Introduction

The plasma volume (PV) status is a relevant factor when aiming to understand cardiovascular pathophysiology in heart failure patients who often feature a PV overload1,2,3. Guiding heart failure therapy based on direct assessment of volume status can reduce mortality and hospital readmissions due to decompensation in heart failure patients2.

Several methods are available to determine blood and plasma volume status in heart failure patients using indicator-dilution techniques based on iodine-labelled Albumin4 or carbon monoxide5. In compensated heart failure patients, direct measurement of the circulating blood volume allows the detection of a prognostically relevant blood volume expansion, which might otherwise not be recognised6. However, the methods measuring blood and plasma volume can be considered as elaborate and have thus not entered the clinical routine.

As an alternative to the direct measurement of plasma volume, several formulas, such as the Kaplan formula7 or the so-called Hakim formula8 have been proposed to calculate PV from anthropometric characteristics and the haematocrit, a laboratory parameter that is easily available. The resulting “estimated plasma volume” (ePV) has been widely applied when studying heart failure patients and general populations: The plasma volume status (PVS) based on ePV was shown to predict mortality in heart failure patients9, early cardiovascular events in heart failure after myocardial infarction10,11 and readmission to the hospital after recompensating of decompensated heart failure patients12,13. Even procedural outcome after transcatheter aortic valve implantation appears to be affected by the ePV excess on admission14. Recently, PVS was shown to be associated with cardiovascular morbidity and mortality in the general population15.

Whilst the PVS appears to be related to some echocardiographic and haemodynamic parameters16, analyses comparing ePV with the measured “true” PV in heart failure patients has only shown limited association between these parameters4,9. It was concluded that the prognostic ability of PVS concerning clinical outcomes of heart failure patients might be independent from directly reflecting the true PV status4.

Therefore, from our understanding, the key question is whether a true volume excess can be predicted by PVS on the individual level even when the estimated parameter does not precisely reflect the true volume status, e.g. because of systematic misalignment. Therefore, the aim of this study is to investigate the predictive properties of the calculated PVS based on the Hakim and the Kaplan formula in a group of compensated chronic heart failure patients.

Methods

Study design and subjects

The study population has been previously described in more detail17. In a cross-sectional design PV was determined in patients with known compensated systolic chronic heart failure and a left ventricular ejection fraction < 50%. 47 patients (10 women) were studied who were recruited from either the outpatient heart failure unit or the cardiology ward (if hospitalised for reasons other than cardiac decompensation). All subjects provided signed informed consent. Exclusion criteria were an acute decompensated state of heart failure (New York Heart Association (NYHA) Class IV), continuous oxygen therapy, haemodynamic instability, acute coronary syndrome, anaemia with a haemoglobin concentration ([Hb]) ≤ 8 g/dl, active bleeding, active malignancy, limited life expectancy < 1 year, noncardiac chronic renal disease, uncontrolled lung disease, chronic inflammatory disease and acute infection. All relevant associated patient data such as medication, functional status, echo and laboratory data were collected in the direct context of the clinic visit.

The study was designed in line with the latest revised form of the Declaration of Helsinki and was approved by the Ethics Committee of the Albert-Ludwigs-University Freiburg (31/14). The study is registered in the German registry for clinical studies (DRKS-ID: DRKS00006078, registered 09/05/2014).

Determination of plasma volume

The abbreviated CO-rebreathing method (aCORM), an indicator-dilution technique based on rebreathing of carbon monoxide (CO) as a tracer, was applied in all subjects to measure total haemoglobin mass (Hbmass)18. Intravascular volumes (red cell volume (RCV), PV and total blood volume (BV)) can then be quantified from aCORM using the following formulas19:

$$ {\text{RCV }} = {\text{ Hbmass }}/{\text{ MCHC }} \times {1}00, $$
$$ {\text{BV}} = {\text{RCV}} \times {1}00/{\text{Hct}}^{{1}} , $$
$$ {\text{PV }} = {\text{ BV }}{-}{\text{ RCV}}. $$

MCHC = mean corpuscular haemoglobin concentration, venous [Hb] and Hct were used for determination of MCHC. For RCV calculation, Hct was corrected to whole-body Hct by the factor 0.9120 (Hct1).

The calculation of true PV excess has been described previously in detail17. In brief, we based our analyses on the recommendation of the expert panel of the International Council for Standardization in Haematology (ICSH). The expected normal blood volumes were calculated according to the gender-specific ICSH formulae21. In a second step, ICSH estimates were compared with results from aCORM in healthy individuals, thereby normalising the results17 leading to an expected normal PV value which takes the application of aCORM into account. A normal volume of PV was then arbitrarily defined as ± 10% of the expected normal value. Consequently, PV excess is a PV > 10% of the expected normal value.

Estimation of plasma volume

The so-called Hakim8 formula and the Kaplan7 formulae were used to calculate estimated plasma volume (ePV_method)

$$ {\text{ePV}}\_{\text{Hakim }}\left( {\text{in ml}} \right) \, = \, \left( {{1} - {\text{haematocrit}}} \right) \, \times \, [{\text{a }} + \, \left( {{\text{b }} \times {\text{ body weight }}\left( {\text{in kg}} \right)} \right], $$

a = 1530 in males and 864 in females, and b = 41 in males and 47.9 in females.

$$ {\text{ePV}}\_{\text{Kaplan }}\left( {\text{in ml}} \right) \, = \, \left( {0.0{65 } \times {\text{ body weight }}\left( {\text{in kg}} \right)} \right) \, \times \, \left( {{1 } - {\text{ haematocrit}}} \right) \, \times { 1}000. $$

The ideal PV (iPV) is the normal expected PV calculated based on body weight and sex: iPV (in ml) = c × body weight (in kg).

c = 39 in males and 40 in females22. This formula is used as it has been applied in many studies evaluating PVS in order to use the same method despite other, more precise formulas exist21.

PVS illustrates whether the ePV_method deviates from iPV and is calculated as: PVS_method = [(ePV_method − iPV)/iPV] × 100%. Values > 100% indicate a higher-than-expected PVS_method.

Statistical analysis

Data for this study was managed using SAS JMP 9.0, statistical analyses were performed using R23. The predicted probabilities of PVS_method to identify subjects with true PV excess were calculated using logistic regression (GLM function, binomial fit). The receiver operator characteristics (ROC) for the respective PVS_method were calculated using the pROC package24. The optimal cut-off values of the ROC curve were found using the Youden index25. An alpha value of 0.05 was chosen for statistical significance.

Results

The subject characteristics are described in Table 1. As described previously17, true PV excess occurred in 23 subjects. The ROC analysis is depicted in Fig. 1. With an AUC of 0.65, PVS when calculated based on the so-called Hakim formula is a “poor”26 predictor of true PV excess assessed by the aCORM (best cut-off: − 16.5%; with a corresponding sensitivity of 0.78, a specificity of 0.54, a positive predictive value of 0.62, and a negative predictive value of 0.72). With an AUC of 0.72, PVS based on the Kaplan formula formally appears as an acceptable26 predictor of true PV excess (best cut-off value: − 6.3%; with a corresponding sensitivity of 0.87, a specificity of 0.58, a positive predictive value of 0.67, and a negative predictive value of 0.82).

Table 1 Baseline characteristics (n = 47) as in part previously published17.
Figure 1
figure 1

Area-under the curve for the prediction of true plasma volume excess by plasma volume status as calculated by the so-called Hakim formula (A) and the Kaplan formula (B).

Discussion

Recognition of blood volume excess is challenging as it might occur independent from physical signs of congestion but drives cardiovascular outcomes6. Our own observations in clinically compensated heart failure patients confirm the presence of considerable heterogeneity in the blood volume status17, which, on the other hand, appears to be relatively preserved over time on the individual level in stable patients, with PV changing 1.3% on average when measured repeatedly over the span of 6 months using the same method as it was applied here27. Furthermore, the typical measurement error for PV quantified by aCORM is between 3.8 and 4.7% when measured twice within a week in healthy subjects28. The heterogeneity of volume status imposes a diagnostical challenge when aiming to detect plasma volume excess but may also provide new options for management of heart failure patients: Measuring or estimating the circulating blood volume at different time points and the comparison of these changes with clinical indices and biomarkers in patients with chronic heart failure could be of clinical utility in terms of long-term management of this progressive chronic disease and evaluation of treatment effects.

Authors have previously studied the association between estimated PVS and echocardiographic and haemodynamic parameters related to congestive heart failure but reported heterogeneous results: Kobayashi et al. were able to establish a connection between estimated PVS and diastolic filling pressures and the E/E′ ratio in heart failure patients whilst vena cava width and ultrasonographic signs of congestions were unrelated to estimated PVS16.

To our knowledge, this is the first report to evaluate the predictive properties of the estimated PVS concerning the prediction of a ‘true’ measured PV excess in a cohort of patients with chronic heart failure. In our study, we could show that PVS calculated from the Kaplan formula based on anthropometric and hematologic data is an acceptable predictor of true PV excess whereas the so-called Hakim formula insufficiently predicts a true PV excess. However, while a ROC of 0.72 is formally considered as an “acceptable” predictive property26, this value is not acceptable in a clinical situation where higher odds than 72% are required to distinguish between a normal and a pathological status: our analyses concerning the positive predictive value of PVS_Kaplan show that one in three patients with a PVS >  − 6.3% (the best-cut off value) does not feature a true PV excess of > 10%.

In addition to the work presented by Fudim and Miller4, who could show that the agreement between measured and calculated values for PV is moderate at best, our data therefore illustrate that even when the calculated PVS is considered as a predictor for an individual’s PV excess and is used solely for this purpose, there is only limited clinical value of the parameter in this context.

This is remarkable from a (patho)physiological point of view given the predictive properties of the (estimated) PVS for cardiovascular outcomes9,10,12, which are unchallenged by our study. Apparently, PVS predicts cardiovascular outcomes, such as rehospitalisation, morbidity and mortality in patients stratified by this parameter whilst featuring only a modest connection to the true plasma volume of the individual patient. Therefore, patients that are identified as having an excess PVS by calculated parameters are not necessarily or exclusively those with a true PV excess.

Independent from an association with true PV, both, estimated PV and PVS could be considered as a compound risk predictor. When analysing the composition of estimated PV and PVS, it appears that the parameters depend on haematocrit, body weight and sex. At least haematocrit29 and sex30 have been shown to affect the cardiovascular prognosis. Moreover, when dry body weight is used to calculate the estimated PV by the so-called Hakim formula and, within the same mathematical approach, the ideal PV is calculated using normal body weight9, an indicator for body fat content is created, which might also predict cardiovascular prognosis31,32 and is associated with diastolic filling pressure33.

In this context, it is worth looking at the methodological history of the formula that has frequently been referred to as the Hakim-formula as it is mentioned in a book chapter written by Ismail et al.8. The formula, however, is based on much older work of Brown et al. and Wennesland et al. describing regression formulae for the total blood volume based on weight in women34 and men35 derived from blood volume measurements using 51Cr labelled erythrocytes. The term ‘1-haematocrit’ was added later to calculate the PV fraction from the total blood volume. This is, however, an oversimplification without taking the so called body-venous-haematocrit factor20 into account and thus, systematically underestimates PV. In this context, it is interesting that a minority of authors have applied the so-called Hakim formula using lean body weight4,12, as specifically recommended by Hakim, whereas others have applied the formula using the uncorrected raw body mass9,13,14,15,36 as it was intended in the original blood volume formula by Brown et al. and Wennesland et al.34,35. Efforts to validate the so-called Hakim Formula in heart failure patients unsurprisingly yielded only moderate correlation coefficients between ePV and measured PV with a systematic deviation of the formula in subjects with higher PV4,9. The work by Sprenger et al., taking deviations in haematocrit from the normal value into account, aims to overcome some of the drawbacks discussed above and also addresses the body-venous-haematocrit ratio37 and might be a more suitable approach to estimate PV, although this approach has not been validated in heart failure patients.

Concerning the ideal PVS, other, more elaborate algorithms predicting the expected normal PV based on body surface area and sex have been proposed before by the International Council for Standardization in Haematology to avoid body fat mass as a confounding variable21. This approach was also chosen by our group when calculating PV excess from PV measurements17, which is used as the reference parameter here.

In summary, these methodological aspects might further contribute to the predictive properties of the “calculated PVS” concerning cardiovascular outcomes and the relation to the diastolic filling pressures of the heart independent from predicting a true PV excess.

As discussed above, the haematocrit value affects prognosis of heart failure patients and is closely related to the PVS. Although this value is ubiquitously available, it could be considered more by the clinician and put in the overall context over time. Thus, it may be prudent to regard a decreasing haematocrit value of a patient as an indicator of PV excess. It still needs to be defined, if the possible consequence of increasing the dose of diuretics in such a case is sufficient and beneficial to the patient, especially in the light of the recently available inhibitors of sodium dependent glucose co-transporter 2.

Conclusion

Therefore, from our perspective and in agreement with Fudim and Miller4, we believe PVS as calculated from the formulas evaluated here should not be taken into account when aiming at decision making on the individual patient level concerning PV management. More work is necessary to clarify the origin of the predictive properties of calculated estimates of volume status for clinical outcomes of heart failure patients.