Sir,
We read the article by Kim et al1 with interest and would like to highlight some concerns regarding their data and conclusions.
The title and purpose of the study seems to indicate outcomes for a particular surgeon group (residents in training); however, the conclusions are not supported by the data. Amongst 1582 procedures, after excluding surgery complicated with vitreous loss, 305/1582 procedures were performed by attending surgeons and further excluded from analysis. The outcomes of these 305 surgeries is reported in the discussion as having an incidence of first postoperative day intraocular pressure (IOP) elevation no higher than the trainee-performed surgery (P=0.94, χ2-test). The authors have surprisingly chosen to present the study as a consecutive case series instead of a more useful comparative study.
There is a discrepancy in the use of ophthalmic viscosurgical device (OVD). The methodology states use of two agents: Healon (1% sodium hyaluronate) initially in 2001 to 2005 and thereafter Duovisc, which is composed of two OVDs, the cohesive Provisc (1% sodium hyaluronate) and dispersive Viscoat (sodium chondroitin sulphate 4%–sodium hyaluronate 4%). However, in Table 2 the OVD reported as used is Healon GV, a hyaluronic acid product with a 10-times higher viscosity than Healon, preferred in complicated procedures (vitreous pressure, flat anterior chamber, so on) and thus probably chosen for resident surgery. The effect of OVDs with higher molecular weight and viscosity on postoperative IOP is well documented.2, 3 This may well explain the reason for this case series having a higher postoperative IOP 24 h after cataract surgery (22%, >23 mm Hg and 14.9%, >26 mm Hg) than the previously reported values of 2.57%4 and 11.8%,5 respectively.
The effect of trainee surgeons on early IOP rise after cataract surgery can be a consequence of relatively more manipulations, residual OVD, and subsequent increased inflammation. This hypothesis maybe better supported by data on central corneal thickness, aqueous flare, surgery duration, phacoemulsification power etc as well as a comparative case–control study design.
References
Kim JY, Jo M-W, Brauner SC, Ferrufino-Ponce Z, Ali R, Cremers SL et al. Increased intraocular pressure on the first postoperative day following resident-performed cataract surgery. Eye 2011; 25: 929–936.
Arshinoff SA, Albiani DA, Taylor-Laporte J . Intraocular pressure after bilateral cataract surgery using Healon, Healon5, and Healon GV. J Cataract Refract Surg 2002; 28: 617–625.
Thirumalai B, Blamires TL, Brooker L, Deeks J . Heavier molecular weight ocular viscoelastic devices and timing of post-operative review following cataract surgery. BMC Ophthalmol 2007; 7: 2.
Jaycock P, Johnston RL, Taylor H, Adams M, Tole DM, Galloway P et al. The Cataract National Dataset electronic multi-centre audit of 55,567 operations: updating benchmark standards of care in the United Kingdom and internationally. Eye 2009; 23: 38–49.
Browning AC, Alwitry A, Hamilton R, Rotchford A, Bhan A, Amoaku WM . Role of intraocular pressure measurement on the day of phacoemulsification cataract surgery. J Cataract Refract Surg 2002; 28: 1601–1606.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Chaudhary, R., Kadyan, A. First postoperative day intraocular pressure rise in resident-performed cataract surgery. Eye 26, 1026 (2012). https://doi.org/10.1038/eye.2012.70
Published:
Issue Date:
DOI: https://doi.org/10.1038/eye.2012.70