Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Alpha-power in electroencephalography as good outcome predictor for out-of-hospital cardiac arrest survivors

Abstract

This study aimed to investigate the utility of quantitative EEG biomarkers for predicting good neurologic outcomes in OHCA survivors treated with targeted temperature management (TTM) using power spectral density (PSD), event-related spectral perturbation (ERSP), and spectral entropy (SE). This observational registry-based study was conducted at a tertiary care hospital in Korea using data of adult nontraumatic comatose OHCA survivors who underwent standard EEG and treated with TTM between 2010 and 2018. Good neurological outcome at 1 month (Cerebral Performance Category scores 1 and 2) was the primary outcome. The linear mixed model analysis was performed for PSD, ESRP, and SE values of all and each frequency band. Thirteen of the 54 comatose OHCA survivors with TTM and EEG were excluded due to poor EEG quality or periodic/rhythmic pattern, and EEG data of 41 patients were used for analysis. The median time to EEG was 21 h, and the rate of the good neurologic outcome at 1 month was 52.5%. The good neurologic outcome group was significantly younger and showed higher PSD and ERSP and lower SE features for each frequency than the poor outcome group. After age adjustment, only the alpha-PSD was significantly higher in the good neurologic outcome group (1.13 ± 1.11 vs. 0.09 ± 0.09, p = 0.031) and had best performance with 0.903 of the area under the curve for predicting good neurologic outcome. Alpha-PSD best predicts good neurologic outcome in OHCA survivors and is an early biomarker for prognostication. Larger studies are needed to conclusively confirm these findings.

Introduction

More than 250,000 people in the USA and Europe annually experience out-of-hospital cardiac arrest (OHCA)1,2 with only 8.3% of survivors having a favorable neurological outcome and being eligible for discharge2. Hypoxic-ischemic brain injury after the decision to withdraw life-sustaining therapy (WLST) is the leading cause of mortality, and accurate prediction of neurological outcomes is of utmost importance to guide the nature and duration of therapeutic interventions3,4. Recent recommendations proposed the strategy for predicting the neurological outcome based on a multimodal approach using clinical examination, electrophysiology, biomarkers, and brain imaging5,6,7.

Electroencephalography (EEG) is the most widely used and easily accessible tool to predict prognosis and detect subclinical seizures after cardiac arrest8. Although the standardized critical care EEG terminology proposed by American Clinical Neurophysiology Society (ACNS) and the standard EEG classification (highly malignant, malignant, and benign pattern), its clinical usability is limited by poor reproducibility and low inter-rater reliability even among experts9,10,11,12,13,14,15,16. Some specific EEG patterns or features were suggested for prognostication after cardiac arrest17,18, and various confounders including examination timing, the patient’s condition, and different sedatives or anesthetics used in these patients interfere with the objective identification of these features by visual inspection18,19. These limitations encourage the development of quantitative EEG biomarkers for neurologic outcome prediction in OHCA instead of expert interpretation.

To quantify the background EEG with standard recording, we analyzed the power, variability and randomness of each frequency band using the power spectral density (PSD), event-related spectral perturbation (ERSP), and spectral entropy (SE) in patients with OHCA treated with targeted temperature management (TTM). Finally, readily available and accurate quantitative biomarker for good outcomes was proposed with optimal cutoff values.

Results

Among 54 nontraumatic OHCA survivors who received TTM and underwent EEG, two and 11 patients were excluded due to poor ECG quality, periodic or rhythmic pattern, respectively. Thus, 41 patients were ultimately included in this study. Patients were categorized into the good (n = 21, 52.5%) and poor (n = 20, 47.5%) neurological outcome groups, respectively.

Demographic and clinical characteristics of patients

The demographic and clinical characteristics of the patients are summarized in Table 1. The patients in the good neurological outcome group were younger (mean, 51.9 vs. 65.2 years; P = 0.012) and more frequently male (85.7% vs. 50.0%; P = 0.014). The patients in the good neurological outcome group also showed higher frequency of witnessed arrest (85.6% vs. 50.0%; P = 0.014), initial shockable rhythm (85.7% vs. 30.0%; P < 0.001), and shorter resuscitation duration (median, 11.0 vs. 34.0 min; P = 0.022).

Table 1 Comparison of the clinical characteristics between the out-of-hospital cardiac arrest patients with good and poor neurologic outcomes at 1 month.

Visual analysis of extracted EEGs

Figure 1 shows examples of visual EEG analysis. Both patients in the good (right) and poor (left) neurologic outcome group showed symmetric, attenuated (all activities < 20 μV, 100% of record) background activities over whole record. There was no stage-II sleep transients or periodic rhythm. The dominant frequency and amplitude of background activities were difficult to differentiate between both patients in each group by visual analysis. In fact, the alpha-PSD values of this epoch in patients with poor (left panel) and good (right panel) neurologic outcomes were 0.06 and 3.07, respectively.

Figure 1
figure 1

Representative visual analysis of raw data. The visual analysis could not differentiate poor and good neurological outcome. Example of EEGs from patients with poor (left panel) and good (right panel) neurological outcomes. Top—EEG filtered with a 0.5-Hz high-pass filter with a sensitivity of 10 μV/mm. Middle—EEG filtered with a 14-Hz high-pass filter with a sensitivity of 5 μV/mm. Bottom—EEG filtered with a 30-Hz high-pass filter with a sensitivity of 5 μV/mm. The alpha-PSD values of this epoch in patients with poor (left panel) and good (right panel) neurologic outcomes were 0.06 and 3.07, respectively.

Quantitative analysis of extracted EEGs according to background frequency

PSD, ERSP, and SE were compared between the patients in the good and poor neurologic outcome groups to quantify the power, variability, and randomness of each frequency band (Table 2; Fig. 2). All and each frequency band-PSD of patients with good neurologic outcomes were significantly higher compared to that with poor neurologic outcomes (Table 2; Fig. 2A). Except for the delta frequency band, all and the rest frequency band-ERSP of the patients in the poor neurologic outcome group were lower than the patients in the good neurologic outcome group with statistical significance (Table 2; Fig. 2B). Moreover, all and each frequency band-SE of the patients with poor neurologic outcomes were significantly higher than patients with good neurologic outcomes (Table 2; Fig. 2C). Only alpha-PSD was significantly higher in patients with good neurologic outcomes than those with poor neurologic outcomes after adjusting the age of each patient (Table 2; Fig. 2A).

Table 2 Comparisons of quantitative analysis using PSD, ERSP, and SE of each frequency between the out-of-hospital cardiac arrest patients with good and poor neurologic outcomes at 1 month.
Figure 2
figure 2

Scattered dots of (A) PSD, (B) ERSP, and (C) SEs of all and each frequency. Small star, p < 0.05; Large start, age-adjusted p < 0.05 by linear mixed model.

Useful biomarkers for predicting neurologic outcomes

Among three values of all and each frequency band, the alpha-PSD was the most reliable biomarker to differentiate the neurologic outcomes with the area under the curve (AUC) of 0.903 and p value < 0.001. The alpha-PSD cutoff values of the averaged C3 and C4 electrodes were 0.14 with 82.4% sensitivity and 80.5% specificity or 0.20 with 72.4% sensitivity and 87.0% specificity, respectively (Fig. 3).

Figure 3
figure 3

ROC curve (blue line) and predictive values according to the cutoff of alpha-PSDs; under the curve (AUC) of 0.903 and p value < 0.001.

Discussion

In this study, we quantified the power, variability, and randomness of each frequency band in OHCA survivors with routine EEG to investigate the factor that can differentiate the good and poor neurological outcomes. We identify that the alpha-PSD was most reliable biomarker to indicate good neurologic outcomes with an AUC of 0.903.

Beyond the accurate description using Standardized Critical Care EEG Terminology, appropriate interpretation of these descriptions is essential for precise prognostication of neurologic outcomes in patients with OHCA. Among various background patterns defined in the Standardized Critical Care EEG Terminology, we found the dominant background frequency with alpha and theta waves were a powerful predictors (adjusted OR for favorable neurologic outcomes of 13.030) with high sensitivity (86.21%) and negative predictive value (91.30%) in our previous study20. However, the interrater variability is a challenging issue for neurologists and emergency physicians to accurately predict neurologic outcome and the agreement strength is decreased especially for background frequency interpretation21. In this study, the visual analysis of the EEG was also difficult to show the differences of predominant frequency between patients with poor and good neurologic outcomes even with time expansion with bandpass filter (Fig. 1). Thus, we focus the quantitative analysis to identify the power and dynamic changes of background brain oscillation according to each frequency band.

The brain has continuous neuronal oscillations even in resting-state and time-related variabilities and can reflect the subclinical brain dynamics during consciousness or unconsciousness. The ERSP has a strong ability to detect the time-related shift of the spectral powers from the baseline in a specific frequency22,23,24,25. Further, this analysis allows extracting information about the time course of power changes in each frequency under specific tasks including auditory stimuli, attention, and cognitive processes26,27 and hyperactive state of the brain with seizure or epileptic spasms in previous studies28,29.

Under steady-state condition, the neuronal firing is constantly occurred to transfer the information between neuron, and a synchronous state is maintained. The weakly correlated action potentials of individual neurons, for any reason, can lead to the asynchronous state and increase randomness30,31,32, entropy. The entropy algorithms have already been widely used in analyzing depth of anesthesia33,34 and detecting seizures35,36.

To identify the time-related variability and randomness of power in each frequency band, we calculate the ERSP and SE in this study, respectively. No significant differences of ERSP and SE in all frequencies between the groups after age adjustment indicated that the patients with OHCA had too low brain activities to measure the variability or randomness without external stimulation due to acute neuronal damage itself or treated sedatives.

The PSD analysis is a method for quantitatively evaluating the power distribution of target frequency ranges. The low amplitude of background activity of < 20 μV in the entire channels, including suppressed or attenuated EEG pattern, is classified as highly malignant or malignant EEG that predicts a poor neurologic outcome12. In these context, we quantify the background power of each frequency using PSD and identify that the powers of alpha frequency bands are increased in the good neurologic outcome group in line with previous studies12,37.

Regarding dominant background frequency, we are interested in alpha frequency band, which is related to the good neurological outcome in our previous and current studies20. Alpha oscillations are the salient features during resting or wakefulness, and the change of alpha frequency is related to aging, cognitive function, sensorimotor processing, sleep, and neurodegenerative disease including Alzheimer’s disease38,39,40. A recent study with OHCA patients reported that the unfavorable outcome group showed lower power spectra in around 10 Hz alpha frequency compared with the favorable outcome group41. Furthermore, another study found that the prominent alpha peaks were presented in patients with minimally conscious states and in none of the comatose patients42. Consistently, the power of alpha frequency is higher in the good outcome group than in the poor outcome group after adjustment by age and the most reliable biomarker to predict neurologic outcomes in patients with OHCA.

To our knowledge, this is first report that quantify the three characteristics of the dominant background frequency to predict neurologic outcomes in OHCA patients. The findings of the current study suggest that alpha-PSD can be used as simple and reliable biomarkers for prognostication of good neurologic outcomes. There were only few studies to predict the good neurologic outcome for OHCA patients and alpha-PSD could be one of the valuable and accurate biomarkers to predict good neurologic outcome20,43,44. The results of the current study should be interpreted in the context of the following limitations. The retrospective study design and associated selection bias may have influenced the results. Moreover, the limited number of patients may have contributed to the lack of significance of some results of the current study. Another potential concern is the EEG timing and influence of sedative agents during EEG recording. Additionally, we used the data of patients with continuous background, who potentially had less severe spectrum of anoxic injury. However, the use of sedative agents followed the postcardiac arrest care protocol in this experienced tertiary center, and a relative homogenous standard routine EEG protocol was used. In addition, the cohort of the current study is not complicated by the WLST issue due to forbidden by law in South Korea during the study period. This results mainly focused EEG biomarker and delicate applications with other prognostic factors in actual clinical field should be considered according to present guidelines45.

Considering the poor interrater agreement and reproducibility of the visual interpretation of standard intermittent EEG, the quantitative analysis method with PSD, ERSP, and SE feature extraction presented in this study suggests alpha-PSD as early prognostic tools for neurologic outcome in patients with OHCA. Further larger studies are warranted to validate the predictive value of the alpha-PSD of early standard intermittent EEG proposed in this study.

Methods

Study design and patients

This retrospective, observational, registry-based cohort study was conducted at the emergency intensive care unit (ICU) of a tertiary care university-affiliated teaching hospital in Korea. Data were extracted from the OHCA registry containing prospectively collected data of consecutive patients with OHCA since January 201046. The Institutional Review Board of the University of Ulsan College of Medicine, Seoul, Korea, reviewed and approved the study protocol (no. 2019-1883). Informed consent was waived due to the retrospective nature of the study by Institutional Review Board of the University of Ulsan College of Medicine, Seoul, Korea (no. 2019-1883). All experiments were performed in accordance with relevant guidelines and regulations.

This study included patients with successfully resuscitated nontraumatic OHCA > 18 years old and treated with TTM due to neurologic impairments after the return of spontaneous circulation (ROSC) between January 2014 and December 2018. Routine EEG was recorded in the first 48 h after ROSC. All patients were comatose during EEG recording and TTM. We excluded patients with poor EEG quality which is impossible to extract the representative 5-min EEG or periodic/rhythmic EEG pattern. The excluded periodic or rhythmic pattern were represented in supplementary Fig. 1. All patients were followed up to 1 month after cardiac arrest with neurologic assessment using the Cerebral Performance Category (CPC) score. The primary outcome of this study was a good neurologic outcome at 1 month, defined as CPC scores 1 and 2.

Management and data collection

All patients were treated according to the current advanced cardiac life support guidelines47,48. TTM was performed for all unconscious patients using Arctic Sun Energy Transfer Pad (Medivance Corp., Louisville, CO, USA), and the target temperature (33 °C or 36 °C) was maintained for 24 h. Patients were rewarmed at a rate of 0.25 °C/h after 24 h, following maintained normothermia until 72 h from ROSC. The temperature was monitored using an esophageal temperature probe. A combination of propofol, midazolam, fentanyl, remifentanil, and morphine was used for sedation and analgesia. A neuromuscular blocking agent was administered to control shivering if necessary. Patients with seizure activity on EEG were treated with valproate or levetiracetam. All patients received standard intensive care according to institutional protocol. WLST was legally prohibited in South Korea until August 201749, and none of the patients in the current study underwent WLST.

Demographic and clinical data, including age, sex, previous medical history, resuscitation profiles such as the presence of a witness on collapse, initial documented rhythm, and resuscitation duration) were obtained.

EEG recording and preprocessing

Standard EEG examination was started during TTM after ICU admission. The 30-min scalp EEG was recorded by the Stellate EEG system from 21 electrodes that were placed according to the international 10–20 electrode system (Fp1–2, F7–8, T7–8, P7–8, F3–4, C3–4, P3–4, O1–2, Fz, Cz, and Pz) with a sampling rate of 200 and 0.1 Hz high-pass filter. EEGs were initially reviewed to select clean data without apparent artifacts or muscle activities, and 5 min of each artifact-free resting-state EEG were collected. The extracted EEGs were extended temporally, and 0.5, 15, and 30 Hz high-pass filters were used to differentiate visible background amplitude and frequency, including beta (14–30 Hz) and gamma (30–100 Hz) with sensitivities of 10 and 5 μV/mm, respectively (Fig. 1). Before quantitative analysis, the data were preprocessed using the EEGLAB toolbox of MATLAB 2020a. The 0.5-Hz high-pass and 60-Hz notch filters were used to remove the alternating current at 60 Hz, and independent component analysis was applied using runica (), plugged in EEGLAB, to remove artifacts. Finally, the extracted 5 min of EEG data of each patient were divided into 10 epochs (30-s duration) per patient. The EEG from the C3 and C4 electrodes were selected for data extraction to reduce the muscle and eyeball movement artifacts.

Spectral power analysis (power spectral density)

The PSD estimated the power of each frequency band directly from the signal itself. The PSD (log) was computed by Welch power spectral estimation for each patient with a sampling rate (200 Hz) and 15-s window size length segments in each 30-s epoch. The average in each PSD frequency including delta (0.5–4 Hz), theta (5–7 Hz), alpha (8–14 Hz), beta (15–29 Hz), and gamma (30–100 Hz) extracted from the C3 and C4 electrodes of 10 epochs were calculated.

Variability analysis (event-related spectral perturbation)

ERSP (log) was used to show dynamic brain changes with the zero point in each epoch set as the baseline. ERSPs were analyzed with fast Fourier transform and Hanning window tapering in each 30-s epoch. The mean baseline log power spectrum was subtracted to produce the baseline-normalized ERSP from each spectral estimate, and then deviations from baseline power were calculated. The detail method was described in supplementary method. The averaged each frequency ERSP including delta (0.5–4 Hz), theta (5–7 Hz), alpha (8–14 Hz), beta (15–29 Hz), and gamma (30–100 Hz) extracted from the C3 and C4 electrodes of 10 epochs were calculated.

Randomness analysis (spectral entropy)

SE based on Shannon entropy in physics, quantifying the regularity/randomness of power spectrum during a given time, was used to establish one of the biomarkers for neurological prognosis after cardiac arrest in the recent study50. In effect, SE reflected the randomness of the power spectrum distribution. The greater SE represents the more uniform power spectral distribution51. The detail method was described in supplementary method. The average of each frequency SE including delta (0.5–4 Hz), theta (5–7 Hz), alpha (8–14 Hz), beta (15–29 Hz), and gamma (30–100 Hz) were extracted from C3 the C4 electrodes of 10 epochs were calculated.

Statistical analysis

Continuous variables are presented as median with interquartile range (IQR) due to the non-normal distribution using the Kolmogorov–Smirnov test. In addition, categorical variables are expressed as absolute numbers and percentages. The patients were categorized into two groups based on their CPC scores at 1 month: good neurologic (CPC 1 and 2) and poor neurologic (CPC 3–5)52 neurologic outcome groups were performed using the Mann–Whitney U-test and chi-square test for continuous and categorical variables, respectively.

The linear mixed model analysis for PSD, ESRP, and SE values for all and each frequency band was performed to adjust the random effect of clustering from the epochs of the same patients at 10 time-points and fixed effect of ages of each patient. The age could have an influence on EEG rhythmic activities including delta, theta, alpha, beta, and gamma52 and we adjusted the ages as fixed effect in linear mixed model analysis. Each variable was compared between the good and poor neurologic outcome groups, and receiver operating characteristic curves with 95% confidence intervals for good neurologic outcomes were analyzed to determine the cutoff values to predict neurologic prognosis. Sensitivity and specificity for good neurological outcomes at 1 months were calculated. All statistical analyses were performed using IBM SPSS for Windows, version 21.0 (IBM Corp., Armonk, NY, USA).

Data availability

The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.

References

  1. Atwood, C., Eisenberg, M. S., Herlitz, J. & Rea, T. D. Incidence of EMS-treated out-of-hospital cardiac arrest in Europe. Resuscitation 67, 75–80 (2005).

    PubMed  Article  Google Scholar 

  2. Mozaffarian, D. et al. Heart disease and stroke statistics–2015 update: A report from the American Heart Association. Circulation 131, e29-322 (2015).

    PubMed  Article  Google Scholar 

  3. Dragancea, I., Rundgren, M., Englund, E., Friberg, H. & Cronberg, T. The influence of induced hypothermia and delayed prognostication on the mode of death after cardiac arrest. Resuscitation 84, 337–342 (2013).

    PubMed  Article  Google Scholar 

  4. Lemiale, V. et al. Intensive care unit mortality after cardiac arrest: The relative contribution of shock and brain injury in a large cohort. Intensive Care Med 39, 1972–1980 (2013).

    PubMed  Article  Google Scholar 

  5. Ben-Hamouda, N., Taccone, F. S., Rossetti, A. O. & Oddo, M. Contemporary approach to neurologic prognostication of coma after cardiac arrest. Chest 146, 1375–1386 (2014).

    PubMed  Article  Google Scholar 

  6. Sandroni, C. et al. Prognostication in comatose survivors of cardiac arrest: an advisory statement from the European Resuscitation Council and the European Society of Intensive Care Medicine. Resuscitation 85, 1779–1789 (2014).

    PubMed  Article  Google Scholar 

  7. Nolan, J. P. et al. Outcome following admission to UK intensive care units after cardiac arrest: A secondary analysis of the ICNARC Case Mix Programme Database. Anaesthesia 62, 1207–1216 (2007).

    CAS  PubMed  Article  Google Scholar 

  8. Friberg, H. et al. Survey on current practices for neurological prognostication after cardiac arrest. Resuscitation 90, 158–162 (2015).

    PubMed  Article  Google Scholar 

  9. Hirsch, L. J. et al. The ACNS subcommittee on research terminology for continuous EEG monitoring: Proposed standardized terminology for rhythmic and periodic EEG patterns encountered in critically ill patients. J Clin. Neurophysiol. 22, 128–135 (2005).

    PubMed  Article  Google Scholar 

  10. Tsuchida, T. N. et al. American clinical neurophysiology society standardized EEG terminology and categorization for the description of continuous EEG monitoring in neonates: Report of the American Clinical Neurophysiology Society critical care monitoring committee. J. Clin. Neurophysiol. 30, 161–173 (2013).

    PubMed  Article  Google Scholar 

  11. Gaspard, N. et al. Interrater agreement for Critical Care EEG Terminology. Epilepsia 55, 1366–1373 (2014).

    PubMed  PubMed Central  Article  Google Scholar 

  12. Beuchat, I., Solari, D., Novy, J., Oddo, M. & Rossetti, A. O. Standardized EEG interpretation in patients after cardiac arrest: Correlation with other prognostic predictors. Resuscitation 126, 143–146 (2018).

    PubMed  Article  Google Scholar 

  13. Abend, N. S. et al. Interrater agreement of EEG interpretation after pediatric cardiac arrest using standardized critical care EEG terminology. J. Clin. Neurophysiol. 34, 534–541 (2017).

    PubMed  PubMed Central  Article  Google Scholar 

  14. Sethi, N. K., Westhall, E., Rossetti, A. O. & Cronberg, T. Standardized EEG interpretation accurately predicts prognosis after cardiac arrest. Neurology 87, 1631 (2016).

    PubMed  Google Scholar 

  15. Abend, N. S. et al. Interobserver reproducibility of electroencephalogram interpretation in critically ill children. J. Clin. Neurophysiol. 28, 15–19 (2011).

    PubMed  PubMed Central  Article  Google Scholar 

  16. Grant, A. C. et al. EEG interpretation reliability and interpreter confidence: A large single-center study. Epilepsy Behav. 32, 102–107 (2014).

    PubMed  PubMed Central  Article  Google Scholar 

  17. Young, G. B., McLachlan, R. S., Kreeft, J. H. & Demelo, J. D. An electroencephalographic classification for coma. Can. J. Neurol. Sci. 24, 320–325 (1997).

    CAS  PubMed  Article  Google Scholar 

  18. Freeman, W. D. Continuous EEG in therapeutic hypothermia after cardiac arrest: Prognostic and clinical value. Neurology 81, 855 (2013).

    PubMed  Article  Google Scholar 

  19. Westhall, E. et al. Interrater variability of EEG interpretation in comatose cardiac arrest patients. Clin. Neurophysiol. 126, 2397–2404 (2015).

    PubMed  Article  Google Scholar 

  20. Kim, Y. J., Kim, M. J., Koo, Y. S. & Kim, W. Y. Background frequency patterns in standard electroencephalography as an early prognostic tool in out-of-hospital cardiac arrest survivors treated with targeted temperature management. J. Clin. Med. 9, 66 (2020).

    Google Scholar 

  21. Westhall, E. et al. Standardized EEG interpretation accurately predicts prognosis after cardiac arrest. Neurology 86, 1482–1490 (2016).

    PubMed  PubMed Central  Article  Google Scholar 

  22. Pfurtscheller, G. & Lopes da Silva, F. H. Event-related EEG/MEG synchronization and desynchronization: Basic principles. Clin. Neurophysiol. 110, 1842–1857 (1999).

  23. Roach, B. J. & Mathalon, D. H. Event-related EEG time-frequency analysis: An overview of measures and an analysis of early gamma band phase locking in schizophrenia. Schizophr. Bull. 34, 907–926 (2008).

    PubMed  PubMed Central  Article  Google Scholar 

  24. Delorme, A. & Makeig, S. EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J. Neurosci. Methods 134, 9–21 (2004).

    PubMed  Article  Google Scholar 

  25. Makeig, S., Debener, S., Onton, J. & Delorme, A. Mining event-related brain dynamics. Trends Cogn. Sci. 8, 204–210 (2004).

    PubMed  Article  Google Scholar 

  26. Tafuro, A., Ambrosini, E., Puccioni, O. & Vallesi, A. Brain oscillations in cognitive control: A cross-sectional study with a spatial stroop task. Neuropsychologia 133, 107190 (2019).

    PubMed  Article  Google Scholar 

  27. Chikara, R. K. & Ko, L. W. Global neural activities changes under human inhibitory control using translational scenario. Brain Sci. 10, 66 (2020).

    Article  Google Scholar 

  28. Sowndhararajan, K., Kim, M., Deepa, P., Park, S. J. & Kim, S. Application of the P300 Event-Related Potential in the Diagnosis of Epilepsy Disorder: A Review. Sci Pharm 86 (2018).

  29. Kim, M. J., Yum, M. S., Yeh, H. R. & Ko, T. S. Fast oscillation dynamics during hypsarrhythmia as a localization biomarker. J. Neurophysiol. 119, 679–687 (2018).

    PubMed  Article  Google Scholar 

  30. Uhlhaas, P. J. et al. Neural synchrony in cortical networks: History, concept and current status. Front. Integr. Neurosci. 3, 17 (2009).

    PubMed  PubMed Central  Article  Google Scholar 

  31. Carhart-Harris, R. L. The entropic brain—Revisited. Neuropharmacology 142, 167–178 (2018).

    CAS  PubMed  Article  Google Scholar 

  32. Carhart-Harris, R. L. et al. The entropic brain: A theory of conscious states informed by neuroimaging research with psychedelic drugs. Front. Hum. Neurosci. 8, 20 (2014).

    PubMed  PubMed Central  Article  Google Scholar 

  33. Park, J. H. et al. Effect of depth of anesthesia on the phase lag entropy in patients undergoing general anesthesia by propofol: A STROBE-compliant study. Medicine 99, e21303 (2020).

    CAS  PubMed  PubMed Central  Article  Google Scholar 

  34. Shin, H. W. et al. Monitoring of anesthetic depth and EEG band power using phase lag entropy during propofol anesthesia. BMC Anesthesiol. 20, 49 (2020).

    CAS  PubMed  PubMed Central  Article  Google Scholar 

  35. Gao, X., Yan, X., Gao, P., Gao, X. & Zhang, S. Automatic detection of epileptic seizure based on approximate entropy, recurrence quanti fi cation analysis and convolutional neural networks. Artif. Intell. Med. 102, 101711 (2020).

    PubMed  Article  Google Scholar 

  36. Li, P. et al. Detection of epileptic seizure based on entropy analysis of short-term EEG. PLoS ONE 13, e0193691 (2018).

    PubMed  PubMed Central  Article  Google Scholar 

  37. Backman, S. et al. Highly malignant routine EEG predicts poor prognosis after cardiac arrest in the Target Temperature Management trial. Resuscitation 131, 24–28 (2018).

    CAS  PubMed  Article  Google Scholar 

  38. Halgren, M. et al. The generation and propagation of the human alpha rhythm. Proc. Natl. Acad. Sci. USA 116, 23772–23782 (2019).

    CAS  PubMed  PubMed Central  Article  Google Scholar 

  39. Mierau, A., Klimesch, W. & Lefebvre, J. State-dependent alpha peak frequency shifts: Experimental evidence, potential mechanisms and functional implications. Neuroscience 360, 146–154 (2017).

    CAS  PubMed  Article  Google Scholar 

  40. Li, X., Yang, X. & Sun, Z. Alpha rhythm slowing in a modified thalamo-cortico-thalamic model related with Alzheimer’s disease. PLoS ONE 15, e0229950 (2020).

    CAS  PubMed  PubMed Central  Article  Google Scholar 

  41. Kustermann, T. et al. Electroencephalography-based power spectra allow coma outcome prediction within 24 h of cardiac arrest. Resuscitation 142, 162–167 (2019).

    PubMed  Article  Google Scholar 

  42. Forgacs, P. B. et al. Dynamic regimes of neocortical activity linked to corticothalamic integrity correlate with outcomes in acute anoxic brain injury after cardiac arrest. Ann. Clin. Transl. Neurol. 4, 119–129 (2017).

    PubMed  PubMed Central  Article  Google Scholar 

  43. Moseby-Knappe, M. & Cronberg, T. Can serum markers of brain injury predict neurological outcome after out-of-hospital cardiac arrest? Author’s reply. Intensive Care Med. 48, 248 (2022).

    PubMed  Article  Google Scholar 

  44. Moseby-Knappe, M. et al. Serum markers of brain injury can predict good neurological outcome after out-of-hospital cardiac arrest. Intensive Care Med. 47, 984–994 (2021).

    CAS  PubMed  PubMed Central  Article  Google Scholar 

  45. Geocadin, R. G. et al. Standards for studies of neurological prognostication in comatose survivors of cardiac arrest: A scientific statement from the American Heart Association. Circulation 140, e517–e542 (2019).

    PubMed  Article  Google Scholar 

  46. Kim, Y. J. et al. The role of post-resuscitation electrocardiogram in patients with ST-segment changes in the immediate post-cardiac arrest period. JACC Cardiovasc. Interv. 10, 451–459 (2017).

    PubMed  Article  Google Scholar 

  47. Peberdy, M. A. et al. Part 9: Post-cardiac arrest care: 2010 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 122, S768-786 (2010).

    PubMed  Article  Google Scholar 

  48. Callaway, C. W. et al. Part 8: Post-cardiac arrest care: 2015 American Heart Association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 132, S465-482 (2015).

    PubMed  PubMed Central  Google Scholar 

  49. Kim, Y. J. et al. Long-term neurological outcomes in patients after out-of-hospital cardiac arrest. Resuscitation 101, 1–5 (2016).

    PubMed  Article  Google Scholar 

  50. Tjepkema-Cloostermans, M. C., van Meulen, F. B., Meinsma, G. & van Putten, M. J. A Cerebral Recovery Index (CRI) for early prognosis in patients after cardiac arrest. Crit. Care 17, R252 (2013).

    PubMed  PubMed Central  Article  Google Scholar 

  51. Kapucu, F. E. et al. Spectral entropy based neuronal network synchronization analysis based on microelectrode array measurements. Front. Comput. Neurosci. 10, 112 (2016).

    PubMed  PubMed Central  Article  Google Scholar 

  52. Al Zoubi, O. et al. Predicting age from brain EEG signals—A machine learning approach. Front. Aging Neurosci. 10, 184 (2018).

    PubMed  PubMed Central  Article  Google Scholar 

Download references

Acknowledgements

We thank all participants and their family members for taking part in this study.

Funding

This study was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI19C0481, HC20C0164). In addition, this study was supported by the Basic Science Research Program, through the National Research Foundation of Korea (NRF-2021R1A2C2014304) funded by the Ministry of Science and ICT.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the conception and design of the study; M.-J.K., and Y.-J.K. contributed to the acquisition and analysis of data; M.-J.K., and Y.-J.K. contributed to drafting the text or preparing the figures; all authors critically revised the manuscript for important intellectual content.

Corresponding authors

Correspondence to Mi-Sun Yum or Won Young Kim.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Kim, MJ., Kim, YJ., Yum, MS. et al. Alpha-power in electroencephalography as good outcome predictor for out-of-hospital cardiac arrest survivors. Sci Rep 12, 10907 (2022). https://doi.org/10.1038/s41598-022-15144-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1038/s41598-022-15144-3

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing