Introduction

Focused ion beam (FIB) milling is a powerful lithographic technique with nanometre resolution1 and distinct advantages, especially when samples can potentially be damaged by wet chemicals that are required in electron-beam or photo-lithography processes. FIB lithography is often employed as the all-dry nanofabrication method for plasmonic2,3,4, photonic5,6 and microfluidic7 devices, in applications such as sensors, photodetectors, and light emitters8,9,10,11,12. Alongside these applications, recently FIB has shown great potential in surface modification and defect engineering in two-dimensional materials, especially in the transition metal dichalcogenides (TMDCs) family, with the aim to tailor their optical and electrical properties12,13,14,15,16,17,18,19. It has been shown that direct ion beam irradiation can controllably create chalcogenide and transition metal vacancies, thus manipulating the material’s stoichiometry. Ma et al. showed that argon ion irradiation can modify the optical properties of WS2 monolayers (MLs), where sulphur vacancies in ML WS2 create mid-bandgap states, resulting in enhanced saturable absorption in the near-IR wavelength region15. Furthermore, controlling stoichiometry-based defects can also tune the conductivity of 2D materials, sometimes even resulting in a change from a metallic to insulating phase. Stanford et al. showed that controlling the ion irradiation dose can selectively introduce precise local defects in few-layer WSe2, thereby locally tuning the resistivity and transport properties20. Additionally, focused helium ion beams have been used to deterministically create defects in MoS2, WS2 and WSe221. With helium ion irradiation, other than the expected local defects, the sputtered chalcogenide atoms also create an extended percolating network of defects, which results in edge states throughout the monolayers. Using FIB to control defect generation in 2D materials paves the way to fabricate nanoscale novel optoelectrical devices, including single-photon emitters, memory devices, resistors, and atomically thin circuits9,20,21,22.

Whilst FIB is the ideal tool for high-precision nanomaterial manipulation, a significant outstanding challenge is to understand the potential destruction to the materials, not only locally but also in extended areas beyond the target and discover how to minimise undesirable damage. The exceptionally delicate nature of these atomically thin 2D materials means that the lateral impact of sputtered ions and milled (and potentially redeposited) atoms becomes critical. Understanding and managing this lateral impact during the inherently destructive FIB process is key to maintaining high-performance nanodevices based on these 2D materials23,24. To the best of our knowledge, there are only two studies in the literature regarding quantifying the lateral damage area of ion beam lithography on 2D materials. Both studies are based on chemical-vapor-deposited (CVD) graphene25,26. It has been shown that the ions can reach a maximum lateral distance of approximately 30 μm. While Liao et al.25 attributed this effect to the deleterious tail of unfocused ions in the ion beam probe, Thissen et al.26 believe that sputtered gallium ions in the residual gas are the main cause of the long-distance lateral damage. To qualitatively determine the ion sputtering effect around the milled area, there are other studies of graphene that have used Raman spectroscopy to investigate the intensity ratio between the defect-induced Raman feature (D band) and the so-called native graphene feature, G band27,28. The D/G ratio of the Raman features decreased exponentially and reached a minimum value at around 15–30 μm away from the area milled by a focused gallium ion beam.

The aforementioned studies, however, are all based on graphene. In 2D TMDCs, although the local defects introduced by the ion beam have been studied, the extended lateral impact of the ion beam milling/lithography process, especially on their light-emitting properties remains unknown. In this letter, we performed focused gallium ion beam lithography on a large area monolayer WS2 with a range of ion beam currents. We report the impact of focused gallium ions on monolayer WS2 at different lateral locations, explore the different origins of these effects in detail and demonstrate how to control the damage.

Results

Steady-state photoluminescence and Raman spectroscopy of FIB-milled WS2

A number of WS2 samples are prepared on pre-marked SiO2-on-Si substrates (see METHODS). Figure 1b shows the PL spectrum measured from a pristine ML WS2 on SiO2-on-Si substrate, using a microPL setup29. The main PL peak energy of pristine ML WS2 is ~2.03 eV, corresponding to the neutral excitonic transition16,30,31,32,33, denoted as A0 in Fig. 1. Across the area of interest (within a circular region from the central milled hole, with a radius up to 300 μm), the A0 peak energy varies ± meV and the integrated intensities fluctuate by ±5%; this fluctuation is originated from wafer-scale ML CVD growth and the wet-transfer process. Additionally, we observe PL emission at lower energies (identified as two shoulders in Fig. 1b, peaking at 1.98 eV and 1.84 eV respectively), corresponding to trions and defect-bound states in ML WS230,31. The energy difference between the A0 peak (neutral excitons) and the AT peak (trions) is ~34 meV, in agreement with the literature30. The trions in as-grown TMDCs are attributed to native defects and TMDC–substrate interaction34,35. The lowest energy peak, defect-bound exciton peak DS, is attributed to S-deficiency induced emission, previously discussed in the S-based TMDCs, such as MoS2 and WS213,14,15,16,30,31,32,33,36.

Fig. 1: Steady-state photoluminescence from monolayer WS2 samples.
figure 1

a Optical microscope image of a wet-transferred ML WS2 on a pre-patterned SiO2/Si substrate, the scale bar is 100 µm; different shaded regions in a indicate the three identified zones—we divide the sample into the near zone (NZ), the dark zone (DZ) and the far-out zone (FO). b PL spectra of as-transferred ML WS2 (referred to pristine) on a SiO2/Si substrate, c Schematic drawing of the FIB lithography process on a WS2/SiO2/Si sample, d PL mapping of a FIB-milled WS2/SiO2/Si sample (Ga+ beam current is 30 pA) and e PL spectra measured at different locations, with the distance from the FIB milling position labelled on each spectrum. The green, red, and orange colours in b and e indicate the three emission peaks originating from neutral exciton (A0), trion (AT) and defect-state (DS), respectively. The peak wavelengths are marked with vertical dashed lines, and the maximum PL intensity values at each position are noted in e, highlighting the decrease of the PL intensity with decreasing the distance from the FIB-milled location.

A hole with 2 μm in diameter and 50 nm in depth was milled on the WS2/SiO2/Si samples, with various Ga+ beam currents in the range of 10–3000 pA (see METHODS). The lateral impact of the Ga+ FIB process on the optical properties of large area ML WS2 was investigated. After the FIB milling, we remeasured the PL, as shown in Fig. 1d, e. We divide the lateral area outside the milled hole into three zones: a “near” zone (0–5 μm radius around the milled hole, where 0 is the centre of the hole), a “dark” zone (further, in a 5–30 μm radius away from the hole), and a “far-out” zone (beyond 30 μm from the hole). Figure 1e shows the evolution of the PL spectra moving from the “near” to “far” zone. The total PL intensity and the intensity of the neutral exciton peak (A0) increases by factors of 3 and 10, respectively. In the “near” zone, the defect emission (DS) dominates and the ratio of its intensity to that of the neutral exciton increases by a factor of 4.6 when compared with the ‘far-zone’. The crystal defects, which lead to this broad emission (DS), as well as the deposition of Ga+ ions from the FIB, are expected to introduce p-type doping33 in the WS2 monolayer. This is consistent with previous reports of Ga+ irradiation of TMDC monolayers37. As the pristine CVD-grown monolayer on sapphire substrate is expected to be n-doped38, the disappearance of trion emission in the “near zone” is an indicator of p-type doping, which reduces the population of free electrons and thus leads to the absence of the AT peak. It is obvious that although the milling area is only 1 μm in radius, the laterally affected area is remarkably large, with distances of up to 30 μm showing changes in emission. This extended range of damage is caused by the deleterious tail of the ion beam, which consists of unfocused ions and ions in the residual gas in the vacuum system. This, in turn, results in the removal of atoms in the ML WS2 and ion contamination on the ML surface. Negligible shifts in the peak position of A0, AT and DS are attributed to artefacts of the fitting procedure and the difficulty in its implementation for low intensity PL.

To investigate the nature of the defect-bound emission DS at around 1.84 eV, we next carried out Raman measurements (see METHODS). Figure 2a shows the Raman spectra of pristine and milled ML WS2. Several first and second-order characteristic peaks were observed in the ML WS2 and marked in Fig. 2a32,39,40,41. The first- and second-order longitudinal acoustic modes, LA(M) and 2LA(M), seen here at 175 cm−1 and 349 cm−1, respectably, are identified as key markers for examining the prevalence of defects within ML WS242,43,44. The 2LA(M) mode is deconvolved from a broad peak situated around 355 cm−1 using multi-peak fitting, which also reveals a second sub-peak at 357 cm−1 identified as the in-plane vibrations of tungsten and sulphur atoms \((E_{2g}^1(\Gamma ))\)32,39,40,41. The lateral damage in ML WS2 by the FIB milling process is evident by tracking the deconvolved 2LA(M) and \((E_{2g}^1(\Gamma ))\) peak intensities and widths at various lateral positions (see Fig. 2e, f). While the peak position of the in-plane vibrations \((E_{2g}^1(\Gamma ))\) is not affected, the second-order longitudinal mode 2LA(M) is blue-shifted by just over 2 cm−1 from ~350 cm−1 in far-out regions, to ~352 cm−1 close to the FIB milling location, as shown in Fig. 2f. Like PL intensities, the Raman peak intensity of 2LA(M) is suppressed around the milled area, further highlighting the increasing density of defects42,43,44. Furthermore, analysing the LA(M) mode in the Pristine, the “far-out” zone (@ 200 μm), and the “near” zone (@ 5μm), as shown in Fig. 2b, presents a blue-shift of 1 cm−1 (half that shown in 2LA(M), as expected) and increases in peak intensity. Specifically, an increase in the ratio of peak intensity of LA(M) to A1g-LA(M) (230 cm−1), which here increases from 1:1.1 in pristine, to 1:1.26 in the “far-out” zone, to 1:2.28 in the “near” zone, has previously been identified as a robust marker of increased defects in ML WS242,44. Combined with a significant decrease in overall photoluminescence and disappearance of the negatively charged trion close to the FIB epicentre, as shown in Fig. 1, the evidence provided here via analysis of the Raman spectra, indicates an increase in vacancy-phonon scattering within the 30 µm radius area (in the “near” and “dark” zones). This is due to the higher density of both sulphur and tungsten vacancies created by the deleterious tail of the ion beam42,44.

Fig. 2: Raman spectroscopy.
figure 2

a Raman spectra of pristine and FIB-milled ML WS2 (5 and 200 μm away from the milled area); b zoom-in of the Raman peak (LA(M)) at 175 cm−1; c Raman peak around 355 cm−1 deconvolved it into two peaks: 2LA (M) and \((E_{2g}^1(\Gamma ))\); d peak intensity, e peak width (full width at half maximum, FWHM) and f peak frequency of 2LA (M) as a function of lateral position.

Time-resolved photoluminescence mapping with ultra-high spatial resolution

We further investigated the ion beam damage mechanisms around the milled area by time- and spatially resolved PL measurements. These measurements were performed using a sample-scanning confocal fluorescence time-correlated single-photon counting (TCSPC) setup, shown in Fig. 3a (more details in METHODS). As clearly seen in the PL mapping (Fig. 3b), there is a ring of higher intensity fluorescence surrounding the milled hole. To help understand the origin of this bright ring in the near zone, we split the collected PL using a dichroic filter centred at 638 nm (this wavelength being just between the trion and the defect-bound exciton peak wavelengths) to allow us to identify the collected photons at shorter and longer wavelengths simultaneously. With this configuration, we can produce a colour ratio for the PL images, which indicates the “ring” emission is primarily comprised of photons at shorter wavelengths (<638 nm) (see Fig. 3c). Based on the wavelength information, the origin of this “ring” emission could be either neutral excitons or trions, or a combination of both. However, it is known that the trion-induced emission is slower than the neutral exciton emission45,46. The time-resolved decay analysis confirms that the “ring” is mainly trion emission and the decay of the ring emission is significantly slower than the emission in the “far-out” zone, which mainly consist of neutral excitons (see Fig. 3d and Table 1). Unlike the native defect and substrate-induced trions, there are two possible explanations for the origin of this “ring”: first, the positively charged Ga ions depositing and charging the monolayer observed via an electrostatic force microscope, and second, the free carriers accumulating on the edge, thus forming more edge states, resulting in enhanced trion emission; similar effects have been observed in other TMDCs30,35,46,47. In the dark zone, the vacancy-based defect states result in a much lower total intensity and a shorter lifetime48,49 (Table 1).

Fig. 3: Time-resolved photoluminescence from FIB-milled ML WS2.
figure 3

a Experimental setup of the time-resolved fluorescence confocal microscope; b PL mapping of a FIB-milled sample, with a scale bar of 10 µm; c PL intensity profile at positions along the dashed line in b as a function of lateral position, less than (blue) and greater than (pink) 638 nm; d the time-resolved decay curves at three locations for wavelengths less than and greater than 638 nm: in the far-out zone (yellow squares), in the dark zone (red triangles), and on the “ring” (green circles).

Table 1 Exponential lifetimes, τ, and pre-exponential amplitudes in parenthesis of the PL emissions at different locations, fitted with two exponential components.

Impact of FIB current and energy dispersive X-Ray mapping

To gain a comprehensive understanding of the lateral damage in the extended area as a function of ion beam current, we performed the FIB milling process on ML WS2 samples with a variety of beam currents, ranging from 10 pA to 3 nA. The same trend was observed in the samples milled with beam currents ranging from 10 up to 100 pA, i.e. a linear increase of PL moving away from the milling position in the dark zone, then reaching saturation in the far-out zone, as shown in the normalised PL intensity trend in Fig. 4a. While the size of the short-range damage area (the dark zone) remains unaffected by the different FIB conditions, we observe a current-dependent total emission intensity within the far-out zone. The higher the ion beam current that is used, the less PL intensity is measured. Moreover, the FWHM of the PL spectrum is another indicator of the ion current-dependent damage in the far-out zone. As shown in Fig. 4c, the FWHM of the PL spectrum broadens due to the increased defect-bound exciton emissions. It is evident that during the milling process, the ion-beam current plays a crucial role in the lateral damage effect on the ML WS2, contrary to the studies carried out on graphene25,26. This secondary far-range damage is due to sputtered Ga+. In a dual-beam-equipped FIB system, the sputtered Ga ions can spread to hundreds of μm away from the milled area. This has been experimentally observed using a time-of-flight secondary ion mass spectroscopy in a similar dual beam FIB50. This wider range of ion-sputtering induces secondary damage due to the Ga+ and milled atoms that were previously deposited on surfaces inside the vacuum chamber (such as the SEM column, the probes etc.) being redeposited on the ML WS2. Redeposition of the Ga+ can be the main reason for the long-range lateral damage, and this can be eliminated by achieving a better vacuum in the chamber. Here, by using a lower beam current, the time required to mill the same amount of material increases and therefore it results in additional evacuation of the secondary sputtered ions from the surfaces and the residual gas in the chamber, leading to smaller overall damage of the ML WS2. The Ga+ density on different samples milled with different ion beam currents measured by energy dispersive X-Ray spectroscopy, is noticeably different, as shown in Fig. 4d. While only one type of Ga+ distribution (exhibited as a sharp peak at the milling position) is observed on the low current samples, an additional wide-ranged Ga+ distribution is detected on the high current samples, which causes secondary damage to the TMDC MLs.

Fig. 4: PL dependency on gallium ion beam current.
figure 4

a The emission intensity of the neutral exciton as a function of position, with a range of ion beam currents tested; inset is with the intensity normalised to the maximum value on each sample; b Integrated PL intensity and c FWHM of the PL spectra in the “dark” and “far-out” zone as a function of ion beam current. d Distribution of Ga+ on the 30 pA and 3 nA ion beam current samples. The edges of the “dark” zone are marked with two dashed lines. The inset shows two energy dispersive X-Ray (EDX) mapping after a smiley face milled with the corresponding current. The scale bar is 2 μm.

Discussion

In conclusion, we have observed the lateral damage effects of a focused ion beam on a large-area CVD grown and transferred monolayer of WS2. Three distinct zones situated at different distances from the milling location were clearly identified and the distance-dependent damage mechanisms were explained. The main mechanism for short-range (radius of 0–30 μm) damage is the removal of tungsten and sulphur atoms in the monolayer by the primary ions and ion contaminants on the monolayer surface. Long-range (radius >30 μm) damage sustained is caused by the redeposition of the secondary ions from the residual gas and the ion-electron beam column surfaces. The PL emission was significantly reduced, down to 10% in the short range, however, a bright ring-shaped feature, with half of the original emission intensity, was observed at the edge of the milled area. It is understood that this observed “ring” is primarily trion emission at a longer wavelength compared to the original emission, due to the charging effect from sputtered Ga+ deposition. This suggests the focused ion beam can be used to tailor the optical properties of TMDC monolayers by creating three spatially and spectrally resolvable emission states with distinct decay lifetimes. We also conclude that while short-range damage is an inevitable consequence of FIB milling, the impact of the weak (secondary) damage can be prevented by reducing the ion beam current during the FIB process. These results pave the way for the use of heavy ion beam-based tools to fabricate novel wafer-scale optoelectrical devices based on the 2D TMDC materials, such as single-photon emitters, memory devices, resistors, and atomically thin circuits, on a wafer scale.

Methods

Sample preparation

Monolayer WS2 was grown on a 2-inch sapphire substrate by AIXTRON Ltd. using a Close Coupled Showerhead metal organic vapour deposition reactor. The uniformity of as-grown ML WS2 across the 2-inch wafer was assessed using photoluminescence and Raman spectroscopy. 300 nm SiO2-on-Si substrates and SiO2 substrates are pre-patterned with markers, using electron beam lithography (EBL) with a resist layer (AR-P, Allresist GmbH). The markers are essential for the ion-beam milling process and locating the milling area afterwards. We use a Voyager EBL system (Raith GmbH) to define the markers then etch them into the substrates using reactive ion etching, in a 29:1 mixed gas flow of CHF3 and O2.

Centimetre-sized monolayers of WS2 are then transferred from the sapphire substrate onto pre-marked SiO2-on-Si or SiO2 substrates, using a wet-transfer process with a polymethyl methacrylate (PMMA) layer as a carrier. The PMMA layer is then removed in a warm acetone bath before the focused ion beam milling process.

Focused ion beam milling

We use a dual-beam FIB-SEM system (Versa3D, FEI) to perform the ion beam milling. The Ga+ beam acceleration voltage of the system is 30 kV. Ga+ beam currents in the range of 10–3000 pA are tested for the milling process. An area of 2 μm in diameter and 50 nm in depth is milled on each sample, with a constant dose of 333.4 pC/μm2 (a volume-per-dose of 240 nm3/nC).

Steady-state photoluminescence spectroscopy

We use a home-built micro-PL setup to excite the monolayer with a 532 nm CW laser (Novanta Photonics gem532) and collect the PL from the samples, via a 50x objective (Numerical Aperture, NA = 0.55). The excitation laser beam is focused to a spot of ~1.5 μm in diameter on the sample placed on a XYZ piezo stage. We record the PL spectra with a spectrometer (Acton Spectrapro 2750) and a thermoelectric cooled charge-coupled device (CCD, Andor IDUS 420A-BV) at different locations on the sample. Steady-state photoluminescence mapping was carried out in another home-built micro-PL setup with an excitation via a 532 nm CW laser (Cobolt) focused to a 1.4 µm spot on the sample. The emitted light was collected by a 100x objective (NA = 0.8), passed through a spectrometer (Princeton Instruments, SP2750) and focused onto a liquid nitrogen cooled CCD (Princeton Instruments, PyLoN). The final photoluminescence map was compiled by scanning the excitation and collection spots across the sample at a step of 2.5 µm. The recorded spectra were subsequently integrated from 590 nm to 700 nm.

Raman spectroscopy

For free-space ultra-low frequency Raman spectroscopy, the sample is placed on a motorized xyz stage (STANDA-8MTF), which allows the automated mapping of the sample surface. Sample is excited using a 532 nm laser (Cobolt, 04–01) with a 10 cm−1 Bragg notch filters (OptiGrate, BragGrate). The beam is then focussed onto the sample using a 50x objective (NA = 0.55), providing a spatial resolution of ≈ 1 µm. Laser power at the sample is typically 1 mW (Power density ≈ 1.27 × 105 Wcm−2). Emission is collected by the same objective. The laser line is attenuated with further 10 cm−1 Bragg notch filters and is then coupled to a spectrometer (Princeton Instruments, SP2750) equipped with a liquid nitrogen cooled CCD (Princeton Instruments, PyLoN). An 1800 g/mm grating used provides a spectral resolution of ≈ 0.4 cm−1.

Time-resolved photoluminescence spectroscopy

The fluorescence lifetime and decay data are acquired using a time-correlated single photon counting (TCSPC) using a picosecond event timer (HydraHarp 400 by PicoQuant GmbH) with fluorescence detected on two single photon avalanche photodiodes (Micro Photon Devices Srl). These are integrated with an inverted Nikon confocal microscope (Ti2-U), with a CFI Plan Apochromat 100x oil-immersion objective (Numerical Aperture = 1.45). Excitation is provided by a 405 nm laser diode (LDH-D-C-405S, PicoQuant GmbH) driven by a Sepia II (PicoQuant GmbH), at a 40 MHz repetition rate with ~70 ps (full-width half-maximum) pulses. The laser light is spatially expanded and fills the back-aperture of the objective. The sample is scanned with a 2D piezo stage (P-733.2CD, Physik Instrumente GmbH) to generate a PL map. The collected PL is split into two paths using a dichroic filter centred at 638 nm. With this configuration, we can produce a colour ratio for the PL images for wavelengths <638 nm and >638 nm along with associated PL decays.

Energy-dispersive X-ray spectroscopy

We use a Silicon Drift Detector (EDAX Octane Super), which is attached on the dual-beam FIB-SEM system (Versa3D, FEI) for Energy-dispersive X-ray (EDX) spectroscopy. The acceleration voltage of the electron beam is 10 kV. The step size is 100 nm for the line scans, and the mapping resolution is 1024 × 800.