-coherent twin segment which is labeled A9. From this example, which is representative of TRDs in the GBE condition, triple junctions that contain two coherent twins are shown to be highly effective in stopping IGC propagation.

Fig. 5
figure 5

a SEM image after IGC where corroded GBs show visible attack. b Corresponding inverse pole figure colored map with GB type overlaid of same location as a. c Diagram illustrating that IGC is continuous along TRD exterior GBs and has a continuous connectivity into the TRD interior at a number of higher-order twin GBs (A1–A7) until reaching a triple junction with two coherent twins (A8). Scale bar is 25 µm

Since every unique orientation and subsequently every Σ3n GB relationship is identified in the TRD and twinning tree (i.e., Fig. 1), it is possible to explore if all higher-order twin relationships are susceptible to IGC. It is found that during the GBE process and multiple twinning, two low-angle twin-related GBs, Σ243c (12.2° <311>) and Σ243i (7.36° <110>), can form in the GB network. Figure 6 provides one example for the Σ243i GB in which IGC propagation is arrested. While this is a different TRD than shown in previous examples, it clearly illustrates that low-angle GBs are both created by multiple twinning and are typically resistant to IGC. In Fig. 6, IGC propagation is seen at GBs labeled B1 and B2 inside the TRD which are Σ27a and Σ81d GBs, respectively. The IGC propagation stops when reaching the triple junction that contains GBs labeled B6 and B3, which are a coherent twin and a Σ243i low-angle GB, respectively.

Fig. 6
figure 6

a SEM image after IGC where corroded GBs show visible attack. b Corresponding inverse pole figure colored map with GB type overlaid of same location as a with GB labeled B1–B6, illustrating that IGC can be arrested at particular low-angle GBs (B3) that form during multiple twinning. Scale bar is 10 µm

While IGC propagation is typically arrested within the TRD, scenarios exist in which IGC can fully propagate throughout the TRD. Figure 7 provides an example where IGC continuously exists throughout a significant section of the TRD shown in Fig. 1. In this example, all the GBs are higher-order high-angle twin-related GBs. Subsequently, all interconnected triple junctions in this case have two high-angle Σ3n (n > 1) relationships. The IGC is continuous along GBs labeled C1, C2, and C3 which are Σ243e, Σ243a, and Σ729b. In this scenario, IGC propagates throughout the TRD as it passes through a number of triple junctions that contain one coherent twin that is corrosion resistant and two higher-order twin relationship that are not corrosion resistant.

Fig. 7
figure 7

a SEM image after IGC where corroded GBs show visible attack. b Corresponding inverse pole figure map with GB type overlaid of same location in a with GBs labeled C1–C3. c Diagram illustrating continuous IGC can occur through the width of a TRD where Σ243e, Σ243a, and Σ729b are all higher-order twins but still susceptible to IGC. Scale bar is 20 µm

To illustrate the level of IGC on higher-order twin GBs, Table 3 provides the percentage of corroded GBs by number fraction. It provides a simplified view on the GB character level of corrosion observed in the higher-order twins (Σ9 and Σ27) and compares these values to non-twinned random low-angle GBs (<15° misorientation) and random high-angle GBs. The level of corrosion observed between the Σ9, Σ27, and random high-angles GBs are nearly equivalent with percentages of corrode GBs between 92 and 95%. Therefore, under the sensitization and corrosive environments conditions explored in this study, Σ9 and Σ27 GBs do not help in regard to IGC resistance inside the TRD and corrode at a rate equivalent to random GBs. Only 22% of the random low-angle GBs corrode on average. This provides further validation that the observed twin-related low-angle GBs, Σ243c and Σ243i, are likely corrosion resistant because of their low misorientation angle.

Table 3 Overview of the number percentage of GBs corroded observed at Σ9, Σ27, random high-angle GBs, and random low-angle GBs

Microchemistry at susceptible grain boundaries

The formation of Cr-rich carbides and subsequent Cr-depleted zones along GBs during sensitization is the primary factor in the reduced ability to form a continuous passive and protective oxide. To verify the GB microchemistry and precipitation, STEM-EDS was completed to illustrate the formation of Cr-rich phases along susceptible GBs. Figure 8a and b indicates the microchemistry and precipitation behavior of two random high-angle GBs from the SA condition in the 1 h and 50 h sensitized condition, respectively. STEM-EDS results indicate the formation of a Cr and Mo-rich phase along random GBs after the 1 h condition. The 50 h sensitization condition indicates the formation of larger Cr-rich carbides consistent with M23C6 formed along random GBs. Selected area diffraction, shown in Supplementary Fig. S1, confirms the structure of the GB precipitate as a Cr-rich M23C6 phase. These large Cr-rich precipitates and the subsequent Cr-depletion zone formed is the primary cause for the increased corrosion rates and DOS observed in the bulk testing described above.

Fig. 8
figure 8

Overview grain boundary microchemistry and carbide precipitation at a random high-angle GB in the SA condition for the a 1 h sensitized and b 50 h sensitized condition. Scale bar in a and b are 30 and 100 nm, respectively

Discussion

Correlating TRD statistics to IGC

The results indicate that IGC has a systematically different response at locations at the exterior and interior of a TRD. In the interior of TRDs, triple junctions containing twin-related low-angle GBs and coherent twins arrest IGC propagation. At the exterior of the TRDs, the random GB network was typically shown to be susceptible to IGC propagation. These observations are in general agreement with Cayron,28 which showed that TRDs are an important microstructural entity since all grains within the TRD are linked to a resistant Σ3 GB. Therefore, intergranular phenomena such as IGC propagates between adjacent TRDs since it is typically arrested in the interior of TRDs. Since the corrosion propagation is shown to occur between adjacent TRDs, it is important to evaluate heavily twinned microstructures based on representative TRD statistics.

We propose that TRD statistics between different TMP conditions can provide insight into indicating IGC susceptible and resistant microstructures. This was highlighted by the vastly different bulk IGC behavior shown in the SA and GBE conditions. During the GBE TMP process, the size of the TRD, evaluated by TRD statistics by the average diameter (396 µm) and number of unique orientations (14.1), grows significantly from the SA state as shown in Table 2. Under the assumption that IGC propagation is eventually arrested inside the TRD, a microstructure with large TRDs, such as those found in GBE conditions, will be more IGC resistant than a microstructure with small TRDs. Since corrosion propagation occurs around the TRD, the TRD size is proposed to be an effective descriptor of the overall IGC resistance. Figure 3e and f highlights this difference in predictive IGC behavior between GBE and non-GBE conditions due to the size difference of the TRDs. It is conspicuous that as the TRD size increases, the propagation distance for continuous percolation of IGC increases. As described in our previous work,23 a larger TRD to grain size ratio is proposed to provide a microstructure with spatially large TRDs and smaller twin-related GBs within the TRD. The GBE condition, with a three-fold increase TRD to grain size ratio, compared to the SA shows dramatically improved bulk IGC behavior. The observation that TRD size plays a critical factor in predicting IGC behavior is in agreement with grain cluster analysis of GBE and non-GBE Alloy 690 tube by Xia et al.37 where they observe increased weight loss after IGC with small grain clusters associated with non-GBE condition compared to large GBE grain clusters.

As detailed above, we propose that TRD size and subsequent statistics provide the appropriate length scale and microstructural descriptor in correlating TMP conditions and IGC phenomena. Further efforts are required to fully confirm the applicability using different TMP condition TRD statistics as an effective descriptor IGC phenomena. For example, a number of other microstructural parameters have been used to correlate IGC phenomena with microstructural features including a decrease in the maximum random boundary connectivity.38 Furthermore, previous studies39,40 have indicate that there is a correlation between IGC phenomena measured by DOS and effective grain boundary energy (EGBE). EGBE is able to account both for the fraction of CSL boundaries and grain size. To fully appreciate the TRD statistics, a detailed comparison on the various microstructural descriptors that have been used to understand and predict IGC is required.

Role of GB character in IGC

Numerous computation studies17,41,42,43,44,45,46,47,48 have indicated significant anisotropy in GB properties, including GB energy, free volume, and mobility as function of the full macroscopic GB character, including both the boundary misorientation and plane. One proposed key property related to IGC is the GB energy since sensitization and subsequent IGC along particular GBs is dependent on the nucleation and growth of M23C6 carbide.1,49,50 Olmsted et al.41 explored the GB energy landscape of 388 distinct GBs in pure Ni and observed significant variations for between coherent and non-coherent twin GBs. Specifically, they showed that the symmetric coherent twin (Σ3 <110> {111}) has extremely low GB energy of 0.06 J/m2, while all other asymmetric and symmetric GB planes of the Σ3 had significantly higher values, up to approximately 1 J/m2. The low GB energy corroborates the lack of any corrosion attack on coherent Σ3 GBs in our study. The large spread in GB energy in the Σ3 GB plane space is not observed in other GBE relevant GBs such as the Σ9 GB. Here, all observed symmetric and asymmetric Σ9 GBs have higher GB energy ranging from approximately 0.8 to 1.3 J/m2.41 The high overall GB energy for all Σ9 GBs with no sharp energy minimization cusp in pure Ni is consistent with our study. In our study, approximately 95% of Σ9 GBs indicated significant IGC attack after the 1 h sensitization and ASTM bulk corrosion test. Furthermore, the other two corrosion-resistant GBs examined besides the coherent twin GB were the low-angle twin-related Σ243c and Σ243i GBs likely have lower than average GB energy. Olmsted et al.41 showed gradual increasing GB energy from low to high misorientation angle GBs across all presented tilt and twist GBs.

It has been shown experimentally that M23C6 Cr-rich carbides and subsequent Cr-depletion regions exist along GBs in 304/304L and 316/316L alloys. Trillo et al.51,52 examined Cr carbide nucleation and growth in 304 type stainless steel and found extensive carbide growth on random high-angle GBs and incoherent twin GBs, while coherent twins provided resistance to carbide nucleation and growth. This observation is consistent with a number of similar studies in both stainless steel50 and Ni-based Alloy 60053 which indicated that coherent twin GBs are resistant to GB nucleation, while incoherent twins, Σ9, Σ27, and other higher-order twin relationships can subsequently form deleterious Cr-rich carbides and adjacent Cr-depleted zones. In this study, as shown in Fig. 8, the 50 h sensitization treatment clearly forms Cr-rich carbides along random GBs and subsequent Cr-depleted zones. The Cr-depleted zones can subsequently be linked to the reduced bulk IGC resistance of the SA condition which contains a higher density of random GBs and smaller TRDs compared to the GBE condition.

It is important to note that the uniformity or depth of corrosion attack is different between the GBs observed in the study. In this study, there was no separation between GBs as function of corrosion depth as boundaries were only considered to either be attacked or resistant to IGC. As observed in Fig. 5, it is apparent, however, that although GBs labeled A1 through A7 all have significant IGC, the attack depth is different as function of GB type. For example, GB A1 is a Σ81d 60.1° <4 4 3> GB which has qualitatively smaller corrosion depth attack compared to for example the Σ9 or Σ27a GBs labeled A3 and A4 in Fig. 5. Recent studies54,55 explored newer methods to examine three-dimensional effects of the GB network on corrosion or stress corrosion cracking propagation by focused ion beam (FIB) serial sectioning and three-dimensional electron backscatter diffraction (EBSD) and is planned for a future follow-up study. FIB cross-sectional and/or three-dimensional EBSD provide improved means to determine the full macroscopic GB description and localized GB network effects.

In conclusion, the objective of this work was to correlate and enhance the understanding of IGC phenomena observed in a GBE and SA condition with effective microstructural descriptors. It was shown that TRDs provide an effective microstructural descriptor to evaluate both individual GB-dependent corrosion propagation and overall IGC resistance. The following key finds from the study include:

  • Large TRDs (measured both by an effective diameter and number of unique orientation) such as those observed in the GBE condition are shown to be resistant to IGC. The link between an increase in TRD size (GBE condition) and improved corrosion resistance is observed in both bulk scale corrosion testing completed: DL-EPR and mass loss testing after sensitization in 316L.

  • IGC can propagate into the TRD and is only fully arrested at triple junctions containing two GBs of the coherent twins or the twin-related low-angle GBs (Σ243c and Σ243i).

  • Propagation of IGC does not stop at any higher-order twin GBs (Σ3n, n > 1) aside from the aforementioned two low-angle Σ35 GBs. This has important implications as IGC can propagate along triple junctions containing these higher-order twin boundaries without arresting.

  • Σ3 coherent twins are resistant to IGC while non-coherent twins behave like random high-angle GBs, which is consistent with past studies; these differences in IGC resistance are linked to the dramatically different atomic GB structure between the coherent and non-coherent twin GB.

Methods

To examine the role of GB character and TRDs on IGC, different TMP routes were developed to obtain both standard SA and GBE microstructures. AISI 316L stainless steel was obtained from Carpenter Technology (Reading, PA) in the mill-annealed state with a nominal chemical composition given in Table 1. As-received specimens were SA for 60 min at 1050 °C followed by a water quench. The GBE microstructure consisted of 5% rolling reduction of nominal 10 mm thick samples followed by a 1025 °C anneal in open air for 90 min and water quench.46 The GBE and SA microstructures were examined by EBSD with a TexSEM Laboratories orientation imaging microscopy (OIM®) system. GB length and number population of twin and twin-variant GBs (Σ3n) were calculated using the Brandon criterion for CSL GBs.56 The classification and distribution of triple junction types were determined by the type of GBs at the triple junction following the methods described in Rohrer et al.57 and Randle et al.9 using multiple large data sets of >50,000 total GB segments analyzed per condition. The types of GB at a triple junction were classified as random (R), Σ3 coherent (Σ3c), Σ3 non-coherent (Σ3i), Σ9, or Σ27. The distribution of triple junctions accounted for the coherency of the Σ3 GB described in detail by Wright and Larsen.58 Briefly, we used 2× the step size (2 µm) to define the maximum deviation between the reconstructed GB and GB segment and a 5° trace deviation between the reconstructed GB trace and the {111} GB trace. This method provides an estimate of whether the Σ3 GB is a coherent or non-coherent twin segment.

TRDs were examined following the procedures described by Reed27,29 and Cayron.28 Adjacent orientations were considered part of the same TRD if they were identified as having either a Σ3 or Σ3n (n > 1) relationship with a maximum deviation from the ideal misorientation of 2°. Each orientation was given a grain “ID” to track the number of distinct orientations in the TRD. Adjacent grains with higher-order twin misorientation relationship (Σ3n, where n > 3) were considered part of the same twin domain. Therefore, by this classification of a TRD, GBs located along the exterior of the TRD were considered random GBs, while all GBs inside the TRD were considered twin-related GBs.

Site-specific boiling ferric sulfate-sulfuric acid IGC mass loss test, ASTM A262 Practice B,59 was carried on both sample conditions (GBE and SA) after both 1 h and 50 h 675 °C sensitization heat treatment in an open air box furnace environment, followed by air cooling. The ferric sulfate sulfuric acid test was completed in accordance with ASTM-A262-15 practices where sulfuric acid is in a solution of dissolved ferric sulfate in distilled water. Individual samples per condition with approximate size of 14 mm × 14 mm × 8 mm were placed in specialty made glass cradle and placed in the boiling solution. Three samples per condition were examined for bulk IGC corrosion rate for non-site-specific corrosion testing. Here, the sensitized samples of both the GBE and SA condition were examined for IGC corrosion rate (mm/yr) in accordance with ASTM A262B-15 at 120 h of testing using an analytical balance to measure loss in weight.

The DL-EPR test were also performed to obtain a bulk measure of the DOS between the 316L SA and GBE conditions. The procedures followed for the DL-EPR tests were similar to those followed by Srinivasan et al.30 Sensitized samples as described above were surface polished to a 1 µm diamond surface finish before testing and cleaned ultrasonically. A de-aerated 0.5 M H2SO4 + 0.01 M Potassium thiocyanate (KSCN) solution at room temperature was used as the test electrolyte for the DL-EPR tests. An electrochemical “flat cell” (manufactured by Princeton Applied Research) was used for electrochemical testing. The three-electrode configuration was used with the saturated calomel electrode (SCE) used as the reference electrode and a platinum mesh used as the counter electrode. The test electrolyte was de-aerated using Argon gas for 45 min prior to commencement of the electrochemical tests. The 316L specimens were firstly subject to cathodic cleaning in the test electrolyte by polarization at –1 VSCE for 2 min and then allowed to stabilize in the same electrolyte for 15 min. The specimens were then polarized from –0.45 VSCE to 0.3 VSCE in the anodic direction and then reversed at 0.3 VSCE back toward –0.45 VSCE in the cathodic direction. The scan rate used was 6 V/h. A peak current density was attained both during the forward scan (activation scan) and also the reverse scan (reactivation scan). The DOS can be estimated by Eq. 1, where Ir is the maximum current density on reactivation scan (reverse scan) and Ia is the maximum current density on the activation scan (forward scan).

$${\mathrm{DOS}} = \left( {\frac{I_{\mathrm{r}}}{I_{\mathrm{a}}}} \right) \times 100.$$
(1)

To carry out the site-specific IGC testing, both SA and GBE specimens were vibropolished perpendicular to the rolling direction and labeled with fiducial marks on the surface; SEM-EBSD analysis was completed in the area of interest before IGC. The remaining sample faces were prepared to a 600 grit (P1200) surface finish. Following 24 h of IGC testing, SEM was used to examine the regions of interest from the pre-IGC EBSD area surrounding the fiducial marks. The pre-corrosion EBSD region was used to allow a comparison of the character of GBs that were corroded.

Samples for scanning transmission electron microscopy (STEM) were prepared from the SA as-sensitized 1 and 50 h, condition. GB site-specific samples were prepared by standard FIB cross-sectional lift-out methods in a FEI Stratus DB235 FIB/SEM. Site-specific GBs were determined in the FIB/SEM by determining the GB character by EBSD. STEM-energy dispersive X-ray spectroscopy (EDS) maps and line scans were completed using either a FEI Talos F200X field-emission analytical TEM/STEM at 200 kV or a JEOL 2100 field-emission analytical microscope. For EDS, only Fe, Cr, Ni, Si, Mo were considered during analysis as C cannot be accurately quantified by EDS analysis.60

Data availability

The data that supports the results of this study can be made available from the corresponding author upon reasonable request.