Abstract
Carbon nanotubes (CNTs) are cylindrical nanostructures and have unique properties, including flexibility, electrical conductivity, and biocompatibility. We focused on CNTs fabricated with the carbon nanotube yarns (cYarn) as a possible substrate promoting peripheral nerve regeneration with these properties. We bridged a 15 mm rat sciatic nerve defect with five different densities of cYarn. Eight weeks after the surgery, the regenerated axons crossing the CNTs, electromyographical findings, and muscle weight ratio of the lower leg showed recovery of the nerve function by interfacing with cYarn. Furthermore, the sciatic nerve functional index (SFI) at 16 weeks showed improvement in gait function. A 2% CNT density tended to be the most effective for nerve regeneration as measured by both histological axonal regeneration and motor function. We confirmed that CNT yarn promotes peripheral nerve regeneration by using it as a scaffold for repairing nerve defects. Our results support the future clinical application of CNTs for bridging nerve defects as an off-the-shelf material.
Similar content being viewed by others
Introduction
An injured peripheral nerve can regenerate spontaneously or via a microsurgical suture. However, in long-term defects or severe injury, the regeneration capacity of a nerve is limited1. Until recently, an interposition autologous nerve graft has been considered the gold standard for nerve regeneration and has produced the best results for peripheral nerve injury with advanced crushing or defects since the first evidence of autologous nerve grafting in animal studies in 19672,3. However, the use of this technique is not without problems, including limited supply, associated donor-site morbidity, and size mismatches with the injured nerve4. Several artificial nerve conduits have been tested in clinical applications to overcome these limitations of autologous nerve grafting. However, clinical results are limited, feature low success rates, and are typically only used for less than 3 cm nerve gaps involving small-diameter, non-critical sensory nerves5,6.
Therefore, at present, sufficient results cannot be obtained for the treatment of nerve gaps in long or highly functionally critical areas, thus indicating the importance of developing a nerve guide with a stronger therapeutic effect.
This study focused on carbon nanotubes (CNTs) as possible devices to promote peripheral nerve regeneration. In recent years, nanotechnology breakthroughs have advanced the development of new materials, including CNTs. These devices are cylindrical nanostructures, 0.4 to 40 nm in diameter, consisting of interwoven graphene sheets7. Due to the unique properties of CNTs, such as strength, flexibility, conductivity, ease of manufacture, and high biocompatibility8, this material has been of interest in recent years in biomedical and tissue engineering applications9.
In terms of nerve regeneration, several studies have shown that CNTs can support sustainable neuronal survival and promote neuronal outgrowth10,11,12,13,14. For hippocampal neurons cultured on a CNT patterned substrate, CNTs were able to direct neurite outgrowth11. Aminated CNTs and nerve growth factor (NGF) increase the number of neurons with neurite outgrowth in rat PC12h cell and dorsal root ganglion (DRG) neurons in culture media15.
Furthermore, CNTs are ideal for interaction with electrically active tissues, such as neuronal tissues. Neurons that grow on a conductive nanotube meshwork are involved in electrical interactions between CNTs and neurons, which may stimulate neuronal circuits16. According to one review article, network hybrids of neurons and nanotubes may predict or manipulate the interactions between nanomaterials and neurons, leading to the design of smart biomaterials for the engineering of electrically propagating tissues17.
However, in vivo studies on the impact of CNTs in neuro-regeneration are limited, with only one previous study having been conducted. In this study, nerve conduits filled with fibers incorporating aminated CNTs were chemically tethered onto the surface of phosphate glass microfibers (PGF) and implanted in rat sciatic nerve defects18. One reason for the small number of existing in vivo studies is related to the loss of intrinsic properties of individual CNTs that occurs in macroscopic forms of CNTs. Various CNT forms have been demonstrated to overcome this matter, including fibers19,20 yarns21,22. Therefore, we aimed to evaluate the efficacy of CNTs in peripheral nerve regeneration in vivo using the processed CNT yarns as the intraluminal fibers of artificial nerve conduits.
We investigated whether regeneration of peripheral nerves was promoted by transplanting CNT yarn into the nerve defects as a scaffold to explore the possibility of using CNT yarn as a novel artificial nerve material.
Methods
Methods of this study were reviewed and approved by the ethical committee of Hiroshima University. And all experiments were performed in accordance with relevant guidelines and regulations. This study was also carried out in compliance with the ARRIVE guidelines.
Production of the implant
The CNT yarn used in this study was cYarn (LINTEC of AMERICA INC., Nano-Science & Technology Center, Richardson, TX, USA) manufactured through dry drawing and spinning23,24,25,26. As the CNT source, vertically aligned multiwall CNT (MWCNT) forests produced by chemical vapor deposition using acetylene as carbon source and iron as catalyst were used. The typical diameter and length of MWCNT were approximately 10 nm and 300 μm, respectively. Yarns were approximately 15 μm in diameter. For in-vivo tests, CNT yarns were inserted in silicon tubes with a lumen of 15 mm (Fig. 1).
Experimental animals and surgical procedures
Thirty-five female Sprague Dawley rats (8 weeks old and weight: 200–220 g) were used in this investigation. Rats were housed in groups of three animals under standard conditions. For anesthesia, Rompun (20 mg/ml, BAYER HEALTH CARE, Leverkusen, Germany) and Ketalar (50 mg/ml, DAIICHI-SANKYO, Tokyo, Japan) were injected intraperitoneally for each animal. The rat sciatic nerve defect model was induced as previously described27,28. A skin incision was made along the lateral femur, expose the sciatic nerve by dissection of the gluteus and biceps femoris muscles. The sciatic nerve was transected at the middle of the thigh with microscissors. For CNTs transplantation, 10 mm of the sciatic nerve was removed. Just after the nerve injury, 1 mm of both ends of the transected sciatic nerve were inserted into 17 mm silicon tubes filled with 15 mm CNT yarn fibers to bridge the nerve defect. In other words, a 15 mm nerve defect was made. Previous studies have demonstrated that the rat 15 mm sciatic nerve defect model does not spontaneously regenerate nerves27,28. Therefore, in this study, we used a 15 mm sciatic nerve defect model as a negative control, in which a silicon hollow tube was transplanted into the defect. Before implantation, silicon tubes and CNT yarns were washed in NaCl after autoclave sterilization. The proximal and distal nerve stump and tubes were connected by three sutures using 8–0 monofilament nylon thread.
Experimental design and groups
In order to analyze the performance of different densities of CNT fibers in vivo, we created five experimental groups (C0: control group, silicon hollow tube; CN2: CNT yarn filling at a low density of 2% [200 bundles] in the silicon tube; CN5: moderate density of 5% [500 bundles]; CN10: high density of 10% [1000 bundles]; CN35: high density of 35% [3500 bundles]).
Two different observation periods were chosen after which the animals were finally examined and sacrificed prior to the explanation of the implants and regenerated tissue: as short term periods eight weeks (C0, CN2,CN5,CN10,CN35, n = 7 animals in each group), as long term period 16 weeks (C0 n = 6, CN2 n = 7, respectively). The motor recovery was evaluated by calculation of sciatic nerve functional index (SFI) every four weeks and electromyography before sacrifice animals. The examiner was blinded to the implants for sciatic nerve reconstruction applied to each animal. All rats were euthanized with 100% carbon dioxide inhalation after an overdose of Rompun and Ketalar by intraperitoneal injection at the conclusion of the electrophysiological studies.
The sciatic nerves along with the silicon tubes and CNT fibers were harvested 8 weeks and 16 weeks after the surgery. The silicon tubes were removed, and immediately afterward the contents inside the silicon tube with proximal and distal nerve segments were embedded in OCT Compound (TISSUE-TEK, SAKURA FINETEK, Tokyo, Japan). In the 8-week evaluation, the nerve was sectioned longitudinally at 8 µm thickness and in the 16-week evaluation, proximal and distal nerve segments were sectioned transversely at 8 µm thickness. Sectioning was performed in accordance with a method described previously29. The sectioning surface was covered with an adhesive film (CRYOFILM TYPE IIC9, SECTION-LAB, Hiroshima, Japan) and frozen sections were made with a microtome (CRYOSTAT HM520, THERMO FISHER SCIENTIFI K.K., Tokyo, Japan). The resulting sections were stained with hematoxylin and eosin (H&E) and immunohistochemistry analysis using a BZ-9000 microscope (KEYENCE CORP., Osaka, Japan).
Electrophysiological study
Electrophysiological examination was performed according to the method of our facility previously described28. Briefly, the sciatic nerves proximal to the silicone tubes were exposed, and needle electrodes were placed in the gastrocnemius muscle. The nerves were stimulated with a constant current of 2.0 mA (0.2 ms square-wave pulses) using bipolar electrodes. The stimuli were applied to the sciatic nerve proximal to the silicone tube at the experimental side and to the sciatic nerve at the same level as the contralateral side. The compound muscle action potentials (CMAPs) were recorded after stimulation using the Viking Quest system (NICOLET BIOMEDICAL, Madison, WI, USA). The onset latency and peak to peak amplitude of the CMAPs from the experimental side were compared with those recorded from the contralateral side.
Muscle weight ratio
After the animals were sacrificed, the gastrocnemius muscle and tibialis anterior muscle were excised from bilateral hindlimbs and weighed to calculate the ratio of the experimental side compared to the contralateral side.
Immunohistochemistry
Immunohistochemistry was performed, with neurofilament (NF) antibodies marking axons and S100 antibodies identifying Schwann cells. Briefly, the section was fixed in a 4% paraformaldehyde and methanol mixture for 30 s and washed with cold PBS three times for 3 min each time, and then blocked with 10% normal goat serum (LIFE TECHNOLOGY CORP., Carlsbad, CA, USA) at 4 °C for 1 h. Following this, immunostaining was performed with anti-chicken NF protein (ABCAM, Cambridge, UK), diluted 1:200 in PBS and anti-rabbit S100 protein (ABCAM) diluted 1:200 in PBS.
The second day, the sections were washed three times with PBS, then incubated with the secondary antibody Alexa Fluor 488 goat anti-Rb IgG and Alexa Fluor 568 anti-chicken IgG (THERMO FISHER SCIENTIFIC K.K.), diluted in 1:200 in PBS, and coverslipped with DAPI counterstain for 1 h at room temperature. In addition, another immunohistochemistry was performed with CD68 antibodies marking pan-macrophage. Briefly, immunostaining was performed with anti-mouse CD68 protein (ABCAM), diluted 1:100 in PBS. After incubated overnight at 4 °C, then incubated with the secondary antibody Alexa Fluor 350 anti-mouse IgG (THERMO FISHER SCIENTIFIC K.K.), diluted in 1:200 in PBS for 1 h, and cover slipped with DRAQ5 (ABCAM) counterstain for 5 min at room temperature.
The photomicrographs of these sections were taken using a fluorescence microscope (KEYENCE, Osaka, Japan) which connect to a digital camera and computer.
Image analysis
In the longitudinal sections of the 8-week evaluation, the immunoreactivity (IR) of neurofilament, number of S100 positive cells was measured at four areas (P, proximal nerve end; P5, 5 mm from the proximal stump; D5, 5 mm from the distal stump; and D, distal nerve end) in three randomly selected sections. In the cross-sections of the 16-week evaluation, the numbers of neurofilament, the numbers of S100 positive cells and the IR of S100 was measured at the proximal and distal nerve end. The immunoreactivity was calculated using the ratio of the immunoreactivity area at the P5, D5, and D nerve sites to the P site, referring to the previously described methods30,31. For cell count, the numbers of S100 stainable structures with DAPI stained nuclei were counted respectively by manual cell counting. The numbers of CD68 stained multinucleated cells showing activated macrophages were counted at the area of P5 in the longitudinal section to evaluate foreign body reaction to CNT. The analyzing area of each section was 800 × 600 μm. And the magnification of the image was 400x. The ImageJ software (NATIONAL INSTITUTE OF HEALTH [NIH], Bethesda, MD, USA) were used for the analysis.
Statistical analysis
Data are presented as the average ± standard error (SE). One-way ANOVA with post-hoc Tukey–Kramer test was used to determine the differences between groups for CMAPs, muscle weight ratio, and immunohistochemical evaluation in 8 weeks evaluation. Student t-test was used to compare the two groups (C0, CN2) in the 16 weeks evaluation. Statistical significance was established at p < 0.05.
Results
Macroscopic findings
8 weeks after the surgery, five rats did not exhibit any continuity in defect bridging, and two rats exhibited extremely poor continuity with scar-like tissue in the control group. In three of the four groups, those filled with a moderate density of CNT yarn (CN2, CN5, and CN10), the CNT yarn gathered to form one cord. On the surface, white tissue and newly formed capillary vessels were observed. However, tissue formation was not observed around the CNTs macroscopically in the CN35 group (Fig. 2).
Electrophysiological evaluation
In 8 weeks, CMAPs were detected in six of seven rats in each of the CN2 and CN5 groups, and three of seven rats in the CN10 group. The mean latency and the mean amplitude were 4.96 ± 0.63 ms and 4.75 ± 1.05 mV in CN2; 4.95 ± 0.75 ms and 3.08 ± 0.27 mV in CN5; and 5.38 ± 1.24 ms and 4.44 ± 1.18 mV in CN10 respectively. However, no CMAPs were obtained in the C0 or CN35 groups. No significant difference in the latencies and amplitudes between CN2, CN5, and CN10 groups were observed. In 16 weeks, CMAPs were detected six of seven rats in the CN2 groups. However, no CMAPs were obtained in the C0 group (Table 1).
Muscle weight ratio
Muscle weight ratio was expressed as % of the contralateral side. The tibialis anterior muscle weight ratio was significantly greater in the CN2 and CN5 groups compared to the C0 group. The ratios of the gastrocnemius in the CN2, CN5, and CN10 groups were also greater than that of the C0 group (Table 2).
Sciatic nerve functional index (SFI)
There was no significant difference in the sciatic nerve functional index (SFI) between any of the groups at 4 or 8 weeks after surgery. However, at 16 weeks, SFI increased significantly in the CN2 group (− 72 ± 8.5) compared to the C0 group (− 110 ± 2.2) (Fig. 3).
Histological and immunohistochemical evaluation for axonal regeneration of excised sciatic nerve
In the 8-week evaluation, the H&E staining showed that the nerve defect was crosslinked with the regenerated tissue in all cases found in the CN2, CN5, and CN10 groups. However, no meaningful tissue regeneration occurred in the C0 or CN35 groups (Fig. 4).
Triple immune fluorescence provided a visualization of nerve regeneration, in which longitudinal sections of the regenerated tissue were stained using S100 and NF. The ratio of NF immunoreactivity at the distal end was higher in the CN2 and CN5 groups than in the C0 group (CN2: 62.61 ± 5.37%; CN5: 67.65 ± 9.63%). However, there was no significant difference between the CN2 and CN5 groups. In the CN10 group, neural tissue was observed along cYarn fibers; however, the ratio of NF immunoreactivity at the distal end was lower than in the CN2 or CN5 groups (CN10: 14.85 ± 7.48%). No neurofilament was observed at the distal nerve end in the C0 group, and no regeneration of nerve defect tissue was seen in the CN35 group. There was no statistically significant difference in the number of S100 positive cells at the proximal and distal nerve ends between the groups. The numbers of cells were significantly increased in areas P5 and D5 (within the nerve defect) in the CN2 and CN5 groups compared to the CN10 group. In the C0 group, only a few cells were observed in two of seven rats, and in the CN35 group, no tissue regeneration was observed (Fig. 5, Table 3).
In the 16-week evaluation, the number of S100 positive cells and neurofilaments at the distal end were significantly higher in the CN2 group than in the C0 group. (Fig. 6, Table 4).
Immunohistochemical evaluation for foreign body reaction
CD68-positive cells in the regenerated tissue 5 mm from the proximal stump were measured in the longitudinal section. CD68-positive cells were found in the CN2 group at 156.9 (SE22.5)/mm2. On the other hand, these cells were hardly found in healthy nerves (n = 4). (Fig. 7).
Discussion
This study demonstrated successful regeneration of peripheral nerves using CNT yarn as a nerve scaffold in vivo by anatomical as well as functional measures for the first time. In contrast, the 15 mm nerve defect did not show spontaneous reconstruction within a hollow silicone tube as described in the previous studies27,28. These results indicate that the nano-scale topographical scaffold alone enabled significant regeneration, with no exogenous neurotrophic proteins nor cell transplantation. The sagittal section of the immunohistochemical analysis indicated that, across the distance of the transected sciatic nerve, axons extended along with the aligned CNT yarns with migrated Schwann cells and reached the distal stump. Electrophysiological and muscle weight analysis also demonstrated that the CNT constructs facilitated motor nerve regeneration and significantly improved the functional deficit after the peripheral nerve injury. Our results indicated that a 2% CNT density tended to be most effective for nerve regeneration as measured by both histological axonal regeneration and motor function. We consider that tissue regrowth did not occur at the 35% CNT density due to the high occupancy of CNT yarns in the silicon tube, which may have impeded the perfusion of tissue fluid. In addition, 16 weeks long term evaluation was performed in the 2% CNT group which was the optimal outcome in the eight weeks evaluation, and an evident functional recovery including SFI was observed as compared with the hollow silicon tube group.
This study confirmed the effect of CNTs on peripheral nerve regeneration in vivo and clarified the optimum density of CNT fiber scaffold.
However, other biological impacts of CNT yarns, including effects on cell migration ability and cell adhesion, were not elucidated. Further investigations of peripheral nerve regeneration mechanisms alongside this material are needed before more efficient regeneration protocols can be achieved.
In nerve conduits of various materials, it is important that a fibrin matrix forms to bridge the proximal and distal nerve stumps. The fibrin matrix contains inflammatory cells and vascular endothelial cells, and its formation is crucial for the migration and proliferation of Schwann cells and axonal growth. The formation of the fibrin matrix is facilitated by the tube structure to a certain extent, as it connects the proximal and distal nerve ends32,33. However, If the distance between the nerve ends is too long, the matrix is not formed and the regeneration process across the nerve defect is interfered34,35.
Recent studies have revealed the mechanism by which two nerve stumps reconnect during nerve repair. First, macrophages secrete VEGF-A, which stimulates the formation of blood vessels oriented in the direction of nerve regeneration. The Schwann cell cord (Büngner band) is then formed using the polarized blood vessels as a migratory scaffold. Finally, axons extend from the proximal stump to the distal stump, guided by the Schwann cell cord36. In support of these known mechanisms, the intraluminal fibers may induce fibrin cable polarized blood vessels and Schwann cell cords and thus help to bridge the proximal and distal nerve stump over long nerve gaps.
A study culturing rat hippocampal neurons on two patterns of CNT yarns (parallel aligned and cross linked) demonstrated that almost all neurites grow along the CNT yarns in the growth direction of the neurites. Even on the cross-linked CNT yarn patterned substrate, a neurite could grow along one CNT yarn and then turn towards another cross-linked yarn. This indicates that CNT yarns possess the main characteristics of a guidance scaffold for neurite outgrowth37.
Another possible reason why nerve tissue was regenerated along the cYarn fiber is thought to be the CNT character itself and the structural features of our nerve conduit model composed of thin and aligned fibers. A previous study cultured DRG on different diameters of fiber scaffolds and found that the direction and extent of neurite extension and Schwann cell migration from DRG explants was influenced significantly by fiber diameter38. Another study indicated that fibers with smaller diameter have better cell adhesion effects39. In addition, Kim et al. demonstrated that aligned, oriented fibers accelerated DRG outgrowth in vitro and nerve regeneration in vivo compared with randomly oriented fibers40. cYarn fiber is a fiber of 15 μm in diameter, composed of 10 nm fibers. As shown in Fig. 1, the cYarn surface exhibits irregularities due to these 10 nm fibers, therefore increased surface fiber area. Scaffolds with a high surface area are advantageous for cell adhesion and proliferation41.
Although we were able to demonstrate the effectiveness of CNT yarns in peripheral nerve regeneration, this study has several limitations. Firstly, we used an artificial nerve model that combines a silicon tube and CNT yarn, which is far from clinical use. In clinical applications, conduits should be made from biodegradable material. However, in previous in vivo studies examining the effects of nerve guides or cell therapy on nerve regeneration, hollow silicone tubes were inserted as nerve guide in a standard model42,43, in order to obtain external stability to provide space for nerve regeneration to occur.
CD68 positive cells that are recognized as macrophages were observed in the regenerated tissue 16 weeks after the CNT yarn implantation. An undeniable foreign body reaction occurred by transplanting the CNT yarn into living animals. The biocompatibility of CNT yarn is desired to be improved by chemical modification or protein bonding in future study. In this study, we demonstrated only the superiority of CNT yarn over the negative control using the silicone hollow tube. The functional results of muscle weight and SFI are inferior to those of healthy nerves even when CNT yarn is scaffolded. For comparison with autografts and decellularized nerve allografts for clinical use, significant superiority would have to be demonstrated. Finally, we succeeded nerve regeneration in a rat 15 mm sciatic nerve defect. However, to prove clinical efficacy for 30 mm or more defects, we need further studies with a long gap in larger animals.
Currently, animal-related research to promote nerve regeneration by stem cell transplantation is underway. However, stem cell transplantation requires cell harvesting and culturing, causing the transplant surgery to be long in duration, with an associated high cost. On the other hand, CNTs have sterilizable and stable material properties, are mass-producible, and can be provided at a low cost. Therefore, CNT artificial nerves may one day be an off-the-shelf product that is unlimited in supply.
Another biological benefit of CNTs is the ease with which a broad range of molecules can be bound to the yarn, due to the extremely high reactivity of the CNT surface44. Chemical modifications can be made to increase the probability of nerve regeneration, including modification of electrical charge11 and binding of growth factors45.
Conclusions
We confirmed that CNT yarn, used as a scaffold for repairing 15 mm nerve defect in rat sciatic nerve, promotes peripheral nerve regeneration in motor function and histology. Our findings point to 2% CNT yarns as the optimal density for peripheral nerve regeneration. Although CNT yarns require further development in terms of therapeutic effect and biocompatibility, the results of this study support the future clinical application of CNTs as an off-the-shelf material for artificial nerve conduits.
References
Chan, K. M., Gordon, T., Zochodne, D. W. & Power, H. A. Improving peripheral nerve regeneration: From molecular mechanisms to potential therapeutic targets. Exp. Neurol. 261, 826–835 (2014).
Dahlin, L. B. & Lundborg, G. Use of tubes in peripheral nerve repair. Neurosurg. Clin. N. Am. 12, 341–352 (2001).
Millesi, H. Nerve transplantation for reconstruction of peripheral nerves injured by the use of the microsurgical technic. Minerva Chir. 22, 950–951 (1967).
Meek, M. F. & Coert, J. H. Clinical use of nerve conduits in peripheral-nerve repair: Review of the literature. J. Reconstr. Microsurg. 18, 97–109 (2002).
Meek, M. F. & Coert, J. H. US food and drug administration/conformit Europe-approved absorbable nerve conduits for clinical repair of peripheral and cranial nerves. Ann. Plast. Surg. 60(4), 466–472 (2008).
Ray, W. Z. & Mackinnon, S. E. Management of nerve gaps: Autograft, allografts, nerve transfers, and end-to-side neurorrhaphy. Exp. Neurol. 223, 77–85 (2008).
Iijima, S. Helical microtubes of graphitic carbon. Nature 354, 56–58 (1991).
Dubin, R. A., Callegari, G., Kohn, J. & Neimark, A. Carbon nanotube fibers are compatible with mammalian cells and neurons. IEEE Trans. Nanobiosci. 7(1), 11–14 (2008).
Saito, N. et al. Safe clinical use of carbon nanotubes as innovative biomaterials. Chem. Rev. 114(11), 6040–6079 (2014).
Mattson, M. P., Haddon, R. C. & Rao, M. Molecular functionalization of carbon nanotubes and use as substrates for neuronal growth. J. Mol. Neurosci. 14(3), 175–182 (2000).
Fabbro, A., Prato, M. & Ballerini, L. Carbon nanotubes in neuroregeneration and repair. Adv. Drug Deliv. Rev. 65(15), 2034–2044 (2013).
Kotov, N. A. et al. Nanomaterials for neural interfaces. Adv. Mater. 21, 3970–4004 (2009).
Lee, J. H., Lee, J. Y., Yang, S. H., Lee, E. J. & Kim, H. W. Carbon nanotube–collagen three-dimensional culture of mesenchymal stem cells promotes expression of neural phenotypes and secretion of neurotrophic factors. Acta. Biomater. 10, 4425–4436 (2014).
Fabbro, A., Bosi, S., Ballerini, L. & Prato, M. Carbon nanotubes: artificial nanomaterials to engineer single neurons and neuronal networks. ACS Chem. Neurosci. 3, 611–618 (2012).
Matsumoto, K., Sato, C., Naka, Y., Whitby, R. & Shimizu, N. Stimulation of neuronal neurite outgrowth using functionalized carbon nanotubes. Nanotechnology 21(11), 115101 (2010).
Mazzatenta, A. et al. Interfacing neurons with carbon nanotubes: electrical signal transfer and synaptic stimulation in cultured brain circuits. J. Neurosci. 27(26), 6931–6936 (2007).
Dvir, T., Timko, B. P., Kohane, D. S. & Langer, R. Nanotechnological strategies for engineering complex tissues. Nat. Nanotechnol. 6(1), 13–22 (2011).
Ahn, H. S. et al. Carbon-nanotube-interfaced glass fiber scaffold for regeneration of transected sciatic nerve. Acta Biomater. 13, 324–334 (2015).
Ericson, L. M. et al. Macroscopic, neat, single-walled carbon nanotube fibers. Science 305, 1447–1450 (2004).
Li, Y., Kinloch, I. A. & Windle, A. H. Direct spinning of carbon nanotube fibers from chemical vapor deposition synthesis. Science 304, 276–278 (2004).
Jiang, K., Li, Q. & Fan, S. Spinning continuous carbon nanotube yarns. Nature 419, 801 (2002).
Zhang, M. et al. Multifunctional carbon nanotube yarns by downsizing an ancient technology. Science 306, 1358–1361 (2004).
Zhang, M., Atkinson, K. R. & Baughman, R. H. Multifunctional carbon nanotube yarns by downsizing an ancient technology. Science 306, 1358 (2004).
Zhang, M. et al. Strong, transparent, multifunctional, carbon nanotube sheets. Science 309, 1215 (2005).
Xavier, L., Lima, M. D. & Ray, H. Baughman Spinnable carbon nanotube forests grown on thin, flexible metallic substrates. Carbon 48, 3621–3627 (2010).
Lima, M. D. et al. Biscrolling nanotube sheets and functional guests into yarns. Science 331, 6013 (2011).
Kijima, Y. et al. Regeneration of peripheral nerve after transplantation of CD133+ cells derived from human peripheral blood. J. Neurosurg. 110(4), 758–767 (2009).
Ohtsubo, S. et al. The therapeutic potential of ex vivo expanded CD133+ cells derived from human peripheral blood for peripheral nerve injuries. J. Neurosurg. 117(4), 787–794 (2012).
Kawamoto T. Use of a new adhesive film for the preparation of multi-purpose fresh-frozen sections from hard tissues, wholeanimals, insects and plants. Arch Histol Cytol. 66(2), 123–143 (2003).
Berg, A. et al. Axonal regeneration after sciatic nerve lesion is delayed but complete in GFAP- and vimentin-deficient mice. PLoS ONE 8(11), e79395 (2013).
Rodríguez-Sánchez, D. N. et al. 3D-printed nerve guidance conduits multi- functionalized with canine multipotent mesenchymal stromal cells promote neuroregeneration after sciatic nerve injury in rats. Stem Cell Res. Ther. 12(1), 303 (2021).
Dahlin, L. B., Zhao, Q. & Bjursten, L. M. Nerve regeneration in silicone tubes: distribution of macrophages and interleukin-1β in the formed fibrin matrix. Restor. Neurol. Neurosci. 8, 199–203 (1995).
Meyer, C. et al. Chitosan-film enhanced chitosan nerve guides for long-distance regeneration of peripheral nerves. Biomaterials 76, 33–51 (2016).
Mackinnon, S. E. & Dellon, A. L. A study of nerve regeneration across synthetic (Maxon) and biologic (collagen) nerve conduits for nerve gaps up to 5 cm in the primate. J. Reconstr. Microsurg. 6, 117–121 (1990).
Zhao, Q., Lundborg, G., Danielsen, N., Bjursten, L. M. & Dahlin, L. B. Nerve regeneration in a ‘pseudo-nerve’ graft created in a silicone tube. Brain Res. 769, 125–134 (1997).
Cattin, A. L. et al. Macrophage-induced blood vessels guide Schwann cell–mediated regeneration of peripheral nerves. Cell 162(5), 1127–1139 (2015).
Fan, L. et al. Directional neurite outgrowth on superaligned carbon nanotube yarn patterned substrate. Nano Lett. 12(7), 3668–3673 (2012).
Wang, H. B., Mullins, M. E., Cregg, J. M., McCarthy, C. W. & Gilbert, R. J. Varying the diameter of aligned electrospun fibers alters neurite outgrowth and Schwann cell migration. Acta Biomater. 6(8), 2970–2978 (2010).
Tian, F. et al. Quantitative analysis of cell adhesion on aligned micro- and nanofibers. J. Biomed. Mater. Res. A. 84(2), 291–299 (2008).
Kim, Y. T., Haftel, V. K., Kumar, S. & Bellamkonda, R. V. The role of aligned polymer fiber-based constructs in the bridging of long peripheral nerve gaps. Biomaterials 29(21), 3117–3127 (2008).
Park, S. J., Lee, B. K., Na, M. H. & Kim, D. S. Melt-spun shaped fibers with enhanced surface effects: Fiber fabrication, characterization and application to woven scaffolds. Acta Biomater. 8, 7719–7726 (2013).
Lundborg, G., Rosen, B., Dahlin, L., Danielsen, N. & Holmberg, J. Tubular versus conventional repair of median and ulnar nerves in the human forearm: Early results from a prospective, randomized, clinical study. J. Hand Surg. 22, 99–106 (1997).
Lundborg, G., Rosén, B., Dahlin, L., Holmberg, J. & Rosén, I. Tubular repair of the median or ulnar nerve in the human forearm: A 5-year follow-up. J. Hand Surg. 29, 100–107 (2004).
Lacerda, L., Bianco, A., Prato, M. & Kostarelos, K. Carbon nanotubes as nanomedicines: From toxicology to pharmacology. Adv. Drug Deliv. Rev. 58(14), 1460–1470 (2006).
Matsumoto, K. et al. Neurite outgrowths of neurons with neurotrophin-coated carbon nanotubes. J. Biosci. Bioeng. 103(3), 216–220 (2007).
Acknowledgements
This work has been supported by funds from JSPS KAKENHI (Grant Number JP 19K18467), Tuchiya Memorial Medical Foundation, and Takeda Science Foundation to Akira Kodama.
Author information
Authors and Affiliations
Contributions
A.Ko., as the principal investigator, take primary responsibility for the paper. A.Ko., M.I., and A.Ku. conducted the animal experiment. A.Ko. wrote the main manuscript and prepared figures and tables. A.Ku. examined electromyography, SFI, and immunohistochemistry and prepared part of the figures. T.U., M.D.L., and T.K. supported writing the manuscript and conducted cYarn. N.A. directed the research and helped to write the manuscript. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
Akira Kodama, Atsushi Kunisaki, Masakazu Ishikawa, and Nobuo Adachi don't have any conflicts of interest to declare. Takahiro Ueda, Marcio DE. Lima, and Takeshi Kondo are employed by Lintec of America Inc., where cYarn is producted.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kunisaki, A., Kodama, A., Ishikawa, M. et al. Carbon-nanotube yarns induce axonal regeneration in peripheral nerve defect. Sci Rep 11, 19562 (2021). https://doi.org/10.1038/s41598-021-98603-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-98603-7
This article is cited by
-
Electroactive Conduits for Neuroregeneration: A Step Ahead
Regenerative Engineering and Translational Medicine (2024)
-
Oxidation-treated carbon nanotube yarns accelerate neurite outgrowth and induce axonal regeneration in peripheral nerve defect
Scientific Reports (2023)
-
Nanomaterial-Based Scaffolds for Tissue Engineering Applications: A Review on Graphene, Carbon Nanotubes and Nanocellulose
Tissue Engineering and Regenerative Medicine (2023)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.