Background & Summary

Capillary actions are known to strongly influence the strength and flow properties of granular materials1,2,3,4, thus playing a fundamental role in several natural and engineering applications (e.g. slope stability5, earth construction6, building foundations7, caking in pharmaceutics8 and agriculture9 to name a few). These actions rise at the interfacial equilibrium (i.e. meniscus) between vapour and liquid phases within the pore network of granular materials and they are influenced by both the surface roughness and morphology of the grains.

However, most of the existing models on capillary phenomena in granular and porous materials rely on the assumptions of spherical and smooth particles10,11. As the capillary forces acting on spherical particles at the liquid-vapour interface can be described by the Young-Laplace equation, numerous numerical solutions have been developed based on the above simplifying assumptions12,13,14. Some studies have modelled capillary actions in multiphase sharp-edged particles15,16, but the boundary conditions for the contact angle at the sharp edges require additional assumptions that hinder the direct application of the Young-Laplace equation.

Only a handful of models have attempted to reproduce the effect of particle shapes and surface roughness on capillary actions rising within the porous network of granular materials17. However, a lack of experimental data on the retention behaviour of rough and irregular granular materials is hindering the further development of accurate analytical and numerical capillarity models18.

Interestingly, recent advances in imaging techniques allow for an unprecedented visualisation of liquid menisci forming in multiphase granular materials. For instance, Fig. 1 shows a Scanning Electron Microscopy (SEM) image of water menisci forming at inter-particle contacts between glass beads (scanned at LEMAS centre at the University of Leeds). By taking advantage of these advanced imaging tools, the present work provides the first experimental dataset investigating the effect of particle morphology and surface roughness on the onset of capillary menisci in granular materials. For this purpose, four types of granular materials (namely smooth and rough spherical glass beads, natural and roughened sands) have been subjected to drainage (drying) and soaking (wetting) paths during which X-ray micro-computed tomograms were taken at different saturation states, ranging from fully brine saturated to air dry conditions. The resulting datasets are made available online19,20,21,22 with the aim of further animating ongoing research from the scientific community on the influence of surface roughness and particle morphology on a broad range of capillary state variables, such as water, air and solid volumes (i.e. phases distribution), contact lines, contact angles, radii of curvature, interfacial areas (i.e. air-brine and brine-solid interfaces) as well as other features, such as sphericity of air bubbles, pore-scale processes and grain movements.

Fig. 1
figure 1

Scanning electron microscopy showing water menisci at inter-particle contacts of glass beads with a scale bar unit of 100 μm (a) and 20 μm (b).

Methods

Materials and sample preparation

X-ray micro computed tomography (µCT) scans were performed on smooth and rough spherical glass beads as well as natural and roughened sands to investigate the effect of surface roughness and particle morphology on the retention behaviour of granular materials. Both sands have a specific gravity of solid particles of 2700 kg/m3 while glass beads exhibited a lower value of 2500 kg/m3. All types of granular materials tested in the present work have a median particle size (d50) of 500 μm and they are mainly composed by silica. The surface of both sand particles and glass beads were mechanically roughened by milling the supplied materials following the technique described in the literature23,24,25. Measured by optical interferometry, the generated roughness root mean square height is in the range of 250–500 nm (<0.1% d50). The sphericity is 0.95 for the glass bead and is 0.86 for the sand. A dry mass of about 1.25 g for each tested material was measured by means of a balance with a resolution of 10−4 g and then inserted inside a testing tube. Inside this tube, each sample is sandwiched between a saturated high air entry value (HAEV) ceramic disc at the bottom and a metallic mesh at the top. The latter was needed to prevent sample particles from entering the drainage circuits and causing blockages. All samples had a diameter of 6 mm (i.e. nominal inner diameter of the testing tube) while the height was fixed at around 30 mm to target a value of dry density of about 1470 kg/m3. Sample height was measured by means of a calliper with a resolution of 10−2 mm. Table 1 summarises sample mass and dimensions as measured from both macroscopic measurements and µCT scans. The latter assume the same diameter of the macroscopic measurements and the height as the product of a voxel size of 6.2 μm and 1200 slices. Note that the sample height from the two measurements is different because µCT scans are only taken on a small mid-height portion of each sample. Table 2 lists instead the main physical properties (i.e. bulk and dry densities, void ratio and porosity) of each tested sample as determined from the macroscopic dimensions of Table 1. After insertion inside the testing tube, samples were subjected to drainage and soaking tests, as detailed in the following section.

Table 1 Samples mass and dimensions: macroscopic and microscopic determinations.
Table 2 Physical properties of all samples.

Drainage and soaking tests

After sample preparation, the testing tube containing the sample was inserted inside a vitton sleeve that enabled the application of a confining pressure of about 1.5 MPa by means of a Reaxus pump. The sleeve was then inserted into a core holder and the two extremities of the sample were connected to (i) a dual-piston pump from Vindum Engineering for brine or air injection/extraction and waste lines for drainage, (ii) a pressure transducer measuring differential pressure between air and brine and (iii) a confinement pressure line. Figure 2 shows both a schematic of the testing setup, which is similar to that adopted by Wang et al.26 (Fig. 2a) and the sample assembly together with brine inlet, air inlet, waste-lines (bottom and top) and confinement line (Fig. 2b). After assembly, the sample was lifted into position by means of a vertical motor and centred between the X-ray source and the detector before starting the µCT tests. Initially, two tomograms were taken on each sample under air dry and deionised water saturated conditions. These first two scans will serve for the segmentation and subsequent 3D reconstruction of the solid particles (i.e. sand grains and glass beads). Afterwards, each sample was saturated with brine prepared by mixing deionised water either at 7.5% or 5% concentration by mass of potassium iodine (KI), as shown in Table 3. These concentrations were selected because they gave an optimal contrast of the three different phases (grains, air and brine). Note that increasing the brine concentration from 5% to 7.5% changed the solution density from 1036 to 1054 kg/m3, the surface tension from 73.15 to 73.32 mN/m and the relative viscosity respect to distilled water at 20 °C from 0.984 to 0.978, as determined from experimental data published in the literature27,28,29. Afterwards, a scan was taken on the brine saturated sample before dry air (non-wetting fluid) or brine (wetting fluid) were either injected or extracted at a constant flow rate of 0.005 mL/minute to perform the desiccation and soaking paths. Tomograms were then regularly taken as capillary menisci started to form until samples were either almost completely air dried or brine saturated with only a few isolated menisci. Tables 3 and 4 illustrates the consecutive sequence of desiccation and soaking paths applied to both sands and glass beads samples, respectively. Only in one case, due to testing time extending over a two-day period, testing conditions were repeated as in the previous tomogram (i.e. for tomograms named ‘10.NaturalSand_Test10’ and ‘11.NaturalSand_Test11’). Between these two tomograms no further injections or extractions of dry air or KI brine were imposed, and these tomograms serve only the purpose of verification of equalisation of the differential pressure between air and brine after the overnight test pause. For all other cases, as the testing was completed on a single day, each tomogram refers to a successive testing step compared with the precedent one. Moreover, all types of flow occurred vertically with air injected from the top of the sample in the downward direction while brine was either injected upwardly or extracted downwardly from the bottom of the sample, as it can be deduced from Fig. 2. Note that volumes of injected or extracted fluid indicated in Tables 3 and 4 do not correspond to the fluid volumes entering or exiting the sample portion analysed via µCT scans. This is because it is not possible to have accurate measurements of the injected air volumes because of the compressibility of this fluid. Moreover, a fraction of the fluid volumes is needed to soak or drain the sample extremities which are not included in µCT scans. Hence, an accurate estimate of the brine and air volumes within the scanned part of the samples can only be obtained from the tomograms19,20,21,22. Tables 3 and 4 also include measured values of differential pressure between air and brine at the two extremities of the sample.

Fig. 2
figure 2

Schematic of the in situ µCT flow test set-up26 (a) and assembled roughened sand sample together with flow lines connections (b).

Table 3 Drainage and soaking paths applied to both natural and roughened sands.
Table 4 Drainage and soaking paths applied to both smooth and rough spherical glass beads.

Imaging Setup

A laboratory-based µCT system was used for all experiments. µCT is a non-destructive technique to image internal structures and dynamic processes in opaque materials. The emitted X-rays are scattered and absorbed by the sample, which causes X-ray attenuation. This is controlled by the X-ray energy and the absorbing material’s density and atomic number30. In the present work, all µCT scans were taken using the EMCT system located at the Centre for X-ray Tomography (UGCT) at Ghent University. This gantry-based system is designed for in situ imaging, where the sample remains stable and the X-ray source and detector rotate around the sample, as in Dierick et al.31. The scans were taken at 90 kV and 8 W, with an exposure of 120 ms and no filter was applied. Each projection consisted of four averages while 2001 projections were made per scan, which lasted for about 16 minutes.

Image reconstruction and processing

The scans were reconstructed using Octopus Reconstruction version 8.9.4.9 (XRE). Beam hardening and ring filtering were applied. The reconstruction parameters and final grey values were kept constant for each sample to allow comparison of the scans. An extra ring filter was applied in some instances, if necessary. The reconstruction resulted in 16-bit cross-sections (.tiff files) through the sample with a final voxel size of 6.2 µm. 3D images of the skeleton of glass beads and rough sand are illustrated in Fig. 3. These images are obtained after denoising the raw images by first removing the dark spots with a size equal or smaller than 3 pixels and then the bright ones with the same size. For the purpose of technical validation, the samples are then binarised by using Otsu thresholding to estimate the preliminary 3D threshold value. This also served to calculate void ratio and porosity, as shown in the Section ‘Technical Validation’.

Fig. 3
figure 3

3D skeleton of glass beads and rough sand samples both with a median particle size of 500 μm.

Data Records

All the data records are publicly available on Zenodo repository. The dataset is comprised of 15 scans for natural sand, 11 scans for rough sand, 8 scans for smooth glass beads and 14 scans for rough glass beads. Testing conditions were instead summarised in Tables 3 and 4 for natural and rough sands and smooth and rough glass beads, respectively. The DOIs are listed below:

Natural Sand19: https://doi.org/10.5281/zenodo.8073680

Roughened Sand20: https://doi.org/10.5281/zenodo.8074919

Smooth glass beads21: https://doi.org/10.5281/zenodo.8075767

Rough glass beads22: https://doi.org/10.5281/zenodo.8073825

Technical Validation

For the reconstructed images, the voxel size is 6.2 µm. However, the true image resolution refers to the finest detail distinguishable in the image, which depend on the voxel size, image blur and other artefacts. There is no universal measure that fully characterizes the true resolution. However, the Fourier ring correlation has been proposed as a fully automatic quantitative image-based measure without the need for prior information. This parameter is calculated using the Fourier Ring Correlation plugin in Fiji (ImageJ) on 2D slices of 3 different µCT images from the experiments32,33. This resulted in an average image resolution of 15.43 µm with a standard deviation of 0.49 µm. Table 5 compares the void ratio and porosity from both the macroscopic and the µCT measurements. Note that µCT scans are taken on a small mid-height portion of each sample under a confining pressure of 1.5 MPa. Hence, the discrepancies between the two measurements may have been generated by both edge effects and confinement. Despite these experimental constraints, the two macro- and micro-measurements of void ratio and porosity are indeed very similar, which confirms the good quality of the all the four datasets.

Table 5 Comparison of void ratio and porosity from macroscopic and microscopic measurements.