Abstract
Existing techniques for patterning metallic structures on elastomers are limited in terms of resolution, yield and scalability. The primary constraint is the incompatibility of their physical properties with conventional cleanroom techniques. We demonstrate a reliable fabrication strategy to transfer high resolution metallic structures of <500 nm in dimension on elastomers. The proposed method consists of producing a metallic pattern using conventional lithographic techniques on silicon coated with a thin sacrificial aluminium layer. Subsequent wet etching of the sacrificial layer releases the elastomer with the embedded metallic pattern. Using this method, a nano-resistor with minimum feature size of 400 nm is fabricated on polydimethylsiloxane (PDMS) and applied in gas sensing. Adsorption of solvents in the PDMS causes swelling and increases the device resistance, which therefore enables the detection of volatile organic compounds (VOCs). Sensitivity to chloroform and toluene vapor with a rapid response (~30 s) and recovery (~200 s) is demonstrated using this PDMS nano-resistor at room temperature.
Similar content being viewed by others
Introduction
Electronics made on elastomers represent an emerging class of technology that have found applications in various areas including electronic skin1, flexible solar cell2, stretchable display3, bendable touchpad4, implantable neuroelectrode5, neural prosthesis6, electronic eye camera7, and wearable sensor for continuous monitoring8,9,10. Polydimethylsiloxane (PDMS) plays a crucial role in such devices, serving as an encapsulation11, dielectric12 or substrate13 due to its desirable properties such as low electrical conductivity, easy preparation, biocompatibility, deformability and chemical inertness in the body environment14. However, one undesirable characteristic of PDMS is its affinity towards organic compounds as the silicone could swell massively upon contact with the liquids15,16. As a result, complications arise during device fabrication, as organic solvents/vapors are often used.
Nevertheless, the swelling properties of PDMS could prove useful as an active layer for gas sensing applications. Martinez Hurtado et al. demonstrated that a holographic sensor for volatile organic compounds (VOC) could be made with PDMS by laser ablation of the diffused silver salts in the polymeric network17. The response was recorded as a shift in wavelength in the elastomer as the position of the fringes altered. Similarly, Park et al. showed an optical sensor based on PDMS coated fiber Bragg grating18. However, these optical sensing technologies would require a separate light source to work. More recently, Rumens et al. reported a passive radio frequency identification device (RFID) which utilized PDMS as a mechanical actuator but this technique has a slow response time and low sensitivity19. Gravimetric sensing techniques using bulk (either solidly mounted resonators or quartz crystal microbalances) or surface acoustic waves with PDMS as the sorbent material for VOCs to produce small mass changes that are ultimately detected as frequency shifts have also been demonstrated20,21,22. However, using an additional coating layer on mass-sensitive devices causes acoustic wave leakage, which damps the resonance and hence reduce the device sensitivities22. In this article, we introduce a simple concept for the detection of VOC by the direct fabrication of a thin film nano-resistor onto PDMS, which acts as both the sorbent and the substrate material simultaneously.
Direct fabrication of thin metallic films with high resolution features on PDMS is challenging23. The large coefficient of thermal expansion (CTE) (~0.31% per K) of PDMS compared to conventional photoresists causes significant expansion mismatch that results in the crack formation during lithography24,25,26,27. The alternate solution of using wet etching of the metal deposited on PDMS leads to undercutting due to the isotropic etching reaction, which restricts both the resolution and density of the electrodes28,29,30. Metal deposition via conventional shadow masks has also been reported but is limited to large features (>100 µm) and simple designs31,32. More recently, Zhang et al. have proposed the use of ultrathin parylene films (2 μm thick) as shadow masks to pattern microelectrodes but still achieved only 5 μm in channel length (spacing between electrodes)33. Carrier substrates have also been used to transfer patterns from silicon (Si) to elastomeric substrates but such thin polymer films are generally difficult to handle10,34. Similarly, pattern transfer through dry peeling damages devices in the nanoscale due to the stress induced by the process to the devices35. Therefore a technique to achieve low-stress and high-resolution electrodes on elastomers is a significant advancement.
In this work we demonstrate a fabrication strategy that overcomes the current limitations of reported techniques. We employ a thin aluminium (Al) sacrificial layer as a temporary substrate that is compatible with conventional lithographic techniques. The key properties of this Al layer are: (i) the ease of removal with minimal stress, and (ii) template stripping can be applied to create a low roughness surface for high resolution patterning. Hence, a conducting device in the nanometer dimension range can be transferred onto a range of spin casted polymers such as PDMS. Based on this fabrication process, we demonstrate a standalone sensing mechanism for VOCs based on direct fabrication of high resolution nano-resistor on PDMS. This proof of concept study explores a miniaturized sensor, with resolution in the nanometer range, which responds to the swelling of PDMS. We also propose a “mesh” design for a wide coverage both in the vertical and in the horizontal directions, and hence higher sensitivity in response to the swelling in the elastomeric film. To validate the proof-of-concept device for VOC detection, we tested the nano-sensor device against VOCs with health implications such as chloroform and toluene.
Results and Discussions
Figure 1 illustrates the key steps to fabricate high resolution gold (Au) patterned conductive structures onto the PDMS. We first sputtered ~150 nm of Al onto a blank Si substrate as a rigid sacrificial layer. We subsequently define the patterns used for gas detection by electron beam lithography (EBL) and deposited 50 nm of Au and 4 nm of titanium (Ti) via e-beam evaporation. Ti is necessary for adhesion of the Au on the Al surface and can be removed after the transfer. After lift-off, we immersed the samples in 3-mercaptopropyl trimethoxysilane (MPTMS) solution to create a stable bond between Au and PDMS as reported in previous studies36,37. We then spin-casted degassed PDMS on the patterned Al and cured the samples at room temperature. Finally, we etched the sacrificial layer in dilute hydrochloric (HCl) solution to release the Au/Ti embedded PDMS with minimal induced stress.
Figure 2(a) and (b) show the dark field optical image and scanning electron microscope (SEM) image of the Au mesh patterned on PDMS respectively. These structures remained highly conductive on PDMS, suggesting that there was minimal or no fracture of the metallic layer38. As compared to previous studies, wrinkling or buckling of thin metal films on PDMS were not observed (see Supporting Information Figure S1) in our method, as the elastomer was not subjected to heat treatment39,40,41. This is an important feature for the resistive based sensor due to the limited stretchability. Furthermore, heating of PDMS would exert excessive thermal stress on the patterned nanostructures, which would lead to the loss of connection within the mesh. Figure 2(c) shows a magnified view of the device, and the width of the mesh was measured to be ~400 nm. Granular structures (average grain size of 111 nm in diameter) of the Au films were observed as the metal was grown directly on the sputtered Al. The physical vapor deposition of metals such as Al is governed by the nucleation, island formation rates, and energy density of the metallic atoms arriving on the substrate42. As a result, Al sputtered onto a flat surface such as Si would have a significant root mean square (rms) surface roughness (~9.6 nm) as observed in Fig. 2(d), and this rms roughness can be increased with the deposition temperature43. Depositing this Al sacrificial layer at higher temperatures could also increase the surface roughness that the Au layer inherits, and would potentially improve the stretchability of devices fabricated on elastomers. However, this will be achieved at the expense of a loss in resolution when fabricating dense nanoscale features on uneven surfaces, as this is limited by electron beam/UV light scattering.
We then characterized the electrical response (current, I versus voltage, V) of the device under controlled environment using the setup shown schematically in Fig. 3(a). For the tests we connected our device onto a printed circuit board (PCB) via both silver paste and thin copper leads. We then loaded the device in a custom-made gas test chamber, which was sealed with O-rings while the PCB was connected to Keithley Source Measurement Units (SMUs) located outside the measurement chamber as shown schematically in Fig. 3(a). Using this set-up, we compared the I-V characteristics of the mesh structure transferred on PDMS to that of similar devices fabricated directly on Si. We observed consistent electrical responses between the devices made on PDMS and their Si counterparts as shown in Fig. 3(b) where values of electrical resistance, R (V/I), of 146 Ω and 150 Ω were measured on PDMS and on Si respectively. Using calibrated mass flow controllers (MFCs) we performed gas sensing measurements of chloroform, toluene, isopropyl alcohol (IPA) and water vapor at various concentrations, achieved via dry air dilution.
In our experiments, we fixed a continuous total flowrate of 500 sccm into the system. We defined 500 sccm flow of dry air as a baseline for the sensor. We directed the entire airflow to the bubbler, as shown in Fig. 3(a), to displace the saturated vapor of chloroform, toluene, IPA and water with respective concentrations of 4.40 × 105 ppm, 3.80 × 104 ppm, 6.36 × 104 ppm and 2.43 × 104 ppm for 30 seconds. The device was then allowed to recover in the flow of dry air for 10 minutes before the next pulse. We measured consistent electrical responses across the measurements of the same compound but different behavior towards different vapors, due to the distinct interactions of these molecules with the PDMS active layer.
When subjected to chloroform vapor (4.40 × 105 ppm), the resistance of the devices fabricated on PDMS increased by ~43 Ω, whereas no change was detected on the Si nano-resistor, as illustrated in Fig. 4(a). As chloroform is a halogenated organic solvent with a high solubility parameter of 9.2 cal½ cm−3/2 towards PDMS, it can cause swelling in the PDMS and impart mechanical stress onto the embedded metal nanostructures44. Such swelling induced stress would not be generated onto the nano-sensors deposited on Si substrate, resulting in unchanged resistance value. We also observed the full recovery of the devices as the value of R dropped back to the baseline within 3 minutes after dry air was flushed through the system. Likewise, we found that PDMS swells in the presence of saturated toluene vapor (3.80 × 104 ppm), recording a ΔR of ~37 Ω, as shown in Fig. 4(b). However, not only were the devices unable to make a full recovery within 10 minutes, but the baseline R also increased after each toluene pulse, as shown in the same Fig. 4(b). This could be attributed by the high affinity of toluene towards the silcones and the higher boiling point (b.p.) of toluene (~110 °C) compared to chloroform (b.p. 61.5 °C), which renders the removal and evaporation of the toluene molecules more difficult once they diffuse through the PDMS. To achieve recovery of the sensor resistance, the device can be heated after toluene exposure to facilitate the out-diffusion of the toluene molecules from the PDMS. In the case of IPA (Fig. 4(c)), we did not see any change within the 30 seconds pulse intervals. This could be due to either the insignificant stretching of the resistor or the slower swelling response of the PDMS as IPA is more polar in nature, leading to a stronger repulsion of IPA molecules by the hydrophobic PDMS surface. We observed from Fig. 4(d) that the value of R of the devices decreased slightly with water vapor, where a ΔR of ~−1.5 Ω was measured. This can be explained by the fact that the nano-resistors embedded in the polymeric network were already subjected to stress due to prior swelling responses and this could have created discontinuities in the film. As water vapor may get adsorbed onto the Au or Ti (with a strong gettering effect) grains, the discontinuities will be filled and hence the conductivity of this VOC sensor could be improved45. At each injection point of water vapor in the chamber, the water molecules shorted the mesh on the PDMS resulting in a more conductive pathway between the contacts. In contrast, this was not observed with the more rigid Si reference device, which instead demonstrated a gradual drift in R by +2 Ω over the measurement time. Nevertheless, these findings suggest that ambient humidity does not have a strong impact on the sensing response. Our results also showed that PDMS has a preferential selectivity towards compounds of high hydrophobicity and solubility parameter values close to PDMS.
We then characterized the nano-resistors fabricated on PDMS against chloroform, toluene and water vapor at various concentrations as shown in Fig. 5. We diluted the saturated vapor of the corresponding solvent from the bubbler with dry air at varying flow rates (See Supporting Information Tables S1, S2 and S3 for dilution data). Chloroform vapor of 7.5 × 104 ppm was injected into the system until the value of R reached a steady state. The measurements were repeated with lower concentrations of the same vapor at 5000 ppm intervals. We detected down to 1 × 104 ppm of chloroform with an applied voltage of 1 mV. Over the concentration range tested, the nano-resistors exhibited a linear response toward chloroform with a sensitivity of 2.18 × 10−4 Ω/ppm as shown in Fig. 5(a). The VOC sensors shown in this work responded to toluene vapor concentrations as low as 1000 ppm. Additionally, concentrations as low as 200 ppm of toluene vapor were detected when we improved the signal to noise ratio of the nano-resistor by increasing the applied voltage by a further 0.5 mV to 1.5 mV. We observed a linear response to toluene vapor at concentrations up to 10000 ppm followed by a non-linear increase in ΔR as shown in Fig. 5(b). Despite a prior study reporting that PDMS swells more in chloroform than toluene liquid, we observed the converse when performing the measurements in these two organic vapors46. The more sensitive behavior of the nano-resistor on PDMS towards toluene vapor could be correlated to the closer resemblance of Hildebrand value: δ = c1/2 = −(U/V)1/2, where c (cal/cm3) represents the cohesive energy value, U represents the molar internal energy (cal/mol) and V represents the molar volume (cm3/mol)15,47. Another contributing mechanism could be the non-polarity of toluene with electronegativity value of 3.86 eV compared to of 5.51 eV for chloroform. This lower electronegativity of toluene may result in strong affinity of toluene vapor, which displayed a stronger interaction with PDMS in our experiments46. Water vapor only affects the device’s electrical responses above 8000 ppm threshold value. However, no clear trend was observed over the concentration range we investigated.
To ascertain that this VOC sensor can be used for real-time monitoring with negligible effects from environmental changes, we calibrated the effects of temperature on ΔR. Our experiments showed that the value of R of the nano-resistors increased by only ~2 Ω for every 10 °C increase in the surrounding temperature (See Supporting Information Figure S2). This change in resistance is negligible compared to the ΔR values observed for chloroform and toluene. If required, the effects of temperature drift could be taken into account by pairing the gas sensor device with a temperature sensor fabricated on silicon substrates. Further optimization is still required to improve the overall performance of the device as a gas sensor. The sensitivity of the gas sensor could be enhanced by the design of the resistor, material used for the resistor and possibly the shape of the polymeric layer. The selectivity of the gas sensor could be achieved by functionalization of the PDMS layer48. We also propose to apply this setup (nano-resistors fabricated directly onto the active layer) to other sensing materials for the discrimination of gas species present at trace levels. It is noted that, as for all resistive-type gas sensors, known techniques to provide cross-sensitivity analysis against interferent species in a gas mixture could be applied to the proposed approach, such as those based on multisensor arrays and pattern recognition (often referred to as electronic nose)49,50. From these experiments however, we have demonstrated a nanofabrication strategy to pattern conductive metallic structures of dimensions as small as 400 nm. Our method could be modified for applications that require a flat interface or standalone structures below 50 nm on elastomers such as plasmonic waveguides on polymers, which could be also accomplished by self-assembly of metal nanoparticles51,52,53. Other applications for high resolution features on polymers include tunable grating structures, and stamps with embedded metal for nanoimprinting. To achieve higher resolution features, we reduced the surface roughness of the sacrificial layer by sputtering the Al layer directly on freshly cleaved mica instead of Si substrates for template stripping (See Supporting Information Figure S3). Consequently, the rms roughness of the sacrificial Al layer reduced by ~80 folds to as low as ~0.1 nm. To confirm the viability of our method for high resolution patterning on PDMS, we subsequently patterned Au/Ti features of ~25 nm in width on the flatter Al surface and successfully transferred them onto PDMS (See Supporting Information Figures S4 and S5 for AFM images).
Conclusion
In this work, we have shown that conductive and high resolution metallic structures can be fabricated onto elastomeric materials such as PDMS. Our approach in adopting a metallic sacrificial layer in transferring patterns defined by lithographic techniques, which overcomes the shortcomings of previously reported fabrication strategies. As the samples were subjected to minimal stress, devices made by this method remained conductive at the end of the process. We have applied the proposed method to demonstrate a nano-resistor with mesh design with features as small as ~400 nm embedded in PDMS for VOCs detection as a proof of concept. Using PDMS as both a substrate and an active layer simultaneously, our sensors showed preferential selectivity towards toluene and chloroform but did not swell in response to IPA and water within the exposure time. This study could also contribute to the stretchable electronics community in the design of high performance devices through miniaturization of existing works on elastomers, potentially paving the way for new applications in the future. We anticipate this proof of concept sensing mechanism could be further developed into technologies for continuous monitoring of a range of both vapors and liquids, and into fabrication of devices for point of care (PoC) diagnostics.
Methods
Sacrificial layer deposition and patterning
Al sacrificial layers (~150 nm thick) were deposited on Si wafers in a DC magnetron sputtering system (Metallifier sputter coater, Precision Atomics, Cambridge, UK) using a 100 mm diameter and 3 mm thick Al target (purity 99.95%). The deposition conditions for Al were 3.5 × 10−3 mbar sputtering pressure, 30 sccm of 99.999% purity Ar and 100 W power, giving a deposition rate of ~6 nm/min. The Si wafers were then diced into 1 cm length square chips, and PMMA (A4 950 K) was spin-coated on the chips at 5500 rpm and baked at 200 °C for 2 mins on a hotplate. The design of the sensor consisted of 2 pads of 1 × 1 mm and separated by 1 mm. The pads were connected by a mesh with a period 16 µm repeated by 62 times laterally and 20 times perpendicularly. The mesh pattern was produced using EBL (Nanobeam nB5 80 kV, Cambridge, UK) with a dose of 6 C/m2. After exposure the PMMA was developed in a 1:3 mixture of MIBK:IPA for 20 s, rinsed for 15 s in IPA and then dried with nitrogen. Au (50 nm) and Ti (4 nm) were subsequently evaporated in an e-beam evaporator (Model PVD75, Kurt J Lesker, Jefferson Hills, PA, USA) with the respective deposition rate of 0.04 nm/s and 0.03 nm/s. Excess Au/Ti were lifted-off in acetone with sonication, followed by cleaning with acetone, IPA and nitrogen drying. 95% (3-mercaptopropyl) trimethoxysilane purchased from Sigma-Aldrich (Dorset, UK) was used to prepare a solution of 60 mM of the silane in absolute ethanol. The chips were then immersed in the prepared solution for 2 hours and subsequently rinsed with clean absolute ethanol.
Elastomer preparation and pattern transfer
PDMS (Sylgard 184) was purchased from Dow Corning (Seneffe, Belgium); the base and curing agent were mixed in the mass ratio 10:1 and degassed in a vacuum desiccator for 2 hours. The resulting polymer was then spin-coated at 1000 rpm for 40 s on the Au/Ti patterned chips to obtain a PDMS thickness of approximately 170 µm. PDMS curing was carried out in ambient cleanroom conditions for 72 hours. Standard HCl (37% by mass) was purchased from Sigma-Aldrich (Dorset, UK) and diluted with de-ionized (DI) water (volume ratio 1:6), which was then used to etch the sacrificial Al layer for 5 hours. The released PDMS with the embedded Au patterns was then washed in DI water and dried with nitrogen. The resulting PDMS was then briefly treated with oxygen plasma for 10 seconds.
Device characterization and sensor performance
The devices fabricated on PDMS were sputter coated with a thin Au/Pd (palladium) layer for SEM imaging. SEM images of the devices were acquired using a LEO GEMINI 1530VP field-emission system (Zeiss, Oberkochen, Germany) with an acceleration voltage of 2 kV. Tapping mode AFM (Agilent 5500 scanning probe microscope, Palo Alto, CA, USA) was used to characterize the roughness inherited from the sacrificial Al surface. Solvents including chloroform, toluene and IPA were purchased from Fisher Scientific (Loughborough, UK) for gas sensing measurements.
Data Availability
Data generated or analyzed during this study are included in this published article (and its Supplementary Information files).
Change history
11 September 2018
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.
References
Hammock, M. L., Chortos, A., Tee, B. C.-K., Tok, J. B.-H. & Bao, Z. 25th anniversary article: The evolution of electronic skin (E-Skin): A brief history, design considerations, and recent progress. Adv. Mater. 25, 5997–6038 (2013).
Kaltenbrunner, M. et al. Ultrathin and lightweight organic solar cells with high flexibility. Nat. Commun. 3, 770 (2012).
Sekitani, T. et al. Stretchable active-matrix organic light-emitting diode display using printable elastic conductors. Nat. Mater. 8, 494–499 (2009).
Sarwar, M. S. et al. Bend, stretch, and touch: Locating a finger on an actively deformed transparent sensor array. Sci. Adv. 3 (2017).
McClain, M. A. et al. Highly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS. Biomed. Microdevices 13, 361–373 (2011).
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W. & Lacour, S. P. Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array. Lab Chip 12, 2540–51 (2012).
Ko, H. C. et al. A hemispherical electronic eye camera based on compressible silicon optoelectronics. Nature 454, 748–753 (2008).
Gong, S. et al. A wearable and highly sensitive pressure sensor with ultrathin gold nanowires. Nat. Commun. 5, 838–843 (2014).
Wu, J. et al. Inkjet-printed microelectrodes on PDMS as biosensors for functionalized microfluidic systems. Lab Chip 15, 690–695 (2015).
Lee, H. et al. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module. Sci. Adv. 3 (2017).
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T. & Lucisano, J. Y. Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals. Sci. Transl. Med. 2 (2010).
Mannsfeld, S. C. B. et al. Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nat. Mater. 9, 859–864 (2010).
Ko, E.-H., Kim, H.-J., Lee, S.-M., Kim, T.-W. & Kim, H.-K. Stretchable Ag electrodes with mechanically tunable optical transmittance on wavy-patterned PDMS substrates. Sci. Rep. 7, 46739 (2017).
Mcdonald, J. C. & George M. Whitesides. Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices. Acc. Chem. Res. 35, 491–499 (2002).
Lee, J. N., Park, C. & Whitesides, G. M. Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices. Anal. Chem. 75, 6544–6554 (2003).
Honda, T., Miyazaki, M., Nakamura, H. & Maeda, H. Controllable polymerization of N-carboxy anhydrides in a microreaction system. Lab on a chip 5, 812–818 (2005).
Martínez-Hurtado, J. L., Davidson, C. A. B. & Lowe, C. R. Monitoring organic volatiles and flammable gases with a holographic sensor. In SPIE Defense, Security, and Sensing, https://doi.org/10.1117/12.887295 (2011).
Park, C. et al. Optical detection of volatile organic compounds using selective tensile effects of a polymer-coated fiber Bragg grating. Opt. Express 18, 24753 (2010).
Rumens, C. V., Ziai, M. A., Belsey, K. E., Batchelor, J. C. & Holder, S. J. Materials Chemistry C Materials for optical, magnetic and electronic devices Swelling of PDMS networks in solvent vapours; applications for passive RFID wireless sensors Swelling of PDMS networks in solvent vapours; applications for passive RFID wireless sensors. J. Mater. Chem. C 3, 10091–10098 (2015).
Johnston, M. L., Edrees, H., Kymissis, I. & Shepard, K. L. Integrated VOC vapor sensing on FBAR-CMOS array. in 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS) 846–849, https://doi.org/10.1109/MEMSYS.2012.6170318 (IEEE, 2012).
Ha, B. H., Park, J., Destgeer, G., Jung, J. H. & Sung, H. J. Generation of Dynamic Free-Form Temperature Gradients in a Disposable Microchip. Anal. Chem. 87, 11568–11574 (2015).
Leung, W. W. F. et al. Measurement of Solvent Vapor Absorption by Polydimethylsiloxane Using Quartz Crystal Microbalance. in 2008 Second International Conference on Integration and Commercialization of Micro and Nanosystems 163–166, https://doi.org/10.1115/MicroNano2008-70163 (ASME, 2008).
Tan, E., Jing, Q., Smith, M., Kar-Narayan, S. & Occhipinti, L. Needs and Enabling Technologies for Stretchable Electronics Commercialization. MRS Adv. 1–9, https://doi.org/10.1557/adv.2017.2 (2017).
Kunnavakkam, F. M. et al. Low-cost, low-loss microlens arrays fabricated by soft-lithography replication process. Cit. Appl. Phys. Lett 82 (2003).
Patel, J. N., Kaminska, B., Gray, B. L. & Gates, B. D. A sacrificial SU-8 mask for direct metallization on PDMS. J. Micromechanics Microengineering 19, 115014 (2009).
Guo, L. & Deweerth, S. P. An effective lift-off method for patterning high-density gold interconnects on an elastomeric substrate. Small 6, 2847–2852 (2010).
Jeong, D.-W., Jang, N.-S., Kim, K.-H. & Kim, J.-M. A stretchable sensor platform based on simple and scalable lift-off micropatterning of metal nanowire network. RSC Adv. 6, 74418–74425 (2016).
Adrega, T. & Lacour, S. P. Stretchable gold conductors embedded in PDMS and patterned by photolithography: fabrication and electromechanical characterization. J. Micromechanics Microengineering 20, 55025 (2010).
Meacham, K. W., Giuly, R. J., Guo, L., Hochman, S. & DeWeerth, S. P. A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord. Biomed. Microdevices 10, 259–269 (2008).
Franssila, S. Introduction to Microfabrication Introduction to Microfabrication Second Edition. (John Wiley & Sons, 2010).
Viventi, J. et al. Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo. Nat. Neurosci. 14, 1599–605 (2011).
Song, Y. M. et al. Digital cameras with designs inspired by the arthropod eye. Nature 497, 95–99 (2013).
Zhang, S. et al. Patterning of Stretchable Organic Electrochemical Transistors. Chem. Mater. 29, 3126–3132 (2017).
Deng, W. et al. A High-yield Two-step Transfer Printing Method for Large-scale Fabrication of Organic Single-crystal Devices on Arbitrary Substrates. Sci. Rep. 4, 4772–4776 (2014).
Byun, I., Coleman, A. W. & Kim, B. SAM meets MEMS: reliable fabrication of stable Au-patterns embedded in PDMS using dry peel-off process. Microsyst. Technol. 20, 1783–1789 (2014).
Lee, K. J., Fosser, K. A. & Nuzzo, R. G. Fabrication of Stable Metallic Patterns Embedded in Poly(dimethylsiloxane) and Model Applications in Non-Planar Electronic and Lab-on-a-Chip Device Patterning. Adv. Funct. Mater. 15, 557–566 (2005).
Byun, I., Coleman, A. W. & Kim, B. Transfer of thin Au films to polydimethylsiloxane (PDMS) with reliable bonding using (3-mercaptopropyl)trimethoxysilane (MPTMS) as a molecular adhesive. J. Micromech. Microeng 23, 85016–10 (2013).
Kim, J. et al. Highly stretchable wrinkled gold thin film wires. Appl. Phys. Lett. 108 (2016).
Meng, Y., Li, Z. B., Chen, X. & Chen, J. P. Reducing wrinkles and cracks of metal films on PDMS substrate by hexane extraction and oxygen plasma etching. Microelectron. Eng. 130, 8–12 (2014).
Bowden, N., Brittain, S., Evans, A. G., Hutchinson, J. W. & Whitesides, G. M. Spontaneous formation of ordered structures in thin. Nature 393, 146–149 (1998).
Graudejus, O., Gorrn, P. & Wagner, S. Controlling the morphology of gold films on poly(dimethylsiloxane. ACS Appl. Mater. Interfaces 2, 1927–1933 (2010).
Gilmer, G. H., Huang, H., De La Rubia, T. D., Torre, J. D. & Baumann, F. Lattice Monte Carlo models of thin film deposition. Thin Solid Films 365, 189–200 (2000).
Rughoobur, G. et al. Gravimetric sensors operating at 1. 1 GHz based on inclined c - axis ZnO grown on textured Al electrodes. Sci. Rep. 7, 1367 (2017).
Vinothkumar, T. S., Deivanayagam, K., Ganesh, A. & Kumar, D. Influence of different organic solvents on degree of swelling of poly (dimethyl siloxane)-based sealer. J. Conserv. Dent. 14, 156–9 (2011).
Lazarov, D. L. & Manev, S. G. Conductivity Changes of Thin Discontinuous Metal Films under Gas and VapourAdsorption. Zeitschrift für Phys. Chemie 258O, 449–463 (1977).
Choi, J., Zhang, H., Du, H. & Choi, J. H. Understanding Solvent Effects on the Properties of Two-Dimensional Transition Metal Dichalcogenides. ACS Appl. Mater. Interfaces 8, 8864–8869 (2016).
Physical Properties of Polymers Handbook., doi:10.1007/978-0-387-69002-5 (Springer New York, 2007).
Adhikari, B. & Majumdar, S. Polymers in sensor applications. Prog. Polym. Sci. 29, 699–766 (2004).
Al-Naimi, F. et al. Investigation of polymer deposition techniques on a Solidly Mounted Resonator arrays for vapour sensing. In Proceedings of IEEE Sensors 2014–Decem (2014).
Pearce, T. C. (Tim C. Handbook of machine olfaction: electronic nose technology. (Wiley-VCH, 2003).
Sun, Y., Jiang, L., Zhong, L., Jiang, Y. & Chen, X. Towards active plasmonic response devices. Nano Res. 8, 406–417 (2015).
Jiang, L. et al. Synergistic Modulation of Surface Interaction to Assemble Metal Nanoparticles into Two-Dimensional Arrays with Tunable Plasmonic Properties. Small 10, 609–616 (2014).
Jiang, L. et al. Synthesis of Fivefold Stellate Polyhedral Gold Nanoparticles with {110}-Facets via a Seed-Mediated Growth Method. Small 9, 705–710 (2013).
Acknowledgements
The authors wish to acknowledge Zongyin Yang from Cambridge Graphene Centre, University of Cambridge for the useful discussions. The authors also wish to acknowledge Mark Welland from the Nanoscience Centre, University of Cambridge for supporting the resources required for the project. E.K.W.T. received funding from Trinity Hall, University of Cambridge, EPSRC CDT in Nanoscience and Nanotechnology (Grant no. EP/L015978/1), EPSRC Centre for Innovative Manufacturing in Large Area Electronics (Grant no. EP/K03099X/1). G.R. received funding from Cambridge Commonwealth, European and International Trust. L.G.O acknowledged funding support from MP-SENS Innovate UK (Grant No. 73047-501268) and EC Project H2020 1D-NEON (Grant Agreement No. 685758).
Author information
Authors and Affiliations
Contributions
E.K.W.T. wrote the manuscript, designed the experiments, fabricated the devices, characterized the samples, and analyzed the data. G.R. wrote the manuscript, supported the fabrication of the devices, analyzed the data and prepared the schematics. J.R.-L. characterized the devices, supported the fabrication of the devices and analyzed the data. N.T. built the gas sensing setup. Z.X. characterized the devices. C.A.B.D. contributed to idea of gas sensing. C.R.L. contributed to idea of gas sensing and advised the project. L.G.O. supplied the resources for the experiments, contributed to the idea and advised the project. All authors reviewed and discussed the manuscript.
Corresponding authors
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Tan, E.K.W., Rughoobur, G., Rubio-Lara, J. et al. Nanofabrication of Conductive Metallic Structures on Elastomeric Materials. Sci Rep 8, 6607 (2018). https://doi.org/10.1038/s41598-018-24901-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-24901-2
Keywords
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.