Abstract
The normal physiologic range of QRS complex duration spans between 80 and 125 ms with known differences between females and males which cannot be explained by the anatomical variations of heart sizes. To investigate the reasons for the sex differences as well as for the wide range of normal values, a technology is proposed based on the singular value decomposition and on the separation of different orthogonal components of the QRS complex. This allows classification of the proportions of different components representing the 3-dimensional representation of the electrocardiographic signal as well as classification of components that go beyond the 3-dimensional representation and that correspond to the degree of intricate convolutions of the depolarisation sequence. The technology was applied to 382,019 individual 10-s ECG samples recorded in 639 healthy subjects (311 females and 328 males) aged 33.8 ± 9.4 years. The analyses showed that QRS duration was mainly influenced by the proportions of the first two orthogonal components of the QRS complex. The first component demonstrated statistically significantly larger proportion of the total QRS power (expressed by the absolute area of the complex in all independent ECG leads) in females than in males (64.2 ± 11.6% vs 59.7 ± 11.9%, p < 0.00001—measured at resting heart rate of 60 beats per minute) while the second component demonstrated larger proportion of the QRS power in males compared to females (33.1 ± 11.9% vs 29.6 ± 11.4%, p < 0.001). The analysis also showed that the components attributable to localised depolarisation sequence abnormalities were significantly larger in males compared to females (2.85 ± 1.08% vs 2.42 ± 0.87%, p < 0.00001). In addition to the demonstration of the technology, the study concludes that the detailed convolution of the depolarisation waveform is individual, and that smoother and less intricate depolarisation propagation is the mechanism likely responsible for shorter QRS duration in females.
Similar content being viewed by others
Introduction
As well known, the physiologically normal adult QRS complex is 80–125 ms wide1,2. It has also been long understood3 that in addition to the heart size and to the ventricular myocardial mass4, the duration of the QRS complex is influenced by the myocyte geometry and layer orientation5, Purkinje fibre tree structure6, and depolarising ion currents7. It is also known that compared to males, females have shorter QRS complex8,9, and that QRS duration disparities exist between races9,10.
The electrophysiologic reasons for the sex and race differences are poorly understood but they cannot be explained by the differences in heart sizes and myocardial volume alone. In proportional terms, adult heart sizes are less variable compared to the QRS duration11 and while heart size reasonably correlates with body size12, the QRS duration does not9. This all potentially makes the broad range of the normal QRS complex durations somewhat unexpected.
The usual understanding of cardiac electrophysiology considers depolarisation sequence as a rather simple ion exchange reaction that propagates along myocardial fibre bands with practically uncontrolled cell to cell excitation transmission across gap junctions. The contribution of the differences in myocyte geometric composition and of the details in Purkinje fibre distribution must thus be rather substantial to explain the appreciable spread of myocardial depolarization duration. Considering these histology factors, the inter-subject differences in the QRS width have to be largely caused by heterogeneity in the propagation of the depolarization sequence including the anisotropic differences between longitudinal and cross-fibre excitation transmission combined with gap junction discontinuities13,14. At the same time, while showing substantial inter-subject differences, QRS complex duration is reasonably stable within each healthy subject, especially when considering repeated measurements at corresponding underlying heart rates9,15. Thus, the anisotropy of excitation propagation is likely to show similar intra-subject stability combined with appreciable inter-subject variability.
To allow clinical assessment of the myocardial depolarisation anisotropy and to permit investigation of its implication among clinically defined populations, a non-invasive method for the assessment of the spatial distribution of myocardial excitation waveforms is needed, preferably based on standard 12-lead electrocardiograms (ECG). Having this need in mind, we have tested the application of singular value decomposition (SVD)16 to the 12-lead QRS complex electrocardiograms. SVD was previously successfully used in a broad spectrum of electrocardiographic studies including, among others, ECG compression17,18, noise removal19, interval measurement20, and ECG component complexity analyses21,22,23. For the purposes of the present study, we have extended SVD algorithms as well as the interpretation of their results applied to the QRS signal complexity analysis. In addition to testing the application of the technology, we aimed at investigating whether the SVD signal analysis would help explaining the differences in QRS complex duration among healthy subjects and whether, similar to the differences in the QRS duration, it would show differences in QRS composition between the sexes. We have researched this using data that have previously been collected in a battery of clinical pharmacology studies.
Methods
Investigated population and electrocardiographic recordings
A collection of Holter recordings previously analysed for a different purpose was used24. Altogether 639 healthy subjects participated at six different clinical pharmacology studies. All subjects were screened before enrolment and all had a normal resting ECG and normal clinical investigation as mandated in clinical pharmacology research25. Clinical conduct of the studies including the procedures of electrocardiogram acquisition adhered strictly to the relevant guidelines and regulations25,26. All these studies were ethically approved by the institutional ethics bodies (Focus in Neuss; Parexel in Baltimore, Bloemfontein, and Glendale; PPD in Austin; and Spaulding in Milwaukee). All subjects gave informed written consent to the participation. All the source studies were conducted in accordance with the Helsinki declaration.
As previously described24, each of the studies included repeated 12-lead day-time Holter recordings in each participant. The recordings were made during multiple baseline days. During these baseline days, study protocols included repeated provocative manoeuvres with the aim of capturing wide heart rates ranges in each participant. The postural provocative manoeuvres included time-points during which the study subjects were, per protocol, in undisturbed supine, unsupported sitting, and unsupported standing positions. In addition to these, other study per-protocol time-points required the subjects to maintain strict supine positions. The Holter recordings used Mason-Likar electrode positions. Clinical conduct of the baseline days did not differ between individual units. The investigation described in this text utilized the baseline Holter recordings when the subjects were off any medication, did not smoke, and refrained from consuming caffeinated drinks. Further details of the clinical pharmacology studies are therefore irrelevant.
Electrocardiographic measurements
Using previously developed technology combining computerized signal processing with visual checks and manual corrections of the measurements24,27,28, multiple 10-s segments were extracted from each of the Holter recordings aiming at the inclusion of segments with different underlying heart rates. That is, in addition to the extractions at pre-specified study time-points described in the previous section, instantaneous heart rate was measured throughout the complete day-time Holters and additional segments were extracted to cover the range of captured heart rates uniformly. These additional extractions were made during times when the study subjects were not restricted by study protocols although the standard clinical pharmacology research requirements were observed20. Apart from the postural provocative manoeuvres, the source studies did not include any physical or mental challenges. During the day-time Holter recordings, the subjects were allowed neither to sleep nor to leave the confined area of the clinical unit.
For each extracted segment, 2-min history of preceding RR interval was obtained and within these 2-min intervals, heart rate was measured in non-overlapping 30-s sections. Extracted segments were used in this study only if they were preceded by reasonably stable heart rates which were defined as the range between minimum to maximum heart rate measured in the 30-s sections not exceeding 5 beats per minute (bpm).
Each extracted 10-s ECG segment was filtered to reduce noise pollution and to eliminate baseline wander27,28. Subsequently, a representative median beat was constructed, as previously used in other ECG studies28,29. Specifically, in the waveforms of the original recording sampled at 1000 Hz, QRS complexes were identified, superimposed by obtaining autocorrelation maxima across all independent leads, and sample by sample medians of all superimposed P-QRS-T morphologies were used to form the representative beat (our unpublished experience suggests that by eliminating outlier values, the sample-by-sample medians reduce the noise of the representative beat compared to sample-by-sample averages). In this representative beat, all 12 leads were superimposed on the same isoelectric axis and QRS onset and offset points were identified using previously developed algorithms27,28. The quality control of the identification of these points included visual verification and manual correction of computerized measurements by at least two independently working cardiologists with subsequent independent reconciliation in case of measurement disagreement. Pattern matching algorithms30 were also applied to ensure that comparable morphologies of QRS onset and offset were measured systematically.
In each measured ECG segment, the QRS width was defined as the time distance between the QRS onset and offset. The underlying heart rate was defined as the heart rate calculated from the averaged duration of the RR intervals in the preceding 2-min (which also included the 10 s of the measured ECG segment itself).
Singular value decomposition
The SVD principles of ECG signal were published in detail many times before16,20,22. In brief, the 12-lead ECG contains only 8 algebraically independent leads I, II, V1, V2, …, V6 since the unipolar limb leads are only simple algebraic combinations of leads I and II. Hence, the ECG signal may be considered to constitute a matrix \({\mathbb{M}}^{8,{n}}\) of voltage values which has 8 rows \({\mathbb{m}}_{i}\) corresponding to individual leads, and \({n}\) columns, each corresponding to one time-instant. That is, each row \({\mathbb{m}}_{i}\) is a function of time and the values \({\mathbb{m}}_{i}\left(t\right)\), where \(0\le t<{n}\), create the image of the \(i\)-th lead of the original ECG recording. The decomposition is based on an algorithm that creates a diagonal matrix \({{\varvec{\Sigma}}}^{8,{n}}\) and matrices \({\mathbb{U}}^{\mathrm{8,8}}\) and \({\mathbb{V}}^{{n},{n}}\) such that \({\varvec{\Sigma}}={\mathbb{U}}^{T}{\mathbb{M}}{\mathbb{V}}\), which means \({\mathbb{M}}={\mathbb{U}}{\mathbb{W}}\), where \({\mathbb{W}}^{8,{n}}={{\varvec{\Sigma}}{\mathbb{V}}}^{T}.\Sigma\) is a diagonal matrix with non-zero values only in the left-most diagonal. These elements of \({\varvec{\Sigma}}\) (all > 0) are the eigenvalues \({\left\{{\sigma }_{i}\right\}}_{i=1}^{8}\) of the decomposition while the columns of matrices \({\mathbb{U}}\) and \({\mathbb{V}}\) are the left and right singular vectors. The rows of matrix \({\mathbb{W}}\) are the algebraically orthogonal components \({\left\{{\lambda }_{i}\right\}}_{i=1}^{8}\) of the decomposition.
Orthogonal ECG signal reconstruction
In previous electrocardiographic SVD applications, the orthogonal components of matrix \({\mathbb{W}}\) were standardly sorted according to the corresponding values of eigenvalues. For the purposes of the present investigation, we used a different approach.
Original ECG signal in matrix \({\mathbb{M}}\) can be reconstructed using only subset of components of orthogonal signal matrix \({\mathbb{W}}\). Specifically, for any subset of the 8 orthogonal components (i.e. any selection of one, two, or more of the components \({\lambda }_{i}\)), a matrix \({\mathbb{X}}^{8,{n}}\) can be created, for which the rows of the subset are the same as the corresponding rows of \({\mathbb{W}}\) while other rows contain zeros. The original matrix \({\mathbb{M}}\) can then be approximated by matrix \({\mathbb{N}}^{8,{n}}={\mathbb{U}}{\mathbb{X}}.\) Each of the 8 rows of matrix \({\mathbb{N}}\) correspond to the approximation of the corresponding ECG lead that originally constituted the matrix \({\mathbb{M}}\).
Various ways of quantifying the difference between \({\mathbb{M}}\) and \({\mathbb{N}}\) ECG signal can be proposed. In this study, we used the perhaps simplest possibility which was to calculate the area between the signals of individual leads of \({\mathbb{M}}\) and \({\mathbb{N}}\). That is for each lead \(l\in \left\{\mathrm{I},\mathrm{II},\mathrm{V}1,\mathrm{V}2,\dots ,\mathrm{V}6\right\}\), we calculated the difference \({\Delta }_{l}\) between original lead \({\mathbb{m}}_{l}\) and its approximation \({\mathbb{n}}_{l}\) as \({\Delta }_{l}=\sum_{t=0}^{{n}-1}\left|{\mathbb{m}}_{l}\left(t\right)-{\mathbb{n}}_{l}\left(t\right)\right|\) and quantified the difference \({\varvec{\Delta}}\) between \({\mathbb{M}}\) and \({\mathbb{N}}\) as the average of all \({\Delta }_{l}\) (i.e. the average over different leads).
Obviously, if the selected subset of the 8 orthogonal components was empty (i.e. if no orthogonal components were used), the matrix \({\mathbb{N}}\) contained only zeros and all \({\Delta }_{l}=\sum_{t=0}^{{n}-1}\left|{\mathbb{m}}_{l}\left(t\right)\right|\).
This allowed to order the orthogonal components \({\left\{{\lambda }_{i}\right\}}_{i=1}^{8}\) according to their contribution to the original ECG signal. That is, we firstly selected a single component \({\lambda }_{1st}\) such that if only this component was used in matrix \({\mathbb{X}}\), the corresponding \({\mathbb{N}}\) to \({\mathbb{M}}\) difference \({\varvec{\Delta}}\) was the smallest among all single components \({\lambda }_{i}\). Subsequently, we selected a second component \({\lambda }_{2nd}\) such that if the matrix \({\mathbb{X}}\) was composed of components (\({\lambda }_{1st} \bigoplus\) \({\lambda }_{2nd}\))—i.e. if the matrix \({\mathbb{X}}\) had only two non-zero rows, the corresponding \({\mathbb{N}}\) to \({\mathbb{M}}\) difference \({\varvec{\Delta}}\) was the smallest among all two component combinations (\({\lambda }_{1st} \bigoplus\) \({\lambda }_{i}\)), where \({\lambda }_{i}\ne {\lambda }_{1st}\). The same process was repeated and \({\lambda }_{3rd}\) was selected for minimum approximation difference based on (\({\lambda }_{1st} \bigoplus\) \({\lambda }_{2nd} \bigoplus\) \({\lambda }_{3rd}\)), and so on, up to the selection of the last \({\lambda }_{8th}\) orthogonal component.
This selection of \(\lambda\) components results in a sequence of \({\mathbb{N}}\) to \({\mathbb{M}}\) differences \({\left\{{{\varvec{\Delta}}}_{i}\right\}}_{i=0}^{8}\) where \({{\varvec{\Delta}}}_{i}\) corresponds to the approximation signals \({\mathbb{N}}\) composed of the first \(i\) components selected during the described selection process. Clearly \({{\varvec{\Delta}}}_{0}\ge {{\varvec{\Delta}}}_{1}\ge {{\varvec{\Delta}}}_{2}\ge \dots \ge {{\varvec{\Delta}}}_{8}=0\). The absolute contribution of the \(i\)-th component to the reconstruction of original ECG signal \({\mathbb{M}}\) is equal to \({{\varvec{\Delta}}}_{i-1}-{{\varvec{\Delta}}}_{i}\). Clearly, the value of this absolute contribution depends on the magnitude of the original ECG and cannot be directly used for comparisons of different ECGs. For that purpose, it is appropriate to consider the contribution of the \(i\)-th component in relative terms, i.e. as a value \({\nabla }_{i}={({\varvec{\Delta}}}_{i-1}-{{\varvec{\Delta}}}_{i})/{{\varvec{\Delta}}}_{0}\).
Geometric interpretation
When applying the SVD algorithm to the QRS complex, i.e. having the columns of matrix \({\mathbb{M}}\) spanning sample-by-sample between QRS onset and QRS offset, \({{\varvec{\Delta}}}_{0}\) becomes the absolute area under the QRS waveforms, i.e. the total “power” of the QRS signal (averaged over all 8 independent leads) and is measured in milliseconds*millivolts. The relative contribution of the first component \({\nabla }_{1}\) specifies the proportion of the signal that can be explained by projection of the depolarisation waveform only in one direction along (and backwards) of the main spatial QRS vector. There are only rare ECGs (example in Fig. 1A) in which almost all the QRS signal is explained by the first component, i.e. for which the electrocardiographic projection of the depolarisation waveform is practically only unidirectional. By the SVD principles, the second component corresponds to a projection of the depolarisation waveform that is perpendicular to the vector of the first component. That is, the sum \({\nabla }_{1}+{\nabla }_{2}\) specifies how much of the QRS signal can be explained by depolarization projection onto a 2-dimensional plane (defined by the perpendicular vectors of components \({\lambda }_{1st}\) and \({\lambda }_{2nd}\)). In some ECGs in which the total QRS power is far from explained by the first component, projection onto a single plane explains most of the QRS signal (example in Fig. 1B). In other ECGs, even the sum of \({\nabla }_{1}+{\nabla }_{2}\) is still substantially below 1 and the third component needs to be added, i.e. more faithful reconstruction of the original signal is obtained by considering the electrocardiographic projection of depolarisation in 3-dimensional space (example in Fig. 1C). Nevertheless, once the QRS signal is fractionated differently in different leads, further components algebraically perpendicular to the 3-dimensional space of the first 3 components (well beyond mental spatial imagination) are needed to reconstruct the original signal (example in Fig. 1D).
For these reasons, the decomposition components \({\nabla }_{i}\) allow expressing the “proportion” of the ECG signal that is represented by electrical field changes in one vector direction, by changes along a combination of two perpendicular vectors, three perpendicular vectors, and so on. Similar attempts of quantifying these proportions were previously made based on decomposition eigenvalues \({\left\{{\sigma }_{i}\right\}}_{i=1}^{8}\)21,22,31. To study the differences between these approaches, we applied the analysis to the QRS complex signals of the data analysed in this study and compared the \({\nabla }_{i}\) values with corresponding eigenvalue proportions The comparison was based on their relative differences, i.e. values which allowed to judge the comparisons independent of the dimension \(i\).
Covariates
In each study subject, covariate analysis was performed using data obtained from all ECGs of the given subject. The relative values of individual components as well as the values of their different combinations (i.e. values \({\nabla }_{i}+{\nabla }_{j}+\cdots\)) were related to the RR intervals representative of the underlying heart rate of the corresponding ECG as well as to the duration of the QRS complex in the ECG. For this purpose, both linear and log-linear regression models were employed. As previously observed9, log-linear model fitted the relationship between QRS duration and the RR intervals better than the linear model. The intra-subject fits of the linear and log-linear models between the relative components and RR intervals and QRS duration were similar (i.e. for some of the components, linear model provided somewhat lower regression residua while for others, the fit by the log-linear model was tighter). For consistency, we have therefore used the log-linear regression models for all the intra-subject dependencies. Although some cases showed noticeable spread of the measured values (example in Figs. 2 and 3) the patterns of the regressions were still clearly detected.
To allow comparisons across subjects, these log-linear regression models were used to project the individual components and their combinations to the heart rate of 60 and 120 bpm, as well as to the QRS duration of 100 ms.
In each subject, Spearman correlation coefficients were also calculated between the values of the relative components and their combinations, and the RR intervals of the underlying heart rate, and the QRS durations.
Statistics and data presentation
Data are presented as means ± standard deviation. Differences between subject groups (mainly between female and male participants) were evaluated using two-sample two-tail t-test assuming different variances of compared samples. Intra-subject comparisons (e.g. comparisons between components projected to heart rates of 60 and 120 bpm) were evaluated using two-tail paired t-test. P-values above 0.05 were considered statistically non-significant (NS). Because of the inter-dependency of evaluated data, no correction for multiplicity of testing was performed and all statistical tests performed are presented.
In each ECG, SVD calculations were made covering the interval between QRS onset and QRS offset. To avoid the possibility of the SVD results being influenced by QRS duration, the calculation was also repeated using a fixed width of the interval covered by matrix \({\mathbb{M}}\) in all ECGs. Specifically, this repeated calculation spanned the interval starting 5 ms before QRS onset and finishing 130 ms later. (The results of the fixed width calculations were only used to confirm the stability of the main analyses that are presented).
The SVD calculations were made using a custom software package developed in C++ (compiler of Microsoft Visual Studio version 15.4.0). Statistical evaluation used IBM SPSS package version 25.
Results
Population and electrocardiographic measurements
The source clinical pharmacology studies investigated 639 subjects (311 females). The ages of sex-defined sub-groups were practically identical (females 33.8 ± 10.1 years; males 33.9 ± 8.7 years, NS). The numbers of analysed ECG samples were also not different between females (609 ± 192) and males (591 ± 200, NS). The complete study evaluated 382,019 ECG samples.
The spread (i.e. the minimum to maximum range) of heart rates of the analysed ECG segments was also similar in females and males (57.8 ± 12.7 vs 56.2 ± 12.7 bpm, NS). Nevertheless, the spread of measured QRS widths was narrower in females (8.7 ± 5.8 ms) compared to that in males (10.2 ± 5.5 ms, p < 0.001). The regression-based extrapolation to the QRS width of 100 ms have thus involved some marginal extrapolations beyond available values, especially for females with markedly short QRS complexes.
Summaries of individual ECG measurements are shown Fig. 4, their numerical values are listed in the Supplementary Table. The observations made with the repeated SVD analyses using the fixed 130 ms intervals were practically the same (not shown here). That is, albeit the numerical values were little different, their proportions and sex comparisons led to the very same conclusions as described further.
Comparison with eigenvalue proportions
In 8.27% of the analysed ECG samples, the order of the decomposition components \({\nabla }_{i}\) was different from the order of SVD eigenvalues \({\sigma }_{i}\) that are standardly used for component ordering16. In 1.40% and 4.10% of the samples, this difference of the order occurred in the first 3 and in the 4th to 6th dimensions, respectively. More important, however, were the numerical differences between components \({\nabla }_{i}\) and the corresponding eigenvalue proportions . These are displayed in Fig. 5 which shows that with higher dimensions, these numerical differences spanned between approximately − 80 to + 40%.
Absolute area under the QRS waveform
Consistent with previous observations9, QRS durations were significantly shorter in females than in males (98.9 ± 5.5 vs 103.5 ± 5.9 ms, p < 0.00001, at 60 bpm, Fig. 6). As also seen in Fig. 6, total QRS area, i.e. the \({{\varvec{\Delta}}}_{0}\) value, was also significantly smaller in females compared to males but this difference was unrelated to the differences in QRS durations (when projected to 100 ms of QRS duration, the \({{\varvec{\Delta}}}_{0}\) areas were 24.21 ± 6.52 and 31.26 ± 9.26 ms*mV in female and males, respectively, p < 0.00001).
Also consistent with previous observations9, we observed QRS widening with increasing heart rate in approximately 30% of the subjects while QRS was shortening with increasing heart rate in others. Similar proportions of subjects showed QRS area to increase and decrease with increasing heart rate but the heart rate influences of QRS duration and of QRS area were practically independent of each other (Fig. 6).
Components of the 3-dimensional space
Within individual subjects, the first relative component (i.e. the \({\nabla }_{1}\) value) was, on average, negatively but moderately correlated with QRS duration (intra-subject Spearman correlation r of − 0.159 ± 0.327 and − 0.146 ± 0.347 in females and males, respectively). It was therefore somewhat surprising that the population correlations between \({\nabla }_{1}\) and QRS duration assessed at specific heart rates were noticeably stronger (− 0.529 and − 0.346 at the rate of 60 bpm, and − 0.528 and − 0.309 at 120 bpm, in females and males, respectively). There was also a noticeable discrepancy between intra-subject relationship of \({\nabla }_{1}\) to QRS duration and to the underlying heart rate. While the intra-subject correlation to QRS was positive in approximately 30% of the subjects, the intra-subject correlation to heart rate was positive in approximately 70% of the subjects. All this is shown in the left panels of Fig. 7 (note the cumulative distributions in panel G of the figure).
The right panels of Fig. 7 show that the relationship of \({\nabla }_{2}\) to heart rate and QRS duration was almost exactly the opposite to that of the \({\nabla }_{1}\). Note that the cumulative distributions shown in panels G and H of the figure are practically mirror images of each other. While the intra-subject correlation with QRS width was only moderately positive (intra-subject r of 0.155 ± 0.330 and 0.149 ± 0.345 in females and males) the population correlation assessed at 60 bpm led to r of 0.474 and 0.290 in females and males, respectively. At 120 bpm, the corresponding r values were 0.443 and 0.234.
Left part of Fig. 8 shows that \({\nabla }_{3}\) values were much less related to QRS duration with averages of intra-subject correlations close to 0 and population correlations at 60 bpm with r of 0.188 and 0.140 in females and males, respectively. When all first three components were combined (i.e. values of \({\nabla }_{1}\)+\({\nabla }_{2}\)+\({\nabla }_{3}\) considered) more than 90% of the QRS absolute area was covered and the population dependency on QRS duration almost disappeared (right part of Fig. 8).
QRS fractionation components
On average, there were no meaningful intra-subject correlations of \({\nabla }_{4}\), \({\nabla }_{5}\), or \({\nabla }_{6}\) to QRS duration (the absolute values of all r averages were below 0.02). This contrasted with the positive population correlations which, at 60 bpm, led to r values of 0.294 and 0.295 in females and males, respectively, for \({\nabla }_{4}\). For \({\nabla }_{5}\), the corresponding r values were 0.329 and 0.292, while for \({\nabla }_{6}\), the r values were 0.388 and 0.305. Similar gradual increase of r from \({\nabla }_{4}\) to \({\nabla }_{6}\) was also seen at heart rate of 120 bpm (Fig. 9).
As expected, the contribution of components \({\nabla }_{4}\) to \({\nabla }_{6}\) was gradually decreasing and in the majority of cases, the component combination \({\nabla }_{4}\)+\({\nabla }_{5}\)+\({\nabla }_{6}\) represented less than 3% of the absolute QRS area. Compared to \({\nabla }_{4}\)+\({\nabla }_{5}\), the combination \({\nabla }_{4}\)+\({\nabla }_{5}\)+\({\nabla }_{6}\) showed only a small albeit noticeable increase while still maintaining relatively strong correlation with QRS duration (Fig. 10). On the contrary, the population heart rate dependency of components \({\nabla }_{4}\), \({\nabla }_{5}\), and \({\nabla }_{6}\) and of their combinations was practically absent (Figs. 9 and 10).
Decomposition residuals
The situation was different with the combination of final components \({\nabla }_{7}\)+\({\nabla }_{8}\)(Fig. 11). On average, this combination showed no intra-subject correlation with QRS complex (r of 0.001 ± 0.151 and − 0.014 ± 0.157 for females and males, respectively). However, in population data, significant correlations with QRS complex were observed. At the rate of 60 bpm, r values of 0.521 and 0.409 were observed for females and males, respectively. At 120 bpm, these r values decreased to 0.332 and 0.237, respectively. Substantial intra-subject effect of heart rate was also noted. Although numerically rather small, the value \({\nabla }_{7}\)+\({\nabla }_{8}\) increased from 0.364 ± 0.087 and 0.402 ± 0.093% in females and males at 60 bpm, to 0.501 ± 0.172 and 0.538 ± 0.189% at 120 bpm (p < 0.00001 and p = 0.012 in females and males, respectively).
Sex comparisons
Since these observations suggest the electrophysiologic basis for shorter QRS duration in females compared to males, Fig. 12 summarises the observed sex differences.
The results were similar for components values projected to 60 bpm and to 120 bpm. Females showed larger \({\nabla }_{1}\) compared to males (e.g. 64.2 ± 11.6 vs 59.7 ± 11.9% at 60 bpm, p < 0.00001) while all \({\nabla }_{2}\) to \({\nabla }_{7}\) are larger in males with different levels of statistical significance. \({\nabla }_{8}\) were also larger in males than in females but we observed statistically significant differences only at 60 bpm while at 120 bpm, the values were still numerically smaller in females (0.241 ± 0.096 vs 0.250 ± 0.099%) but not significantly different.
When eliminating the influence of different QRS durations by using data projected to the same level of 100 ms, the sex comparison was different. The components \({\nabla }_{1}\) to \({\nabla }_{3}\) were practically the same between sexes. \({\nabla }_{4}\) to \({\nabla }_{7}\) were larger in males than in females (the difference did not reach statistical significance for \({\nabla }_{4}\), likely because large spread of projected values in females) while \({\nabla }_{8}\) showed again no difference between sexes.
Discussion
In addition to the setup of the technology, these data analyses offer electrophysiological insights and lead to potentially unexpected observations.
Previous clinical experience with vectorcardiography32,33,34 might lead to expectations that the first two (if not the first three) components \({\nabla }_{1}\) to \({\nabla }_{2}\) (or, in some cases, to \({\nabla }_{3}\)) would contribute similarly to the 3-dimensional composite of the QRS complex. Indeed, the directions of the projections of the first 3 components also create an orthogonal 3-dimensional system which can be represented as an optimal rotation of the XYZ coordinate system so that the maximum QRS power projects into the first direction, the maximum of the reminder into the perpendicular second direction, and so on. Nevertheless, the optimum orientation of coordinates by SVD results in different proportions of the components. It is easy to understand that, in principle, \({\nabla }_{3}\) is a measure of QRS planarity33,35. Since it is known that electrophysiology of normal hearts is characterised by an almost perfect planarity of the spatial QRS loop36,37, the contribution of \({\nabla }_{3}\) only around 3% to 4% of the total QRS absolute area is not surprising. Nevertheless, the practically 2:1 proportion between \({\nabla }_{1}\) to \({\nabla }_{2}\) was somewhat unexpected as was the proportion of subjects in whom \({\nabla }_{1}\) exceeded 80% and \({\nabla }_{2}\) was below 20% (see top panels of Fig. 7). Although similar proportion has previously been described for the eigenvalues of resting ECGs23 we initially assumed that similar to the vectorcardiography images, the contributions of \({\nabla }_{1}\) and \({\nabla }_{2}\) would not be this different since the proportions of this decomposition are not similar those of eigenvalues (see Fig. 5).
The marked differences between the intra-subject and inter-subject relationship of the components to the QRS complex duration suggest that the proportions of the components (perhaps except for \({\nabla }_{7}\) and \({\nabla }_{8}\)) are not determined dynamically by physiologic regulatory processes but are driven by individual anatomic and histologic composites of the ventricular myocardium. Our observations also strongly support the physiologic expectation that even in healthy subjects, narrower QRS complex is a consequence of a more direct and less convoluted path of the depolarisation sequence.
Although the ECG signals were not only filtered but also processed by the construction of median representative beat (which, we believe, also has noise-reduction properties) before applying the SVD analysis, the component \({\nabla }_{8}\), and perhaps also the component \({\nabla }_{7}\), represents mainly the residual noise in the recordings. This is consistent with the marked increase of these components between rates of 60 and 120 bpm which is frequently accompanied by some decrease of signal quality especially if the heart rate increase reflects physical activity.
The observation of the likely relationship between QRS duration and the convolutedness of the depolarisation sequence might also provide insight into the sex difference of QRS complex. The shorter QRS complex duration in females has previously been repeatedly described38. It has also been repeatedly proposed that this sex difference might reflect differences in heart sizes. Nevertheless, this has not been confirmed9. Rather, the sex differences might be driven by the depolarisation sequence initiated by the His-Purkinje system. Our results seem to indicate that compared to males, the propagation of the depolarisation sequence in females is more direct and less curled and twisted. This is not supported only by the proportions between \({\nabla }_{1}\) (larger in females) and \({\nabla }_{2}\) (larger in males) but also by the sex differences in the higher components above the 3-dimensional projections as shown in Fig. 12. Such a lesser complexity of the female depolarisation sequence might also be the basis for the known decreased incidence of ventricular tachyarrhythmias in females39,40,41 (with the exception of channelopathy-based arrhythmias42 that are unrelated to the depolarisation abnormalities). Since the present study evaluated healthy adults with females largely of pre-menopausal ages, we cannot comment on whether the observed sex differences are a consequence of hormonal influence. Electrocardiography studies in children and adolescents43 as well as studies of the influence of menstrual cycle are needed to address these details.
SVD analyses have previously been applied also to body surface maps and multi-lead ECGs44,45. These analyses showed that larger number of independent ECG components can be detected. Nevertheless, since we had only 12-lead ECG available, we were unable to decompose the signals to more than 8 algebraic dimensions corresponding to the number of independent leads. While a system analysing standard 10-s 12-lead ECGs is more practical for further applications of the technology that we have described here, application of the same principles to multi-lead ECG recordings would be of research interest.
Visible fragmentation of the QRS complex has repeatedly been described as an indicator of increased risk of adverse cardiac events46,47,48,49. It has also been observed that fragmented QRS complex is more often present in males compared to females50 and that, in cardiac patients, QRS abnormalities were more predictive in patients with prolonged QRS complex51. Having used data of healthy subjects, we cannot link our methodological results to these studies directly. Nevertheless, the logic of the analysis suggests that the comparison between the orthogonal components \({\nabla }_{1}\) to \({\nabla }_{3}\) and the value of the \({\nabla }_{4}\) to \({\nabla }_{6}\) (or perhaps \({\nabla }_{4}\) to \({\nabla }_{7}\)) components might offer automatic detection of fragmented QRS complex including the distinction of micro-fragmented cases that are not directly apparent during standard visual judgement and diagnosis. Further studies are needed in this respect, but the data presented here might suggest prospectively defined normality limits (e.g. 3.5% for the combination of \({\nabla }_{4}\)+\({\nabla }_{5}\)+\({\nabla }_{6}\) – see Fig. 10). The so-called non-dipolar components (based on eigenvalue proportions) of the T wave have previously been proposed as risk indicators in cardiac patients52. It seems therefore logical to extend this technology also to repolarisation signals.
QRS complex duration, its morphological characteristics, and ECG-based depolarisation abnormalities are also used to optimise and to predict the outcome of cardiac resynchronisation therapy53,54. We are again unable to comment on the possible use of the described technology for these purposes but, based on the electrophysiologic understanding of the analysis, it appears feasible to suggest that studies of this kind might be worth conducting.
Intentionally, we analysed only ECG segments preceded by stable heart rate. This allowed avoiding potential problems with heart rate hysteresis and led to inter-subject differences in the number of analysed ECG segments. Hysteresis-driven disparity between ECG indices and simultaneously measured heart rate occurs when the adaptation to heart rate changes is delayed. This is a known property of repolarisation-related intervals55,56,57 which has important practical implications58,59. Nevertheless, it is not known whether QRS duration exhibits any delayed heart rate adaptation9. Similarly, based on the analysed data, we cannot address the question of how quickly the decomposition components alter in response to abrupt heart rate changes.
Limitations
Further limitations of the analytical technique also need to be considered. The algebraic process of SVD is based on signal reconstruction analysis and therefore cannot map the depolarisation wave propagation directly. The ECG images of localised depolarisation abnormalities might cancel each other and thus be beyond SVD detection. The presented analysis might therefore underestimate but not overestimate depolarisation abnormalities. As already stated, while the span of heart rates covered by different ECGs in individual subjects was reasonably wide, the span of the QRS durations was limited in some subjects. In such cases, the regression projections to 100 ms of QRS duration might have involved substantial extrapolation beyond available data and might thus have polluted the estimates by some errors. The source clinical studies did not involve echocardiographic examinations and we are thus unable to relate the observations to anatomical heart sizes. The original Holter recordings used Mason-Likar electrode positions. We cannot answer the question of whether this influenced the measured values and whether any derived normality limits would be different if standard ECG leads were used. The spans of the ages of the subjects were not wide enough to investigate age influence. Although the ECG signal quality might be influenced by obesity, we have not related the measurements to body mass index.
Conclusion
Despite these limitations, the presented technology and data analyses suggest that components of QRS complex beyond the 3-dimensional reconstruction can reliably be estimated and that they have an electrophysiologic role in judging the propagation of the depolarisation waveform through the myocardium. It appears that the detailed convolution of the depolarisation waveform is individual, and that smoother and less intricate depolarisation propagation is the mechanism responsible for shorter QRS duration in females.
References
Macfarlane, P. W. & Lawrie, T. D. V. The normal electrocardiogram and vectorcardiogram. In Comprehensive Electrocardiology (eds Macfarlane, P. W. et al.) (Springer, London, 2010).
Rijnbeek, P. R. et al. Normal values of the electrocardiogram for ages 16–90 years. J. Electrocardiol. 47, 914–921 (2014).
Boineau, J. P. & Spach, M. S. The relationship between the electrocardiogram and the electrical activity of the heart. J. Electrocardiol. 1, 117–124 (1968).
Mincholé, A., Zacur, E., Ariga, R., Grau, V. & Rodriguez, B. MRI-based computational torso/biventricular multiscale models to investigate the impact of anatomical variability on the ECG QRS complex. Front. Physiol. 10, 1103. https://doi.org/10.3389/fphys.2019.01103 (2019).
Weiss, D. L., Keller, D. U., Seemann, G. & Dössel, O. The influence of fibre orientation, extracted from different segments of the human left ventricle, on the activation and repolarization sequence: a simulation study. Europace Suppl. 6, 96–104 (2007).
Mehdirad, A. A., Nelson, S. D., Love, C. J., Schaal, S. F. & Tchou, P. J. QRS duration widening: reduced synchronization of endocardial activation or transseptal conduction time?. Pacing Clin. Electrophysiol. 21, 1589–1594 (1998).
Carmeliet, E. Conduction in cardiac tissue. Historical reflections. Physiol Rep. 7, e13860. https://doi.org/10.14814/phy2.13860 (2019).
Macfarlane, P. W., McLaughlin, S. C., Devine, B. & Yang, T. F. Effects of age, sex, and race on ECG interval measurements. J. Electrocardiol. 27(Suppl), 14–19 (1994).
Hnatkova, K., Smetana, P., Toman, O., Schmidt, G. & Malik, M. Sex and race differences in QRS duration. Europace 18, 1842–1849 (2016).
Sia, C. H. et al. A population-wide study of electrocardiographic (ECG) norms and the effect of demographic and anthropometric factors on selected ECG characteristics in young, Southeast Asian males-results from the Singapore armed forces ECG (SAFE) study. Ann. Noninvasive Electrocardiol. 24, e12634. https://doi.org/10.1111/anec.12634 (2019).
Mohammadi, S. et al. Study of the normal heart size in northwest part of Iranian population: a cadaveric study. J. Cardiovasc. Thorac. Res. 8, 119–125 (2016).
Vanhaebost, J., Faouzi, M., Mangin, P. & Michaud, K. New reference tables and user-friendly Internet application for predicted heart weights. Int. J. Legal Med. 128, 615–620 (2014).
Klabunde, R. E. Cardiovascular Physiology Concepts (Lippincott, Philadelphia, 2012).
Veeraraghavan, R., Gourdie, R. G. & Poelzing, S. Mechanisms of cardiac conduction: a history of revisions. Am. J. Physiol. Heart Circ. Physiol. 306, H619–H627 (2014).
Mason, J. W. et al. A fundamental relationship between intraventricular conduction and heart rate. J. Electrocardiol. 49, 362–370 (2016).
Acar, B. & Köymen, H. SVD-based on-line exercise ECG signal orthogonalization. IEEE Trans. Biomed. Eng. 46, 311–321 (1999).
Ahmed, S. M., Al-Zoubi, Q. & Abo-Zahhad, M. A hybrid ECG compression algorithm based on singular value decomposition and discrete wavelet transform. J. Med. Eng. Technol. 31, 54–61 (2007).
Kumar, R., Kumar, A. & Singh, G. K. Hybrid method based on singular value decomposition and embedded zero tree wavelet technique for ECG signal compression. Comput. Methods Programs. Biomed. 129, 135–148 (2016).
Jung, W. H. & Lee, S. G. An R-peak detection method that uses an SVD filter and a search back system. Comput. Methods Programs Biomed. 108, 1121–1132 (2012).
Yana, K., Shichiku, H., Satoh, T., Mizuta, H. & Ono, T. An improved QT interval measurement based on singular value decomposition. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2006, 3990–3993 (2006).
Priori, S. G. et al. Evaluation of the spatial aspects of T-wave complexity in the long-QT syndrome. Circulation 96, 3006–3012 (1997).
Acar, B., Yi, G., Hnatkova, K. & Malik, M. Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology. Med. Biol. Eng. Comput. 37, 574–584 (1999).
Schlegel, T. T. et al. Accuracy of advanced versus strictly conventional 12-lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction. BMC Cardiovasc. Disord. 10, 28. https://doi.org/10.1186/1471-2261-10-28 (2010).
Toman, O. et al. Physiologic heart rate dependency of the PQ interval and its sex differences. Sci. Rep. 10, 2551. https://doi.org/10.1038/s41598-020-59480-8 (2020).
Guideline, I. C. H. Safety pharmacology studies for human pharmaceuticals S7A. Fed. Regist. 66, 36791–36792 (2001).
Guideline, I. C. H. 1E14 Clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. Guidance to industry. Fed. Regist. 70, 61134–61135 (2005).
Malik, M. et al. Thorough QT/QTc study in patients with advanced Parkinson’s disease: cardiac safety of rotigotine. Clin. Pharmacol. Therap. 84, 595–603 (2008).
Malik, M. et al. Proarrhythmic safety of repeat doses of mirabegron in healthy subjects: a randomized, double-blind, placebo-, and active-controlled thorough QT study. Clin. Pharm. Therap. 92, 696–706 (2012).
Perez-Alday, E. A. et al. Importance of the heart vector origin point definition for an ECG analysis: the Atherosclerosis Risk in Communities (ARIC) study. Comput. Biol. Med. 104, 127–138 (2019).
Hnatkova, K. et al. Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement. Pacing Clin. Electrophysiol. 32, 119–130 (2009).
Malik, M. et al. QT dispersion does not represent electrocardiographic interlead heterogeneity of ventricular repolarization. J. Cardiovasc. Electrophysiol. 11, 835–843 (2000).
Sur, S., Han, L. & Tereshchenko, L. G. Comparison of sum absolute QRST integral, and temporal variability in depolarization and repolarization, measured by dynamic vectorcardiography approach, in healthy men and women. PLoS ONE 8, e57175. https://doi.org/10.1371/journal.pone.0057175 (2013).
Ray, D., Hazra, S., Goswami, D. P., Macfarlane, P. W. & Sengupta, A. An evaluation of planarity of the spatial QRS loop by three dimensional vectorcardiography: its emergence and loss. J. Electrocardiol. 50, 652–660 (2017).
Jaros, R., Martinek, R. & Danys, L. Comparison of different electrocardiography with vectorcardiography transformations. Sensors 19, 3072. https://doi.org/10.3390/s19143072 (2019).
Choudhuri, S., Ghosal, T., Goswami, D. P. & Sengupta, A. Planarity of the spatial QRS loop of vectorcardiogram is a crucial diagnostic and prognostic parameter in acute myocardial infarction. Med Hypotheses 130, 109251. https://doi.org/10.1016/j.mehy.2019.109251 (2019).
Hiraoka, M., Kawano, S., Sawanobori, T. & Kokusho, S. QRS planarity studies in the vectorcardiogram. Clinical and experimental studies. Jpn. Heart J. 23, 39–48 (1982).
Arnaud, P., Morlet, D. & Rubel, P. Planarity of the spatial QRS loop Comparative analysis in normals, infarcts, ventricular hypertrophies, and intraventricular conduction defects. J. Electrocardiol. 22, 143–152 (1989).
Linde, C. et al. Sex differences in cardiac arrhythmia: a consensus document of the European Heart Rhythm Association, endorsed by the Heart Rhythm Society and Asia Pacific Heart Rhythm Society. Europace 20, 1565–1565ao (2018).
Ubrich, R. et al. (2017) Sex differences in long-term mortality among acute myocardial infarction patients: Results from the ISAR-RISK and ART studies. PLoS ONE 12, e0186783. https://doi.org/10.1371/journal.pone.0186783 (2017).
Zaman, S., Deshmukh, T., Aslam, A., Martin, C. & Kovoor, P. Sex differences in electrophysiology, ventricular tachyarrhythmia, cardiac arrest and sudden cardiac death following acute myocardial infarction. Heart Lung Circ. 29, 1025–1031 (2020).
Gasparini, M. et al. Sex differences in implantable cardiac defibrillator therapy according to arrhythmia detection times. Heart 106, 520–526 (2020).
Johannesen, L. et al. Quantitative understanding of QTc prolongation and gender as risk factors for Torsade de Pointes. Clin. Pharmacol. Ther. 103, 304–309 (2018).
Andršová, I. et al. Individually rate corrected QTc intervals in children and adolescents. Front Physiol. 10, 994. https://doi.org/10.3389/fphys.2019.00994 (2019).
Uijen, G. J. & van Oosterom, A. On the detection of the number of signals in multi-lead ECGs. Methods Inf. Med. 31, 247–255 (1992).
Uijen, G. J. & van Oosterom, A. The performance of information-theoretic criteria in detecting the number of independent signals in multi-lead ECGs. Methods Inf. Med. 31, 256–262 (1992).
Das, M. K. et al. Fragmented QRS on a 12-lead ECG: A predictor of mortality and cardiac events in patients with coronary artery disease. Heart Rhythm 4, 1385–1392 (2007).
Cheema, A. et al. Fragmented QRS and mortality risk in patients with left ventricular dysfunction. Circ. Arrhythm Electrophysiol. 3, 339–344 (2010).
Pietrasik, G. & Zareba, W. QRS fragmentation: Diagnostic and prognostic significance. Cardiol. J. 19, 114–121 (2012).
Xu, S., Yang, L., Hong, D., Chen, L. & Wang, X. Predictive value of fragmented QRS for ventricular tachyarrhythmias in patients with acute myocardial infarction: a meta-analysis. Eur. J. Clin. Invest. 50, e13182. https://doi.org/10.1111/eci.13182 (2020).
Haukilahti, M. A. E. et al. Gender differences in prevalence and prognostic value of fragmented QRS complex. J. Electrocardiol. 61, 1–9 (2020).
Reichlin, T. et al. Automated electrocardiographic quantification of myocardial scar in patients undergoing primary prevention implantable cardioverter-defibrillator implantation: association with mortality and subsequent appropriate and inappropriate therapies. Heart Rhythm 17, 1664–1671 (2020).
Zabel, M. et al. Analysis of T-wave morphology from the 12-lead electrocardiogram for prediction of long-term prognosis in male US veterans. Circulation 105, 1066–1070 (2002).
van Stipdonk, A. M. W. et al. QRS area is a strong determinant of outcome in cardiac resynchronization therapy. Circ. Arrhythm. Electrophysiol. 11, 006767. https://doi.org/10.1161/circep.118.006767 (2018).
Emerek, K. et al. Vectorcardiographic QRS area is associated with long-term outcome after cardiac resynchronization therapy. Heart Rhythm 16, 213–219 (2019).
Malik, M., Johannesen, L., Hnatkova, K. & Stockbridge, N. Universal correction for QT/RR hysteresis. Drug Saf. 39, 577–588 (2016).
Gravel, H., Jacquemet, V., Dahdah, N. & Curnier, D. Clinical applications of QT/RR hysteresis assessment: a systematic review. Ann. Noninvasive Electrocardiol. 23, e12514. https://doi.org/10.1111/anec.12514 (2018).
Hnatkova, K. et al. Heart rate correction of the J-to-Tpeak interval. Sci. Rep. 9, 15060. https://doi.org/10.1038/s41598-019-51491-4 (2019).
Malik, M. et al. Sample size, power calculations, and their implications for the cost of thorough studies of drug induced QT interval prolongation. Pacing Clin. Electrophysiol. 27, 1659–1669 (2004).
Malik, M. et al. Importance of QT/RR hysteresis correction in studies of drug-induced QTc interval changes. J. Pharmacokinet. Pharmacodyn. 45, 491–503 (2018).
Funding
Supported in part by the British Heart Foundation New Horizons Grant NH/16/2/32499 and by Ministry of Health, Czech Republic, conceptual development of research organization (Grant FNBr/65269705).
Author information
Authors and Affiliations
Contributions
Study design: I.A., K.H., M.M., Software development: K.H., M.M., ECG interpretation: I.A., G.S., K.M.H., M.Š., O.T., P.B., P.S., T.N., ECG measurement: I.A., G.S., K.M.H., M.Š., O.T., P.B., P.S., T.N., Supervision of the measurements: G.S., T.N., O.T., P.S., Quality control of the measurements: I.A., G.S., M.M., T.N., Statistics and figures: K.H., M.M., Initial manuscript draft: I.A., K.H., M.M., T.N., Final manuscript: I.A., G.S., K.H., K.M.H., M.M., M.Š., O.T., P.B., P.S., T.N., Approval of the submission: I.A., G.S., K.H., K.M.H., M.M., M.Š., O.T., P.B., P.S., T.N.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Hnatkova, K., Andršová, I., Toman, O. et al. Spatial distribution of physiologic 12-lead QRS complex. Sci Rep 11, 4289 (2021). https://doi.org/10.1038/s41598-021-83378-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-83378-8
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.