Abstract
Purpose
We report a novel technique characterized by sutureless scleral fixation of three-pieces foldable intraocular lens (IOL) using 25-gauge transconjunctival sutureless vitrectomy (TSV) trocars in patients with insufficient posterior capsule support.
Materials and Methods
We performed this technique on the eight eyes of the seven patients. The scleral tunnels (STs) are prepared by insertion of the 25-gauge TSV microcannulas using the trocars, and anterior vitrectomy is performed through the clear corneal paracentesis with the aid of anterior chamber maintainer (ACM). Finally, the three-piece foldable IOL haptics are incarcerated into the prepared STs.
Results
The patients were followed up 5–8 months. None of the patients had complications such as postoperative endophthalmitis, glaucoma, IOL tilt or decentralization, and retinal detachment. Injection of a foldable IOL through a clear corneal small incision also contributes the less surgical-induced astigmatism.
Conclusion
The presented novel sutureless scleral IOL fixation technique may provide minimal trauma to the surrounding tissues, good IOL stabilization decreasing the incidence of IOL tilt along with shorter operation time, and postoperative quiet eye.
Similar content being viewed by others
Introduction
In patients with insufficient posterior capsule support after cataract surgery, the different intraocular lens (IOL) implantation techniques have been used for optic rehabilitation.1, 2, 3, 4, 5, 6 However, the sutureless scleral fixation (SSF) of posterior camera (PC)-IOL implantation has become more popular.7, 8, 9, 10 Recently, Gabor and Pavlidis9 have first described a technique of SSF of PC-IOL. In this technique, IOL haptics are incarcerated into the prepared scleral tunnels (STs) and thus the stability of the PC-IOL is provided. Here, we have improved their previously described technique. In our technique, the ST are prepared by insertion of the 25-gauge transconjunctival sutureless vitrectomy (TSV) microcannulas using the trocars, and anterior vitrectomy is performed through the clear corneal paracentesis with the aid of anterior chamber maintainer (ACM). Finally, the three-piece foldable IOL haptics are incarcerated into the prepared ST.
Materials and methods
The peripheral cornea was marked with tissue pen at two points 180° apart using radial keratotomy marker (Figure 1a). Two transconjunctival ST, 1.5 mm from and parallel to the limbus, were then prepared with the 25-gauge TSV trocars, the entry sites of which exactly correspond to the previously marked points Image 1. During the tunnel preparation, the sclera was entered transconjunctivally with 10° angle using the 25-gauge TSV trocar preloaded with the overlying microcannula, and subsequently the trocar was removed leaving the microcannula in place (Figures 1b and c). An ACM was then placed and triamcinolone-assisted anterior vitrectomy was performed through clear corneal incision (CCI) (Figure 1d).
A standard IOL with propylene haptics was implanted with an injector through the CCI (Figures 2a and b). Then, a 25-gauge retinal forceps was entered into the PC through one of the prepared 25-gauge cannula whereas a 23-gauge retinal forceps was being entered into the anterior chamber through the paracentesis to grasp the contra-lateral IOL haptic. The grasped haptic was then approached to the 25-gauge forceps, which subsequently grasped the tip of the haptic. The haptic and 25-gauge cannula were together explanted from the sclerotomy simultaneously (Figures 3a–c). The same procedure was performed for the other haptic and microcannula (Figure 3d). The haptics were then properly placed into the ST by pushing their tips up to the trocar entry under the conjunctiva. The ST was closed with a 10/0 monofilament transconjunctival suture (Figure 4a). After the closure of the CCI with hydration, the operation was ended (Figure 4b). The placed transconjunctival suture was removed 1 week following surgery.
Results
We performed this technique (see Supplementary Video) on the eight eyes of the seven patients. The patients were followed up 5–8 months. None of the patients had serious complications such as postoperative endophthalmitis, glaucoma, IOL tilt or decentralization (Figure 5), and retinal detachment.
Discussion
The different IOL implantation techniques have been used in aphakic patients with insufficient posterior capsule support.5 Nowadays, the SSF of PC-IOL has become more popular.7, 8, 9, 10 In the SSF technique, described by Gabor and Pavlidis,9 IOL haptics are incarcerated into the prepared ST without sutures thereby allowing the stability confidently. This technique has been performed in the 66 patients with less trauma and scleral manipulation. They emphasized that ST incarceration of haptics provides IOL stabilization and decreases the incidence of IOL tilt.10 The suture-related complications of the conventional scleral IOL fixation technique are not encountered in the SSF technique.11 Injection of a foldable IOL through a CCI also contributes the less surgical-induced astigmatism.10 The incidence of chronic inflammation or recurrent bleeding is lower in the SSF technique than the other techniques. The PC-IOL implantation by the SSF technique also decreases the risk of intraoperative maneuvers and trauma.9
We applied Gabor and Pavlidis's9 technique in some patients. However, we have encountered some difficulty particularly during the haptic incarceration into the limbus-parallel ST because of the fact that a haptic tip externalized from the 24-gauge sclerotomy should be redirected in to the limbus-parallel 24-gauge ST at the same point. Therefore, we have developed our new technique in which the ST preparations and the haptics placements into the ST are more practical and safer.
Our technique also allows triamcinolone-assisted deep anterior vitrectomy by the aid of ACM and IOL injection in to the anterior chamber through the CCI. Therefore, the operation can be performed without any additional sclerotomy for vitrectomy before the PC-IOL implantation and for sustaining satisfactory globe maintenance during the surgery.12
In conclusion, the presented novel SSF IOL technique may provide minimal trauma to the surrounding tissues, good IOL stabilization decreasing the incidence of IOL tilt along with shorter operation time, and postoperative quiet eye.
References
Smiddy WE . Dislocated posterior chamber intraocular lens; a new technique of management. Arch Ophthalmol 1989; 107: 1678–1680.
Nabors G, Varley MP, Charles S . Ciliary sulcus suturing of a posterior chamber intraocular lens. Ophthalmic Surg 1990; 21: 263–265.
Azar DT, Wiley WF . Double-knot transscleral suture fixation technique for displaced intraocular lenses. Am J Ophthalmol 1999; 128: 644–646.
Baykara M, Ozcetin H, Yilmaz S, Timuçin OB . Posterior iris fixation of the iris-claw intraocular lens implantation through a scleral tunnel incision. Am J Ophthalmol 2007; 144: 586–591.
Dick HB, Augustin AJ . Lens implant selection with absence of capsular support. Curr Opin Ophthalmol 2001; 12: 47–57.
Menezo JL, Martinez MC, Cisneros AL . Iris-fixated Worst claw versus sulcus-fixated posterior chamber lenses in the absence of capsular support. J Cataract Refract Surg 1996; 22: 1476–1484.
Agarwal A, Kumar DA, Jacob S, Baid C, Agarwal A, Srinivasan S . Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules. J Cataract Refract Surg 2008; 34: 1433–1438.
Prakash G, Agarwal A, Jacob S, Kumar DA, Chaudhary P, Agarwal A . Femtosecond-assisted descemet stripping automated endothelial keratoplasty with fibrin glue-assisted sutureless posterior chamber lens implantation. Cornea 2010; 29: 1315–1319.
Gabor SG, Pavlidis MM . Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg 2007; 33: 1851–1854.
Scharioth GB, Prasad S, Georgalas I, Tataru C, Pavlidis M . Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg 2010; 36: 254–259.
Por YM, Lavin MJ . Techniques of intraocular lens suspension in the absence of capsular/zonular support. Surv Ophthalmol 2005; 50: 429–462.
Kumar DA, Agarwal A, Jacob S, Prakash G, Agarwal A . Use of 23-gauge or 25-gauge trocar cannula for globe maintenance in glued intraocular lens surgery. J Cataract Refract Surg 2010; 36: 690–691.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Additional information
Supplementary Information accompanies the paper on Eye website
Supplementary information
Rights and permissions
About this article
Cite this article
Totan, Y., Karadag, R. Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation. Eye 26, 788–791 (2012). https://doi.org/10.1038/eye.2012.19
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/eye.2012.19
Keywords
This article is cited by
-
A comparative study of transscleral sutured intraocular lens fixation and sutureless flanged intraocular lens fixation
BMC Ophthalmology (2023)
-
Intraocular lens implantation in the absence of capsular support: scleral fixation
Eye (2022)
-
Two-year results of a novel sutureless scleral fixation surgery with the haptic hook technique
Graefe's Archive for Clinical and Experimental Ophthalmology (2022)
-
Sutureless scleral fixation Carlevale IOL: a review on the novel designed lens
International Ophthalmology (2022)
-
Pole to Pole Surgery in Ocular Trauma: Standardizing Surgical Steps
Ophthalmology and Therapy (2022)