Abstract
In-office bleaching, using hydrogen peroxide, is effective to remove dental enamel stains. However, bleaching agents can deteriorate surface properties of CAD-CAM materials. This in vitro study aimed to investigate the effect of in-office bleaching agents on Vickers hardness and surface topography of polished and unpolished dental CAD-CAM composite materials (Grandio blocs, Lava Ultimate, BRILLIANT Crios, Cerasmart), and a polymer-infiltrated ceramic network block (Vita Enamic). The specimens were randomly divided into two groups: unpolished or polished. The micro-hardness and surface topography of each group were measured before bleaching, after a 60 min bleaching period, and 24-h and one-month post-bleaching. In-office bleaching significantly influenced the Vickers hardness of both the polished and unpolished CAD/CAM composite blocks, with Vita Enamic exhibiting the least hardness stability among all groups. Furthermore, in-office bleaching significantly influenced the surface roughness of unpolished CAD/CAM composite blocks. There was a significant difference in hardness reduction between the polished and unpolished specimens for most of the investigated materials at different time points. The bleaching did not influence the surface roughness of the investigated polished group, except for Vita Enamic and Lava Ultimate. However, it did influence the surface roughness of the investigated materials in the unpolished group.
Similar content being viewed by others
Introduction
Aesthetic CAD/CAM restorative materials in dentistry include predominantly ceramics and resin-based composites1. Ceramics are favoured because they offer superior biocompatibility, aesthetics and strength compared and contrasted to resin-based composites2,3. CAD/CAM composites have improved mechanical properties compared to the direct resin composites due to the innovative composition and polymerisation modes under high temperature and/or pressure4,5. Compared to ceramics, the CAD/CAM composite blocks have similar hardness and stiffness to that of the tooth structure which is beneficial for repair, wear reduction, and, improvement of clinical performance, longevity and machinability of the material3,6. Currently, CAD/CAM composite blocks can be classified based on their microstructure as follows: the polymer-infiltrated ceramic network (PICN), which can be described as a porous ceramic network infiltrated with a polymer network, or a resin-composite block (RCB), which is a resin-composite formed by mixing the polymer and filler components under high pressure and high temperature7,8. One of the main aesthetic disadvantages of CAD/CAM composite blocks is their susceptibility to staining9,10. However, they offer more colour stability than the conventional direct and indirect resin-composite (photo polymerised in the clinic or dental laboratory) materials11,12 due to the higher degree of polymerization and improved mechanical properties13. Consequently, bleaching of such restorations might be requested after a short- or long-term period to enhance and restore their aesthetic appearance14.
The colour stability of dental restorations is very essential for both the patients and clinicians, mainly because of aesthetical reasons. However, it can be affected surprisingly by many intrinsic and extrinsic factors including dietary habits, medical history of the patient, exposure time, and concentration of the staining agents15,16. Discolouration of the dental restorations can be influenced by their composition (photo-initiators, activators, resin matrix, silane coupling agent and fillers), physicochemical reactions, hydrophilicity/hydrophobicity, and the water sorption of the materials17. Other key factors related to the success of resin composite restorations include incomplete polymerisation, curing time and devices, porosities, and oxygen inhibition at the surface, and surface treatments18.
Chemical bleaching methods mainly include carbamide and/or hydrogen peroxide gels in different concentrations of the reactive ingredient. In-office bleaching using hydrogen peroxide is an effective method of removing tooth stains of intrinsic and extrinsic origin19. This approach utilises a high-concentration hydrogen peroxide (H2O2, HP; 35% to 40%) that oxidises the colour stains and pigments on the tooth surface20,21. The main advantage of in-office bleaching is the ability to achieve tooth whitening in one dental visit. In contrast, it can cause tooth sensitivity and tissue irritation22. Carbamide peroxide (CP) at different concentrations (10% to 20%) is mainly used for home bleaching23. The main advantages of home bleaching are ease of use, less chair-side time, and less tooth sensitivity and gingival irritation after bleaching24,25. However, such bleaching agents might not be as safe for restorative materials as they are for the tooth enamel, and their use could lead to surface degradation, changes in surface roughness, erosion and ultimately failure26,27,28. Bleaching with hydrogen peroxide, for instance, has been found to affect the three-dimensional polymer network in polymerised composites14. Furthermore, in-office and home bleaching agents might increase the staining susceptibility of restorative materials25,29.
The surface roughness of the CAD/CAM composite restoration might increase over time30 due to the consumption of different food and beverages9,31,32 or as a result of teeth brushing9,33,34. Increased surface roughness might render the restorative materials more prone to discolouration32,33,34,35,36. Furthermore, this might make the restoration more susceptible to bleaching agents and lead to inferior mechanical properties, such as reduced hardness35. Many studies have investigated the effect of bleaching agents on colour changes, optical properties, and topography28,29,36,37,38,39. However, few have investigated the effect bleaching has on the mechanical properties, such as hardness and surface roughness, of both polished and unpolished restorative materials.
This current study aimed to investigate the influence of an in vitro bleaching system (in-office bleaching system) on the Vickers hardness and surface roughness of five CAD/CAM composite blocks. The null hypotheses were as follows: (i) the bleaching agents have no influence on the micro-hardness of the investigated materials; (ii) bleaching duration and material type do not have an influence on the hardness reduction of the investigated materials; (iii) treating the surface of the investigated materials (polished and unpolished) does not impact the hardness reduction after bleaching; (iv) filler weight does not have an impact on the hardness reduction of the investigated materials; and (v) bleaching agents do not have an impact on the surface roughness of the investigated materials.
Materials and methods
Sample preparation
Five CAD/CAM blocks were investigated: four resin-composite blocks (RCB), Grandio blocs (Gr), Lava Ultimate (Lu), BRILLIANT Crios (Bc) and Cerasmart (Cs); and one polymer-infiltrated ceramic network (PICN) block Enamic (En), as shown in Table 1. They were selected due to their wider applications as representative CAD/CAM blocks for aesthetic restorations.
The CAD/CAM blocks were sectioned into rectangular bar shaped specimens (14 mm × 12 mm × 2 mm) using a cutting machine (MECATCH234, PRESI, France) under constant water cooling (Fig. 1). The specimens were wet-ground and polished using a polishing machine (BETA-VECTOR, Buehler, IL, USA) with silicon carbide (SiC) papers (P1200, P2500 and P4000 grit, Buehler, IL, USA) under water cooling, followed by a 0.25 µm diamond suspension polishing (Meta Di Supreme, Buehler, IL, USA). The specimens were cleansed in an ultrasonic water bath (Ultrasonic Cleaning System; L&R, NJ, USA) for 5 min. The specimen dimensions were confirmed to an accuracy of ± 0.1 mm using a digital calliper. Any specimens not within this range were discarded. The sample size for each experiment was calculated initially using mean differences, standard deviations, and confidence interval of 95% and found to be sufficient with significance level of 0.05.
Bleaching procedure
Thirty samples of each material (15 polished and 15 unpolished) were randomly distributed into three study groups: four samples were used as control (unbleached), four for Vickers hardness, four samples for surface roughness, and three for SEM analysis. All samples were stored in distilled water at 37 °C for 3 months40 (ISO 10993-13, 2010) before the bleaching procedure was performed using Opalescence Boost (in-office bleaching) for three intervals of 20 min (total 60 min). The bleaching procedure was performed by one investigator at room temperature, with the bleaching agent covering the whole top surface of each specimen. At the end of the respective bleaching procedure, the specimens were rinsed with a high-pressure water flow, dried with blotting paper and airflow, and placed in fresh distilled water for subsequent measurements.
Micro-hardness measurement
Micro-hardness of each specimen (n = 4) was measured using a Vickers micro-hardness instrument (HXD-1000 TMC, Shanghai Taiming Optical instrument, Shanghai, China). A fixed load of 300 gf was applied for 20 s. Ten indentations at a 0.5 mm interval were made randomly on each sample. The machine then automatically calculated the corresponding hardness value and presented the Vickers hardness number (VHN). For in-office bleaching, surface micro-hardness was measured before bleaching, after 60 min of bleaching and at 24-h and 1-month post-bleaching. VHN was also measured for the corresponding control samples from each group. The samples were cleaned and dried before the micro-hardness measurement.
The hardness reduction (HR as a percentage) after bleaching storage was calculated using Eq. (1).
where VHN(before) and VHN(after) indicate the Vickers hardness numbers before and after bleaching respectively for each time point.
Surface roughness
The surface roughness of each specimen (n = 4) was measured using a stylus contact type profilometer (Mahr Perthometer M1 [Lt = 5.6 mm, λc = 0.800 mm]). Ra, the arithmetic mean height of the roughness profile, was recorded during the measurement. Three vertical and three horizontal lines were measured on the specimen surface to record six Ra values for each specimen, and the mean Ra result was subsequently calculated. Surface roughness was also measured before bleaching and at the same timeframes after bleaching and post-bleaching similar to hardness measurement.
Scanning electron microscope imaging
Each specimen was attached to aluminium stubs (12 mm thickness) with double-sided adhesive tabs. The specimens were sputter-coated with gold and examined with a scanning electron microscope (FESEM, S-4800, Hitachi, Tokyo, Japan) (n = 3). SEM micrographs were produced at × 40k magnifications of representative areas of the samples.
Statistical analyses
The data were analysed using a statistical software package (GraphPad Prism, version 9.1.2 (226) and found to exhibit normal distribution according to the Shapiro–Wilk test. Two-way ANOVA was performed to investigate the material’s effect, storage time effect, and their interaction. One-way ANOVA was followed by the Tukey’s post hoc analysis for multiple comparisons between different materials and different time points. The Pearson correlation was determined to identify the correlation between the hardness reduction and filler weight percentages, in both the polished and unpolished groups. An independent t-test was performed to measure differences between the polished and unpolished groups (without bleaching, after 60 min of bleaching, 24 h and one-month post-bleaching) and for differences between the bleached and unbleached groups at each time point for each material. All tests were carried out at α = 0.05.
Results
The reduction of hardness percentage was calculated 60 min after bleaching, after 24 h and after one-month and for the control unbleached samples at the same time points. There was a significant difference between the bleached and unbleached (control) specimens for each material, as confirmed by the independent sample t-test (Table 2 and Fig. 2).
After 60 min bleaching of the polished samples, the highest reduction of hardness was found for En, followed by Gr, Cs, Bc and Lu, with significant differences between all materials except Cs and Bc. The same was observed for the unpolished samples in the following order: En, Lu, Gr, Bc and Cs. There were significant differences between all the materials. Notably, there was an insignificant difference in the reduction of hardness between the polished and unpolished Gr and Cs specimens (Table 2).
After 24 h bleaching of the polished samples, the reduction of hardness was the highest for En followed by Gr, Lu, Cs and Bc, with significant differences between all the materials. The same was observed for the unpolished samples in the following order: En, Gr, Lu, Bc, and Cs. A significant difference was observed between all the materials. Whereas, remarkably, there was a significant difference in hardness reduction between the polished and unpolished samples for all investigated materials.
One-month post-bleaching, the reduction of hardness of the polished samples was the highest for En followed by Lu, Gr, Cs and Bc, with a significant difference between all the materials except Cs and Bc. The same was observed for the unpolished specimens in the following order: En, Lu, Gr, Bc and Cs. A significant difference was observed for all the materials except Cs and Bc. Notably, there was a significant difference in the reduction of hardness between the polished and unpolished samples for all the investigated materials except En.
Two-way ANOVA showed a significant material effect and time effect, including a significant interaction for hardness reduction (p < 0.0001) with more influence of the material effect. The greatest influence in the polished group was for the CAD-CAM material (partial eta squared ηp2 = 0.798) followed by the interaction effect (ηp2 = 0.099) while time had the lowest effect (ηp2 = 0.063). The greatest influence in the unpolished group was for the CAD-CAM material (partial eta squared ηp2 = 0.84) followed by the time effect (ηp2 = 0.11) while interaction had the lowest effect (ηp2 = 0.05).
The Pearson correlation of the reduction of hardness and filler weight percentage (data obtained from a previous study32 ) showed an insignificant positive correlation between filler weight and the reduction of hardness in the polished group R2 = 0.7, p = 0.076 and filler weight and the reduction of hardness in the unpolished group R2 = 0.62, p = 0.115. There was also an insignificant positive correlation in the reduction of hardness between polished and unpolished groups R2 = 0.52, p = 0.166 (Fig. 3).
Ra values recorded before bleaching, directly after bleaching, and after one month are presented in Table 3 and Fig. 4. The bleaching treatment did not influence surface roughness for all the investigated materials in the polished group except En and Lu. En showed significantly increased Ra values after bleaching from both before bleaching and at one-month post-bleaching. Lu from the polished group exhibited significantly increased Ra values after a month. Bleaching influenced the surface roughness of all investigated materials in the unpolished group. En showed significantly reduced Ra values after one-month post-bleaching from both before and after bleaching. Also Gr showed significantly reduced Ra values after 60 min of bleaching and one month post bleaching from that of before bleaching. Lu showed significantly increased Ra values after one-month post-bleaching and after 60 min of bleaching from that before bleaching. Cs showed significantly increased Ra values after bleaching from both before bleaching and one-month post-bleaching. Finally, Bc showed significantly increased Ra values after one month of bleaching compared to both before and after 60 min of bleaching.
SEM images at a × 40k magnification showed less demarcated particle margins and more rounded particles directly after bleaching and after one-month post-bleaching when compared with both the polished and unpolished samples (Figs. 5 and 6). Small cracks were found in the matrix phase of both polished and unpolished specimens, especially one-month post-bleaching. For the polished specimens, En and Gr showed deeper grooves, whereas Bc and Cs exhibited no remarkable changes after one month. Nevertheless, Lu presented more dark spaces (the polymer matrix) and more prominent clustering of filler particles. More remarkable surface deterioration and margin fractures were observed for the unpolished specimens than for the specimens in the polished group. Unpolished Cs and En did not exhibit remarkable surface morphology variations.
Discussion
In the present study there was a significant difference in hardness reduction percentages between the bleached and unbleached (control) specimens for each material, and thus, the first null hypothesis was rejected. Moreover, there were significant material and time effects, with a significant interaction for the reduction of hardness (p < 0.0001) with more influence from the material effect. Given that, the second null hypothesis was rejected as well. Markedly, there was a significant difference in the reduction of hardness between polished and unpolished specimens for all investigated materials, and thus, the third null hypothesis was rejected. The filler weight percentage showed an insignificant effect on the reduction of hardness, and thus, the fourth null hypothesis was accepted. The bleaching influenced the surface roughness of some of the investigated materials, and thus, the fifth null hypothesis was partially accepted.
En showed the highest hardness reduction of all investigated materials for both the polished and unpolished surfaces at all time points. This was an interesting finding as En is a PICN composed of an interpenetrating ceramic-polymer network that is strong and resistant to breakdown41. Previous studies have found that En has the least hardness reduction when compared to other RCBs upon storage in different media42,43. However, this contradicted the findings of some alternative studies, which, in contrary, showed an increase in the material microhardness44,45. This might be attributable to the fact that bleaching agents can penetrate and diffuse through the polymeric matrix of the material to a greater extent than the other storage media such as water, artificial saliva or 70% ethanol solution43 due to oxidative cleavage of the polymer chains46 or similar solubility factor to that of the bleaching agent47. Furthermore, the samples in this study were stored in water for three months to simulate clinical conditions as such the materials would have been bleaching after servicing for a while in the oral cavity while the compared studies have measured bleaching effect without any previous storage in water.
Nevertheless, RCBs were less affected by the in-office bleaching procedure. GR exhibited the highest reduction of hardness of all the resin-composite blocks. However, it has the highest filler percentage (86 wt.%). This, again, contradicted previous findings42,48 and could be attributed to the aforementioned reason of different experimental conditions. Lu, Bc and Cs had similar filler weight percentages (75 wt.%, 70 wt.% and 66 wt.%) and the same level of the reduction of hardness. Lu contains more zirconium silicate in its filler composition; as such, it is more prone to hydrolysis of the silane-coupling agent as a consequence of inefficient salinization of high crystalline content in the zirconium silicate49or due to material inhomogeneity and presences of large filler particles50. Then again, silicate materials are more prone for silane-aided adhesion promotion than zirconia or zirconium silicate. However, silanes may degrade over time in resin composites51. Furthermore, nano-cluster filler particles in Lu typically have defects and voids, which could explain the higher levels of surface degradation4. Lu with zirconia nanoparticles has been found to exhibit higher softening resistance compared to En with a feldspathic ceramic structure. This is in line with studies reporting that zirconia-containing materials have higher hardness and strength values than feldspathic-containing materials52,53. Although bleaching agents can influence the surface microhardness of dental restorations, the mechanism for such changes is not fully clear. One possible explanation is that the peroxides in bleaching agents release very reactive free radicals at the resin-filler interphase. These free radicals may attack glass particles, silica, and alumina, causing a separation of fillers and filler-matrix debonding54. Alternative explanations are that the bleaching agents can cause an oxidative cleavage of the polymer chains46 or that the resin matrix has a similar solubility factor to that of the bleaching agent47. Bleaching agents might have a greater effect on the surface microhardness at higher temperatures28.
All unpolished surfaces exhibited a significantly higher hardness reduction. When servicing in the oral environment and exposed to fluids, acids and moisture, the surface roughness of the materials tends to increase9,30,31,32, rendering the restoration more prone to penetration by bleaching agents which affect their physical properties, such as microhardness35,55. Our finding might indicate that polishing dental restoration before bleaching procedures is advisable to reduce any potential softening of the restorative materials.
Two-way ANOVA showed significant material and time effects with a significant interaction for hardness reduction (p < 0.0001) with more influence from the material effect. Considering the different resin matrices and filler compositions of CAD/CAM composite blocks, the bleaching agents can cause various changes in the material’s microhardness and surface roughness. This indicates that bleaching effects are material dependent.
The reduction of hardness was greatest after 60 min bleaching and increased slightly after 24 h and after one month. This finding is consistent with other studies, as most material changes occur in the first interaction with a solvent or contacting solution, here a bleaching agent, after which the material effect may reach an equilibrium56,57,58,59. Further, the bleaching agent might be diluted with a storage medium (deionized water) after performing the bleaching for the recommended time. In this study, the lowered hardness values were positively correlated with the amount of filler loading for all CAD/CAM composite materials, where En with the highest weight percentage of fillers (86%), exhibited the least softening resistance. On the other hand, factors other than filler type and concentration, such as microstructure homogeneity, cross-linking between the fillers, and resin matrix, have a significant impact on the interaction between the bleaching agents and dental materials54. However, all the materials experienced hardness reduction over time due to plasticization of the polymer matrix caused by water sorption and consequently degradation and reduction in material stiffness42,60.
In this research, both profilometry and SEM were used to study the surface topography of the materials of interest. In-office bleaching did not influence the surface roughness of any of the investigated materials of the polished group except for En, which showed significantly increased Ra values after 60 min bleaching when compared with the values before bleaching and one-month post-bleaching. Polished Lu specimens exhibited significantly increased Ra values after one month. This finding was in line with similar studies29,54. This can be attributed to the Bis-GMA composition of Lu, as Bis-GMA-containing materials have higher surface roughness values46. Furthermore, for the unpolished group, the lower Ra values of Lu might be attributed to the fact that it has smaller filler size than En or the highly cross-linked polymer matrix and zirconia fillers of Lu, which resist free radicals caused by bleaching agents54.
Furthermore, the bleaching agent and diverse dental materials may chemically interact in a way that changes the surface topography54. Surface roughness might increase due to the composition, exposure time, and concentration of bleaching agents61. The increased surface roughness of dental restorations can cause discolouration and secondary caries by enhancing and accelerating biofilm accumulation. The Ra value should not exceed 0.2 μm to prevent biofilm accumulation62. This value had not been exceeded for all polished samples; however, it was exceeded for all the unpolished samples except CS. Bleaching influenced the surface roughness of for all the investigated materials in the unpolished group of specimens.
Compared to the unbleached condition, SEM images at ×40k for the polished specimens, En and Gr exhibited deeper flaws, whereas Bc and Cs showed no significant changes after one month. Lu contained more dark spaces (the polymer matrix) and a more prominent clustering of filler particles. That being said, more remarkable surface deterioration and margin fractures were observed on the unpolished specimens compared with the polished group. Unpolished Cs and En did not present significant surface morphology variations.
In this study, all samples were stored in water at 37 °C as simulator of intraoral fluids61 and temperature and being more reflective of the clinical conditions. According to ISO standards (ISO 10993-13), any devices intended to be used for more than 30 days and tested in simulated conditions should be tested at 1-month, 3-month, 6-month, and 1-year40, hence a short term storage for 3 months was applied.
Future work should involve bleaching at high temperatures and using 3D micro-CT or AFM to facilitate a deeper understanding of the changes bleaching causes inside the materials.
Conclusion
The following can be concluded: the hardness of CAD/CAM composite blocks was affected by in-office bleaching, with PICN exhibiting the least hardness stability of all of the resin-composite blocks. In-office bleaching significantly influenced the surface roughness of unpolished CAD/CAM composite blocks. In summary, polishing the restorations in advance of a bleaching procedure is advisable.
Data availability
The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.
References
Fasbinder, D. Materials for chairside CAD/CAM restorations. Compend. Contin. Educ. Dent. (Jamesburg, N.J.: 1995) 31, 702–704, 706, 708, 709 (2010).
Lawson, N. C., Bansal, R. & Burgess, J. O. Wear, strength, modulus and hardness of CAD/CAM restorative materials. Dent. Mater. 32, e275–e283. https://doi.org/10.1016/j.dental.2016.08.222 (2016).
Ruse, N. D. & Sadoun, M. J. Resin-composite blocks for dental CAD/CAM applications. J. Dent. Res. 93, 1232–1234. https://doi.org/10.1177/0022034514553976 (2014).
Zhang, Y. & Kelly, J. R. Dental ceramics for restoration and metal veneering. Dent. Clin. N. Am. 61, 797–819. https://doi.org/10.1016/j.cden.2017.06.005 (2017).
Hensel, F. et al. CAD/CAM resin-based composites for use in long-term temporary fixed dental prostheses. Polymer 13, 3469 (2021).
Moshaverinia, A. Review of the modern dental ceramic restorative materials for esthetic dentistry in the minimally invasive age. Dent. Clin. N. Am. 64, 621–631. https://doi.org/10.1016/j.cden.2020.05.002 (2020).
Awada, A. & Nathanson, D. Mechanical properties of resin-ceramic CAD/CAM restorative materials. J. Prosthet. Dent. 114, 587–593. https://doi.org/10.1016/j.prosdent.2015.04.016 (2015).
Nguyen, J. F., Ruse, D., Phan, A. C. & Sadoun, M. J. High-temperature-pressure polymerized resin-infiltrated ceramic networks. J. Dent. Res. 93, 62–67. https://doi.org/10.1177/0022034513511972 (2014).
Mühlemann, S., Bernini, J. M., Sener, B., Hämmerle, C. H. & Özcan, M. Effect of aging on stained monolithic resin-ceramic CAD/CAM materials: Quantitative and qualitative analysis of surface roughness. J. Prosthodont. 28, e563–e571. https://doi.org/10.1111/jopr.12949 (2019).
Kang, Y. A. et al. Color stability of dental reinforced CAD/CAM hybrid composite blocks compared to regular blocks. Mater (Basel) https://doi.org/10.3390/ma13214722 (2020).
Kara, R. Discoloration of CAD/CAM blocks and bulk-fill composite resin materials after thermocycling. IOSR J. Dent. Med. Sci. https://doi.org/10.9790/0853-1904070815 (2020).
Quek, S., Yap, A., Rosa, V., Tan, K. & Teoh, K. Effect of staining beverages on color and translucency of CAD/CAM composites. J. Esthet. Restor. Dent. https://doi.org/10.1111/jerd.12359 (2018).
Yano, H. T. et al. Correlation between microstructure of CAD/CAM composites and the silanization effect on adhesive bonding. J. Mech. Behav. Biomed. Mater. 101, 103441. https://doi.org/10.1016/j.jmbbm.2019.103441 (2020).
Stawarczyk, B. et al. Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glass-ceramic: Effect of storage media, duration, and subsequent polishing. Dent. Mater. J. 31, 377–383. https://doi.org/10.4012/dmj.2011-238 (2012).
Nasim, I., Neelakantan, P., Sujeer, R. & Subbarao, C. V. Color stability of microfilled, microhybrid and nanocomposite resins—An in vitro study. J. Dent. 38(Suppl 2), e137-142. https://doi.org/10.1016/j.jdent.2010.05.020 (2010).
Poggio, C. et al. Color stability of esthetic restorative materials: A spectrophotometric analysis. Acta Biomater. Odontol. Scand. 2, 95–101. https://doi.org/10.1080/23337931.2016.1217416 (2016).
Fonseca, A. S. Q. S. et al. Effect of monomer type on the CC degree of conversion, water sorption and solubility, and color stability of model dental composites. Dent. Mater. 33, 394–401. https://doi.org/10.1016/j.dental.2017.01.010 (2017).
Reis, A. F., Giannini, M., Lovadino, J. R. & Ambrosano, G. M. Effects of various finishing systems on the surface roughness and staining susceptibility of packable composite resins. Dent. Mater. 19, 12–18. https://doi.org/10.1016/s0109-5641(02)00014-3 (2003).
Alharbi, A., Ardu, S., Bortolotto, T. & Krejci, I. In-office bleaching efficacy on stain removal from CAD/CAM and direct resin composite materials. J. Esthet. Restor. Dent. 30, 51–58. https://doi.org/10.1111/jerd.12344 (2018).
Mori, A. A. et al. Susceptibility to coffee staining during enamel remineralization following the in-office bleaching technique: An in situ assessment. J. Esthet. Restor. Dent. 28(Suppl 1), S23-31. https://doi.org/10.1111/jerd.12134 (2016).
Kwon, S. R. & Wertz, P. W. Review of the mechanism of tooth whitening. J. Esthet. Restor. Dent. 27, 240–257. https://doi.org/10.1111/jerd.12152 (2015).
Reis, A., Tay, L., Herrera, D., Kossatz, S. & Loguercio, A. Clinical effects of prolonged application time of an in-office bleaching gel. Oper. Dent. 36, 590–596 (2011).
Bernardon, J. K. et al. Clinical performance of vital bleaching techniques. Oper. Dent. 35, 3–10 (2010).
Leonard, R. H. Jr., Haywood, V. B., Caplan, D. J. & Tart, N. D. Nightguard vital bleaching of tetracycline-stained teeth: 90 months post treatment. J. Esthet. Restor. Dent. 15, 142–153 (2003).
Irusa, K., Alrahaem, I. A., Ngoc, C. N. & Donovan, T. Tooth whitening procedures: A narrative review. Dent. Rev. 2, 100055. https://doi.org/10.1016/j.dentre.2022.100055 (2022).
Yu, H., Zhang, C. Y., Wang, Y. N. & Cheng, H. Hydrogen peroxide bleaching induces changes in the physical properties of dental restorative materials: Effects of study protocols. J. Esthet. Restor. Dent. 30, E52–E60 (2018).
Gouveia, T. H. N. et al. Effect of at-home bleaching with different thickeners and aging on physical properties of a nanocomposite. Eur. J. Dent. 10, 082–091 (2016).
Yu, H., Li, Q., Cheng, H. & Wang, Y. The effects of temperature and bleaching gels on the properties of tooth-colored restorative materials. J. Prosthet. Dent. 105, 100–107. https://doi.org/10.1016/S0022-3913(11)60007-3 (2011).
Tinastepe, N., Malkondu, O., Iscan, I. & Kazazoglu, E. Effect of home and over the contour bleaching on stainability of CAD/CAM esthetic restorative materials. J. Esthet. Restor. Dent. 33, 303–313. https://doi.org/10.1111/jerd.12604 (2021).
Kamonkhantikul, K., Arksornnukit, M., Takahashi, H., Kanehira, M. & Finger, W. J. Polishing and toothbrushing alters the surface roughness and gloss of composite resins. Dent. Mater. J. 33, 599–606 (2014).
Schroeder, T. et al. Factors affecting the color stability and staining of esthetic restorations. Odontology 107, 507–512 (2019).
Farahat, D. S. & El-Wassefy, N. A. Effects of food-simulating solutions on the surface properties of two CAD/CAM resin composites. J. Clin. Exp. Dent. 14, e782–e790. https://doi.org/10.4317/jced.59822 (2022).
Labban, N. et al. Influence of toothbrush abrasion and surface treatments on roughness and gloss of polymer-infiltrated ceramics. Polymers 13, 3694 (2021).
Fiore, A., Bollero, P., Basilicata, M., Stellini, E. & Monaco, C. Effect of toothpaste on the surface roughness of the resin-contained CAD/CAM dental materials: A systematic review. J. Clin. Med. https://doi.org/10.3390/jcm11030767 (2022).
Sharafeddin, F., Kowkabi, M. & Shoale, S. Evaluation of the effect of home bleaching agents on surface microhardness of different glass-ionomer cements containing hydroxyapatite. J. Clin. Exp. Dent. 9, e1075–e1080. https://doi.org/10.4317/jced.53852 (2017).
Karakaya, I. & Cengiz-Yanardag, E. Changes in optical characteristics and surface topography of CAD/CAM materials after bleaching applications: An AFM evaluation. J. Prosthodont. 29, 226–236. https://doi.org/10.1111/jopr.13134 (2020).
Elsaka, S., Taibah, S. & Elnaghy, A. Effect of staining beverages and bleaching on optical properties of a CAD/CAM nanohybrid and nanoceramic restorative material. BMC Oral Health 22, 96. https://doi.org/10.1186/s12903-022-02136-y (2022).
Peña, R. C., Simóes, R., Ramos, A. C., Dovigo, L. N. & Fonseca, R. G. Effect of in-office bleaching on color, translucency, and whiteness variations in CAD-CAM monolithic materials. Oper. Dent. 46, 428–437. https://doi.org/10.2341/20-119-l (2021).
Gasparik, C. et al. Effect of accelerated staining and bleaching on chairside CAD/CAM materials with high and low translucency. Dent. Mater. J. 38, 987–993. https://doi.org/10.4012/dmj.2018-335 (2019).
ISO10993-13. Biological Evaluation of Medical Devices—Part 13: Identification and Quantification of Degradation Products from Polymeric Medical Devices. (2010).
Saba, D. A., Salama, R. A. & Haridy, R. Effect of different beverages on the color stability and microhardness of CAD/CAM hybrid versus feldspathic ceramic blocks: An in-vitro study. Futur. Dent. J. 3, 61–66. https://doi.org/10.1016/j.fdj.2017.07.001 (2017).
Alamoush, R. A., Sung, R., Satterthwaite, J. D. & Silikas, N. The effect of different storage media on the monomer elution and hardness of CAD/CAM composite blocks. Dent. Mater. 37, 1202–1213. https://doi.org/10.1016/j.dental.2021.04.009 (2021).
Colombo, M., Poggio, C., Lasagna, A., Chiesa, M. & Scribante, A. Vickers micro-hardness of new restorative CAD/CAM dental materials: Evaluation and comparison after exposure to acidic drink. Mater (Basel, Switzerland) https://doi.org/10.3390/ma12081246 (2019).
Rangel, J., Zanatta, R. & Albuquerque, A. The effect of bleaching gel application on the physical properties of different CAD/CAM restorative materials. J. Dent. Health Oral Disord. Ther. 12, 41–44 (2021).
Alshali, R. Z. & Alqahtani, M. A. The effect of home and in-office bleaching on microhardness and color of different CAD/CAM ceramic materials. Materials 15, 5948 (2022).
Polydorou, O., Mönting, J. S., Hellwig, E. & Auschill, T. M. Effect of in-office tooth bleaching on the microhardness of six dental esthetic restorative materials. Dent. Mater. 23, 153–158. https://doi.org/10.1016/j.dental.2006.01.004 (2007).
Yap, A. U. & Wattanapayungkul, P. Effects of in-office tooth whiteners on hardness of tooth-colored restoratives. Oper. Dent. 27, 137–141 (2002).
Al-Harbi, F. A., Ayad, N. M., ArRejaie, A. S., Bahgat, H. A. & Baba, N. Z. Effect of aging regimens on resin nanoceramic chairside CAD/CAM material. J. Prosthodont. 26, 432–439. https://doi.org/10.1111/jopr.12408 (2017).
Druck, C. C., Pozzobon, J. L., Callegari, G. L., Dorneles, L. S. & Valandro, L. F. Adhesion to Y-TZP ceramic: Study of silica nanofilm coating on the surface of Y-TZP. J. Biomed. Mater. Res. B Appl. Biomater. 103, 143–150. https://doi.org/10.1002/jbm.b.33184 (2015).
Koenig, A. et al. Characterisation of the filler fraction in CAD/CAM resin-based composites. Materials 14, 1986 (2021).
Matinlinna, J. P., Lung, C. Y. K. & Tsoi, J. K. H. Silane adhesion mechanism in dental applications and surface treatments: A review. Dent. Mater. 34, 13–28. https://doi.org/10.1016/j.dental.2017.09.002 (2018).
Mormann, W. H. et al. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: Two-body wear, gloss retention, roughness and Martens hardness. J. Mech. Behav. Biomed. Mater. 20, 113–125. https://doi.org/10.1016/j.jmbbm.2013.01.003 (2013).
Swain, M. V., Coldea, A., Bilkhair, A. & Guess, P. C. Interpenetrating network ceramic-resin composite dental restorative materials. Dent. Mater. 32, 34–42. https://doi.org/10.1016/j.dental.2015.09.009 (2016).
Karakaya, İ & Cengiz, E. Effect of 2 bleaching agents with a content of high concentrated hydrogen peroxide on stained 2 CAD/CAM blocks and a nanohybrid composite resin: An AFM evaluation. Biomed. Res. Int. 2017, 6347145. https://doi.org/10.1155/2017/6347145 (2017).
Attin, T., Hannig, C., Wiegand, A. & Attin, R. Effect of bleaching on restorative materials and restorations—A systematic review. Dent. Mater. 20, 852–861. https://doi.org/10.1016/j.dental.2004.04.002 (2004).
Van Landuyt, K. L. et al. How much do resin-based dental materials release? A meta-analytical approach. Dent. Mater. 27, 723–747. https://doi.org/10.1016/j.dental.2011.05.001 (2011).
Alshali, R. Z., Salim, N. A., Sung, R., Satterthwaite, J. D. & Silikas, N. Analysis of long-term monomer elution from bulk-fill and conventional resin-composites using high performance liquid chromatography. Dent. Mater. 31, 1587–1598. https://doi.org/10.1016/j.dental.2015.10.006 (2015).
Łagocka, R. et al. Analysis of base monomer elution from 3 flowable bulk-fill composite resins using high performance liquid chromatography (HPLC). Med. Sci. Monit. 24, 4679–4690. http://europepmc.org/abstract/MED/29980660 (2018).
Sunbul, H. A., Silikas, N. & Watts, D. C. Surface and bulk properties of dental resin-composites after solvent storage. Dent. Mater. 32, 987–997. https://doi.org/10.1016/j.dental.2016.05.007 (2016).
Ferracane, J. L. Hygroscopic and hydrolytic effects in dental polymer networks. Dent. Mater. 22, 211–222. https://doi.org/10.1016/j.dental.2005.05.005 (2006).
Hafez, R., Ahmed, D., Yousry, M., El-Badrawy, W. & El-Mowafy, O. Effect of in-office bleaching on color and surface roughness of composite restoratives. Euro J. Dent. 4, 118–127 (2010).
Ionescu, A. et al. Influence of matrix and filler fraction on biofilm formation on the surface of experimental resin-based composites. J. Mater. Sci. Mater. Med. 26, 5372. https://doi.org/10.1007/s10856-014-5372-4 (2015).
Alamoush, R. A., Silikas, N., Salim, N. A., Al-Nasrawi, S. & Satterthwaite, J. D. Effect of the composition of CAD/CAM composite blocks on mechanical properties. BioMed. Res. Int. 2018, 4893143. https://doi.org/10.1155/2018/4893143 (2018).
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by R.A.A. The first draft of the manuscript was written by R.A.A. and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript. J.Y.: Conceptualization, Methodology, Software, Data curation, Writing-Original draft preparation, Visualization, Investigation. A.A.: Reviewing and editing. J.H.: Supervision, conceptualization, validation, reviewing and editing. J.M.: Proofreading, editing and supervision. A.E.: Supervision, conceptualization, validation, reviewing and editing. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Alamoush, R.A., Yang, J., Alhotan, A. et al. The effect of in-office bleaching agents on the Vickers hardness and surface topography of polished and unpolished CAD/CAM composite materials. Sci Rep 13, 15341 (2023). https://doi.org/10.1038/s41598-023-42415-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-42415-4
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.