Introduction

Common imaging tools to assess the mineral content in human tissues, such as bone and teeth, use ionizing radiation, which is associated with a health risk1. As the mineral component largely consists of calcium phosphates the imaging of phosphorus by MR represents a direct view on the mineral content in these tissues without ionizing radiation2,3,4,5. However, the application of 31P MR imaging to examine rigid structures such as bones and teeth is hampered by several factors affecting signal strength.

A major challenge in 31P MRI of bone and teeth is the rapid signal loss after excitation due to the ultra-short T2* relaxation time of the 31P signals from mineral5. To avoid this loss the 31P signal must be acquired by MR pulse sequences with minimal delay between the excitation of spins and start of data sampling (‘dead time’ or ‘echo time’). Clinically relevant MRI sequences that accommodate minimal dead times are UTE (Ultra-short echo time)6,7, SWIFT (SWeep Imaging with Fourier Transformation)8 and ZTE (Zero Echo Time)9,10,11. The lower intrinsic MR sensitivity and slower longitudinal relaxation times of 31P spins compared to 1H spins are additional challenges to perform 31P MRI of bones and teeth. One way to enhance the 31P signal is by generating a 1H–31P nuclear Overhauser effect (NOE)12, from which also structural information can be obtained. The NOE has not been applied yet to MRI of mineralized tissue.

In this study we performed 3-dimensional 31P MRI with 1H-31P NOE to obtain anatomical and structural information of mineral tissue of human teeth as a model system with known phosphorous content in distinct anatomical regions. We adapted SWIFT and ZTE pulse sequences and the MR system hardware for NOE enhanced 31P MRI at a minimized ‘dead time’ and determined the structural origin of the NOE by solid-state NMR of mineral samples from teeth.

Results

Phosphorus MRI by ZTE and SWIFT pulse sequence

For reference purposes, we first subjected a human maxillary left second molar tooth (Fig. 1A) to 1H MR imaging. In the images several anatomical features, such as dentin, enamel and pulp tissues can be distinguished (Fig. 1B). The hyperintense regions on the surfaces of the tooth are due to water present in the residual connective tissue attached to the mesiobuccal root, namely the periodontal ligament and free water in the occlusal pits. From the 1H MR image in the apical-coronal direction, it is clear that enamel exhibits less intense signal than dentin (Fig. 1D).

Figure 1
figure 1

Photograph (A) and selected slices of 3D MR images of human maxillary left second molar tooth (BF) including SWIFT 1H images (B,D), SWIFT 31P images (C,E) and ZTE 31P image (F) presenting axial (B,C) and apical (DF) slices. The position of apical slices (DF) is represented by the yellow line in image B. In the images of this slice, dentin and enamel are clearly separated. Image acquisition times were 100 s (B,D), 60 s (C) and 14  min (E,F).

In order to optimize the pulse sequence for 31P MRI of teeth, we measured the relaxation times of 31P nuclei: the global (whole tooth) T2* of 31P was ≈100 μs and the global T1 was ≈130 seconds for this human maxillary left second molar tooth. For other teeth samples, similar T2* values were obtained and T1 values were all within the range of 100–200 seconds. In 31P MR images obtained in 100 seconds by SWIFT and ZTE (512 spokes), the contour of the molar tooth is already visible (Fig. 1C). In the higher resolution 31P MR image acquired in 14 minutes (4096 spokes, equal to a nominal resolution of approximately 0.5 mm)6, better delineation between structures with more details can be seen: for example, in cross-sectional slices enamel with higher phosphate content shows a higher signal intensity compared to dentin (Fig. 1E,F). The average signal-to-noise ratio (SNR) of the 31P signal of enamel is about 50% higher than that of dentin.

In general, the 31P MR images obtained with ZTE offer better SNR than those obtained with the gapped SWIFT sequence (compare Fig. 1E with 1F). The global SNR of the SWIFT images is 28% lower than the ZTE images (18.2 versus 25.3).

For an investigation of the complementary anatomical information obtained by 1H MRI and 31P MRI we examined three differently affected teeth (Fig. 2). In the 1H MR image of a maxillary right second molar, the dentin and pulpal tissues are clearly separated: the pulpal tissues show much higher signal intensity compared to the dentin. In contrast, the 31P MR image shows a void for the pulpal tissue, due to a much lower phosphate content (mainly phospholipids in nerves, vessels, etc.) and dentin is visible as a hyperintense region (Fig. 2A). In the 1H MR images of a mandibular right first premolar (Fig. 2B), the buccal pit and distolingual carious lesions in the crown are clearly visible because of the increased water content in these lesions (Fig. 2B top). Complementary, the 31P MR image identifies mineral breakdown in this area (Fig. 2B bottom). For the maxillary left canine, a composite restoration at the mesiolingual surface of the tooth is responsible for the hypointense region (dashed curves in yellow dashed curve) observed on the 1H MR image (Fig. 2C top). The 31P MR image better represents the structure of the canine by showing its mineral content (Fig. 2C bottom).

Figure 2
figure 2

Comparison for 1H (top) and 31P (bottom) SWIFT MR images of three different teeth including human maxillary second molar (A), mandibular right first premolar (B) and mandibular left canine (C). The premolar contained a defect with high water content (red arrow); the left canine contains a restoration (yellow dashed curves).

NOE enhancement in 31P MRI

Irradiation at the 1H frequency generates a positive NOE for the 31P MR signal of teeth (Fig. 3). The global NOE enhancement in the 31P MR images is around 20% (an SNR of 21.8 in SWIFT MR images with NOE versus 18.2 without NOE, measured over the whole object). This enhancement is not the same for all regions: subtraction of the SWIFT MR images with and without NOE clearly reflects the shape of dentin, while enamel is less intense in the subtraction image (Fig. 3C). The estimated NOE enhancement for dentin and enamel from these images is about 20% and 4% respectively.

Figure 3
figure 3

Selected slices of 3D 31P MR images of maxillary left second molar tooth obtained with the SWIFT sequence.

(A) SWIFT image obtained with irradiation at the 1H frequency for 1.282 s, preceded by 64 dummy scans to reach steady state. (B) MR image of same slice obtained without 1H irradiation. (C) The subtraction of A and B shows a positive NOE in particular for signal coming from dentin. The yellow dash-dot line represents the contour of the enamel.

Solid-state spectroscopic studies of 1H-31P NOE of teeth

To investigate the origin of the 1H-31P NOE enhancements in teeth, we performed solid-state NMR spectroscopy on separated dentin and enamel materials. In 1H magic angle spinning (MAS) NMR spectra of both enamel and dentin, the water resonance at ≈5 ppm is the most pronounced signal (Fig. 4A). In enamel, a characteristic resonance for the hydroxyl group in hydroxyapatite arises at around ~0.1 ppm, while no signal can be seen at this chemical shift for dentin (Fig. 4A). The other resonances in dentin arise from the organic matrix13,14. The 31P MAS spectrum shows lower signal intensity for dentin compared to enamel (Fig. 4B). The 31P spectrum of dentin and enamel were deconvoluted based on previous studies (Fig. 4C,D). For dentin, two components are assigned for a crystalline and an amorphous phase15. For enamel, a three-component model is used. The central line is assigned to interior phosphate groups. The shoulders have been assigned to unprotonated and protonated phosphate surface groups16. The different components constituting the phosphorus spectrum behave similarly in the NOE build-up.

Figure 4
figure 4

1H MAS spectra (νr  = 35 kHz, A) and 31P MAS spectra at (νr = 10 kHz, B) of dentin (blue lines) and enamel (green lines), the spectra are recorded with the same parameters and processed in the same way. The height of the spectrum is scaled normalized to the sample weight, allowing for a semi-quantitative judgment. Deconvolution of the dentin 31P signal (C) and the enamel 31P signal (D) using two and three components12,13.

The 1H-31P NOE enhancement as a function of the saturation time can be fitted by mono-exponential functions and shows a clear difference in the NOE build-up for dentin and enamel (Fig. 5). At the longest used 1H irradiation time of 500 s the NOE plateaus at 31% for dentin, but for enamel this plateau is not yet reached with an enhancement of 14%. Extrapolation of the build-up curve for enamel indicates a plateau at 19%. The NOE build-up rate in dentin is faster than in enamel with rate constants of about 116 s and 310 s respectively (Fig. 5).

Figure 5
figure 5

Measured NOE build-up of the 31P signal of dentin (blue) and of enamel (red) as a function of 1H saturation time. The dashed lines represent mono-exponential fits to the data points.

The results of 1H → 31P cross-polarization (CP) experiments are presented in Fig. 6. The dentin polarization reaches a maximum at ≈3 ms CP contact time; then this polarization decreases and the signal intensity further decays at longer contact times (Fig. 6A). Enamel polarizes slower: the build-up of the CP signal intensity only reaches its maximum intensity after 8 ms; and there is no prominent decrease even until 15 ms (Fig. 6B). A comparison of the 1H → 31P CP spectra of dentin at short and long contact times shows that the 31P line shape of dentin observed at long CP contact times is narrower (Fig. 6C) and similar to the line shape observed in the 31P and NOE enhanced 31P spectra.

Figure 6
figure 6

Array of CP spectra at different contact times for dentin (A) and enamel (B). Comparison of the line shapes of the 1H → 31P CP spectra of dentin at short and long contact times (C).

Discussion and Conclusion

In this study we realized 3-dimensional 31P MR imaging of human teeth down to nominal resolutions of about 0.5 mm in measurement times below 15 minutes showing resolved dentin and enamel structures. In the images of diseased teeth spatially reduced phosphate contents were observed complementary to lesions seen in 1H MR images obtained with the same probe. The 31P MR signal in teeth can be enhanced by the 1H-31P NOE, which also provides an option for additional imaging contrast as the NOE is different for dentin and enamel. Solid state NMR revealed that the origin of this difference in NOE is the higher water content and different microstructure of dentin.

It is attractive to use 31P MR imaging for direct spatial information on the mineral content of teeth and bone as the major component is hydroxylapatite (Ca10(PO4)6(OH)2)17. However, MRI of 31P in human mineralized tissue is challenging, owing to its low MR sensitivity and very long T1 and short T2* relaxations. To deal with the short signal persistence after excitation we implemented hardware for rapid switching between excitation and receive mode and ZTE and SWIFT sequences for immediate signal acquisition. The SNR of SWIFT images is expected to be lower compared to images obtained by ZTE due to gapped acquisition and is proportional to the square root receiver duty cycle drec(=0.5 in this study). This is in agreement with experimental findings: . However, SWIFT requires less RF peak power, which is an advantage over ZTE for in vivo imaging. A recent modification of SWIFT, multi-band SWIFT, allows for a highly increased receiver duty cycle18. Both methods, ZTE and SWIFT, are becoming more widely available and have potential for 31P MRI of human bone and teeth. Various 31P MRI methods have been used to assess mineralization of bone, including a solid-state method similar to ZTE for human teeth19,20,21. In the present study we obtained a higher resolution, clearly resolving dentin and enamel, at shorter acquisition times.

The NOE is the fractional change in the integrated NMR absorption intensity of a nuclear spin system upon saturation of neighbor-coupled spins22. 31P NOE enhancement by 1H irradiation has been widely reported for phosphate compounds in solutions23,24, but never in human mineralized tissue. In this study, a positive 1H-31P NOE enhancement of the signal intensity in 31P MR images is observed. More importantly, the enhancement for enamel and dentin is different. Steady state NOE experiments show that the enhancement reaches its maximum value with 1H RF irradiation lasting about 5 × T1 of 31P spins, in agreement with our knowledge of heteronuclear NOE in the solid state25.

NOE and CP both rely on the dipolar interaction. As the phosphate structures in enamel and dentin are chemically very similar no big changes in the static dipolar interactions are expected. However, molecular motions will modulate the dipolar interactions and therefore affect CP and NOE efficiency. Different microstructures of chemically related moieties can therefore still give different CP and NOE response. The difference in microstructure of enamel and dentin is clearly reflected in the CP dynamics. CP is a coherent polarization transfer process and is very sensitive to motions in the kHz regime of the involved spins. The slower build-up in enamel most likely results from much lower relative 1H content in enamel compared to dentin. The change in line-width in the 31P CP spectra at longer contact times indicates that the materials consist of various components showing different dynamics. In dentin, the broader line-width at short contact times is attributed to a more heterogeneous, amorphous environment26,27,28.

To identify differences in NOE build-up for the various components of enamel and dentin, the NOE enhanced 31P spectra were deconvoluted according to the number of components used in literature14,15. However, within the error of the analysis, all individual components in enamel and dentin show similar enhancement and build-up dynamics. We attribute this to 31P spin diffusion (neighboring spins exchange polarization via dipolar couplings) taking place during the build-up process over hundreds of seconds. The NOE effect is a cross-relaxation effect, which requires a modulation of the dipolar interaction at the nuclear Larmor-frequency to be efficient. Therefore fast motions with correlation times in the ns regime must be present. The OH concentration in enamel is much higher than in dentin, but the strongest enhancement is observed in dentin. This indicates that the hydroxyl resonance is not the main contributor to the NOE mechanism. As the water resonance around 5 ppm is a common feature and remains even after extensive drying29, water appears to be strongly adsorbed to the minerals. This is in agreement with the observation that the NOE persists after drying. The water resonance is more pronounced in dentin, which is consistent with the higher enhancement observed and is therefore the most plausible source of the NOE. The structural role of water in bio-minerals is still under investigation30.

We tried to identify the 1H resonance involved in the NOE by 1H saturation at selective frequencies, but no significant differences in the enhancement were observed (data not shown). It is virtually impossible to selectively saturate a single proton resonance as during the long NOE build-up period (hundreds of seconds), irradiating at a single frequency, spin diffusion will effectively equilibrate all polarization. This is in agreement with experiments on synthetic apatite, where all proton resonances show spin exchange within milliseconds31. Since the NOE enhanced 31P spectra of dentin resemble it’s CP spectra at long polarization times (reflecting the crystalline phase remote from protons), it is most probable that the more pronounced and faster NOE build-up in dentin arises in the amorphous phase and is then transferred by spin diffusion to the crystalline phase.

A difference in dentin and enamel microstructure most likely explains the faster and more pronounced NOE in dentin: enamel consists mainly of highly crystalline apatite mineral (96 wt%), while dentin, besides being partly amorphous, also contains an organic matrix and water (i.e. type I collagen fibrils at around 20 wt% and hydration/interstitial water 10 wt%)32. High frequency motions modulating the 1H-31P dipolar interactions are most likely to occur in these phases.

Compared to 3D imaging with cone-beam computed tomography, 31P MRI uses no ionizing radiation and it can be combined with 1H MRI for the visualization of calcified dental tissue. Additionally 31P MRI has an advantage of being a true volumetric method. Although the current results suggest some favorable prospects for biomedical applications, the realization of 31P MRI for human bone imaging to address clinical questions faces a number of challenges33. In this respect it is of interest that the RF duty cycle for 1H irradiation in the current NOE experiments was less than 5%, while much higher duty cycles for 1H-31P NOE of the human brain have been safely applied at 7T field strength34.

In conclusion, we demonstrate that 3D 31P MR images of teeth can be obtained by SWIFT and ZTE pulse sequences with minimum transmit/receive deadtime, in which dentin and enamel are spatially resolved. We showed that irradiation at the 1H frequency creates NOE enhancement of the 31P signal in these images. The signal of dentin is more enhanced than that of enamel which is caused by micro-structural differences. Thus the NOE provides an option for additional structural imaging of teeth. This new approach may also have potential in the assessment of other mineralized tissues in the human body, such as monitoring mineral changes due to osteoporosis.

Materials and Methods

Extracted human teeth samples

Extracted teeth harvested as waste tissue were selected for ex-vivo imaging. No data that could identify patients were recorded and therefore was Institutional Review Board exempt. Teeth were stored in an isotonic saline solution containing 0.1% of sodium azide as an antimicrobial agent. Before the MRI experiments, water on the surface of the teeth was removed by blotting with paper towels and teeth were then wrapped with Teflon tape to reduce evaporation of water and isolate the tissue from equipment. A maxillary left second molar and a mandibular right second molar were chosen to test the feasibility of 31P MRI to access their overall anatomy and mineral content. In order to further test whether 31P MRI can detect mineral loss, two teeth with carious defects were selected: a mandibular right first premolar with buccal pit lesion and distolingual lesion in the crown; a maxillary left canine with restoration at the mesiolingual surface.

MR hardware and pulse sequences

MRI was performed on a 9.4T MR system (Agilent-Varian) with a home-built double resonance (31P and 1H) probe. The phosphorus RF coil consisted of two parallel copper loops of 1.5 cm in diameter at 1 cm distance. The proton RF coil was a copper single loop surface coil with 1.5 cm in diameter positioned in between the phosphate coil loops and oriented perpendicularly to them. The RF hardware allowed minimum “dead” times between excitation and acquisition and was 2 μs for the 1H frequency and 3 μs for the 31P frequency.

The SWIFT pulse sequence35,36 consists of a series of excitation RF pulses and simultaneous data acquisition (sampled in the gaps) in the presence of a readout gradient (Fig. 7). For the excitation pulse, an amplitude- and frequency-modulated hyperbolic secant based (HS2) pulse was used37,38,39. The phases of sequentially excited signals were unscrambled by correlation with the pulse function in the frequency domain. The ZTE sequence40,41 comprised of a short hard RF pulse with the readout gradient already on, followed by the acquisition (Fig. 7). Both sequences used small incremental changes of gradients between projections. The images were reconstructed from the acquired data using a gridding algorithm.

Figure 7
figure 7

Schematic representation of SWIFT and ZTE pulse sequences with saturation pulses applied at the proton frequency.

For SWIFT, the excitation pulse is divided into segments, each switching RF power on and off for signal acquisition (yellow colored). For both pulse sequences, the gradients were set to the required direction and amplitude. They remained constant until adjusted for the next repetition. The saturation pulse train comprises of 129 blocks of 10 ms each with a hard pulse of 400 μs width with a delay of 9.6 ms in between.

MRI experiments

Proton SWIFT images were acquired with an excitation bandwidth of 125 kHz, 256 gaps for sampling, an oversampling factor of 4 and 15° flip angle (FA). The field of view (FOV) was 3 × 3 × 3 cm. In total 32,000 radial spokes were acquired with a repetition time (TR) of 2.5 ms which includes a 2 ms total pulse length. The total acquisition time (TA) was 100 seconds. Images were reconstructed to a matrix of 256 × 256 × 256 pixels. Phosphorus SWIFT and ZTE images were both acquired with an excitation bandwidth of 62.5 kHz, 64 gaps for sampling, FA of 3.7°, oversampling factor of 4, TR of 200 ms, FOV of 3 × 3 × 3 cm3, TA of about 100 s for a low resolution (512 spokes) or 14 minutes for a higher resolution image (4,096 spokes) and receiver duty cycle (drec) of 0.5 in all the experiments. Almost all other parameters are similar, except for the short hard pulse excitation (5 μs length) applied in ZTE. Images were reconstructed to a matrix of 64 × 64 × 64 pixels. The global T1 and T2* relaxation times of the 31P spins were estimated (for the whole tooth) by inversion recovery and measuring line widths, respectively. Two regions of interests (ROIs) localized on dentin and enamel were manually drawn on the cross-sectional slices of the 31P images, to compare their difference in SNR. The SNR is evaluated by calculating the average signal divided by the standard deviation of the background signal.

Nuclear Overhauser effect enhanced 31P MR imaging

For the 1H-31P NOE enhanced experiments, the radiofrequency saturation of proton spins was implemented in the steady-state imaging scheme. The proton spins were saturated for 1.282 s during TR (1.482 s) by a hard pulse train (Fig. 7) of 129 hard pulses being 400 μs long with a pulse delay of 9.6 ms, by which full saturation of the proton magnetization was achieved42. This preparation pulse train for the NOE was the same for both ZTE- and SWIFT-images. The delay between the last 1H saturation pulse and the 31P excitation pulses was also the same and equal to 3 ms. To reach steady state for the NOE we applied 64 dummy scans in front of the MR acquisition. The saturation pulses were turned off for the non-NOE enhanced experiment, but the TR remained unchanged. For the estimation of the extent of the NOE the TA for 31P MRI both with and without NOE was about 48 minutes.

Solid-State NMR

To quantify the NOE build-up and to identify the source of the enhancement, a series of solid-state NMR spectroscopy experiments were performed. Dentin and enamel were separated and crushed into powder. Single pulse 1H NMR spectra were recorded on a Varian VNMRS 20 T solid-state NMR spectrometer using a 1.6 mm probe head under MAS at 35 kHz with a pulse length of 2.9 μs and relaxation delay of 5 seconds. 31P single pulse excitation and NOE experiments were performed on a 9.4T solid-state NMR system (Agilent-Varian), with a 3.2 mm rotor and a H-X-Y triple resonance probe head using a relaxation delay of 750 s at 10 kHz spinning rate. The 31P excitation pulse length was 5.5 μs. The 1H nuclei were saturated by a train of 1 ms soft pulses (ν1 = 450 Hz) separated by a delay of 1 ms, with a total saturation time ranging from 50 to 500 seconds. 1H-31P CP spectra at different contact times (100 μs − 15 ms) were recorded for dentin and enamel at 9.4T with a recycle delay of 10 s, an 1H excitation pulse length of 5.4 μs and 10 kHz spinning.

Additional Information

How to cite this article: Sun, Y. et al. Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement. Sci. Rep. 6, 30756; doi: 10.1038/srep30756 (2016).