Abstract
Conventional functional electrical stimulation aims to restore functional motor activity of patients with disabilities resulting from spinal cord injury or neurological disorders. However, intervention with functional electrical stimulation in neurological diseases lacks an effective implantable method that suppresses unwanted nerve signals. We have developed an electrochemical method to activate and inhibit a nerve by electrically modulating ion concentrations in situ along the nerve. Using ion-selective membranes to achieve different excitability states of the nerve, we observe either a reduction of the electrical threshold for stimulation by up to approximately 40%, or voluntary, reversible inhibition of nerve signal propagation. This low-threshold electrochemical stimulation method is applicable in current implantable neuroprosthetic devices, whereas the on-demand nerve-blocking mechanism could offer effective clinical intervention in disease states caused by uncontrolled nerve activation, such as epilepsy and chronic pain syndromes.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Katz, B. Society of Experimental Biology Symposia 4. Structural Aspects of Cell Physiology 16–38 (Cambrige Univ. Press, 1952).
Hodgkin, A. L. & Huxley, A. F. A quantitative description of membrane current and its application to conduction and excitation in nerve. J. Physiol. 117, 500–544 (1952).
Kandel, E. R., Schwartz, J. H. & Jessell, T. M. Principles of Neural Science (McGraw-Hill, 2000).
Brink, F. The role of calcium ions in neural processes. Pharmacol. Rev. 6, 243–298 (1954).
Brink, F., Bronk, D. W. & Larrabee, M. G. Chemical excitation of nerve. Ann. New York Acad. Sci. 47, 457–485 (1946).
Santini, J. T., Cima, M. J. & Langer, R. A controlled-release microchip. Nature 397, 335–338 (1999).
Chen, J. & Wise, K. D. Solid-State Sensor and Actuator Workshop 256–259 (Cleveland Heights, 1994).
Ammann, D., Buehrer, T., Schefer, U., Mueller, M. & Simon, W. Intracellular neutral carrier-based Ca2+ microelectrode with subnanomolar detection limit. Pfluegers Arch. 409, 223–228 (1987).
Baudet, S., Hove-Madsen, L. & Bers, D. M. in Methods in Cell Biology Vol. 40 (ed. Nuccitelli, R.) Ch. 4 (American Society for Cell Biology, Academic, 1994).
Bostock, H., Cikurel, K. & Burke, D. Threshold tracking techniques in the study of human peripheral nerve. Muscle Nerve 21, 137–158 (1998).
Bostock, H. & Grafe, P. Acitivity-dependent excitability changes in normal and demyelinated rat spinal root axons. J. Physiol. 365, 239–257 (1985).
Ask, P., Levitan, H., Robinson, P. J. & Rapoport, S. I. Peripheral nerve as an osmometer: Role of the perineurium in frog sciatic nerve. Am. J. Physiol. 244, C75–C81 (1983).
Weerasuriya, A., Spangler, R. A., Rapoport, S. I. & Taylor, R. E. AC impedance of the perineurium of the frog sciatic nerve. Biophys. J. 46, 167–174 (1984).
Bradbury, M. W. & Crowder, J. Compartments and barriers in the sciatic nerve of the rabbit. Brain Res. 103, 515–526 (1976).
Abbott, N. J., Mitchell, G., Ward, K. J., Abdullah, F. & Smith, I. C. An electrophysiological method for measuring the potassium permeability of the nerve perineurium. Brain Res. 776, 204–213 (1997).
Petruska, J. C., Hubscher, C. H. & Johnson, R. D. Anodally focused polarization of peripheral nerve allows discrimination of myelinated and unmyelinated fiber input to brainstem nuclei. Exp. Brain Res. 121, 379–390 (1998).
Manfredi, M. Differential block of conduction of large fibers in peripheral nerve by direct current. Arch. Ital. Biol. 108, 52–71 (1970).
Bhadra, N. & Kilgore, K. L. Direct current electrical conduction block of peripheral nerve. IEEE Trans. Neural Syst. Rehabil. Eng. 12, 313–324 (2004).
Tanner, J. A. Reversible blocking of nerve conduction by alternating-current excitation. Nature 195, 712–713 (1962).
Kilgore, K. L. & Bhadra, N. Nerve conduction block utilising high-frequency alternating current. Med. Biol. Eng. Comput. 42, 394–406 (2004).
Bhadra, N. & Kilgore, K. L. High-frequency nerve conduction block. Conf. Proc. IEEE Eng. Med. Biol. Soc. 7, 4729–4732 (2004).
Isaksson, J. et al. Electronic control of Ca2+ signalling in neuronal cells using an organic electronic ion pump. Nature Mater. 6, 673–679 (2007).
Olsson, Y. & Reese, T. S. Permeability of vasa nervorum and perineurium in mouse sciatic nerve studied by fluorescence and electron microscopy. J. Neuropathol. Exp. Neurol. 30, 105–119 (1971).
Waggener, J. D., Bunn, S. M. & Beggs, J. The diffusion of ferritin within the peripheral nerve sheath, an electron microscopy study. J. Neuropathol. Exp. Neurol. 24, 430–443 (1965).
Feng, T. P. & Liu, Y. M. The connective tissue sheath of the nerve as effective diffusion barrier. J. Cell. Physiol. 34, 1–16 (1949).
Krnjevic, K. The distribution of Na and K in cat nerves. J. Physiol. 128, 473–488 (1955).
Seneviratne, K. N. & Weerasuriya, A. Nodal gap substance in diabetic nerve. J. Neurol. Neurosurg. Psychiatry 37, 502–513 (1974).
Weerasuriya, A. Permeability of endoneurial capillaries to K, Na and Cl and its relation to peripheral nerve excitability. Brain Res. 419, 188–196 (1987).
Prodanov, D., Marani, E. & Holsheimer, J. Functional eletric stimulation for sensory and motor functions: Progress and problems. Biomed. Rev. 14, 23–50 (2003).
Mortimer, J. in Handbook of Physiology—the Nervous System II (eds Brookshart, J. M. & Mountcastle, V. B.) (American Physiology Society, 1981).
Kim, D. H. et al. Stretchable and foldable silicon integrated circuits. Science 320, 507–511 (2008).
Guenat, O. T. et al. Microfabrication and characterization of an ion-selective microelectrode array platform. Sens. Actuat. B 105, 65–73 (2005).
Acknowledgements
This work was conducted with support from a Massachusetts Institute of Technology faculty discretionary research fund, a Harvard Catalyst Grant from the Harvard Clinical and Translational Science Center (National Institutes of Health Award UL1 RR 025758) and financial contributions from Harvard University and its affiliated academic health-care centres.
Author information
Authors and Affiliations
Contributions
Y-A.S. carried out fabrication of ion-selective electrodes and membranes, experimental work and confocal imaging. R.M., A.N.R., A.M.S.I., D.M. and A.T. conducted experimental work and data analysis. J.H. and S.J.L. carried out project planning. A.N.R., Y-A.S., S.J.L. and J.H. wrote the manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors have applied for a patent based on the technique described in this paper.
Supplementary information
Supplementary Information
Supplementary Information (PDF 4090 kb)
Rights and permissions
About this article
Cite this article
Song, YA., Melik, R., Rabie, A. et al. Electrochemical activation and inhibition of neuromuscular systems through modulation of ion concentrations with ion-selective membranes. Nature Mater 10, 980–986 (2011). https://doi.org/10.1038/nmat3146
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/nmat3146
This article is cited by
-
A microscale soft ionic power source modulates neuronal network activity
Nature (2023)
-
Bionic iontronics based on nano-confined structures
Nano Research (2023)