Abstract
Arterial oxygen partial pressure can increase during inspiration and decrease during expiration in the presence of a variable shunt fraction, such as with cyclical atelectasis, but it is generally presumed to remain constant within a respiratory cycle in the healthy lung. We measured arterial oxygen partial pressure continuously with a fast intra-vascular sensor in the carotid artery of anaesthetized, mechanically ventilated pigs, without lung injury. Here we demonstrate that arterial oxygen partial pressure shows respiratory oscillations in the uninjured pig lung, in the absence of cyclical atelectasis (as determined with dynamic computed tomography), with oscillation amplitudes that exceeded 50 mmHg, depending on the conditions of mechanical ventilation. These arterial oxygen partial pressure respiratory oscillations can be modelled from a single alveolar compartment and a constant oxygen uptake, without the requirement for an increased shunt fraction during expiration. Our results are likely to contribute to the interpretation of arterial oxygen respiratory oscillations observed during mechanical ventilation in the acute respiratory distress syndrome.
Introduction
In the healthy lung, arterial partial pressure of oxygen (PaO2) is thought to remain almost constant within the respiratory cycle during spontaneous breathing, via a physiological PO2 gradient between the alveoli and the pulmonary circulation1. Respiratory PaO2 oscillations smaller than 16 mmHg have been detected with slow response time sensors2 in animals with uninjured lungs when abnormally large tidal volumes (VT) greater than 20 ml kg−1 or even 30 ml kg−1 were delivered during mechanical ventilation3, 4.
In the injured lung, especially in animal models of the acute respiratory distress syndrome (ARDS), large PaO2 oscillations have been observed by means of fast-response oxygen sensing technology5,6,7,8,9,10,11,12. Here, PaO2 oscillations have been explained by variable within-breath shunt due to the repetitive opening and collapse of lung regions (cyclical atelectasis), causing PaO2 to increase during inspiration and decrease during expiration. This phenomenon may be used to personalize mechanical ventilation based on real-time, continuous PaO2 monitoring, where the appearance of an oscillating PaO2 signal may be a diagnostic biomarker for cyclical atelectasis.
A significant limitation of the above mentioned studies is that the PaO2 oscillations observed in animal models of ARDS mostly appeared in association with a high average VT of 20 ml kg−1 7, 13, 30 ml kg−1 6, 14, or greater10. These large VT were delivered in experiments without application of positive end-expiratory pressure (PEEP), and imposing elevated peak end-expiratory pressures in order to provoke cyclical atelectasis in the injured lung. Even with these large VT, PaO2 oscillations only between 3 and 22 mmHg were observed in the uninjured lung, at a RR lower than 10 breaths per minute, and mean PaO2 above 450 mmHg6, 15.
No study employing fast oxygen-sensing technology has explored the responses of the uninjured lung to mechanical ventilation at physiological PaO2 levels. Experimental evidence for this response to mechanical ventilation could also be useful to understand response of the lung to mechanical ventilation in the presence of injury.
We developed a fibre optic oxygen sensor16, optimized its response time and linearity17,18,19,20, tested it in vitro 21, showed it to be resistant to clotting, and demonstrated it to be capable of detecting rapid PaO2 changes in an animal model of ARDS18, 34. With this new technique to study gas exchange dynamically, we explore here PaO2 responses to mechanical ventilation in a porcine model.
We hypothesised that in apnoea or expiration PaO2 declines at a rate that is inversely proportional to lung volume, as had been modelled22, 23, and that this decline would be readily measurable in the uninjured pig lung during 20 s end-expiratory and end-inspiratory breath holds. We also hypothesised that, during tidal breathing, PaO2 oscillates dynamically in phase with lung volume in the uninjured lung, in the absence of cyclical atelectasis. This hypothesis led us to also explore the possibility that different ventilation strategies (pressure and volume control) and inspired-to-expired ratios could affect the mean PaO2 value, while airway pressures (end-expiratory and end-inspiratory), respiratory rate, or fraction of inspired oxygen (FIO2) were kept unvaried.
Results
PaO2 oscillates during tidal breathing with mechanical ventilation
Figure 1 illustrates the tidal nature of PaO2 as observed in an anesthetised pig with uninjured lungs during volume (VC) and pressure control (PC) mechanical ventilation. PaO2 oscillations with an amplitude of about 10 mmHg and the same frequency as breathing were observed at a RR of 12 breaths per minute, inspired-to-expired ratio (I:E) of 1:1, tidal volume (VT) of about 10 ml kg−1, and at mean PaO2 near 130 mmHg. The peak airway pressure was maintained below 13.6 cmH2O. The airway pressure remained lower than the mean pulmonary artery pressure throughout the experiment.
PaO2 oscillations in the uninjured, ventilated lung. Representative continuous measurements of PaO2 (top, black), pulmonary artery pressure (middle, light grey) and airway pressure (bottom, dark grey) are presented as a function of time. Ventilation was managed in volume control (left, VC) and pressure control (right, PC) mode. Inspired-to-expired ratio was 1:1, and respiratory rate was 12 breaths per minute.
The rate of PaO2 decline during breath holding depends on lung volume and metabolic rate, and is not associated with atelectasis in the uninjured lung
Figure 2 shows the rate of PaO2 decline over time during breath hold manoeuvres at end-expiratory volume (493 ml; left), end-inspiratory volume (783 ml; centre), and at the end of a large inspiration (1,073 ml; right). The figure illustrates the slower rate of decline observed at the larger lung volume, where also a transient increase in PaO2 was observed immediately following the large inspiration. There was good agreement between measurements of VT recorded via the respiratory monitor (Datex Ultima) and estimates of the lung volume increases consequent upon inflation made by CT image analysis: the mean volume difference (i.e. bias) was −22 ml, with limits of agreement between −67 (95% CI −80 to −54) and 22 (95% CI 9 to 35). The SD of the differences was 23 ml (SE ± 3.7 ml) (Figure S1). Representative slice CT images recorded as soon as the breath hold manoeuvre began, and just before tidal breathing was restored are shown in Figure S2 for reference. Similarly, Figure S3 shows three-dimensional reconstructions of the lung obtained from CT images, highlighting regions associated with different Hounsfield Units ranges corresponding to well- or poorly-ventilated lung, and atelectasis.
PaO2 changes during breath holding manoeuvres at three lung volumes. Representative continuous measurements of PaO2 (top, black), pulmonary artery pressure (middle, light grey), and airway pressure (bottom, dark grey) are presented as a function of time. Lung volumes measured for each breath hold are reported for Ve (end-expiratory breath hold with PEEP set at 3.7 mmHg [5 cmH2O], left), VT10 (end-inspiratory breath hold with VT of 10 ml kg−1, center), and VT20 (breath hold at the end of a large inspiration with VT of 20 ml kg−1, right). Ventilation was in volume control mode, inspired-to-expired ratio was 1:1, and respiratory rate was 12 breaths per minute. Associated CT images were captured at the beginning and end of the breath holding periods, and are presented in the supplementary information.
Table 1 shows that the three lung volumes measured with CT during the breath hold manoeuvres were significantly different (p < 0.001), as were the associated rates of PaO2 decline (p < 0.01). The rates of PaO2 decline ranged from 6.9 ± 1.3 mmHg s−1 at end-expiratory lung volume to 3.4 ± 0.6 mmHg s−1 during the large inspiration (VT20). Table 1 also shows whole lung atelectatic mass fraction measured with CT as soon as the breath hold manoeuvre began and just before breathing was restored. There was no significant difference in the whole lung atelectatic mass fraction at the beginning and at the end of the breath hold manoeuvres [C.I. −1.4%–0.6%].
Respiratory timing affects the PaO2 mean value and the amplitude of its oscillations
Figure 3 shows representative PaO2 values over time during volume (A–D) and pressure (E–H) control mechanical ventilation delivered at a RR of 12 breaths per minute, with PEEP set at 5 cmH2O. These two ventilation modes and I:E ratios of (A, E) 1:2, (B, F) 2:1, (C, G) 1:4 and (D, H) 4:1 affected both the mean PaO2 and the oscillation amplitude. Similarly, Fig. 4 shows representative PaO2 values over time for a RR of 6 breaths per minute, where greater changes in mean PaO2 levels and larger oscillations were observed.
Effects of volume and pressure control ventilation, and inspiration-to-expiration ratio on PaO2 oscillations in the uninjured lung at a respiratory rate of 12 breaths per minute. Representative continuous measurements of PaO2 (top, black), pulmonary artery pressure (middle, light grey) and airway pressure (bottom, dark grey) are presented as a function of time. Ventilation was managed in volume control (VC, upper panels) or pressure control (PC, lower panels) mode. Inspired-to-expired ratio ranged from 1:4 to 4:1; respiratory rate was 12 breaths per minute. The first set of four experiments started with VC, I:E 1:2, and mean PaO2 at 130 mmHg (A), followed by a random sequence of PC and inverted ratios (B,E,F) The second set of four experiments started with VC, I:E 1:4, and mean PaO2 at 130 mmHg (C), followed by a random sequence of PC and inverted ratios (D,G,H).
Effects of volume and pressure control ventilation, and inspiration-to-expiration ratio on PaO2 oscillations in the uninjured lung at a respiratory rate of 6 breaths per minute. See Fig. 3 legend for details.
Table 2 shows the mean PaO2 values associated with the eight combinations of mechanical ventilation settings studied at RR of 12 (VT = 10 ml kg−1), and the associated mean airway pressure. In the experiments considering I:E of 1:2 and 2:1, the ventilation mode (pressure or volume control) resulted in significant PaO2 changes [F(1, 5) = 18.8, p = 0.007], as did inverting I:E ratios (i. e. switching the duration of inspiration with that of expiration) [F(1, 5) = 8.4, p = 0.03]; no significant interaction effect was observed [p > 0.05]. In the experiments considering I:E of 1:4 and 4:1, the ventilation mode resulted in significantly greater PaO2 changes [F(1, 5) = 11.6, p = 0.02], as did inverting I:E ratios [F(1, 5) = 16.5, p = 0.01], with a significant interaction [F(1,5) = 11.5, p = 0.02]. The greatest mean PaO2 change was observed when I:E was inverted from 1:4 in volume control mode to 4:1 in pressure control mode, when the mean PaO2 increased by 19 mmHg, from 125 mmHg (±10 mmHg) to 144 mmHg (±8 mmHg). At RR12 the amplitude of the PaO2 oscillations decreased on average from approximately 10 to about 7 mmHg when inverse-ratio ventilation was used. The reduction in amplitude of the PaO2 oscillations was particularly clear at RR6 (VT = 20 ml kg−1), when inverse-ratio ventilation reduced average PaO2 oscillations from 40 to 15 mmHg, observed respectively in pressure control mode (I:E 1:4) and volume control mode (I:E 4:1). Table 3 shows the similar exaggerated changes observed at RR6. At this RR, the greatest mean PaO2 change was observed when I:E was inverted from 1:4 in volume control mode to 4:1 in pressure control mode, when mean PaO2 increased by 24 mmHg, from 137 mmHg (±18 mmHg) to 161 mmHg (±18 mmHg).
Analysis of CT scans provided no evidence for cyclical atelectasis in the uninjured lung
The change in the mass of the slice that was atelectatic was less than 2% [C.I. 1.5–2.0%] during tidal breathing. Figure 5 shows the proportions of the lung slice mass associated with atelectasis, poor and normal aeration over the period of the respiratory cycle, for each ventilatory condition studied. The atelectatic mass was not different between inspiration and expiration in any of the conditions studied. In contrast, the fraction of normally aerated lung mass increased during inspiration, with a corresponding decrease in the fraction of poorly aerated lung mass. The portion of overinflated lung slice never exceeded 0.1% of the total lung mass.
Variation in mass of different density fractions of a single CT slice during tidal ventilation in uninjured animals in different ventilation modes. During inspiration, atelectatic lung (dark grey) decreased marginally with a greater decrease in poorly aerated mass (light grey) and a reciprocal increase in normally aerated lung (white). Overdistended lung represented less than 0.1% of the mass of the slice and was excluded from the figure. Error bars represent SD at each time point. Panel subtitles indicate ventilation mode and I:E ratio. VC – volume control; PC – pressure control.
A single alveolar compartment model can predict PaO2 changes in the uninjured, ventilated lung
Figure 6 shows the predicted values of \({{\rm{dP}}}_{{\rm{A}}({\rm{t}})}/dt\) according to the proposed model, against the measured values of \({{\rm{dP}}}_{{\rm{A}}({\rm{t}})}/dt\). The predicted values overestimated the measured values by 31%.
Predicted rate of alveolar PO2 decline versus measured rate of PaO2 decline during breath hold manoeuvres. Breath hold manoeuvres were performed at end expiratory lung volume (EELV) (Ve, triangles), at the end of an inspiration corresponding to a VT of 10 ml kg−1 (VT10, empty circles) and at the end of a large inspiration corresponding to a VT of 20 ml kg−1 (VT20, filled circles). Results were obtained in eight animals. EELV was measured in four animals (22.3 ± 3.0 ml kg−1), and having found the functional residual capacity (FRC) in ml kg−1 in these animals, was used to estimate FRC in the remaining four animals. Alveolar volume was estimated as FRC minus dead space, the latter estimated as 3 ml kg−1.
Figure 7 shows results from the simulations of PaO2. These simulations showed changes in mean PaO2, and PaO2 oscillation amplitudes that were similar to those observed in vivo under the various conditions imposed.
Simulations of PaO2 oscillations in the uninjured, ventilated lung from single alveolar model compartment. Simulations of PaO2 (top, black) and airway pressure (bottom, dark grey) are presented as a function of time. Ventilation was simulated in volume control (VC, upper panels A,B,C,D) or pressure control (PC, lower panels E,F,G,H) mode. Simulated inspired-to-expired ratio ranged from 1:4 to 4:1, and respiratory rate was 12 breaths per minute.
Discussion
In this experimental study in mechanically ventilated pigs with uninjured lungs, we showed that PaO2 declined at different rates during breath hold manoeuvres depending on lung volume in vivo, that significant dynamic PaO2 oscillations occur, and that these PaO2 oscillations are determined by alveolar oxygen changes within the respiratory cycle.
During tidal breathing with mechanical ventilation, PaO2 oscillations were observed at respiratory rates of 12 and 6 breaths per minute, at mean PaO2 values between ~120 and ~150 mmHg, at any I:E ratio and ventilation mode considered in this study. These PaO2 oscillations achieved maximum amplitudes greater than 50 mmHg in the absence of cyclical atelectasis as measured by CT image analysis during ventilation in pressure control mode at a RR of 6 breaths per minute, I:E 1:4, VT of 20 ml kg−1, and with 5 cmH2O PEEP. In this sense, any shunt should be of the same magnitude throughout the respiratory cycle, unless blood flow is redistributed within the breath. The observed increase in PaO2 during inspiration suggests that this redistribution of blood flow to non- or poorly ventilated regions did not occur, indicating that it was not a determinant of respiratory PaO2 oscillations.
In agreement with the results obtained during breath holds, the weighted-average lung volume was a strong determinant of mean PaO2 value, as observed by altering I:E ratios and ventilation control mode. In particular, mean PaO2 was higher when inspiration lasted longer than expiration, which is when lung volume is greater across the respiratory cycle. Moreover, the amplitude of the PaO2 oscillations was smaller at greater mean lung volume, suggesting that there was a slower PaO2 decline during the expiratory phase at I:E of 2:1 and 4:1 than when these I:E ratios were inverted. Overall, these respiratory PaO2 oscillations could be predicted from the oscillations in arterial partial pressure of carbon dioxide24.
Respiratory PaO2 oscillations have previously been interpreted primarily as being caused by cyclical atelectasis associated with tidal recruitment and derecruitment during ventilation in animal models of the acute respiratory distress syndrome (ARDS)5, 6, 9, 25. Differences between our work and the published literature include animal species, smaller tidal volumes, greater RR, reduced airway pressures, physiological mean PaO2, and crucially that in our work we studied uninjured lung as opposed to animal models of lung injury. It is possible that the use of much larger tidal volumes (as it appears in the literature) might have resulted in larger PaO2 oscillations in our uninjured lung model; we did not investigate this possibility as tidal volumes greater than those studied in our experiments are neither physiological, nor of clinical interest26. It is intriguing to notice that the PaO2 oscillation amplitude of ~22 mmHg observed at I:E of 4:1, RR 6, VT 20 ml kg−1, mean PaO2 value of ~161 mmHg in our work is similar to that of ~25 mmHg reported in a pig saline lavage model of ARDS in rather similar conditions (I:E 4:1, RR 5, VT 20 ml kg−1,mean PaO2 value of 425 mmHg)9, 27. In this respect, it is possible that the oscillations reported in the literature were caused in part by oxygen mass balance as described in equations 4 and 5 (ventilatory delivery vs pulmonary uptake) rather than cyclical recruitment and derecruitment.
To emphasize the observation that PaO2 rate of decline was associated with lung volume, we performed a series of breath hold experiments at EELV with 5 cmH2O, end-inspiration and at the end of a large inspiration. We showed that PaO2 declined more rapidly at smaller lung volumes than it did at larger lung volumes. This result is in agreement with an original observation performed with slower oxygen saturation sensors during apnea, when the rate of saturation decline was “inversely proportional to the volume of air in the lung during apnea and closely related to the oxygen saturation at the beginning of apnea”28.
This difference in the rate of PaO2 decline could be partly explained by lung recruitment and derecruitment in anaesthetized animals. Lung recruitment could be observed during end-inspiratory breath holds, especially during a breath hold performed after a large inspiration, and derecruitment could be observed during an end-expiratory breath hold. Lung recruitment during an end-inspiratory breath hold could reduce the rate of PaO2 decline, and vice versa during an end-expiratory breath hold. However, in this study, we were unable to detect atelectatic mass changes during breath holds using CT image analysis, which did not provide any evidence for recruitment or derecruitment during end-inspiratory or end-expiratory breath holds respectively. Indeed, this result was partly expected given the short duration of the breath hold manoeuvres, the relatively low pressures used during the inspiratory breath holds, the application of 5 cmH2O PEEP during the end-expiratory breath holds, and the lack of known lung injury or gross regional ventilation-perfusion mismatch.
Ventilation and perfusion changes during a breath hold could determine real time changes in PaO2; in particular, elevated airway pressures applied to the lung during inspiration could cause a prevalence of zone 1 aeration29, 30, where the non-dependent lung regions receive little or no perfusion also due to changes in lung blood volume31. This phenomenon per se would increase the rate of PaO2 decline during an end-inspiratory breath hold, due to a reduced oxygen uptake in the zone 1 regions of the pulmonary circulation. The highest airway pressure applied in our experiments was 24 cmH2O during breath holds at the end of a large inspiration, when the rate of PaO2 decline was slower than during end-inspiratory and end-expiratory breath holds. Importantly, the airway pressure did not exceed the pulmonary artery pressure at any time during breath holds, and overinflated lung mass was never greater than 0.1%, suggesting that zones 1 were not dominant, hence did not affect the rate of PaO2 decline.
Two main limitations of this technology are that it is unable to demonstrate whether a respiratory PaO2 change is caused by alterations in either ventilation, or perfusion, or both, and that it does not provide evidence for their spatial distribution within the lung. In our study, the dynamic CT image analysis partly compensated for this limitation by providing an index of lung aeration and atelectasis. Although this information was anatomically limited to a single slice during tidal breathing, the antero-posterior orientation of the slice could be representative for the effect of the gravitational gradient on pulmonary aeration32.
Our study demonstrates that cyclical atelectasis is not necessary for respiratory PaO2 oscillations to appear during mechanical ventilation. We conclude that the mechanism determining these respiratory PaO2 oscillations is the variation of alveolar oxygen tension within the breath, with oxygen entering the alveoli during each inspiration, and that these cyclic variations in alveolar oxygen tension are transmitted all the way to the systemic arteries. Our results in an anaesthetized, ventilated pig model, in the absence of lung injury, may have implications for the interpretation of the results from conditions of lung disease33, in particular from patients with lung injury, and from animal models of ARDS.
Material and Methods
The study was approved by the Animal Research Ethics Committee at Uppsala University and by the UK Home Office. All the animal experiments conformed to the National Institutes of Health Guidelines for the Use of Laboratory Animals. Relevant sections of the ARRIVE guidelines were followed. A total of 8 domestic pigs were studied (average ± SD: 29 ± 2 kg). Details regarding the anaesthesia, mechanical ventilation, instrumentation and measurements are reported in the supplementary information.
Continuous oxygen sensing
The intravascular, fibre optic oxygen sensor was inserted in a carotid artery via a standard arterial catheter, and PaO2 was recorded continuously, simultaneously with analogue signals for cardiovascular and respiratory parameters from patient monitors.
Experimental protocol
Breath hold manoeuvres
In order to determine the rate of PaO2 decline during apnoea, breath hold manoeuvres lasting at least 20 s were performed at three lung volumes: end-expiration (end-expiratory lung volume, EELV, defined as functional residual capacity with 5 cmH2O PEEP), end of an inspiration corresponding to a VT of 10 ml kg−1 (VT10), and at the end of a large inspiration, corresponding to a VT of 20 ml kg−1 (VT20). Breath hold manoeuvres associated with these three lung volumes were performed six times each, in a sequence that covered each possible sequential effect, for a total of 18 breath hold manoeuvres per animal. The sequence in which breath hold manoeuvres were performed is presented in Table S1. PaO2 decline was normalized to account for small differences in body weight between animals. The steepest rate of decline measured continuously over 5 s during each breath hold manoeuvre was considered for analysis. This period of 5 s was used to maximize the interval time while avoiding the inclusion of PaO2 values below 100 mmHg, when the rate of PaO2 decline decreases due to haemoglobin desaturation, which is beyond the scope of our study.
Tidal breathing
We aimed to establish the effect of altering I:E ratios (1:2 vs 2:1, and 1:4 vs 4:1) on mean PaO2 and PaO2 oscillation amplitudes, and the potential effect of cyclical atelectasis, if present, in determining PaO2 during tidal breathing. We studied the effects of ventilation in pressure control mode, and also explored the effect of delivering the same VT gradually in volume control mode, recording PaO2 changes and determining oscillation amplitudes at the four I:E ratios. Airway pressure was monitored and controlled throughout the experiments. The two sets of tests started with either I:E of 1:2 or 1:4 in volume control mode achieving a mean PaO2 of about 130 mmHg, followed by a randomised sequence of any possible combination of I:E and pressure or volume control mode. Respiratory rates (RR) studied included 12 and 6 breaths per minute, with VT of 10 ml kg−1 and 20 ml kg−1 respectively. In total, we included 16 conditions (four I:E ratios, each in two control modes, and at two respiratory rates). During tidal breathing, once steady state had been achieved, data collected over a period of 2 min were considered for analysis. Steady state was defined as mean PaO2 not changing by more than 5 mmHg min−1.
PEEP of 5 cmH2O was used throughout the experiments in order to prevent, or at least reduce the likelihood of collapse of dependent regions at end expiration.
Computed tomography imaging
We used computed tomography (CT) to measure lung volumes as well as to estimate pulmonary atelectasis and its changes during the breath hold manoeuvres and dynamically during tidal breathing in two animals. Details of the CT images acquisition, analysis procedure, calculation of air volume and tissue mass are presented in the supplementary information.
A model of the uninjured porcine lung
We hypothesised that the uninjured lung could be modelled as a single alveolar compartment with a constant oxygen uptake. The rate of change of oxygen in this compartment is equal to the difference in the rates of uptake by the pulmonary circulation and input via ventilation during inspiration, or elimination during expiration. Details of the mathematical modelling are presented in the supplementary information.
Statistical analysis
PaO2 data recorded during the breath hold manoeuvres were analysed by means of univariate repeated measures ANOVA with lung volumes as fixed factors (IBM SPSS Statistics, Version 22.0; Armonk, NY, USA), and post hoc analysis with the Bonferroni method. A two-way ANOVA was conducted to compare the main effects of ventilation mode and I:E ratio, and their interaction on mean PaO2 and its oscillations. Ventilation mode included two levels (volume and pressure control mode), and I:E ratio consisted of two levels (either 1:2 and 2:1, or 1:4 and 4:1). Values presented are mean ± standard deviation, unless otherwise stated. Significance level was accepted at p < 0.05.
Data availability statement
Data are available upon request.
References
Hall, J. E. Guyton and Hall textbook of medical physiology. (Elsevier Health Sciences, 2010).
Kreuzer, F. & Nessler, C. Method of polarographic in vivo continuous recording of blood oxygen tension. Science 128, 1005–1006 (1958).
Folgering, H., Smolders, F. D. J. & Kreuzer, F. Respiratory oscillations of the arterial PO2 and their effects on the ventilatory controlling system in the cat. Pflugers Archiv 375, 1–7, doi:10.1007/bf00584141 (1978).
Bergman, N. A. Cyclic variations in blood oxygenation with the respiratory cycle. Anesthesiology 22, 900–908 (1961).
Williams, E. M. et al. Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome. Br J Anaesth 85, 456–459 (2000).
Baumgardner, J. E., Markstaller, K., Pfeiffer, B., Doebrich, M. & Otto, C. M. Effects of respiratory rate, plateau pressure, and positive end-expiratory pressure on PaO2 oscillations after saline lavage. Am J Respir Crit Care Med 166, 1556–1562 (2002).
Bodenstein, M., Boehme, S., Wang, H., Duenges, B. & Markstaller, K. Hints for cyclical recruitment of atelectasis during ongoing mechanical ventilation in lavage and oleic acid lung injury detected by SpO(2) oscillations and electrical impedance tomography. Exp Lung Res 40, 427–438, doi:10.3109/01902148.2014.944719 (2014).
Bodenstein, M. et al. Observation of ventilation-induced Spo2 oscillations in pigs: first step to noninvasive detection of cyclic recruitment of atelectasis? Experimental Lung Research 36, 270–276, doi:10.3109/01902140903575971 (2010).
Boehme, S. et al. Influence of inspiration to expiration ratio on cyclic recruitment and derecruitment of atelectasis in a saline lavage model of acute respiratory distress syndrome. Critical care medicine 43, e65–74, doi:10.1097/CCM.0000000000000788 (2015).
Hartmann, E. K. et al. Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model. Crit Care 16, R8, doi:10.1186/cc11147 (2012).
Herweling, A. et al. A novel technique to follow fast PaO2 variations during experimental CPR. Resuscitation 65, 71–78, doi:10.1016/j.resuscitation.2004.04.017 (2005).
Syring, R. S., Otto, C. M., Spivack, R. E., Markstaller, K. & Baumgardner, J. E. Maintenance of end-expiratory recruitment with increased respiratory rate after saline-lavage lung injury. J Appl Physiol 102, 331–339, doi:10.1152/japplphysiol.00002.2006 (2007).
Klein, K. U. et al. Transmission of arterial oxygen partial pressure oscillations to the cerebral microcirculation in a porcine model of acute lung injury caused by cyclic recruitment and derecruitment. Br J Anaesth 110, 266–273, doi:10.1093/bja/aes376 (2013).
Pfeiffer, B., Syring, R. S., Markstaller, K., Otto, C. M. & Baumgardner, J. E. The implications of arterial Po2 oscillations for conventional arterial blood gas analysis. Anesth Analg 102, 1758–1764, doi:10.1213/01.ane.0000208966.24695.30 (2006).
Shi, C., Boehme, S., Hartmann, E. K. & Markstaller, K. Novel technologies to detect atelectotrauma in the injured lung. Exp Lung Res 37, 18–25, doi:10.3109/01902148.2010.501402 (2011).
Chen, R., Farmery, A. D., Obeid, A. & Hahn, C. E. W. An all polymer fibre optic sensor for measuring rapid change in oxygen partial pressure. Proc Spie 7753, doi:10.1117/12.897591 (2011).
Chen, R. et al. Experimental investigation of the effect of polymer matrices on polymer fibre optic oxygen sensors and their time response characteristics using a vacuum testing chamber and a liquid flow apparatus. Sensors and Actuators B: Chemical 222, 531–535 (2016).
Formenti, F., Chen, R., McPeak, H., Hahn, C. E. W. & Farmery, A. D. In Vivo Validation Of A Fast Intra-Arterial Oxygen Sensor For The Detection Of Cyclical Atelectasis. Am J Respir Crit Care Med 191, A4002 (2015).
Chen, R. et al. Optimizing Design for Polymer Fiber Optic Oxygen Sensors. Sensors Journal, IEEE 14, 3358–3364 (2014).
Chen, R., Formenti, F., Obeid, A., Hahn, C. E. & Farmery, A. D. A fibre-optic oxygen sensor for monitoring human breathing. Physiological measurement 34, N71 (2013).
Formenti, F. et al. A fibre optic oxygen sensor that detects rapid PO2 changes under simulated conditions of cyclical atelectasis in vitro. Respir Physiol Neurobiol 191, 1–8, doi:10.1016/j.resp.2013.10.006 (2014).
Dubois, A. B. Alveolar CO2 and O2 during breath holding, expiration, and inspiration. J Appl Physiol 5, 1–12 (1952).
Dubois, A. B., Britt, A. G. & Fenn, W. O. Alveolar CO2 during the respiratory cycle. J Appl Physiol 4, 535–548 (1952).
Band, D. M., Wolff, C. B., Ward, J., Cochrane, G. M. & Prior, J. Respiratory oscillations in arterial carbon dioxide tension as a control signal in exercise. Nature 283, 84–85 (1980).
Baumgardner, J. E. & Syring, R. S. Maintenance of end-expiratory recruitment with increased respiratory rate after saline-lavage lung injury. J Appl Physiol 102, 2415 (2007).
Formenti, F. Conclusions on Ventilator-induced Mechanical Injuries Associated with Ventilation Using Abnormally Large Tidal Volume. Anesthesiology 124, 736, doi:10.1097/ALN.0000000000000998 (2016).
Formenti, F. Conclusions From Inverse Ratio Ventilation Studied at a Respiratory Rate of 6 Breaths/Minute. Critical care medicine 43, e323–e324 (2015).
Bergman, N. A. Effect of variations in lung volume and alveolar gas composition on the rate of fall of oxygen saturation during apnea. Anesthesiology 22, 128–129 (1961).
West, J. B. Distribution of pulmonary blood flow. Am J Respir Crit Care Med 160, 1802–1803, doi:10.1164/ajrccm.160.6.hh1-99 (1999).
West, J. B., Dollery, C. T. & Naimark, A. Distribution of Blood Flow in Isolated Lung; Relation to Vascular and Alveolar Pressures. J Appl Physiol 19, 713–724 (1964).
Brower, R., Wise, R. A., Hassapoyannes, C., Bromberger-Barnea, B. & Permutt, S. Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol (1985) 58, 954–963 (1985).
Pelosi, P. & de Abreu, M. G. Lung CT scan. The Open Nuclear Medicine Journal 98 (2010).
Formenti, F. & Farmery, A. D. Intravascular oxygen sensors with novel applications for bedside respiratory monitoring. Anaesthesia 72(Suppl 1), 95–104, doi:10.1111/anae.13745 (2017).
Formenti. F., Chen, R., McPeak, H., Murison, P. J., Matejovic, M., Hahn, C. E. W., Farmery, A. D. Intra-breath arterial oxygen oscillations detected by a fast oxygen sensor in an animal model of acute respiratory distress syndrome. British Journal of Anaesthesia 114(4), 683–688 (2015).
Acknowledgements
We are grateful to Lindsay Duckett, Agneta Roneus, Anders Nordgren, Kerstin Ahlgren, Monica Segelsjo for technical support, to Dr Luigi Camporota for help with CT image analysis, and Professors Keith Dorrington, Peter Robbins and Pierre Foex for helpful discussions. This work was supported by a Wellcome Trust Translation Award to ADF and CEWH, Swedish Heart and Lung Foundation, Swedish Research Council (K2015-99X -22731-01-4) to AL, an Oxford University Medical Research Fund to FF, and a Whitaker International Fellow Grant to NB.
Author information
Authors and Affiliations
Contributions
F.F., G.H., C.E.W.H., A.L., A.D.F. designed the experiments. F.F., N.B., R.C., H.M., D.H. performed the experiments. F.F., N.B., J.C. analysed the data. F.F., G.H., C.E.W.H., A.L., A.D.F. interpreted the data. F.F., N.B., C.E.W.H., A.L., A.D.F. contributed to financial support. F.F. wrote the manuscript. All authors read and critically revised the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Formenti, F., Bommakanti, N., Chen, R. et al. Respiratory oscillations in alveolar oxygen tension measured in arterial blood. Sci Rep 7, 7499 (2017). https://doi.org/10.1038/s41598-017-06975-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-06975-6
This article is cited by
-
Could respiration-driven blood oxygen changes modulate neural activity?
Pflügers Archiv - European Journal of Physiology (2023)
-
Mathematically arterialised venous blood is a stable representation of patient acid–base status at steady state following acute transient changes in ventilation
Journal of Clinical Monitoring and Computing (2022)
-
Bedside monitoring of lung volume available for gas exchange
Intensive Care Medicine Experimental (2021)
-
Real-time effects of PEEP and tidal volume on regional ventilation and perfusion in experimental lung injury
Intensive Care Medicine Experimental (2020)
-
Dynamic single-slice CT estimates whole-lung dual-energy CT variables in pigs with and without experimental lung injury
Intensive Care Medicine Experimental (2019)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.