Abstract
The discrete regenerative fuel cell is being developed as a residential power control that synchronizes with a renewables load which fluctuates significantly with the time and weather. The power of proton exchange membrane fuel cells can be scaled-up adjustably to meet the residential power demand. As a result, scale-ups from a basic unit cell with a 25 cm2 active area create a serpentine flow-field on an active area of 100 cm2 and take into account the excessive current and the remaining power obtained by stacking single cells. Operating a fuel cell utilising oxygen produced by the electrolyser instead of air improves the electrochemical reaction and the water balance. Furthermore, the performance test results with oxygen instead of air show almost no hysteresis, which results in the very stable operation of the proton exchange membrane fuel cell as well as the sustainable cycle of water by hydrogen and oxygen mediums.
Similar content being viewed by others
Introduction
Proton exchange membrane (PEM) fuel cells were first employed in the Gemini space programme1. In the 1970s, the development of Nafion® led to the large-scale use of this membrane in fuel cells2,3,4. The use of direct fuels, particularly hydrogen (H2), is one of several possible long-term approaches to the improvement of energy efficiency, energy sustainability, energy security, greenhouse gas reduction and global environmental conservation5,6,7,8. The PEM fuel cell is a fuel cell technology dedicated to delivering electric loads that are used irregularly and that exhibit high transient dynamics and frequent start and stop operations. Nevertheless, the main disadvantages of fuel cells are derived from the cells' erratic behaviour due to the high sensitivity of the stack state.
The primary motivation for developing a DRFC system linked with PV arrays was to create a platform for examining the stand-alone load-regulating characteristics in a controlled environment6,9,10. The dynamic behaviour of fuel cells is an integral part of the overall stability and performance of power systems. Moreover, many applications require dynamic transient responses that are faster than those exhibited by fuel cell systems11. This discrepancy has significant implications on stack performance due to temporal oxidant starvation caused by poor air flow dynamics, which thereby leads to low efficiency12 and a low lifetime as a result of cathode surface area loss13.
In this study, we characterised the hysteresis effects of a scaled-up PEM fuel cell for dynamic operation applications in a discrete regenerative fuel cell (DRFC) system with H2 and oxygen (O2). An optimisation process for serial and parallel scale-ups of PEM fuel cells was developed. Detailed data regarding the effects of hysteresis on the polarisation and power density of a serial scaled-up stack and a parallel scaled-up single cell and on the H2/air and H2/O2 reactants are presented. Operating a fuel cell utilising O2 produced by an electrolyser instead of air improves the electrochemical reaction and the water balance. Furthermore, the performance test results with O2 instead of air show almost no hysteresis, which results in the very stable operation of fuel cells as well as the sustainable cycling of water by H2 and O2 media. The results of this study can help us advance the hybrid O2-DRFC system linked with photovoltaic (PV) arrays and supercapacitors for developing a sustainable smart grid.
Results
To evaluate the performance and hysteresis of PEM fuel cells, we fabricated a basic unit cell, a serial scaled-up 4-cell stack and a parallel scaled-up single cell (Supplementary Fig. S1a) which featured novel serpentine flow channels combined with sub-channels and by-passes (Supplementary Fig. S1b and Table S1)14,15,16,17,18. The properties of a membrane electrode assembly (MEA), which is composed of two gas diffusion layers (GDLs), a membrane and two electrodes, are presented in Supplementary Table S215. The fuel cell performance was evaluated by the polarisation curve measured while adjusting the pressure, temperature, humidity and flow rate of the reacting gas using the test equipment (Supplementary Fig. S2 and Supplementary Table S3). We tested the polarisation and power density of the basic unit cell, the serial scaled-up 4-cell stack and the parallel scaled-up single cell utilising air and O2 as an oxidiser over 10 cycles while the load currents were controlled according to predefined schedules (Supplementary Fig. S3). Although the polarisation and power density curves with air and O2 as an oxidiser over 10 cycles were slightly different, such reproducible results were attributed to the change in the membrane conductivity, which caused the water content to move towards a higher current density zone19,20 (Supplementary Fig. S4). Detailed data regarding the hysteresis loop areas for the polarisation and power density of the basic unit cell, the serial scaled-up 4-cell stack and the parallel scaled-up single cell utilising air and O2 over 10 cycles are presented (Supplementary Table S4).
The hysteresis of polarisation curves can be observed during the repetitive increase and decrease in input current. The lower curves of hysteresis loops are created as the input current increases and the upper curves are created as the input current decreases. These phenomena are related to the flooding and drying of the fuel cell, respectively. If flooding occurs on the cathode side, then operation at a higher current would only make the situation worse because additional water would be produced (Fig. 1a). The polarisation curve recorded under a decreasing current would show a lower voltage at high currents than the polarisation curve recorded under an increasing current14. The polarisation and power density curves for a basic unit cell exhibit varying degrees of hysteresis; notably, the degrees of hysteresis with H2/O2 are lower than those with H2/air (Fig. 1b). We arrange the data of the hysteresis loop areas over 10 cycles with mean and standard error of the mean (s.e.m.). The dynamic stability is quantitatively explained by the hysteresis loop areas over 10 cycles with H2/air (polarisation curve: 0.4330 ± 0.0082 (mean ± s.e.m.); power density curve: 0.2652 ± 0.0051) and H2/O2 (polarisation curve: 0.1510 ± 0.0014 (mean ± s.e.m.); power density curve: 0.0703 ± 0.0014). These results indicate that the cathode flooding with H2/air increases the O2 mass transfer resistance in the electrode and the degrees of hysteresis in the polarisation and power density with H2/air become worse than those with H2/O2. In case of air, O2 is transported across the cathode GDL by a combination of pressure-driven convection through the porous GDL and concentration-driven diffusion, while N2 is transported in the opposite direction across the cathode GDL by a concentration-driven diffusion (Fig. 1c). Because the vapour in the cathode gas flow channel is saturated with water vapour, additional water produced at the cathode must be immediately condensed.
Fuel cell stacks consist of single cells connected in series or in parallel depending on the voltage and current requirements for specific applications21. These single cells experience some loss of efficiency and power density because of the scale-up in the area of the electrodes and the increased number of cells in the stack. These maldistribution problems could be reduced if the manifold of a parallel gas distribution system was optimised to homogenise the gas distribution within the stack22. Recently, the convection-enhanced serpentine flow-field design has been confirmed to exhibit a better water-handling ability than the conventional design15,16,17 and the cathode flow-field design for a single serpentine PEM fuel cell has promoted strong convection flows to enhance O2 transport and water removal23.To optimise the scale-up of the basic unit cell over a 25 cm2 active area, fuel cells with a total active area of 100 cm2 scaled up in series and in parallel were experimentally studied (Fig. 2 and Supplementary Fig. S1a).
The power density of the serial scaled-up stack was slightly higher than that of the basic unit cell with reactants of H2/air (Fig. 2a); this discrepancy was caused by the optimisation of the water management conditions near the higher current density zone because the stack was sufficiently cooled after exposure to electrochemical reaction heat. Therefore, the serial scale-up achieved by stacking single cells requires the careful design of a cooling system to improve the performances of the fuel cell stack. In this study, maximum cell voltage of the serial scaled-up stack was approximately four times higher than that of the basic unit cell; therefore, we could safely stack the single cells despite the complexities of the interconnected system. The hysteresis loop areas over 10 cycles were quantitatively evaluated for the serial scaled-up stack design with reactants of H2/air (polarisation curve: 2.2097 ± 0.0228 (mean ± s.e.m.); power density curve: 0.3661 ± 0.0048).
The power density of the parallel scaled-up single cell was higher than that of the basic unit cell with reactants of H2/air (Fig. 2b). The main reason for this discrepancy is that the removal of the product, liquid water, becomes more difficult in larger systems; however, a high water vapour pressure in the reactant flow causes an increase in the overpotential, especially at the cathode24. These maldistribution problems can be reduced if the manifold of a parallel gas distribution system is optimised to homogenise the gas distribution. The maximum cell currents of the parallel scaled-up single cell and the basic unit cell were limited to 120 A and 30 A, respectively. Therefore, parallel scaled-up single cells should be limited under heavy current loads for safety and compactness in DRFC systems. The hysteresis loop areas over 10 cycles were quantitatively evaluated using the serial scaled-up stack with reactants of H2/air (polarisation curve: 0.2751 ± 0.0114 (mean ± s.e.m.); power density curve: 0.0335 ± 0.0010).
Scaled-up PEM fuel cells in air-DRFC (Fig. 3a) and O2-DRFC (Fig. 3b) configurations have been developed25. O2-DRFC systems exhibit higher performance and efficiency, do not require oxidant compressors and can operate in a completely closed cycle with little maintenance but require approximately 50% more tank space to store O2, which can be a safety hazard due to its high flammability. The operation of a fuel cell with O2 instead of air using a platinum catalyst supported on carbon yields a 17% improvement in fuel cell efficiency9. Consequently, O2-DRFC systems are currently preferred in cases in which compressed O2 storage does not pose a significant safety hazard.
We present the experimental results obtained in this study by comparing the polarisation and the power density curves between the reactants of H2/O2 and H2/air in the serial scaled-up 4-cell stack and the parallel scaled-up single cell, respectively (Fig. 3c, d). In the serial scaled-up 4-cell stack, the areas of the hysteresis loops over 10 cycles were quantitatively evaluated with H2/O2 (polarisation curve: 0.7520 ± 0.0834 (mean ± s.e.m.); power density curve: 0.0906 ± 0.0058). The maximum power densities with the H2/air and H2/O2 reactants were 0.664 W/cm2 and 0.838 W/cm2, respectively; therefore, the reactants of H2/O2 exhibited 26.2% higher power density. In the parallel scaled-up single cell, the areas of the hysteresis loops over 10 cycles were quantitatively evaluated with H2/O2 (polarisation curve: 0.1505 ± 0.0131 (mean ± s.e.m.); power density curve: 0.0167 ± 0.0018). The maximum power densities with the H2/air and H2/O2 reactants were 0.722 W/cm2 and 0.836 W/cm2, respectively; therefore, the reactants of H2/O2 exhibited 15.8% higher power density. The dynamic stability and performance of the fuel cells were confirmed to be higher with H2/O2 than with H2/air in both the serial scaled-up 4-cell stack and the parallel scaled-up single cell.
Discussion
The PEM fuel cells utilised in the experiments featured serpentine flow channels combined with sub-channels and by-passes. Previous studies have shown that the implementation of a novel flow-field design improves not only the flow consistency of the inner reaction gas and the liquid water behaviour but also the current density in the ohmic resistance loss region and mass transport loss region. Compared to the conventional flow-field design, the novel flow-field design features a much smaller area surrounded by the hysteresis curve because of a varying electric load, but no difference in the hysteresis curve is observed in the high-current-density region. To demonstrate the dynamic behaviours of the basic unit cell with the novel flow-field design, which features added sub-channels and by-passes with respect to the conventional flow-field design, we investigated the performance of the polarisation and power density curves of cells with H2/air and H2/O2 reactants.
The hysteresis effects of PEM fuel cells were investigated under serial and parallel scale-up designs by increasing the active area, stacking single cells and enhancing the power generated by utilising H2/O2 instead of air as a reactant. Thus, we could observe the hysteresis effects created in the fuel cell systems as the load was fluctuating. When the membrane of a PEM fuel cell is fully hydrated, the water is balanced within the MEA26. A larger void volume in the diffusion layer is most likely to be occupied by liquid water when using pure O2. The fuel cell can run at a higher current density with a small degree of gas diffusion if the generated water is carried out of the fuel cell by the gas. Thus, the hysteresis in the polarisation curves of O2-DRFC systems is reduced, allowing for the sustainable cycling of water.
Methods
Hysteresis characterisation
PEM fuel cell performance was evaluated by polarisation curves measured while adjusting the pressure, temperature, humidity, flow rate and reacting gas using fuel cell test equipment built at INJE University. Experiments were carried out using the FCTESTNET (Fuel Cells Testing & Standardisation NETwork) performance test procedure27, which was originally developed under the Research & Training Network (RTN). The FCTESTNET performance test procedure is a method used to evaluate the activation loss region and the ohmic resistance loss region of fuel cells. In the performance tests, the load current was controlled to minimise physical damage to the MEA and to maintain a stable electrical load. The detailed test procedures are as follows: for the experiments with the 25 cm2 basic unit cell and the 25 cm2 serial scaled-up stack, the cell current was increased from 0 A to 30 A in increments of 1 A and then decreased to 0 A in decrements of 1 A for 300 s, whereas for the experiments with the 100 cm2 parallel scaled-up stack, the cell current was increased from 0 A to 120 A in increments of 5 A and then decreased to 0 A in decrements of 5 A for 500 s.
To analyse the hysteresis characteristics quantitatively, a mathematical integration programme that calculates the area inside the hysteresis loop in the polarisation and power density curves was developed using Matlab®. In the programme, the areas between upper and lower curves in a hysteresis loop were calculated by taking the integral of the polynomial equation of each curve from the lower limit to the upper limit of the current variations on the x-axis. Then, the area covered by the lower curve was subtracted from the area covered by the upper curve to obtain the hysteresis loop area.
Preparation of fuel cell
Fuel in the form of H2 gas is fed into the anode side of the PEM fuel cell. The oxidant in a fuel cell is O2, either in air or as a pure gas, which enters the fuel cell through the cathode inlet. The reactant gases H2 and O2 flow through channels machined into graphite plates and migrate through GDLs to the catalyst surface on their respective sides of the MEA. Aided by the noble metal catalyst in the anode, hydrogen is oxidised to form protons and electrons. To evaluate the performance of PEM fuel cells, we fabricated a basic unit cell with 5 passes and 4 turns on an active area of 5 × 5 cm2, a serial scaled-up 4-cell stack with 5 passes and 4 turns on an active area of 5 × 5 cm2 and a parallel scaled-up single cell with 7 passes and 4 turns on an active area of 12.5 × 8 cm2.
Fuel cell testing
The bipolar plates (BPs) of the anode and the cathode were produced in the same semi-counter flow format; that is, the inlet and the outlet of hydrogen were at the top left and the bottom right, respectively, while the inlet and the outlet of oxygen or air were at the top right and the bottom left, respectively. A unique feature of PEM fuel cells compared with other types of fuel cells is that the former feature a solid proton-conducting electrolyte. The MEA is the ‘heart’ of the PEM fuel cell. In this study, a W.L. Gore & Associates PRIMEA® Series 57 MEA (anode: Pt catalyst 0.4 mg/cm2, cathode: Pt catalyst 0.4 mg/cm2) was used and sandwiched between anode and cathode SIGRACET® GDLs, which have a porous structure28. The MEA has a membrane and two electrodes composed of highly dispersed carbon-supported platinum catalysts. The PEM fuel cell performance was evaluated by measuring polarisation curves while adjusting the pressure, temperature, humidity, flow rate and reacting gas using fuel cell test equipment built at INJE University. Because the PEM fuel cell performance depends greatly on the operating conditions, the test equipment controlled the operation of the PEM fuel cells carefully and continuously. The test equipment consists of an electronic load, a flow controller, a temperature controller, a relative humidity controller and a DEWETRON DEWE-30-16 data acquisition system.
The initial performance of the fuel cells was greatly affected by the humidification of the MEA, the electrical load and the abundant supply of the reaction gas. Therefore, sufficient humidification was induced for 30 min to hydrate the dried MEA prior to measuring cell performance. The experiment was carried out using the FCTESTNET performance test procedure. The FCTESTNET performance test procedure is a method used to evaluate the activation loss region and the ohmic resistance loss region of fuel cells. In the performance test, the load current was controlled to minimise physical damage to the MEA and to maintain a stable electrical load. The results of each test procedure were confirmed by supplemental literature and experiments15,16,17.
References
Cohen, R. Summary of Analysis for Selecting the Power Source for the Gemini Project. NASA-MSC (Jan 20, 2014) Available online at history.nasa.gov/SP-4002/p1b.htm, Date of access: 18/02/2014.
Ball, P. Smart materials: Off and on reflection. Nature 391, 232; 10.1038/34547 (1998).
Steele, B. C. H. & Heinzel A. Materials for fuel-cell technologies. Nature 414, 345; 10.1038/35104620 (2001).
Bose, S. et al. Polymer membranes for high temperature proton exchange membrane fuel cell: Recent advances and challenges. Prog. Polym. Sci. 36, 813; 10.1016/j.progpolymsci.2011.01.003 (2011).
Haile, S. M., Boysen, D. A., Chisholm, C. R. I. & Merle, R. B. Solid acids as fuel cell. Nature 410, 910; 10.1038/35073536 (2001).
Patil, M. B., Bhagat, S. L., Sapkal, R. S. & Sapkal, V. S. A review on the fuel cells development. Sci. Revs. Chem. Commun. 1, 25–41 (Oct. 14, 2011). Available online at http://www.sadgurupublications.com/ContentPaper/2011/4_108_1(1)2011.pdf, Date of access: 18/02/2014.
Kim, H.-M. Green strategy: South Korean energy plan is unrealistic. Nature 477, 280; 10.1038/477280b (2011).
Debe, M. K. Electrocatalyst approaches and challenges for automotive fuel cells. Nature 486, 43; 10.1038/nature11115 (2012).
Mitlitsky, F., Myers, B. & Weisberg, A. H. Regenerative fuel cell systems. Energ. Fuel. 12, 56; 10.1021/ef970151w (1998).
Li, X., Xiao, Y., Shao, Z. & Yi, B. Mass minimization of a discrete regenerative fuel cell (RFC) system for on-board energy storage. J. Power Sources 193, 342; 10.1016/j.jpowsour.2010.02.045 (2009).
Talj, R. et al. Parameter analysis of PEM fuel cell hysteresis effects for transient load use. Eur. Phys. J.-Appl. Phys. 54, 23410; 10.1051/epjap/2011100266 (2011).
Taniguchi, A., Akita, T., Yasuda, K. & Miyazaki, Y. Analysis of electrocatalyst degradation in PEMFC caused by cell reversal during fuel starvation. J. Power Sources 130, 42; 10.1016/j.jpowsour.2003.12.035 (2004).
Wahdame, B. et al. Comparison between two PEM fuel cell durability tests performed at constant current and under solicitations linked to transport mission profile. Int. J. Hydrog. Energ. 32, 4523; 10.1016/j.ijhydene.2007.03.013 (2007).
Choi, K.-S., Kim, H.-M. & Moon, S.-M. Numerical studies on the geometrical characterization of serpentine flow-field for efficient PEMFC. Int. J. Hydrog. Energ. 36, 1613; 10.1016/j.ijhydene.2010.10.073 (2011).
Choi, K.-S., Kim, H.-M. & Moon, S.-M. An experimental study on the enhancement of the water balance, electrochemical reaction and power density of the polymer electrolyte fuel cell by under-rib convection. Electrochem. Commun. 13, 1387; 10.1016/j.elecom.2011.08.015 (2011).
Choi, K.-S., Kim, B.-G., Park, K. & Kim, H.-M. Current advances in polymer electrolyte fuel cells based on the promotional role of under-rib convection. Fuel Cells 12, 908; 10.1002/fuce.201200035 (2012).
Choi, K.-S., Kim, B.-G., Park, K. & Kim, H.-M. Flow control of under-rib convection enhancing the performance of proton exchange membrane fuel cell. Comput. Fluids 69, 81; 10.1016/j.elecom.2011.08.015 (2012).
Lee, B., Park, K. & Kim, H.-M. Numerical optimization of flow field pattern by mass transfer and electrochemical reaction characteristics in proton exchange membrane fuel cells. Int. J. Electrochem. Sci. 8, 219–234 (2013). Available online at www.electrochemsci.org/papers/vol8/80100219.pdf, Date of access: 18/02/2014.
Hou, J. et al. Reversible performance loss induced by sequential failed cold start of PEM fuel cells. Int. J. Hydrog. Energ. 36, 12444; 10.1016/j.ijhydene.2011.06.100 (2011).
Benziger, J., Kimball, E., Mejia-Ariza, R. & Kevrekidis, I. Oxygen mass transport limitations at the cathode of polymer electrolyte membrane fuel cells. AIChE J. 57, 2505; 10.1002/aic.12455 (2011).
Zawodzinski, T. A. et al. Water-uptake by and transport through Nafion® 117 membranes. J. Electrochem. Soc. 140, 1041; 10.1149/1.2056194 (1993).
Costamagma, P. & Srinivasan, S. Quantum jumps in the PEMFC science and technology from the 1960s to the year 2000 Part I. Fundamental scientific aspects. J. Power Sources 102, 242; 10.1016/S0378-7753(01)00807-2 (2001).
Wilkinson, D. P., Voss, H. H. & Prater, K. Water management and stack design for solid polymer fuel cells. J. Power Sources 49, 117; 10.1016/0378-7753(93)01803-P (1994).
Hussaini, I. S. & Wang, C. Y. Transients of water distribution and transport in PEFCs. J. Electrochem. Soc. 156, B1394; 10.1149/1.3236646 (2009).
Anderson, E. Development of reversible fuel cell systems at Proton Energy. Reversible Fuel Cells Workshop U.S. DOE 19th, 27–57 (2011). Available online at http://www1.eere.energy.gov/hydrogenandfuelcells/pdfs/rev_fc_wkshp_report.pdf, Date of access: 18/02/2014.
Ma, W. et al. Cross-linked aromatic cationic polymer electrolytes with enhanced stability for high temperature fuel cell applications. Energ. Environ. Sci. 5, 7617; 10.1039/C2EE21521G (2012).
Malkow, T. et al. PEFC power stack performance testing procedure Measuring voltage and power as function of current density Polarisation curve test method Test Module PEFC ST 5–3; 10.2790/18880 (Publications Office of the European Union, © European Union, 30 April, 2010). Available online at http://iet.jrc.ec.europa.eu/fuel-cells/sites/fuel-cells/files/files/documents/Long_Term_Durability_Stedy_State_TestProcedure_ST_5-6.pdf, Date of access: 18/02/2014.
Jeon, D. H., Greenway, S., Shimpalee, S. & Van Zee, J. W. The effect of serpentine flow-field designs on PEM fuel cell performance. Int. J. Hydrog. Energ. 33, 1052; 10.1016/j.ijhydene.2007.11.015 (2008).
Acknowledgements
We thank N. Paik for sustaining the hydrogen fuel cell research. This work was partly supported by a National Research Foundation of Korea (NRF) grant funded by the Korean government (MEST) (No. 2009-0080496) and partly supported by the New & Renewable Energy of the Korea Institute of Energy technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No. 2012T100100660).
Author information
Authors and Affiliations
Contributions
Experiments were designed by K.-S.C. and H.-M.K., fieldwork was performed by K.P. and J.L., statistical analyses were performed by K.P. and H.-M.K., supplementary methods and analysis were performed by G.H., K.-S.C. and H.-M.K. and writing was performed by K.-S.C. and H.-M.K. with the input from K.P., J.L. and G.H. All authors discussed the results and commented on the manuscript.
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Electronic supplementary material
Supplementary Information
Supplementary Information
Rights and permissions
This work is licensed under a Creative Commons Attribution 3.0 Unported License. The images in this article are included in the article's Creative Commons license, unless indicated otherwise in the image credit; if the image is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the image. To view a copy of this license, visit http://creativecommons.org/licenses/by/3.0/
About this article
Cite this article
Park, K., Lee, J., Kim, HM. et al. Discrete regenerative fuel cell reduces hysteresis for sustainable cycling of water. Sci Rep 4, 4592 (2014). https://doi.org/10.1038/srep04592