Abstract
Squeezed states of light have been used extensively to increase the precision of measurements, from the detection of gravitational waves to the search for dark matter. In the optical domain, high levels of vacuum noise squeezing are possible due to the availability of low loss optical components and high-performance squeezers. At microwave frequencies, however, limitations of the squeezing devices and the high insertion loss of microwave components make squeezing vacuum noise an exceptionally difficult task. Here we demonstrate direct measurements of high levels of microwave squeezing. We use an ultra-low loss setup and weakly-nonlinear kinetic inductance parametric amplifiers to squeeze microwave noise 7.8(2) dB below the vacuum level. The amplifiers exhibit a resilience to magnetic fields and permit the demonstration of large squeezing levels inside fields of up to 2 T. Finally, we exploit the high critical temperature of our amplifiers to squeeze a warm thermal environment, achieving vacuum level noise at a temperature of 1.8 K. These results enable experiments that combine squeezing with magnetic fields and permit quantum-limited microwave measurements at elevated temperatures, significantly reducing the complexity and cost of the cryogenic systems required for such experiments.
Similar content being viewed by others
Introduction
The measurement of weak signals is at the heart of many important challenges in modern science and engineering, from quantum computing1, to spectroscopy2, to the search for gravitational waves and dark matter3,4. Ultimately, the ability to measure a weak signal is constrained by noise, which at the quantum limit is dictated by vacuum fluctuations of the electromagnetic field. Vacuum fluctuations are a manifestation of the uncertainty principle, where the two quadrature components of a signal I and Q must obey the relation δI2δQ2 > 1/16, where δI2 (δQ2) is the variance of the signal in the I (Q) quadrature, measured in the unitless dimension of photons. This simple inequality provides a way to circumvent the seemingly fundamental constraint imposed by vacuum fluctuations: the noise along one quadrature can be reduced beneath the quantum limit, so long as the noise is increased in the opposite quadrature. This process is known as squeezing and can be exploited to enhance the signal-to-noise ratio (SNR) of a measurement.
A common approach to produce a squeezed state is to use a degenerate parametric amplifier (DPA) to amplify a vacuum state5,6. A DPA exhibits phase-sensitive gain, such that it amplifies noise along one quadrature and deamplifies (or squeezes) it along the other7,8,9,10. It is essential that the DPA behave as a noiseless (i.e. ideal) amplifier, as any noise added will degrade the squeezed state. Moreover, loss between the DPA and the detection apparatus also diminishes squeezing and must be minimized. These requirements make producing highly squeezed states an exceptionally difficult task.
In the optical domain, the availability of high-performance DPAs, ultra-low loss optical components and the relative ease of noiseless optical homodyne measurements have facilitated the demonstration of vacuum states squeezed by as much as 15 dB11. At microwave frequencies, Josephson junction-based parametric amplifiers represent the state-of-the art in microwave noise squeezers4,12. However, higher order nonlinearities present in Josephson parametric amplifiers (JPAs) constrain the amount of squeezing that can be achieved6,8,13,14,15. In addition, microwave components are lossy in comparison to their optical counterparts and microwave signals at the single photon level require near-noiseless amplification prior to measurement with conventional electronics16. As a result, many works have reported only an inferred measurement of squeezing7,12,17, where degradation of the squeezed state between the DPA and detection system is not accounted for. Due to the additional complexity, there are few reports of direct measurements of microwave noise squeezing, where notably 4.5 dB of squeezing was utilized in an axion haloscope to speed up the search for dark matter9.
Here we use a microwave squeezer made from a thin film of niobium titanium nitride (NbTiN), a material that exhibits a weak nonlinearity due to its kinetic inductance10. Unlike previous Josephson junction-based microwave squeezers, the kinetic inductance parametric amplifier (KIPA) is compatible with high magnetic fields and high temperatures and has negligible higher order nonlinearities10. We combine the KIPA with commercial microwave components and custom engineered device enclosures to minimize microwave losses, allowing us to achieve a direct measurement of − 7.8(2) dB of microwave vacuum noise squeezing. In addition, we show that high levels of squeezing can be maintained with the device operated in an in-plane magnetic field of up to 2 T, which permits its integration in applications such as spin resonance spectroscopy8,18,19 and axion detection4,9. Finally, the high critical temperature ( ~ 13 K) of the superconducting film allows the squeezing of thermal states with the device operated at elevated temperatures, enabling vacuum level noise at a frequency of 6.2 GHz and a temperature of 1.8 K. These results show that quantum-noise-limited measurements can be performed at temperatures accessible using affordable pumped Helium-4 cryostats, a noise level that would otherwise only be attainable with comparatively expensive refrigeration technology.
Results
Squeezing setup
The KIPA devices exploit a weakly nonlinear kinetic inductance, which enables a three-wave mixing (3WM) interaction10 in a half-wavelength coplanar waveguide (CPW) resonator (see Fig. 1a). Each KIPA is operated by applying a DC current IDC and a pump tone \({I}_{p}\sin ({\omega }_{p}t+2{\phi }_{p})\), with phase 2ϕp, at approximately twice the device’s resonance frequency ωp ≈ 2ω0. Here ω0 is the resonance frequency of the fundamental mode, with higher-order modes detuned away from multiples of ω0 by the kinetic inductance nonlinearity and dispersion10,19. The phase ϕp determines along which axes each KIPA squeezes or anti-squeezes. The DC current serves two purposes: it tunes the resonance frequency ω0 of the KIPA20,21, and it strengthens the 3WM interaction, whilst leaving the Kerr strength negligibly low22. As a result, we strongly suppress higher order nonlinearities that have previously limited microwave squeezing experiments utilizing JPAs6,13.
To facilitate direct measurements of microwave squeezing, we employ an experimental setup known as a squeezed state receiver (SSR)9, with special care taken to minimize insertion loss and noise in the setup. In our experiments, the SSR is composed of two KIPAs with only a triple-junction circulator between them (Fig. 1b). To enable this configuration, we modify the KIPA design from those used in previous works10,18 by adding a second port, allowing the pump and signal tones to be routed independently. We also make use of on-chip (superconducting) filters to suppress pump leakage (see Supplementary Note 3.B for further details). The two KIPAs are nominally identical but serve two distinct purposes in our experiments: we label the first SQZ because it is used to produce squeezed states from vacuum; we label the second AMP because it is used to noiselessly amplify the squeezed states. Both devices are installed in a dilution refrigerator with a base temperature of 10 mK.
We measure squeezing with a two-step protocol, displayed in Fig. 1c. In the first step SQZ and AMP are both activated, but are made to amplify along orthogonal quadratures, i.e., SQZ produces a squeezed vacuum state aligned on the I-quadrature, whereas AMP anti-squeezes along I. We then measure the variance on \(I,\delta {I}_{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}^{2}\). In the second step, we deactivate SQZ and make a measurement of the variance on same quadrature \(\delta {I}_{{{{{{{{\rm{A}}}}}}}}}^{2}\). Since the only difference between the two steps is the squeezing of the vacuum state, the vacuum squeezing level can be found from the ratio of the two variances \(S=\delta {I}_{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}^{2}/\delta {I}_{{{{{{{{\rm{A}}}}}}}}}^{2}\).
Operation of the parametric amplifiers
Essential to the measurement protocol is that SQZ and AMP operate at the same frequency. This can be achieved over a 215 MHz span by using DC currents IDC to tune the two devices to a mutual resonance frequency ω0 (Fig. 2a). At ω0/2π = 6.23 GHz we measure the phase-insensitive gain of each KIPA by supplying a pump tone with frequency ωp = 2ω0 and varying the frequency ω of a probe tone. In Fig. 2b we show the measurement for SQZ where a maximum power gain of 41.5 dB was achieved for a pump power of Pp = − 33 dBm, with a gain bandwidth product of 2π × 17 MHz. For phase-sensitive amplification, relevant for squeezing, we amplify coherent states with frequency ω0 while keeping the frequency of the pump tone fixed at ωp = 2ω0. Figure 2c shows that the gain of SQZ varies between 50 dB and − 14 dB as a function of the pump phase of SQZ ϕS. The performance of AMP is found to be nearly identical to SQZ (see Supplementary Note 4.C).
In the absence of a probe signal, the field input to SQZ is a vacuum state. By measuring the phase-dependent noise power PN along the I-quadrature, which is directly proportional to the variance of the noise, we demonstrate the squeezing capability of SQZ, with AMP deactivated. When ϕS ≈ π/2, the noise level (blue curve in Fig. 2d) falls slightly below the reference system noise, which is measured when both SQZ and AMP are deactivated (black dashed line in Fig. 2d). Notably, the amount of squeezing observed is modest (−0.14 dB). This is because the next activated amplifier in the detection chain – a high electron mobility transistor (HEMT) amplifier – adds 6.9 photons of noise to each quadrature (see Supplementary Note 4.J), overwhelming the squeezed noise. Even if the following amplifier were quantum-limited but operated in phase-insensitive mode (where a minimum of 0.25 photons of noise is added to each quadrature23), the maximum amount of squeezing that could be achieved is -3 dB. This emphasizes the need for a second DPA in direct measurements of vacuum squeezing, because it can boost the power of the squeezed state above the noise added by the HEMT without introducing additional noise.
Figure 2e presents a direct measurement of squeezing utilizing both SQZ and AMP, as outlined in the protocol described above. The measured noise is plotted as histograms in the IQ-plane, constructed from time traces of the noise (see Methods). The pump phases of SQZ and AMP are set to ϕS = π/2 and ϕA = 0 so that they maximally squeeze and amplify along I, respectively. When SQZ is deactivated (Fig. 2e, red data points), the vacuum state is amplified by AMP, resulting in an ellipse whose major axis is aligned along I. When SQZ is activated (Fig. 2e, blue data points), the variance along I shrinks by an amount corresponding to the achieved vacuum squeezing level, S.
Optimization of direct squeezing
To determine the maximum achievable squeezing in our system, we require the pump phase of SQZ ϕS and the pump phase of AMP ϕA to be aligned precisely, such that the two devices amplify along orthogonal axes. As expected, we observe high levels of squeezing whenever ϕS ≈ ϕA + π/2 (Fig. 3a). At the optimal setpoint, we observe a maximum squeezing of \(10\log (S)=-7.8(2)\) dB (Fig. 3b, c). We emphasize that this level of squeezing is not an inferred value, but rather a direct measurement of an itinerant squeezed state without correcting for loss or system noise. The maximum squeezing presented in Fig. 3c is achieved at ω0/2π = 6.23 GHz, corresponding to IDC = 0.90 mA for SQZ and IDC = 0.97 mA for AMP. However, through the DC current tunability of the devices (Fig. 2a), we are able to demonstrate squeezing levels beyond − 7 dB over a frequency span exceeding 100 MHz, see Supplementary Fig. S17a.
Squeezing is found to saturate with the gain of both amplifiers (Fig. 3d, e). This can be explained using a model based on input-output theory which captures several distinct mechanisms that limit S (see Supplementary Note 2.B). In the high AMP gain limit, the squeezing level becomes
where \({n}_{{{{{{{{\rm{S}}}}}}}}}^{{{{{{{{\rm{sq}}}}}}}}}\) is the number of noise photons added by SQZ to I when it is squeezing, \({n}_{{{{{{{{\rm{A}}}}}}}}}^{{{{{{{{\rm{anti}}}}}}}}}\) is the number of noise photons added by AMP to I when it is anti-squeezing, GS is the squeezing gain (0 ≤ GS ≤ 1) and η1 is the SQZ to AMP transmission efficiency. Fitting our measurements to the full model (Supplementary Eq. S21) yields a combined factor \({\eta }_{1}(1/4-{n}_{S}^{{{{{{{{\rm{sq}}}}}}}}})/(1/4+{n}_{A}^{{{{{{{{\rm{anti}}}}}}}}})=0.85\). From independent measurements of the amplifier added noise we determine \({n}_{{{{{{{{\rm{S}}}}}}}}}^{{{{{{{{\rm{sq}}}}}}}}}=0.02(2)\) and \({n}_{{{{{{{{\rm{A}}}}}}}}}^{{{{{{{{\rm{anti}}}}}}}}}=0.00(2)\) (see Supplementary Note 4.J), which yields η1 = 0.92(8), equivalent to − 0.34 dB of insertion loss. This finding is in close agreement with our estimates based on the components in our setup, as detailed in the Supplementary Information (Supplementary Note 1.B).
What is not captured by the model is the degradation of S observed when the gain of SQZ exceeds 20 dB, which may be explained by an increased sensitivity of the deamplification gain to small drifts in ϕS as the pump power is increased (see Fig. 2c and Supplementary Fig. S18).
Squeezing in magnetic fields
Several applications requiring strong magnetic fields benefit from the use of squeezed states, including electron spin resonance spectroscopy8,24 and dark matter axion detection4. Previous works have utilized JPAs but have required the amplifiers to be magnetically shielded. In contrast, several recent works have demonstrated magnetic field-resilient resonant amplifiers based on materials with kinetic inductance25,26, though it remains an outstanding goal to realize highly squeezed states in such an environment.
To demonstrate the magnetic field-resilience of our squeezing setup, we modify our experiment so that SQZ is exposed to a magnetic field B∥, while the rest of the components (including AMP and the circulator) are magnetically shielded (Fig. 4a). B∥ is aligned to be in-plane with SQZ, to minimize the creation of magnetic flux vortices, which is expected to introduce additional loss in the resonator27. Figure 4b and c show that the squeezing level remains below − 7 dB up to B∥ = 1.5 T. This level of squeezing is slightly less than was demonstrated in Fig. 3c, which might be explained by a slight shift of the optimal operation point in the modified setup.
The degree of squeezing we achieve is initially found to increase with B∥, which is paired with an increase in Qi (see Supplementary Fig. S12). A similar effect was observed in ref. 28 for NbTiN resonators measured in in-plane magnetic fields. As B∥ is raised beyond 1 T, however, S becomes limited by the internal quality factors of SQZ and AMP, both of which begin to degrade. Interestingly, the maximum field at which we measured squeezing (2 T) is limited by AMP, not SQZ. At larger fields, AMP loses superconductivity as a result of the stray magnetic field, which is a factor of ~ 200 less than B∥, but is not aligned in-plane. This implies that a high degree of squeezing can be achieved at fields greater than 2 T with careful alignment of the magnetic field with both amplifiers.
Squeezing at elevated temperatures
Next, we leverage the high critical temperature of our amplifiers to demonstrate squeezing of the noise produced by a hot thermal bath down to the vacuum level. By heating up not only the input state, but also SQZ and the circulator, we demonstrate that our setup is capable of reducing thermal microwave noise to the quantum limit, at temperatures up to 1.8 K.
We detect the squeezed thermal states with AMP, which is mounted on the mixing chamber of the dilution refrigerator and remains at its base temperature TMC ≈ 10 mK. In contrast, SQZ and the circulator are both thermally anchored to a variable thermal source (VTS) which is heated to a temperature TH (Fig. 4d). Raising TH generates a thermal state containing n photons that is directed to the input of SQZ. The photon number per quadrature is given by n = nth + 1/4, where \({n}_{{{{{{{{\rm{th}}}}}}}}}={[\exp (\hslash \omega /{k}_{B}{T}_{{{{{{{{\rm{H}}}}}}}}})-1]}^{-1}/2\) is the number of thermal photons in each quadrature, with kB the Boltzmann constant and ℏ the reduced Planck constant.
In Fig. 4e, we present measurements performed at four values of TH. At each setpoint, we measure the noise power of the signal with both amplifiers activated (\({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}\)) and when only AMP is activated (\({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\)). The latter is indicated in Fig. 4e as a series of dashed lines, which rise in power with TH because of the increased thermal noise n(TH) as the input state is heated. At each temperature, \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}\) can be reduced below \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\) for pump phases ϕS ≈ π/2. We define this reduction to be the level of thermal squeezing, Sth. In Fig. 4f we show that Sth initially increases with TH, and saturates at \(10\log ({S}_{{{{{{{{\rm{th}}}}}}}}})=-10.2(1)\) dB for TH in the range 1 − 2 K. As TH is increased further, Sth begins to deteriorate, which we attribute to a decline in the internal quality factor Qi of SQZ with TH (see Supplementary Fig. S13).
We note that the maximum level of thermal squeezing achieved here is greater than the vacuum squeezing shown in Fig. 3c. This is because as the temperature increases, the impact of KIPA-added noise on squeezing reduces (see Supplementary Note 2.D), in which case the squeezing is predominantly limited by the insertion loss between SQZ and AMP. This allows us to estimate the transmission efficiency between SQZ and AMP as η1 = 0.927(3) for this experiment, which translates to an insertion loss of − 0.33 dB (see Supplementary Fig. S19). Although the experimental setup depicted in Fig. 4d differs from the one in Fig. 1b in that it includes an additional superconducting coaxial cable between SQZ and AMP, the extracted insertion loss is in close agreement with the earlier found value of − 0.34 dB.
The squeezed thermal states can also be measured relative to the vacuum level (black horizontal line in Fig. 4e). By comparing the measurements of \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}\) taken at temperature TH with the vacuum reference (see Supplementary Fig. S20), we show that S degrades monotonically with TH (Fig. 4g). At TH = 1.8 K, the level of squeezing is \(10\log (S)=0\) dB, indicating that the noise of the thermal state has been squeezed to the vacuum level.
Discussion
There are several avenues available for improving the amount of vacuum squeezing achieved. A significant limitation is the insertion loss of the microwave components that the itinerant squeezed state traverses9. The data in Fig. 4g suggests up to −10 dB of squeezing could be reached with the existing setup if the insertion loss were the only factor degrading squeezing. Whilst already low, the − 0.34 dB of insertion loss could be reduced further by integrating the squeezing devices within the same enclosure as the circulator, circumventing the need for connectors along the squeezed state path, or fully integrating the two KIPAs using on-chip circulators29,30.
A second factor that limits vacuum squeezing is the noise added by the two KIPAs. Given the measured noise performance of SQZ and AMP, squeezing is limited to − 11.0 dB in the absence of insertion loss (Eq. (1)). This indicates that insertion loss and added noise combine almost equally to limit squeezing in our experiment. The KIPA added noise could be reduced further by carefully impedance-matching the pump port and the cavity or by reducing the impedance of the cavity, thereby lowering the required pump power and any associated heating.
Phase instability in the setup can also limit squeezing. Any deviation from the optimal squeezing angle ϕS = π/2 will mix in gain-dependent anti-squeezed noise, with this penalty becoming increasingly severe as the squeezer gain is increased. This is a known source of squeezing degradation in optical setups and techniques that improve phase stability (e.g. phase-locked loops) could also be employed in future microwave squeezing experiments31.
Besides the ease of fabrication, the single NbTiN layer design of these devices give the squeezers a unique resilience to magnetic fields and elevated temperatures, making their use attractive in a variety of applications. For instance, the high levels of microwave squeezing already demonstrated here inside magnetic fields and at high temperatures could find immediate application in electron spin resonance (ESR) spectroscopy8,18, permitting quantum-limited spin detection at temperatures consistent with conventional ESR spectroscopy operating conditions ( ≳ 2 K), but without the need for expensive cryogenic systems. Similarly, the search for dark matter axions4,9 could be sped up by a factor of six compared to the quantum limit, or axion detectors could be simplified (negating the need for extensive magnetic field compensation and shielding) and made more widely available by installing them in low-tech pumped Helium-4 cryostats.
Squeezed vacuum states are also a valuable resource in measurement-based computation schemes using entangled cluster states encoded in the modes of an electromagnetic field32,33. Critically, it has been shown that fault-tolerance with this approach can be attained using vacuum states squeezed by at least 10 dB34, which is within reach of our current setup. Superconducting circuits also offer the ability to deterministically prepare non-Gaussian states of light35, an essential resource in such schemes.
Methods
KIPA Hamiltonian
The Hamiltonian governing the operation of the KIPA is given by
which is defined in a frame rotating at half of the pump frequency ωp/210. Here \(\hat{a}\) (\({\hat{a}}^{{{{\dagger}}} }\)) is the bosonic annihilation (creation) operator, Δ = ω0 − ωp/2 is the frequency detuning, \(\xi=-{e}^{-i2{\phi }_{p}}{\omega }_{0}{I}_{{{{{{{{\rm{DC}}}}}}}}}{I}_{p}/(4{I}_{*}^{2})\) is the 3WM strength, where I* determines the susceptibility to a DC current. K is the self-Kerr interaction responsible for four wave mixing (4WM). The ratio ∣ξ/K∣, which is used to indicate how susceptible a 3WM device is to higher-order nonlinearities13, can be as large as 108 10.
Device fabrication
The devices are fabricated on 15 nm thick films of NbTiN deposited on an intrinsic, high-resistivity silicon chip. The devices are patterned using electron beam lithography followed by a reactive ion etch with an CF4:Ar plasma. The devices both consist of four main components: the first is a band-stop stepped-impedance filter constructed from a series of nine quarter-wavelength (λ/4) CPW segments with alternating high- (Zhi) and low-impedance (Zlo), through which we introduce the DC current IDC and pump Ip. The second component is a half-wavelength (λ/2) resonator, based on an interdigitated capacitor design. The third component is a fifth-order low-pass Chebyshev stepped impedance filter, which is constructed from five alternating Zhi and Zlo segments of varying lengths, through which we introduce the signal. The on-chip low-pass filter is crucial to avoid KIPA pump tone cross-talk. The final component is a shunt inductance to ground, which dictates the coupling quality factor Qc of the resonator. The inductance is chosen so that Qc ≈ 200, thereby ensuring the resonator is strongly over-coupled to the signal port. See Supplementary Note 3.B for further details on the device design and simulations.
Device packaging
The two KIPA devices were mounted to their own enclosures. Both enclosures were constructed from gold-plated oxygen-free copper and act as a rectangular waveguide whose cutoff frequency is greater than the KIPAs, thereby suppressing radiation losses. The two ports of each KIPA were wire bonded to minimally-sized printed circuit boards, to minimize dielectric and ohmic losses. The devices were connected in series via a low-loss triple junction circulator. All measurements were completed with the devices mounted to the mixing chamber of a dilution refrigerator with a base temperature of 10 mK. See Supplementary Note 1 for further details on the device enclosure, mounting, and fridge wiring.
Homodyne reflection measurements
Measurements of the devices are performed in reflection and recorded with a vector network analyzer (VNA), a spectrum analyzer or an oscilloscope.
We use a VNA to measure the resonance frequency and quality factors of the resonators, which we obtain from fits of S11(ω) to a cavity input-output model (see Supplementary Note 4.A). The phase-insensitive gain of both SQZ and AMP are acquired with the same setup.
We acquire the noise ellipses in Fig. 2e by demodulating the output noise with an IQ-mixer and recording the I and Q time traces on an oscilloscope with a sampling rate of 8.33 MSa/s. We apply a digital low-pass filter with a cutoff frequency of 150 kHz (the same cutoff frequency as in the squeezing measurements of Figs. 3, 4) to filter out noise outside of the bandwidth of SQZ and AMP. We then bin the time traces to create a histogram in the IQ-plane.
The noise squeezing measurements are performed with a spectrum analyzer by measuring the noise power PN of one quadrature of the homodyne-demodulated output signal. We measure the demodulated noise on I with a bandwidth resolution of 300 Hz and average over a bandwidth of 120 kHz (30 kHz-150 kHz, see Supplementary Fig. S17b for the bandwidth dependence of squeezing). An empirical definition of squeezing is \(S={P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}/{P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\) where \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}\) and \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\) are the noise powers measured when both SQZ and AMP are activated and when only AMP is activated, respectively.
We find the maximum squeezing level by applying a simple protocol. First, we set ϕA = 0 to maximize \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\). We then turn on SQZ and measure \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}({\phi }_{{{{{{{{\rm{S}}}}}}}}})\) to estimate the ϕS that minimizes S. We take repeated measurements across a small range of ϕS and record S(ϕS) using interleaved measurements of \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{A}}}}}}}}}\) and \({P}_{{{{{{{{\rm{N}}}}}}}}}^{{{{{{{{\rm{S}}}}}}}},{{{{{{{\rm{A}}}}}}}}}\). We account for phase drifts in the microwave pump sources by an alignment procedure displayed in Supplementary Fig. S18.
Measurements in magnetic fields
For the experiments where SQZ is measured in a magnetic field, a 6 T/1 T/1 T vector magnet is installed in the dilution refrigerator. SQZ is placed in the center of the magnet, on the cold finger of the dilution refrigerator and connected to the circulator via a short length of semi-rigid NbTi superconducting cable, with the setup otherwise identical compared to the experiments performed at zero field. AMP and the circulator, situated on the mixing chamber plate, are partially magnetically shielded by a lead enclosure.
Measurements at elevated temperatures
For the experiments where SQZ is used to squeeze thermal states, SQZ and the circulator are thermally anchored to the thermal noise source, while AMP is thermally anchored to the mixing chamber plate and connected to the circulator via a a short length of semi-rigid NbTi superconducting cable.
Data availability
All data needed to evaluate the conclusions in the paper are present in the paper and/or the Supplementary Information. The raw data from this study are openly available in the Zenodo repository https://zenodo.org/uploads/10730079.
Code availability
Measurement scripts, analysis code used to process the raw data and scripts to create all figures are available in the online repository https://zenodo.org/uploads/10730079.
References
Gambetta, J. M., Chow, J. M. & Steffen, M. Building logical qubits in a superconducting quantum computing system. npj Quantum Inf. 3, 2 (2017).
Bienfait, A. et al. Reaching the quantum limit of sensitivity in electron spin resonance. Nat. Nanotechnol. 11, 253–257 (2016).
Aasi, J. et al. Enhanced sensitivity of the ligo gravitational wave detector by using squeezed states of light. Nat. Photonics 7, 613–619 (2013).
Backes, K. M. et al. A quantum enhanced search for dark matter axions. Nature 590, 238–242 (2021).
Yamamoto, T. et al. Flux-driven Josephson parametric amplifier. Appl. Phys. Lett. 93, 042510 (2008).
Malnou, M., Palken, D. A., Vale, L. R., Hilton, G. C. & Lehnert, K. W. Optimal operation of a josephson parametric amplifier for vacuum squeezing. Phys. Rev. Appl. 9, 044023 (2018).
Castellanos-Beltran, M. A., Irwin, K., Hilton, G., Vale, L. & Lehnert, K. Amplification and squeezing of quantum noise with a tunable Josephson metamaterial. Nat. Phys. 4, 929–931 (2008).
Bienfait, A. et al. Magnetic resonance with squeezed microwaves. Phys. Rev. X 7, 041011 (2017).
Malnou, M. et al. Squeezed vacuum used to accelerate the search for a weak classical signal. Phys. Rev. X 9, 021023 (2019).
Parker, D. J. et al. Degenerate parametric amplification via three-wave mixing using kinetic inductance. Phys. Rev. Appl. 17, 034064 (2022).
Vahlbruch, H., Mehmet, M., Danzmann, K. & Schnabel, R. Detection of 15 dB Squeezed States of Light and their Application for the Absolute Calibration of Photoelectric Quantum Efficiency. Phys. Rev. Lett. 117, 110801 (2016).
Qiu, J. Y. et al. Broadband squeezed microwaves and amplification with a josephson travelling-wave parametric amplifier. Nat. Phys. 19, 706–713 (2023).
Boutin, S. et al. Effect of higher-order nonlinearities on amplification and squeezing in josephson parametric amplifiers. Phys. Rev. Appl. 8, 054030 (2017).
Liu, G. et al. Josephson parametric converter saturation and higher order effects. Appl. Phys. Lett. 111, 202603 (2017).
Frattini, N. E., Sivak, V. V., Lingenfelter, A., Shankar, S. & Devoret, M. H. Optimizing the nonlinearity and dissipation of a SNAIL parametric amplifier for dynamic range. Phys. Rev. Appl. 10, 054020 (2018).
Eichler, C., Bozyigit, D. & Wallraff, A. Characterizing quantum microwave radiation and its entanglement with superconducting qubits using linear detectors. Phys. Rev. A 86, 032106 (2012).
Zhong, L. et al. Squeezing with a flux-driven Josephson parametric amplifier. N. J. Phys. 15, 125013 (2013).
Vine, W. et al. In situ amplification of spin echoes within a kinetic inductance parametric amplifier. Sci. Adv. 9, eadg1593 (2023).
Vine, W. et al. Latched detection of zeptojoule spin echoes with a kinetic inductance parametric oscillator. Sci. Adv. 10, eadm7624 (2024).
Annunziata, A. J. et al. Tunable superconducting nanoinductors. Nanotechnology 21, 445202 (2010).
Vissers, M. R. et al. Frequency-tunable superconducting resonators via nonlinear kinetic inductance. Appl. Phys. Lett. 107, 062601 (2015).
Vissers, M. R. et al. Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing. Appl. Phys. Lett. 108, 012601 (2016).
Caves, C. M. Quantum limits on noise in linear amplifiers. Phys. Rev. D. 26, 1817–1839 (1982).
Eichler, C., Sigillito, A. J., Lyon, S. A. & Petta, J. R. Electron spin resonance at the level of 104 spins using low impedance superconducting resonators. Phys. Rev. Lett. 118, 037701 (2017).
Xu, M., Cheng, R., Wu, Y., Liu, G. & Tang, H. X. Magnetic field-resilient quantum-limited parametric amplifier. PRX Quantum 4, 010322 (2023).
Splitthoff, L. J. et al. Gate-tunable kinetic inductance parametric amplifier. Phys. Rev. Appl. 21, 014052 (2024).
Bothner, D. et al. Reducing vortex losses in superconducting microwave resonators with microsphere patterned antidot arrays. Appl. Phys. Lett. 100, 012601 (2012).
Kroll, J. et al. Magnetic-field-resilient superconducting coplanar-waveguide resonators for hybrid circuit quantum electrodynamics experiments. Phys. Rev. Appl. 11, 064053 (2019).
Chapman, B. J. et al. Widely tunable on-chip microwave circulator for superconducting quantum circuits. Phys. Rev. X 7, 041043 (2017).
Navarathna, R. et al. Passive superconducting circulator on a chip. Phys. Rev. Lett. 130, 037001 (2023).
Lough, J. et al. First Demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory. Phys. Rev. Lett. 126, 041102 (2021).
Menicucci, N. C. et al. Universal quantum computation with continuous-variable cluster states. Phys. Rev. Lett. 97, 110501 (2006).
Asavanant, W. et al. Generation of time-domain-multiplexed two-dimensional cluster state. Science 366, 373–376 (2019).
Tzitrin, I. et al. Fault-tolerant quantum computation with static linear optics. PRX Quantum 2, 040353 (2021).
Campagne-Ibarcq, P. et al. Quantum error correction of a qubit encoded in grid states of an oscillator. Nature 584, 368–372 (2020).
Acknowledgements
J.J.P. acknowledges support from an Australian Research Council Discovery Early Career Research Award (DE190101397). J.J.P. and A.M. acknowledge support from the Australian Research Council Discovery Program (DP210103769). A.M. is supported by the Australian Department of Industry, Innovation and Science (Grant No. AUS-MURI000002). A.K. acknowledges support from the Carlsberg Foundation. A.V., W.V. and T.D. acknowledge financial support from Sydney Quantum Academy, Sydney, NSW, Australia. This research has been supported by an Australian Government Research Training Program (RTP) Scholarship. The authors acknowledge support from the NSW Node of the Australian National Fabrication Facility. We thank Robin Cantor and STAR Cryoelectronics for sputtering the NbTiN film, and David Niepce from Low Noise Factory for discussions on circulator losses. Finally, we acknowledge Tony Melov for producing the artist’s impression of the device in Fig. 1a.
Author information
Authors and Affiliations
Contributions
A.V., A.K., and W.V. performed the experiments and analyzed the data. A.K., W.V. and J.J.P. designed the device. W.V. fabricated the devices. T.D. designed the device enclosures and variable thermal source. J.J.P. and A.M. supervised the project. A.V., A.K., W.V., and J.J.P. wrote the manuscript with input from all authors.
Corresponding author
Ethics declarations
Competing interests
J.J.P. is an inventor on a patent related to this work (AU2020347099) filed by the University of New South Wales with a priority date of 09 September 2019. The authors declare that they have no other competing interests.
Peer review
Peer review information
: Nature Communications thanks Baleegh Abdo, Roberto Di Candia and Mingrui Xu for their contribution to the peer review of this work. A peer review file is available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Vaartjes, A., Kringhøj, A., Vine, W. et al. Strong microwave squeezing above 1 Tesla and 1 Kelvin. Nat Commun 15, 4229 (2024). https://doi.org/10.1038/s41467-024-48519-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-024-48519-3
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.