Abstract
Elasticity is one basic property of hybrid organic-inorganic perovskites. It highly relates to many fundamental processes in solid physics. The investigation of elasticity is of interest not only to explore the intrinsic properties of a material, but also to improve their potential application performance. In this study, we predict photoacoustic eigen-spectrum (PAES) of single crystal. Then by solving the inverse problem of the generation of PAES, we propose a noncontact method to determine a complete set of elastic constants of single crystal in one test. Experiments confirm the proposed method accurately determines all elastic constants of MAPbBr3. Since this method is totally noncontact and does not require multiple specimens cutting along different crystal axes, it could be more competent for rare, tiny and brittle specimen, or when the specimen is immersed in turbid or opaque medium. Benefitting from these superiorities, the proposed method might be found prominent values in materials science and applications.
Similar content being viewed by others
Introduction
Hybrid organic-inorganic perovskites (HOIPs) are one of the most promising photovoltaic materials, benefitting from their high charge carrier motilities, low temperature solution process, long charge carrier diffusion lengths, superb optical absorption across the visible spectrum, and high photoelectric conversion efficiency1,2,3,4,5. Elasticity is one important property of HOIPs, which is associated with many fundamental processes in solid physics, including lattice dynamics, phonon spectra, thermal expansion, Debye temperature and Grüneisen constant6. Therefore, the investigation of elasticity is of interest not only to explore the intrinsic properties of a material, but also to improve their potential application performance7,8,9,10.
Many works have been done to predict or measure the elasticity of HOIPs. The first principle was used to theoretically calculate the elastic constants according to the equation for the interatomic potential7. Inelastic neutron scattering spectroscopy (INS) and Brillouin light scattering (BS)11,12 have been applied to measure the elasticity of HOIPs. These methods detect the scanning scattering energy, extract the speed of sound in different directions, then derivate the elastic constants. Whereas, these methods often need multiple specimens and to cut samples in different directions. Resonant ultrasonic spectroscopy (RUS) was also applied to evaluate the elasticity of HOIPs with a direct-contact excitation of the eigen-vibrations of the specimen8,13,14,15,16,17,18. Non-contact resonant ultrasonic spectroscopy techniques use pulse laser to excite vibrations, and detect the surface displacement of the sample by using optical method19,20,21. This method could be restricted by the surface condition and shape of the specimen, and environmental medium. Whereas, a more applicable method is still demanded for exploring the elasticity of perovskites.
In this study, we report a noncontact method, to evaluate all elastic constants of a cubic phase crystal, based on the photoacoustic eigen-spectrum (PAES). Based on photoacoustic effect there are powerful technologies for imaging in opaque medium, which open up great prospects for biomedicine22,23,24,25,26,27. Our previous study revealed that photoacoustic signals from isotropic spherical and cylindrical elastomer contain the eigen-vibration information28,29. PAES are the components in photoacoustic signals corresponding to the eigen-vibration of the elastomer. In this study, we solve the forward problem of predicting PAES according to the elastic constants, and demonstrate its general numerical solution of a single crystal. Then, we study the inverse problem and evaluate the elastic constants from the measured eigen-spectrum. Finally, the method is applied to measure all elastic constants of HOIPs.
Results
Extraction of photoacoustic eigen-spectrum
Figure 1 shows one typical waveform and spectrum of the photoacoustic signals detected from the specimen No. 2. As shown in Fig. 1, strong signals are generated from the specimen under the illumination of a pulse laser. Although the laser pulse is extremely narrow (8~10 ns), the ultrasound emission from the specimen last a long time (>50 µs). For the long-duration coda wave, its waveform is periodic and its amplitude is attenuated. The amplitude attenuation results from the ultrasound irradiation, which brings vibratory energy away. The periodicity corresponds to the eigen-vibration modes of the specimen. These characteristics of the signal can be confirmed in the time-frequency map, as show in Fig. 1(b). A lot of spectral lines appear in the time-frequency spectrum of the photoacoustic signals, which imply the periodic vibration of the specimen. Each spectral line corresponds to one eigen-vibration. Figure 1(c) plots the normalized power spectral density of the signals. The frequencies of eigen-vibrations can be precisely extracted from these narrow spectral peaks.
Elastic constants derived from PAES
The elastic constants can be estimated from the measured eigenfrequencies by solving the inverse problem. Figure 2 shows the convergence procedure of elastic constants estimation, where Fig. 2(a–c) are the deviation functions in C11-C12 space, C11-C44 space, and C12-C44 space, respectively. Here, the deviation function is defined in Eq. (2). The measured frequencies fim are extracted from the photoacoustic spectrum as shown in Fig. 1. The predicted eigenfrequencies \({f}_{i}^{c}\)(x) are calculated by solving Eq. (1) with the elastic constants given by the x-axis and y-axis. The color represents the frequency offset between the prediction values and the measured frequencies. The initial values to predict the eigenfrequencies are set as x = [C11, C12, C44] = [45 GPa, 30 GPa, 2 GPa]. Initially, the predicted frequencies are far away from the measured frequencies F(x0) = 0.63414, since the preset parameters do not match the accurate elastic constants of the specimen. Then, we optimize the elastic constants by solving the inverse problem. The empty dots in Fig. 2 show the convergence process of approaching the best-fitting parameters. After 10 times of iterations, the parameters are converged at xopt = [C11, C12, C44] = [30.63 GPa, 11.6 GPa, 3.63 GPa] and the deviation function is reduced to F(xopt) = 0.001. It is seen that the parameters arrive at the valley of the deviation function, as shown by the stars in Fig. 2. The predicted frequencies match the measurements best. The optimized parameters xopt measure the elastic constants of the specimen.
Figure 3 illustrates the results of elasticity evaluation. Figure 3(a) shows the measured frequencies \({f}_{i}^{m}\) against the predicted eigen-frequencies \({f}_{i}^{c}\)(xopt) for seven specimens. All frequencies agree with each other very well after solving the inverse problem. The optimized parameters xopt can accurately predict the eigen-vibration of specimens, in other words, xopt precisely measure elasticity of specimens. Figure 3(b) presents the measured elastic constants C11 = 30.7 ± 2.46 GPa, C12 = 10.53 ± 1.62 GPa, and C44 = 3.51 ± 0.11 GPa of MAPbBr3, and error bars indicate standard deviation of multiple measurements. The results agree with measurements by laser ultrasonic(LU), INS and BS method, reported in the previous studies, as shown in Table 1 11,12,30. Moreover, the measurements of seven specimens have good consistency. The proposed noncontact method measures all elastic constants of MAPbBr3.
Discussion
In summary, we have predicted the PAES of a single crystal. Then by solving the inverse problem of the generation of PAES, we proposed a noncontact method to determine a full set of elastic constants of MAPbBr3 from the detected PAES in one test. In comparison to other methods used for the measurement of elastic constants, PAES has its own unique advantages. Firstly, PAES is totally noncontact, whether the vibration generation or the signal detection. The specimen is only simply immersed in liquid. In contact RUS system, the specimen need to be clamped by transducers with an additional force. Therefore, PAES could be applicable for brittle materials and tiny specimen. Secondly, it can probe all elastic constants of the specimen in one test. INS and BS method require multiple specimens cutting along different crystal axes. These merits make PAES method be more competent for rare specimen. Thirdly, PAES is also different from laser ultrasound that it detects the photoacoustic wave emitted from the vibrating specimen, instead of directly measuring the vibrational surface of the specimen. This method is still available when the specimen is immersed in turbid or opaque medium. Benefitting from these characteristics (or superiorities), PAES might be found valuable in some practical applications, including a precise evaluation of elasticity of tiny rare specimen, online monitoring the elastic constants during the growth process of a crystal in solutions, and testing elasticity of materials implanted in biological tissue, etc. There are also some limitations of PAES. Firstly, soft elastomer could have very low eigen-frequencies, which may be difficult to excite its vibration and detect PA eigen-spectral signals. Secondly, if specimen has big damping factor, eigen vibrations will attenuate quickly and few frequencies could be extracted. Therefore, a high quality factor of the specimen is required. Finally, the proposed method is operated in liquid, a suitable medium is required to avoid dissolution or other chemical reactions between the specimen and medium. To extract elastic constants precisely, we can enhance intensity of PA signals by increasing laser fluence and choosing laser wavelength with high light absorption. Besides, an accurate measurement of size is always important when irregularly shaped specimen is tested. Along with improving technical details, this method would be applied to more materials.
Methods
Measurement system
Figure 4(a) gives the experimental setup. The specimen was stored in a beaker and immersed in dodecane. Since the specimen contacts was freely placed in the beaker and no additional force was applied on them, the free boundary condition is approximately satisfied. A Q-switched Nd: YAG laser with a wavelength of 532 nm and a pulse width of about 8~10 ns was used to illuminate the specimen and generate photoacoustic signals. Light absorption of MAPbBr3 starts from about 570 nm and has strong optical absorption at 532 nm31. Based on rough prior knowledge of specimen, it can be estimated that the eigen-frequencies of the specimen are about from 0.2 MHz to 5 MHz. An ultrasound transducer (V310, Panametrics) with a central frequency of 4.39 MHz and a relative bandwidth of 100.1% at −6 dB was immersed into dodecane in the beaker to receive the photoacoustic signals. This transducer has enough wide bandwidth to cover the main frequency range of the PA signals of specimens. The detected signals were amplified 46 dB (SA-230F5, NF) and sampled by a data acquisition board (PCI-5105, NI) with a frequency of 30 MHz. For each specimen, the measurement was repeated 200 times and averaged to reduce noise. Figure 4(b) is the photograph of seven specimens of MAPbBr3 measured in the experiment which are prepared by the inverse temperature crystallization method31,32. Equimolar mixture of the CH3NH3Br and PbBr2 were dissolved in dimethylformamide (DMF) to obtain a 1 mol/L solution of CH3NH3PbBr3. The above solution was heated and kept at 80 °C for several hours, then large number of small crystals can be readily harvested. For the sake of convenience, they are numbered from 1 to 7. Their sizes were measured and given in Table 2. The volume of the smallest specimen (No. 6) is only 0.5735 mm3 and the biggest one (No. 5) is 15.9 mm3. Density is 3.8 g/cm3 used in this study.
Process of drawing time-frequency map
Time-frequency map could be calculated and drawn by the short-time Fourier transform: At the sample rate of 30 MHz, the window length and overlap size of Fourier transform are 360 and 350 separately which means time-moving step is 0.33 µs. The window type is Hanning. When drawing the time-frequency map, we use the timeline as horizontal coordinate and frequency as ordinate. Colors represent relative strength of the energy spectrum density.
PAES prediction of elastomer
Let’s consider an elastic specimen exposed to a pulsed laser. The specimen would absorb optical energy, arise transient thermoelastic expansion, and emit wideband ultrasound to the surrounding media. This is the so-called photoacoustic effect. As pulsed laser illumination ceases, the elastomer will keep free-vibrating and emitting ultrasound for a period of time, because of its elasticity and inertance. In this stage, the frequencies of free vibrations are the eigenfrequencies of the elastomer. Moreover, the emitted ultrasound has the same frequencies as the vibrations of the elastomer. Therefore, the PAES can be predicted by analyzing eigen-vibrations of the elastomer.
Considering an elastomer with free boundaries, its eigen vibration obeys the following matrix eigenvalue equation33
where ρ is the density, the components of the vector a = [aiλ] are eigen vector consists of the expansion coefficients of displacement ui = ∑aiλΦλ which is expanded in a suitable set of basis functions Φλ, and the eigenvalues correspond to the eigen frequencies f. E and Γ are matrices whose elements are Eλiλ′i′ = δii′∫ΦλΦλ′dV, Γλiλ′i′ = Ciji′j′∫Φλ,jΦλ′,j′dV respectively. Ciji′j′ is the elastic tensor and subscript indices following a comma denotes differentiation with respect to that coordinate. The forward problem of PAES generation can be solved from Eq. (1), that is, the PAES of elastomer can be predicted with the given elastic constants.
Inversion of elastic constants
If the PAES is detected, elastic constants could be estimated by solving the inverse problem, that is, to search a set of optimized elastic constants xopt = [Cij] to minimize the deviation function16,17
where \({f}_{i}^{m}\) refers to the i-th measured frequencies and \({f}_{i}^{c}\)(x) are the eigen-frequencies predicted by solving Eq. (1) with the elastic constants x = [Cij]. ωi = 1/\({({f}_{i}^{m})}^{2}\) is the weighting factor and M is the number of eigenfrequencies used for solving the inverse problem. The parameters to minimize the deviation function Eq. (2) can be determined by using a Levenberg-Marquardt algorithm34,35,36
xn is the parameter vector after n-th iteration, h(x) = [h1(x) h2(x) … hM(x)]T with hi(x) = [\({f}_{i}^{c}({\bf{x}})-{f}_{i}^{m}\)]/\({f}_{i}^{m}\) is the deviation vector, J = dh/dx is Jacobian matrix, and α is a nonnegative damping factor. With the given initial x0 and α, we can predict eigenfrequencies and calculate the first x1 according to Eqs. (2–3). With the calculated x1 the next iteration is repeated. Finally, x converges at its optimized value, which makes F(x) reach the minimum value. The inverse problem is solved and xopt is the estimated elastic constants.
Verification of PAES
Four spherical isotropic particles made of polystyrene divinylbenzene (PSDVB), stannum (Sn), brass (Brs), and steel (Stl) with known elasticity parameters are used to verify the accuracy of PAES. Figure 5 shows the estimated elastic constants values match the actual values very well. Zener anisotropy index A = 2C44/(C11-C12)37 of PSDVB, Sn, Brs, Stl are 0.87, 1.00, 1.07, 1.06 respectively that exhibit an elastic isotropic nature. The result confirms the accuracy of PAES method in elasticity measurement of isotropic materials.
Based on the verification of PAES, we proposed a noncontact method to measure the elasticity of the relevant member in HOIPs, named as MAPbBr3 that has 3 independent elastic constants x = [C11 C12 C44] in the cubic phase. A 2d1 × 2d2 × 2d3 rectangular shaped specimen is illuminated by a pulse laser and the generated photoacoustic signals are detected. Since the photoacoustic signals contain the same frequencies as the eigen-vibrations of the specimen. The elastic constants of the specimen can be evaluated by the above inverse problem.
Data availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Stranks, S. D. et al. Electron-Hole Diffusion Lengths Exceeding 1 Micrometer in an Organometal Trihalide Perovskite Absorber. Science 342, 341–344 (2013).
Park, N.-G. Organometal Perovskite Light Absorbers Toward a 20% Efficiency Low-Cost Solid-State Mesoscopic Solar Cell. J. Phys. Chem. Lett. 4, 2423–2429 (2013).
Kojima, A., Teshima, K., Shirai, Y. & Miyasaka, T. Organometal Halide Perovskites as Visible-Light Sensitizers for Photovoltaic Cells. J. Am. Chem. Soc. 131, 6050–6051 (2009).
Liu, Y. & Yang, Z. Recent Progress in Single-Crystalline Perovskite Research Including Crystal Preparation, Property Evaluation, and Applications. Adv. Sci. 5, 1700471 (2018).
Priante, D. et al. The recombination mechanisms leading to amplified spontaneous emission at the true-green wavelength in CH3NH3PbBr3 perovskites. Appl. Phys. Lett. 106, 081902 (2015).
Kittel, C. Introduction to Solid State Physics. (Wiley, 2005).
Feng, J. Mechanical properties of hybrid organic-inorganic CH3NH3BX3 (B = Sn, Pb; X = Br, I) perovskites for solar cell absorbers. APL Mater. 2, 081801 (2014).
Migliori, A. et al. Resonant ultrasound spectroscopic techniques for measurement of the elastic moduli of solids. Phys. B Condens. Matter 183, 1–24 (1993).
Rakita, Y., Cohen, S. R., Kedem, N. K., Hodes, G. & Cahen, D. Mechanical properties of APbX3 (A = Cs or CH3NH3; X = I or Br) perovskite single crystals. MRS Commun. 5, 623–629 (2015).
Ćirić, L. et al. Mechanical response of CH3NH3PbI3 nanowires. Appl. Phys. Lett. 112, 111901 (2018).
Ferreira, A. C. et al. Elastic Softness of Hybrid Lead Halide Perovskites. Phys. Rev. Lett. 121, 085502 (2018).
Létoublon, A. et al. Elastic Constants, Optical Phonons, and Molecular Relaxations in the High Temperature Plastic Phase of the CH3NH3PbBr3 Hybrid Perovskite. J. Phys. Chem. Lett. 7, 3776–3784 (2016).
Ohno, I. Free vibration of a rectangular parallelepiped crystal and its application to determination of elastic constants of orthorhombic crystals. J. Phys. Earth 24, 355–379 (1976).
Li, G. & Gladden, J. R. High Temperature Resonant Ultrasound Spectroscopy: A Review. Int. J. Spectrosc. 2010, 1–13 (2010).
Leisure, R. G. & Willis, F. A. Resonant ultrasound spectroscopy. J. Phys. Condens. Matter 9, 6001 (1997).
Tang, L. & Cao, W. Temperature dependence of self-consistent full matrix material constants of lead zirconate titanate ceramics. Appl. Phys. Lett. 106, 052902 (2015).
Tang, L., Tian, H., Zhang, Y. & Cao, W. Temperature dependence of dielectric, elastic, and piezoelectric constants of [001]c poled Mn-doped 0.24Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal. Appl. Phys. Lett. 108, 082901 (2016).
Chen, C., Liu, S., Tan, X., Tang, L. & Cao, W. Accurate characterization of complete set constants of single domain 0.72Pb(Mg1/3Nb2/3)O3–0.28PbTiO3 single crystal by resonant ultrasound spectroscopy using only one sample. J. Appl. Phys. 125, 064102 (2019).
Sedlák, P., Landa, M., Seiner, H. & Bicanová, L. Non-Contact Resonant Ultrasound Spectroscopy for Elastic Constants Measurement. In: 1st International Symposium on Laser Ultrasonics: Science, Technology and Applications, Montreal, Canada; 6 (2008).
Ogi, H., Sato, K., Asada, T. & Hirao, M. Complete mode identification for resonance ultrasound spectroscopy. J. Acoust. Soc. Am. 112, 2553–2557 (2002).
Seiner, H., Růžek, M., Sedlák, P., Bicanová, L. & Landa, M. Resonant ultrasound spectroscopy for investigation of thin surface coatings. In 237–248, https://doi.org/10.2495/MC090231 (2009).
Yao, L., Xi, L. & Jiang, H. Photoacoustic computed microscopy. Sci. Rep. 4, 4960 (2015).
Qi, W., Jin, T., Rong, J., Jiang, H. & Xi, L. Inverted multiscale optical resolution photoacoustic microscopy. J. Biophotonics 10, 1580–1585 (2017).
Xi, L. & Jiang, H. Integrated photoacoustic and diffuse optical tomography system for imaging of human finger joints in vivo. J. Biophotonics 9, 213–217 (2016).
Li, X., Heldermon, C. D., Yao, L., Xi, L. & Jiang, H. High resolution functional photoacoustic tomography of breast cancer: High resolution fPAT of breast cancer. Med. Phys. 42, 5321–5328 (2015).
Xu, M. & Wang, L. V. Photoacoustic imaging in biomedicine. Rev. Sci. Instrum. 77, 041101 (2006).
Wang, L. V. Multiscale photoacoustic microscopy and computed tomography. Nat. Photonics 3, 503–509 (2009).
Gao, X., Tao, C., Liu, X. & Wang, X. Photoacoustic eigen-spectrum from light-absorbing microspheres and its application in noncontact elasticity evaluation. Appl. Phys. Lett. 110, 054101 (2017).
Gao, X., Tao, C., Zhu, R. & Liu, X. Noninvasive low-cycle fatigue characterization at high depth with photoacoustic eigen-spectrum analysis. Sci. Rep. 8, 7751 (2018).
Lomonosov, A. M. et al. Exceptional elastic anisotropy of hybrid organic-inorganic perovskite CH3NH3PbBr3 measured by laser ultrasonic technique. Phys. Status Solidi RRL - Rapid Res. Lett. 10, 606–612 (2016).
Liu, Y. et al. Two-Inch-Sized Perovskite CH3NH3Pb3 (X = Cl, Br, I) Crystals: Growth and Characterization. Adv. Mater. 27, 5176–5183 (2015).
Saidaminov, M. I. et al. High-quality bulk hybrid perovskite single crystals within minutes by inverse temperature crystallization. Nat. Commun. 6, 7586 (2015).
Visscher, W. M., Migliori, A., Bell, T. M. & Reinert, R. A. On the Normal Modes of Free Vibration of Inhomogeneous and Anisotropic Elastic Objects. J. Acoust. Soc. Am. 90, 2154–2162 (1991).
Ranganathan, A. The Levenberg-Marquardt Algorithm. Tutoral LM Algorithm 11, 101–110 (2004).
Levenberg, K. A method for the solution of certain non-linear problems in least squares. Q. Appl. Math. 2, 164–168 (1944).
Marquardt, D. W. An Algorithm for Least-Squares Estimation of Nonlinear Parameters. J. Soc. Ind. Appl. Math. 11, 431–441 (1963).
Zener, C. Elasticity and Anelasticity of Metals. (University of Chicago, Chicago, 1948).
Acknowledgements
This work was supported by the National Natural Science Foundation of China (11834008, 11874217, and 21871143).
Author information
Authors and Affiliations
Contributions
T.Z. performed the theoretical calculations, photoacoustic measurements, and data analysis. X.Y.L. provided specimens. C.T. conceived the project and designed the research. X.X. and X.J.L. discussed the results.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zhang, T., Liu, Xy., Tao, C. et al. Noncontact evaluation of full elastic constants of perovskite MAPbBr3 via Photoacoustic eigen-spectrum analysis in one test. Sci Rep 10, 9994 (2020). https://doi.org/10.1038/s41598-020-66938-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-66938-2
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.