Abstract
Recently, radar sensors have been extensively used for vital sign monitoring in dogs, owing to their noncontact and noninvasive nature. However, a public dataset on dog vital signs has yet to be proposed since capturing data from dogs requires special training and approval. This work presents the first ever ultra wideband radar-based dog vital sign (UWB-DVS) dataset, which was captured in two independent scenarios. In the first scenario, clinical reference sensors are attached to the fainted dogs, and data from UWB radar and reference sensors are captured synchronously. In the second scenario, the dogs can move freely, and video recordings are provided as a reference for movement detection and breathing extraction. For technical validation, a high correlation, above 0.9, is found between the radar and clinical reference sensors for both the heart rate and breathing rate measurements in scenario 1. In scenario 2, the vital signs and movement of the dogs are shown in the form of dashboards, demonstrating the long-term monitoring capability of the radar sensor.
Similar content being viewed by others
Background & Summary
Adoption of pets in the high-income countries has become so prevalent that pets are considered to be the family members and given special care1. In particular, dogs have a special attachment to humans, and due to their friendly and supportive nature, they are termed “man’s best friend”. The prior literature supports the rationale that interaction with a therapy dog significantly reduces the level of stress among professionals with difficult jobs2. Owing to the multi-fold benefits of petting a dog, statistics indicate that the number of pet dogs is increasing in developed countries, which is raising concerns related to the health and well-being of dog3. Unlike humans, dogs cannot express their health status easily and therefore require special care. Vital signs (VS), which include the breathing rate (BR) and heart rate (HR), are amongst the key markers of a dog’s well-being4. Research indicates that a substantial rise or fall in HR or BR can be used to assess the health condition and emotional state of dogs5,6.
Among the available VS monitoring sensors, radar offers a noncontact and noninvasive solution. Among different radar technologies, impulse radio ultrawideband (IR-UWB) radar is tolerant of ambient noise and multipath effects, making it well suited for home use. In the literature, IR-UWB radar has shown its usefulness in several short-range applications, such as gesture recognition7,8, fall detection9 and VS measurement10.
The history of measuring dogs’ vital signs (DVS) using radar dates to 1975 when Lin11 extracted the breathing rate of dogs using microwaves. At present, a considerable amount of work has been performed for radar-based non-contact and non-invasive VS measurement of DVS1,12,13. For example, Wang et al.5 demonstrated VS monitoring of dogs and cats using UWB radar. Similarly, several other researchers have also considered DVS monitoring using radar1,13.
Currently, several open-source datasets of radar-based human VS exist in the literature. A dataset of heart movement recorded with radar along with a synchronized references sensor was proposed by Shi et al.14. Another dataset with clinical verification for human VS was proposed by Schellenberger and coworkers15. In addition to that, children VS dataset also exists16. While a few radar-based human VS datasets exist in the literature, radar-based dogs VS and related activity datasets are still lacking. VS extraction for human and dogs are currently being studied separately due to several differences. Consequently, a dedicated dogs VS dataset is also required.
UWB-DVS provides the first ever VS dataset of dogs acquired using UWB radar and reference sensors simultaneously. The off-the-shelf (UWB) radar sensor opted in this study comprises of nearly “all-digital” components and have minimal radio frequency components, making the circuitry simple. Moreover, UWB radars can function effectively in environments with radio frequency (RF) noise, such as homes and offices. To provide rich information related to dogs’ vital signs and behavior, two scenarios are created as shown in Fig. 1. The details of each scenario are as follows
-
Scenario 1 (Controlled environment with fainted dogs): Data from fainted dogs in the operating room are collected using radar and clinical reference sensors as shown in Fig. 1. Existing studies often consider VS extraction from fainted dogs5. In this work, general anesthesia along with Propofol as an additional induction agent, was used to induce unconsciousness in the dogs.
-
Scenario 2 (Uncontrolled environment with awake dogs): The dog is kept unconstrained inside the Intensive Care Unit (ICU) chamber and data are captured for 30 minutes. Since the dog is awake and conscious, Electrocardiogram (ECG) is not attached in this scenario; instead, a camera is attached to observe VS and movement. The second scenario can provide a continuous personalized VS measurement method for a dogs. To show the continuous monitoring solution, we also propose a dashboard for scenario 2, showing the radar observed dog’s movements and VS measurements.
Methods
Use-cases of both scenarios
Both scenarios have individual importance for DVS monitoring applications. The data corresponding to Scenario 1 can be used to perform preclinical validation of DVS extraction algorithms. It is common practice in literature to benchmark the algorithms on the fainted dogs in the clinical environment5. The radar and reference sensors are synchronized in time so that the error and correlation between the two sensors can be computed.
On the other hand, scenario 2 can be considered as a daily monitoring use-case scenario. Long-term observations can be used to monitor movements, frequency of restlessness and VS for a prolonged period of time. Although the clinical reference data are not available in scenario 2 since clinical sensors worn on the bodies of moving dogs are not recommended by medical experts, the captured data can be used to determine the personalized baseline of each dog, and sudden change in VS or movement history can be used as an early indicator of a hazardous situation. In addition to that, camera sensor can be used to observe the movements being made by the dog. To evaluate the accuracy of a specific VS extraction algorithm, scenario 1 must be considered.
Data Acquisition Environments and Hardware
Data acquisition environments
The data acquisition environments and the apparatus are shown in Fig. 2. For scenario 1, shown in Fig. 2a, the data are collected in the operating room and the reference sensors were connected to the fainted dog using ECG electrodes. The radar sensor and camera are installed at a distance of 0.3 meters as shown in Fig. 2. The second scenario is shown in Fig. 2b, where the dog is awake and can make movements (freely) inside the ICU chamber. Since the installation of body worn sensor is not feasible when the dog is awake, a camera sensor is attached as a reference which can show the movement of the dog and the movement of the lungs when the dog is at rest.
Reference sensors
For scenario 1, a clinical reference sensor for HR and BR extraction was attached to the body of each dog as shown in Fig. 2a. We used a BM7Vet Pro ECG sensor, manufactured by Bionet Co., Ltd, shown in Fig. 2c. The device is a clinically approved veterinary VS monitoring sensor, which is extensively used at the health care facilities throughout the world.
For scenario 2, video recordings for each dog are included in the UWB-DVS data descriptor. Veterinarians often measure the BR and HR of dogs by manually observing the pulse for 10 seconds and multiply the result by six. From video recordings, one may approximate the BR in a similar way. The video recordings additionally act as ground-truth values for the dogs’ movement history quantification.
Radar sensor
In this study, we used a Xethru-X4 IR-UWB radar device designed by Novelda, Norway, consisting of a single transmitter and receiver pair as shown in Fig. 2d. Xethru radar has been extensively used in the literature for several applications including human VS measurement17, dog VS measurement5,18 and gesture recognition7,19. The radar operates at a center frequency of 7.29 GHz. The rest of the settings are summarized in Table 1.
Radar and reference sensor synchronization
The clocks of radar and reference sensors were synchronized up to fractions of seconds. The medical device operator and the radar engineer synchronized and verified the timestamps. The radar data were sampled at 50 FPS (see Table 1), whereas the reference data were sampled at 1 FPS. Prior to statistically validating the data, the radar extracted vital signs were averaged to 1 FPS in order to match the reference sensor data.
Radar Signal Modeling
The dog’s skin vibrates continuously because of heart and lungs movement. This vibration x(t) can be defined as20
where xo represents the mean value of distance around which the body of dog vibrates. The terms Abr and Ahr represent the amplitudes of the signal generated by the movements of the lungs and heart respectively. The corresponding movement frequencies for the heart and lungs are represented as fbr and fhr respectively. With the dog as the only moving object in the radar cross-section (RCS) as shown in Fig. 2, the impulse response of the system will be
Here, the impulse response corresponding to the dog vital signs is termed as \({a}_{vs}\delta (\tau -{\tau }_{vs}(t))\) and the clutter will is
where ai and ti respectively represent the amplitude and time of the ith reflection. With c being the speed of light, the time delay between the transmitted and received signals τvs is represented as:
where τbr and τhr represent the time delays due to the BR and HR, respectively. The signal at the receiver of radar, represented in Fig. 1 as srx(t), will be the result of convolution of the transmitted signal Str(t) and the system impulse response h(τ,t)
Here, Stx(τ) is the shape of the transmitted signal. Equation 6 shows a single pulse being transmitted by radar. Several pulses are often transmitted, and the received response is stacked as a two dimensional (2D) matrix which (in discrete form) can be expressed as
where R[n,m] is a 2D matrix with n rows and m columns, termed as slow-time and fast-time respectively. Note that each row of Eq. 7 contains the vital sign reflections for one transmitted frame as expressed in 6. These frames are repeated continuously and in our case, 50 frames per seconds are being saved, as reported in Table 1.
Dogs Vital Sign Extraction
The vital sign extraction algorithms for scenarios 1 and 2 are illustrated in Fig. 3a and b, respectively. The 2D matrix shown in Eq. 7 serves as the input to the algorithm in both scenarios.
For the static case, we removed the DC component of the signal prior to determining the movement made in front of the radar. Afterward, the clutter term c[m] consisting of static reflections was suppressed by deploying a loop-back recursive filter7,16.The target (dog’s) position was determined by calculating the variance of the 2D radar data matrix R[n,m], and the distance showing the highest variance was selected as the target range bin.
After determining the location of the dog, the fast Fourier transform (FFT) was used to quantify the frequency of body vibrations. The BR and HR of a normal dog range between 10–40 Hertz (Hz) and 60–160 Hz respectively. Consequently, two bandpass filters (BPF) were applied in the frequency domain to separate the BR and HR. The whole operation was repeated over a sliding window for continuous monitoring purposes.
The vital signs extraction procedure for scenario 2 is also based on the similar concept opted in scenario 1 however, prior to vital sign extraction, the movement was quantified and plotted along with the vital signs as illustrated in Fig. 3b. The movement of dog under test was determined by taking the absolute sum of the difference of two consecutive frames21
where Rcr is the clutter-removed version of radar data matrix R described in Eq. 7, and the amplitude of MI quantifies the movements of the dog. As stated earlier, the terms n and m represent the fast-time and slow-time respectively. The magnitude of MI defines whether the dog is absent, moving or resting. As shown in Fig. 3, stable vital signs can be observed only when the dog is resting. The dashboard shows the insight about the movement and dogs’ VS concurrently. For instance, any abrupt change or anomaly in the dog’s VS when the movement index is considerably low may be an early indicator of a possible medical emergency.
Data acquisition procedure and protocols
Data collection was performed at the Nowon N animal hospital, Seoul, South Korea. All the procedures and protocols were approved by the Hanyang University Institutional Animal Care and Use Committee (HYU-IACUC;2022-0252), and the researchers were strictly advised to follow the established guidelines throughout the process. Two medical experts and a radar engineer supervised the data capturing process, and the data were selected by their mutual approval. Overall data acquisition was supervised by the corresponding author. As stated earlier, we captured data in two different environments, and the procedure and protocol for each environment are discussed individually in subsections for convenience.
Scenario 1: Constrained environment
In this scenario, data from (anaesthetized) fainted dogs were captured and the reference sensors were attached to the dog’s body. In the literature, data from fainted dogs are often collected to quantify the performance of VS extraction algorithms.
The dogs were brought to the operating room and received anaesthesia followed by the surgery (See Table 2). Afterwards, the fainted dogs were placed in front of the radar sensor for three minutes. The captured reference sensor and radar data were subjected to quality control. If either of sensor’s data was missing or invalid, the data collection process was repeated again.
Scenario 2: Unconstrained environment
As shown in Fig. 1, the dogs in this scenario were kept awake and they could move freely within an enclosed (ICU) chamber. Body-worn sensors were not attached; instead, a camera sensor was installed as a reference sensor. Medical experts quantified the breathing rate of the dog by observing the video frames. Note that before capturing data, the dogs underwent the surgery first and were brought to the ICU chamber where radar and a camera sensor was installed to capture data.
For performance benchmarking of HR and BR, the data collected in scenario 1 must be considered. However, the radar data collected in scenario 2 can be used to extract BR and HR while the ground truth values are available only for the BR.
Participants detail
Tables 2 and 3 shows the involved dogs for scenario 1 and 2 respectively. Ten dogs were included in scenario 1 and twenty dogs were included in scenario 2. Data collection was performed in the hospital on walk-in dogs, and their medical conditions are also included in Table 2. Note that all ten dogs in scenario 1 were in fainted condition. All the dogs employed in this work were small or medium to small sized dogs.
Data Records
The dataset is publicly available for download at the figshare repository22. The structure of the public repository is shown in Fig. 4. Two folders are created for each scenario shown in Fig. 1, and all the associated data are placed inside each folder. The Bionet folder contains the reference sensors data, and the folder named ‘Radar’ contains the radar data. Since three minutes of data were captured for scenario 1, the reference sensor data includes 180 samples. On the other hand, the radar data file consists of 9000 samples. For scenario 2, the data are recorded for thirty minutes, resulting in 90,000 radar samples, as illustrated in Fig. 4.
Technical Validation
Validation of the data collected in scenario 1
The simultaneously collected data from radar and clinical sensors are first synchronized in time, allowing us to compute the mean absolute error (MAE) and interclass correlation (ICCR). These two factors are extensively used in the literature to measure the similarity of two measurements14,16.
Table 4 shows the average MAE for BR and HR. The MAE between the radar and reference sensor for BR is 2.3 breaths per minute whereas for heart rate, the MAE is approximately 3.7 beats per minute. Participants two, eight, and nine showed the highest error in BR. For HR, participant five had the highest error of 6.6 beats per minute. The overall error for both the HR and BR is within the tolerable range.
MAE is an extensively used parameter for determining the limits of agreement between radar and reference sensor values for VS measurement. However, the MAE cannot quantify the ability of radar to track changes in VS measurements. Consequently, we also consider scatter plots, Bland–Altman plots, and the corresponding ICCR values in addition to the MAE for the fainted dog scenario.
Figure 5a,b shows the scatter plots and Bland–Altman plots for HR and BR, respectively. In the scatter plots, the vertical axis shows the clinical reference sensor observations, and the horizontal axis shows the radar observations. The thick black line shows the ideal case where the two quantities have a 100 percent match. In the Bland-Altman plots shown in Fig. 5a,b, the vertical axis represents the difference in the VS observations between the radar and reference sensor. The horizontal axis represents the absolute values of VS observations. In the ideal case, the difference should be zero, and the deviation from the ideal values must be within a tolerable range. As shown in Fig. 5, the BR and HR of our sample space spans between 12 and 24 breaths per minute and 100 and 150 beats per minute respectively.
The ICCR coefficients shown in Fig. 5a for the BR and HR is 0.902 and 0.930 respectively, and the dotted curves are near to the strong black line, suggesting a high correlation coefficient. Similarly, the deviation shown in the Bland-Altman plots is also less than 5 beats per minute. It can be concluded that the radar data in this data descriptor can be used for benchmarking the VS extraction algorithms.
Reliable measurement is an important aspect of any medical device. The Association for the Advancement of Medical Instrumentation (AAMI) and American National Standards Institute (ANSI) suggest that the error in terms of percentage for a consumer device must be < ± 10% for human HR measurements23. The average MAE for BR and HR in our case was 2.3 and 3.7, respectively. Perhaps apart from one or two cases that had higher error, the error was always low, and lies within the tolerance range. For the ICCR, any value above 0.7 is considered to indicate a high correlation between the two devices under observation. In our case, the ICCR value was above 0.9, suggesting a high correlation between the two measurements.
Validation of data collected in scenario 2
Figure 6 shows a thirty-minute history of three dogs chosen on the basis of the amount of movement made during their thirty minutes of stay in the ICU chamber shown in Fig. 2. Here, the green curve shows the body movement while staying inside the ICU chamber. The blue and brown dots show the HR and BR respectively. The HR and BR data points represent the average observations for ten seconds. As shown in Fig. 6, dog number 25 shows a very small amount of movement after 22 minutes of stay in the ICU chamber. A stable HR and BR are observed when the MI is low, which is the case when the dog is resting. Similarly, the dashboard for dog number 11 shown in Fig. 6 shows two instances when the dog is moving. Finally, the dashboard for dog number 15 shows several sharp movements with high magnitude. During these movements, the VS data appear like noise.
The dashboards shown in Fig. 6 suggest that radar sensors can be used for long term monitoring purposes. VS and body movement can be monitored in a continuous fashion, and the constructed dashboard can reflect the health status of dogs. Any abrupt changes in the VS or movement history can be observed on these dashboards and can be used as early indicators of hazardous situations. For instance, it was observed that dog number 15 made several movements while staying inside the ICU chamber, which can indicate that the dog is in a state of restlessness. Although we keep measuring vital signs when the dog is moving, the VS must be considered valid only when the movement index is also low, as illustrated in Fig. 6.
Usage Notes
We recommend the use of scenario 1 for benchmarking and validation purposes, followed by real-world implementation on scenario 2. The data in the second scenario are not for clinical validation of the algorithms since the data are captured without (clinical) reference sensor. Instead, scenario 2 can be used to test the feasibility of long-term monitoring using radar sensors. As shown earlier in Fig. 6, the vital signs and movement index extracted in scenario 2 are used to observe how stable the dog is.
The first step in processing the received data is the removal of clutter. The clutter removal filter is a simple recursive loop-back filter that estimates the clutter based on the current and previous output24. For convenience, the data are saved in an open-source CSV file format. We used the MATLAB 2021b software package for processing the data, and the script to load the data is included in the data descriptor. However, any suitable software package can be considered for this purpose.
Code availability
A MATLAB file named as load.m is included in the repository, as shown in Fig. 4. After extracting the dataset on the local computer, the users must run the load.m file using MATLAB R2020 or later. The file will automatically load the entire dataset into the MATLAB workspace.
Change history
29 January 2024
A Correction to this paper has been published: https://doi.org/10.1038/s41597-024-02993-y
References
Wang, P. et al. Method for distinguishing humans and animals in vital signs monitoring using ir-uwb radar. International Journal of Environmental Research and Public Health 16, 4462 (2019).
Kline, J. A. et al. Randomized trial of therapy dogs versus deliberative coloring (art therapy) to reduce stress in emergency medicine providers. Academic Emergency Medicine 27, 266–275 (2020).
Rowan, A. & Kartal, T. Dog population & dog sheltering trends in the united states of america. Animals 8, 68 (2018).
Taniguchi, M., Kageyama, T., Okamoto, Y., Matsunaga, T. & Lee, S.-S. A vital sign monitoring system using a mems microphone for dog. In 2023 IEEE 18th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), 70–73 (IEEE, 2023).
Wang, P. et al. Non-contact vital signs monitoring of dog and cat using a uwb radar. Animals 10, 205 (2020).
Varga, B., Gergely, A., Galambos, Á. & Kis, A. Heart rate and heart rate variability during sleep in family dogs (canis familiaris). moderate effect of pre-sleep emotions. Animals 8, 107 (2018).
Ahmed, S. & Cho, S. H. Hand gesture recognition using an ir-uwb radar with an inception module-based classifier. Sensors 20, 564 (2020).
Ahmed, S., Wang, D., Park, J. & Cho, S. H. Uwb-gestures, a public dataset of dynamic hand gestures acquired using impulse radar sensors. Scientific Data 8, 102 (2021).
Sadreazami, H., Bolic, M. & Rajan, S. Capsfall: Fall detection using ultra-wideband radar and capsule network. IEEE Access 7, 55336–55343 (2019).
Schleicher, B., Nasr, I., Trasser, A. & Schumacher, H. Ir-uwb radar demonstrator for ultra-fine movement detection and vital-sign monitoring. IEEE transactions on microwave theory and techniques 61, 2076–2085 (2013).
Lin, J. C. Noninvasive microwave measurement of respiration. Proceedings of the IEEE 63, 1530–1530 (1975).
Yoon, S., Ahmed, S. & Cho, S. H. Uwb radar-based pet monitoring on daily basis in an unconstrained living environment. In 2023 24th International Radar Symposium (IRS), 1–7 (IEEE, 2023).
Ma, Y. et al. An accurate method to distinguish between stationary human and dog targets under through-wall condition using uwb radar. Remote Sensing 11, 2571 (2019).
Shi, K. et al. A dataset of radar-recorded heart sounds and vital signs including synchronised reference sensor signals. Scientific data 7, 50 (2020).
Schellenberger, S. et al. A dataset of clinically recorded radar vital signs with synchronised reference sensor signals. Scientific data 7, 291 (2020).
Yoo, S. et al. Radar recorded child vital sign public dataset and deep learning-based age group classification framework for vehicular application. Sensors 21, 2412 (2021).
Raheel, M. S. et al. Breathing and heartrate monitoring system using ir-uwb radar. In 2019 13th International Conference on Signal Processing and Communication Systems (ICSPCS), 1–5 (IEEE, 2019).
Wiik, B. ANN based classification of humans and animals using UWB radar. Master’s thesis, NTNU (2018).
Ahmed, S., Kallu, K. D., Ahmed, S. & Cho, S. H. Hand gestures recognition using radar sensors for human-computer-interaction: A review. Remote Sensing 13, 527 (2021).
Lazaro, A., Girbau, D., Villarino, R. & Ramos, A. Vital signs monitoring using impulse based uwb signal. In 2011 41st European Microwave Conference, 135–138 (IEEE, 2011).
Kim, J. D. et al. Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates. Royal Society open science 6, 190149 (2019).
Ahmed, S., Yoon, S. & Cho, S. H. Dogs Vital Sign. Figshare https://doi.org/10.6084/m9.figshare.23820915.v1 (2024).
Nelson, B. W. & Allen, N. B. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth and uHealth 7, e10828 (2019).
Ahmed, S. & Cho, S. H. Machine learning for healthcare radars: Recent progresses in human vital sign measurement and activity recognition. IEEE Communications Surveys & Tutorials (2023).
Acknowledgements
This research was supported by the National Research Foundation of Korea (NRF-2022R1A2C2008783).
Author information
Authors and Affiliations
Contributions
S.Y. conducted the data collection using radar and reference sensors at the hospital and edited the paper. S.A. performed data processing, quality control and paper drafting. S.H.C. formulated the idea and conducted overall supervision.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ahmed, S., Yoon, S. & Cho, S.H. A public dataset of dogs vital signs recorded with ultra wideband radar and reference sensors. Sci Data 11, 107 (2024). https://doi.org/10.1038/s41597-024-02947-4