Introduction

MEG via impact ionization, enhanced by discrete energy levels due to quantum confinement in semiconductor quantum dots (QDs), was propsed by Nozik in 20011. The process was experimentally observed by Klimov et al. in 2004 using pump-probe spectroscopy2. Since then many researchers have investigated MEG in different QD materials using similar techniques, however, the yields have been found to be modest and the initial estimations of very high yields were attributed to the signal distortion due to the photocharging of the quantum dots and the surface defects3. Though these controversies have been rectified in recent experiments, the reported MEG yields still diverge significantly4,5. Previous works6,7 have shown that the photo-luminescence intensity of QDs is not proportional to the number of excitons in the system and proper scaling factors have to be used to quantify MEG yields in such experiments8,9. As far as we know, all the MEG studies using pump-probe spectroscopy have so far assumed that the observed signal scales linearly with the number of excitons2,4,10,11,12. The assumption can be related to the simple state-filling argumentation where the enhanced transmission of the probe beam, also known as the bleach signal, when the probe wavelength is tuned to energies above the band-gap, is due to to the gradual filling of the low lying conduction band electron states that correspond to the band-edge transitions. This qualitative assumption does not consider any refinement due to the confinement-related correlation effects in QDs and might be insufficient for quantitative analyses. In this article we describe a modified analysis of the MEG yield based on transient absorption (pump-probe) measurements. We derive formulas to determine the calibration constants for the transient absorption measurements and use them to calculate MEG yield in lead chalcogenide nanocrystals. Our calculations show that the photobleach signal due to a biexciton in nano-crystals is not always equal to twice the signal from a single exciton. Hence, proper scaling factors need to be determined for accurate calculation of the MEG yield. Though the methodology is general and applies to all the techniques that use time resolved spectroscopy with sub-picosecond time resolution, we focus on the time resolved bleach signal measured in our experiments.

The physical processes that lead to the relaxation of bi- or multi-excitons are different to that of the single excitons; Auger recombination dominates in the former while spontaneous emission plays the major role in the later. The time scales of Auger recombination –few tens of picoseconds in case of samples investigated here – is distinctly different from that of the spontaneous emission –tens of nanoseconds. Consequently, the signatures of the single and multi-excitons can be conveniently distinguished in a time-resolved spectroscopy measurement as demonstrated below2,13.

Figure 1(a) shows the bleach signal of the probe pulse (probe photon energy, Eprobe ≈ 1.18 eV) in PbS quantum dot (Eg ≈ 1.07 eV) under different pump intensities (excitation photon energy, Eex ≈ 1.6 eV). At low pump intensity, when the probability of sequential absorption of two photons and hence the population of multi-excitons is negligible, the bleach signal (red line) does not show appreciable decay after the action of the pump. While at high pump intensities, when more than one exciton are created in some QDs, a fast decay within few tens of picoseconds is observed (blue line). The fast decay in the signal is due to the loss of the exciton population by Auger recombination. When the photon energy of the pump pulse is increased to values higher than 3Eg the fast decay of the signal persists even for pump fluence for which the absorption of two photons can be safely neglected. Figure 1(b) compares the bleach signal of the probe pulse when the samples are excited with pump-pulses with two different photon energies: the first with photon energy 1.6 eV where Eex < 2Eg (red curve) and the second with photon energy 3.76 eV where Eex > 3Eg (green curve). The red curve in the figure has been multiplied by 0.82 to match the signal at long time delay with the green curve. The average number of photons absorbed per quantum dots (calculated using Equ.(6)) in both excitations is less than 0.065. The soft modulations seen in the data points in Figure 1(b) are due to the slow oscillations in the laser amplification cavity. The prominent fast decay in the green curve is explained by the loss of multi-exciton population by Auger recombination as seen in the blue curve in Figure 1(a); here multi-exciton is generated by MEG. Note that we use the term MEG explicitly to the process whereby the multi-excitons are generated by the splitting of a high energy single exciton to two or more low energy excitons rather than the sequential generation of excitons by the absorption of more than one photon. Though the amplitudes of the decay signals are the signatures of multi-excitons they are only a qualitative indication of MEG. These amplitudes need to be scaled with appropriate calibration factors to get a quantitative estimate of the number of multi-excitons generated via MEG.

Figure 1
figure 1

(a) Transient absorption signal from PbS QDs with band gap energy Eg ≈ 1.07 eV probed at Eprobe ≈ 1.18 eV when excited with laser pulses with photon energies Eex ≈ 1.6 eV. The signal at high pump intensity (blue curve, 4 μJ energy per pulse) shows fast initial decay, which is due to the Auger recombination of the excitons when more than one exciton is created per QD. As the pump intensity is lowered (red curve, 1 μJ energy per pulse), the probability that a QD absorbs more than one photon becomes negligible, consequently the fast decay vanishes. (b) Transient absorption signal when excited with high energy photons, Eex ≈ 3.76 eV, (green curve) compared with the signal with low energy photon excitation.

The amplitudes of the signal due to different exciton numbers – bi, tri, etc. – in Figure 1 are usually found by fitting the data with multiple exponentials13; higher multi-excitons decay faster than the lower ones. In this work, we only consider the cases where the contribution to the signal from tri- and higher excitons can be neglected, hence the signal can be safely separated into two components, one lasting few tens of picosecond associated with the biexciton population and the other lasting few tens of nano-seconds associated with the single exciton population. In these cases it is not necessary to use curve fitting to find the single and the biexciton contributions to the signal, one can use the signal shortly after the pump-excitation and the signal after few hundred picoseconds to estimate the different contributions2,10. Quantifying the multi-exciton populations from the amplitudes, however, is non-trivial as the impact of complex electronic structure14,15, e.g. the interplay between the Coulomb and the exchange interactions16,17,18, on the dynamics and the amplitudes cannot be predicted per se. Thus a proper scaling factor is necessary to compute the multi-exciton population. In the following we describe how the scaling factors can be calculated from the time-resolved experiments themselves.

Results

Computational methodology

The probe signal immediately after the pump excitation with photon energies less than the MEG threshold can be written as:

where S(t) denotes the time varying signal, t denotes the delay time with the subscript indicating the delay time between the pump and the probe pulse, ai is the signal contribution due to the ith exciton and P(i) denotes the probability of ith exciton being populated by the absorption of i photons. As usual, we use Poisson distribution:

where ρ is the average number of photons absorbed per quantum dot. The probe signal is given by .

For small values of ρ (ρ < 0.25), the higher order terms can be neglected in our measurements. The probability of exciting tri- and higher excitons is less than 0.0022 when ρ < 0.25, which is insignificant compared to the probability of exciting single and bi-excitons. Moreover, the increase in the short time signal, S(t0), shown in Figures 2 and 4 is slower than a linear rise. This clearly shows that the contribution to the signal from a higher n-th exciton (n>2) is less than n times the signal from a single exciton. Note, that S(t0) increases linearly with the intensity if the signal from the n-th exciton is n times the signal from a single exciton for all n.

Figure 2
figure 2

Transient absorption signal of PbSe nanorods at different excitation intensities: blue points shortly after the pump excitation and red points after a long time delay.

Red line is the fit to the long time signal using Equ.(6). Upper axis is in the units of average excitation per QD.

Figure 3
figure 3

Time resolved probe signal for 1.6 eV (red curve) and 3.2 eV (green curve) pump-photon excitations.

The average excitation fluence is 5 × 109 photons cm−2 pulse−1. The band gap of the PbSe nanorods is about 1 eV. The green curve shows prominent fast initial decay even for lower average number of photons absorbed per quantum dot than for the red curve, which indicates MEG. The quantum yield of the MEG in this case is about 1.21.

Figure 4
figure 4

Bleach signal vs. intensity (photo-voltage from a linear detector) at two different delay times in PbS QDs.

The red points show the probe signal at long time, 800 ps after the pump excitation with various fluences. Red line is the fit to the data points using Equ.6. The blue points show the corresponding probe signal at short time, about 3 ps after the temporal overlap of the pump and the probe beams. Upper axis is in the units of average excitation per QD.

Neglecting the higher order terms, the signal can be written as:

where k = a2/a1.

The probe signal at long time delay, when all the bi-excitons have decayed to the single excitons, is S(tl) = a1 exp(−ρ)ΣI = 1 ρi/i!, which, when truncated after the second term, can be written as:

The relative strength of the biexciton contribution to the signal with respect to the single exciton contribution can be obtained from the ratio between the probe signal at the zero time delay and the long time delay:

where x = S(t0)/S(tl). k is sufficient to quantify the MEG yield in the experiments where tri- or higher exciton formation by MEG can be neglected. Otherwise the higher order terms have to be included in Equ.(3) and Equ.(4) to determine even the calibration factors for the higher excitons (see the supporting information for the derivations of the equations in detail).

The average number of photons absorbed per quantum dot, ρ, is related to the fluence: ρ = σabsI, where σabs is the absorption cross-section at the pump wavelength. Using this relation in Equ.(5) has drawbacks because σabs is not always known, specially when new systems are investigated and the fluence I can have large uncertainties unless one uses precisely calibrated detectors for specific wavelengths and accurately measures the focus spot size. To reduce the uncertainties we determine ρ by fitting the fluence dependent long time delay transient absorption signal S(I;tl) to the following relation (see the supporting information for the derivation):

where α is a constant, I0 is the reference fluence and ρ0 is the fitting parameter. This equation is particularly useful in experiments where the focus spot size of the pump beam is much bigger than the probe, like we are using here. When the probe focus is comparable to the pump, the bleach signal samples nano-particles that are excited with different intensities and the signals due to single and multi-excitons get averaged19. In this case a more generalized approach may be useful9.

Note that Equ.(6) uses the ratio of the fluences therefore any measurable quantity which is linearly related to the fluence can be used. In our experiments I represents the voltage response from a photo-detector. Using linear response from the photo-detector substantially reduces the uncertainties related to the determination of the fluence. In the following we use Equ.(5) and Equ.(6) to calculate the MEG yield in PbSe nanorods.

Calculations

The nanorods were prepared using the protocol described by Melinger et al11. Figure 2 shows the probe signal (λ = 1100 nm, Eprobe ≈ 1.13 eV) at short time delay, t < 15 ps (blue points) and at long time delay, t > 800 ps (red points), after the excitation with the pump pulse (λ = 775 nm, Eex ≈ 1.6Eg) for the different pump intensities. The x-axis in the figure is the voltage response from a photo-diode monitoring the pump pulses, which is linearly proportional to the intensity of the pump. The red line is the fit to the long time delay signal using Equ.(6), which gives ρ0(I0 = 0.005 V) = 0.024 ± 0.002; ρ for other intensities can be calculated using the relation ρ I.

We use the data point (boxed in Figure 2) with ρ = 0.226, S(t0) = 2.51 × 10−4 ± 1 × 10−6 and S(tl) = 2.08 × 10−4 ± 3 × 10−6 to determine k, the relative contribution to the probe signal from biexcitons. For ρ = 0.226, P(2) = 0.02 and P(3) = 0.0015, so that tri- and higher exciton contribution can be safely neglected while at the same time there is enough contribution from the biexcitons. Using Equ.(5) we get k = 3.1 ± 0.4; error propagation from the uncertainties in x, Δx = 0.02 and ρ, Δρ = 0.002, is used to compute the uncertainty in k. For other values of ρ, 0.25 > ρ > 0.1, we get 3.5 > k > 3.1, which is within the uncertainty range of k at ρ = 0.226. For ρ < 0.1 biexciton contribution is negligible while for ρ > 0.25 tri-exciton contribution cannot be neglected. Similar calculations done on PbS QDs using the data shown in Figure 4 give k = 1.9 ± 0.2. So the scaling factors are not the same for different nano-particles. Previous works have indicated that they can depend on the probe wavelength as well20.

Figure 3 compares the probe signal when the PbSe nanorods are excited with 3.2Eg (green curve; UV excitation) and 1.6Eg (red curve; NIR excitation) photons. ρ = 0.139 for the NIR excitation is calculated from the Figure 2 and the ρ = 0.094 for UV excitation is calculated using the relation S(tl) ρ for ρ < < 1. For ρ < 0.1 the probability of populating a bi-exciton is less than 0.005. We take this as the condition when the signal at long time delay is linearly proportional to ρ (see Equ.(4) and the supporting information for the details). The signals immediately and after long time delay following the UV excitation are S(t0) = (1.48 ± 0.06) × 10−4 and S(tl) = (0.95 ± 0.04) × 10−4, respectively. The average excitation fluence in this measurement is about 5 × 1010 photons cm−2 pulse−1. The average fluence is calculated from the power of the pump beam measured by a powermeter calibrated for UV photons. For k = 3.1 and ρ = 0.094 the expected signal Sex(t0) calculated using Equ.(5) if there was no MEG would be (1.04 ± 0.06) × 10−4. The rest of the signal, S(t0) − Sex(t0) = (0.44 ± 0.08) × 10−4, is due to the MEG. If η is the MEG yield, the fraction of the initially populated excitons that undergo MEG, then the total initial signal can be written as the sum of the signal from the bi-excitons, ηkSex(t0) and the single excitons, (1 − η)Sex(t0):

Using the values for S(t0), Sex(t0) and k in Equ.(7), we get η = 0.21 ± 0.05. The corresponding quantum yield of the exciton generation is ϕ = 1.21 ± 0.05.

Discussion

The MEG yield, η, we have obtained in the NRs is slightly less than the yield in QDs but within the error range4. Our results agree with some previous works, which show that Auger like processes in NRs can be suppressed as compared to QDs21. On the other hand, our results do not show significant enhancement in the MEG yield in NRs as observed recently11. However, these conflicting results are not directly comparable as the previous calculations11 implicitly assume k = 2, which leads to different yields even if the data are similar.

As far as we know all of the work on the quantification of the MEG yields based on the pump-probe measurements on QDs use k = 2. This value is based on the assumption that the exciton bleach signal is due to state filling of the exciton bands. In the case of PbS QDs, the lowest band can accomodate 8 excitons. According to the assumption, the signal S(t0) should scale linearly with intensity untill the lowest exciton band is completely filled with the excitons. However, even for modest intensities for which ρ < 1 the signal S(t0) shown in Figure 2 for the NRs and Figure 4 for the PbS QDs deviates from the linear relationship. This indicates the possibility of exciton-exciton correlation effects in nano-particles in strong confinement regime. Though these effects have not been the focus of current research, further studies of such effects might be important for the deeper understanding of MEG in nano-particles.

Recent studies argue that the observed MEG yields in QDs may not improve the efficiency of photo-voltaic cells as compared to conventional solid state devices22. Consequently, the current research trend has diverged into investigating nano-particles whose shape, size and composition are different from the idealized quantum dots. It has been observed that these modifications can dramatically alter the spectroscopic properties of the nano-particles21. In this context assuming k = 2 when quantifying the MEG yields cannot be justified. Moreover, the MEG yields determined by photoluminescence measurements9 that take into account the proper scaling factors differ from the yields obtained by the pump-probe techniques. Use of the proper scaling factors in the pump-probe measurements could provide valuable insight into the discrepancies.

To conclude, our experiments show only modest MEG yields in PbSe NRs. Using our methodology we found that the bleach signal due to a biexciton in nano-particles is not always twice the bleach signal from a single exciton. It is important to explicitly compute the proper scaling factors that relate the populations to the signal amplitudes for the accurate quantification of the MEG yields in different nano-particles. It is also important to follow such a methodology for meaningful comparison the MEG yields obtained by using different experimental techniques8,9,24,25.

Methods

Pump-probe spectroscopy

The schematic of the pump-probe setup is shown in Figure 1 of the Supplementary Information. The pulses (1.2 mJ pulse energy, 1 kHz repetition rate, center wavelength at 775 nm and pulse duration about 150 fs) generated from the amplified laser (CPA 2001) are split using a beam splitter to generate the pump as well as the probe pulse. The probe pulse in the infra-red region (λ > 1000 nm) are generated using a non-collinear optical parametric amplifier (NOPA). An analyzer is used to define the horizontal polarization of the pulses. The delay stage before the NOPA controls the time delay between the pump and the probe pulses. A 50 cm focal length concave mirror with a hole at the center is used to focus the probe pulses to the sample. The 775 nm pulses from the amplifier are used as the pump for the NIR pump (for the experiments done to measure the Auger decay without MEG). The 387 nm pulses from the second harmonic of the 775 nm pulses are used as the pump for the UV excitation to investigate the MEG process. The pump pulses are chopped at 500 Hz using a mechanical chopper. A Berek compensator is used to rotate the polarization of the pump beam and an analyzer is used to define the horizontal polarization. The intensity of the pump beam is controlled by the compensator/analyzer combination. The probe beam is polarized at the ‘magic angle’ with respect to the pump. The pump beam is focused into the sample using a lens with focal length 1 m. A little fraction of the pump beam is directed to the photo-dectector to monitor the intensity of the pump pulses. The pump diameter at the focus is about 0.7 mm and the probe diameter is about 0.4 mm. The optical density of the samples at the excitation wavelengths is kept below 0.3. As the absorption cross-sections at the different excitation wavelenghts are different, the signals need to be normalized by the concentration of the nano-crystals in the solution for the comparison. We have chosen to normalize them by the optical density at 450 nm. The samples are shaken during the measurements to avoid degradation due to photocharging. Typical error in the measurements is in the order of 10−7Δ OD. At such low error condition the signatures of photocharges can be seen as the pre-pump signal. We see such pre-pump signal in the cases with high pump fluence where the signal is in the order of 10−2Δ OD (shown in Figure 2 of the Supplementary Information). All the measurements used in the analysis are done with pump fluence where the signal is at least an order of magnitude smaller (10−3Δ OD). The signal level in our measurements for MEG is in the order of 10−5Δ OD, about three order of magnitude smaller than in the case when photocharging is discernible. No photocharging has been reported for the corresponding average number of excitons excited in the QDs. We probe above the band edge to avoid the artifacts due to ultrafast (sub-picosecond) de-population of the band edge by surface trapping. We also set S(t0) to 3 ps after the pump pulse to avoid the sub-picosecond de-population component in the dynamics.

Materials and synthesis

Lead oxide (> 99.9%), oleic acid (OA, >99%), selenium (99.5%, 100 mesh), trioctylphosphine (TOP, >90%), tris(diethylamino)phosphine (TPD, 97%) and bis(trimethylsilyl) sulfide (TMS) were purchased from Aldrich. Solvents used in the synthesis included 1-octadecene (ODE, 90%), toluene (anhydrous, 99.8%), hexane (95%), heptane (96.7%), acetone (HPLC, >99.8%), chloroform (>99.9%) and ethanol (99.7%). All chemicals were used as received.

The synthesis method for the quantum dots can be found elsewhere23. Briefly, 446 mg (2 mmol) lead PbO was dissolved in a mixture of 2 ml OA and 20 ml ODE then was heated to 90°C under N2 in a three necked flask. After PbO is completely decomposed to form colorless Pb oleate the solution further heated to various temperatures for QDs growth. 0.2 ml of TMS dissolved in 10 ml ODE was rapidly injected into the Pb oleate solution. The rapid injection of TMS solution into the reaction flask changed the color of the reaction mixture from colorless to deep brown. The reaction continued for 2 min. The solution in the flask was dissolved in 10 ml of toluene and was precipitated with methanol and acetone and then redispersed in non-polar solvent such as hexane and toluene for storage. To vary the size of the nano-particles, the injection temperature was changed. The TEM image of the QDs grown at 160°C are is shown in Figure 3 of the Supplementary Information.

The synthesis method for the nanorods can be found elsewhere11. Briefly, 4 mmol PbO and 10 mmol OA were mixed with ODE with a total weight of 16 g in a three-neck flask. The mixture was then purged with N2 and heated to 150°C to form colorless Pb oleate solution. Then 5.9 ml Se-TDP solution with 6 mmol Se was injected into Pb oleate solution containing 2 mmol PbO, 6 mmol OA and 31 mmol ODE at 130°C and allowed to react for 2 mins. The aliquot was rapidly cooled using ice bath. Heptane and ethanol were used to purify the NRs for at least twice and finally dissolved in hexane. The morphology of the obtained nanorods is shown in Figure 4 of the Supplementary Information.

Data analysis

Here we summarize the main steps for the analysis of the MEG yield developed in this article based on the pump-probe spectroscopy. Measurements are done first using NIR pump for various pump intensities. The long time signal, S(tl), is fitted with Equ.(6). The average number of excitons per quantum dot, ρ, is obtained from the fitting. The calibration constant, k, is calculated using Equ.(5) for ρ ≈ 0.23. Once k is determined, a measurement is done using UV pump for very low pump intensity. For the measurement, the sample is diluted such that the optical density of the sample at the pump wavelength is less than 0.25. The long time signal from this measurement is normalized by the optical density of the sample at 450 nm. Alternatively, one can also normalize the signal by the number of times the sample has been diluted. The normalized signal is compared with similarly normalized signal from the previous measurements done with the NIR pump. The ρ for the UV excitation can be calcuated from this comparison as S(tl) ρ for very small ρ. After the ρ for the UV pump is ascertained to be less than 0.1, the MEG yield is calculated as described in the section “Calculations”.