Abstract
Our aim was to evaluate the circadian rhythm of motor activity, body position and integrated variable TAP (composed by wrist Temperature, motor Activity and body Position) in Sleep Disordered Breathing (SDB), its relation to SDB severity and the effect of continuous positive airway pressure (CPAP) on these circadian rhythms. To do this, we monitored motor activity and body position rhythms of 78 SDB patients (53.3 ± 1.2 years old, 26.9% women) and 32 healthy subjects (51.4 ± 3.2 years old, 43.8% women) for 1 week. On the last day of that week, SDB patients underwent a polysomnography followed by a Maintenance of Wakefulness Test, Multiple Sleep Latency Test and Sustained Attention to Response Task protocol. A subgroup of 18 moderate to severe SDB patients was treated with CPAP and monitored again after 3 months under treatment. A non-parametrical analysis was performed to characterize the circadian patterns to assess differences between groups and associations between sleep and circadian parameters. Circadian variables were altered in SDB, exhibiting a direct relationship to SDB severity. The motor activity pattern showed a clear improvement with CPAP treatment. Thus, circadian ambulatory monitoring, including the integrated variable TAP, could be used to evaluate the circadian alterations caused by SDB and activity pattern to monitor the effect of CPAP treatment.
Similar content being viewed by others
Introduction
The circadian system is the main responsible for the temporal regulation of most physiological processes, including thermoregulation, metabolism or the sleep–wake cycle1. Among these processes, the sleep–wake cycle is regulated by an homeostatic sleepiness accumulation, a circadian process and sleep inertia2, 3.
The increasing prevalence of SDB through the world has become a major health concern, due to its multiple consequences including hypertension, diabetes, cardiovascular and cerebrovascular disease, cognitive impairment and even cancer4. The chronodisruptive effect of SDB is supported by both the circadian system alteration at several levels, such as thermoregulation or the sleep–wake cycle itself5,6,7,8, and the circadian restoration of sleep, blood pressure, thermoregulation, immune response or haemostatic system by Continuous Positive Airway Pressure (CPAP)5, 6, 9,10,11,12,13. Also, this relationship seems bidirectional since the circadian system modulates the incidence and length of apnoea events14.
The rest-activity marker rhythm is inherently associated to the sleep–wake cycle15, used as choice method for circadian sleep disorders assessment16 and has been validated against polysomnography in SDB patients17. However, isolated marker rhythms are submitted to masking, thus multivariable recordings15, 18, 19 and variable integration have been developed15. In this sense, the integrated variable TAP (composed by wrist Temperature, motor Activity and body Position) developed for sleep detection and successfully validated against polysomnography15, 20, can improve the accuracy provided by a single marker rhythm15, 21.
Thus, the main purpose of this study was to evaluate the circadian rhythm of motor activity, body position and the integrated TAP variable in order to determine how these rhythms are affected by sleep disordered breathing severity and continuous positive airway pressure treatment, and in consequence Ambulatory Circadian Monitoring (ACM) could constitute a screening tool for this disorder as well as CPAP efficacy under free-living conditions.
Results
Clinical and polysomnographic characteristics
From the consecutive SDB patients originally studied (n = 98), twenty were excluded due to the following reasons: irregular sleep–wake rhythms (n: 3), acute sleep deprivation prior to the sleep study (n: 1), REM sleep without atonia (n: 1), severe depressive symptoms (n: 1), migraines during the nap protocol (n: 1) and removing the sensors (i.e. insufficient data for analysis) either at home or during the PSG procedure (n: 13). Then, the group finally comprised 78 adults with a wide spectrum of disease (see our previous work5 for clinical and polysomnographic characteristics). With regard to the 30 patients requiring CPAP, one refused to complete the protocol and 11 presented non valid recordings (removing the sensors or insufficient monitoring time); therefore, 18 moderate-to-severe SDB patients receiving CPAP were revaluated at least 6 weeks after the baseline study. PSG revealed a complete resolution of SDB in all patients and improved excessive daytime sleepiness measured by ESS, BSI sleepiness index, MSLT-SL, MWT-SL and MWT-E. However, CPAP treatment did not improve SART errors (see Martinez-Nicolas et al.5).
Circadian characteristics of sleep disordered breathing
Daily mean patterns and circadian parameters of motor activity, body position and TAP variable for SDB patients (n: 78) and healthy subjects (n: 32) are shown in Fig. 1 and Table 1. When comparing rhythms for motor activity of SDB patients and healthy subjects, SDB patients showed lower circadian stability as indicated by decreased IS (General Linear Model controlled by age, sex and BMI; p < 0.05), as well as higher RA and daytime values (M10) and a phase advance in TL5 for body position than healthy subjects. Finally, TAP pattern (and index of general activation) of SDB patients showed lower IS, CFI and daytime values (M10) compared with healthy subjects (General Linear Model controlled by age, sex and BMI; p < 0.05).
The decision tree to discern between healthy subjects (n: 32) and SDB patients (n: 78) selected WT stability (IS) with a maximum agreement rate (89.2%) at 0.53 (sensitivity = 88.5%; specificity = 91.7%; positive predictive value = 97.5%; negative predictive value = 68.8%). The ROC curve shows an area under the curve of 0.89 (p < 0.001) as shown in Fig. 2. The second most discriminant variable chosen by the decision tree was the TAP robustness (CFI) with a cut-off point of 0.79 (Fig. 2), reached an agreement rate of 80.2% (sensitivity = 79.4%; specificity = 85.7%; a positive predictive value = 97.5%; negative predictive value = 37.5%) and the ROC area under the curve was 0.794 (p < 0.001).
Circadian impairment by sleep disordered breathing severity
The SDB severity effect on the circadian rhythmic parameters (Fig. 3) was addressed by comparing snorers/mild (n: 31), moderate (n: 19) and severe SDB (n: 28) by a General Linear Model controlled for age, sex and BMI, and followed by a Bonferroni’s post hoc analysis (Table 2). The motor activity pattern of snorers/mild apnoea group compared to severe group (Fig. 3A and Table 2) showed a more stable pattern and lower values at night (L5), this latter also occurred for body position rhythm together with a phase advance (TL5) and higher day/night contrast (RA) (Fig. 3B and Table 2), presenting moderate group intermediate values. Finally, the integrated variable TAP showed a more stable (IS) and robust pattern (CFI) in the snorers/mild apnoea group compared to severe group (Fig. 3C and Table 2), being the moderate group in an intermediate status. In addition, the mild/snorers group showed lower N1, AI, AHI, CT90, ODI3, BSI and higher N3, REM, REM Episodes, MSAT, NSAT and MWT-E than severe SDB group, with moderate group again with intermediate values as it was previously published5.
The best criteria to discriminate, by means of a decision tree, from mild (n: 31) to severe (n: 28) SDB patients, was TAP robustness (CFI) with a cut-off point of 0.62 yielding an agreement rate of 83.3% (sensitivity = 96.9%; specificity = 67.9%; positive predictive value = 77.5%; negative predictive value = 95.0%). The ROC for TAP robustness (Fig. 4) reached an area under the curve of 0.87 (p < 0.001). Since previously, WT pattern impairment has been reported as changing according to SDB severity5, the best WT parameter for SBD classification was also assessed. Thus, WT robustness, as measured by CFI, with a cut-off point of 0.44, yielded an agreement rate of 76.7% (sensitivity = 81.3%; specificity = 71.4%; a positive predictive value = 76.5%; negative predictive value = 76.9%) and the ROC area under the curve was 0.76 (p < 0.01) as it is shown in Fig. 4, that it is, ROC curve for TAP robustness tended to reach better results than for WT robustness (p = 0.067) for discriminating SDB severity.
Regression analysis for sleep and circadian parameters
Regression analysis was performed to determine the association between sleep and circadian parameters (n: 78). It was controlled for age, sex and BMI. For motor activity (Supplementary Table 1), higher time in N1 stage and CT90 were associated with increased night activity values (L5) and the subsequent decrease of RA. Higher percentage of N3 was correlated with higher RA and lower CT90 was associated to higher CFI. In the case of body position (Supplementary Table 2), MWT-E was positively associated with high IS, RA and CFI whereas a high ODI3 and low NSAT were related with a delay in the nocturnal phase marker (TL5). Finally, the most relevant parameters of TAP variable were significantly associated to decreased nocturnal sleep quality parameters and poorer outcomes of diurnal MWT-E and MSLT-E tests (Supplementary Table 3).
CPAP treatment
The influence of CPAP treatment on circadian parameters was addressed by a Mixed Effects Model (n: 18). For the motor activity pattern, CPAP reduced fragmentation (IV), nocturnal activity (L5) and increased day-night contrast (RA) as it is shown in Fig. 5A and Table 3. In addition, diurnal body position (M10) was decreased with the CPAP treatment (Fig. 5B and Table 3). CPAP tended to decrease TAP variable nocturnal values (L5) while increasing day/night contrast (Fig. 5C and Table 3).
Finally, the decision tree to discern between pre-treatment and CPAP treated severe patients (n: 15) selected a value of 10.4°/min for nocturnal activity (L5) with an agreement rate of 86.7% (sensitivity = 100.0%; specificity = 73.3%; positive predictive value = 78.9%; negative predictive value = 100.0%). The Fig. 6 shows its corresponding ROC curve reaching an area under the curve of 0.87 (p < 0.01). Again, when comparing with the best WT parameter (CFI), agreement rate was 68.6% with a cut-off point of 0.44 (sensitivity = 66.7%; specificity = 64.7%; positive predictive value = 66.7%; negative predictive value = 64.7%) and the ROC area under the curve was 0.68 (p = 0.11). Then, ROC curve for nocturnal activity (L5) tended to reach better results than for WT robustness (p = 0.063).
Discussion
Our results highlight that SDB impairs rest-activity, body position and TAP variable circadian rhythms in accordance to SDB severity, whereas CPAP treatment improves motor activity pattern. Besides circadian parameters allow quantitative classification of populations providing a useful clinical screening tool for SDB and CPAP efficacy.
SDB patients showed lower stability and robustness for motor activity and the integrated variable TAP than healthy subjects, conditions related to other sleep disorders20, ageing22 and cancer chemotherapy circadian impairment23. In the case of body position, SDB patients experienced a nocturnal phase advance, a characteristic associated with an aged circadian system22, 24, 25, and a more standing position during daytime, probably due to the less pronounced nap period in our sample.
The above-mentioned differences between healthy and SDB subjects´ circadian rhythms can be used as a screening tool for SBD prone population. In a previous paper we showed that SDB patients exhibited lower wrist temperature stability values (IS) with respect to healthy subjects with an agreement rate of 89%, probably due to apnoea-dependent sympathetic activation at night26 and the subsequent excessive daytime sleepiness5 which can contribute to frequent and unexpected or arrhythmic WT fluctuations.
The severity of SDB, as measured by the Apnea–Hypopnea Index27, seems to impair circadian indexes (stability, fragmentation, amplitude and robustness), reinforcing the hypothesis of circadian disruption caused by sleep apnoea5, as also occurs with other pathological conditions such as obesity, metabolic syndrome, diabetes, cardiovascular disease or, even, mortality risk28,29,30,31. Nocturnal values were increased for activity, body position and TAP variable as SDB severity progressed, which indicates a less deep sleep5, 20, 32, confirmed by the increase in N1 duration and the decrease of N3 and REM duration. Besides, and according to regression analyses, TAP stability, fragmentation, amplitude, robustness and nocturnal values impairment were related to higher daytime sleepiness as measured by MWT and MSLT as it was previously suggested for WT5, and could be a reflect of the sleep structure impairment15. Thus, these circadian alterations can be used as a screening procedure to detect individuals prone to suffer SDB before their definitive diagnosis in a sleep unit. Moreover, low TAP robustness, assessed by CFI, allowed distinction in SBD severity reaching an agreement rate of 83%. Given that the CFI variable can be used as an indicator of circadian system status15, SDB worsening could implicate a progressive deterioration of the circadian system.
The restorative effect of CPAP treatment has been thoroughly demonstrated for sleepiness5 and sleep itself33, 34, but also for other alterations such as core body temperature rhythm6, cognitive impairment4, metabolic syndrome35, fibrinolytic10 and inflammatory markers13, coagulation factors11, blood pressure12 or autonomic function36. Although the main limitation of this study is the absence of the individual adherence and compliance CPAP data, all monitored patients accomplished at least five hours per night during six consecutive weeks37 of CPAP treatment, an threshold value for an objective CPAP use that has demonstrated its efficacy for improving nocturnal sleep34. In this sense, the activity pattern a great improvement occurred, probably because CPAP treatment reduces nocturnal awakenings38 and, hence, would reduce nocturnal activity. Previous studies reported no effect of CPAP treatment39, 40, probably due to differences in treatment compliance or monitoring device sensitivity. Activity nocturnal values diminution, and the subsequent increase in amplitude, were compatible with a less fragmented41 and deeper sleep due to the reduced number of arousals5, as also supported by lesser time in N1 and the AI and SDB indexes improvement. In accordance with the nocturnal decrease in activity level, L5 values can be used to assess CPAP efficacy with an agreement rate of 86%.
In summary, although WT robustness allow us to discern between SDB patients and healthy subjects, when motor activity, body position and TAP robustness are considered reliability for discriminating between mild and severe SDB as well as CPAP usage increases with respect to wrist temperature alone (83% vs 77%, and 87% vs 65%, respectively).
Considering jointly motor activity, body position and WT in the integrated variable TAP reveals that Sleep Disordered Breathing patients present circadian disruption, that increases with the severity of the disease and improves with Continuous Positive Airway Pressure treatment. Thus, TAP variable could constitute, a useful screening tool for SBD prevalence and severity as well as treatment efficacy adherence.
Materials and methods
In a previous study5, we analysed the wrist temperature (WT) circadian pattern in the same group of subjects, using the information from the ACM devices. In the current study we will focus on the information provided by the circadian pattern of motor activity, body position and integrated variable TAP as well as data provided by the Maintenance of Wakefulness Test (MWT), and the Multiple Sleep Latency Test (MSLT).
Ninety-eight consecutive patients with suspected SDB (Table 4) were evaluated at the Hospital Clinic of Barcelona in the Multidisciplinary Sleep Disorders Unit, as previously described in Martinez-Nicolas et al., 20175. The patients were informed about the objectives of the study, the willingness of their participation and that whatever their decision, it would not affect their treatment. Participants who accepted to participate in the study signed an informed consent. Exclusion criteria were being under 18 years of age, use of medications affecting wakefulness or sleep, shift work or irregular sleep–wake schedules during the four weeks before the sleep study, and major medical or psychiatric disorders. Patients with any concomitant sleep disorder other than SDB were excluded by nocturnal polysomnography (PSG).
A total of 32 healthy subjects were recruited (age and gender balanced with the SDB patients) at the Chronobiology Lab of the University of Murcia (Table 4). They are included in this study in order to illustrate healthy circadian patterns for activity, body position and TAP. Exclusion criteria were the same as those applied to the SDB patients, but also included snoring (as reported during a personal interview) and/or excessive daytime sleepiness (Epworth Sleepiness Scale score higher than 12)42.
The study follows the bioethical principles set out by the Declaration of Helsinki. Data from the volunteers were protected according to Spanish Law 15/1999 from 13 September. The study was approved by the Hospital Clinic of Barcelona and the University of Murcia ethics committees for the SDB patients and healthy subjects, respectively.
Design
Healthy volunteers were monitored for an entire week whereas SDB patients were monitored 6 days under free-living conditions and an additional day, the last one, under controlled conditions in hospital. During this week, the subjects were encouraged to maintain their habitual life style. Since PSG and nap-protocols could interfere with the normal sleep pattern of the patients43, both test were performed at the end of the monitoring period, allowing at least 6 days of continuous recordings (the minimum for a reliable non-parametrical analysis, according to literature44).
For ambulatory circadian monitoring, all subjects wore a Thermochron iButton DS1921H (Maxim Integrated Products, Sunnyvale, CA) programmed to sample every 10 min over the whole week to measure WT32, placed on the wrist of the non-dominant hand over the radial artery as already described5, 45,46,47, and isolated from the environment by a double-sided cotton sport wrist band32. In addition, every subject was monitored with a HOBO Pendant G Acceleration Data Logger UA- 004–64 actimeter (Onset Computer, Bourne, MA) programmed every 30 s, positioned on the non-dominant arm by means of a sport band for motor activity and body position monitoring as already described15, 20, 45. Briefly, motor activity was measured as the rate of change in degrees per minute and position represents the angle between the X-axis of the accelerometer (parallel to the humerus bone of the arm) and the horizontal plane. Data from activity and body position were averaged for 10-min intervals to facilitate WT comparisons. Wrist Temperature, motor Activity and body Position were combined in order to obtain the integrated variable TAP, according to the algorithms previously described15. In summary, and as previously described5, 15, 20,21,22, each variable was normalized between 0 and 1 and averaged to obtain the integrated variable (TAP). Thus, a TAP value of 1 indicates the lowest values of WT, the highest values of activity and a standing position (compatible with wake periods), whereas a score of 0 corresponds to the highest WT values, the lowest activity values and a horizontal position (compatible with sleep periods)15.
On the last day of the week, patients with suspected SDB underwent a 24-h sleep study, including questionnaires and neurophysiological tests as previously described5. After admission, the Epworth Sleepiness Scale (ESS) and Barcelona Sleepiness Index (BSI) were used to assess subjective daytime sleepiness42, 48. Nocturnal PSG was performed according to standard practice parameters and diagnostic criteria49, 50 with sleep stages independently and manually double scored according to the American Academy of Sleep Medicine (AASM) criteria, using 30 s epochs51. The nap protocol was initiated the morning after PSG in order to objectively measure daytime sleepiness throughout the day (review Guaita et al., 2015 for further details48). In brief, we used the research version protocol comprising 5 sets of the Maintenance of Wakefulness Test (MWT), the Multiple Sleep Latency Test (MSLT) that started at 08:30 and every 2 h onwards52. Each nap set was preceded by a measurement of vigilance with Sustained Attention to Response Task (SART), with a duration of 4 min53 and using commission errors, missed errors and total errors54. Due to their skewed distribution, MWT and MSLT were log transformed previously to statistical analysis.
Continuous positive airway pressure treatment
From the cohort of 78 patients, eighteen moderate or severe SDB patients with resistant hypertension or excessive daytime sleepiness were treated with CPAP and evaluated again following the same protocol (nocturnal PSG followed by SART-MSLT-MWT protocol). CPAP titration was performed following the recommendations of the Spanish Sleep Society55. CPAP compliance was measured objectively using a built-in CPAP meter. For the analysis, five hours per night, measured by the CPAP, during six consecutive weeks were considered the strict minimum use of CPAP37.
Data analysis
The WT data were obtained, filtered and processed from data previously reported5. The mean daily patterns for motor activity, body position and TAP variable were calculated per individual, and then averaged per group.
In order to characterize the aforementioned circadian rhythms a nonparametric analysis was performed as previously described5. This analysis determines the following parameters: interdaily stability (the constancy of the 24-h rhythmic pattern over days, IS), intradaily variability (rhythm fragmentation, IV), relative amplitude (RA) and circadian function index (CFI) calculated by the integration of IS, IV and RA oscillating between 0 (absence of circadian rhythmicity) and 1 (robust circadian rhythm)15, 56. RA was calculated as the difference between M10 (average of 10-min intervals for the 10 consecutive hours with maximum values) and L5 (average of 10-min intervals for the 5 consecutive hours of minimum values) divided by the sum of M10 and L5 for variables with acrophase during daytime (activity, body position and TAP), as previously published41, 56. The timing for L5 and M10 were used as nocturnal and diurnal phase markers (TL5 and TM10, respectively).
Circadian variables parameters in healthy subjects and SDB patients were compared using a General Linear Model controlled by age, gender and body mass index (BMI). Differences between snorers/mild SDB (AHI < 15 events/hours), moderate SDB (AHI between 15 and 30 events/hour) and severe SDB (AHI > 30 events/hour) were assessed by a General Linear Model controlled by age, gender and BMI (followed by post hoc pairwise comparisons and a Bonferroni test). In addition, a regression analysis was performed between sleep and circadian parameters controlling again for age, gender and BMI (with Bonferroni correction for multiple comparisons). A Mixed Effects Model was performed to determine the effect of CPAP treatment on SDB patients.
Circadian parameters for WT (showed in a previous work5), activity, body position and TAP were entered in WEKA version 3.8.3 (University of Waikato, Hamilton, New Zealand)57. An independent classification was then performed to discern between i) healthy subjects and SDB patients, ii) mild and severe SDB patients and iii) pre-treatment and CPAP therapy groups by means of a J.4.8 decision tree that uses the C 4.5 algorithm for decision making58, which selects the decision that maximizes information gain at each step. In order to simplify the algorithm, all decision trees were required to use only one decision. Each individual decision tree corresponds to the best of 100 iterations performed with 66% of the data randomly selected and checked against the other 33%. Then, specificity (test’s ability to detect correctly (i) SDB patients, (ii) severe SDB patients and (iii) pre-treatment group), sensitivity (test’s ability to detect correctly (i) healthy subjects, (ii) mild SDB patients and (iii) CPAP therapy group), positive predictive value (proportion of positive results that are true positive; the positive results were (i) SDB, (ii) severe SDB patients and (iii) pre-treatment patients), negative predictive value (proportion of negative results that are true negative; the negative results were (i) healthy subjects, (ii) mild SDB patients and (iii) CPAP therapy group), agreement rate and ROC curve for every decision rule were calculated, which were compared by a Wilcoxon test. Data were processed using Microsoft Office Excel 2016, and all statistical analyses were performed using SPSS version 23.0 software (SPSS, Chicago, Illinois, USA). Values of p < 0.05 were considered to be statistically significant for General Linear Model and Wilcoxon test and p < 0.00625 for Regression analysis.
Data availability statement
The raw data supporting the conclusions of this manuscript are available on request to the corresponding author.
References
Buijs, R. M. et al. The suprachiasmatic nucleus balances sympathetic and parasympathetic output to peripheral organs through separate preautonomic neurons. J. Comp. Neurol. 464, 36–48 (2003).
Akerstedt, T. & Folkard, S. Predicting duration of sleep from the three process model of regulation of alertness. Occup. Environ. Med. 53, 136–141 (1996).
Kräuchi, K., Cajochen, C. & Wirz-Justice, A. Thermophysiologic aspects of the three-process-model of sleepiness regulation. Clin. Sports Med. 24, 287–300 (2005).
Lim, D. C. & Pack, A. I. Obstructive sleep apnea: Update and future. Annu. Rev. Med. 68, 99–112 (2017).
Martinez-Nicolas, A. et al. Circadian impairment of distal skin temperature rhythm in patients with sleep-disordered breathing: The effect of CPAP. Sleep 40, 2 (2017).
Moog, R., Fietze, I., Penzel, T., Peter, J. H. & Vogel, M. Circadian reactions to nCPAP treatment. Chronobiol. Int. 15, 265–273 (1998).
Lemmer, B., Scholtze, J. & Schmitt, J. Circadian rhythms in blood pressure, heart rate, hormones, and on polysomnographic parameters in severe obstructive sleep apnea syndrome patients. Blood Press. Monit. 21, 136–143 (2016).
Fleetham, J. et al. Canadian Thoracic Society guidelines: Diagnosis and treatment of sleep disordered breathing in adults. Can. Respir. J. 13, 387–392 (2006).
Silva, G. E. et al. Longitudinal evaluation of sleep-disordered breathing and sleep symptoms with change in quality of life: The Sleep Heart Health Study (SHHS). Sleep 32, 1049–1057 (2009).
Bagai, K. et al. Circadian variability of fibrinolytic markers and endothelial function in patients with obstructive sleep apnea. Sleep 37, 359–367 (2014).
Phillips, C. et al. Effects of continuous positive airway pressure on coagulability in obstructive sleep apnoea: A randomised, placebo-controlled crossover study. Thorax 67, 639–644 (2012).
Tamisier, R., Tan, C. O., Pepin, J.-L., Levy, P. & Taylor, J. A. Blood pressure increases in OSA due to maintained neurovascular sympathetic transduction: Impact of CPAP. Sleep 2, 2 (2015).
Jelic, S. et al. Inflammation, oxidative stress, and repair capacity of the vascular endothelium in obstructive sleep apnea. Circulation 117, 2270–2278 (2008).
Butler, M. P. et al. The circadian system contributes to apnea lengthening across the night in obstructive sleep apnea. Sleep 2, 2 (2015).
Ortiz-Tudela, E., Martinez-Nicolas, A., Campos, M., Rol, M. Á. & Madrid, J. A. A new integrated variable based on thermometry, actimetry and body position (TAP) to evaluate circadian system status in humans. PLoS Comput. Biol. 6, e1000996 (2010).
Morgenthaler, T. I. et al. Practice parameters for the clinical evaluation and treatment of circadian rhythm sleep disorders. An American Academy of Sleep Medicine report. Sleep 30, 1445–1459 (2007).
Dick, R. et al. AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch TM versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing. Physiol. Meas. 31, 1623–1633 (2010).
Kolodyazhniy, V. et al. Estimation of human circadian phase via a multi-channel ambulatory monitoring system and a multiple regression model. J. Biol. Rhythms 26, 55–67 (2011).
Kolodyazhniy, V. et al. An improved method for estimating human circadian phase derived from multichannel ambulatory monitoring and artificial neural networks. Chronobiol. Int. 29, 1078–1097 (2012).
Ortiz-Tudela, E. et al. Ambulatory circadian monitoring (ACM) based on thermometry, motor activity and body position (TAP): A comparison with polysomnography. Physiol. Behav. 126, 30–38 (2014).
Martinez-Nicolas, A. et al. Assessing chronotypes by ambulatory circadian monitoring. Front. Physiol. 10, 1396 (2019).
Martinez-Nicolas, A. et al. Circadian monitoring as an aging predictor. Sci. Rep. 8, 15027 (2018).
Ortiz-Tudela, E., Innominato, P. F., Rol, M. A., Lévi, F. & Madrid, J. A. Relevance of internal time and circadian robustness for cancer patients. BMC Cancer 16, 2 (2016).
Batinga, H. et al. Ontogeny and aging of the distal skin temperature rhythm in humans. Age 37, 29 (2015).
Roenneberg, T. et al. Epidemiology of the human circadian clock. Sleep Med. Rev. 11, 429–438 (2007).
Idiaquez, J., Santos, I., Santin, J., Del Rio, R. & Iturriaga, R. Neurobehavioral and autonomic alterations in adults with obstructive sleep apnea. Sleep Med. 15, 1319–1323 (2014).
Rapoport, D. Point: Is the AHI the best way to quantify the severity of sleep disordered breathing? - YES. Chest https://doi.org/10.1378/chest.15-1319 (2015).
Zuurbier, L. A. et al. Fragmentation and stability of circadian activity rhythms predict mortality—The Rotterdam study. Am. J. Epidemiol. 181, 54–63 (2015).
Sohail, S., Yu, L., Bennett, D. A., Buchman, A. S. & Lim, A. S. Irregular 24-hour activity rhythms and the metabolic syndrome in older adults. Chronobiol. Int. 32, 802–813 (2015).
Luik, A. I., Zuurbier, L. A., Hofman, A., Van Someren, E. J. W. & Tiemeier, H. Stability and fragmentation of the activity rhythm across the sleep-wake cycle: The importance of age, lifestyle, and mental health. Chronobiol. Int. 30, 1223–1230 (2013).
Garaulet, M. et al. Fragmentation of daily rhythms associates with obesity and cardiorespiratory fitness in adolescents: The HELENA study. Clin. Nutr. 36, 1558–1566 (2017).
Sarabia, J. A., Rol, M. Á., Mendiola, P. & Madrid, J. A. Circadian rhythm of wrist temperature in normal-living subjects. A candidate of new index of the circadian system. Physiol. Behav. 95, 570–580 (2008).
Dongol, E. M. & Williams, A. J. Residual excessive sleepiness in patients with obstructive sleep apnea on treatment with continuous positive airway pressure. Curr. Opin. Pulm. Med. 22, 589–594 (2016).
Neikrug, A. B. et al. Continuous positive airway pressure improves sleep and daytime sleepiness in patients with parkinson disease and sleep apnea. Sleep 37, 177–185 (2014).
Kanimozhi, S., Balaji, C., Saravanan, A. & Ravi, K. Effect of short term CPAP therapy in obstructive sleep apnea patients with metabolic syndrome. J. Clin. Diagnostic Res. 9, CC07-CC10 (2015).
Maser, R. E., Lenhard, M. J., Rizzo, A. A. & Vasile, A. A. Continuous positive airway pressure therapy improves cardiovascular autonomic function for persons with sleep-disordered breathing. Chest 133, 86–91 (2008).
Weaver, T. E. & Grunstein, R. R. Adherence to continuous positive airway pressure therapy: The challenge to effective treatment. Proc. Am. Thorac. Soc. 5, 173–178 (2008).
Cooke, J. R. et al. Continuous positive airway pressure deepens sleep in patients with Alzheimer’s disease and obstructive sleep apnea. Sleep Med. 10, 1101–1106 (2009).
West, S. D., Kohler, M., Nicoll, D. J. & Stradling, J. R. The effect of continuous positive airway pressure treatment on physical activity in patients with obstructive sleep apnoea: A randomised controlled trial. Sleep Med. 10, 1056–1058 (2009).
Bamberga, M. et al. Relationship between energy expenditure, physical activity and weight loss during CPAP treatment in obese OSA subjects. Respir. Med. 109, 540–545 (2015).
Van Someren, E. J. et al. Circadian rest-activity rhythm disturbances in Alzheimer’s disease. Biol. Psychiatry 40, 259–270 (1996).
Johns, M. A new method for measuring daytime sleepiness: The Epworth sleepiness scale. Sleep 14, 540–545 (1991).
Le Bon, O. et al. The first-night effect may last more than one night. J. Psychiatr. Res. 35, 165–172 (2001).
Van Someren, E. J. W. Improving actigraphic sleep estimates in insomnia and dementia: How many nights?. J. Sleep Res. 16, 269–275 (2007).
Martinez-Nicolas, A., Ortiz-Tudela, E., Rol, M. Á. & Madrid, J. A. Uncovering different masking factors on wrist skin temperature rhythm in free-living subjects. PLoS ONE 8, e61142 (2013).
Kräuchi, K., Cajochen, C. & Wirz-Justice, A. Waking up properly: Is there a role of thermoregulation in sleep inertia?. J. Sleep Res. 13, 121–127 (2004).
Kräuchi, K. et al. Diurnal and menstrual cycles in body temperature are regulated differently: A 28-day ambulatory study in healthy women with thermal discomfort of cold extremities and controls. Chronobiol. Int. 31, 102–113 (2014).
Guaita, M. et al. The Barcelona sleepiness index: A new instrument to assess excessive daytime sleepiness in sleep disordered breathing. J. Clin. Sleep Med. 11, 1289–1298 (2015).
American Academy of Sleep of Medicine. The international classification of sleep disorders: diagnostic and coding manual. (American Academy of Sleep Medicine, 2005). doi:https://doi.org/10.1212/WNL.41.1.160
Kushida, C. A. et al. Practice parameters for the indications for polysomnography and related procedures: An update for 2005. Sleep 28, 499–521 (2005).
Iber, C., Ancoli-Israel, S., Chesson, A. L. & Quan, S. F. The AASM manual for the scoring of sleep and associated events: Rules, terminology and technical specifications. (2007).
Littner, M. R. et al. Practice parameters for clinical use of the multiple sleep latency test and the maintenance of wakefulness test. Sleep 28, 113–121 (2005).
Robertson, I. H., Manly, T., Andrade, J., Baddeley, B. T. & Yiend, J. ‘Oops!’: Performance correlates of everyday attentional failures in traumatic brain injured and normal subjects. Neuropsychologia 35, 747–758 (1997).
Fronczek, R., Middelkoop, H. A., Van Dijk, J. G. & Lammers, G. J. Focusing on vigilance instead of sleepiness in the assessment of narcolepsy: High sensitivity of the sustained attention to response task (SART). Sleep 29, 187–191 (2006).
Lloberes, P. et al. Diagnosis and treatment of sleep apnea-hypopnea syndrome. Arch. Bronconeumol. 47, 143–156 (2011).
Witting, W., Kwa, I. H., Eikelenboom, P., Mirmiran, M. & Swaab, D. F. Alterations in the circadian rest-activity rhythm in aging and Alzheimer’s disease. 563–572 (1990).
Hall, M. et al. The WEKA data mining software: An update mark. SIGKDD Explor. 11, 10–18 (2009).
Kotsiantis, S. Supervised machine learning: A review of classification techniques. Informatica 31, 249–268 (2007).
Acknowledgements
The authors wish to express their appreciation to the late Dr. Joaquín Terán Santos for his interest in integrating different circadian variables for the detection of apnea.
Funding
This work was supported by the Ministry of Economy and Competitiveness, the Instituto de Salud Carlos III through CIBERFES (CB16/10/00239 and CB06/06/0025, awarded to JM and JMM, respectively); the Séneca Foundation through grant 19899/GERM/15 awarded to JM, the Ministry of Science Innovation and Universities and the Agencia Estatal de Investigación (AEI) through RTI2018-093528-B-I00 and Call H2020-sc1-BHC-2018–2020 (Grant agreement 825546, Diabfrail-Latam) to MAR (all of them co-financed by FEDER).
Author information
Authors and Affiliations
Contributions
A.M.N., M.G., J.S., J.A.M. and M.A.R. had the initial conception of the study, A.M.N. and M.G. performed the data analysis, M.G. and J.S. recruited and monitored subjects, A.M.N., J.A.M. and M.A.R. wrote the main manuscript text, which was then discussed and refined with the other authors.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Martinez-Nicolas, A., Guaita, M., Santamaría, J. et al. Ambulatory circadian monitoring in sleep disordered breathing patients and CPAP treatment. Sci Rep 11, 14711 (2021). https://doi.org/10.1038/s41598-021-94315-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-94315-0
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.