Introduction

Glaucoma is one of the leading causes of loss of sight in the world1,2. Glaucoma is a progressive and irreversible optic neuropathy which can result in irreversible visual field (VF) damage and it is therefore essential to accurately predict future VF progression when making glaucoma treatment decisions. Future VF deterioration is usually predicted by applying ordinary least squares linear regression (OLSLR) to global VF indices such as mean deviation (MD), as in the Guided Progression Analysis™ (GPA) software on the Humphrey Field Analyzer (HFA, Carl Zeiss Meditec AG, Dublin, CA, USA). We have reported several alternative approaches to improve the prediction accuracy of VF progression, such as robust regression3, least absolute shrinkage and selection operator (Lasso) regression4, cluster-wise regression5,6, and also variational Bayesian linear regression7. In addition, many other successful efforts have been reported from other researchers8,9,10,11,12,13,14, nonetheless ordinary OLSLR is still very frequently used at the clinical setting. One thing that all these approaches have in common is that VF progression is predicted using only VF measurements; however, other parameters are routinely captured in the clinic which may be useful to supplement any model of VF progression. In particular, previous studies strongly suggest that intraocular pressure (IOP) is closely related to VF deterioration15,16,17,18,19 and indeed, glaucoma management is usually focused on adequately controlling IOP, nonetheless there is no method to predict VF progression in which both of VF and IOP records are concurrently considered. In the current study, a novel VF trend analysis is carried out by integrating time (the standard independent variable in VF trend analyses) with IOP measurements; we simply multiple time by IOP when this measurement is available. We term this approach ‘IOP-integrated VF trend analysis’ and here we compare the prediction accuracy of the method against the standard VF trend analysis.

Method

The review board of the University of Tokyo, Osaka University Graduate School of Medicine, Shimane University Faculty of Medicine, Matsue Red Cross Hospital, Ehime University Graduate School of Medicine, Kyoto Prefectural University of Medicine, Yamaguchi University Graduate School of Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, and University of Yamanashi Faculty of Medicine, Kitasato University reviewed and approved all protocols. The study complied with the tenets of the Declaration of Helsinki. Written consent was given by patients for their information to be stored in the hospital database and used for research or shown posted at the outpatient clinic to notify the participants of the study, based on the regulations of the Japanese Guidelines for Epidemiologic Study 2008 issued by the Japanese Government.

Subjects

Subjects and visual fields

VF data were retrospectively obtained from a total of 481 eyes in 309 patients with open angle glaucoma and ten eyes from eight patients with exfoliation glaucoma. All of the data in the current study were collected in the JAMDIG study (Japanese Archive of Multicentral Databases in Glaucoma)4 in which nine institutes in Japan were involved. Each eye was VF tested at least 10 times, excluding the first VF (for learning effects). Diagnosis of glaucoma was determined when the following findings were present: 1) presence of typical glaucomatous changes in the optic nerve head, such as a rim notch with a rim width ≤0.1 disc diameters or a vertical cup-to-disc ratio of >0.7 and/or a retinal nerve fiber layer defect with its edge at the optic nerve head margin greater than a major retinal vessel, diverging in an arcuate or wedge shape. VF measurements were performed using the HFA with either the 30-2 or 24-2 program and the Swedish Interactive Threshold Algorithm Standard, but only the 52 test locations overlapping with the 24-2 test pattern were used in the analyses when VFs were obtained with the 30-2 test pattern. Other inclusion criteria were best corrected visual acuity better than 6/12, refraction within ±6 diopter ametropia, no previous ocular surgery except for cataract extraction and intraocular lens implantation, and no other anterior and posterior segment of the eye disease that could affect the VF, including cataract other than clinically insignificant senile cataract. Reliability criteria for VFs were applied: fixation losses less than 20% and false-positive responses less than 15% following the criteria used by the HFA software; false negatives (FN) were not used in as an exclusion criterion20. The VF of a left eye was mirror-imaged to that of a right eye for statistical analyses. Eyes that did not have at least seven IOP measurements were removed from the analysis.

Statistical analysis

Standard VF trend analysis

First, a conventional trend analysis was conducted on each series. Linear regressions were carried out using measurements in the first five VFs (VF1-5) to predict the corresponding measurement in the tenth VF (VF10) for: (i) point-wise total deviation (TD) values and (ii) mean of 52 TD values correspond to HFA 24-2 VF (mTD). Then the difference between the predicted value and the actual value in VF10 was calculated. The same procedure was iterated using different lengths of VF series for the predictions: VF1-6, VF1-7, VF1-8 and VF1-9. Prediction accuracy was compared using the absolute prediction error for mTD value and root mean squared error (RMSE) for point wise TD value:

IOP-integrated VF trend analysis

As shown in Fig. 1, the time from the baseline VF was integrated using IOP measurements. This is a simple calculation of the time multiplied by the IOP value. Figure 1a shows a case example. The top figure shows the time trend analysis in which VF measurements were regressed against time (year). The middle line graph shows the measured IOP values while the bottom figure shows the time integrated time trend analysis in which VF measurements were regressed against time IOP (daysmmHg). Figure 1b shows a simulated case for the same case example, assuming measured IOP values were 5 mmHg until 2008/9/29 and 30 mmHg after that date. The top figure shows the IOP integrated time trend analysis and the middle figure is a line graph of the simulated IOP values. If an IOP measurement was not carried out on the date of VF measurement, as is often experienced in the real world clinic, then an IOP for that date was calculated using a linear interpolation of IOP values at the last and next IOP measurement (see Fig. 2). If there were more multiple IOP records between VF measurements, the IOP-integrated time value was calculated for each IOP interval. IOP was always measured with Goldmann tonometry. Linear regression was then performed just like a conventional VF trend analysis; only the IOP-integrated time value was used as the independent variable, instead of time. RMSE and absolute prediction errors associated with point wise and mTD regressions were then calculated as before using VF1-5, VF1-6, VF1-7, VF1-8 and VF1-9.

Figure 1: Calculation of IOP-integrated time.
figure 1

IOP-integrated time was calculated by integrating IOP. (a) A case example. The top figure shows the time trend analysis in which VF measurements were regressed against time (year). The middle line graph shows the measured IOP values and the bottom figure shows the time integrated time trend analysis. (b) Simulated example assuming measured IOP values were 5 mmHg until 2008/9/29 and 30 mmHg after that date. The top figure shows the the line graph of the simulated IOP values and the middle figure shows time integrated time trend analysis. IOP: intraocular pressure, VF: visual field.

Figure 2: Imputation of missing IOP value on the VF measurement day.
figure 2

In this case, VF was measured on days 0, 300 and 500. An IOP measurement was missing on day 300 so the value was imputed using linear interpolation, IOP: intraocular pressure, VF: visual field.

The absolute prediction errors for each trend method were compared using linear mixed modelling, whereby patients were treated as a ‘random effect’. Furthermore, the relationship between (i) the IOP measurement interval and (ii) mean IOP, and prediction errors was also investigated using the linear mixed model.

All analyses were performed using the statistical programming language ‘R’ (R version 3.1.3; The Foundation for Statistical Computing, Vienna, Austria).

Result

Characteristics of the study population are summarized in Table 1. The average mTD at baseline was −6.7 ± 6.2 dB (mean ± standard deviation) and the mean initial patient age was 54.6 ± 12.0 years. The average progression rate of mTD was −0.16 ± 0.42 dB/year. IOP was measured 24.0 ± 8.5 times in 5.5 ± 1.2 years. The mean ± standard deviation of IOP measurements was 13.6 ± 2.2 mmHg.

Table 1 Subject demographics.

Figure 3 shows the absolute mTD prediction errors associated with the conventional trend analysis as well as the IOP-integrated VF trend analysis. The absolute prediction errors were significantly smaller for the latter approach when VF1-6 through to VF1-8 were used in the prediction (P = 0.0037, 0.0410, 0.0062, linear mixed model).

Figure 3: The absolute mTD prediction errors associated with a standard trend analysis and the IOP-integrated VF trend analysis.
figure 3

*p < 0.05, **p < 0.01, IOP: intraocular pressure, mTD: mean of 52 total deviation values correspond to 24-2 Humphrey visual field.

Figure 4 shows the RMSEs associated with both trend methods when predicting point-wise TD values. The RMSEs with the IOP-integrated VF trend analysis were significantly smaller than those from the standard analysis when VF1-6 through to VF1-9 were used for prediction (P = 0.0022, 0.0216, 0.0057, 0.048, linear mixed model).

Figure 4: The RMSEs associated with the standard trend analysis and the IOP-integrated VF trend analysis using point-wise mTD values.
figure 4

*p < 0.05, **p < 0.01. OLSLR: ordinal least square regression, IOP: intraocular pressure, PW: point wise, mTD: mean of 52 total deviation values correspond to 24-2 Humphrey visual field.

Table 2 summarizes the difference between the absolute mTD prediction errors obtained with both trend analyses, and the relationship between this difference and the IOP measurement interval and mean IOP. As can be seen in Table 2, there was a significant relationship between the magnitude of the difference and IOP measurement interval for VF1-6 and VF1-7 (p = 0.014 and 0.0077, respectively, linear mixed model). The relationship approached significance (p value of 0.0503) for VF1-5. No significant relationship was observed between the magnitude of the difference in errors and mean IOP (p > 0.05, linear mixed model).

Table 2 Difference in absolute mTD prediction errors from each approach, and the relationship between the magnitude of the difference and IOP measurement interval and mean IOP.

Discussion

In this study, a novel VF trend analysis was proposed that considers IOP measurements in the regression. A significantly smaller prediction error was observed for this approach compared to a standard time trend analysis. Furthermore, the method appears not to be significantly affected by the level of IOP or progression rate. However, despite a significant reduction in prediction error, the magnitude of this improvement is small relative to previous novel regression models that use only VF data3,4,5,6,7,8,9,10. One of the possible reasons for such a small improvement is that IOP fluctuates in the short and long term21 and measuring IOP at the clinic in approximately three month intervals is too infrequent to observe the true trend in IOP. In addition, the magnitude of the interval between VF tests may be directly related to the previous IOP measurement (a person with high IOP is likely to be seen again sooner), and hence the influence of IOP is already reflected to some extent in the standard trend analysis.

It should be noted that the VF data analyzed in this study was obtained from real world clinics. The mean VF progression rate in the current study was −0.16 dB/year with a mean IOP of 13.6 mmHg, suggesting IOP was, in general, well-managed. A further study should be carried out using a dataset with a faster average progression rate and also a higher average IOP.

It has been suggested that glaucomatous optic disc change occurs as a result of the difference between IOP and cerebrospinal pressure22, although this hypothesis remains controversial23. We carried out a further trend analysis using IOP subtracted cerebrospinal pressure (the IOP value was subtracted from the average cerebrospinal pressure in a normal population, calculated as the mean of the upper and lower limits for normal range cerebrospinal pressure), however, no further improvement of prediction error was observed (data not shown). In addition, corneal thickness and corneal hysteresis are closely related to Goldmann tonometry measurements24,25,26,27,28 and also VF progression29,30. A future study should be carried out using IOP measurements that have been adjusted for these factors. A previous study reported that incorporating other risk factors, namely mean IOP, central corneal thickness, and presence of progressive optic disc damage, resulted in a marked improvement in the prediction of VF progression31. The improvement in the current study was much smaller than this previous report, however, the virtue of the approach outlined is its simplicity: the standard linear regression model is all that is needed, whereas a Bayesian modelling approach was implemented in the previous study.

We observed that the difference between absolute mTD prediction errors obtained with the standard trend analysis and the IOP-integrated VF trend analysis were larger when the IOP measurement interval was greater. Thus, it appears that measuring IOP more frequently is advantageous when predicting future VF progression. IOP is known to change every day and throughout the day32,33. It would be interesting to see whether including several IOP measurements throughout the day, such as IOP monitoring for 24 hours32,33, would improve the results. We noted that absolute mTD prediction errors obtained with standard trend analysis were larger than those from the IOP-integrated method when the progression rate was fast (data not shown). This is likely because VF progression is related to IOP level as suggested by numerous previous studies34. Various methods have been proposed to measure VF progression in glaucoma patients3,4,7,9,11,12,13,14,35,36, however, simple time trend analysis remains the standard in clinical settings. Hence we compared the prediction performance of the IOP integrated trend analysis against the standard approach. It should be further investigated whether combining the current approach with other novel regression models further improves prediction accuracy. In addition, linear interpolation was used to calculate the missing IOP using the IOP values at the last and next IOP measurement (see Fig. 2). Other methods could give more accurate estimation, such as spline interpolation, and the effect of the interpolation methods on the prediction accuracy of the VF sensitivity should be carried out in a future study, although this effect may be small, having the stable IOP control (13.6 ± 2.2 mmHg) under the treatment.

In conclusion, we have demonstrated a simple method to incorporate IOP control in VF trend analysis. As a result, a statistically significant improvement in prediction was observed.

Additional Information

How to cite this article: The Japanese Archive of Multicentral Database in Glaucoma (JAMDIG) construction group. A novel method to predict visual field progression more accurately, using intraocular pressure measurements in glaucoma patients. Sci. Rep. 6, 31728; doi: 10.1038/srep31728 (2016).