Abstract
The most important challenge faced in designing orthopedic devices is to control the leaching of ions from the substrate material, and to prevent biofilm formation. Accordingly, the surgical grade stainless steel (316L SS) was electrophoretically deposited with functional composition of biopolymers and bioceramics. The composite coating consisted of: Bioglass (BG), hydroxyapatite (HA), and lawsone, that were loaded into a polymeric matrix of Xanthan Dialdehyde/Chondroitin Sulfate (XDA/CS). The parameters and final composition for electrophoretic deposition were optimized through trial-and-error approach. The composite coating exhibited significant adhesion strength of “4B” (ASTM D3359) with the substrate, suitable wettability of contact angle 48°, and an optimum average surface roughness of 0.32 µm. Thus, promoting proliferation and attachment of bone-forming cells, transcription factors, and proteins. Fourier transformed infrared spectroscopic analysis revealed a strong polymeric network formation between XDA and CS. scanning electron microscopy and energy dispersive X-ray spectroscopy analysis displayed a homogenous surface with invariable dispersion of HA and BG particles. The adhesion, hydrant behavior, and topography of said coatings was optimal to design orthopedic implant devices. The said coatings exhibited a clear inhibition zone of 21.65 mm and 21.04 mm with no bacterial growth against Staphylococcus aureus (S. Aureus) and Escherichia coli (E. Coli) respectively, confirming the antibacterial potential. Furthermore, the crystals related to calcium (Ca) and HA were seen after 28 days of submersion in simulated body fluid. The corrosion current density, of the above-mentioned coating was minimal as compared to the bare 316L SS substrate. The results infer that XDA/CS/BG/HA/lawsone based composite coating can be a candidate to design coatings for orthopedic implant devices.
Similar content being viewed by others
Introduction
Musculoskeletal disorders affect ~ 1.7 billion people globally. The Agency for Healthcare Research and Quality reported 750,000 knee replacements in 2017 in the US1,2. Hip and knee replacements are among the most performed surgeries across the globe, with the knee replacement market projected to reach USD 17.45 billion by 20302,3.
Magnesium (Mg), titanium (Ti), cobalt-chromium (Co-Cr), and stainless steel (SS) can be used to fabricate orthopedic implants, including fixators (internal/external), bone plates, prosthesis, etc. Surgical grade SS (316L SS) has properties that make it an attractive option for orthopedic implants. It is bioinert, biocompatible, and has high corrosion resistance, which makes it not produce a strong immunological response or any toxicity in the body. Its mechanical properties (durability and high tensile strength), sterilizability and low cost make it viable for orthopedic implants4,5,6. SS implants are coated with biopolymers and bio-ceramics to promote biocompatibility and bioactivity. Biopolymers such as chitosan (CHI), gelatin, and poly methyl methacrylate can provide a strong network to load nanoparticles like liposomes, graphene oxide (GO), BG, and glycosaminoglycans (GAGs)7,8. Through in-vivo and in-vitro testing, biopolymer-based coatings have been proven to increase corrosion resistance and bioactivity. In this context, a robust polymeric network of XDA and CS is proposed to load HA/henna and BG on the facet of stainless-steel implants. XDA possesses an adhesive nature and varying levels of antioxidant activity depending on its environment. XDA also provides more potential crosslinking sites through the presence of aldehyde functional groups, allowing for a strong network for loading nanoparticles9,10,11.
GAGs like heparin sulfate, CS, and hyaluronan were used as biomaterials in different biological applications. CS being the native GAG of bone matrix and cartilage was preferred in the current study. CS possesses anti-apoptotic and anti-inflammatory properties along with boosting production of proteoglycans. Therefore, it is used in various bone diseases to assist tissue regeneration12,13,14,15,16. BG are efficient inorganic materials used for bone tissue engineering. They either dissolve or diffuse ions for exchange, promoting osteoblast proliferation, matrix mineralization, and bone marrow stem cell differentiation17,18,19. The release and diffusion of Ca and P ions are vital in prompting growth of apatite-like crystals20,21,22.
Different minerals like octa-calcium, tricalcium phosphate, and HA were used earlier in the related context. HA was used because of its higher bioactivity, stability and osteoinductive property that helps bone regeneration23,24. A variety of antimicrobial agents exist in the form of herbal extracts from plants, such as garlic, ginger, clove, thyme, etc., that are used for their antibacterial efficacy25. The natural herbs are safer than synthetic drugs to prevent bacterial growth, due to the minimum toxicity of natural herbs. The natural herb used for the reported coating is henna (Lawsonia inermis). Henna exhibits a wide range of antimicrobial activities against both Gram-positive and Gram-negative bacteria26,27,28. The core chemical components of henna are 2-hydroxynapthoquinone (lawsone). Quinones are abundantly present in henna and are responsible for their high antibacterial activity26,29. EPD was utilized in this study as it is a cost-efficient and effective coating technique, that employs an electric field to move and deposit the charged particles/molecules over the electrode being charged contrarily. Deposition potential along with deposition time directs the structure, topography and width of stated coating30,31,32. EPD can deposit bioceramics (BG, HA, and Ca phosphate cements), biopolymers (XDA, CS, CHI, alginate etc.), and the co-deposition of both from single suspension30,32,33,34,35. The said polymers or their matrix/network encapsulating drugs/bioceramics can enhance the resistance of 316L SS toward corrosion36. Souza et al.37 fabricated CHI/Xanthan (Xn)-based scaffolds as periosteum substitutes and it was shown that scaffolds exhibited osteoinductive behavior. Molaei et al.38 showed that the CHI/BG/HA/halloysite nanotube composite coatings exhibited in-vitro bioactivity upon immersion in SBF38. Arias et al.13 developed CS-CHI/BG coatings and found them to be highly bioactive, corrosion resistant in addition to the suitable adhesion strength and wettability for orthopedic applications. Rehman et al.39 deposited lawsone-loaded BG/CHI on polyetheretherketone/BG layer and reported them to be antibacterial (against staphylococcus carnasous), bioactive, and corrosion resistant.
In this study, a novel polymeric complex of XDA/CS was formed, which is expected to mimic extracellular matrix (provide structural support for osteointegration) and can enhance the adhesion with substrate. BG in the composite coatings is expected to induce apatite-like crystals and stem cell differentiation while HA was supposed to enhance osteoinduction rate. Lawsone was introduced in the coating to prevent biofilm formation. Thus, the proposed composite coatings system can induce antibacterial, bioactive, corrosion resistant, and biocompatible properties for orthopedic implant devices. Herein, we used the XDA and CS (polymeric complex) as a matrix to load bioceramics and herbs, which was not used earlier. HA/BG/Henna-loaded XDA/CS coatings were deposited on 316L SS implants. The deposited coatings presented suitable mechanical, electrochemical, and biological properties for the potential coatings to be employed on orthopedic implants.
Materials and methods
Materials
Xanthan (Xn), Sodium meta periodate (SMP, > 99%), Chondroitin Sulphate (CS) sodium salt from shark cartilage, sodium metasilicate (Na2SiO3·9H2O, 98% pure), calcium nitrate tetrahydrate (Ca (NO3)2·4H2O, 99% pure), citric acid (C6H8O7, 98% pure), sodium nitrate (NaNO3, 99% pure), phosphoric acid (H3PO4, 99.9% pure), sulphuric acid (H2SO4, 99.9% pure), Ethylene glycol (EG, > 99% pure), Ethanol (Molecular weight 46.07 g/mol, 99% pure), Acetic Acid (AA, Glacial 100% pure), and Hydroxyapatite (HA) powder were used as received from Sigma-Aldrich Chemie (Sigma Aldrich, Steinheim Germany). Henna was purchased from Saeed Ghani (SG).
Sample preparation
The 316L SS strips were cut into the rectangular (length—3 cm, width—2 cm, thickness—0.1 cm) and disc shaped (diameter—10 mm, thickness—1 mm) samples using meta cut (METKON302). The disc shape samples were used for antibacterial studies. Afterward, the samples were cleaned and, abrasive silicon carbide papers (having different grit sizes: 120, 240, 360, 400, 800) were used to polish the said samples (120, 240, 360, 400, 800). The bi-distilled water was drawn over the sample`s surface to wash out the impurities/debris. The polished surface of the sample was etched out using 70% H2SO4 and 30% H3PO4 for 25 s followed by rinsing in bi-distilled water40,41,42.
Suspension preparation
Synthesis of Xanthan dialdehyde (XDA)
XDA was synthesized by the oxidation of Xanthan Gum (XG) with SMP in a dark controlled environment at 60 °C and stirred for 4—6 h43. Guo et al.43 and Ngwabebhoh et al.10 outlined the mechanism of XDA formation by using 9.6 W/V% (0.096 g/mL) SMP solution. 9.6 W/V% SMP solution concentration for approximately 45% aldehyde content for XDA was reported to have the highest tensile properties. Using ratio stoichiometry, 0.5 W/V% XG required 0.096 g/mL SMP for 45% XDA content (a similar approach was employed in43). A portion of 0.125 g of Xn was liquified in distilled water (25 mL) at 60 °C (0.5 W/V% XG). The SMP solution was made using 0.96 g (9.6 W/V%) of SMP in 10 mL of distilled water. Later, XG was oxidized by SMP at the concentration of 0.096 g/mL. The solution was stirred for 4–6 h in a dark environment, following41. The reaction was then quenched using 240µL EG, following10.
Preparation of 45S5 bioglass (BG)
BG of composition: P2O5 6%, CaO 24.5%, Na2O 24.5%, SiO2 45% (mol%) was synthesized by first dissolving diatom biosilica (prepared following44) in 35% C6H8O7 solution. The mixture was magnetically stirred for 2 h under 120 °C. Following the complete dissolution of diatom biosilica, H3PO4 was added and magnetically stirred for 45 min. Thereafter, NaNO3, was added followed by the addition of Ca (NO3)2·4H2O which again was stirred for an hour. The attained gel was treated following the procedure executed in45. It was then placed in a muffle furnace (Muffle furnace LMF-E21 manufactured by Labtron) at a constant temperature increment and abatement of 10 °C/min. For 2 h, gel was kept at 700 °C followed by sintering for 3 h at 950 °C. The procedure adopted was similar to Adams et al.44.
Final preparation of suspension
First, BG (0.125 g) was added in XDA solution (0.5 w/v%) and continuously stirred for 6–7 h at 25 °C to disperse the BG particles. Next, 0.25 g of CS was added to the 25 mL of ethanol (1 w/v%). Later, 0.125 g of HA was added and stirred for 2–3 h at 80–100 °C and sonicated for 2.5 h46. In addition, 0.3 g of henna was dissolved in 15 ml of ethanol (2 w/v%)47 and the solution was filtered using filter paper. The filtered 10 mL lawsone solution was then added to 25 mL of HA/CS solution (5:2) as shown in Fig. 1, and subsequently stirred for 30 min at 60 °C.
The final suspension for EPD was prepared by using HA/CS/lawsone solution, and XDA/BG solution (an overview is presented in Fig. 1). XDA/BG and HA/CS/lawsone solutions (1:1) were mixed and magnetically stirred at room temperature. The pH of the resulting XDA/CS/BG/HA/lawsone suspension was maintained at ~ 4.5 using AA.
Electrophoretic deposition
A 316L SS was used as substrate (cathode) and counter-electrode (anode). The anode–cathode distance was 10 mm. The coating thickness and the control over surface crack were optimized by tuning the applied deposition voltage and the deposition time given during the EPD process. The voltage was increased in 5 V increments, from 5 to 25 V. A series of experiments were conducted through a trial–error approach (the deposition time and deposition voltage were varied) which yielded the optimal coatings (crack-free and uniform). A continuous voltage of 20 V was applied for 10 min in that particular context as described in Table 1 and Fig. 2. Similar EPD parameters were used in48,49 to optimize CHI-based composite coatings.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Characterization of XDA/CS/BG/HA/lawsone coatings
Morphological properties
HA/BG/lawsone loaded XDA/CS coatings were investigated optically to check the optimal deposition. By varying time of deposition and voltage applied the variation in levels/thickness of deposition was also investigated. The facet morphology, topography, and thickness of coatings on 316L SS were examined by field emission scanning electron microscopy (FESEM, MIRA, TESCAN). Coated samples of 3 cm × 2 cm × 0.1 cm (rectangular) were examined at various magnifications after being fixed to SEM stubs. To prevent charging effect, the samples were sputtered with Au (Q150/S by Quorum Technologies) before FESEM analysis.
Adhesion test
A tape test was used to gauge the composite coating's (n = 5) adherence strength to the substrate. According to ISO 2409 and ASTM D3359-17 standards, a crosshatch adhesion test was performed. The CC2000 basic cross hatch cutter was used to create scratches on the coated substrates. The adhesive tape was applied for 90 s on the substrate and removed afterwards maintaining an angle of ~ 180° between the hand and the coated surface. The quality of the adhesive strength was then assessed by comparing the scratches to ASTM Standards50,51,52. The ASTM D3363-20 standard was followed to conduct the pencil scratch hardness test (n = 5), following53. Standard holders with grades ranging from 8B (soft) to 2H (hard) pencils were moved over the coated substrate at an angle of 45°. The test continued until the pencil could no longer starch the covered substrate. Following the ASTM B571-97 standard, the adhesiveness of the said coating was analyzed using the bend test (n = 5). Composite coated samples were bent into a 180° U shape using pilers. Composite coatings were evaluated for their adhesive strength by studying their delamination and deformation capacities. A microscope (Novex, Holland) was used to examine the distorted samples after the bending test54. Scratch tests were conducted on the composite coating samples with Revetest mode (using a CSM Revetest machine). An indenter with a 200 m diameter was used to apply a progressive load (0.5–4 N) to the coated surface for scratch testing. Indenter speed and scratch length were 5.2 mm/min and 5 mm, respectively. The sample was run on eight separate tracks. By measuring acoustic emission (AE) and through optical observations critical loads were identified. The minimal load at which the initial crack begins to appear was denoted as the critical load (LC1) while increase in load lead to the complete delamination and that supremely enhanced load was referred as critical load (LC2)55.
Surface properties
Surface roughness
The coated XDA/CS/BG/HA/Lawsone and uncoated 316L SS samples were characterized in terms of average surface roughness (Ra), maximum profile peak height (Rt), and average maximum profile (Rz) by employing stylus profilometer (TMR 360). Three measurements were taken for each set of samples and the average value with the standard deviation was reported. The microscopic tip stays in contact with the surface and moves horizontally. However, the tip's vertical movement was recorded and enhanced. It was mounted vertically, using a stylus profilometer. As a result, the stylus is positioned above the part to be measured. On the surface of both samples, the stylus moved 5 mm.
Contact angle
Distilled water was used to measure surface wettability. Distilled water droplets of 5 µL were used to quantify the contact angle of the bare 316L SS, XDA coated 316L SS, and XDA/CS/BG/HA/lawsone coated 316L SS substrate. A micropipette was used to drop the droplet on bare 316L SS, XDA coated 316L SS, and XDA/CS/BG/HA/lawsone coated 316L SS. Images were taken after every 5 s for 30 s and analyzed through ImageJ software using drop analysis libraries (LB-ADSA)56,57. Tests were repeated five times, and averaged values were reported along with standard deviations.
Chemical properties
Energy dispersive spectroscopy (EDX) analysis
The EDX (OXFORD) installed with FESEM (MIRA, TESCAN) was employed to access the elemental composition of XDA/CS/BG/HA/lawsone coatings (acceleration voltage was kept at 25 kV).
FTIR
The functional groups in XDA/CS/BG/HA/lawsone coating were evaluated using OMNIC paradigm software of an attenuated total reflection Fourier transformation infrared (ATR-FTIR) spectroscope (Thermofisher Nicolet Summit Pro). The transmittance spectrum was obtained in the region of 4000–400 cm−1 with 4 cm−1 resolution after omitting noise.
Corrosion behavior
The Gamry instrument (Potentiostat/Galvanostat/ZRA, reference 600) evaluated the corrosion resistance of the composite coatings and bare 316L SS. Gamry device contains three electrodes: working electrodes (coated/uncoated substrates), counter electrode (graphite), and reference electrode (Ag/AgCl). SBF was used as an electrolyte at 37 °C. At 2.5 mV/sec scanning rate, potentiodynamic polarization scans were carried out at ± 500 mV potential. Tafel plot corrosion potential was calculated as (Ecorr) and corrosion current density was calculated as (Icorr). During an EIS test, an open circuit potential was used with 10 mV perturbation. Frequencies were kept between 100 kHz and 1 MHz. In each case, with measurements in triplicate58,59.
Biological studies
In-vitro bioactivity studies
The biocompatibility (generally ability to bind or attach bone cells in case of orthopedic implants) of XDA/CS/BG/HA/lawsone coatings was accessed using SBF synthesized by using the procedure outlined by Kokubo et al.60.The composite coatings (1.5 cm × 1.5 cm) were submerged in SBF filled falcon tubes and placed in an shaking incubator (30 rpm) for 1, 7, 14, 21 and 28 days at 37 °C. To simulate physiological conditions, the SBF was replaced every 24 h. After the stated periodic time interval of a week, coated strips were carried out of falcon tubes, rinsed with distilled water and processed for further characterization. SEM and FTIR analyses were conducted on the said samples both before and after immersion in SBF.
Antibacterial studies
The basic qualitative antibacterial efficacy of XDA/CS/BG/HA coated 316L SS (Control) and the XDA/CS/BG/HA/lawsone composite coated sample was investigated using the Kirby–Bauer test. Henna was loaded in two different concentrations 0.01 mg/mL and 0.02 mg/mL as of literature and subsequent coatings were tested61. Nutrient Agar (Oxoid-UK) was used to prepare agar medium, which was then autoclaved at 121 °C for 20 min, subsequently; 20 mL of prepared media was transferred to the sterile petri dishes. Composite coated and XDA/CS/BG/HA 316L SS were exposed to UV light for an hour. 20 µL of S. aureus and E. coli owing optical density (OD600) of 0.015 ± 0.002 was rolled out over solidified agar medium using a sterilized glass slider. Coatings were then placed over the uniformly distributed bacteria in such a way that coated side-faced bacteria, followed by round the clock incubation at 37 °C. Afterward, Pictures were taken, by using ImageJ software the inhibition zone was measured.
Results and discussions
Morphological analysis
The surface topography of the XDA/CS/BG/HA/lawsone composite coating deposited on 316L SS was evaluated using FESEM. SEM micrographs of composite coating at low and high magnification revealed a plain, homogeneous, and all-alike coating with no cracks on the surface, as shown in Fig. 3A, B. Through the decomposition of water into hydrogen and oxygen (O) (electrolysis), that usually occurs during EPD, a limited number of micropores created. The coating exhibited uniform distribution of BG and HA particles (FTIR and EDX verified the existence of HA and BG) in the polymeric matrix due to invariable particle size in final suspension39. The FESEM images show the agglomeration of BG and HA particles (Fig. 3A). The outcome of the current study is like the one revealed by62,63. HA particles are induced and embedded in the polymeric matrix depicting quasi spherical morphologies. The pores present in the polymeric matrix are filled by HA particles and their agglomerates, ultimately intensifying the mechanical stability of the coating. Similar morphologies for HA-based composite coating were proclaimed by Ahmed and Ur Rehman et al.64 and Louvier-Hernández et al.65. The cross-sectional micrographs of XDA/CS/BG/HA/lawsone composite coating authenticates the uniform coating with thickness of ~ 3 μm, as shown in Fig. 3B. Similar coating thicknesses were reported in previous studies66,67.
Adhesion tests
Tape test
Adhesion tests are conducted on composite coating to evaluate their mechanical strength. Samples that underwent tape testing were analyzed using an optical microscope (Novex, Holland) and categorized using a tape test according to ASTM D3359 (Fig. 4). First, we scratched the coated portion of the substrate with a crosshatch cutter, as shown in Fig. 4A. After 90 s, the tape was quickly removed and the image was acquired Fig. 4B. 4B adhesion strength was achieved by the composite coatings (only minor delamination of 5%); this implies that at intersections, small fragments of the coating become dislodged, impacting less than 5% of the surface area, as per the ASTM standards68. Prior studies shows that HA/BG-based composite coatings rated as 3B (approximately 5–15% of the lattice area suffer from small flakes detaching along edges and cuts) shows good adhesion strength but in our case coating adhesion rated as 4B much good adhesion strength than already reported studies. The robust adhesion strength observed in the composite coating can be attributed to the resilient polymeric network formed by XDA and CS, as discussed in “FTIR” section, as well as the presence of HA/BG69. The developed composite coatings presented better adhesion than other reported coatings, that utilized biopolymers as well. M. A. U. Rehman et al.62 conducted the tape test (ASTM D3359-97 and B571-97) on composite coating of CHI/gelatin/Cu-doped-BG on a 316L SS substrate, the coatings were reported to delaminate at the edges. The better adhesion strength of the composite coatings is attributed to the defect-free coatings (microstructure), enhanced cross-linking capability of aldehyde groups in XDA, and etching of the substrate prior to the coatings which may have assisted in the mechanical and chemical linking of the composite coating with the substrate43,70. Thus, the coating was rated as “4B” according to the ASTM standard. Zhang et al.71 observed increased adhesion of coatings, coinciding with the uniform distribution of HA particles, of Bovine-HA deposited on Ti-12Cr substrate. Chen et al.72 utilized EPD to develop Alginate/BG coatings on 316L SS and remarked their adhesive strength to be “3B” according to ASTM D3359-B, after conducting the tape test.
Bend test
An ASTM B57197 bend test was used to assess the bending strength of the composite coating upon bending to 180°. Figure 4C, and D show the images of an optical microscope (Novex, Holland) captured after the bend test. The composite coating exhibited sufficient resistance to bending loads throughout substrates, as no delamination was observed even at the edges of the composite coating. In this study, composite coatings presented better adhesion strength upon bending compared to the62 where CHI-based composite coatings delaminated at the edges. The better adhesion strength of the composite coatings is attributed to the defect-free coatings (microstructure), enhanced cross-linking capability of aldehyde groups in XDA, and etching of the substrate prior to the coatings which may have assisted in the mechanical and chemical linking of the composite coating with the substrate43,70. Thus, the coating was rated as “4B” according to the ASTM standard.
Pencil hardness test
The adhesion strength of the XDA/CS/BG/HA/lawsone coating with the 316L SS was evaluated by the pencil test.
The findings showed the composite coating to be able to withstand a range of pencil hardness values without showing any signs of cracking or flaking till H. However, a slight powder delamination was observed when the coating was scratched with the 2H pencil, as shown in Fig. 4E. Said results are due to the presence of HA/BG69 and strong polymeric network of XDA and CS (discussed in “FTIR” section).
Scratch test
XDA/CS/BG/HA/lawsone composite coating adhesion strength was evaluated with the scratch test shown in Fig. 5. As shown in Fig. 5, XDA/CS/BG/HA/lawsone composite coating experienced a 15 N Lc1 value, and circular cracks appeared on its surface, despite remaining intact. According to the measured value of second critical load (Lc2), at Lc2 there is still no significant delamination of coatings showing that the XDA/CS/BG/HA/lawsone composite coating has better adherence. After the Lc2 composite coatings delaminated from the surface. A scratch test indicated that the composite coatings were suitable for designing coatings for orthopedic implant devices Fig. 573,74.
Surface properties
Wettability
The wettability of the surface was measured by contact angle, as shown in Fig. 6. The optimal contact angle for facilitating initial protein attachment typically falls within the range of (35°–80°)75. The measured values of bare 316L SS, XDA coated 316L SS and composite coating were 64° ± 1°, 56 ± 1° and 48° ± 4°, respectively. The contact angle of XDA coated 316L SS is lower than the bare 316L SS, indicating increased hydrophilic character introduced by the XDA coating. This enhanced hydrophilicity is attributed to XDA`s intrinsic properties, particularly its hydroxyl and aldehyde functional groups76,77.
Furthermore, the composite coating exhibited lowest contact angle signifies the highest-level hydrophilicity in comparison to XDA coated 316L SS and bare 316L SS Substrate, this could be due to the hydrophilic nature of HA, BG (silanol groups led to the hydrophilic nature of BG) and CS78. The presence of Sulfate and carboxylate functional groups in CS and hydroxyl groups in HA makes the composite coatings hydrophilic10. Additionally, XDA also showed a hydrophilic nature due to the introduction of aldehyde groups into the polymer chain, leading to enhanced hydrophilicity77. Chen et al.72 reported the relationship of contact angle and surface roughness, surface roughness increases as contact angle decrease and the reported results are in agreement with72,79. Manzur et al. shows the contact angle of Poly(lactic-co-glycolic) Acid/henna/Copper-doped Mesoporous bioactive glass nanoparticles (PLGA/henna/Cu-MBGNs) is 41° on Mg substrate which agrees with reported studies57. Shi et al.79 also conducted study of hydrophilicity on CHI/HA/GO coating on Ti substrate and reported a contact angle of 53.3 ± 1.3° and reported that enhanced hydrophilicity is desirable to facilitate the adhesion of cells and cell-adhesive proteins, promoting osteoconductivity.
Surface roughness test
Surface topography plays a significant role in influencing the cellular interaction with induced biomedical implants. Related cells and proteins should be able to adhere to the implant surface49,80. Surface topography was investigated by measuring the average surface roughness (Ra), maximum profile peak height (Rt), average maximum profile (Rz) of the XDA/CS/BG/HA/lawsone composite coatings deposited on 316L SS via EPD, as given in Table 2. The composite coatings exhibited relatively higher values of Ra, Rz, and Rt. The composite coatings exhibited the Rz values of 1.78 µm, which can allow the osteoblast cells to attach to the coated surface81,82 owe to the favorable surface topography. Osteoblast attachment and proliferation can be influenced by other factors than just surface topography. These factors include wettability and surface chemistry, which should also be considered. This study found that composite coatings had suitable wettability, roughness, and surface chemistry for protein attachment and later cell attachment and proliferation. To achieve optimal tissue integration, the growth and differentiation of the relevant cells are important (in the current case osteoblast cells)83,84.
Chemical properties
EDX analysis
EDX analysis indicated the presence elements attributed to the biopolymers (XDA/CS), bioceramics (HA/BG) and lawsone. The peaks of O and Carbon (C) may denote the subsistence of CS and XDA in the composite coatings, as shown in Fig. 7. Although, it is not accurate to spot the C and O via EDX. Therefore, to verify the subsistence of XDA and CS in the composite coatings, FTIR was executed. Additionally, the occurrence of HA in the coating was verified by the identification of peak spots, associated with P and Ca. Furthermore, the area EDX analysis portrayed Mg, Si and P indicating the presence of BG in the composite coatings. Although, the Ca and P are present in HA and BG. The appearance of Si is associated with the presence of BG in composite coating.
FTIR analysis of composite coatings
The identification of the aldehyde groups in XDA can be confirmed by FTIR spectroscopy. The region of 1730–1750 cm−1 shows an evident peak which identify the aldehyde group in XDA70. In addition, the peak in the region of 1600–1650 cm−1 associated to the C=C stretching vibration and peak at 2978 cm−1 is associated with C–H stretching vibrations, respectively10. Moreover, the band of O–H stretching vibrations appeared in the range of 3200–3600 cm−1. The peaks in the region of 1050–1100 cm−1 correspond to C–O–C stretching vibrations10.
In FTIR spectra of CS, the peaks in between 3000–3600 cm−1 represent –NH and –OH stretching vibrations. The broad peak appeared at 2907 cm−1 correspond to the C–H bond13. The sulfate region of CS can typically be found between 1000 and 1300 cm−1 as shown in Fig. 8A. This region indicated the presence of a strong peak at 1236 cm−1, attributed to the disproportioned and uneven stretching vibrations of the sulfate groups (S–O bond))85. The peak at ~ 1039 cm−1 can also be observed, which corresponded to the symmetric stretching vibration of the sulfate groups (C–O–S ring))85. The amide region of CS was found between 1700 and 1500 cm−1. The peak at 1606 cm−1 introduced due to the amide I vibration of the peptide backbone86, similarly peak at around 1560 cm−1 was introduced due to the amide II vibration of the peptide backbone85,87. FTIR spectra of bioactive glasses showed Si–O–Si stretching vibration, at ∼703 cm−1and 468 cm−1 and Si–O stretching of nonbridging oxygen atom at ∼925 cm−188,89. This peak is manifesting the SiO2 network structure in BG, which is critical for its bioactivity. The phosphate peak (PO4−3) appeared at ∼610 cm−189.
The peak at ~ 910 cm−1 in HA, is accredited to the stretching vibration of phosphate (PO4−3) groups in HA. An extensive band in the range of 500–600 cm−1, depicted bending vibration of phosphate (PO−3) groups in HA90. A weak peak at around 738 cm−1, corresponded to the deformation vibration of carbonate (CO3−2) groups in HA as shown in Fig. 8B. Moreover, a solid peak for carbonate (CO3−2) appeared at 1454 cm−190,91. The infrared spectra of lawsone with transmittance peaks showed at ∼3320 cm−1 indicating an O − H bond92. The peak spot at about 1755 cm−1 denotes the carbonyl group (C=O), while the aliphatic C–H stretching peaks associated with ∼2925 cm−1. The phenolic groups in henna were evident by the climax at ∼1000 cm−193.
The FTIR spectra of composite coating showed the genesis of Schiff base between XDA and CS86. XDA exhibited characteristic peaks of the aldehyde group (C=O) at around 1730–1740 cm−1. However, the amine group (N–H) in CS appeared at around 3300–3400 cm−1. After the crosslinking reaction, a new peak corresponding to the imine group (–C=N–) in the Schiff base appears at a typical range of 1620–1660 cm−194 This shift in the peak position from the aldehyde and amine groups to the imine group can serve as an indicator for the formation of the Schiff base between XDA and CS. The -OH band existed in the final composite coating showing the presence of henna and XDA. The overlapping peaks at 1022 cm-1 is attributed to phosphate group of HA and phenolic group of henna90,93. However, the peak of dispersed BG in the composite coating appeared at 703 cm−1 corresponded to Si–O–Si stretching vibrations95. The phosphate group peak due to HA appeared at 533 cm−186.
Corrosion behavior
Potentiodynamic polarization
The potentiodynamic polarization behavior of bare and XDA/CS/BG/HA/lawsone coated 316L SS in SBF is represented in Fig. 9. The values of Ecorr and icorr were determined using the Tafel method. From Fig. 9 the composite coated 316L SS shows the cathodic slope is lower as compared to the bare 316 L SS. Similarly, the anodic slope of the composite coated 316L SS is suppressed by three orders of the magnitude and have a good agreement with the cathodic slope. The composite coated 316L SS shows reduced corrosion current density (iCorr) and higher corrosion potential (Ecorr) than bare 316L SS. The polarization resistance (Rp) of the XDA/CS/BG/HA/lawsone coated 316L is increased in two ordered of the magnitude than bare 316L SS. This indicates that the composite coating provides the significant corrosion resistance to 316L SS in SBF solution13,96,97.
Electrochemical impedance spectroscopy (EIS)
The plot of the EIS of uncoated 316L SS compared to XDA/CS/BG/HA/lawsone coated 316L SS is shown in Fig. 10A. The Nyquist plots of the bare and coated samples present a high semi-capacitive arc. It indicates that the same process of corrosion is occuring at a lower rate for the coated substrate47. Figure 10B shows the impedance values are almost equal at low frequencies (úZê0.01 Hz), but at higher frequency, coated 316L SS has higher impedance values—dispensing information about the electrode/solution interface. Bode phase plot shows coated 316L SS exhibits an increased capacitive response over the broad frequency range with a lesser phase angle than bare 316L SS59,98.
Figure 10C, D shows that the electric equivalent circuits (EEC) Rs(Q1(R1(Q2R2))) and Rs(Q1(R1(Q2(R2W))) indicates the electrochemical activity between uncoated and coated 316L SS. Rs(Q1(R1(Q2(R2W)))) is the preferred choice for coated 316L SS. According to the reported data, numerous interpretations have been provided for the circuit components99. Specifically, Q1 and R1 represent the porous layer capacitance and resistance, while Q2 and R2 show the barrier layer resistance when connected (series) with a Warburg diffusion element (W). The term Rs represents solution resistance. As shown in Fig. 10A, certain diffusin in Nyquist plot introduced the Warburg diffusion component.
Table 3 shows that the R1 porous layer has a higher corrosion resistance than R2, thus BG/HA/lawsone contributed more to corrosion resistance than R2 resistance. Potucek et al.100 indicated the solution chosen has significant impact on the resistance R values generated from the EIS data, while the capacitance (C) values can be used to accurately determine the electrochemical properties associated with the solution selected, irrespective of the solution condition. Equation 1 allows us to calculate the different elements`s equivalent capacitance values in Fig. 10C, D by combining values (Q and n) with their respective resistances.
Biological studies
In-vitro SBF studies
The XDA/CS/BG/HA/lawsone composite coating was immersed in SBF to track the possible changes in the morphology and the formation of the apatite-like layer on the surface of the coatings. It is widely accepted that the genesis of apatite-like layer indicates the osteoinduction and osteointegration of the designed implants84. The HA layer formation was confirmed via FTIR, SEM, EDX and X-ray diffraction (XRD). Dissolution of the BG particles results in the release and diffusion of Ca and P ions, the ionic exchange that then happens assists in the formation of apatite-like structure on the surface of the coatings (Fig. 11A, B)20,21,101. The dissolution of BG was evident by the decrease of the intensity of silica peaks in the FTIR spectra (the reduction in silica peak may also be credited to the initiation of the HA layer after being dipped in SBF). The magnitude of the silica peaks reduces with the increase in immersion time whereas the intensity of phosphate bands increases (Fig. 11C). After 28 days of immersion in SBF, the FTIR spectra faded away BG-associated Si–O–Si elongated peaks102. The bioactive glass peaks were formed at 460 and 703 cm−1 in pure composite coating and after immersion in SBF till 21 days, as shown in (Fig. 11C). The carbonate (CO3−2) and phosphate (PO4−3) peaks attributed to HA formation in SBF were observed after 28 days. The slightly shifted and intensified carbonate peaks appeared at 680 and 1415 cm−1. Moreover, broad, and more intense peaks of phosphate group appeared at 550 and 980 cm−1. Agathopoulos et al.102 also reported the appearance of HA layer associated peaks in FTIR after immersion in SBF. The reported results are in agreement with103,104.
The possible mechanism for the formation of HA crystals upon dipping in SBF is attributed to the release of Ca and P ions from the composite coatings, which then react with the SBF ultimately devising a concentrated solution of Ca Phosphate. Thus, resulting in the formation of HA crystals on the surface of the coating through nucleation and growth105. The HA layer formation on composite coating after immersion in SBF for 28 days was first validated by FTIR followed by SEM analysis.
HA layer formation on BG coatings was also confirmed using FESEM after immersion in SBF, as shown in (Fig. 11A, B). The XDA/CS/BG/HA/lawsone coatings are designed to create a bioactive layer on implant surfaces (to induce mineralization), which is crucial for successful osteointegration106. FESEM analysis showed the appearance of typical spherical or needle-shaped morphology.
XRD was utilized to examine XDA/CS/BG/HA/lawsone coatings immersed in SBF for 28 days to verify the existence of a HA layer, as depicted in Fig. 11D. The results of the XRD analysis unequivocally substantiated the formation of a HA layer before immersion in SBF due to the presence of HA in the developed coatings. The increase in the intensities of HA associated peaks after immersion in SBF for 28 days confirmed the formation of HA layer due to BG in coating107. The XRD pattern exhibited a peak corresponding to HA at angles of 25.8° and 31.5°108,109.
EDX analysis after 28 days of immersion in SBF showed the peaks of Ca and P while Si peak vanished (agrees with FTIR analysis). The Ca/P ratio calculated from the EDX analysis before and after immersion in SBF was 0.544 and 1.54, respectively as shown in Fig. 11E, F. Ca/P ratio of 1.54 after immersion in SBF is very close to the stoichiometric ratio of the HA101. The results agree with110,111
Antibacterial studies
Significant antimicrobial effects of composite coatings were seen because of lawsone and naphthoquinone release. Figure 12A shows that XDA/CS/BG/HA coated 316L SS did not form any zone of inhibition, while 0.01 mg/mL and 0.02 mg/mL lawsone loaded composite coated samples showed the zones of 13.32 mm ± 0.5 mm and 21.65 mm ± 0.5 mm against E. coli, respectively. While Fig. 12B shows that XDA/CS/BG/HA 316L SS couldn’t show any bacteriostatic or bactericidal properties while 0.01 mg/mL and 0.02 mg/mL lawsone loaded composite coated samples exhibited zones of 16.48 mm ± 0.5 mm and 21.04 mm ± 0.5 mm against S. aureus, respectively. The clear zone of inhibition portrayed that 0.02 mg/mL of lawsone was enough to create strong antibacterial effect. Lawsone (2-hydroxy-1,4-naphthoquinone) the major component of henna, generates reactive oxygen species (ROS) and shows to apoptotic cell death of bacteria112. The results are consistent with those reported by Rubiay et al.113.
Novel and functional bio-composite coating development has been a success. Apatite induction was confirmed through in-vitro SBF studies, while antibacterial potential due to the release of lawsone was established and evaluated through Kirby–Bauer test against E. coli and S. aureus. Corrosion resistance of 316L SS was enhanced by first order of magnitude, examined via Potentiodynamic polarization scan and EIS analysis. The composite coatings developed in the current study showed the strong potential to coat orthopedic implant devices. The composite coatings can provide bone regeneration and can prevent biofilm formations. The future studies will involve cell biology, biomarkers quantification, alkaline phosphate activity, drug release kinetics, quantitative microbiology studies and in-vivo studies. It is expected that the designed coatings will help in the differentiation and proliferation of the osteoblast cells which will eventually help in the growth of bone tissues. The biochemical process aided through XDA/CS/BG/HA lawsone is proposed to overcome the challenges associated with orthopedic implants, as shown in Fig. 13.
Conclusions
The XDA/CS crosslinking in the polymeric network was confirmed by FTIR analysis, resulting in the formation of a robust coating of XDA/CS/BG/HA/lawsone (coating thickness ~ 3 µm) using EPD. The results of the pencil hardness test, tape test, scratch test, and bend test confirmed suitable adhesion strength of the composite coating with the 316L SS substrate. The bioactivity and antibacterial tests, combined with the potentiodynamic polarization assessment, demonstrated that the 316L SS coated with XDA/CS/BG/HA/lawsone exhibited promising characteristics for the development of orthopedic implants. The coated substrate showed significant corrosion resistance, as well as apatite induction and antibacterial potential, making it a highly attractive prospect for further investigations and eventually the translation to the clinic. Overall, the results suggested that the fabricated coated implant has the potential to be considered to design orthopedic implant devices (Table 4).
Data availability
The datasets used and analyzed during the current study are available from the corresponding author upon reasonable request.
References
Total Knee Replacement—OrthoInfo—AAOS. https://orthoinfo.aaos.org/en/treatment/total-knee-replacement. Accessed 25 Dec 2022.
Global Orthopedic Implant Market Garnered USD 47 Billion in. https://www.globenewswire.com/en/news-release/2022/07/25/2484984/0/en/Global-Orthopedic-Implant-Market-Garnered-USD-47-Billion-in-2021-and-is-Expected-to-Grow-with-a-CAGR-of-7-During-2022-2031-Market-to-Grow-on-Back-of-Rising-Number-of-Geriatric-Peop.html. Accessed 25 Dec 2022.
Wallace, I. J. et al. Knee osteoarthritis has doubled in prevalence since the mid-20th century. Proc. Natl. Acad. Sci. U. S. A. 114(35), 9332–9336. https://doi.org/10.1073/PNAS.1703856114 (2017).
Nazzal, A. et al. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: An experimental rabbit study. J. Hand Surg. Am. 31(7), 1123–1130. https://doi.org/10.1016/J.JHSA.2006.03.001 (2006).
Panje, W. R. & Hetherington, H. E. Use of stainless steel implants in facial bone reconstruction. Otolaryngol. Clin. N. Am. 28(2), 341–349. https://doi.org/10.1016/S0030-6665(20)30548-X (1995).
Talha, M., Behera, C. K. & Sinha, O. P. A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications. Mater. Sci. Eng.: C 33(7), 3563–3575. https://doi.org/10.1016/J.MSEC.2013.06.002 (2013).
Sridhar, T. M., Kamachi Mudali, U. & Subbaiyan, M. Preparation and characterisation of electrophoretically deposited hydroxyapatite coatings on type 316L stainless steel. Corros. Sci. 45(2), 237–252. https://doi.org/10.1016/S0010-938X(02)00091-4 (2003).
Balla, V. K., Das, M., Bose, S., Janaki Ram, G. D. & Manna, I. Laser surface modification of 316 L stainless steel with bioactive hydroxyapatite. Mater. Sci. Eng.: C 33(8), 4594–4598. https://doi.org/10.1016/J.MSEC.2013.07.015 (2013).
Patel, J., Maji, B., Moorthy, N. S. H. N. & Maiti, S. Xanthan gum derivatives: Review of synthesis, properties and diverse applications. RSC Adv. 10(45), 27103–27136. https://doi.org/10.1039/D0RA04366D (2020).
Ngwabebhoh, F. A. et al. Self-crosslinked chitosan/dialdehyde xanthan gum blended hypromellose hydrogel for the controlled delivery of ampicillin, minocycline and rifampicin. Int. J. Biol. Macromol. 167, 1468–1478. https://doi.org/10.1016/J.IJBIOMAC.2020.11.100 (2021).
Ge, L. et al. Development and characterization of dialdehyde xanthan gum crosslinked gelatin based edible films incorporated with amino-functionalized montmorillonite. Food Hydrocoll. 51, 129–135. https://doi.org/10.1016/J.FOODHYD.2015.04.029 (2015).
Rammelt, S. et al. Coating of titanium implants with collagen, RGD peptide and chondroitin sulfate. Biomaterials 27(32), 5561–5571. https://doi.org/10.1016/J.BIOMATERIALS.2006.06.034 (2006).
Cordero-Arias, L. & Boccaccini, A. R. Electrophoretic deposition of chondroitin sulfate-chitosan/bioactive glass composite coatings with multilayer design. Surf. Coat. Technol. 315, 417–425. https://doi.org/10.1016/J.SURFCOAT.2017.02.037 (2017).
Stadlinger, B. et al. Evaluation of osseointegration of dental implants coated with collagen, chondroitin sulphate and BMP-4: An animal study. Int. J. Oral Maxillofac. Surg. 37(1), 54–59. https://doi.org/10.1016/J.IJOM.2007.05.024 (2008).
Burger, M., Sherman, B. S. & Sobel, A. E. Observations of the influence of chondroitin sulphate on the rate of bone repair. J. Bone Jt. Surg. 44, 675–687 (1962).
Schneiders, W. et al. Effect of chondroitin sulphate on material properties and bone remodelling around hydroxyapatite/collagen composites. J. Biomed. Mater. Res. A 85A(3), 638–645. https://doi.org/10.1002/JBM.A.31611 (2008).
Nijsure, M. P., Pastakia, M., Spano, J., Fenn, M. B. & Kishore, V. Bioglass incorporation improves mechanical properties and enhances cell-mediated mineralization on electrochemically aligned collagen threads. J. Biomed. Mater. Res. Part A 105, 2429–2440. https://doi.org/10.1002/jbm.a.36102 (2017).
Leonor, I. B., Rodrigues, A. I. & Reis, R. L. Designing biomaterials based on biomineralization for bone repair and regeneration. Biominer. Biomater.: Fundam. Appl. https://doi.org/10.1016/B978-1-78242-338-6.00014-4 (2016).
Meng, D., Ioannou, J. & Boccaccini, A. R. Bioglass®-based scaffolds with carbon nanotube coating for bone tissue engineering. J. Mater. Sci. Mater. Med. 20(10), 2139–2144. https://doi.org/10.1007/S10856-009-3770-9/FIGURES/6 (2009).
Zheng, K. et al. Toward highly dispersed mesoporous bioactive glass nanoparticles with high cu concentration using cu/ascorbic acid complex as precursor. Front. Chem. 7, 459480. https://doi.org/10.3389/FCHEM.2019.00497/BIBTEX (2019).
Baino, F. & Yamaguchi, S. The use of simulated body fluid (SBF) for assessing materials bioactivity in the context of tissue engineering: Review and challenges. Biomimetics 5(4), 1–19. https://doi.org/10.3390/BIOMIMETICS5040057 (2020).
Yuan, Y. et al. Osteogenesis stimulation by copper-containing 316L stainless steel via activation of akt cell signaling pathway and Runx2 upregulation. J. Mater. Sci. Technol. 35(11), 2727–2733. https://doi.org/10.1016/J.JMST.2019.04.028 (2019).
Hydroxyapatite—Properties and Applications. https://www.azom.com/article.aspx?ArticleID=107. Accessed 26 Dec 2022.
Legeros, R. Z. & Legeros, J. P. Hydroxyapatite. Bioceram. Clin. Appl. https://doi.org/10.1533/9781845694227.2.367 (2008).
Parham, S. et al. Antioxidant, antimicrobial and antiviral properties of herbal materials. Antioxidants 9(12), 1–36. https://doi.org/10.3390/ANTIOX9121309 (2020).
Al-Rubiay, K. K., Jaber, N. N., Bh, A. M. & Alrubaiy, L. K. Antimicrobial efficacy of henna extracts. Oman Med. J. 23(4), 253 (2008).
Dinesh Babu, P. & Subhasree, R. S. Antimicrobial activities of Lawsonia inermis—A review. Acad. J. Plant Sci. 2(4), 231–232 (2009).
Nigussie, D., Davey, G., Legesse, B. A., Fekadu, A. & Makonnen, E. Antibacterial activity of methanol extracts of the leaves of three medicinal plants against selected bacteria isolated from wounds of lymphoedema patients. BMC Complement Med Ther https://doi.org/10.1186/S12906-020-03183-0 (2021).
Grill, M. F. & Maganti, R. K. Neurotoxic effects associated with antibiotic use: management considerations. Br. J. Clin. Pharmacol. 72(3), 381–393. https://doi.org/10.1111/J.1365-2125.2011.03991.X (2011).
Sankara Narayanan, T. S. N., Park, I. S. & Lee, M. H. Surface modification of magnesium and its alloys for biomedical applications: Opportunities and challenges. Surf. Modif. Magn. Alloys Biomed. Appl. 1, 29–87. https://doi.org/10.1016/B978-1-78242-077-4.00002-4 (2015).
Chang, J. & Zhou, Y. L. Surface modification of bioactive glasses. Bioact. Glass. https://doi.org/10.1016/B978-0-08-100936-9.00008-3 (2018).
Fox, K. E., Tran, N. L., Nguyen, T. A., Nguyen, T. T. & Tran, P. A. Surface modification of medical devices at nanoscale—Recent development and translational perspectives. Biomater. Transl. Med.: Biomater. Approach https://doi.org/10.1016/B978-0-12-813477-1.00008-6 (2019).
Avcu, E. et al. Electrophoretic deposition of chitosan-based composite coatings for biomedical applications: A review. Prog. Mater. Sci. 103, 69–108. https://doi.org/10.1016/J.PMATSCI.2019.01.001 (2019).
Moyer, K. et al. Electrophoretic deposition of LiFePO4 onto 3-D current collectors for high areal loading battery cathodes. Mater. Sci. Eng.: B 241, 42–47. https://doi.org/10.1016/J.MSEB.2019.02.003 (2019).
Nieto, M. I., Santacruz, I. & Moreno, R. Shaping of dense advanced ceramics and coatings by gelation of polysaccharides. Adv. Eng. Mater. 16(6), 637–654. https://doi.org/10.1002/ADEM.201400076 (2014).
Tiwari, S. K. et al. Development and characterization of sol–gel silica–alumina composite coatings on AISI 316L for implant applications. Surf. Coat. Technol. 201(16–17), 7582–7588. https://doi.org/10.1016/J.SURFCOAT.2007.02.026 (2007).
Bombaldi de Souza, R. F. et al. Phosphorylation of chitosan to improve osteoinduction of chitosan/xanthan-based scaffolds for periosteal tissue engineering. Int. J. Biol. Macromol. 143, 619–632. https://doi.org/10.1016/J.IJBIOMAC.2019.12.004 (2020).
Molaei, A. & Yousefpour, M. A. Electrophoretic deposition of chitosan–bioglass®–hydroxyapatite–halloysite nanotube composite coating. Rare Metals 41(11), 3850–3857. https://doi.org/10.1007/S12598-018-1021-2/FIGURES/8 (2022).
Ur Rehman, M. A. et al. Electrophoretic deposition of lawsone loaded bioactive glass (BG)/chitosan composite on polyetheretherketone (PEEK)/BG layers as antibacterial and bioactive coating. J. Biomed. Mater. Res. A 106(12), 3111–3122. https://doi.org/10.1002/JBM.A.36506 (2018).
Logesh, M., Marimuthu, A., Ferreira, J. M. F., Ramakrishnan, P. & Ballamurugan, A. M. Evaluation of the protective nature of GO–BCP nanocomposite coatings on 316L SS in artificial body fluid. J. Am. Ceram. Soc. 106(6), 3843–3852. https://doi.org/10.1111/JACE.18975 (2023).
Assadian, M., Jafari, H., GhaffariShahri, S. M., Idris, M. H. & Gholampour, B. Corrosion resistance of EPD nanohydroxyapatite coated 316L stainless steel. Surf. Eng. 30(11), 806–813. https://doi.org/10.1179/1743294414Y.0000000330 (2014).
Prabakaran, K. & Rajeswari, S. Electrochemical, SEM and XPS investigations on phosphoric acid treated surgical grade type 316L SS for biomedical applications. J. Appl. Electrochem. 39(6), 887–897. https://doi.org/10.1007/S10800-008-9738-5/FIGURES/6 (2009).
Guo, J., Ge, L., Li, X., Mu, C. & Li, D. Periodate oxidation of xanthan gum and its crosslinking effects on gelatin-based edible films. Food Hydrocoll. 39, 243–250. https://doi.org/10.1016/J.FOODHYD.2014.01.026 (2014).
Adams, L. A., Essien, E. R., Adesalu, A. T. & Julius, M. L. Bioactive glass 45S5 from diatom biosilica. J. Sci.: Adv.Mater. Devices 2(4), 476–482. https://doi.org/10.1016/J.JSAMD.2017.09.002 (2017).
Essien, E. R., Adams, L. A. & Igbari, F. O. Mechanical properties and in vitro physico-chemical reactivity of gel-derived SiO2–Na2O–CaO–P2O5 glass from sand. J. Chin. Chem. Soc. 63(7), 618–626. https://doi.org/10.1002/JCCS.201500496 (2016).
Drevet, R. et al. Electrophoretic deposition (EPD) of nano-hydroxyapatite coatings with improved mechanical properties on prosthetic Ti6Al4V substrates. Surf. Coat. Technol. 301, 94–99. https://doi.org/10.1016/J.SURFCOAT.2015.12.058 (2016).
Rahmoun, N. M. et al. Antibacterial and antifungal activity of lawsone and novel naphthoquinone derivatives. Med. Mal. Infect. 42(6), 270–275. https://doi.org/10.1016/J.MEDMAL.2012.05.002 (2012).
Singh, S., Singh, G. & Bala, N. Corrosion behavior and characterization of HA/Fe3O4/CS composite coatings on AZ91 Mg alloy by electrophoretic deposition. Mater. Chem. Phys. 237, 121884. https://doi.org/10.1016/J.MATCHEMPHYS.2019.121884 (2019).
Ahmad, K. et al. Electrophoretic deposition, microstructure and selected properties of zein/cloves coatings on 316L stainless steel. Prog. Org. Coat. 176, 107407. https://doi.org/10.1016/J.PORGCOAT.2023.107407 (2023).
Lakshmi, R. V. & Basu, B. J. Fabrication of superhydrophobic sol–gel composite films using hydrophobically modified colloidal zinc hydroxide. J. Colloid Interface Sci. 339(2), 454–460. https://doi.org/10.1016/J.JCIS.2009.07.064 (2009).
Cross Hatch Adhesion Testers | Adhesion Testing | UK Dyne Testing. https://dynetesting.com/cross-hatch-adhesion-testing/. Accessed 07 Mar 2023.
ASTM D3359 Test Methods for Measuring Adhesion by Tape—Micom. https://www.micomlab.com/micom-testing/astm-d3359/. Accessed 07 Mar 2023.
Standard Test Method for Film Hardness by Pencil Test. https://www.astm.org/d3363-22.html. Accessed 07 Mar 2023.
Standard Practice for Qualitative Adhesion Testing of Metallic Coatings. https://www.astm.org/b0571-18.html. Accessed 07 Mar 2023.
Ur Rehman, M. A. et al. Antibacterial and bioactive coatings based on radio frequency co-sputtering of silver nanocluster-silica coatings on PEEK/bioactive glass layers obtained by electrophoretic deposition. ACS Appl. Mater. Interfaces 9(38), 32489–32497. https://doi.org/10.1021/ACSAMI.7B08646 (2017).
Ryan, B. J. & Poduska, K. M. Roughness effects on contact angle measurements. Am. J. Phys. 76(11), 1074–1077. https://doi.org/10.1119/1.2952446 (2008).
Manzur, J. et al. Electrophoretic deposition, microstructure, and selected properties of poly(lactic- co-glycolic) acid-based antibacterial coatings on Mg substrate. ACS Omega 8(20), 18074–18089. https://doi.org/10.1021/ACSOMEGA.3C01384/SUPPL_FILE/AO3C01384_SI_001.ZIP (2023).
Batool, S. A., Ahmad, K., Irfan, M. & UrRehman, M. A. Zn–Mn-doped mesoporous bioactive glass nanoparticle-loaded zein coatings for bioactive and antibacterial orthopedic implants. J. Funct. Biomater. 13(3), 97. https://doi.org/10.3390/JFB13030097 (2022).
Katta, P. P. K. & Nalliyan, R. Corrosion resistance with self-healing behavior and biocompatibility of Ce incorporated niobium oxide coated 316L SS for orthopedic applications. Surf. Coat. Technol. 375, 715–726. https://doi.org/10.1016/J.SURFCOAT.2019.07.042 (2019).
Kokubo, T. & Takadama, H. How useful is SBF in predicting in vivo bone bioactivity?. Biomaterials 27(15), 2907–2915. https://doi.org/10.1016/J.BIOMATERIALS.2006.01.017 (2006).
Motalebi, A., Nasr-Esfahani, M., Ali, R. & Pourriahi, M. Improvement of corrosion performance of 316L stainless steel via PVTMS/henna thin film. Prog. Nat. Sci.: Mater. Int. 22(5), 392–400. https://doi.org/10.1016/J.PNSC.2012.10.006 (2012).
Rehman, M. A. U., Munawar, M. A., Schubert, D. W. & Boccaccini, A. R. Electrophoretic deposition of chitosan/gelatin/bioactive glass composite coatings on 316L stainless steel: A design of experiment study. Surf. Coat. Technol. 358, 976–986. https://doi.org/10.1016/J.SURFCOAT.2018.12.013 (2019).
Pishbin, F., Simchi, A., Ryan, M. P. & Boccaccini, A. R. Electrophoretic deposition of chitosan/45S5 Bioglass® composite coatings for orthopaedic applications. Surf. Coat. Technol. 205(23–24), 5260–5268. https://doi.org/10.1016/J.SURFCOAT.2011.05.026 (2011).
Ahmed, Y. & Ur Rehman, M. A. Improvement in the surface properties of stainless steel via zein/hydroxyapatite composite coatings for biomedical applications. Surf. Interfaces 20, 100589. https://doi.org/10.1016/J.SURFIN.2020.100589 (2020).
Louvier-Hernández, J. F. et al. Effect of the variation of the electrodeposition time of hydroxyapatite/chitosan coatings on AISI 316L SS. J. Compos. Mater. 55(29), 4421–4430. https://doi.org/10.1177/00219983211038621 (2021).
Aydemir, T. et al. Morphological and mechanical characterization of chitosan/gelatin/silica-gentamicin/bioactive glass coatings on orthopaedic metallic implant materials. Thin Solid Films 732, 138780. https://doi.org/10.1016/J.TSF.2021.138780 (2021).
Cordero-Arias, L. et al. Electrophoretic deposition of nanostructured-TiO2/chitosan composite coatings on stainless steel. RSC Adv. 3(28), 11247–11254. https://doi.org/10.1039/C3RA40535D (2013).
Measuring Adhesion by Tape Test per ASTM D3359 Issues and Challenges. https://kta.com/kta-university/adhesion-astm-d3359/. Accessed 07 Mar 2023.
Singh, S., Singh, G. & Bala, N. Electrophoretic deposition of Fe3O4 nanoparticles incorporated hydroxyapatite-bioglass-chitosan nanocomposite coating on AZ91 Mg alloy. Mater. Today Commun. 26, 101870. https://doi.org/10.1016/J.MTCOMM.2020.101870 (2021).
Mehedi Hasan, M., Nuruzzaman Khan, M., Haque, P. & Rahman, M. M. Novel alginate-di-aldehyde cross-linked gelatin/nano-hydroxyapatite bioscaffolds for soft tissue regeneration. Int. J. Biol. Macromol. 117, 1110–1117. https://doi.org/10.1016/J.IJBIOMAC.2018.06.020 (2018).
Zhang, H. et al. Effect of particle size on adhesion strength of bovine hydroxyapatite layer on Ti-12Cr coated by using electrophoretic deposition (EPD) method. IOP Conf. Ser. Mater. Sci. Eng. 1041(1), 012054. https://doi.org/10.1088/1757-899X/1041/1/012054 (2021).
Chen, Q. et al. Alginate/Bioglass® composite coatings on stainless steel deposited by direct current and alternating current electrophoretic deposition. Surf. Coat. Technol. 233, 49–56. https://doi.org/10.1016/J.SURFCOAT.2013.01.042 (2013).
Gabor, R. et al. Hybrid coatings for orthopaedic implants formed by physical vapour deposition and microarc oxidation. Mater. Des. https://doi.org/10.1016/J.MATDES.2022.110811 (2022).
Moskalewicz, T. et al. Electrophoretic deposition, microstructure, and corrosion resistance of porous sol-gel glass/polyetheretherketone coatings on the Ti-13Nb-13Zr alloy. Metall. Mater. Trans. A Phys. Metall. Mater. Sci. 48(5), 2660–2673. https://doi.org/10.1007/S11661-017-4030-0/TABLES/1 (2017).
Lee, J. H., Khang, G., Lee, J. W. & Lee, H. B. Interaction of different types of cells on polymer surfaces with wettability gradient. J. Colloid Interface Sci. 205(2), 323–330. https://doi.org/10.1006/JCIS.1998.5688 (1998).
Bolto, B., Tran, T., Hoang, M. & Xie, Z. Crosslinked poly(vinyl alcohol) membranes. Prog. Polym. Sci. 34(9), 969–981. https://doi.org/10.1016/J.PROGPOLYMSCI.2009.05.003 (2009).
De Oliveira, A. V. B., Kartnaller, V., Costa Neto, C. & Cajaiba, J. Effects of solvent polarity on the reaction of aldehydes and ketones with a hydrazide-bound scavenger resin. ACS Omega 4(8), 13530–13537. https://doi.org/10.1021/ACSOMEGA.9B01874 (2019).
Vafa, E., Bazargan-Lari, R. & Bahrololoom, M. E. Electrophoretic deposition of polyvinyl alcohol/natural chitosan/bioactive glass composite coatings on 316L stainless steel for biomedical application. Prog. Org. Coat. 151, 106059. https://doi.org/10.1016/J.PORGCOAT.2020.106059 (2021).
Shi, Y. Y. et al. Electrophoretic deposition of graphene oxide reinforced chitosan-hydroxyapatite nanocomposite coatings on Ti substrate. J. Mater. Sci. Mater. Med. 27(3), 1–13. https://doi.org/10.1007/S10856-015-5634-9 (2016).
Aldana, A. A., Malatto, L., Ur Rehman, M. A., Boccaccini, A. R. & Abraham, G. A. Fabrication of gelatin methacrylate (GelMA) scaffolds with nano- and micro-topographical and morphological features. Nanomaterials 9(1), 120. https://doi.org/10.3390/NANO9010120 (2019).
Avcu, E. et al. Tailoring the surface characteristics of electrophoretically deposited chitosan-based bioactive glass composite coatings on titanium implants via grit blasting. Prog. Org. Coat. 123, 362–373. https://doi.org/10.1016/J.PORGCOAT.2018.07.021 (2018).
Ureña, J. et al. Cellular behaviour of bone marrow stromal cells on modified Ti-Nb surfaces. Mater. Des. 140, 452–459. https://doi.org/10.1016/J.MATDES.2017.12.006 (2018).
Boyan, B. D. et al. Surface roughness mediates its effects on osteoblasts via protein kinase A and phospholipase A2. Biomaterials 20(23–24), 2305–2310. https://doi.org/10.1016/S0142-9612(99)00159-3 (1999).
Nawaz, A., Bano, S., Yasir, M., Wadood, A. & Ur Rehman, M. A. Ag and Mn-doped mesoporous bioactive glass nanoparticles incorporated into the chitosan/gelatin coatings deposited on PEEK/bioactive glass layers for favorable osteogenic differentiation and antibacterial activity. Mater. Adv. 1(5), 1273–1284. https://doi.org/10.1039/D0MA00325E (2020).
Wang, K. et al. Characterization of chondroitin sulfates isolated from large hybrid sturgeon cartilage and their gastroprotective activity against ethanol-induced gastric ulcers. Food. Chem. https://doi.org/10.1016/J.FOODCHEM.2021.130436 (2021).
Krishna Rao, K. S. V. & Ha, C. S. PH Sensitive hydrogels based on acryl amides and their swelling and diffusion characteristics with drug delivery behavior. Polym. Bull. 62(2), 167–181. https://doi.org/10.1007/S00289-008-0011-1/FIGURES/9 (2009).
Hu, Y. et al. Biomimetic mineralized hierarchical hybrid scaffolds based on in situ synthesis of nano-hydroxyapatite/chitosan/chondroitin sulfate/hyaluronic acid for bone tissue engineering. Colloids Surf. B Biointerfaces 157, 93–100. https://doi.org/10.1016/J.COLSURFB.2017.05.059 (2017).
Soundrapandian, C., Bharati, S., Basu, D. & Datta, S. Studies on novel bioactive glasses and bioactive glass-nano-HAp composites suitable for coating on metallic implants. Ceram. Int. 37(3), 759–769. https://doi.org/10.1016/J.CERAMINT.2010.10.025 (2011).
Mozafari, M., Moztarzadeh, F. & Tahriri, M. Investigation of the physico-chemical reactivity of a mesoporous bioactive SiO2-CaO-P2O5 glass in simulated body fluid. J. Non Cryst. Solids 356(28–30), 1470–1478. https://doi.org/10.1016/J.JNONCRYSOL.2010.04.040 (2010).
TahmasbiRad, A., Solati-Hashjin, M., Osman, N. A. A. & Faghihi, S. Improved bio-physical performance of hydroxyapatite coatings obtained by electrophoretic deposition at dynamic voltage. Ceram. Int. 40(8), 12681–12691. https://doi.org/10.1016/J.CERAMINT.2014.04.116 (2014).
He, D. et al. Effect of hydrothermal treatment temperature on the hydroxyapatite coatings deposited by electrochemical method. Surf. Coat. Technol. 406, 126656. https://doi.org/10.1016/J.SURFCOAT.2020.126656 (2021).
Saadaoui, S. et al. Performance of natural-dye-sensitized solar cells by ZnO nanorod and nanowall enhanced photoelectrodes. Beilstein J. Nanotechnol. 8(1), 287–295. https://doi.org/10.3762/BJNANO.8.31 (2017).
Musa, M. S. M. et al. Henna extract as a potential sacrificial agent in reducing surfactant adsorption on kaolinite: The role of salinity. J. King Saud Univ. Eng. Sci. 32(8), 543–547. https://doi.org/10.1016/J.JKSUES.2019.06.001 (2020).
Cai, F.-F., Heid, S. & Boccaccini, A. R. Potential of Laponite® incorporated oxidized alginate–gelatin (ADA-GEL) composite hydrogels for extrusion-based 3D printing. J. Biomed. Mater. Res. B Appl. Biomater. 109(8), 1090–1104. https://doi.org/10.1002/JBM.B.34771 (2021).
Fernandes, H. R. et al. Bioactive glasses and glass-ceramics for healthcare applications in bone regeneration and tissue engineering. Materials 11(12), 2530. https://doi.org/10.3390/MA11122530 (2018).
Mudali, K., Sridhar, T. M. & Raj, B. Corrosion of bio implants. Sadhana 28, 601–637 (2003).
Zhang, X. L., Jiang, Z. H., Yao, Z. P., Song, Y. & Wu, Z. D. Effects of scan rate on the potentiodynamic polarization curve obtained to determine the Tafel slopes and corrosion current density. Corros. Sci. 51(3), 581–587. https://doi.org/10.1016/J.CORSCI.2008.12.005 (2009).
Gebhardt, F. et al. Characterization of electrophoretic chitosan coatings on stainless steel. Mater. Lett. 66(1), 302–304. https://doi.org/10.1016/J.MATLET.2011.08.088 (2012).
Liu, L., Xu, J., Xie, Z. H. & Munroe, P. The roles of passive layers in regulating the electrochemical behavior of Ti5Si3-based nanocomposite films. J. Mater. Chem. A Mater. 1(6), 2064–2078. https://doi.org/10.1039/C2TA00510G (2013).
Potucek, R. K., Rateick, R. G. & Birss, V. I. Impedance characterization of anodic barrier al oxide film beneath porous oxide layer. J. Electrochem. Soc. 153(8), B304. https://doi.org/10.1149/1.2208737/XML (2006).
Begum, S., Johnson, W. E., Worthington, T. & Martin, R. A. The influence of pH and fluid dynamics on the antibacterial efficacy of 45S5 Bioglass. Biomed. Mater. 11(1), 015006. https://doi.org/10.1088/1748-6041/11/1/015006 (2016).
Agathopoulos, S. et al. Formation of hydroxyapatite onto glasses of the CaO–MgO–SiO2 system with B2O3, Na2O, CaF2 and P2O5 additives. Biomaterials 27(9), 1832–1840. https://doi.org/10.1016/J.BIOMATERIALS.2005.10.033 (2006).
Pishbin, F. et al. Single-step electrochemical deposition of antimicrobial orthopaedic coatings based on a bioactive glass/chitosan/nano-silver composite system. Acta Biomater. 9(7), 7469–7479. https://doi.org/10.1016/J.ACTBIO.2013.03.006 (2013).
Ur Rehman, M. A., Bastan, F. E., Nawaz, A., Nawaz, Q. & Wadood, A. Electrophoretic deposition of PEEK/bioactive glass composite coatings on stainless steel for orthopedic applications: an optimization for in vitro bioactivity and adhesion strength. Int. J. Adv. Manuf. Technol. 108(5–6), 1849–1862. https://doi.org/10.1007/S00170-020-05456-X (2020).
Kim, H. M., Himeno, T., Kawashita, M., Kokubo, T. & Nakamura, T. The mechanism of biomineralization of bone-like apatite on synthetic hydroxyapatite: An in vitro assessment. J. R. Soc. Interface 1(1), 17–22. https://doi.org/10.1098/RSIF.2004.0003 (2004).
Miguez-Pacheco, V., Hench, L. L. & Boccaccini, A. R. Bioactive glasses beyond bone and teeth: Emerging applications in contact with soft tissues. Acta Biomater. 13, 1–15. https://doi.org/10.1016/J.ACTBIO.2014.11.004 (2015).
Maqbool, M. et al. Synthesis, characterization, antibacterial properties, and in vitro studies of selenium and strontium co-substituted hydroxyapatite. Int. J. Mol. Sci. 22(8), 1–18. https://doi.org/10.3390/ijms22084246 (2021).
Khalili, V., Khalil-Allafi, J., Frenzel, J. & Eggeler, G. Bioactivity and electrochemical behavior of hydroxyapatite-silicon-multi walled carbon nano-tubes composite coatings synthesized by EPD on NiTi alloys in simulated body fluid. Mater. Sci. Eng. C 71, 473–482. https://doi.org/10.1016/j.msec.2016.10.036 (2017).
Zheng, K. et al. Toward highly dispersed mesoporous bioactive glass nanoparticles with high cu concentration using cu/ascorbic acid complex as precursor. Front. Chem. 7(July), 1–15. https://doi.org/10.3389/fchem.2019.00497 (2019).
Chen, X., Lei, B., Wang, Y. & Zhao, N. Morphological control and in vitro bioactivity of nanoscale bioactive glasses. J. Non Cryst. Solids 355(13), 791–796. https://doi.org/10.1016/J.JNONCRYSOL.2009.02.005 (2009).
Zhu, Y. et al. Preparation, characterization and in vitro bioactivity of mesoporous bioactive glasses (MBGs) scaffolds for bone tissue engineering. Microporous Mesoporous Mater. 112(1–3), 494–503. https://doi.org/10.1016/J.MICROMESO.2007.10.029 (2008).
Ravichandiran, P., Sheet, S., Premnath, D., Kim, A. R. & Yoo, D. J. 1,4-Naphthoquinone analogues: Potent antibacterial agents and mode of action evaluation. Molecules 24(7), 1437. https://doi.org/10.3390/MOLECULES24071437 (2019).
Abdur, M. et al. Improving dyeability and antibacterial activity of Lawsonia inermis L on jute fabrics by chitosan pretreatment. Text. Cloth Sustain. 3(1), 1–10. https://doi.org/10.1186/S40689-016-0023-4 (2017).
Khosravi, F. et al. A bilayer GO/nanofibrous biocomposite coating to enhance 316L stainless steel corrosion performance. Mater Res Express 6(8), 086470. https://doi.org/10.1088/2053-1591/AB26D5 (2019).
Farrokhi-Rad, M., Beygi Khosrowshahi, Y., Hassannejad, H., Nouri, A. & Hosseini, M. Preparation and characterization of hydroxyapatite/titania nanocomposite coatings on titanium by electrophoretic deposition. Mater. Res. Express 5(11), 115004. https://doi.org/10.1088/2053-1591/AADBE8 (2018).
Acknowledgements
The authors extend their appreciation to the Deanship of Scientific Research at King Khalid University (KKU) for funding this research through the Research Group Program Under the Grant No.:(R.G.P.2/515/44).
Author information
Authors and Affiliations
Contributions
The main idea has been suggested by M.A.U.R. and M.H.N.; Conceptualization of the manuscript: M.H.N. and A.A. Investigation, methodology, and validation: A.Q.R. and A.A.; Writing the main manuscript: H.S. and O.B.I.; Review and editing: M.H.N. and M.A.U.R. All the authors read the paper and give the feedback.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Nawaz, M.H., Aizaz, A., Ropari, A.Q. et al. A study on the effect of bioactive glass and hydroxyapatite-loaded Xanthan dialdehyde-based composite coatings for potential orthopedic applications. Sci Rep 13, 17842 (2023). https://doi.org/10.1038/s41598-023-44870-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-44870-5
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.