Introduction

Gleason pattern 4 (G4) prostate cancer is genetically distinct from Gleason pattern 3 and correlates with worse cancer control outcomes either on active surveillance or following active treatment1,2. In 2013 Pierorazio et al., retrospectively reviewed 7850 radical prostatectomy specimens to investigate the short-term biochemical outcome using a prognostic based scoring system called the Prostate Grading Group (GG). By separating the Gleason sum 7 group into 3 + 4 and 4 + 3, the authors found that men with 4 + 3 had worse outcome defined as biochemical recurrence-free survival3. These findings were further validated and were subsequently endorsed by the 2014 International Society of Urological Pathology Consensus Conference and the World Health Organization (WHO)4,5,6. Additionally, there is some uncertainty about whether %G4 in 3 + 4 cancers is also relevant to management and outcome7,8,9.

This new classification system calls for improved categorisation of the percentage of G4 (%G4) in Prostate Cancer (PCa) to allow for better risk stratification and inform treatment decisions7,9,10,11,12. The distinction between Gleason 3 + 4 (GG2) and 4 + 3 (GG3) is made when %G4 falls below or above 50%, respectively, as visually estimated by a uropathologist5. Additionally, the maximum amount of cancer in any core (maximum cancer core length, MCCL) has been used as a proxy for tumour volume estimation and can be used to define clinical significance13,14.

Most histological prostate cancer burden studies have been performed in radical prostatectomy specimens or on men who have undergone transrectal systematic biopsies. The Prostate MR Imaging Study (PROMIS) includes men who are biopsy naïve whose prostates were systematically sampled every 5 mm providing a unique opportunity to perform an in-depth pathologist-driven annotation and digital analysis of the pathological slides and compare this to the visually-reported %G4 and MCCL15.

In this study, we aimed to compare %G4 and MCCL within standard practice, estimated by a pathologist, to a calculated burden from digitally annotated slides by the same pathologists on thirty patients from the PROMIS study with GG2 and GG3 PCa.

Results

Comparison between visual and digital MCCL

When comparing visual versus digital MCCL, in 23 of the 30 patients the difference was up to ± 2 mm; taking into account the positive and negative values the median difference was 0.58 mm (range − 4.12 to + 5.52 mm, t-test, p = 0.64) (Fig. 1A,B). Seven patients had measurements that differed by ≥ 2 mm between digital and visual estimation. When viewed as a density plot, there was a tendency to overestimate MCCL in the 3 + 4 group and under-estimate in the 4 + 3 group when using the visual method (Fig. 1C). To understand the degree of agreement between the two measurements, a Bland–Altman test was performed16. There was no systematic difference (bias) between the visual and digital assessment of MCCL, and there was no correlation between increasing MCCL and the level of disagreement between the two measurements (Supplementary figure S.1).

Figure 1
figure 1

Objective measurement of MCCL and shows a discrepancy with visual measurement and pathologist estimation. (A) MCCL difference between visual and digital MCCL shows under-estimation in visual compared to digital MCCL. Bar plot of visual MCCL in yellow and digital MCCL in blue, organised by Gleason score. MCCL is plotted on the y-axis; each patient is plotted on the x-axis. Red dashed lines represent a threshold of 6 mm as the MCCL criterion for significance (PROMIS definition 1). Patients highlighted in red were over or underestimated in the original visual measurement. (B) Waterfall plot representing the difference between visual and digital measurements as digital MCCL-visual MCCL by Gleason score (y-axis), patients plotted on the x-axis. Visual Gleason score is represented in yellow for 3 + 4 and blue for 4 + 3. Bars with a negative value represent measurements where the visual MCCL was shorter than the digital MCCL (underestimation). Bars with a positive value represent cases were the visual MCCL was higher than the digital MCCL. The difference in 80% of cases is ± 2 mm (n = 24), red dashed line at − 2 and 2 mm difference. (C) Density plots representing the MCCL distribution between visual and digital images by Gleason scores. Y-axis represents the Kernel density estimation. The X-axis contains MCCL values. Visual MCCL score is represented in yellow and blue for the digital measurement. 4 + 3.The mean visual MCCL was 9.53 mm (5–15 mm) and the mean digital MCCL was 9.88 mm (5.01–15.74).

Gleason 4

The visual %G4 overestimated %G4 burden when compared to the digital assessment in all cases (Fig. 2A). The 4 + 3 group had a mean difference of + 26.6% (range 9.6–41.9%) compared to + 10.8% (range 1.3–24.9%) for the 3 + 4 group (t-test, p = 1.9 × 10–5). The average %G4 in the patients graded 3 + 4 was 11.2% (range 4.7–17.9%) compared to 30.4% (range 12.9–50.6%) in the 4 + 3 group (t-test, p < 0.0001). When pathologists were asked to assess the overall Gleason score based on the digital images (visual %G4), two patients were downgraded from their original clinical grading of 4 + 3 to 3 + 4 by both pathologists (See yellow bars of patients 23 and 18 in Fig. 2A).

Figure 2
figure 2

Visual Gleason 4 appraisal overestimates burden of disease. (A) Bar plot of the proportion of Gleason 4 estimation average between two uropathologists (yellow) and digital estimation (blue). %G4 is plotted on the y-axis; each patient is plotted on the x-axis. A threshold of 50% g4 for clinical significance is shown as a red dashed line. Patient number on the x-axis is highlighted in bold and underlined if the digital measurement of their %G4 would lead to reclassification based on the digital value. Patient marked with * has ≥ 50% G4 in the digital measurement. (B) Bland–Altman plot representing the difference in measurement in the y-axis as visual %G4 – digital %G4. The x-axis represents the mean %G4 measurement of both techniques as (visual %G4 + digital %G4)/2. The bold black line represents complete agreement at 0. The purple dashed line corresponds to the bias at 18.71; the dotted purple line corresponds to the bias confidence interval (33.87–48.75). Dash and dotted blue lines correspond to the upper and lower limit of agreement and confidence intervals are plotted with dotted blue lines. Upper limit of agreement: 41.31 (33.87–48.75), lower limit of agreement: − 3.87 (− 11.31 to 3.56). Regression line is plotted as a continuous blue line.

Using the established 50% G4 threshold to designate a 4 + 3 cancer, and based on the digital %G4 (blue bars), only one patient (number 19 in Fig. 2A) would be classified as 4 + 3. When dividing the digital %G4 into quartiles, two patients in the original 4 + 3 group had less %G4 than the upper quartile of the 3 + 4 group (18 and 30). In other words, these two patients had less %G4 than the men with the highest %G4 compromise in the original 3 + 4 group. Figure 2B shows the Bland–Altman analysis; showing that there was a bias towards overestimation in the visual estimations as all values are located above the line of complete agreement (Complete agreement would result in a zero value). The disagreement was larger when more than 20% of G4 was present (R 0.79, p < 0.0001).

Examination of the index block (block with the highest Gleason score and MCCL), revealed the same findings as previously seen with all tumour containing cores (Fig. 3A). The visual assessment of digitised images downgraded four patients index block from 4 + 3 to 3 + 4 (patients 18, 30,16, and 23). When examining the digital %G4, only two patients reached the 50% G4 threshold (27 and 19), and so would be the only two patients with 4 + 3 disease based on digital measurement. The Bland–Altman analysis revealed a similar trend to that of the overall %G4 analysis. One measurement had a complete agreement between the digital and visual estimate (Patient 6 in Fig. 3A).One patient had a higher digital estimation compared to the visual estimation (Patient 4 in Fig. 3A). This is represented by the only dot in the negative area of Fig. 3B.The disagreement between measurements increased as the amount of %G4 increased (R 0.6, p < 0.0001).

Figure 3
figure 3

Objective measurement of Gleason 4 burden shows a discrepancy between visual measurement and the digital measurement for the index block. (A) Visual %G4 for the index block 30 patients shown in yellow overlaid with digital %G4 in blue. Patients separated by original Gleason grade grouping; 3 + 4 or 4 + 3, and organized by visual %G4. A threshold of 50% G4 for clinical significance is shown as a red dashed line. Patient number on the x-axis highlighted in bold and underlined if the objective measurement of their %G4 would cause reclassification. (B) Bland–Altman plot representing the difference in measurement in the y-axis as visual %G4 − digital %G4. The x-axis represents the mean %G4 measurement of both techniques as (visual %G4 + digital %G4)/2. The bold black line represents complete agreement at 0. The purple dashed line corresponds to the bias at 14.36; the dotted purple line corresponds to the bias confidence interval (9.78–18.94). Dash and dotted blue lines correspond to the upper and lower limit of agreement and confidence intervals are plotted with dotted blue lines. Upper limit of agreement: 38.40 (30.49–46.32), lower limit of agreement: − 9.67 (− 17.59 to − 1.76). The regression line is plotted as a continuous blue line.

When patients were classified using the clinical significance criteria used in PROMIS in which MCCL and Gleason score were combined to derive definitions 1 (≥ 4 + 3 or ≥ 6 mm) and 2 (≥ 3 + 4 or 4 mm) the digital analysis reclassified four patients’ index block as lower risk13. When all blocks were compared using this system, 20 patients had discrepancy between the visual and digital classification, leading to reclassification to higher or lower risk in six and fourteen patients, respectively (Supplementary Figure S2).

Discussion

We have presented an in-depth analysis of 30 men from the PROMIS trial, to establish the level of agreement between the gold standard visual estimation of MCCL and %G4, compared to digitally annotated images. Limitations to this study include: The presence of cribriform pattern was not recorded separately in this study or included in the final analysis. In addition, the pathologists retrospectively assessed %G4 on annotated images, introducing potential bias in their assessment. Finally, no long term follow up currently exists for the PROMIS study, so we are unable to determine the prognostic significance of our findings.

A threshold of 4 mm and 6 mm has been shown to correlate with 95% of lesions that have a volume higher than 0.2 mL or 0.5 mL, respectively13. Demetrios et al. found that MCCL greater than 10 mm can predict T3 disease and large tumour volumes with a hazard ratio (HR) of 5.7314. Using these thresholds and taking into account the difference in the MCCL measurements, there is a potential impact on the treatment options offered. For instance, patients reclassified as having < 6 mm MCCL could be candidates for active surveillance instead of radical therapy (Patients 6, 18, 19 and 20) (Fig. 1A,B). Interestingly, the visual measurement of men with 3 + 4 disease was more likely to be greater compared to men with 4 + 3 disease (Fig. 1C). Despite these differences, the Bland–Altman analysis showed good concordance between the two measurements; thus, the accuracy of the MCCL is not compromised when a digital tool is used.

In our study, the visual estimation of %G4 differed from the digital one; accurate measurement of the G4 burden has been shown to help risk-stratify patients9,17. In a study by de Souza et al., 20% of Gleason 3 + 4 tumours had more extensive G4 disease than the first quartile of 4 + 3 tumours in radical prostatectomy specimens18. In 2014, Huang et al. found that 45% of men with ≤ 5% of G4 in prostate biopsy had insignificant cancer in radical prostatectomy7. Additionally, several papers have shown that tumours with lower %G4 behave closer to GG1 tumours3,8,9,19,20,21,22.

In this study, we found that visual estimation always overestimated the amount of G4 compared to a digitally calculated %G4. For all of these patients, reclassification of the %G4 would potentially lead to a change in treatment options, and imaging follow up. For example, patient 18 was reclassified after digital assessment and would be downgraded from 4 + 3 of > 6 mm to 3 + 4 of < 6 mm (Fig. 2A). The same was found when we examined the index block only.

Integration of %G4 reporting in biopsies and radical prostatectomy specimens is already recommended6. The findings of our study suggest that a re-assessment of %G4 estimation may be required. Reclassification of G4 could lead to a re-evaluation of previously published biomarker and clinical studies and redefine the reference standard for research. The heterogeneity of studies of the prognostic importance of Gleason 3 + 4 disease as compared with Gleason 4 + 3 disease may be a reflection of uncertainty about how much G4 pattern disease is actually shown in specimens and is particularly relevant to treatments such as radiotherapy or ablation where there is no whole mount radical prostatectomy specimen to analyse.

As we move toward the inclusion of digital pathology in standard clinical practice, it will be essential to investigate the differences between human and digital estimation of key pathological parameters and the potential impact this could have on patient care. This will involve adapting the current visual classification to digitally-derived grading. This study does not aim to highlight human error or criticize visual estimation of the pathologists but to encourage the use of technology to improve our understanding of MCCL and G4 burden in prostate cancer, and to seek novel methods to quantify and study the disease. Whilst this type of analysis would be currently challenging to embed directly into clinical practice due to the time taken to contour each region; work is already ongoing to automate this process23,24,25,26,27,28. Identifying relatively overlooked elements, such as %G4, improves the accuracy of the models used in machine learning29, as such future algorithms can be trained to specifically identify %G4, rather than GG alone.

Further research is also needed to develop and validate new thresholds of the burden of G4 against large cohorts with medium and long-term cancer control outcomes.

Materials and methods

Patients

Two-hundred and twenty-six patients from University College London Hospital took part in the PROMIS trial. Men underwent 5 mm sampling using a transperineal template mapping procedure. Of 113 men with Gleason 7 PCa, 85 had significant disease (PROMIS definition 1: Gleason 4 + 3 or MCCL ≥ 6 mm). 15 patients with Gleason 3 + 4 and 15 patients with 4 + 3 disease were selected from the 85, using a random number generator (Table 1; Fig. 4A). A mean of 14.2 ± 8.05 cores per patient (IQR 9, range 2–34) were taken. 192 H&E slides from these 30 patients were scanned using a NanoZoomer-SQ digital slide scanner (Hamamatsu).

Table 1 Gleason 7 patients in the PROMIS cohort and 30 selected patients for in-depth analysis.
Figure 4
figure 4

Patient selection and methods of digital manual annotation. (A) Euler diagram representing patient selection process for 30 patients for in-depth analysis. (B) NDPview2 image of scanned H&E slide of prostate cores from transperineal biopsies, where nuclei are shown in blue, and other structures in pink. From left to right, MCCL measurement in a straight core of 8.5 mm. Approximate visual pathologist measurement marked with a red line (7.76 mm). Following the axis of the core, three measurements in black of 2.53 mm, 2.11 mm and 4.48 mm for a total of 9.12 mm for the digital measurement. (C) Three prostate cores, areas with cancer were contoured in yellow, areas with Gleason 4 were contoured in black. Close up of contours shown in black box. Non-contoured areas correspond to benign prostatic tissue. (D) Equation used to derive percentage Gleason 4.

Digital scan annotations and data collection

Two experienced UCH uropathologists with 16 years (AF) and 1.5 years’ experience (AH) were involved in this study. The 30 cases included in this study were originally reported by AF as part of the PROMIS trial. The pathologists were blinded to the PROMIS Gleason score; scans were shown randomly and assessed by two experienced uropathologists (AF/AH) using NDP.View 2 software. Each slide was systematically assessed as follows: 1. Each core was numbered from left to right. 2. Length of cancer was measured (Fig. 4B). 3. Areas containing any cancer were contoured in yellow (Fig. 4C). 4. Areas containing G4 were contoured in black (Fig. 4C).

The MCCL was reported prospectively by the pathologists during the trial using the integrated ruler in the microscope; this measurement was assigned as ‘visual’ MCCL. In PROMIS, the MCCL was reported by taking into account intervening benign glands (ISUP) and measuring cancer only. For the purposes of this study, the ISUP measurement was used. The ‘digital’ MCCL was derived as follows: If a core was straight, a single measurement was performed. If there was any curvature, manual sequential measurements were performed along the core axes and combined to give the final measurement.

%G4 was not collected as part of the original trial, pathologists retrospectively visually estimated the %G4 per patient to the closest 10% using the annotated images. This was assigned as ‘visual’ %G4. For digital %G4, the software performs instant area measurements. The resulting area (for each yellow and black contours) was prospectively recorded, and an objective percentage of G4 was calculated as shown in equation 1 (Fig. 4D). This total was assigned as ‘digital’ %G4. A separate analysis of the index block was performed separately. The index block was defined as the block with the highest Gleason score and MCCL in combination with concordance with the index lesion on mpMRI.

Statistical analysis

Patients were divided according to the original Gleason score from the PROMIS trial into 3 + 4 and 4 + 3. The routinely performed ‘visual’ estimation for both measurements was used as the reference standard for all comparisons. When comparing two groups, meeting normal distribution (Shapiro–Wilk test) and same variances (F-test), a student t-test was applied. Whenever data was not normally distributed a Mann–Whitney test was performed. To quantify the agreement between the two methods, the Bland Altman method was performed. The visual method was used as a standard for comparison; bias was defined as the average of the difference between the two methods. Limits of agreement were calculated at 95% CI. All analyses were made using R: A Language and Environment for Statistical Computing30. The Bland–Altman analysis was performed using the blandr package for R31.

Ethical approval

All clinical samples were collected from University College London Hospital NHS Trust patients who had provided informed consent. Ethics committee approval was granted by National Research Ethics Service Committee London (reference 11/LO/0185). Access to biobank samples was obtained [reference (EC/21.16)]. All analyses were performed in accordance with relevant guidelines and regulations.