Abstract
The surgical correction of spinal deformities carries a small but significant risk of injury to the spinal cord. To detect the onset and possibly reverse the effects of surgical complication, a variety of neurophysiological monitoring procedures can be employed. The purpose of this review is to provide information regarding the various methodologies available for monitoring spinal cord and nerve root function during orthopaedic procedures. Intra-operative monitoring of cortically recorded somatosensory evoked potentials (SEPs) by peripheral nerve stimulation is of value during orthopaedic surgery and is the state-of-the-art in terms of non-invasiveness, versatility, time requirement, lateral discrimination, and ease of electrode placement. Monitoring of motor evoked potentials (MEPs) is useful particularly in combination with SEPs but is still considered investigational. Root function monitoring has limited application and requires more clinical research.
Spinal Cord (2000) 38, 133–139.