Introduction

Thermal management is a central problem in computer engineering. This is true for classical processors, where the inability to remove heat from transistors resulted in a stalled clock frequency for the last 20 years1, and this is also true for superconducting quantum processors where various temperature-dependent factors limit their coherence. Scaling up quantum processors2 inevitably exacerbates this problem and minimising the impact from all decoherence mechanisms at play is essential for achieving fault-tolerant quantum computing3,4.

Cooling of devices operated in cryogenic vacuum represents a significant challenge because all solid-state cooling pathways—through quasiparticles in the superconducting material and phonons both there and in the substrate—become inefficient. A large body of experimental data indicates physical observables becoming temperature-independent below ~50 mK, well above the dilution refrigerator base temperature of ~10 mK. This is consistently seen in qubit state population5,6,7,8, qubit coherence times9, frequency flicker noise10,11, surface electron spin polarisation12, and qubit flux noise13. Improvement may be achieved by reducing the heat load from various external sources, such as ionising radiation3,14, cosmic particles15,16, and high-frequency photons17,18,19, by careful shielding and filtering. This approach has had a lot of success over the years and is still a subject of intense research and technical development. However, further progress cannot be achieved without taking due care of the circuit’s material environment, for which, unexpectedly, further cooling can lead to increased noise and decoherence.

Although naively one would think that cooling a superconducting circuit to the lowest possible temperature would freeze out any noisy environment, this is only partly true. To suppress decoherence originating from equilibrium quasiparticles17 or residual thermal qubit excitations5,6,7,8 the temperature shall be significantly below relevant energy scales, i.e. T 300 mK for a device operating at 6 GHz. However, well below these temperatures other decoherence mechanisms, in particular that associated with the dielectric environment of the devices, come into play. Dielectrics contain defects, which act as two-level systems (TLS) and counter-intuitively, noise due to TLS increases upon cooling10,20.

Here we present a radically different route to approach these challenges by immersion cooling of a superconducting circuit in liquid 3He. The Fermi liquid 3He has a thermal conductivity that increases with decreasing temperature, and its cooling to below 1 mK is well established21. Thermalisation of liquid 3He to the immersion cell’s metal body is ensured by silver heat exchangers, where the thermal boundary resistance is known to be significantly smaller than the prediction of acoustic mis-match theory. By contrast, liquid 4He is superfluid in this temperature regime and is an excitation vacuum with poor thermal conductivity and relatively high boundary resistance.

We show that 3He provides an efficient heat sink for the circuit environment and dramatically increases the energy relaxation rate of the TLS bath, while otherwise appearing essentially inert to the quantum circuit itself. 3He immersion thus opens up multiple ways in which significant improvement in circuit coherence may be achieved, both by cooling and by suppressing coherence in the noisy environment. Future optimisation of such quantum bath suppression using 3He may lead to significantly reduced noise also at dilution refrigerator base temperatures.

Experimentally, our approach is to use planar superconducting resonators, which have emerged as a convenient platform to interrogate the decohering environment10,12,22,23,24,25,26,27. In particular, the amplitude of the low-frequency 1/f fluctuations in resonator center frequency (1/f frequency noise) is very sensitive to the TLS temperature20. Additionally, the temperature of the surrounding spin bath reveals itself in the electron spin resonance (ESR) spectrum measured via field-dependent losses of the same resonators. When the resonator is immersed in 3He, we observe improved thermalisation of the TLS in the noise measurements and of the spin bath in the ESR measurements, as illustrated in Fig. 1.

Fig. 1: Immersion of a superconducting quantum circuit in liquid 3He.
figure 1

a In vacuum the environment of the quantum circuit is poorly thermalised to the cold plate of the refrigerator. b When immersed in liquid 3He, the cooling of the environment is significantly improved by 3He acting as a heat sink. c A superconducting resonator, used in our measurements, taking the temperature of the decohering environment of quantum circuits. d Experimental setup: The immersion cell containing the sample is thermally anchored to an adiabatic nuclear demagnetisation stage that reaches T = 400 μK. The nuclear stage is mounted to the mixing chamber plate of a dry dilution refrigerator. e Energy relaxation pathway from the TLS bath to the cold plate via 3He and silver sinter. The link between TLS medium and liquid 3He is the bottleneck for further quantum bath suppression.

Results and discussion

Derived from recent advances in ultra-low temperature technology and the cooling of electronic systems to sub-mK temperatures28,29 we construct an immersion cell suitable for a superconducting quantum circuit. Cooling is achieved by placing the circuit, in our case an NbN superconducting resonator30 on a sapphire substrate, inside the immersion cell, as shown in Fig. 1d. The superfluid leak-tight copper cell with RF feed-throughs and extensive RF filtering provides a well-controlled microwave environment. It is thermally anchored to the experimental plate of an adiabatic nuclear demagnetisation refrigeration (ANDR) stage attached via a superconducting heat switch to the lowest temperature plate (10 mK) of a dry dilution refrigerator31. The experimental plate of the ANDR (located in the field-compensated region of the ANDR superconducting magnet) can reach temperatures of ≈400 μK, as measured using SQUID noise thermometry31. The cell can be filled with 3He via a thin capillary. To ensure good thermalisation of the liquid 3He to the cell’s metal enclosure silver sinter heat exchangers are implemented (see Supplementary Note 1 for further details). For ESR spectroscopy experiments a magnetic field (B) up to 0.5 T parallel to the sample surface could be applied. We refer to the section “Methods” for details on our measurement techniques.

Reliable thermometry is an essential prerequisite for the interpretation of ultra-low temperature data. On-chip ESR not only reveals the presence of unwanted surface spins coupling to the resonator through their magnetic moments (a source of flux noise13,32) but also serves as an intrinsic thermometer in the relevant temperature range.

To this end, we show in Fig. 2 that, unlike previous experiments on spins coupled to quantum circuits where the spin polarisation was saturated at about T = 50 mK12, surface spins are cooled to much lower temperatures in the presence of 3He, with no other apparent change in the ESR spectra. The measured ESR spectrum is rather complex, consisting of many different species, and has been discussed in detail previously12,33. Here we focus on the species that are most suitable for intrinsic thermometry at these low temperatures, namely the two peaks labeled 1 and 3 that arise from atomic hydrogen12. The hyperfine interaction in the hydrogen atom results in two electronic spin transitions separated in energy by 1.42 GHz (=68 mK), with a relative intensity that follows the Boltzmann distribution. Thus if spins are cooled to zero temperature the transition involving the higher energy level transition (peak 3) will vanish, the trend clearly seen in Fig. 2 in the presence of 3He. See also Fig. S15 for further ESR results demonstrating cooling by a thin 3He film. Having established improved thermalisation of surface spins we now turn to the TLS bath that couples through charge dipoles to the same circuit.

Fig. 2: Cooling of surface electron spins.
figure 2

Continuous wave electron spin resonance spectra of surface spin intrinsic to a 5.85 GHz resonator, measured with an average number of photons circulating in the resonator of 〈N〉 ≈ 200. \({Q}_{B}^{-1}\) is the change in inverse quality factor (loss) measured in a magnetic field, with zero field losses subtracted. Inset: Normalised intensity of the hyperfine-split atomic hydrogen peaks (labeled 1 and 3) versus nuclear stage noise thermometer temperature. Empty symbols represent measurement in a vacuum and filled symbols in 3He. Error bars are propagated errors from fitting the peak intensities. Solid lines are the expected peak intensities based on the thermal population of ESR levels hyperfine-split by A = 1.42 GHz. The dashed line is an estimate of the minimum sensitivity of our technique, below which we could not detect the third peak. This sets an upper bound on the temperature of the H spins of around 15 mK.

Figure 3a compares the temperature dependence of the 1/f frequency noise of a 6.45 GHz resonator with vacuum or 3He in the sample cell (for more data on different devices, see Supplementary Note 4). Similar to many previous experiments10,11,34,35,36, in vacuum the noise increases on cooling according to a power law T−1.5 followed by saturation to a constant level below ~80 mK due to insufficient thermalisation.

Fig. 3: Cooling the TLS bath by immersion into 3He reduces noise.
figure 3

a The magnitude of the 1/f frequency noise power spectral density Sy(f) of a ν0 = 6.45 GHz superconducting resonator evaluated at f = 0.1 Hz versus nuclear stage temperature for two selected microwave drive powers (average photon number 〈N〉) with the cell full of 3He (filled markers) and empty cell (empty markers). The latter has been scaled by a factor 20 for better visualisation (see Supplementary Note 4 for an unscaled version). Each dataset is a single temperature ramp taking ≈ 6 days. Solid and dashed slopes show Tβ in the low and high-temperature regimes respectively, with β = 0.25 and −1.5, respectively. Horizontal dashed line is a guide for the eye. The shaded region indicates the high-temperature regime where the noise is expected to deviate from the indicated scaling law. For more details on the noise around the 3He superfluid transition temperature (~0.9 mK) (see Supplementary Note 4F). b Photon number dependence of the noise with 3He at selected temperatures taken across shorter timescales (5 h per temperature). Solid lines are fits to the expected dependence of the noise (\(\propto {(1+\langle N\rangle /{N}_{c})}^{-1/2}\)) where the weak fields regime with a leveling-off to a constant noise versus 〈N〉 is evident at high temperatures. Full noise spectra across all timescales can be found in Supplementary Note 4. For a description of error bars, we refer to Supplementary Note 3. Error bars in temperature indicate the whole range of temperature drift during data collection.

When the cell is filled with 3He the situation is very different. The noise changes with fridge temperature all the way down to 1 mK. Above 100 mK the magnitude and temperature dependence of the noise is the same in vacuum and in 3He, but below a certain crossover temperature Tx ~ 80 mK the noise instead starts to decrease with reduced temperature according to a power law T0.25. Remarkably, 3He immersion appears to break the predicted20 trend of increasing noise with cooling (otherwise expected to persist to well below 10 μK, see below). The noise measured at 1 mK is more than three orders of magnitude below this expected T−1.5 trend.

A further striking effect of immersing the circuit in 3He is revealed in the dependence of the internal quality factor Qi of the resonators on the microwave power (photon number, 〈N〉), presented in Fig. 4a for three temperatures. Noticeably, 3He does not affect Qi at the single photon level, meaning that the number of TLS present and their coupling to the resonator remains unchanged. Both for resonators in vacuum and in 3He the microwave excitation power increases Qi—a well-known effect of TLS saturation—but for resonators immersed in 3He the same Qi is achieved with ~1000 times higher power; i.e. we find a dramatic increase in the characteristic TLS saturation power by three orders of magnitude. Figure 4b showing the Qi extracted at a fixed drive power in the saturated regime indicates that there is a weak but steady dependence (and hence cooling) down to < 1 mK. Furthermore, we also here observe a crossover occurring around Tx ~ 80 mK.

Fig. 4: 3He increases TLS relaxation.
figure 4

a Comparison of the TLS-limited internal quality factor Qi for a 6.26 GHz resonator with and without 3He in the cell, for three temperatures. 3He increases the power needed to saturate to a given Qi by a factor ~1000. b The change in internal Q vs. temperature for a fixed drive power of 〈N〉 ~ 104. c Extracted critical photon number Nc times a prefactor c, from fitting the Qi(N) data to \(1/{Q}_{{{{{{\rm{i}}}}}}}\propto {{{{{{{\rm{\ln }}}}}}}}(c{N}_{{{{{{\rm{c}}}}}}}/\langle N\rangle )\). Solid line shows T1.25, the expected scaling of Γ2. Error bars for all panels are 95% confidence bounds from fits to experimental data, and error bars in temperature indicate the whole range of temperature drift during data collection.

A notorious challenge in noise measurements (and more generally in operating quantum circuits requiring long-term stability2,37,38,39) is the inherent instabilities of TLS energies on longer timescales (spectral drift). This is particularly evident in the low power data in Fig. 3a. To circumvent this problem, we measure noise at a somewhat higher photon number which saturates the most strongly coupled fluctuators40. Yet, we stay in a moderately weak fields regime20, as evidenced by the power dependence of the noise shown in Fig. 3b. In the low power data in Fig. 3a the measured noise level varies on top of the general trend by a factor of 2–3 during the course of the measurement, which takes ~6 days; however, the overall trend remains unchanged.

To understand the full body of experimental data we first focus on the region 100–250 mK where the noise is well understood. Here the noise is increasing upon cooling both in a vacuum and in 3He, consistent with previous observations and fully captured by the generalised tunneling model (GTM)20 for interacting TLS defects.

In the GTM both energy loss and 1/f noise arise from the resonator coupling to a large number of coherent (near-)resonant TLS defects. These TLS drain energy from the resonator and dissipate it to substrate phonons, a process that determines Qi, a measure of the average energy loss into the whole TLS bath. They also, through their coherent coupling, mediate frequency fluctuations from the environment: the resonant coherent TLS are subjected to thermally activated spectral diffusion due to the interaction with a bath of incoherent, low energy (EkBT) TLS ("thermal two-level fluctuators", TLF) that incoherently flip-flop between two states, giving rise to both noise and the coherent TLS width Γ2. Strongly coupled TLS contribute more strongly to the noise and they are also more easily saturated by microwave fields. In the weak microwave field regime (small 〈N〉) the magnitude of the noise is governed by the TLS dephasing rate Γ2T1+μ arising from the coupling to the TLF bath (and independent of the TLS relaxation rate Γ1), which yields a temperature dependence SyT−1−2μ11,20 (for kBT < hν0). Here μ is a small positive number characterising the density of states of TLS arising from their interactions. From the data in Fig. 3, we find μ = 0.25, consistent with previous experiments10,11,34. Since the magnitude and the temperature dependence of the noise are the same in vacuum and in 3He above 100 mK we conclude that 3He does not influence Γ2.

This leads to the remarkable conclusion that the enormous change in saturation power observed, Fig. 4a, reflects a 3He increase in the average TLS relaxation rate Γ1 ~ 1000 times, because the critical number of photons for saturation of the TLS bath scales as Nc Γ1Γ2.

We now turn to the low-temperatures regime, below Tx ~ 80 mK. First, we consider the implications of a significantly increased Γ1 of the TLS bath. In dielectrics, the TLS excitation and relaxation occur via interaction with phonons which couple via strain field. The relaxation rate can be expressed using the Golden rule formula as \({{{\Gamma }}}_{1}^{{{{{{{{\rm{ph}}}}}}}}}=({M}^{2}{{{\Delta }}}_{0}^{2}E)/(2\pi \rho {\hslash }^{4}{v}^{5})\times \coth \frac{E}{2{k}_{{{{{{\rm{B}}}}}}}T}\)41, where M is the deformation potential, Δ0 is the TLS tunnelling matrix element, E is the TLS energy, ρ is the density and v is the speed of sound of the material. For a resonator in a vacuum, the dissipation is through the emission of phonons into the dielectrics hosting the TLS, and at the relevant temperatures, this process is temperature independent with a rate that can be estimated to \({{{\Gamma }}}_{1}^{{{{{{{{\rm{ph}}}}}}}}}\,\approx \,1{0}^{2}-1{0}^{3}\) Hz20. This is much smaller than the TLS dephasing rate due to interactions Γ2: Previous estimates11,34 yielded Γ2 ≈ 106−107 Hz at T = 50−100 mK in similar devices.

Assuming the Γ2T1+μ dependence persists to lower temperatures means that in vacuum we would reach the regime of relaxation limited dephasing, Γ2 2Γ1, of the TLS bath below 10 μK, which is experimentally inaccessible. 3He immersion increases the average Γ1 to ~ 105 − 106 Hz, which shifts this crossover temperature to 10−100 mK. This agrees with the observed Tx ~ 80 mK in the noise and in the dependence of the quality factor on power Q(〈N〉). Furthermore, within the GTM \(1/{Q}_{i}\propto {{{{{{{\rm{\ln }}}}}}}}(c{N}_{{{{{{\rm{c}}}}}}}/\langle N\rangle )\)42, where c is a constant. The Q(〈N〉) data fits remarkably well to this logarithmic power dependence (see Supplementary Note 5). In Fig. 4c we show that the temperature dependence of cNc follows the predicted Nc Γ1Γ2(T) ~ T1+μ scaling at high temperatures. However, below Tx, this trend changes abruptly and becomes temperature independent. In the relaxation-limited regime, the noise is not expected to increase upon cooling, yet a temperature dependence may be inherited from mechanisms contributing to Γ1, such as the 3He–TLS interaction. 3He immersion thus prevents the TLS noise from rising more than three orders of magnitude upon cooling to 1 mK.

A second scenario that in addition may account for the apparent reduction in the noise is TLS saturation. Such a situation could arise because the measurement is conducted at a fixed driving power. As Γ2 (and hence Nc) reduces on cooling the applied power more easily saturates the TLS because they become more coherent20,43. The GTM predicts a universal T(1−μ)/2 = T0.375 scaling of the noise in this regime, and power broadening would also result in the observed crossover in Nc from T1+μ to constant in temperature42 (Fig. 4c) as for the relaxation limited scenario. Because we have significantly increased the average Γ1 of TLS in the bath, one would think that this scenario is of less relevance in 3He. Indeed, another important observation is that for saturation in the regime Γ1 Γ2 the crossover temperature Tx should depend on driving power, contrary to our data.

Yet, in any practical device the spatial variations in electric fields, the distribution of TLS parameters, and the fact that not all TLS are located in proximity to the exposed surface where they can couple to 3He means there still will exist TLS that are not suppressed by 3He and are therefore easily saturated. This prompts device improvements where surfaces and edges with strong electric fields should be placed in proximity to 3He.

As a first step to understand the 3He–TLS interaction, we note the long-standing problem of the thermal boundary resistance between solids and helium liquids, where the details of the interface, such as surface roughness44 and the nature of the surface boundary layer, including the presence of 1–2 atomic layers of solid helium at the interface due to van der Waals attraction45,46, play a key role47. Perhaps more closely related to this work are earlier acoustic and thermal measurements on strongly disordered48 and porous49,50 materials immersed in helium that also found evidence of faster TLS relaxation. It has been suggested51 that one mechanism by which phonons in helium couple to TLS is via van der Waals interaction. The upper bound for the relevant deformation potential in 4He was deduced to be M 2 meV48 compared to ≈ 1 eV for phonons in a solid. Using these numbers we can attempt to roughly estimate the enhanced TLS relaxation rate in 3He, compared to the sapphire substrate. For sapphire we use ρ = 4 × 103 kg/m3, v = 1 × 104 m/s, M = 1 eV. Similar values are also expected for TLS in the NbN surface oxide. For 3He we use ρ = 60 kg/m3, v = 200 m/s and M = 1 meV50. This yields \({{{\Gamma }}}_{1}^{3{{{{{{{\rm{He}}}}}}}}}/{{{\Gamma }}}_{1}^{{{{{{{{\rm{sap}}}}}}}}}\approx 1{0}^{4}\)—an order of magnitude larger than experimentally observed. This is not very surprising given the crudeness of the estimates and the fact that we measure the average for the whole TLS bath. Moreover, we note that below ~100 mK the propagating acoustic modes in 3He are that of zero sound52. Zero sound modes and the nuclear magnetism53,54,55 of 3He offer various interaction mechanisms with relevant degrees of freedom and a much richer spectrum of low energy excitations than in 4He56. To the best of our knowledge, the TLS–3He coupling has not been studied in detail before, and at low temperatures, other types of interactions may become as important as phonons, such as direct interaction between surface TLS and quasiparticles in 3He51,57.

Understanding the mechanism at play is crucial for future improvements, and two further experiments (details in Supplementary Note 4D and E) suggest that phonon relaxation into 3He following the Golden rule alone does not capture the full picture. (i) Measurements with only a thin (~4 nm) film of 3He covering the sample allow us to separate the two roles played by 3He, namely to enhance TLS relaxation and to mediate cooling. For a thin 3He film we still observe the big change in saturation power (3He–TLS interaction) but a plateaued noise as in a vacuum, indicating poor thermalisation. (ii) Increasing the pressure of the 3He to 5 bar, whereupon both ρ and v increase by ~30% compared to saturated vapour pressure56, should result in an almost five-fold reduction of Γ1. Contrary, we observed a very moderate increase in saturation power (<20%).

Finally, we turn to the dielectric properties of 3He to understand its compatibility with state-of-the-art qubit circuits. The resonator frequency shift due to filling the cell agrees with the 3He dielectric constant εr = 1.042658 within 1 part in 1000 (see Supplementary Note 4). Liquid 4He has a low-temperature dielectric loss tangent \(\tan \delta \, < \,5\times 1{0}^{-6}\) at 9 GHz59. Similar values are expected for 3He, however, to the best of our knowledge this value has not been reported at GHz frequencies. From the change in single-photon Qi at 10 mK as the cell is filled with 3He we estimate an upper bound for the loss tangent of \(\tan \delta \ll 1.5\times 1{0}^{-5}\) at 5.8 GHz, comparable to the best substrate dielectrics used. Likely \(\tan \delta\) is much lower as significant TLS-induced parameter drift occurs between measurements, the main source of error in our estimate. The bound on the loss tangent translates to a limit for qubit coherence times of T1 110 μs for a 6 GHz qubit, i.e. 3He is compatible with state-of-the-art quantum circuits. The potential impact of the nuclear magnetism of the solid 3He surface boundary layer on a qubit is an open question, addressable by its elimination through 4He plating53,60. Our immersion cell is compatible with quantum processor enclosure design principles and can straightforwardly be scaled to cells having large numbers of microwave ports.

In conclusion, we have shown that 3He is an efficient, low-loss cooling medium for quantum circuits and can cool down environmental degrees of freedom of the circuit: namely surface spins and the TLS bath. We also discovered the crucial role of 3He in suppressing the coherence of the TLS bath while otherwise being essentially inert to the circuit itself. Understanding the details of the mechanisms at play will require further theoretical and experimental work. The rich phase diagram of 3He provides an exciting playground for bath engineering of quantum circuits, with multiple in situ tuning parameters to unpick the underlying physical mechanisms. 3He immersion thus opens up a new avenue for exploring the origins of decoherence in quantum circuits and a promising pathway to further suppressing it, and our results show that 3He immersion cooling can be beneficial even at standard dilution refrigerator temperatures of 10 mK.

Methods

Experimental platform

To access temperatures below ~10 mK we mount the cell at the experimental plate of an adiabatic nuclear demagnetisation refrigeration stage fitted inside a dry dilution refrigerator. This allows to cool the experimental plate to ≈ 400 μK. Cooling to this temperature introduces a number of engineering challenges around our microwave readout setup, thermometry, and suppression of heat leaks from higher temperature stages in the cryostat. Here we summarise our solutions to these challenges and refer to Supplementary Note 1 for further details.

The circuit’s enclosure is well thermalised to the experimental plate of the ANDR via clean high conductivity copper links. The copper parts were not annealed to limit the eddy-current heating during ESR field sweeps. Compared to a typical vacuum enclosure with a well-controlled RF environment our immersion cell has several additional features: The cell is made completely leak-tight (superfluid tight) by the use of hermetic RF feed-throughs and indium seals. The cell is similar to that implemented in ref. 29 developed for low-temperature low-frequency transport measurements on quantum materials and devices, and the two cells share many features. As in ref. 29 the capillary connecting the cell to the 3He gas handling system was interrupted with a silver sinter filter. To thermalise the 3He liquid to the enclosure (and the ANDR experimental plate temperature) part of the cell’s internal volume is filled with silver sinter. Combined, these measures allow us to fill the cell with 3He and thermalise it to the experimental plate of the fridge. The experimental setup is carefully designed and screened such that at full field (6 T) the demagnetisation magnet only induces ~2 mT in plane stray field on the sample (deduced from ESR measurements). All measurements presented here were performed with the nuclear stage demagnetised to 35 mT, corresponding to 13 μT field at the sample. For details on the microwave setup and heat loads, we refer to Supplementary Note 1.

Thermometry

The temperature of the immersion cell (or any of its components) was not measured directly, but instead was deduced from a SQUID-read current sensing noise thermometer (CSNT) anchored to the ANDR experimental plate (details in Supplementary Note 1). CSNT allows us to accurately measure temperatures down to 100 μK61,62.

ESR measurements

We obtain the continuous wave ESR spectrum of the surface spins coupling to the resonators by measuring resonator transmission S21 at each magnetic field using a VNA. We fit this to S21(f) = 1−(1−Q/Qi)eiϕ/(1 + 2iQδf) with δf = (ν0f)/ν0 to extract the resonator’s center frequency ν0, coupled (Q) and uncoupled (Qi) quality factors, and a phase factor ϕ. From the uncoupled quality factor we then obtain the additional losses induced by spins coupling to the device as a function of the magnetic field: \({Q}_{{{{{{\rm{B}}}}}}}^{-1}(B)={Q}_{{{{{{\rm{i}}}}}}}^{-1}(B)-{Q}_{{{{{{\rm{i}}}}}}}^{-1}(B={B}_{{{{{{{{\rm{ref}}}}}}}}})\). Here Bref is the field the spectra is normalised to. We take the first few data points plus the last few data points as this reference. The latter is to better align the high field tail to better facilitate the comparison of the weak third peak. For each point in the magnetic field S21(f) of the resonator is measured at multiple excitation powers. Each magnetic field sweep takes about 8 hours, about half of the time is slow ramping of the magnet to minimise heating from eddy currents at the lowest temperatures, and during this time the temperature may drift as the nuclear stage warms up. We record the temperature during the measurement, and quoted temperatures in the figures are those relevant at the time of measuring specific features discussed.

To extract the hydrogen peak intensities in Fig. 3 we first fit the background to two broad Gaussians plus a Gaussian for the central peak (peak 2) while excluding the regions of the spectra containing the hydrogen peaks. We subtract this fitted background from the spectra and then finally fit two Gaussians to the two remaining hydrogen peaks. The error bars reported are 95% confidence bounds to these peak fits, which are propagated in the calculation of the normalised peak intensity.

Noise measurements

To measure the intrinsic 1/f noise of the resonators we use the Pound-locking technique63 to track the resonance frequency with high bandwidth. We record the gap-free time series of ν0(t) with a sampling rate of 0.05 s. We then analyse this time series to extract the 1/f noise magnitude from the overlapping Allan deviation. For the temperature sweeps presented in Fig. 2a we cool down the fridge to the lowest temperature and start recording ν0(t) as the fridge slowly warms up (over 6–7 days) to ~300 mK. We ramp the power applied to a heater to control the warm-up rate. The full time-series ν0(t) is then analysed piece-wise, in segments of 2 h, sufficient to obtain a clear 1/f noise contribution to the noise spectra. We indicate the temperature as the average temperature during this time interval, and error bars indicate the whole temperature range for the segment.

For a detailed description of the measurement technique, setup, analysis, and extended data, see Supplementary Notes 15.