Abstract
The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla.
Similar content being viewed by others
Introduction
Root-knot nematodes (Meloidogyne spp.) are one of the most economically damaging genera of plant-parasitic nematodes in horticultural and field crops. They are distributed worldwide, infect more than 2000 plant species and reduce the global crop yields by approximately 5%1. The genus has more than 90 species, including the four Meloidogyne species of M. hapla, M. incognita, M. javanica and M. arenaria, which are major pests worldwide2. Northern root-knot nematode (M. hapla) has a broad range of hosts and reproduces on tomato, potato, carrots, alfalfa, onion and many other plants, which causes substantial reduction of crop yield and quality3,4. M. hapla can presumably withstand colder temperatures and can occasionally be found in the cooler upland tropics5, in contrast, the other three species were adapted to areas with high temperatures. In China, this species has been found in more than 10 provinces6, and the distribution range is increasingly widespread.
Traditionally, identification of Meloidogyne species had been performed based on morphological characters of second-stage juveniles, perineal patterns of adult females7 and isozyme phenotypes8. Isozymes are highly reliable for identifying the root-knot nematode, but measurement of isozymes requires examining of adult females as well as considerable skills, furthermore, it is time-consuming9. Many different DNA-based methods have been reported for the identification of a large number of Meloidogyne spp10. Random amplified polymorphism DNA (RAPD) was used to distinguish M. hapla from other root-knot nematodes11. Species-specific sequence-characterized amplified region (SCAR)12, satellite DNA13, ribosomal DNA14,15,16,17 and high-resolution melting curve (HRMC)18 were also employed for the detection of M. hapla.
The loop-mediated isothermal amplification (LAMP) assay, originally developed by Notomi et al.19, is a simple and rapid method that allows DNA amplification under isothermal conditions. The technique can amplify DNA with high specificity and sensitivity under isothermal conditions within 1 hour based on the auto-cycling strand displacement DNA synthesis by Bst DNA polymerase19. LAMP utilizes four specific primers that were designed by six different regions of the target gene. The LAMP assay does not require much technical skill but a thiermal cycler. Additionally, the LAMP product can be seen with the naked eye by adding SYBR Green I, according to the colour change and the lateral flow dipstick (LFD). Because it is high efficient and does not require special laboratory facilities, this assay has recently shown promising in the specific and rapid detection of clinical20,21 and agricultural pathogens22,23,24. However, in plant parasitic nematodes, only Bursaphelenchus xylophilus25, M. enterolobii9, M. incognita26 Radopholus similis27 and Tylenchulus semipenetrans28 have been detected by LAMP. In this study, we established a sensitive and specific LAMP method for the direct detection of M. hapla from infected plant root galls based on the rDNA-ITS.
Results
Primer design and reaction optimization
The specific primers were designed for LAMP based on the sequence dissimilarity among M. hapla and other closely related Meloidogyne species at the primer positions, and the primer sets with high efficiency and low false positive rate were selected (Fig. 1 and Supplemental Table 1). The LAMP reaction was optimized under the conditions of 5.0 mmol∙L−1 Mg2+ and 2.4 mmol∙L−1 dNTPs, without betaine at 65 °C for 45 min.
Detection and confirmation of LAMP products
The LAMP products were detected by adding SYBR Green I fluorescence dye. After amplifications followed by adding SYBR Green I fluorescence dye, the tubes containing M. hapla samples produced positive reactions that the solution appeared green, while the solution remained orange in the negative reactions (Fig. 2A). The LAMP products were separated using two percent agarose gel electrophoresis, and the bands presented ladder-shaped characteristic (Fig. 2B). To eliminate the false positive interference, the LAMP reaction products were evaluated by lateral flow strips (LFD): the sample with positive amplification showed both control and test lines, whereas the negative control only displayed the control line (Fig. 2C).
Specificity of LAMP assay
Specificity of the LAMP was evaluated using 9 Meloidogyne species and 3 other plant nematodes (Table 1). The positive colour reactions were obtained with the DNA template from M. hapla, but were not observed in other nematode species (Fig. 3A). The LAMP amplifications were tested by LFD strips (Fig. 3B). The results indicated that the LAMP assay could distinguish M. hapla from closely related Meloidogyne species and other plant nematodes. The results were confirmed by an M. hapla-specific primer set, one band at 960 bp was detected in the four isolates of M. hapla (Fig. 3C).
Sensitivity comparison of LAMP with conventional PCR
A series of 10-fold dilutions of M. hapla DNA extracted from a single adult female were used to determine the sensitivity of the LAMP assay. Positive results were observed when at least 1 μl of the lysate was in the reaction mixture (that is, 5 × 10−5 of an adult female in the reaction mixture) (Fig. 4A,B). In a comparative analysis of the LAMP and conventional PCR assays, the LAMP assay was 100-fold higher sensitivity than the conventional PCR, which had a detection limit of 5 × 10−3 of single adult female lysates (Fig. 4C). No amplification was observed in the no-template control.
LAMP analysis combined with FTA Technology
To prove the applicability of the FTA-LAMP assay for direct M. hapla detection from plant root galls, two different methods were compared using the DNA extracted from a single root gall. The FTA-based assay presented similar results to the conventional DNA isolation method (Fig. 5), indicating that the FTA technology has the potential to be used for detection of plant nematodes combine with the LAMP assay.
Field evaluation of LAMP in infested plant root galls
For the artificially inoculated plant root, 19 of the 20 (95%) replicated LAMP reactions occurred a positive result using M. hapla induced galls, whereas with the same crude DNA extracts, only 16 of the 20 (80%) samples were successfully amplified by PCR assay. The negative results were observed from other closely related Meloidogyne species induced galls and healthy roots (Table 2). Furthermore, positive results were presented in 6 of the 42 field samples using FTA-LAMP with detection rates of 100% (Fig. 6 and Supplemental Table 2). The results were confirmed by rDNA-ITS and morphological observation. In the negative samples, although there were other Meloidogyne species, no M. hapla specimens were detected.
Discussion
M. hapla has a wide range of hosts, and can be distributed in various climate areas29. However, a rapid and precise diagnosis method is urgently required. Molecular techniques can help species identification, but all current techniques have limitations. Traditional M. hapla detection assays based on PCR methods11,12,13,15,30 are time-consuming and require sophisticated equipments as well as expertise. LAMP is a novel, simple, rapid and precise amplification method that can be adapted for diagnosing plant-parasitic nematodes, as previously reported9,25,26,27,28. In this study, we designed a set of five specific LAMP primers to detect M. hapla. The reaction can be completed in a water bath, and the amplified products can be detected visually by the naked eye rather than expensive instruments within 1 hour. Niu et al.26 developed a universal LAMP set (RKN-LAMP) that could be used to detect four common Meloidogyne species (M. incognita, M. arenaria, M. javanica and M. hapla), and M. incognita-specific LAMP set (Mi-LAMP), however, the M. hapla-specific LAMP assay was not recorded. In our study, the specific LAMP assay for detection of M. hapla was developed.
Several specific primers of M. hapla have been developed based on the ribosomal intergenic spacer (rDNA)10,15,16 and RAPD patterns12. Zijlstra et al.14 cloned and sequenced the ITS regions and found sufficient variability in those regions to separate M. hapla from M. chitwoodi. Then, the PCR primers were designed to separate M. chitwoodi, M. fallax, M. hapla, and M. incognita based on the ITS sequences11. In this study, we designed a set of five specific LAMP primers for M. hapla based on the ITS regions. LAMP based on these five primers is more specific compared to the conventional PCR pair-primers. Furthermore, the LFD strips were a great improvement to specificity and effectively avoided presenting false positives in the reactions. Additionally, the positive results were only present in four populations of M. hapla but did not appear in the other eight closely related Meloidogyne species, the test showed high specificity, but we tested a limited number of nematodes populations and did not assess other related species such as M. chitwoodi and M. fallax. Even the primers used in this study were selected in the ITS regions where there exist differences between M. hapla and other Meloidogyne species (Fig. 1) and had high specificity to avoid the risk of misdetection. More isolates of M. hapla and other related species should be examined using the LAMP method in the future.
Previous results found that the sensitivity of the LAMP assay was higher than conventional PCR9,26,27,28. In the present study, the detection limit was low to 1/200 000 nematode DNA, whereas the conventional PCR approach usually requires a single nematode, Williamson et al.11 designed the RAPD primers and Zijlstra et al.12 described the SCAR assay for the detection of M. hapla. The minimum amount of DNA that could be detected was a single juvenile nematode. In this study, pair-primers F3 and B3 were used for conventional PCR to detect M. hapla, and the sensitivity was 1/2000 nematode DNA (Fig. 4). Therefore, the detection limit of the LAMP was 100 times higher than that of PCR-based detection methods. The sensitivity of the LAMP was equal to B. xylophilus25, M. enterolobii9, M. incognita26, R. similis27 and T. semipenetrans28.
In a previous study, isolating nematodes from a Baermann funnel or direct picking nematodes from plant root galls required more time and specialized technique. The direct detection of plant nematodes using DNA from infected plant tissues has been published27,31,32,33,34, although those methods for preparing nucleic acids require toxic reagents and expansive instruments. In this study, direct extraction of DNA from plant root galls greatly improved the efficiency when using the FTA technology. This assay rarely reported in molecular plant nematology was not time-consuming and is using a nontoxic reagent. Marek et al.35 developed an FTA-based technology for the collection, long-term archiving and molecular analysis of three species of nematodes, including Ditylenchus dipsaci, Heterodera schachtii and M. hapla that involved PCR amplification. Our study demonstrated that the LAMP assay combined with FTA technology was fully applicable to plant nematode detection as well as the established conventional methods (Fig. 5). To the best of our knowledge, this is the first evidence of detecting plant nematodes using the LAMP assay combined with FTA technology, and the total detection time was shortened to one hour.
To evaluate the practical application of the FTA-LAMP for analyzing infected root galls, this method was tested on a collection from both artificially inoculated samples and field root galls. For artificially inoculated samples, 19 of the 20 (95%) M. hapla-induced root galls were successfully amplified. In contrast, only 16 of the 20 (80%) samples were successfully detected by PCR assay. Subsequently, the validity of the FTA-LAMP assay for M. hapla detection was also performed in 42 field samples (Fig. 6). All of the root galls infested with M. hapla were successfully detected by the FTA-LAMP assay with a detection rate of 100%, which indicated the high potential of this method. Combined with similar observations from previous reports9,25, these results showed that this assay has great stability and sensitivity, and can overcome interference from various types of PCR inhibitors, such as humic acid, proteins and non-target DNA. Furthermore, the FTA-captured nematode DNA could be stored at room temperature for many years35, which means that the field samples could be collected and that DNA purification could be accomplished using the FTA protocol; then, those samples could be tested with the LAMP assay, which it is simple, rapid and reliable.
In conclusion, the present study developed a FTA-LAMP assay for M. halpa detection. This novel FTA-LAMP assay could easily be used as a more sensitive, specific, and practical method for directly detecting M. halpa in infected plant tissues compared to previous methods. It will be potentially useful for monitoring and managing of M. halpa in the field.
Materials and Methods
Biological materials
Nine Meloidogyne species and three other plant nematode species used in this study are listed in Table 1. M. mali and M. camelliae were intercepted by China entry-exit Inspection and Quarantine in imported plant material, M. graminicola were collected from Myanmar and China. All Meloidogyne species except M. graminicola were purified from single egg-mass and reared on the susceptible tomato cv. Jiafen No. 9. The M. graminicola was cultured on the Rice cv. Nipponbare. Non-Meloidogyne genus including Pratylenchus coffeae, D. destructor and H. glycines were collected from China and used to verify the specificity test. All populations had been identified and previously diagnosed by morphological characteristics, rDNA-internal transcribed spacer (ITS) and species-specific primers11,12. Detailed protocols were described as below.
DNA extraction
The genomic DNA of nematode was extracted by two different methods, and a portion of the samples was completed as described in Ou et al.36. Another group of samples and root galls was isolated by an FTA card (Whatman, GE Healthcare, USA) using a process that as previously described35, the root gall was placed on the FTA card and crushed with a pestle, a 2 mm diameter piece of the FTA card containing biological material was manually isolated and transferred into a tube, the disk was washed with FTA purification solution (Whatman, GE Healthcare, USA) and Tris-EDTA (TE) buffer (10 mM Tris and 0.5 mM EDTA [pH 8.0]) and air dried, the disk was directly used as a template for LAMP amplification.
PCR amplification
Primers for rDNA-ITS amplification were rDNA1 and rDNA237, a M. hapla specific SCAR primer11,12 were used to evaluate the specificity of the LAMP assays (Supplementary Table 1). The LAMP outer primers (Mh-F3/B3) were used to detect the sensitivity of traditional PCR. Amplification was performed in a 25 μl reaction volume with 0.4 μmol each of forward and reverse primers (Mh0F/Mh1R and Mh-F3/Mh-B3, Supplementary Table 1), 2.5 μL 10×PCR buffer (TaKaRa), 2 μL dNTPs, 1U ExTaq, and 1 μL of DNA template, double distilled water added for a final volume of 25 μL. The amplification was carried out under the following cycling conditions: 94 °C for 5 min, then 35 PCR cycles of 94 °C for 30 second, 55 °C for 30 second, 72 °C for 30 second and final incubation at 72 °C for 10 min.
Design of LAMP Primers
Sequences of the rDNA-ITS were selected as the candidate targets for LAMP primer design. The M. hapla rDNA-ITS sequences amplified in this study (GenBank accession No. JX024147 and JX024148) and the sequence of other related species including M. minor (GU432775.1), M. graminicola (HM623442.1), M. incognita (JQ405212.1), M. arenaria (AF387092.1), M. javanica (AY438555.1), M. enterolobii (JF309153.1), M. hispanica (JX885741.1), M. chitwoodi (JN157868.1) and M. fallax (JN157869.1) were downloaded from Genbank at the NCBI website and used to compare the diversity of the rDNA-ITS sequence of Meloidogyne populations by MEGA5.038. The specific primers of LAMP were designed using the Primer Explorer V4 software (http://primerexplorer.jp) according to the rDNA-ITS sequence difference regions. Five primers were constructed: two outer primers (F3 and B3), a forward inner primer (FIP), a backward inner primer (BIP) and a loop backward primer (LB). FIP comprised the F1c sequence complementary to the F1 and F2 sequence. BIP consisted of the B1c sequence complementary to the B1 and B2 sequence (Fig. 1 and Supplementary Table 1).
Optimization of the LAMP reaction
The LAMP reaction was performed according to the protocol published previously19 with a minor modification. In a brief, the procedure used a 25 μL LAMP reaction mixture containing 1.4 μM each of the inner primers FIP and BIP, 0.2 μM each of the outer primers F3 and B3, 0.8 μM of the LF primer (forward loop primer), (0, 0.4, 0.8, 1.2, 1.6, 2.0, 2.4 mM) of a dNTPs mix, (2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 mM) MgSO4, (0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6 M) betaine, 8U of Bst DNA polymerase (New England Biolabs GmbH, USA), 2.5 μL of 10×Thermopol reaction buffer (20 mM Tris-HCl (pH 8.8, 25 °C), 10 mM KCl, 10 mM (NH4)2SO4, 2 mM MgSO4, 0.1% Triton X-100), 1 μL of genomic DNA solution, and double distilled water was added to reach a total volume of 25 μL. The reaction mixture was incubated at 60–65 °C for 30–90 min and terminated by incubating at 80 °C for 5 min. In this study, the concentrations of Mg2+, dNTPs, betaine and the reaction times were optimized.
Analysis of LAMP products
The LAMP amplification results were detected with three methods: adding the fluorescent dye SYBR green I (Invitrogen, 1:1000 TE buffer) to the reaction mixture and visually inspecting the results with the naked eye or under UV light; a Lateral-flow dipstick (LFD) assay that as visually observed with naked eyes, and 2% agarose gel electrophoresis.
Lateral-flow dipstick (LFD) assay
In the LAMP-LFD assay, the 5′ biotin-labeled inner primer FIP was used. A DNA probe labelled by FITC at the 5′ end was designed from the sequence between the F3 and B3 regions, and the other primers were designed using the same procedure as previously described (Supplementary Table 1). After the LAMP reaction, 4 μl of the FITC-labeled probe (20 pmol/μL) were added into the LAMP reaction solution and incubated at 63 °C for 5 min to hybridize. Then, 8 μl hybridized product was transferred into 100 μl assay buffer in the reaction well. The LFD Strip (Milenia Biotec, Germany) was dipped into the mixer for approximately 5 min to detect the amplicon-probe hybrid; the positive result showed a test line and a control line, whereas the negative control only had a control line.
Specificity and sensitivity comparison of LAMP to conventional PCR
To detect specificity of the LAMP assay, genomic DNA isolated from several Meloidogyne spp. and other plant nematode species was compared (Table 2). Meanwhile, a set of M. hapla-specific PCR primers Mh-0F and Mh-1F were used to verify the accuracy of the LAMP assay12. Specificity tests were repeated three times.
To determine the LAMP sensitivity, a series of 10-fold dilution of single female M. hapla genomic DNA (100, 10−1, 10−2, 10−3, 10−4, 10−5 and 10−6) was prepared and used for both the LAMP and traditional PCR assays. SYBR Green I dye and electrophoresis were used to detect the LAMP products. Sensitivity tests were repeated three times.
Detection of M. hapla in artificially inoculated plant root galls
The susceptible tomato cv. Jiafen No. 9 seeds were plated in the 15 cm diameter pots containing autoclaved soil and cultured in an environment-controlled chamber at 25 °C and a 16-h light/8-h dark cycle. Four weeks after seeding, the roots were inoculated with M. hapla, M. incognita, M. enterolobii, M. javanica and M. arenaria, individually, as described by Atamian et al.39. The rice Oryza sative L cv. Nipponbare was also planted in sand soil and inoculated with M. graminicola as described by Haegeman et al.40. Thirty days post inoculation (dpi), the single gall was collected and used to extract genomic DNA with FTA technology as described above. The healthy roots were used as negative control. Every sample was repeated twenty times.
Field evaluation of FTA-LAMP
To determine the practical application of the FTA-LAMP process in the field, 42 field samples, including root galls and soil in different regions across China, were collected and tested (Supplementary Table 2). DNA extraction from a single root gall by an FTA card and the LAMP reaction were performed as described above. The results were confirmed by both an rDNA-ITS assay as described by Vrain et al.37 and the morphological identification41. As a comparison, the purified DNA from M. hapla and sterilized water were used as positive and negative controls, respectively. Three independent tests were performed for each sample.
Additional Information
How to cite this article: Peng, H. et al. Rapid, simple and direct detection of Meloidogyne hapla from infected root galls using loop-mediated isothermal amplification combined with FTA technology. Sci. Rep. 7, 44853; doi: 10.1038/srep44853 (2017).
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
Sasser, J. N. Worldwide dissemination and importance of the root-knot nematodes, Meloidogyne spp. J Nematol 9, 26–29 (1977).
Moens, M., Perry, R. N. & Starr., J. L. In Root-knot Nematodes(ed. Perry R. N., Moens M., and Starr J. L. ) 1–17 (CAB International publishing, 2009).
Eisenback, D. J., Hunt, J. D. & Handoo,. A. Z. In Root-knot nematode(ed. Perry, R. N., Moens, M. & Starr, J. L. ) 18–50 (CAB International publishing, 2009).
Potter, J. W. & Olthof, T. H. A. In Plant parasitic nematodes in temperate agriculture(ed. Evans, K., Trudgill, D. L., Webster, J. M. )171–207 (CAB International publishing, 1993).
Brodie, B. B., Evans, K. & Franco, J. In Plant Parasitic Nematodes in Temperate agriculture(ed. Evans, K., Trudgill, D. L., Webster, J. M. ) 87–132 (CAB International publishing, 1993).
Meloidogyne hapla. [Distribution map]. Distribution Maps of Plant Diseases (2002).
Eisenback, J. D., Hirschmann, H., Sasser, J. N. & Triantaphyllou, A. C. A guide to the four most common species of root-knot nematode (Meloidogyne spp) with a pictorial key. Department of Plant Pathology, North Carolina State University and The United States Agency for International Development. North Carolina State Graphics, Raleigh.(1981).
Esbenshade, P. R. & Triantaphyllou, A. C. Use of Enzyme Phenotypes for Identification of Meloidogyne Species. J Nematol 17, 6–20 (1985).
Niu, J. H., Jian, H., Guo, Q. X. & Guo Y. D. Evaluation of loop-mediated isothermal amplification (LAMP) assays based on 5S rDNA-IGS2 regions for detecting Meloidogyne enterolobii . Plant Pathol 61, 809–819, doi: 10.1111/j.1365-3059.2011.02562.x (2012).
Blok, V. C. & Powers, T. O. In Root-knot Nematodes(ed. Perry, R. N., Moens, M. & Starr, J. L. ) 98–118 (CAB International Publishing, 2009).
Williamson,. V. M., Caswell-Chen, E. P., Westerdahl, B. B., Wu, F. F. & Caryl, G. A PCR Assay to Identify and Distinguish Single Juveniles of Meloidogyne hapla and M. chitwoodi . J Nematol 29, 9–15 (1997).
Zijlstra, C. Identification of Meloidogyne chitwoodi, M. fallax and M. hapla Based on SCAR-PCR: A Powerful Way of Enabling Reliable Identification of Populations or Individuals that Share Common Traits. Eur J Plant Pathol 106, 283–290, doi: 10.1023/A:1008765303364 (2000).
Castagnone-Sereno, P., Esparrago, G., Abad, P., Leroy, F. & Bongiovanni, M. Satellite DNA as a target for PCR-specific detection of the plant-parasitic nematode Meloidogyne hapla . Curr Genet 28, 566–570, doi: 10.1007/BF00518170 (1995).
Zijlstra, C., Lever, A. E. M., Uenk, B. J. & Van Silfhout, C. H. Difference between ITS regions of isolates of root-knot nematodes Meloidogyne hapla and M. chitwoodi . Phytopathology 85, 1231–1237 (1995).
Wishart, J., Phillips, M. S. & Blok, V. C. Ribosomal Intergenic Spacer: A Polymerase Chain Reaction Diagnostic for Meloidogyne chitwoodi, M. fallax, and M. hapla . Phytopathology 92, 884–892, doi: 10.1094/phyto.2002.92.8.884 (2002).
Petersen, D. J. & Vrain, T. C. Rapid identification of Meloidogyne chitwoodi, M. hapla, and M. fallax using PCR primers to amplify their ribosomal intergenic spacer. Fund Appl Nematol 19, 601–605 (1996).
Petersen, D. J., Zijlstra, C., Wishart, J., Blok, V. & Vrain, T. C. Specific probes efficiently distinguish root-knot nematode species using signature sequences in the ribosomal intergenic spacer. Fund Appl Nematol 20, 619–626 (1997).
Holterman, M. H. M., Oggenfuss, M., Frey, J. E. & Kiewnick, S. Evaluation of High-resolution Melting Curve Analysis as a New Tool for Root-knot Nematode Diagnostics. J Phytopathol 160, 59–66, doi: 10.1111/j.1439-0434.2011.01859.x (2012).
Notomi, T. et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28, E63 (2000).
Lee, D. et al. Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid. PLoS One 10, e0122922, doi: 10.1371/journal.pone.0122922 (2015).
Polley, S. D. et al. Clinical Evaluation of a LAMP test kit for Diagnosis of Imported Malaria. J Infect Dis 218, doi: 10.1093/infdis/jit183 (2013).
Tsai, S. M. et al. Rapid and sensitive detection of infectious bursal disease virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick. J virol methods 181, 117–124, doi: 10.1016/j.jviromet.2011.09.002 (2012).
Kouguchi, Y., Fujiwara, T., Teramoto, M. & Kuramoto, M. Homogenous, real-time duplex loop-mediated isothermal amplification using a single fluorophore-labeled primer and an intercalator dye: Its application to the simultaneous detection of Shiga toxin genes 1 and 2 in Shiga toxigenic Escherichia coli isolates. Mol Cell Probes 24, 190–195, doi: 10.1016/j.mcp.2010.03.001 (2010).
Abd-Elsalam, K., Bahkali, A., Moslem, M., Amin, O. E. & Niessen, L. An Optimized Protocol for DNA Extraction from Wheat Seeds and Loop-Mediated Isothermal Amplification (LAMP) to Detect Fusarium graminearum Contamination of Wheat Grain. Int J Mol Sci 12, 3459–3472, doi: 10.3390/ijms12063459 (2011).
Kikuchi, T., Aikawa, T., Oeda, Y., Karim, N. & Kanzaki, N. A rapid and precise diagnostic method for detecting the Pinewood nematode Bursaphelenchus xylophilus by loop-mediated isothermal amplification. Phytopathology 99, 1365–1369, doi: 10.1094/phyto-99-12-1365 (2009).
Niu, J. H. et al. Rapid detection of Meloidogyne spp. by LAMP assay in soil and roots. Crop Prot 30, 1063–1069, doi: 10.1016/j.cropro.2011.03.028 (2011).
Peng, H. et al. Loop-mediated isothermal amplification for rapid and precise detection of the burrowing nematode, Radopholus similis, directly from diseased plant tissues. Nematology 14, 977–986, doi: 10.1163/156854112X638415 (2012).
Lin, B., Wang, H., Zhuo, K. & Liao, J. Loop-Mediated Isothermal Amplification for the Detection of Tylenchulus semipenetrans in Soil. Plant Dis 100, 877–883, doi: 10.1094/PDIS-07-15-0801-RE (2016).
Williams, O. K. J. In C. I. H. Descriptions of Plant-parasitic Nematodes Ch. 31 (1972).
Powers, T. O. & Harris, T. S. A Polymerase Chain Reaction Method for Identification of Five Major Meloidogyne Species. J Nematol 25, 1–6 (1993).
Hu, M. X., Zhuo, K. & Liao, J. L. Multiplex PCR for the simultaneous identification and detection of Meloidogyne incognita, M. enterolobii, and M. javanica using DNA extracted directly from individual galls. Phytopathology 101, 1270–1277, doi: 10.1094/phyto-04-11-0095 (2011).
Atkins, S., Manzanilla-López, R., Franco, J., Peteira, B. & Kerry, B. A molecular diagnostic method for detecting Nacobbus in soil and in potato tubers. Nematology 7, 193–202, doi: 10.1163/1568541054879539 (2005).
Rahman, S. A. et al. In planta PCR-based detection of early infection of plant-parasitic nematodes in the roots: a step towards the understanding of infection and plant defence. Eur J Plant Pathol 128, 343–351, doi: 10.1007/s10658-010-9656-3 (2010).
Peng, H. et al. Sensitive and Direct Detection of Heterodera filipjevi in Soil and Wheat Roots by Species-Specific SCAR-PCR Assays. Plant Dis 97, 1288–1294, doi: 10.1094/PDIS-02-13-0132-RE (2013).
Marek, M., Zouhar, M., Douda, O., Manasova, M. & Rysanek, P. Exploitation of FTA cartridges for the sampling, long-term storage, and DNA-based analyses of plant-parasitic nematodes. Phytopathology 104, 306–312, doi: 10.1094/phyto-03-13-0067-r (2014).
Ou, S. Q., Peng, D. L., Liu, X. M., Li, Y. & Moens, M. Identification of Heterodera glycines using PCR with sequence characterised amplified region (SCAR) primers. Nematology 10, 397–403, doi: 10.1163/156854108783900212 (2008).
Vrain, T. C., Wakarchuk, D. A., Levesque, A. C. & Hamilton, R. I. Intraspecific rDNA restriction fragment length polymorphism in the Xiphinema americanum group. Fund Appl Nematol 15, 563–573 (1992).
Tamura, K. et al. MEGA5: molecular evolutionary genetics analysis using maximum likelihood, evolutionary distance, and maximum parsimony methods. Mol Biol Evol 28, 2731–2739, doi: 10.1093/molbev/msr121 (2011).
Atamian, H. S., Roberts, P. A. & Kaloshian, I. High and low throughput screens with root-knot nematodes Meloidogyne spp. J Vis Exp: JoVE e3629, doi: 10.3791/3629 (2012).
Haegeman, A., Bauters, L., Kyndt, T., Rahman, M. M. & Gheysen, G. Identification of candidate effector genes in the transcriptome of the rice root knot nematode Meloidogyne graminicola . Mol Plant Pathol 14, 379–390, doi: 10.1111/mpp.12014 (2013).
Karssen, G. The plant parasitic nematode genus Meloidogyne Göldi, 1892 (Tylenchida) in Europe. (Brill Academic Publishers, 2002).
Acknowledgements
This study was supported by the National Basic Research Program of China (973 Program, Grant No. 2013CB127502), the Natural Science Foundation of China (31301646, 31672012) and the Special Fund for Agro-scientific Research in the Public Interest (No. 201103118). Profs. Ricardo Holgado (Norwegian Institute of Bioeconomy Research) and Prof. Shiming Liu (Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing and Southern Illinois University Carbondale) are thanked for their scientific advices and revising the manuscript.
Author information
Authors and Affiliations
Contributions
Conceived and designed the experiments: DLP. Analyzed the data and wrote the paper: HP HBL. Performed the experiments: HP WKH JKC. Contributed materials: LAK XQH JFG. Supervised the research: DLP. Gave assistance for writing: WKH JL.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Peng, H., Long, H., Huang, W. et al. Rapid, simple and direct detection of Meloidogyne hapla from infected root galls using loop-mediated isothermal amplification combined with FTA technology. Sci Rep 7, 44853 (2017). https://doi.org/10.1038/srep44853
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep44853
This article is cited by
-
Unveiling the potential of loop-mediated isothermal amplification (LAMP) for plant-parasitic nematode identification: a review
Journal of Plant Diseases and Protection (2024)
-
Development and evaluation of loop-mediated isothermal amplification assay for rapid and sensitive detection of potato cyst nematode, Globodera pallida from soil
3 Biotech (2023)
-
Common potato disease symptoms: ambiguity of symptom-based identification of causal pathogens and value of on-site molecular diagnostics
Journal of General Plant Pathology (2022)
-
Soybean cyst nematodes: a destructive threat to soybean production in China
Phytopathology Research (2021)
-
Rapid and sensitive detection of potato cyst nematode Globodera rostochiensis by loop-mediated isothermal amplification assay
3 Biotech (2021)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.