Abstract
This work is focused on the fabrication and analysis of graphene-based, solution-gated field effect transistor arrays (GFETs) on a large scale for bioelectronic measurements. The GFETs fabricated on different substrates, with a variety of gate geometries (width/length) of the graphene channel, reveal a linear relation between the transconductance and the width/length ratio. The area normalised electrolyte-gated transconductance is in the range of 1–2 mS·V−1·□ and does not strongly depend on the substrate. Influence of the ionic strength on the transistor performance is also investigated. Double contacts are found to decrease the effective resistance and the transfer length, but do not improve the transconductance. An electrochemical annealing/cleaning effect is investigated and proposed to originate from the out-of-plane gate leakage current. The devices are used as a proof-of-concept for bioelectronic sensors, recording external potentials from both: ex vivo heart tissue and in vitro cardiomyocyte-like HL-1 cells. The recordings show distinguishable action potentials with a signal to noise ratio over 14 from ex vivo tissue and over 6 from the cardiac-like cell line in vitro. Furthermore, in vitro neuronal signals are recorded by the graphene transistors with distinguishable bursting for the first time.
Similar content being viewed by others
Introduction
In the field of bioelectronics, graphene is a promising candidate for very efficient, flexible, biocompatible and implantable sensors1,2,3. Graphene field effect transistors (GFETs) are the main focus of the work. In general, transistors are very interesting for bioelectronics, since when compared to microelectrode arrays (MEAs)4 they are active elements and are therefore more functional and tunable. Graphene transistors have already been shown to be extremely sensitive to changes in the gate potential in a liquid environment5. Moreover, it is possible to decrease the device’s size without impairing its performance (if the W/L ratio is preserved), which is a great advantage when compared to classical microelectrode arrays (MEAs)4. Additionally, even large areas of graphene have been proven to be both biocompatible and cytocompatible6, 7.
Additionally, in order to conduct good quality extracellular measurements reproduciblythe devices need to be identical or close to identical. However, up to now most fabrication routes for graphene-based bioelectronics are at an early development stage where devices are processed individually or in small arrays comprising only of a few devices and fabricated on a chip-scale5, 8, 9.
In recent years there have been many attempts to scale up the single-device processing to wafer-scale fabrication; some are still focused on epitaxially grown graphene10, 11, while some have attempted using chemical vapor deposition (CVD) graphene for the wafer scale fabrication of devices12,13,14. One of the main problems in this regard is the quality of CVD-grown graphene15. However, up to now, CVD graphene can be grown on Cu or Cu-Ni foils with grain sizes up to the centimeter scale16, 17, and recent advances in graphene growth show that even in cold wall CVD reactors it is possible to fabricate high quality monolayers of graphene18. However, the graphene still needs to be transferred to device-compatible substrates and the transfer process can introduce defects and consequently a low yield in functional devices19, 20.
In our previous work we demonstrated efficient transfer of graphene, which requires only 4 cm2 of the graphene-on-copper for fabrication of one 4-inch wafer with 52 devices per wafer21. This high-throughput transfer and large scale fabrication approach, combined with the cm-scale sizes of graphene domains17, will result in more reproducible performance of the GFETs.
In this work, we present a large scale fabrication of GFETs aimed for bioelectronics applications. Fabricated on a 4-inch scale, the process can be further adjusted to 6- and 8-inch processes with similar yield. Altogether, we evaluate the performance of the solution-gated GFETs (contact resistance, mobility and transconductance) depending on: (a) processing parameters, including substrate type (SiO2, HfO2, polyimide), passivation, geometric considerations and graphene channel size; (b) measurement conditions, including ionic strength of the gating solution used and applied potentials. Bio-experiments, consisting of ex vivo (heart tissue) and in vitro (HL-1 cell line and cortical neurons) recordings, prove the applicability of such graphene transistors for bioelectronics. A new passivation type, the feedline follower is introduced and argued to be better for neuronal interfacing. An electrochemical, gate leakage current induced cleaning of graphene and consecutive improvement of the GFETs performance is also investigated in the scope of this work.
Results
In order to provide a comprehensive statistical analysis and study extensive cellular recordings, we fabricate our devices on 4-inch wafers (see Fig. 1a–b). Each wafer consists of 52 chips with different layouts. The chips (see Fig. 1c) are designed and fabricated in order to measure and track the propagation of extracellular electrical signals through the cellular layer. Therefore, it is important to have a structured array of 32 devices (6 by 6 excluding four corners) with an inter-device pitch of 200 µm (see Fig. 1d). Such devices can be fabricated on any silicon technology compatible wafer. In the manuscript we present the experimental data collected from four wafers: two SiO2/Si (further denoted as Si-I and Si-II), one HfO2/Si (Hf) and one polyimide/Si (PI) (see Fig. 1f). The Si-I, Hf and PI wafers were fabricated in a top contact method, while the Si-II wafer was fabricated with graphene metallised from two sides. As stated above, the 52 chips are fabricated with different layouts in order to fulfill diverse goals. In order to investigate the influence of the graphene area’s shape on the final performance of the device, eight chips per wafer were fabricated with varied W/L ratios of graphene. As schematically shown in Fig. 1g, there are four widths (2 µm, 5 µm, 10 µm and 20 µm) and three lengths (3 µm, 8 µm and 18 µm) of the graphene channels. However, the lengths of the channels are defined by the polyimide passivation opening (HD-8820, see Methods for details), which is not a very photostructurable resist, resulting in some variation of the final length (±0.5 µm). The accurate length of each analysed device was measured via optical microscopy. In order to provide a better interface between the GFETs and neuronal cells, we designed a new type of passivation, namely the so-called ‘feedline follower’. As schematically shown in Fig. 1e, the passivation (3 µm thick polyimide) covers only the area over the metallic feedlines.
The electrical characterisation of the GFETs was performed using a Keithley 4200 semiconductor characterisation system. Drain and source electrodes of a GFET were contacted with tungsten needles and the gate was contacted via an Ag/AgCl pellet electrode inserted into an ionic solution, in our case phosphate buffered saline (PBS). The characterisation of a GFET consists of two steps: current annealing and measurement. The annealing step, was discovered during initial measurements, and is required to bring the transistor into its operative state. Failure to perform this step prevents further accurate analysis of the devices. During the annealing step, the drain-source current, IDS, is recorded, while the gate potential, VGS, is swept against the Ag/AgCl pellet electrode from 0 V to 1 V. Initial characterisation measurements of the GFETs usually indicate the charge neutrality point (e.g. Dirac point) is far within the p-doping regime (see Fig. 2a). However, every consecutive measurement brings the Dirac point to the left, until a stable position (VDirac~350 mV) is reached (see Fig. 2a–b). Once annealed, further I-V sweeps do not shift the Dirac point, nor change the channel’s resistivity, indicating a clean surface of our graphene. Usually, the larger the VGS sweep window is, the faster the curve stabilises. Previous investigations have reported a similar phenomenon based on current annealing, which is based on the atomic re-structuring of the graphene lattice22,23,24. However, it is unlikely that this effect is responsible for the observation in our case, considering the current/potential levels are too low to result in such an effect. The drain-source current density22, 23 results is on the order of 106 A·cm−2, which provides a current density, insufficient to anneal the graphene lattice, especially considering the liquid environment. Moreover, when reducing the drain-source potential to 1 mV the effect remains, although the actual channel current density is decreased to the order of 104 A·cm−2.
This is an interesting phenomenon, which, to the best of our knowledge, has not been previously reported in literature. We suggest that the effect originates from the removal of the cleanroom process contaminants (which dope the graphene into the p-regime) via an electrochemical reaction driven by the out-of-plane leakage current. Application of high VGS potentials (up to 1.4 V vs a Ag/AgCl electrode, gold feedlines passivated) increases the gate leakage current up to tens of nA (see Fig. 2c). We observed that the gate leakage current IGS increases with the gate source voltage VGS. This effect becomes more pronounced after each annealing step (see Fig. 2c). However, the gate leakage is still small compared to the drain-source current.
The removal of contaminants can result in an intermediate step, when a local doping creates a second conduction minima (pseudo Dirac point, see Supplementary Fig. S2a). Every consecutive measurement reduces the second conduction minima, finally resulting in a graphene transistor transfer curve with just one charge neutrality point (see Supplementary Fig. S2c). Evolution of the transconductance and mobility of the devices over the annealing cycles is given in the Fig. 2d. The data show that the first transfer curve is not an appropriate indicator for further data processing, but the system stabilises after the third measurement.
Following the annealing steps, the GFETs are characterised (VGS sweeping 0 V – 0.8 V; VDS = 0.1 V) and analysed for their performance, including transconductance, mobility, Dirac resistance, contact resistance and sheet resistance (see Supplementary Figs 3–4for details). The first two parameters (gm – maximum value of transconductance and µmax – maximum value of field effect mobility) are usually taken into consideration for comparison with other materials and works25. Remarkably, some of the values, like sheet resistance, RS, can be used for the rough evaluation of the GFET’s quality, while values of mobility have to be carefully examined in order to provide a correct and valuable comparison (see Supplementary Information for details).
From the equation for a transistor in a linear regime26:
we can calculate the mobility, \(\mu =\frac{L}{W}\cdot \frac{g}{{C}_{ox}{V}_{DS}}\)and the transconductance, \(g=\frac{d{I}_{DS}}{d{V}_{GS}}\). Transconductance is simply a first order derivative from the transfer curve and is the most important and direct value to evaluate the sensitivity of the transistor for potentiometric biosensor applications utilizing a graphene transistor’s channel conductivity as the sensing element. Extraction of the value of the field-effect mobility, on the other hand, is a more complex value, which requires knowledge of the interface capacitance. Specifically, it is known that graphene devices, biased via a liquid gate, undergo a very complicated gating procedure. For a proper model one has to consider the electric double layer (EDL) capacitance, CEDL, and the quantum capacitance, CQ, of the graphene itself (see Fig. 3a)27,28,29. While the CEDL can usually be approximated by a parallel-plate capacitor, the CQ is an intrinsic property of graphene and depends on the charge carrier concentration,\(\,n={(\frac{e{V}_{GS}}{\hslash {v}_{F}\sqrt{\pi }})}^{2}\), induced by the gate potential, and n*, induced by charge impurities. The concentration of induced charge impurities28, n*, is known to vary from 1 × 1011 to 1 × 1012 cm−2. An extra term, the so called air gap capacitance, Cairgap, was later proposed to be included in the model for more precise calculations30. Cairgap is valid for hydrophobic materials (such as graphene) and high ionic concentrations of the solution gate, when the usual approach would end up in an unrealistic case of ions coming too close to the graphene surface2, 30, 31. Finally, we combine all three capacitances, with the calculation details given in the Supplementary Information. In order to provide a comprehensive analysis, we measured six GFETs in a PBS titration series PBS from 10x down to 0.001x. 10x PBS is a solution has an ionic strength of 1.62 M, which would theoretically result in a Debye length of 0.24 nm, however, such values are not physically possible31. Therefore, for the highly concentrated salt solutions, the air-gap simplified model is used for the capacitance calculations. In the model, the diffuse layer breaks down for high concentrations and steric repulsion has to be considered. Nevertheless, the overall capacitance is dominated by the air gap (which takes the place of the Stern layer in our model)31. Therefore we use the simpler model, taking into account only the quantum and air gap capacitances (see Fig. 3a top panel). For PBS concentrations with a lower ionic strength we use a more complicated model that additionally takes into account the capacitance of the diffuse double layer (see Fig. 3a bottom panel). Since the quantum capacitance of the graphene depends on the number of charge carriers induced by the gate potential, the overall capacitance of the liquid-gated graphene transistor depends on the VGS potential. The overall Ctotal versus VGS plot for different PBS concentrations is given in Fig. 3b. Calculation details are given in the Supplementary Information. The plots in Fig. 3b are calculated using n* = 1 × 1011 cm−2. In order to understand the significance of n* we have plotted the calculated capacitance over 5 values of PBS concentration while changing the assumed n* from 1 × 1011 cm−2 to 1 × 1012 cm−2 (see Fig. 3c and Supplementary Fig. S5 for a more detailed plot). The resulting behaviour shows that increasing n* increases the overall capacitance value. The changes in Ctotal over n* are the highest close to the charge neutrality point, but can be neglected in the regions of maximum transconductance/mobility (see green dashed areas in Fig. 3b–c; also see Supplementary Table S1 for details).
Transfer curves from one of the GFETs are given in Fig. 3d. The Dirac point position of the GFET shifts depending on the ionic strength of the solution used as the gate, as visible in Fig. 3d. This dependency can be explained by the change of the solution’s chemical potential when changing its molarity/ionic strength. The Dirac point shift is −83 ± 17 mV/decade, from which the 60 mV/decade of the response due to changes in the chloride concentration when diluting the PBS buffers must be subtracted. The Dirac point shift of −23 ± 17 mV per decade is small compared to that previously reported14, suggesting an advantageously cleaner surface32.
In Fig. 3e the summary of the GFET’s performance in different PBS solutions is given; while the Dirac points shift due to change in chemical potential, the transconductance and mobility values are not significantly different.
Further analysis of a device’s performance is done regarding the processing parameters, i.e. substrate, width and length of the graphene area, and the type of contacts. For this purpose, over 500 GFETs from four different wafers (Si-I, Si-II, Hf, PI) with different lengths and widths were measured and analysed. The ionic solution and VDS potential were kept constant for every measurement. The outcome is that the transconductance is linearly dependent on the width-to length (W/L) ratio of the device, as previously reported33. In Fig. 4a the values of transconductance over the W/L ratio of the graphene channel are plotted from devices fabricated on one wafer, Si-II. The fitted curve shows a linear trend (with a correlation coefficient of around 0.99). In order to show more detailed width and length dependency, we averaged the transconductance values for each width-to-length combination. The result can be seen in Fig. 4b, reproducing the above-described trend. We therefore will use the proposed normalisation of the transconductance to a number of squares (one square (□) is when W/L = 1, see Supplementary Fig. S1)33. Such normalisation brings more comparable values important to describe and compare intrinsic properties of GFETs. The other wafers were analysed in a similar way and the averaged fitting curves, which show the slope of the transconductance are given in Supplementary Fig. S9. From these dependencies we can extract the normalised values of transconductance, denoted further in mS·V−1·□, and plot in statistical details in Fig. 4c. Interestingly, in our case the mean values of the normalised transconductance do not depend strongly on the underlying substrate; however, minor differences are visible. The mean values of transconductance, normalised to VDS and number of squares (□), for all five wafers are in the range of 1-2 mS·V−1·□.
In order to understand the field effect mobility values (measured and calculated with an ionic strength of 162.7 mM), the values are averaged for each wafer (see Fig. 5a). Since the distribution of the data is not Gaussian, but skewed towards lower values, the detailed histogram plots are given in Supplementary Fig. S8. The same CVD grown graphene was used for all four wafers, and the mobility values are quite similar for all wafers (in the range of 500–1000 cm2·V−1·s−1). However, one can see that there are rare occurrences of extra-large mobility values especially for the HfO2 and polyimide substrates (Fig. 5a). In order to understand the origin of such large mobilities, we plot the data for each transistor from each wafer over the area of the graphene channel (Fig. 5b). From the Fig. 5b it becomes clear that the extremely high mobility values only happen in devices with very small channel areas (below 100 µm2). One of the possible explanations of this phenomena is a finite crystallinity of the graphene. Regardless of the grain sizes of the CVD grown graphene, in smaller devices there are fewer grain boundaries, reaching a situation when a GFET consists of a single graphene crystal. In this case we see the drastic increase in that transistor’s charge carrier mobility. While for the GFETs with channels above 100 μm2 in area, the chance of grain boundaries increases, limiting electrical performance of the GFETs34, 35. The principle was also shown when boundaries were specifically introduced for ion channel sensing applications36. Another explanation for the observed mobility values is substrate-induced scattering, which constricts the electrical properties of even single crystalline devices, as visible on the example of SiO2-based devices. Although the devices on SiO2 substrates have the largest average mobility (750 ± 350 cm2·V−1·s−1), the SiO2 substrate results in a suppression of the performance37 compared to HfO2 and polyimide substrates, where the value can reach up to 4.9 × 103 cm2·V−1·s−1.
The last two important parameters for characterisation of the GFETs are the contact resistance, RC, and transfer length, LT. The transmission line measurement technique (TLMT) has been used to determine the parameters38. Details of the calculations are given in the Supplementary Information. We analysed the difference in the contact resistance for wafer Si-I (top contacted) and Si-II (double contacted) and the results can be seen in Supplementary Fig. S7. The mean value of both wafers’ sheet resistances are: RS, Si-I = 1550 ± 820 Ω and RS, Si-II = 1210 ± 1040 Ω. Clearly double side contacting reduces the contact resistance and therefore the overall sheet resistance of the GFETs. The computed transfer length for the wafers are: LT, Si-I = 8.5 ± 2.2 µm and LT, Si-II = 3.6 ± 2.2 µm. The transfer length is the path a charge carrier has to travel underneath the contact area before transfer to the feedline. Decreasing transfer length is important for further miniaturisation of the devices. This shows that the transfer length could be reduced by more than a factor of 2 using double contacted graphene.
Table 1 is provided in order to directly compare the data from previously published works5, 8, 14, 30, 33, 39,40,41 when the geometrical and environmental factors are taken into account. Interesting to see is that first of all just voltage normalised transconductance values can be misleading, and the values are extremely over/underestimated. When the values are further normalised per number of squares, the final performance shows a similar trend across publications.
In order to show the applicability of the devices for bioelectronics applications, the devices were encapsulated and prepared for cell culture (see Supplementary Information). The devices were later measured at the custom-built multi-channel measurement set-up, the principle of which is schematically shown in Fig. 6a. The measurement routine consists of two steps. Firstly, calibration is done by applying a sine signal with a certain amplitude, Vin, to the gate electrode, while source-drain signal amplitude, Vout, is monitored and the overall amplification factor \({A}_{V}={V}_{out}/{V}_{in}\) is calculated. Next, in the recording/time series step, the VDS is simply measured, and the changes (∆VDS) are transformed into ∆VGS by dividing by AV (see Fig. 6a). Every further presented time series data shows the actual gate potential fluctuations (∆VGS).
Afterwards, an embryonic heart tissue is placed on the chip’s surface (see Fig. 6b). A Ag/AgCl pellet electrode is placed as close to the tissue as possible in order to provide a stable potential through a small amount of ionic solution (supplementary medium). The time trace recording from one of the channels (GFETs) is presented in Fig. 6c showing repetitive spikes up to 7 mV with a beat rate of 30–40 beats per minute (bpm). When the action potentials (APs) from one channel are extracted and averaged, they result in a very distinct shape with visible Q, R, S and slight T regions of the electrocardiogram (Fig. 6d). The heart tissue measurements show an excellent applicability of the GFETs for ex vivo bioelectronics. The overall signal-to-noise ratio (SNR) of the measurements is up to 17, while considering the noise as twice the median absolute distribution (MAD, see Supplementary Information for discussion).
Cardiomyocyte-like cells (HL-1 cell line) are further cultured on the chips’ surface (see Fig. 6e). A typical time trace recording from a GFET with HL-1 action potentials is shown in Fig. 6f. The cells are beating (producing repetitive APs that propagate through the whole cellular layer) with a rate over 25 bpm and an amplitude of 1.2 ± 0.2 mV. Considering the 2·MAD noise level of 200 µV, the overall SNR is 6 ± 1, which is in the same sensitivity range as reported previously40, 42. The shape of the APs is shown in Fig. 5g, where over 115 consecutive spikes are averaged and the average AP is shown in blue. The shape of the action potential, in agreement with previous works, represents a very good sealing between the cell and the transistor43, 44.
Further, cortical neurons were cultured on top of the chips (details are given in Methods) with an approximate density of 1500 cells per mm2. The neuronal network was cultured for at least 14 days in vitro (DIV14) until mature, when the cultured neurons produce spontaneous APs that can propagate through the network. As expected, the extracellular neuronal APs are one or two orders of magnitude smaller than those of heart tissue45. Nevertheless, we were able to record the APs and even bursting activity of neuronal networks with the GFETs (Fig. 6h). More time trace recordings (including one after killing the cells) and live-dead fluorescence images can be found in the Supplementary Fig. S10. To our knowledge, such neuronal bursting activity recorded by graphene transistors is reported here for the first time. The average action potential (n = 77) is presented in Fig. 5i, showing the average amplitude around 630 µV. The noise, calculated as 2·MAD results in the value of 200 µV. Therefore, the resulting SNR is above 3.
Important to consider in further comparison is that in all our SNR measurements we use 2 × MAD instead of root mean square (RMS) for the noise value and only a 50 Hz filter applied to the recordings to remove the power line hum and to keep the signal as undisturbed as possible. In addition to that, there is a 3 kHz anti-aliasing low-pass filter installed in the amplifier system. However, an appropriate filter and use of the RMS value would result in the SNR estimation up to 5 for neuronal recordings, 10 for HL-1s and 25 for heart tissue (see Supplementary Information for details).
Understanding the shape and amplitude of the recorded neuronal action potentials is a complex task, considering that different parts of a neuronal network produce different kinds of potentials46. Moreover, the final signal shape depends on the signal transport from a cellular membrane to a transistor. Here the important factor is the so-called cell-chip coupling47. Since the cells are alive and dynamically growing, the coupling might be different from culture to culture and from chip to chip42, 44, 47,48,49. Nevertheless, our neuronal recordings from graphene transistors are in good accordance with previously published neuronal AP shape data8.
An important discussion we would like to address at the end of this work is the importance of the passivation. The most common way of passivating the transistors for bioelectronics consists of covering the whole chip’s surface except for the active area (see Fig. 7a). The openings might be useful for recording from such cells like HL-1s50, which form a large confluent layer all-over the surface, create a sealed environment and therefore increase the signal51. Neuronal networks, in contrast, do not form confluent layers, but rather grow a large network of neurites. The neurites could be as small as 1 µm in diameter. Therefore, neurons usually do not cover the entire passivation opening, and the large gap distance is compounded by unsealed areas at the cell edges (see Fig. 7b–c).
For this work we designed a new kind of passivation, the so-called feedline follower, where the passivation covers only the area over the metallic feedlines, as it was shown in Fig. 1d. We believe that using this passivation technique, helps to create a better interface between graphene gates and neurons by preventing membrane bending stresses as the cell approaches the graphene and therefore reduces the gap distance between the neuron and the gate (Fig. 7e–f).
Moreover, there is always a trade-off between low-noise recording interface and good cell-sensor coupling. Considering that the GFETs’ multichannel measurement setup exhibits large noise, we cannot afford to increase the noise by creating a seal. At the same time, graphene is a purely two-dimensional material and it is important to bring the cell body as close to the graphene’s surface as possible. We believe that such new passivation is more suitable for the graphene-based devices, since the neuronal culture then grows consistently closer to the level of the graphene gates.
Methods
Graphene growth and device fabrication
The graphene was CVD grown on 25 µm thick copper foils in an Ar/H2/CH4 gas mixture (see Supplementary Fig. S12 for Raman spectra). A thin layer of poly(methyl methacrylate) (PMMA) was used as a support layer during the transfer. In order to not waste the graphene layer, we used the modified, high-throughput transfer technique21. The graphene was transferred onto the wafer with pre-fabricated Au/Ti markers. AZ-5214 photoresist (MicroChemicals GmbH) was then spin-coated (3000 rpm), soft baked (110 °C for one minute), exposed to i-line UV light with a dose of 55 mJ/cm2, developed in 0.26% TMAH solution, and was used to protect the graphene active areas during exposure to oxygen plasma (300 W, 200 sccm, 5 minutes). The stack of 10 nm Ti and 90 nm Au was e-beam assisted evaporated on the wafer through a pre-defined structure of lift-off resists. For this purpose, LOR-3B (MicroChemicals GmbH) was spin-coated (3000 rpm) and soft baked (150 °C for 5 minutes) on top of another resist, nLOF-2020 (MicroChemicals GmbH), spin-coated (3000 rpm) and soft baked (100 °C for 2 minutes) in advance. The resists were exposed to i-line UV light at a dose of 40 mJ/cm2, post-exposure baked (110 °C for 1 minute) and developed in 0.26% TMAH. Photostructurable polyimide, HD8820 (HD Microsystems) was used in the last step to form the passivation. Spin-coated at 5000 rpm, soft-baked at 120 °C (with a slow ramp), exposed to 250 mJ/cm2 i-line UV light, developed in 0.26% TMAH for 80 seconds and hard baked (double slow ramp in N2 atmosphere: 4 °C/min up to 200 °C, 30 minutes hold; followed by 2.5 °C/min up to 350 °C, 30 minutes hold; slow cooling down to room temperature), the polyimide formed a pinhole-free, 3 µm thick passivation. Post-cleanroom treatments, such as device encapsulation protocols are given in the Supplementary Information.
HL-1 cell culture
The cardiomyocyte-like cell line HL-1 was cultured in T25 flasks51. Prior to the seeding, the chips were cleaned with 70% ethanol and coated with fibronectin/gelatin solution (5 µg/mL and 0.2 mg/mL, respectively). When reaching 100% confluency, the cells were passaged and seeded on top of the GFETs at 200 cells/mm2. The chips were then placed in an incubator (37 °C and 5% CO2) for the cells to mature. Claycomb medium, supplemented with 10% fetal bovine serum, 100U/ml-100µg/ml penicillin-streptomycin, 0.1 mM norepinephrine and 2 mM L-glutamine was exchanged every day (100%) and two hours before the measurements.
Heart tissue preparation
The heart tissue was prepared by dissecting embryonic tissue from an E18 Wistar rat. The heart of an embryo is quickly isolated, washed in Hank’s balanced salt solution (HBSS), then stored and measured in supplemented Claycomb medium (see HL-1 cell culture).
Neuronal culture
The primary cortical neurons were isolated from E18 Wistar rats52. Prior to culturing the cells on a chip, a glass ring was mounted onto the chip to form a culture container and the surface of the chip was coated with GpECM (4 µg/mL Gelatin, 0.01 mg/mL poly-D-lysine and 0.0924 mg/mL extracellular matrix in Gey’s Balanced Salt Solution) for improved cellular adhesion. The cells were diluted in Neurobasal medium (Life Technologies), supplemented with B27 (1% (v/v), Gibco), L-glutamine (0.5 mM, Gibco) and Gentamicin (0.05 mg/mL), and plated on top of the chip with an approximate density of 1500 cells per mm2. Chips were kept in an incubator (37 °C and 5% CO2) and the supplemented Neurobasal medium was exchanged with 100% fresh supplemented medium two hours after the plating then with 50% fresh supplemented medium twice per week and one day before the measurements. The neurons were grown until at least DIV14. Measurements were performed on DIV 14–26.
Live-dead imaging
Live-Dead staining was performed using 1 µg/ml Calcein-AM and 2 µM Ethidium Homodimer (both Life Technologies) in supplemented cell growth medium to stain live and dead cells in green and red, respectively. Cells and dyes were incubated for 15 minutes in a 37 °C incubator or on a 37 °C hot plate (if performed after the measurements). The samples were observed using an Axio Imager Z1 microscope (Carl Zeiss).
Fixation and imaging
In order to see the topography of the neuronal network, a high-resolution image is required. We used scanning electron microscopy (SEM) to observe the outgrowth of neurons on the chip surface. It is important to use a special preparation technique in order to image biological specimens due to their normal existence in an aqueous environment and lack of conductivity53. After the culture, the samples are chemically fixed using a 3.2% glutaraldehyde solution in PBS for 15 minutes at room temperature. Following that dehydration is performed in a series of ethanol washing steps (from 10% to 100% of ethanol concentration). The samples are then stored in 100% ethanol until they are dried via the CO2 critical point drying (CPD) technique. In order to improve the charge flow, the samples were sputtered with approximately 10 nm of platinum prior to the SEM imaging. Figure 7 and Supplementary Fig. S13 show examples of the neuronal culture on top of GFET chips.
If not stated otherwise, all chemicals were purchased from Sigma Aldrich. The experiments were done with the approval of the Landesumweltamt für Natur, Umwelt und Verbraucherschutz Nordrhein-Westfalen, Recklinghausen, Germany, number 84–02.04.2015.A173.
Data availability
The data that support the findings of this study are available from the corresponding author on request.
References
Sharma, B. K. & Ahn, J.-H. Graphene based field effect transistors: Efforts made towards flexible electronics. Solid. State. Electron. 89, 177–188 (2013).
Hess, L. H. & Seifert, M. & Garrido, J. a. Graphene Transistors for Bioelectronics. Proc. IEEE 101, 1780–1792 (2013).
Kuzum, D. et al. Transparent and flexible low noise graphene electrodes for simultaneous electrophysiology and neuroimaging. Nat. Commun. 5, 5259 (2014).
Spira, M. E. & Hai, A. Multi-electrode array technologies for neuroscience and cardiology. Nat. Nanotechnol. 8, 83–94 (2013).
Hess, L. H. et al. High-transconductance graphene solution-gated field effect transistors. Appl. Phys. Lett. 99, 33503 (2011).
Bendali, A. et al. Purified Neurons can Survive on Peptide-Free Graphene Layers. Adv. Healthc. Mater. 2, 929–933 (2013).
Veliev, F., Briançon-Marjollet, A., Bouchiat, V. & Delacour, C. Impact of crystalline quality on neuronal affinity of pristine graphene. Biomaterials 86, 33–41 (2016).
Cheng, J. et al. Flexible Solution-Gated Graphene Field Effect Transistor for Electrophysiological Recording. J. Microelectromechanical Syst. 23, 1311–1317 (2014).
Cheng, Z. et al. Sensitivity Limits and Scaling of Bioelectronic Graphene Transducers. Nano Lett. 13, 2902–2907 (2013).
Lin, Y.-M. et al. Science Podcast. Science (80-.). 327, 734–734 (2010).
Hwang, W. S. et al. Graphene nanoribbon field-effect transistors on wafer-scale epitaxial graphene on SiC substrates a. APL Mater. 3, 11101 (2015).
Avsar, A. et al. Toward Wafer Scale Fabrication of Graphene Based Spin Valve Devices. Nano Lett. 11, 2363–2368 (2011).
Smith, A. D., Vaziri, S., Rodriguez, S., Östling, M. & Lemme, M. C. Large scale integration of graphene transistors for potential applications in the back end of the line. Solid. State. Electron. 108, 61–66 (2015).
Vieira, N. C. S. et al. Graphene field-effect transistor array with integrated electrolytic gates scaled to 200 mm. J. Phys. Condens. Matter 28, 85302 (2016).
Wang, X. et al. Large-Scale Synthesis of Few-Layered Graphene using CVD. Chem. Vap. Depos. 15, 53–56 (2009).
Wang, C. et al. Growth of Millimeter-Size Single Crystal Graphene on Cu Foils by Circumfluence Chemical Vapor Deposition. Sci. Rep. 4, 1–5 (2014).
Wu, T. et al. Fast growth of inch-sized single-crystalline graphene from a controlled single nucleus on Cu–Ni alloys. Nat. Mater. 15, 43–47 (2015).
Bointon, T. H., Barnes, M. D., Russo, S. & Craciun, M. F. High Quality Monolayer Graphene Synthesized by Resistive Heating Cold Wall Chemical Vapor Deposition. Adv. Mater. 27, 4200–4206 (2015).
Kang, J., Shin, D., Bae, S. & Hong, B. H. Graphene transfer: key for applications. Nanoscale 4, 5527–5537 (2012).
Liang, X. et al. Toward clean and crackless transfer of graphene. ACS Nano 5, 9144–9153 (2011).
Kireev, D. et al. High throughput transfer technique: Save your graphene. Carbon N. Y. 107, 319–324 (2016).
Moser, J., Barreiro, A. & Bachtold, A. Current-induced cleaning of graphene. Appl. Phys. Lett. 91, 4–6 (2007).
Hertel, S. et al. Current annealing and electrical breakdown of epitaxial graphene. Appl. Phys. Lett. 98, 212109 (2011).
Kumar, P. & Kumar, A. Carrier type modulation in current annealed graphene layers. Appl. Phys. Lett. 104, 83517 (2014).
Khodagholy, D. et al. High transconductance organic electrochemical transistors. Nat. Commun. 4, 2133 (2013).
Schwierz, F. Graphene transistors. Nat. Nanotechnol. 5, 487–96 (2010).
Luryi, S. Quantum capacitance devices. Appl. Phys. Lett. 52, 501–503 (1988).
Xia, J., Chen, F., Li, J. & Tao, N. Measurement of the quantum capacitance of graphene. Nat Nanotechnol 4, 505–509 (2009).
Israelachvili, J. N. In Intermolecular and Surface Forces 291–340 (Elsevier, 2011). doi:10.1016/B978-0-12-375182-9.10014-4.
Dankerl, M. et al. Graphene Solution-Gated Field-Effect Transistor Array for Sensing Applications. Adv. Funct. Mater. 20, 3117–3124 (2010).
Wang, H. & Pilon, L. Accurate Simulations of Electric Double Layer Capacitance of Ultramicroelectrodes. J. Phys. Chem. C 115, 16711–16719 (2011).
Fu, W. et al. Graphene transistors are insensitive to pH changes in solution. Nano Lett. 11, 3597–3600 (2011).
Kireev, D. et al. Graphene field effect transistors for in vitro and ex vivo recordings. IEEE Trans. Nanotechnol. 1–1 doi:10.1109/TNANO.2016.2639028 (2016).
Yasaei, P. et al. Chemical sensing with switchable transport channels in graphene grain boundaries. Nat. Commun. 5, 4911 (2014).
Kochat, V. et al. Magnitude and Origin of Electrical Noise at Individual Grain Boundaries in Graphene. Nano Lett. 16, 562–567 (2016).
Veliev, F. et al. Sensing ion channels in neuronal networks with graphene transistors. 1–37 (2017).
Chen, J.-H., Jang, C., Xiao, S., Ishigami, M. & Fuhrer, M. S. Intrinsic and extrinsic performance limits of graphene devices on SiO2. Nat. Nanotechnol. 3, 206–209 (2008).
Schroder, D. K. In Semiconductor Material and Device Characterization 127–184 (John Wiley & Sons, Inc., 2005). doi:10.1002/0471749095.ch3
Ohno, Y., Maehashi, K., Yamashiro, Y. & Matsumoto, K. Electrolyte-gated graphene field-effect transistors for detecting ph and protein adsorption. Nano Lett. 9, 3318–3322 (2009).
Blaschke, B. M. et al. Flexible graphene transistors for recording cell action potentials. 2D Mater. 3, 25007 (2016).
Brown, M. A., Crosser, M. S., Leyden, M. R., Qi, Y. & Minot, E. D. Measurement of high carrier mobility in graphene in an aqueous electrolyte environment. Appl. Phys. Lett. 109, 93104 (2016).
Eschermann, J. F. et al. Action potentials of HL-1 cells recorded with silicon nanowire transistors. Appl. Phys. Lett. 95, 83703 (2009).
Sprössler, C., Denyer, M., Britland, S. & Knoll, W. & Offenhäusser, a. Electrical recordings from rat cardiac muscle cells using field-effect transistors. Phys. Rev. E. Stat. Phys. Plasmas. Fluids. Relat. Interdiscip. Topics 60, 2171–2176 (1999).
Schottdorf, M., Hofmann, B., Kätelhön, E., Offenhäusser, A. & Wolfrum, B. Frequency-dependent signal transfer at the interface between electrogenic cells and nanocavity electrodes. Phys. Rev. E - Stat. Nonlinear, Soft Matter Phys. 85, 31917 (2012).
Pine, J. Recording action potentials from cultured neurons with extracellular microcircuit electrodes. J. Neurosci. Methods 2, 19–31 (1980).
Stuart, G., Spruston, N., Sakmann, B. & Häusser, M. Action potential initiation and backpropagation in neurons of the mammalian CNS. Trends Neurosci. 20, 125–131 (1997).
Fromherz, P. Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane. Eur. Biophys. J. 28, 254–258 (1999).
Ingebrandt, S., Yeung, C. K., Krause, M. & Offenhäusser, A. Neuron-transistor coupling: Interpretation of individual extracellular recorded signals. Eur. Biophys. J. 34, 144–154 (2005).
Dankerl, M. et al. Diamond transistor array for extracellular recording from electrogenic cells. Adv. Funct. Mater. 19, 2915–2923 (2009).
Czeschik, A. et al. Nanostructured cavity devices for extracellular stimulation of HL-1 cells. Nanoscale 7, 9275–81 (2015).
Claycomb, W. C. et al. HL-1 cells: a cardiac muscle cell line that contracts and retains phenotypic characteristics of the adult cardiomyocyte. Proc Natl Acad Sci USA 95, 2979–2984 (1998).
Brewer, G. J., Torricelli, J. R., Evege, E. K. & Price, P. J. Optimized survival of hippocampal neurons in B27-supplemented Neurobasal, a new serum-free medium combination. J. Neurosci. Res. 35, 567–76 (1993).
Santoro, F. et al. Interfacing electrogenic cells with 3D nanoelectrodes: Position, shape, and size matter. ACS Nano 8, 6713–6723 (2014).
Acknowledgements
We are grateful to Tianru Wu for graphene growth, Bettina Breuer for neuronal preparation, Sridhar Krishna Chander for heart tissue preparation and Ivan Bobrinetskiy for critical proof-reading of the manuscript. The work was supported by Helmholz-CAS JRG funding.
Author information
Authors and Affiliations
Contributions
D.K., B.W. and A.O. conceived the idea and designed the experiments. D.K. fabricated the devices. D.K. and M.B. performed electrical measurements. D.K., S.S. and V.M. performed biological experiments. D.K., M.B., W.F. and B.W. contributed to GFETs analysis. V.M. contributed to interpretation of biological experiments. The manuscript was written through contributions of all authors. All authors have given approval to the final version of the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kireev, D., Brambach, M., Seyock, S. et al. Graphene transistors for interfacing with cells: towards a deeper understanding of liquid gating and sensitivity. Sci Rep 7, 6658 (2017). https://doi.org/10.1038/s41598-017-06906-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-06906-5
This article is cited by
-
Active Micro-Nano-Collaborative Bioelectronic Device for Advanced Electrophysiological Recording
Nano-Micro Letters (2024)
-
Metaplastic and energy-efficient biocompatible graphene artificial synaptic transistors for enhanced accuracy neuromorphic computing
Nature Communications (2022)
-
Biogenic synthesis of reduced graphene oxide from Ziziphus spina-christi (Christ’s thorn jujube) extracts for catalytic, antimicrobial, and antioxidant potentialities
Environmental Science and Pollution Research (2022)
-
Fabrication, characterization and applications of graphene electronic tattoos
Nature Protocols (2021)
-
Electrolyte-gated transistors for enhanced performance bioelectronics
Nature Reviews Methods Primers (2021)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.