Article | Published:

A wearable pH sensor with high sensitivity based on a flexible charge-coupled device

Nature Electronicsvolume 1pages596603 (2018) | Download Citation

Abstract

Flexible chemical sensors could be used to create wearable devices that continuously monitor a variety of health conditions through the analysis of a person’s sweat. Current wearable pH sensors for sweat monitoring have a limited pH detection sensitivity at room temperature of about 59 millivolts per pH unit, which is determined by the Nernst equation. Here we show that a sensitive pH sensor can be created using a flexible charge-coupled device (CCD) and integrated with a temperature sensor. Our CCD-based pH sensor can, through accumulation cycles of electron charge transfer, achieve a sensitivity of around 240 millivolts per pH unit, which is roughly four times larger than the Nernst theoretical limit. Furthermore, the integrated flexible temperature sensor can be simultaneously used to compensate for the temperature dependence of the pH detection and to monitor skin temperature. As a proof of concept, we demonstrate that our CCD-based chemical sensor can be used to monitor the sweat pH and skin temperature of a person in real time.

Access optionsAccess options

Rent or Buy article

Get time limited or full article access on ReadCube.

from$8.99

All prices are NET prices.

Data availability

The data that support the finding of this study are available from the corresponding author upon reasonable request.

Additional information

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  1. 1.

    Cao, Q. et al. Medium-scale carbon nanotube thin-film integrated circuits on flexible plastic substrates. Nature 454, 495–500 (2008).

  2. 2.

    Kim, D. H. et al. Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy. Nat. Mater. 10, 316–323 (2011).

  3. 3.

    Someya, T. et al. Conformable, flexible, large-area networks of pressure and thermal sensors with organic transistor active matrixes. Proc. Natl Acad. Sci. USA 102, 12321–12325 (2005).

  4. 4.

    Wang, S. et al. Skin electronics from scalable fabrication of an intrinsically stretchable transistor array. Nature 555, 83–88 (2018).

  5. 5.

    Takei, K. et al. Nanowire active-matrix circuitry for low-voltage macroscale artificial skin. Nat. Mater. 9, 821–826 (2010).

  6. 6.

    Chen, H., Cao, Y., Zhang, J. & Zhou, C. Large-scale complementary macroelectronics using hybrid integration of carbon nanotubes and IGZO thin-film transistors. Nat. Commun. 5, 4097 (2014).

  7. 7.

    Honda, W. et al. High-performance, mechanically flexible, and vertically integrated 3D carbon nanotube and InGaZnO complementary circuits with a temperature sensor. Adv. Mater. 27, 4674–4680 (2015).

  8. 8.

    Choi, S., Lee, H., Ghaffari, R., Hyeon, T. & Kim, D. H. Recent advances in flexible and stretchable bio-electronic devices integrated with nanomaterials. Adv. Mater. 28, 4203–4218 (2016).

  9. 9.

    Chortos, A., Liu, J. & Bao, Z. Pursuing prosthetic electronic skin. Nat. Mater. 15, 937–950 (2016).

  10. 10.

    Gao, W. et al. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature 529, 509–514 (2016).

  11. 11.

    Kim, D. H. et al. Epidermal electronics. Science 333, 838–843 (2011).

  12. 12.

    Lee, H. et al. A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy. Nat. Nanotech. 11, 566–572 (2016).

  13. 13.

    Lee, H. et al. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module. Sci. Adv. 3, e1601314 (2017).

  14. 14.

    Park, J., Kim, M., Lee, Y., Lee, H. S. & Ko, H. Fingertip skin-inspired microstructured ferroelectric skins discriminate static/dynamic pressure and temperature stimuli. Sci. Adv. 1, e1500661 (2015).

  15. 15.

    Yamamoto, Y. et al. Printed multifunctional flexible device with an integrated motion sensor for health care monitoring. Sci. Adv. 2, e1601473 (2016).

  16. 16.

    Sekitani, T. et al. A rubberlike stretchable active matrix using elastic conductors. Science 321, 1468–1472 (2008).

  17. 17.

    Honda, W., Arie, T., Akita, S. & Takei, K. Printable and foldable electrodes based on a carbon nanotube-polymer composite. Phys. Status Solidi A 211, 2631–2634 (2014).

  18. 18.

    Kim, J. et al. Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin. Sci. Adv. 2, e1600418 (2016).

  19. 19.

    Cheng, Q. et al. Folding paper-based lithium-ion batteries for higher areal energy densities. Nano. Lett. 13, 4969–4974 (2013).

  20. 20.

    Hu, L. et al. Highly conductive paper for energy-storage devices. Proc. Natl Acad. Sci. USA 106, 21490–21494 (2009).

  21. 21.

    Bariya, M., Nyein, H. Y. Y. & Javey, A. Wearable sweat sensors. Nat. Electron. 1, 160–171 (2018).

  22. 22.

    Takei, K., Honda, W., Harada, S., Arie, T. & Akita, S. Toward flexible and wearable human-interactive health-monitoring devices. Adv. Healthcare Mater. 4, 487–500 (2015).

  23. 23.

    Sawada, K., Shimada, T., Ohshina, T., Takao, H. & Ishida, M. Highly sensitive ion sensors using charge transfer technique. Sens. Actuat. B 98, 69–72 (2004).

  24. 24.

    Hizawa, T., Sawada, K., Takao, H. & Ishida, M. Fabrication of a two-dimensional pH image sensor using a charge transfer technique. Sens. Actuat. B 117, 509–515 (2006).

  25. 25.

    Gao, W. et al. Wearable microsensor array for multiplexed heavy metal monitoring of body fluids. ACS Sens. 1, 866–874 (2016).

  26. 26.

    Nakata, S., Arie, T., Akita, S. & Takei, K. Wearable, flexible, and multifunctional healthcare device with an ISFET chemical sensor for simultaneous sweat pH and skin temperature monitoring. ACS Sens. 2, 443–448 (2017).

  27. 27.

    Bandodkar, A. J., Jeerapan, I. & Wang, J. Wearable chemical sensors: present challenges and future prospects. ACS Sens. 1, 464–482 (2016).

  28. 28.

    Imani, S. et al. A wearable chemical-electrophysiological hybrid biosensing system for real-time health and fitness monitoring. Nat. Commun. 7, 11650 (2016).

  29. 29.

    Akiyama, T., Ujihira, Y., Okabe, Y., Sugano, T. & Niki, E. Ion-sensitive field-effect transistors with inorganic gate oxide for pH sensing. IEEE Trans. Elect. Devices 29, 1936–1941 (1982).

  30. 30.

    Bousse, L. & Bergveld, P. The role of buried OH sites in the response mechanism of inorganic-gate pH-sensitive ISFETs. Sens. Actuat. 6, 65–78 (1984).

  31. 31.

    Nyein, H. Y. et al. A wearable electrochemical platform for noninvasive simultaneous monitoring of Ca2+ and pH. ACS Nano. 10, 7216–7224 (2016).

  32. 32.

    Lee, D. & Cui, T. Low-cost, transparent, and flexible single-walled carbon nanotube nanocomposite based ion-sensitive field-effect transistors for pH/glucose sensing. Biosens. Bioelectron. 25, 2259–2264 (2010).

  33. 33.

    Yan, C., Wang, J. & Lee, P. S. Stretchable graphene thermistor with tunable thermal index. ACS Nano. 9, 2130–2137 (2015).

  34. 34.

    Martin, A. et al. Epidermal microfluidic electrochemical detection system: enhanced sweat sampling and metabolite detection. ACS Sens. 2, 1860–1868 (2017).

  35. 35.

    Lee, Y. K. et al. Kinetics and chemistry of hydrolysis of ultrathin, thermally grown layers of silicon oxide as biofluid barriers in flexible electronic systems. ACS Appl. Mater. Interf. 9, 42633–42638 (2017).

Download references

Acknowledgements

This work was partially supported by a JSPS KAKENHI grant (17H04926), a JST PRESTO grant (JPMJPR17J5) and the TEPCO Memorial Foundation.

Author information

Author notes

  1. These authors contributed equally: Shogo Nakata, Mao Shiomi.

Affiliations

  1. Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, Japan

    • Shogo Nakata
    • , Mao Shiomi
    • , Yusuke Fujita
    • , Takayuki Arie
    • , Seiji Akita
    •  & Kuniharu Takei
  2. JST PRESTO, Kawaguchi, Saitama, Japan

    • Kuniharu Takei

Authors

  1. Search for Shogo Nakata in:

  2. Search for Mao Shiomi in:

  3. Search for Yusuke Fujita in:

  4. Search for Takayuki Arie in:

  5. Search for Seiji Akita in:

  6. Search for Kuniharu Takei in:

Contributions

S.N. and K.T. conceived the idea and designed the experiments. S.N., M.S., Y.F. and K.T. carried out the device fabrication and characterization. All authors contributed to analysing the data. K.T. wrote the paper and all authors provided feedback.

Competing interests

The authors declare no competing interests.

Corresponding author

Correspondence to Kuniharu Takei.

Supplementary information

  1. Supplementary Information

    Supplementary Figures 1–12

  2. Reporting Summary

About this article

Publication history

Received

Accepted

Published

DOI

https://doi.org/10.1038/s41928-018-0162-5

Further reading