Abstract
Rheumatoid arthritis (RA) is characterised by painful, stiff and swollen joints. RA features sporadic ‘flares’ or inflammatory episodes—mostly occurring outside clinics—where symptoms worsen and plasma C-reactive protein (CRP) becomes elevated. Poor control of inflammation results in higher rates of irreversible joint damage, increased disability, and poorer quality of life. Flares need to be accurately identified and managed. A method comparison study was designed to assess agreement between CRP values obtained by dried blood spot (DBS) versus conventional venepuncture sampling. The ability of a weekly DBS sampling and CRP test regime to detect flare outside the clinic was also assessed. Matched venepuncture and finger lancet DBS samples were collected from n = 100 RA patients with active disease at baseline and 6 weeks (NCT02809547). A subset of n = 30 RA patients submitted weekly DBS samples over the study period. Patient demographics, including self-reported flares were recorded. DBS sample CRP measurements were made by enzyme-linked immunosorbent assay, and venepuncture samples by a reference immunoturbometric assay. Data was compared between sample types by Bland–Altman and weighted Deming regression analyses. Flare detection sensitivity and specificity were compared between ‘minimal’ baseline and 6 week sample CRP data and the ‘continuous’ weekly CRP data. Baseline DBS ELISA assay CRP measures yielded a mean positive bias of 2.693 ± 8.640 (95% limits of agreement − 14.24 to 19.63%), when compared to reference assay data. Deming regression revealed good agreement between the DBS ELISA method and reference assay data, with baseline data slope of 0.978 and intercept -0.153. The specificity of ‘continuous’ area under the curve (AUC) CRP data (72.7%) to identify flares, was greater than ‘minimal’ AUC CRP data (54.5%). This study indicates reasonable agreement between DBS and the reference method, especially at low to mid-range CRP values. Importantly, longitudinal CRP measurement in RA patients helps to clearly identify flare and thus could assist in remote monitoring strategies and may facilitate timely therapeutic intervention.
Trial registration: The Remote Arthritis Disease Activity MonitoR (RADAR) study was registered on 22/06/2016 at ClinicalTrials.gov Identifier: NCT02809547. https://clinicaltrials.gov/ct2/show/NCT02809547.
Similar content being viewed by others
Introduction
Rheumatoid arthritis (RA) is a debilitating and chronic inflammatory disease. RA is a characterised by sporadic synovitis, or ‘flares’ during which disease activity increases and joints become more painful and swollen1. These flares can lead to progressive and irreversible damage to joints, loss of musculoskeletal function and increased disability2. RA is also characterised by widespread systemic inflammation leading to general physical and mental impairment, with concomitant worsening of quality of life3. Monitoring of flares in disease activity by surrogate biological markers of inflammation is therefore important in RA, to identify individuals susceptible to joint destruction. Continuous monitoring during periods of active disease could also facilitate more accurate decisions on dosage of drugs and when to switch from ineffective treatments.
Inflammation in the synovium, or joint lining, correlates with systemic inflammatory responses in RA2,4. Acute phase immune response markers such as C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) are typically measured to record inflammation at the biological level and track response to therapy. ESR and CRP correlate with radiographic progression and they have been incorporated into disease activity composite scores such as DAS28, which is used clinically as a tool to assess treatment efficacy and target remission5,6.
Collection of blood samples from RA patients on a regular basis for the monitoring of inflammation markers presents unique challenges. Since blood collection currently requires trained personnel, patients either need to travel to outpatient clinics with significant costs and inconvenience, or qualified phlebotomists need to schedule home visits. However, during disease flare a patient’s mobility can be severely limited and home based health service models may not be available or cost effective, particularly for rural populations.
The Remote Arthritis Disease Activity MonitoR (RADAR) study was therefore designed to test the reliability of a blood sampling method with potential to address these challenges. Patients with active RA were equipped to provide dried-blood spots (DBS) from home and return the samples to a clinical laboratory by standard postal service. The potential for DBS samples to assist routine diagnosis and clinical assessment is well established7,8,9. Some blood biomarkers, including CRP, are stable in DBS for up to a week’s storage at ambient temperatures and even longer periods at − 80 °C10,11.
This study investigates how accurate CRP concentration measurements from DBS are compared to traditional whole blood samples in 100 RA patients with active disease. The purpose was to provide data on the reliability of DBS as a potential platform to continuously and remotely monitor RA patients. Importantly, the ability of a weekly DBS monitoring regime to detect disease flares was investigated in 30 of the RA patients during a 6 week follow up period. As such this is the first study to provide evidence of DBS CRP utility in an active RA population.
Methods
Participant recruitment
The research team at Ulster University collaborated with rheumatologists from the Western Health and Social Care Trust (WHSCT) to design, conduct and recruit patients to the study. One hundred patients identified using the following inclusion/exclusion criteria were recruited into the prospective observational cohort study: Remote Arthritis Disease Activity MonitoR (RADAR); ClinicalTrials.gov Identifier: NCT02809547. Inclusion criteria: aged between 18–90 years, diagnosed with RA (according to American College of Rheumatology criteria12), diagnosed with RA for a minimum of 1 year and maximum 10 year duration, active disease flares on a regular basis, and receiving a conventional (non-biologic) disease modifying anti-rheumatic drug (DMARD). Patient reported flare was defined as elevated stiffness and/ or pain in one or more joints lasting more than 24 h. Exclusion criteria: any other inflammatory conditions, any infections or trauma during study period, and have restricted hand function (determined by clinical team). Office for Research Ethics Committees Northern Ireland (ORECNI) (16/NI/0039), Ulster University Research Ethics Committee (UREC) (REC/16/0019) and WHSCT (WT/14/27) approvals were obtained for the study. All methods were performed in accordance with the relevant guidelines and regulations. Informed consent was obtained from all participants enrolled to the study.
Sample size calculations
A minimum sample size of 34 was required for 90% power, α = 0.05 and the ideal anticipated Cohen’s “d” effect size of 0.80, calculated using a two-sample t-test with SPSS ver. 25 (IBM Corp) integrated with R version 3.33. Thus, our sample size of 100 ensured adequate power to the study, in line with guidelines set by the Clinical and Laboratory Standards Institute EP09c-A313,14. Additionally, the sample number ensured that normal variation in CRP concentrations observed within an active disease RA cohort were recorded to analyse the precision of the sampling methods. The range ratio of reference method CRP concentrations across the cohort at the 6 week time point was 421 (126.5 mg/L high: 0.3 mg/L low).
Whole blood and DBS sample collection
Venepuncture whole blood samples collected as part of standard care were forwarded to the hospital laboratories for multiple tests including CRP. An additional 5 ml EDTA tube of blood and 5 finger lancet droplets of blood (approximately 10 μl each) were collected from all 100 RADAR study participants. Finger lancet blood droplets were deposited onto DBS Protein Saver 903™ cards (Whatman, GE Healthcare Life Sciences, Buckinghamshire, UK), pre-treated with a proprietary protein stabiliser coating. Both blood sample types were collected at study baseline and a 6 week follow up appointment at an outpatient rheumatology clinic for all participants. All patients received training in lancet and DBS card use at baseline and completed a Likert type questionnaire15, at the 6 week follow up appointment. Additionally a subcohort of 30 consenting participants were supplied with a kit containing sufficient DBS cards, finger lancets and pre-paid postal envelopes to provide weekly DBS from home during the 6 week follow up. Weekly DBS samples were dispatched to the NICSM laboratory by postal service in business reply envelopes, which contained a ziploc sealable biohazard pouch with silica gel desiccant. All DBS cards were logged on receipt and stored at − 80 °C until analysis. EDTA blood tubes were centrifuged on the day of collection at 5000 g, 500 ul plasma aliquots placed in autoclaved Eppendorf tubes and stored at – 80 °C until analysis.
Determination of CRP levels
Reference CRP concentration was quantified for whole blood samples (processed to plasma by centrifugation shortly after collection) using a high-sensitivity particle enhanced immunoturbidimetric assay run on a Cobas 8000 c701 system (LOD 0.15 mg/L; measuring range 0.3–20 mg/L; Roche Diagnostics, UK; dilutions and retests made on samples exceeding the assay range) at the Department of Biochemistry, Altnagelvin Hospital, UK (data subsequently referred to as ‘reference hospital’ in text or Ref Hosp in Figures). DBS were processed on the day of analysis by punching standardised 3 mm paper discs from the centre of each DBS sample into an Eppendorf tube, then rehydrated in 40 ul of 20 mM Tris–HCl (pH 7.5), 50 mM NaCl, with gentle agitation for 5 min at ambient room temperature (23 °C). The CRP concentration of DBS and plasma samples were determined in duplicate by a Quantikine enzyme‐linked immunosorbent assay (ELISA; LOD 0.022 ng/ml; measuring range 0.8–50 ng/ml) (R&D Systems Inc. Minneapolis, USA) along with quantitative controls (QC70) and standards. All assays and sample dilutions were performed according to manufacturers’ recommendations (data subsequently referred to as ‘DBS ELISA’ or DBS EL and ‘plasma ELISA’ or Plasma EL, respectively). ELISA plates were read at 450 nm with 540 nm wavelength correction on an Epoch microplate reader in NICSM (BioTek Instruments Inc., USA). The ELISA readings were converted to mg/L and for DBS eluent were corrected based on previous studies indicating that a standardised 3 mm filter paper disc could be saturated with 3.0 ul of blood16.
Statistical analysis
Parametric, two tailed student t-tests were performed comparing demographics (age and other numerical measures) between ‘flare’ and ‘no flare’ patient groups (Table 1). Gender distributions of the two groups were compared using two-sample proportion test. P value of < 0.05 was considered a statistically significant difference in all analyses.
Bland–Altman analysis (Fig. 2) and plots were used to compare paired sample CRP results, and findings are expressed as mean bias differences with 95% limits of agreement, using GraphPad Prism version 8.2.1. The plots with the 95% limits of agreement show the means of CRP values between each sample method plotted on the horizontal axis and differences between methods plotted on the vertical axis.
Weighted Deming regression was performed to estimate the systematic bias and its confidence interval between the reference whole blood and DBS or plasma CRP values, using NCSS Statistical Analysis and Graphics software version 19.0.3. Outliers, defined as points above or below the 95% limits of agreement on each Bland–Altman scatterplot were removed prior to Deming regression. Regression coefficients and predicted values were calculated using the formulas given in Linnet17. The standard errors of the regression coefficients and predicted values are calculated using the combined jackknife leave-one-out method (n − 2 degrees of freedom is used for the jackknife standard error estimates; Fig. 3E,F)18. The nonparametric Spearman correlation coefficients (r) were calculated with a two tailed test of significance.
In order to assess the sensitivity and specificity of DBS CRP to accurately detect disease flare, area under the curve (AUC) and change from baseline CRP metrics were calculated from the longitudinal data of the weekly DBS participant subcohort. CRP metrics were calculated by different methods (see Fig. 4): (i) by using all weekly data points to construct an accurate continuous data AUC value, or (ii) by using baseline and 6 week data points to estimate a minimal data AUC value or (iv) only assigned positive flare status if DBS CRP concentrations exceeded 10 mg/L. A threshold AUC value of 35 mg week/L (the mean value in patients reporting no flare) was used assign positive ‘flare’ status to (i) and (ii). A Mann–Whitney test was used to compare significance of any difference between metrics for flare and no flare subcohorts.
Ethics approval and consent to participate
Office for Research Ethics Committees Northern Ireland (ORECNI) (16/NI/0039), Ulster University Research Ethics Committee (UREC) (REC/16/0019) and WHSCT (WT/14/27) approvals were obtained for the study.
Consent for publication
Informed consent was obtained for all participants in the study, allowing for publication of anonymised clinical data.
Results
Patient demographics
Table 1 shows the demographic information of participants in the study grouped by the incidence of self-reported flares. The mean age of the study participants was 57.2 ± 12.6 years, with a mean disease duration of 6.0 ± 3.9 years. 67% of all participants reported flares during the 6 week study, with significantly higher mean baseline pain (on a visual analogue scale of 0–10019) reported in the ‘flare’ group, 55.4 ± 28.0, versus the ‘no flare’ group, 32.2 ± 28.1 (p = 0.0007). There was no significant difference in gender distributions between the two groups (p = 0.094). Both mean patient-global assessment (PGA)20,21 (‘flare’ 58.2 ± 26.1 vs. ‘no flare’ 39.3 ± 28.3; p = 0.0034) and mean DAS28-ESR22,23 (‘flare’ 3.9 ± 1.5 vs. ‘no flare’ 3.1 ± 1.4; p = 0.0251) were significantly higher in ‘flare’ subgroups at baseline. There was no statistically significant association between flare incidence and the duration of disease, baseline CRP or ESR (p > 0.05). Absolute changes in CRP or DAS28 over 6 weeks were not significantly different in participants who reported disease flare.
CRP assay data comparison
Baseline reference hospital immunoturbidimetry CRP concentrations of plasma samples have a similar median, 4.00 mg/L to paired DBS ELISA samples, 3.88 mg/L, though lower than the plasma ELISA median, 6.95 mg/L (Fig. 1A). Baseline measurement ranges for each assay were 55.80 mg/L, 25.42 mg/L and 38.61 mg/L, respectively. 6 week CRP median data was similar for reference hospital assay, 4.00 mg/L, DBS ELISA, 3.49 mg/L and plasma ELISA, 6.20 mg/L. 6 week measurement ranges for each assay were 126.20 mg/L, 48.25 mg/L, 37.63 mg/L, respectively (Fig. 1B).
Sample method comparison
Figure 2 shows the Bland–Altman plots, comparing CRP measurements from DBS ELISA and plasma ELISA to reference hospital assay data. Baseline DBS ELISA yielded slightly higher values with a mean positive bias of 2.693 ± 8.640 (95% limits of agreement − 14.24 to 19.63%; Fig. 2E). The 6 week DBS ELISA samples showed a similar positive bias of 2.331 ± 9.120 (95% limits of agreement − 15.54 to 20.21%). The plasma ELISA data indicate modest negative biases of − 0.080 ± 8.303 and − 1.094 ± 9.778 for baseline and 6 week samples, respectively. The Bland–Altman difference vs. average plots cone shaped distributions observed for both DBS and plasma indicate that the measurement error between the methods are proportional but not constant and that a weighted Deming regression approach was required. Deming regression revealed good agreement between the DBS ELISA method and the reference hospital assay (Fig. 3A,B) with baseline slope of 0.978 and intercept -0.153 and 6 week slope of 0.918 and intercept − 0.119 (Fig. 3E). Plasma ELISA did not agree with the reference hospital data with slopes of 1.496 and 1.525 observed for baseline and 6 week samples, respectively.
Flare detection during follow up
Area under the curve (AUC) values were used to assess whether the ‘continuous’ weekly DBS CRP readings influenced the sensitivity or specificity to correctly identify flare, compared to a typical clinical instance where ‘minimal’ baseline and 6 week data only were available (Table 2 and Fig. 4).
Neither method reached statistical significance. The specificity of continuous AUC data (72.7%) to identify flares, was greater than minimal AUC data (54.5%). Sensitivity was the same for both AUC metrics (52.9%). Sensitivity was increased (64.7%), although specificity was reduced (27.3%), when data above a clinically relevant threshold of 10 mg/L was considered. The positive predictive value or precision of the continuous AUC data (75%) was also improved, versus the minimal AUC data (64.3%). Negative predictive value was also greater for continuous data (50%) versus the minimal AUC data (42.9%).
Discussion
The central aim of this study was to establish if CRP values measured from DBS samples using an ELISA agree with those from a conventional plasma sample assayed by a hospital reference immunoturbidometric method. This is the first study exploring this approach in a rheumatoid arthritis population with active disease.
Method comparison
The Bland–Altman and Deming regression plots in this study show that there is reasonable agreement between the DBS and reference methodologies, especially in the low to mid-range CRP values. The calibration of the standard curve in ELISA does not cope as well with very high levels of CRP as the immunoturbidometric method does24. The majority of DBS ELISA measurements (91% in the baseline samples and 85% in the 6 week) lie between the limits of agreement lines (Fig. 2), indicating reasonable agreement between the two collection and assay methods. The weighted Deming regression coefficients for the values within the limits of agreement, which correct for systematic measurement error, indicate good agreement in particular between the DBS ELISA and reference methods.
The imperfect spearman correlation coefficients indicate a proportional error that might have originated from incomplete recovery of CRP in the ELISA methods, particularly with frozen plasma. The non-zero intercepts observed likely reflect a systematic error such as insufficient volume correction in DBS.
The normal probability plots (Supplementary Fig. 1) indicate how closely the two data sets agree, when the two cumulative distributions are plotted against each other, whilst also highlighting any skewness of the distribution. If the two measurements showed perfect agreement with each other, then the plotted data would fall on an ideal-diagonal line. The largest and most consistent skew was observed from the 75th percentile and above, therefore indicating that the higher CRP values measured by ELISA did not show good agreement with the immunoturbidimetry data.
Flare detection
Our data does not suggest that rises in CRP alone can predict an impending flare in RA patients, but that longitudinal CRP measures can help to confirm biochemical evidence of a flare which can be used by clinicians alongside clinical measures such as tender and swollen joint counts. Continuous weekly CRP data, collected while study participants were at home, was able to identify flare with greater specificity, than minimal data taken at baseline and follow up hospital appointments. The occurrence of flares often prompts an escalation in therapy25. In the current study, 16.4% of patients who experienced flare had a change in treatment (addition or removal) and 6% had treatment dose modified at 6 weeks. Whereas in those without flare, 4.5% had a change in treatment and 9% a dose modification. With further sample and analytical refinement, a DBS approach could offer new opportunities to optimally suppress chronic inflammatory episodes, and reduce long term morbidity and mortality risk to people with RA.
Clinical implications
The decision to treat inflammation in RA can be initiated when mean changes in CRP of 3 mg/L or more distinguish active flare26. Thus, changes in higher plasma CRP concentrations beyond the capability of the ELISA method should not adversely influence the course of treatment.
If a clinician were to attempt to identify active flares using a DBS CRP assay, the 95% limits of agreement (using 6 week Bland–Altman parameters) between the two methods at the active disease cut-off of 10 mg/L would be 8.45–12.02 mg/L27,28. This could be tolerable from a clinical perspective as the variance observed for reference readings below 20–25 mg/L is not appreciable and the positive bias shown with DBS sample readings may compensate to some degree for under measurement. Though the imprecision may mean a small number of patients with borderline flare may be overlooked, it would still allow patients with active disease clearly above a 10 mg/ml CRP threshold to be accurately identified.
Limitations
The agreement between DBS and reference methods was acceptable with CRP concentrations in the low to mid-range, but DBS CRP readings for samples with reference values above 25 mg/L were imprecise, with increased variance beyond the 95% confidence limits. It is possible that the use of ELISA assays may have caused a systematic bias, as both ELISA assays showed imprecision with higher levels of CRP. Another potential source of error with DBS samples is changes in haematocrit due to inaccurate volume correction estimates, though dried plasma solutions may mitigate against this29,30,31. It is also likely that using the patient’s subjective ‘self-report’ of flare will not always distinguish an inflammatory flare from an increase of pain due to other causes. However, a recent study comparing patient and clinician reported flares indicates close agreement across 79–93% of joints, particularly on swollen joints32.
Conclusions
The good agreement indicated between DBS and the reference method at low to mid-range CRP could pave the way for development of self-sampling blood collection devices as part of novel remote monitoring services available to individuals living with chronic diseases such as rheumatoid arthritis.
Data availability
The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- RA:
-
Rheumatoid arthritis
- CRP:
-
C-reactive protein
- DBS:
-
Dried blood spot
- ELISA:
-
Enzyme linked immunosorbent assay
- ESR:
-
Erythrocyte sedimentation rate
- DAS28:
-
Disease activity score across 28 joints
- WHSCT:
-
Western Health and Social Care Trust
- RADAR:
-
Remote Arthritis Disease Activity MonitoR
- DMARD:
-
Disease modifying anti-rheumatic drug
- ORECNI:
-
Office for Research Ethics Committees Northern Ireland
- UREC:
-
Ulster University Research Ethics Committee
- NICSM:
-
Northern Ireland Centre for Stratified Medicine
- AUC:
-
Area under the curve
- T0:
-
Baseline time point
- T6:
-
6 Week time point
References
Bingham, C. O. 3rd. et al. Developing a standardized definition for disease “flare” in rheumatoid arthritis (omeract 9 special interest group). J. Rheumatol. 36, 2335–2341 (2009).
Smolen, J. S. et al. Rheumatoid arthritis. Nat. Rev. Dis. Primers 4, 18001 (2018).
Xavier, R. M. et al. Burden of rheumatoid arthritis on patients’ work productivity and quality of life. Adv. Rheumatol. 59, 47–48 (2019).
Alam, J., Jantan, I. & Bukhari, S. N. A. Rheumatoid arthritis: recent advances on its etiology, role of cytokines and pharmacotherapy. Biomed. Pharmacother. 92, 615–633 (2017).
Van Der Heijde, D. M. et al. Judging disease activity in clinical practice in rheumatoid arthritis: first step in the development of a disease activity score. Ann. Rheum. Dis. 49, 916–920 (1990).
Van Der Heijde, D. M., Van’T Hof, M., Van Riel, P. L. & Van De Putte, L. B. Validity of single variables and indices to measure disease activity in rheumatoid arthritis. J. Rheumatol. 20, 538–541 (1993).
Edelbroek, P. M., Van Der Heijden, J. & Stolk, L. M. Dried blood spot methods in therapeutic drug monitoring: methods, assays and pitfalls. Ther. Drug Monit. 31, 327–336 (2009).
Mcdade, T. W., Williams, S. & Snodgrass, J. J. What a drop can do: dried blood spots as a minimally invasive method for integrating biomarkers into population-based research. Demography 44, 899–925 (2007).
Lakshmy, R., Gupta, R., Prabhakaran, D., Snehi, U. & Reddy, K. S. Utility of dried blood spots for measurement of cholesterol and triglycerides in a surveillance study. J. Diabetes Sci. Technol. 4, 258–262 (2010).
Palmer, O. M. P. et al. Effects of transport temperature on the stability of inflammatory, hemostasis, endothelial function, and oxidative stress plasma biomarker concentrations. Shock 47, 715–719 (2017).
Jansen, E., Beekhof, P., Viezeliene, D., Muzakova, V. & Skalicky, J. Long-term stability of cancer biomarkers in human serum: biomarkers of oxidative stress and redox status, homocysteine, crp and the enzymes Alt And Ggt. Biomark. Med. 9, 425–432 (2015).
Aletaha, D. et al. Rheumatoid arthritis classification criteria: an american college of rheumatology/european league against rheumatism collaborative initiative. Arthritis Rheum. 62, 2569–2581 (2010).
Budd, J. R. et al. In Clsi Guideline Ep09c (Ed Clinical And Laboratory Standards Institute, (Clsi)) 1–11 (CLSI, Wayne, Pa, 2018).
Linnet, K. Necessary sample size for method comparison studies based on regression analysis. Clin. Chem. 45, 882–894 (1999).
Van Alphen, A., Halfens, R., Hasman, A. & Imbos, T. Likert or rasch? Nothing is more applicable than good theory. J. Adv. Nurs. 20, 196–201 (1994).
Hewawasam, E., Liu, G., Jeffery, D. W., Gibson, R. A. & Muhlhausler, B. S. Estimation of the volume of blood in a small disc punched from a dried blood spot card. Eur. J. Lipid Sci. Technol. 120, 1700362 (2018).
Linnet, K. Estimation of the linear relationship between the measurements of two methods with proportional errors. Stat. Med. 9, 1463–1473 (1990).
Cameron, A. C. & Trivedi, P. K. Microeconometrics: Methods and Applications 1056 (Cambridge University Press, New York, 2005).
Massy-Westropp, N., Ahern, M. & Krishnan, J. A visual analogue scale for assessment of the impact of rheumatoid arthritis in the hand: validity and repeatability. J. Hand Ther. 18, 30–33 (2005).
Scott, P. J. & Huskisson, E. C. Measurement of functional capacity with visual analogue scales. Rheumatol. Rehabil. 16, 257–259 (1977).
Nikiphorou, E. et al. Patient global assessment in measuring disease activity in rheumatoid arthritis: a review of the literature. Arthritis Res. Ther. 18, 251–256 (2016).
Van Riel, P. L. The development of the disease activity score (Das) and the disease activity score using 28 joint counts (Das28). Clin. Exp. Rheumatol. 32, S-74 (2014).
Fransen, J. & Van Riel, P. L. The disease activity score and the eular response criteria. Rheum. Dis. Clin. North Am. 35, 745–Viii (2009).
Sanchez, A. et al. Evaluation of an improved immunoturbidimetic assay for serum c-reactive protein on a cobas integra 400 analyzer. Clin. Lab. 48, 313–317 (2002).
Markusse, I. M. et al. Disease flares in rheumatoid arthritis are associated with joint damage progression and disability: 10-year results from the best study. Arthritis Res. Ther. 17, 232–242 (2015).
Bykerk, V. P. et al. Identifying flares in rheumatoid arthritis: reliability and construct validation of the Omeract Ra flare core domain set. Rmd Open 2, E000225-000225 (2016).
Felson, D. T. et al. American college of rheumatology/european league against rheumatism provisional definition of remission in rheumatoid arthritis for clinical trials. Ann. Rheum. Dis. 70, 404–413 (2011).
Twomey, P. J. & Kroll, M. H. How to use linear regression and correlation in quantitative method comparison studies. Int. J. Clin. Pract. 62, 529–538 (2008).
Deprez, S., Paniagua-Gonzalez, L., Velghe, S. & Stove, C. P. Evaluation of the performance and hematocrit independence of the hemapen as a volumetric dried blood spot collection device. Anal. Chem. 91, 14467–14475 (2019).
Carmona, S., Seiverth, B., Magubane, D., Hans, L. & Hoppler, M. Separation of plasma from whole blood by use of the cobas plasma separation card: a compelling alternative to dried blood spots for quantification of hiv-1 viral load. J. Clin. Microbiol. 57, E01336-E1418 (2019).
Velghe, S., Delahaye, L. & Stove, C. P. Is the hematocrit still an issue in quantitative dried blood spot analysis?. J. Pharm. Biomed. Anal. 163, 188–196 (2019).
Kuettel, D. et al. Flares in rheumatoid arthritis: do patient-reported swollen and tender joints match clinical and ultrasonography findings?. Rheumatology (Oxford) 59, 129–136 (2020).
Acknowledgements
DG acknowledges assistance from Patricia Connolly (Cardiac Assessment Unit, Western Health and Social Care Trust, Omagh, UK) in recruitment of study participants.
Funding
DSG wishes to acknowledge funding from the Research and Development Office, Health and Social Care NI, The Northern Ireland Rheumatism Trust and Invest Northern Ireland in support of this work.
Author information
Authors and Affiliations
Contributions
D.G., P.G., S.Z. made substantial contributions to the conception and design of the study; D.G., L.D., K.M., K.T., D.S., P.G., C.C. contributed to the acquisition of data, P.S., L.D. and S.Z. data analysis, D.G., P.G., S.Z. interpretation of data; D.G., S.Z., L.D. and P.G. drafted the work and all authors have revised and approved the submitted version.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
D’Cruz, L.G., McEleney, K.G., Cochrane, C. et al. Assessment of a dried blood spot C-reactive protein method to identify disease flares in rheumatoid arthritis patients. Sci Rep 10, 21089 (2020). https://doi.org/10.1038/s41598-020-77826-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-77826-0
This article is cited by
-
Analysis of C-reactive protein from finger stick dried blood spot to predict high risk of cardiovascular disease
Scientific Reports (2023)
-
Digitally-supported patient-centered asynchronous outpatient follow-up in rheumatoid arthritis - an explorative qualitative study
BMC Health Services Research (2022)
-
Remote sampling of biomarkers of inflammation with linked patient generated health data in patients with rheumatic and musculoskeletal diseases: an Ecological Momentary Assessment feasibility study
BMC Musculoskeletal Disorders (2022)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.