Abstract
An artificial intelligence (AI) system that reconstructs virtual 3D thin-section CT (TSCT) images from conventional CT images by applying deep learning was developed. The aim of this study was to investigate whether virtual and real TSCT could measure the solid size of early-stage lung adenocarcinoma. The pair of original thin-CT and simulated thick-CT from the training data with TSCT images (thickness, 0.5–1.0 mm) of 2700 pulmonary nodules were used to train the thin-CT generator in the generative adversarial network (GAN) framework and develop a virtual TSCT AI system. For validation, CT images of 93 stage 0–I lung adenocarcinomas were collected, and virtual TSCTs were reconstructed from conventional 5-mm thick-CT images using the AI system. Two radiologists measured and compared the solid size of tumors on conventional CT and virtual and real TSCT. The agreement between the two observers showed an almost perfect agreement on the virtual TSCT for solid size measurements (intraclass correlation coefficient = 0.967, P < 0.001, respectively). The virtual TSCT had a significantly stronger correlation than that of conventional CT (P = 0.003 and P = 0.001, respectively). The degree of agreement between the clinical T stage determined by virtual TSCT and the clinical T stage determined by real TSCT was excellent in both observers (k = 0.882 and k = 0.881, respectively). The AI system developed in this study was able to measure the solid size of early-stage lung adenocarcinoma on virtual TSCT as well as on real TSCT.
Similar content being viewed by others
Introduction
The clinical TNM classification of malignant tumors (TNM) of primary lung cancer plays an important role in therapeutic strategy decisions1,2,3. The diagnosis of the tumor (T) factor is particularly important in early-stage (0–I) lung cancer in determining the surgical procedure4,5. The TNM staging can be clinical (c-stage) and/or pathologic (p-stage), and the former is determined by the maximal size of the solid component (solid size) on thin-section CT (TSCT), while the latter is determined by the maximal invasive size on histopathological specimens in the eighth version of the Union for International Cancer Control (UICC) TNM classification4,6,7,8.
The solid size should be measured three-dimensionally using TSCT images with a slice thickness of 1 mm or less and multiplanar reconstruction (MPR) images5,9,10. However, sequential TSCT images increase the data volume and may cause problems in the transmission and storage of picture and archiving communication systems (PACS). Compared to 5 mm-thick conventional CT, 0.5–1 mm thick TSCT increases data volume by 5 × to 10 × fold. Therefore, TSCT is recommended for evaluation of solid nodules, but CT performed on 5-mm-thick sections is still common in clinical practice11,12. If the solid size can be measured as accurately as the TSCT on conventional 5-mm-thick CT images, the problem can be solved.
In recent years, many attempts have been made to improve the image quality of chest CT by applying artificial intelligence (AI) techniques such as deep learning (DL)13,14,15,16,17,18. Therefore, we attempted to generate virtual TSCT and MPR images from conventional CT images of lung cancer using DL. The purpose of this study was to investigate whether virtual TSCT can measure the solid size of early-stage lung adenocarcinoma.
Methods
Using AI to generate virtual TSCT
A three-dimensional (3D) conditional generative adversarial network (GAN)-based algorithm was applied to virtually generate thin-section CT from TSCT19. As training data, TSCT images (thickness, 0.5–1.0 mm) of 2700 pulmonary nodules prior to December 2016 were collected from the PACS of our institution. Thick-slice images with thickness/intervals of 3.0–8.0 mm were randomly simulated from the TSCT image using interpolation processing. The pair of original thin-CT and simulated thick-CT was used to train the thin-CT generator in the GAN framework, where the discriminator takes the roll to let the generator produce virtual thin-CT that is difficult to distinguish from the real thin-CT (Fig. 1). We incorporated the conditioning labels (ex. slice thickness) associated with the input CT into conditional adversarial training to improve the accuracy of the interpolation.
Validation case collection
Using the retrieval function of PACS, we searched our institutional database for CT and pathological reports of patients with pathologically confirmed, surgically resected stage 0–I lung adenocarcinoma based on the TNM classification in the 8th version of UICC between January 2017 and March 2018. Consequently, CT images of 93 patients with early-stage lung adenocarcinoma were collected.
The clinical records of all selected cases were reviewed to obtain data on the patients’ age, sex, location of the tumor, date of preoperative CT, and surgery. Based on the pathological reports, the invasive size of the tumor was recorded, and pathological T stage (pTis, pT1mi, pT1a, pT1b, pT1c, and pT2a) was determined (Table 1).
Preoperative CT scans were performed with four types of CT scanners (SOMATOM Definition Flash, Siemens Healthcare; Aquilion, Canon Medical Systems) in the craniocaudal direction with inspiratory apnea. No contrast medium was used. The reconstructed images were 5-mm thick (conventional CT) and equal to or less than 1-mm thick (real TSCT) in the routine at our institution (Table 2).
Conventional 5 mm-thick CT, virtual TSCT and real TSCT are shown in Figs. 2, 3, 4 and 5. The AI algorithm output the same results in multiple tests to the same conventional thick CT. The time required to create a 3D virtual TSCT from a conventional CT using AI was less than 5 s per case.
Solid size measurement and clinical T staging on a 3D workstation
All reconstructed TSCT images were transferred to a 3D workstation (VINCENT V4.3, Fujifilm Medical). The CT images were displayed with window level and width settings of 1500 and − 600 HU and reviewed by two radiologists with 5 and 26 years of experience as observers A and B, respectively. Observer B was a chest radiologist who annually staged over 400 cases of lung cancer in our institution. First, two observers independently measured the maximal solid size on the MPR images (axial, coronal, and sagittal plane) obtained from virtual TSCT images. Second, they independently measured the maximal solid size on conventional CT images. In addition, observer A and B measured the maximal solid size on the MPR images obtained from the real TSCT images. To avoid memory effects, each reading experiment was carried out at intervals of at least one week.
The clinical T stage (cTis, cT1mi, cT1a, cT1b, cT1c, and cT2a) was defined by observer B based on the solid size measured by real TSCT, and this was used as the gold standard for clinical staging. In addition, each clinical T stage was determined by the solid size measured by observers A and B using virtual TSCT and conventional CT, respectively.
Statistical analysis
First, the agreement between the two observers for solid size measurement was analyzed using the intraclass correlation coefficient (ICC). Second, the Pearson correlation coefficient was calculated with real TSCT for conventional CT and virtual TSCT, and the values were compared using the z-test for each observer. Analysis of covariance (ANCOVA) was used to compare between observers and conventional CT and virtual TSCT the solid size measurement. Third, the correspondence rates of the c-stage between the real TSCT and virtual TSCT and between the real TSCT and conventional CT were analyzed using the kappa coefficient (k). Similarly, the correspondence rate between the p- and c-stages was analyzed using k. The degree of agreement was interpreted, as follows: less than 0.20, poor agreement; 0.21–0.40, fair agreement; 0.41–0.60, moderate agreement; 0.61–0.80, good agreement; and 0.81–1.00, almost perfect agreement.
Analyses were performed using the commercial statistical software Excel 2013 (Microsoft Corporation), a statistical add-in (BellCurve version 3.20; Social Survey Research Information Corp.), and SPSS version 23 (IBM Corp.). Statistical significance was set at P < 0.05.
Ethics approval and consent to participate
This retrospective study was approved by the institutional review board of Nagoya University Graduate School of Medicine, and written informed consent was waived (approval no. 2017-0471-3). The study was conducted according to the relevant guidelines and regulations.
Results
The solid size on the conventional CT measured by observer A and B were 8.3 ± 7.9 mm and 8.4 ± 8.2 mm, respectively. The solid size on the virtual TSCT measured by observer A and B were 12.5 ± 10.0 mm and 12.4 ± 10.2 mm, respectively. The solid size on the real TSCT measured by observer A and B were 11.6 ± 9.5 mm and 11.8 ± 9.6 mm, respectively. For solid size measurements, the agreement between the two observers showed an almost perfect agreement on the conventional CT, the virtual TSCT, and real TSCT (ICC = 0.950, P < 0.001; ICC = 0.967, P < 0.001; and ICC = 0.962, P < 0.001, respectively). The invasive size on the postoperative pathology specimen was 13.7 ± 9.2 mm.
The solid size measured on the conventional CT tended to be smaller, especially for tumors with a solid size > 2 cm (Fig. 6). The Pearson correlation coefficient with real TSCT of observer A was 0.88 for conventional CT and 0.95 for virtual TSCT, and virtual TSCT had a significantly stronger correlation than that of conventional CT (P = 0.003). Similarly, the Pearson correlation coefficient of observer B showed a value of 0.90 for conventional CT and 0.96 for virtual TSCT, and virtual TSCT had a significantly stronger correlation than that of conventional CT (P = 0.001). ANCOVA of the difference in the solid size between observers and between conventional CT and virtual TSCT revealed no significant variation between observers (P = 0.930), whereas a significant difference was observed between conventional CT and virtual TSCT (P < 0.001).
The degree of agreement between the clinical T stage determined by conventional CT and the clinical T stage determined by real TSCT was good in both observers (k = 0.757 and k = 0.780, respectively; Table 3). On the other hand, the degree of agreement between the clinical T stage determined by virtual TSCT and the clinical T stage determined by real TSCT was excellent in both observers (k = 0.882 and k = 0.881, respectively; Table 3).
The degree of agreement between the clinical T stage determined by conventional CT and the pathological T stage determined by the invasive size of postoperative pathological specimens was moderate in both observers (k = 0.449 and k = 0.451, respectively; Table 4). In contrast, the degree of agreement between the clinical T stage determined by virtual TSCT and pathological T stage was moderate in both observers (k = 0.591 and k = 0.591, respectively; Table 4). Additionally, the degree of agreement between the clinical T stage determined by real TSCT and pathological T stage was moderate in both observers (k = 0.524 and k = 0.597, respectively; Table 4).
Discussion
In this study, we applied AI to convert 5 mm-thick conventional CT images into virtual TSCT images and investigated whether this could accurately measure the solid size of lung adenocarcinoma. The results showed that the solid size measurements of the two observers on virtual TSCT were almost identical, and the correlation between virtual TSCT and real TSCT measurements was significantly higher than that of conventional CT. The agreement between clinical T stage determined by virtual TSCT and clinical T stage determined by real TSCT was excellent. Furthermore, the clinical T stage of virtual TSCT had a higher correlation with the pathological T stage than the T stage of conventional CT.
Virtual TSCT is an AI technique that applies deep learning to convert thick-slice CT into TSCT images. We have succeeded in synthesizing virtual TSCT images that are similar to real TSCT from thick-slice CT images by training a set of averaged 3.0–8.0 mm-thick images reconstructed from TSCT images using a number of lung nodule cases as training data. For both observers, the correlation between the measurements of virtual TSCT and real TSCT was significantly higher than that between conventional CT and real TSCT. Various factors that make measurement of the solid size of lung cancer have been reported10,20. For tumors larger than 2 cm, the solid size measured by conventional CT tended to be smaller. The virtual TSCT not only improves the spatial resolution of the axial section, but also improves the spatial resolution of the craniocaudal direction, which enables accurate measurement of the solid size with MPR images. Naturally, there was an excellent correlation between the clinical T stage determined by virtual TSCT and the clinical T stage determined by real TSCT.
The correlation between the clinical T stage determined by virtual TSCT and the pathological T stage was moderate but was higher than the correlation with the clinical stage determined by conventional CT. However, it was comparable to the clinical T stage determined by real TSCT. Several previous studies have reported a difference between clinical TNM stages and pathological stages7,10,15,21. Ahn et al. reported that the kappa values for agreement between clinical T-stage and pathological T-stage were 0.53–0.6910. In the present study, the kappa values for agreement between clinical T stage determined by virtual TSCT and the pathological T stage was 0.59 in both observers, which was consistent with the results of Ahn et al. Interestingly, in the article by Funai et al., clinical T-stage based on TSCT was more correlated with the postoperative recurrence than with the pathological T-stage based on the invasive size21. Therefore, we speculate that the clinical T-stage measured by virtual TSCT may also be correlated with prognosis. Further investigation is needed to determine whether measurement of the solid size by virtual TSCT is related to the prognosis.
Not all chest CTs are acquired with TSCT. There are several hospitals that only scan conventional CT for screening examinations. The conventional CT images obtained in the past could not be reconstructed into TSCT images. Lung nodules are often incidentally detected on conventional CT. In such cases, it is much faster to create a virtual TSCT on PACS than to reconstruct a real TSCT again from the raw CT data. In this study, we examined nodular lesions, but the virtual TSCT technique could also be applied to diffuse lung diseases. Furthermore, small pulmonary nodules are often missed on conventional thick-slice CT, but virtual TSCT is expected to improve nodule detection compared to conventional CT because of the improved 3D appearance of the nodules. We are prepared to further study the clinical usefulness of virtual TSCT.
This study had several limitations. First, it was a retrospective, single-center study. We used conventional CT images acquired from several CT systems; however, we could not try the CT systems from all manufacturers. Second, the solid size was measured manually by only two radiologists. Although the agreement between two observers showed an almost perfect agreement, to minimize bias introduced by individual difference, reading experiments with a multiple readers may have been necessary. Also, computer-aided diagnosis may be able to measure it more accurately5. Therefore, we plan to improve the software to measure the solid size and volume automatically from virtual TSCT. Finally, we only focused on the solid size of lung cancers and did not examine the edge characteristics, such as spiculation. The AI algorithm should improve upon this part by increasing the training data. The virtual TSCT still requires ongoing refinement. The error range of the virtual TSCT can extend up to 9 mm, potentially leading to unnecessary surgeries. The integration of AI in medicine can sometimes result in unforeseen risks.
In conclusion, we developed an AI system that reconstructs virtual TSCT images from conventional CT images by applying DL. It was possible to measure the solid size of early-stage lung adenocarcinoma on virtual TSCT as well as on real TSCT, which could be useful for the clinical TNM staging of lung cancer.
Data availability
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- TNM:
-
TNM classification of malignant tumors
- UICC:
-
Union for International Cancer Control
- TSCT:
-
Thin-section CT
- MPR:
-
Mutiplanar reconstruction
- PACS:
-
Picture and archiving communication systems
- AI:
-
Artificial intelligence
- DL:
-
Deep learning
- 3D:
-
Three-dimensional
- GAN:
-
Generative adversarial network
- ICC:
-
Intraclass correlation coefficient
- k:
-
Kappa coefficient
References
Umakoshi, H. et al. FDG PET/CT overcomes discordance between clinical and pathologic TNM classification of small-size primary lung cancer: Influence on postoperative prognosis. Clin. Lung Cancer 19, e37–e45 (2018).
Asamura, H. et al. The International Association for the Study of Lung Cancer Lung Cancer Staging Project: Proposals for the revision of the N descriptors in the forthcoming 8th edition of the TNM classification for lung cancer. J. Thorac. Oncol. 10, 1675–1684 (2015).
Eberhardt, W. E. et al. The IASLC Lung Cancer Staging Project: Proposals for the revision of the M descriptors in the forthcoming eighth edition of the TNM classification of lung cancer. J. Thorac. Oncol. 10, 1515–1522 (2015).
Travis, W. D. et al. The IASLC Lung Cancer Staging Project: Proposals for coding T categories for subsolid nodules and assessment of tumor size in part-solid tumors in the forthcoming eighth edition of the TNM classification of lung cancer. J. Thorac. Oncol. 11, 1204–1223 (2016).
Kamiya, S. et al. Computer-aided volumetry of part-solid lung cancers by using CT: Solid component size predicts prognosis. Radiology 287, 1030–1040 (2018).
Iwano, S. et al. Utility of metabolic parameters on FDG PET/CT in the classification of early-stage lung adenocarcinoma: Prediction of pathological invasive size. Clin. Nucl. Med. 44, 560–565 (2019).
Aokage, K. et al. Clinical and pathological staging validation in the eighth edition of the TNM classification for lung cancer: Correlation between solid size on thin-section computed tomography and invasive size in pathological findings in the new T classification. J. Thorac. Oncol. 12, 1403–1412 (2017).
Aokage, K. et al. Influence of ground glass opacity and the corresponding pathological findings on survival in patients with clinical stage I non-small cell lung cancer. J. Thorac. Oncol. 13, 533–542 (2018).
Park, S. et al. CT evaluation for clinical lung cancer staging: Do multiplanar measurements better reflect pathologic T-stage than axial measurements?. Korean J. Radiol. 20, 1207–1215 (2019).
Ahn, H. et al. Effect of computed tomography window settings and reconstruction plane on 8th edition T-stage classification in patients with lung adenocarcinoma manifesting as a subsolid nodule. Eur. J. Radiol. 98, 130–135 (2018).
Park, S. et al. Computer-aided detection of subsolid nodules at chest CT: Improved performance with deep learning-based CT section thickness reduction. Radiology 299, 211–219 (2021).
Goo, J. M. Deep learning-based super-resolution algorithm: Potential in the management of subsolid nodules. Radiology 299, 220–221 (2021).
Vonder, M., Dorrius, M. D. & Vliegenthart, R. Latest CT technologies in lung cancer screening: Protocols and radiation dose reduction. Transl. Lung Cancer Res. 10, 1154–1164 (2021).
Matsukiyo, R. et al. Deep learning-based and hybrid-type iterative reconstructions for CT: Comparison of capability for quantitative and qualitative image quality improvements and small vessel evaluation at dynamic CE-abdominal CT with ultra-high and standard resolutions. Jpn. J. Radiol. 39, 186–197 (2021).
Hart, J. L. et al. The effect that pathologic and radiologic interpretation of invasive and non-invasive areas in lung adenocarcinoma has on T-stage and treatment. Ann. Diagn. Pathol. 54, 151799 (2021).
Franck, C. et al. Pulmonary nodule detection in chest CT using a deep learning-based reconstruction algorithm. Radiat. Prot Dosimetry 195, 158–163 (2021).
Singh, R. et al. Image quality and lesion detection on deep learning reconstruction and iterative reconstruction of submillisievert chest and abdominal CT. AJR Am. J. Roentgenol. 214, 566–573 (2020).
Lenfant, M. et al. Deep learning versus iterative reconstruction for CT pulmonary angiography in the emergency setting: Improved image quality and reduced radiation dose. Diagnostics (Basel) 10, 558 (2020).
Kudo, A., Kitamura, Y., Li, Y. Z., Iizuka, S. & Simo-Serra, E. Virtual thin slice: 3D conditional GAN-based super-resolution for CT slice interval. Lect. Notes Comput. Sci. 11905, 91–100 (2019).
Hamanaka, K. et al. Interobserver size measurement variability in part-solid lung adenocarcinoma using pre-operative computed tomography. J. Thorac. Dis. 11, 2924–2931 (2019).
Funai, K., Kawase, A., Mizuno, K., Koyama, S. & Shiiya, N. 8th Edition tumor, node, and metastasis T-stage prognosis discrepancies: Solid component diameter predicts prognosis better than invasive component diameter. Cancers (Basel) 12, 1577 (2020).
Acknowledgements
The authors thank Editage (https://www.editage.jp) for English language editing.
Funding
This study was funded by a research collaboration with Fujifilm Corporation (No. 2609De-05c).
Author information
Authors and Affiliations
Contributions
S.I. conceived of the present idea. S.N. supervised the project. S.I., S.K., and R.I. acquired, analyzed and interpreted the data. A.K., Y.K. and K.N. contributed to the development of AI software. S.I. was a major contributor in writing the manuscript. S.K., R.I., and S.N. contributed to the revision of the manuscript. All authors have read and approved the final article.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Iwano, S., Kamiya, S., Ito, R. et al. Measurement of solid size in early-stage lung adenocarcinoma by virtual 3D thin-section CT applied artificial intelligence. Sci Rep 13, 21709 (2023). https://doi.org/10.1038/s41598-023-48755-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-48755-5
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.