Abstract
Understanding the transmission of nanoscale forces in the pico-to-nanonewton range is important in polymer physics. While physical approaches have limitations in analyzing the local force distribution in condensed environments, chemical analysis using force probes is promising. However, there are stringent requirements for probing the local forces generated before structural damage. The magnitude of those forces corresponds to the range below covalent bond scission (from 200 pN to several nN) and above thermal fluctuation (several pN). Here, we report a conformationally flexible dual-fluorescence force probe with a theoretically estimated threshold of approximately 100 pN. This probe enables ratiometric analysis of the distribution of local forces in a stretched polymer chain network. Without changing the intrinsic properties of the polymer, the force distribution was reversibly monitored in real time. Chemical control of the probe location demonstrated that the local stress concentration is twice as biased at crosslinkers than at main chains, particularly in a strain-hardening region. Due to the high sensitivity, the percentage of the stressed force probes was estimated to be more than 1000 times higher than the activation rate of a conventional mechanophore.
Similar content being viewed by others
Introduction
Understanding the transmission of pico-to-nanonewton forces in complex hierarchical structures is a primary goal in polymer physics1,2,3 and mechanobiology4,5. Physical approaches such as optical/magnetic tweezers and atomic force microscopy (AFM) are widely used to evaluate piconewton (pN) force, but it is difficult to visualize the distribution of forces in condensed matter or molecular crowding environments with these techniques (Fig. 1a)6,7,8. While there are several instruments, such as surface force apparatuses (SFAs), rheometers, and tensile testing machines, that can analyze physical forces transmitted in meso-to-macroscopic structures, methods to directly quantify the distribution of forces at the molecular level are still being pursued. A promising alternative is chemical doping of mechanoresponsive molecules as a force probe9,10,11,12,13,14. These chromophores for materials and biological systems have been independently developed over the last few decades because the force magnitudes of interest are different in these fields. In the field of mechanobiology, Förster resonance energy transfer (FRET) dyads have been developed to analyze forces ranging from several to tens of pN15,16,17,18. On the other hand, various mechanophores respond to forces with higher thresholds involving internal covalent bond scission, which have produced a number of stress-responsive materials19,20,21,22,23,24,25,26,27,28,29,30,31,32. In particular, spiropyrans bearing different substituents have been reported to isomerize on 100 ms timescales under forces of 200–400 pN33,34, while density functional theory (DFT) calculations of most mechanophores have provided force thresholds on the order of a few nanonewtons35,36. Reversible responses have also been obtained in several mechanophores, even after covalent bond scission37,38,39,40. Recently, spiropyrans have also been used as a force probe to address important questions in polymer physics, including those related to load transmission and distribution at the single-chain (segmental) level9,10,11,12,13,14. However, there are still stringent requirements for the design of force probes that can quantitatively monitor local stress concentrations before the polymer chain network is structurally damaged but without changing the intrinsic properties of the polymer by chemical doping. Although sacrificial bond scission of polymer materials has been monitored using turn-on mechanophores9,10,11, fully understanding the distribution of nanoscale forces in entangled polymer chains is still challenging, and its importance becomes more obvious in the rational design of uniquely tough materials41,42,43,44,45,46,47,48,49. The target force range for this purpose is ~10–100 pN, which is below that for covalent bond scission (200 pN to several nN) and beyond that for spontaneous thermal fluctuation at room temperature (kBT = 4.1 pN nm)16,50 (Fig. 1b). Here, we demonstrate that a conformationally flexible flapping force probe enables this study by ratiometric analysis of its bright dual fluorescence (FL), in which the potential energy profiles in the ground state (S0) and the lowest singlet excited state (S1) are suitably designed. This high brightness allows minimal chemical doping to preserve the intrinsic polymer properties. Controlling the chemical location of the probe in crosslinked polymers and observing the dual emission from the stretched polymers in real time provided new quantitative insights into biased nanoscale stress concentrations.
Results and discussion
Dual-fluorescence flapping molecular probe
Dual-fluorescence flapping molecular probe
A flapping molecule (FLAP), composed of two rigid anthraceneimide wings fused with a conformationally flexible eight-membered ring (cyclooctatetraene, COT), shows dual FL properties (Fig. 2a, b)51. In S0, a bent form is most stable, while a planar form has higher energy due to the strain effect of the flat COT ring52. On the other hand, FLAP has two energy minima in S1 with bent and planar geometries. Emissions from these minima are both allowed, exhibiting blue FL at ~460 nm and green FL at ~520 nm. Since the energy barrier is low and the planar geometry is slightly more stable in S1, FLAP changes its conformation from bent to planar on a subnanosecond timescale after ultraviolet (UV) excitation in solution phase53, emitting predominantly green FL with a high FL quantum yield (ΦF ≈ 0.3). The population of excited species at these S1 minima is largely dependent on the local viscosity in solution, while the polarity dependence can be ignored due to the non-charge-transfer character. Whereas the viscosity-probing function is active in the presence of solvent molecules, the planarization dynamics across the barrier in S1 is suppressed in a polymer matrix, such that blue FL is mainly observed (ΦF ≈ 0.3). On the other hand, planarization in S0 can be mechanically induced by an external force, as we previously demonstrated the mechanophore function in a crystal phase transition of FLAP54. Among conformationally flexible mechanophores that can show detectable signals without covalent bond scission55,56,57,58,59,60,61,62, FLAP is unique in its dual FL properties, which enables ratiometric FL analysis (Fig. 2b). Although a variety of single-component dual-fluorescence chromophores have been reported in photochemistry63,64, force probe application has not been reported. By ratiometric FL analysis, quantitative evaluation can be realized even when the molecular force probes are distributed heterogeneously and the concentration of the probe changes by polymer deformation.
It is also meaningful to compare the working mechanism of the flapping force probe with that of the reported rigidochromic probes (categorized into fluorogenic molecular rotors), which can provide important microscopic insights into the friction force on a real contact area65,66. The similarity between the two probes can be seen in the mechanical control of the distribution of different excited-state species. On the other hand, the difference is the direction of the mechanically induced dynamics; namely, in the rigidochromic probe, the excited-state dynamics from the nearly Franck-Condon emissive geometry to another nonemissive geometry is suppressed in the confined space under mechanical compression. In contrast, the flapping force probe is initially confined with the bent form in a narrow free volume of the polymer materials67, but the population of the planarized species increases due to mechanical tension in the stretched polymer chain network (vide infra).
Force threshold for fluorescence switching before mechanical bond scission
Force threshold for fluorescence switching before mechanical bond scission
Flapping molecules bearing OH groups were prepared for covalent doping in polycarbonate (PC) and polyurethane (PU). Terminal bulky substituents were introduced to suppress aggregation of the FLAP probes68. Due to the high brightness, the doping ratio could be minimized to <10−4 equivalent to that of other monomer components. The original mechanical properties of the host polymers were preserved even after covalent doping (Supplementary Fig. 20 for PC and Supplementary Fig. 27 for PU), which is an essential requisite for a force probe. The average distance between the doped FLAPs was estimated to be ≈20 nm. Since the distance is much farther than that for FRET (<10 nm), the FRET-induced FL perturbation can be ignored. Negative control experiments by physical (noncovalent) doping of FLAP confirmed almost no mechanical response in terms of FL (Supplementary Fig. 38). In polymeric environments with chemical (covalent) doping, the sensitive mechanical response of this probe was confirmed. A linear PC sample prepared from the components in Fig. 2c showed glassy (nonelastomeric) behavior, with a glass transition temperature Tg of 153 °C (Supplementary Fig. 19). When the notched PC film was slowly stretched under an inverted microscope equipped with a small tensile tester and a hyperspectral camera, the rapid growth of the stressed area was visualized on a micro- to millimeter scale based on the resulting FL, which changed from a bluish to greenish color under UV light (Supplementary Movie 1). Two-dimensional imaging as a function of the FL ratio at 525- and 470-nm intensities (FL525/FL470) clarified the situation. The spectral response started much earlier than crack propagation from the notch (Fig. 2d). This result strongly suggested that the conformational planarization of FLAP can be specifically induced prior to covalent bond scission of the stressed polymer chains. In addition, compared with that in the crack tip front (region C), the FL ratio in a backward region of the crack (region B) decreased. This observation indicates that the FLAP force probe can trace the spatially transmitted relaxation process, while mechanically irreversible chromophores have a limitation in tracing relaxation after activation69.
To estimate the threshold of the FL switch at the single-molecule level, (time-dependent) DFT calculations were performed in S0 and S1 on a polymer substructure near FLAP (Fig. 3). The energy profile in S0 was obtained by plotting the relative potential energy of the optimized geometries with a fixed distance between terminal carbon atoms. At the most relaxed structure with a minimum energy, the corresponding distance was 40.4 Å (where extension = 0 Å), and the COT bending angle was 40.2°. Scanning the extension until 15 Å indicated that, in the early stage, the planarization of FLAP occurs specifically. The planarization completed by 12.0-Å extension is an energetically uphill process, but it requires only 6.7 kcal/mol. The steepness of the early-stage slope, which is the required force for conformational planarization, is several tens of pN. Further extension results in a rapid energy increase over a 200-pN slope. Eventually, the side chain is broken without bond scission in the FLAP skeleton. To determine the threshold for FL switching, the corresponding S1 energy profile must also be considered because a small conformational relaxation in S1 should be expected, even in the polymeric environment that suppresses a large structural change in principle67. Therefore, additional optimizations in S1 were conducted with the same extension value at each geometry as obtained in S0. As a result, S1 optimization from half-stretched structures below and above the 10.5-Å extension converged into two specific conformations of the FLAP skeleton, in which the COT bending angles were 28° (bent) and 0° (planar), respectively. The calculation result is consistent with the experimental results. The FL spectra of the stretched FLAP-doped PUs (see Fig. 4) showed a spectral change in only the relative intensity of the two FL bands at 474 and 525 nm, without a gradual redshift in wavelength. The observed unshifted FL bands indicate that the population of the excited species basically accumulates at the two S1 minima. Since the S1 relaxation of the FLAP skeleton proceeds on an ultrafast timescale53, polymer chains around the FLAP force probe cannot largely move at this instant. Based on these results, FL switching of the single FLAP molecule in the polymer substructure can be expected around the 10.5-Å extension, at which the threshold energy is calculated to be 4.5 kcal/mol with the required force of ~100 pN.
Controlling the chemical location of the force probe in crosslinked polyurethanes
Controlling the chemical location of the force probe in crosslinked polyurethanes
By controlling the chemical location of the FLAP force probe, we gained new quantitative insights into the biased local stress concentration of crosslinked PUs. Two different PUs, PU1 and PU2, were synthesized by chemical doping with FLAP1 and FLAP2, respectively (Fig. 4a). The photophysical properties of FLAP1 and FLAP2 were identical in solution. Due to the different numbers and positions of the reactive OH groups, FLAP1 is incorporated into PU main chains, while FLAP2 is incorporated into crosslinking points. Except for the difference in the probe locations, the following aspects of these PUs are all the same: stoichiometric amounts of monomer components, polymerization protocols using a tin catalyst, and preparation methods for dumbbell-shaped test specimens. Indeed, PU1 and PU2 as well as undoped PU (PU0) reproducibly showed almost identical mechanical and thermal properties (Fig. 4b and Supplementary Figs. 25–27). As shown Fig. 4, the crosslinking density, namely, the molar fraction of triethanolamine (TEA) to the sum of the monomers, was set to 0.10, while the molar ratio of FLAP1 and FLAP2 was small enough to be ignored, that is, 0.0001 equivalent to the poly(tetrahydrofuran) (PTHF) monomer (0.02 wt% to the obtained PUs). The stress–strain curve of the PU specimens indicated highly elastomeric properties (Fig. 4b). Typical rubbery deformations with Young’s modulus values of 1.0–1.1 MPa were confirmed for these PUs. The yield point was not clearly observed for the rubbery PU. After a typical plateau-like region at ~1 MPa, strain-hardening behavior started at ~500% strain, and rupture eventually occurred at ~750% strain at ≈6 MPa. It is worth noting that the rubbery PUs were gradually transformed into semicrystalline PUs within several days (Supplementary Figs. 39–41); however, we focused on rubbery PUs in this study.
Fluorescence spectroscopy simultaneously conducted with tensile testing
Fluorescence spectroscopy simultaneously conducted with tensile testing
During mechanical testing, the FL spectra of the PU specimens were measured in real time (Fig. 4c, d). Under continuous UV irradiation (365 nm, ≈100 mW cm−2), the FL emission was collected by an optical fiber connected to a multichannel photodetector. Before stretching, both PU1 and PU2 showed the same blue FL band with a single peak at 474 nm, corresponding to the emission from the bent FLAP conformation in S1. As the stress increased, a green FL band at 525 nm appeared along with vibronic subbands at 565 and 618 nm emitted from the planarized conformation. On the other hand, the blue FL band did not disappear in the late stage of stretching, meaning that considerable numbers of force probes were still relaxed even just before the specimens ruptured. Namely, the macroscopic stress was not ideally distributed over the whole polymer network. The nanoscale stress concentration cannot be discussed by using “turn-on” mechanophores that show no characteristic signal in their unactivated forms. More importantly, the relative degree of green FL enhancement was remarkably larger in PU2 than in PU1, clearly indicating biased nanoscale stress concentrations at the crosslinkers compared with the PU main chains. A stretch-induced absorption spectral change was also confirmed for PU2 (Fig. 4e). The appearance of a detectable absorption band in the long-wavelength region reaching 500 nm provided strong evidence for the compulsory conformational change of FLAP in the ground state. This weak absorption band was assigned to a partially allowed excitation in the visible range (Supplementary Table 13) for the effectively π-conjugated system of the fully planarized FLAP conformation in S0. A loading–unloading cycle test was also carried out to confirm the repeated and real-time response of the mechanically reversible force probe (Fig. 4f and Supplementary Fig. 36). The FL ratio excellently traced the time-dependent stress macroscopically loaded on the PU specimen. After rupture, the FL ratio immediately returned to the extent of the unstretched initial phase, which confirmed the reversible response of the FLAP force probe and the negligible influence of photodegradation.
Quantifying biased nanoscale stress concentrations by ratiometric fluorescence analysis
Quantifying biased nanoscale stress concentrations by ratiometric fluorescence analysis
The biased stress concentration at crosslinking points was demonstrated in every PU with different crosslinking densities of 8.7%, 10%, and 13% TEA (Fig. 5). The engineering stress–strain curves of these PUs are shown in Fig. 5a. The rupture stress and rupture strain decreased with increasing crosslinking density. The strain-hardening region of the highly crosslinked PU (13% TEA) started earlier at ≈400% strain, while that of the other PUs started at ≈500% strain. The FL ratios (FL525/FL474) were plotted as a function of macroscopic strain and stress (Fig. 5b, c), respectively. Here, we obtained an important insight. For all PU2 specimens containing FLAP at crosslinking points, the FL ratio remarkably increased in the strain-hardening region. This behavior is in sharp contrast to the moderately increased FL ratio in the PU1 specimens with FLAP at the main chains. In the plateau-like region of the stress–strain curve (observed below 1 MPa stress), the FL ratios were not largely different between PU1 and PU2, indicating that the local stress concentrations were observed to the same degree at the main chains and crosslinkers. However, the biased stress concentration at the crosslinkers became pronounced during the strain-hardening process above 1 MPa stress. With decreasing crosslinking density, the difference in the FL ratios between PU1 and PU2 at the rupture point increased. On the other hand, when we focused on the specific strain level in a strain-hardening region (for example, 600% strain), larger macroscopic stress was generated for more highly crosslinked polymers, and accordingly, the corresponding FL ratios were relatively larger at the same strain level. Based on spectral separation analysis of the dual FL signals, we estimated the corresponding percentage of the number of stressed FLAP probes over the threshold for FL switching (Fig. 5d and Supplementary Fig. 37), where the efficiencies of UV absorption and FL emission of the bent and planar conformations were theoretically considered. At a 10% TEA crosslinking density, the estimated percentage of the stressed probes at the rupture point reached 18 ± 2% (PU2) among the crosslinking FLAPs, whereas that in the main chains was ~9 ± 1% (PU1). Note that the low threshold of the FLAP force probe (theoretically predicted to be ≈100 pN) made the stressed probe percentage more than 1000 times larger than that of a reported mechanophore (diarylbibenzofuranone) that requires covalent bond dissociations70, demonstrating the suitability of FLAP for polymer physics studies.
Discussion
A ratiometric force probe with the dual fluorescence properties has been developed based on the design of flapping molecules (FLAP) bearing the rigid wings and the flexible joint. The stress-induced fluorescence spectral response, originating from the reversible conformational planarization, allows us to monitor stress concentration at the molecular level in deformed polymer chain networks prior to the structural damage by covalent bond scission. DFT calculations estimated the force threshold of the fluorescence switch at the single-molecule level to be ~100 pN, which corresponds to the force range below covalent bond scission (from 200 pN to several nN) and above thermal fluctuation (several pN). Chemically controlled doping of the force probe has led to new insights into the rheology of the crosslinked polymers. Namely, in a strain-hardening region, the local stress concentration is almost twice as biased at crosslinkers than at main chains. The ratiometric force probe has great potential to explore many other fundamental insights into the polymer physics of elastic materials.
Methods
Synthesis and purification
All reagents and solvents were of commercial grade and were used without further purification unless noted. Tetrahydrofuran (THF) was dried using a glass contour solvent purification system. Superdehydrated dimethylformamide (DMF) was purchased from Wako Chemicals. Poly(tetrahydrofuran) (Mn ~ 650) was dried under vacuum at 70 °C for 2 h before use. Thin-layer chromatography (TLC) was performed with silica gel 60 F254 (Merck). Column chromatography was performed using Wako gel C-300.
Measurements
1H and 13C nuclear magnetic resonance (NMR) spectra were recorded on a JEOL ECA-600 (600 MHz for 1H and 151 MHz for 13C NMR) spectrometer. Chemical shifts were expressed as δ in ppm relative to the internal standards CHCl3 (δ = 7.26 ppm for 1H and δ = 77.16 ppm for 13C) and DMSO (δ = 2.50 ppm for 1H and δ = 39.52 ppm for 13C). High-resolution atmospheric-pressure chemical ionization time-of-flight mass spectrometry (HR-APCI-TOF-MS) was performed on a BRUKER micrOTOF system in positive mode. Ultraviolet (UV)–visible absorption spectra were recorded on a Shimadzu UV-3600 spectrometer. Fluorescence (FL) spectra were recorded on a JASCO FP-8500 spectrofluorometer. Absolute FL quantum yields were determined on HAMAMATSU C9920-02S system. The FL lifetime was recorded on a Hamamatsu Photonics Quantaurus-Tau C11367 spectrometer. Tensile tests were carried out using a SHIMADZU AUTOGRAPH AGS-X tester with a 1-kN load cell at the crosshead. Differential scanning calorimetry (DSC) was performed on a Hitachi High-Tech TA7000 system. Rheological measurements were conducted on an Anton Paar MCR702 rheometer. Real-time FL measurements of PU specimens were performed using an Otsuka Electronics MCPD-6800 multichannel photodetector. Crossed Nicols images were obtained by a Leica DM2500 P optical microscope equipped with a Linkam LTS420E temperature control system. Photographs and movies of specimens were taken using an OLYMPUS Tough TG-6 digital camera.
Fluorescence microscopy imaging of the stretched polycarbonate film
This experiment was conducted by the combinational use of an inverted microscope (OLYMPUS IX83 inverted research microscope equipped with a U-HGLGPS mercury lamp), a tensile testing machine (AcroEdge OZ911 tensile testing machine) and a hyperspectral camera (EBAJAPAN NH-8 hyperspectral camera). A polycarbonate (PC) specimen (width ≈ 1 mm and thickness ≈ 0.03 mm) with a small notch was used for tensile testing. This specimen was held with an initial distance of 25 mm and extended from both sides at a speed of 0.05 mm s−1. Because of symmetrical stretching, the growing notch fits within the field of view of the microscope. At the same time, FL spectra at each pixel were collected with the hyperspectral camera. The data were acquired with an exposure time of 500 ms at a wavelength interval of 5 nm. FL optical micrographs (Fig. 2d, top) were taken by a digital camera (OLYMPUS TG-6), while the mapping images of the FL ratio (Fig. 2d, bottom) were obtained by analytical software (EBAJAPAN HSAnalyzer) based on the collected FL spectra.
Data availability
All data are available in the main text or the supplementary information.
References
Chen, Y., Mellot, G., van Luijk, D., Creton, C. & Sijbesma, R. P. Mechanochemical tools for polymer materials. Chem. Soc. Rev. 50, 4100–4140 (2021).
Simon Y. C. & Craig, S. L. Mechanochemistry in Materials. Vol. 26 (Royal Society of Chemistry, UK 2017).
O’Neill, R. T. & Boulatov, R. The many flavours of mechanochemistry and its plausible conceptual underpinnings. Nat. Rev. Chem. 5, 148–167 (2021).
Matellan, C. & del Río Hernández, A. E. Where no hand has gone before: probing mechanobiology at the cellular level. ACS Biomater. Sci. Eng. 5, 3703–3719 (2019).
Iskratsch, T., Wolfenson, H. & Sheetz, M. P. Appreciating force and shape — the rise of mechanotransduction in cell biology. Nat. Rev. Mol. Cell Biol. 14, 825–833 (2014).
Petrosyan, R., Narayan, A. & Woodside, M. T. Single-molecule force spectroscopy of protein folding. J. Mol. Biol. 433, 167207 (2021).
Bao, Y., Luo, Z. & Cui, S. Environment-dependent single-chain mechanics of synthetic polymers and biomacromolecules by atomic force microscopy-based single-molecule force spectroscopy and the implications for advanced polymer materials. Chem. Soc. Rev. 49, 2799 (2020).
Neuman, K. C. & Nagy, A. Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy. Nat. Methods. 5, 491–505 (2008).
Ducrot, E., Chen, Y., Bulters, M., Sijbesma, R. P. & Creton, C. Toughening elastomers with sacrificial bonds and watching them break. Science 344, 186–189 (2014).
Chen, Y., Yeh, C. J., Qi, Y., Long, R. & Creton, C. From force-responsive molecules to quantifying and mapping stresses in soft materials. Sci. Adv. 6, eaaz5093 (2020).
Chen, Y., Sanoja, G. & Creton, C. Mechanochemistry unveils stress transfer during sacrificial bond fracture of tough multiple network elastomers. Chem. Sci. 12, 11098–11108 (2021).
Stratigaki, M. & Göstl, R. Methods for exerting and sensing force in polymer materials using mechanophores. ChemPlusChem 85, 1095–1103 (2020).
Slootman, J. et al. Quantifying rate- and temperature-dependent molecular damage in elastomer fracture. Phys. Rev. X 10, 041045 (2020).
Chen, Y. et al. Fast reversible isomerization of merocyanine as a tool to quantify stress history in elastomers. Chem. Sci. 12, 1693–1701 (2021).
Freikamp, A., Cost, A.-L. & Grashoff, C. The piconewton force awakens: quantifying mechanics in cells. Trends Cell Biol. 26, 838–847 (2016).
Liu, Y., Galior, K., Ma, V. P.-Y. & Salaita, K. Molecular tension probes for imaging forces at the cell surface. Acc. Chem. Res. 50, 2915–2924 (2017).
Grashoff, C. et al. Measuring mechanical tension across vinculin reveals regulation of focal adhesion dynamics. Nature 466, 263–267 (2010).
Brockman, J. M. et al. Mapping the 3D orientation of piconewton integrin traction forces. Nat. Methods 15, 115–118 (2018).
Black, A. L., Lenhardt, J. M. & Craig, S. L. From molecular mechanochemistry to stress-responsive materials. J. Mater. Chem. 21, 1655–1663 (2011).
Brown, C. L. & Craig, S. L. Molecular engineering of mechanophore activity for stress-responsive polymeric materials. Chem. Sci. 6, 2158–2165 (2015).
Horst, M. et al. Understanding the mechanochemistry of ladder-type cyclobutane mechanophores by single molecule force spectroscopy. J. Am. Chem. Soc. 143, 12328–12334 (2021).
De, Bo,G. Mechanochemistry of the mechanical bond. Chem. Sci. 9, 15 (2018).
Binder, W. H. The “labile” chemical bond: a perspective on mechanochemistry in polymers. Polymer 202, 122639 (2020).
Deneke, N., Rencheck, M. L. & Davis, C. S. An engineer’s introduction to mechanophores. Soft Matter 16, 6230–6252 (2020).
Davis, D. A. et al. Force-induced activation of covalent bonds in mechanoresponsive polymeric materials. Nature 459, 68–72 (2009).
Caruso, M. M. et al. Mechanically-induced chemical changes in polymeric materials. Chem. Rev. 109, 5755–5798 (2009).
Chen, Y. et al. Mechanically induced chemiluminescence from polymers incorporating a 1,2-dioxetane unit in the main chain. Nat. Chem. 4, 559–562 (2012).
Li, J., Nagamani, C. & Moore, J. S. Polymer mechanochemistry: from destructive to productive. Acc. Chem. Res. 48, 2181–2190 (2015).
Chen, Z. et al. Mechanochemical unzipping of insulating polyladderene to semiconducting polyacetylene. Science 357, 475–479 (2017).
Imato, K. & Otsuka, H. Reorganizable and stimuli-responsive polymers based on dynamic carbonecarbon linkages in diarylbibenzofuranones. Polymer 137, 395–413 (2018).
Willis-Fox, N., Rognin, E., Aljohani, T. A. & Daly, R. Polymer mechanochemistry: manufacturing is now a force to be reckoned with. Chem 4, 1–39 (2018).
Schrettl, S. et al. Functional polymers through mechanochemistry. Chimia 73, 7–11 (2019).
Barbee, M. H. et al. Substituent effects and mechanism in a mechanochemical reaction. J. Am. Chem. Soc. 140, 12746–12750 (2018).
Gossweiler, G. R., Kouznetsova, T. B. & Craig, S. L. Force-rate characterization of two spiropyran-based molecular force probes. J. Am. Chem. Soc. 137, 6148–6151 (2015).
Klein, I. M., Husic, C. C., Kovács, D. P., Choquette, N. J. & Robb, M. J. Validation of the CoGEF method as a predictive tool for polymer mechanochemistry. J. Am. Chem. Soc. 142, 16364–16381 (2020).
Ribas-Arino, J. & Mark, D. Covalent mechanochemistry: theoretical concepts and computational tools with applications to molecular nanomechanics. Chem. Rev. 112, 5412–5487 (2012).
Gossweiler, G. R. et al. Mechanochemical activation of covalent bonds in polymers with full and repeatable macroscopic shape recovery. ACS Macro Lett 3, 216–219 (2014).
Imato, K. et al. Mechanophores with a reversible radical system and freezing-induced mechanochemistry in polymer solutions and gels. Angew. Chem. Int. Ed. 54, 6168–6172 (2015).
Wang, T. et al. Novel reversible mechanochromic elastomer with high sensitivity: bond scission and bending-induced multicolor switching. ACS Appl. Mater. Interfaces 9, 11874–11881 (2017).
Qian, H. et al. Fast, reversible mechanochromism of regioisomeric oxazine mechanophores: developing in situ responsive force probes for polymeric materials. Chem 7, 1081–1091 (2021).
Gong, J. P., Katsuyama, Y., Kurokawa, T. & Osada, Y. Double-network hydrogels with extremely high mechanical strength. Adv. Mater. 15, 1155–1158 (2003).
Okumura, Y. & Ito, K. The polyrotaxane gel: a topological gel by figure-of-eight cross-links. Adv. Mater. 13, 485–487 (2001).
Sun, J.-Y. et al. Highly stretchable and tough hydrogels. Nature 489, 133–136 (2012).
Filippidi, E. et al. Toughening elastomers using mussel-inspired iron-catechol complexes. Science 358, 502–505 (2017).
Matsuda, T., Kawakami, R., Namba, R., Nakajima, T. & Gong, J. P. Mechanoresponsive self-growing hydrogels inspired by muscle training. Science 363, 504–508 (2019).
Li, X., Nakagawa, S., Tsuji, Y., Watanabe, N. & Shibayama, M. Polymer gel with a flexible and highly ordered three-dimensional network synthesized via bond percolation. Sci. Adv. 5, eaax8647 (2019).
Liu, C. et al. Tough hydrogels with rapid self-reinforcement. Science 372, 1078–1081 (2021).
Wang, Z. et al. Toughening hydrogels through force-triggered chemical reactions that lengthen polymer strands. Science 374, 193–196 (2021).
Cai, P., Wang, C., Gao, H. & Chen, X. Mechanomaterials: a rational deployment of forces and geometries in programming functional materials. Adv. Mater. 33, 2007977 (2021).
Beyer, M. K. & Clausen-Schaumann, H. Mechanochemistry: the mechanical activation of covalent bonds. Chem. Rev. 105, 2921–2948 (2005).
Yuan, C. et al. A π-conjugated system with flexibility and rigidity that shows environment-dependent RGB luminescence. J. Am. Chem. Soc. 135, 8842–8845 (2013).
Wannere, C. S. et al. On the stability of large [4n]annulenes. Org. Lett. 5, 2983–2986 (2003).
Kotani, R. et al. Flapping viscosity probe that shows polarity-independent ratiometric fluorescence. J. Mater. Chem. C. 5, 5248–5256 (2017).
Yamakado, T., Otsubo, K., Osuka, A. & Saito, S. Compression of a flapping mechanophore accompanied by thermal void collapse in a crystalline phase. J. Am. Chem. Soc. 140, 6245–6248 (2018).
Ogi, S., Sugiyasu, K. & Takeuchi, M. Synthesis of a doubly strapped light-harvesting porphyrin bearing energy donor molecules hanging on to the straps: an attempt toward macroscopic control over molecular conformation that affects the efficiency of fluorescence resonance energy transfer. Bull. Chem. Soc. Jpn 84, 40–48 (2011).
Filonenko, G. A. & Khusnutdinova, J. R. Dynamic phosphorescent probe for facile and reversible stress sensing. Adv. Mater. 29, 1700563 (2017).
Filonenko, G. A. et al. Tracking local mechanical impact in heterogeneous polymers with direct optical imaging. Angew. Chem. Int. Ed. 57, 16385–16390 (2018).
Sagara, Y. et al. Rotaxanes as mechanochromic fluorescent force transducers in polymers. J. Am. Chem. Soc. 140, 1584–1587 (2018).
Sagara, Y. et al. Mechanically responsive luminescent polymers based on supramolecular cyclophane mechanophores. J. Am. Chem. Soc. 143, 5519–5525 (2021).
Muramatsu, T. et al. Rotaxane-based dual function mechanophores exhibiting reversible and irreversible responses. J. Am. Chem. Soc. 143, 9884–9892 (2021).
Straková, K. et al. HaloFlippers: a general tool for the fluorescence imaging of precisely localized membrane tension changes in living cells. ACS Central Sci. 6, 1376–1385 (2020).
López-Andarias, J. et al. Genetically encoded supramolecular targeting of fluorescent membrane tension probes within live cells: precisely localized controlled release by external chemical stimulation. JACS Au 1, 221–232 (2021).
Lee, M. H., Kim, J. S. & Sessler, J. L. Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules. Chem. Soc. Rev. 44, 4185–4191 (2015).
Behera, S. K., Park, S. Y. & Gierschner, J. Dual emission: classes, mechanisms, and conditions. Angew. Chem. Int. Ed. 60, 22624–22638 (2020).
Suhina, T. et al. Fluorescence microscopy visualization of contacts between objects. Angew. Chem. Int. Ed. 54, 3688–3691 (2015).
Weber, B. et al. Molecular probes reveal deviations from Amontons’ law in multi-asperity frictional contacts. Nat. Commun. 9, 888 (2018).
Goto, Y. et al. Dynamic polymer free volume monitored by single-molecule spectroscopy of a dual fluorescent flapping dopant. J. Am. Chem. Soc. 143, 14306–14313 (2021).
Yuan, C. et al. Hybridization of a flexible cyclooctatetraene core and rigid aceneimide wings for multiluminescent flapping π systems. Chem. Eur. J. 20, 2193–2200 (2014).
Celestine, A.-D. N., Sottos, N. R. & White, S. R. Strain and stress mapping by mechanochemical activation of spiropyran in poly(methyl methacrylate). Strain 55, e12310 (2019).
Imato, K. et al. Mechanochromic dynamic covalent elastomers: quantitative stress evaluation and autonomous recovery. ACS Macro Lett. 4, 1307–1311 (2015).
Acknowledgements
We thank Dr. Hiroya Abe and Dr. Yuta Saito (Tohoku Univ.) for their help in the early stage of the preliminary study. JST PRESTO (FRONTIER) and JST FOREST, Grant numbers JPMJPR16P6 and JPMJFR201L; MEXT/JSPS KAKENHI, Grant Numbers JP21H01917, JP21H05482, JP18H01952, JP20H04625, JP19KK0357, JP18H05482, and JP18J22477; Inoue Foundation for Science; Toray Science Foundation.
Author information
Authors and Affiliations
Contributions
H.Y. and S.S. conceived the concept. R.K., H.Y., and S.S. designed the experiments. R.K., S. Yokoyama, and S.N. performed the experiments. R.K. and S.S. conducted the quantum calculations. R.K. and S.S. analyzed the data. R.K. and S.S. wrote the manuscript, and S. Yamaguchi, A.O., and H.Y. proofread it.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks the anonymous reviewers for their contribution to the peer review of this work. Peer reviewer reports are available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kotani, R., Yokoyama, S., Nobusue, S. et al. Bridging pico-to-nanonewtons with a ratiometric force probe for monitoring nanoscale polymer physics before damage. Nat Commun 13, 303 (2022). https://doi.org/10.1038/s41467-022-27972-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-022-27972-y
This article is cited by
-
Stimuli-responsive smart polymers based on functional dyes
Polymer Journal (2024)
-
Environment-sensitive fluorescence of COT-fused perylene bisimide based on symmetry-breaking charge separation
Photochemical & Photobiological Sciences (2023)
-
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors
Nano-Micro Letters (2023)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.