Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Article
  • Published:

Implementing point of care ultrasound in the neonatal intensive care unit: a safety study

Abstract

Objective

Point of care ultrasound (POCUS) use is increasing in pediatrics and has been demonstrated to be superior in identifying central catheter tip location in neonatal intensive care units. However, limited data exist regarding cardiorespiratory changes secondary to POCUS in neonates.

Study design

A prospective observational equivalence study was performed on 50 POCUS assessments of central catheter tip location in 46 patients ≥23 weeks gestation. Heart rate (HR), respiratory rate (RR), and percent oxygen saturation (SpO2) levels were collected before and after POCUS. Limits of equivalence were set in advance.

Result

Equivalence was demonstrated in HR, RR, and SpO2 before and after POCUS. HR decreased by 3.24 beats per minute (90% CI: −5.36, −1.14). RR increased by 0.71 breath/min (90% CI: −1.84, +3.27). SpO2 increased by 0.54 percentage points (90% CI: −0.23, +1.31).

Conclusion

Identifying central catheter tip location using POCUS in neonates appears safe without affecting cardiorespiratory stability.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Fig. 1: Plots for heart rate in beats per minute (top left), respiratory rate in breaths per minute (top right), and percent oxygen saturation (SpO2) in percentage points (bottom center).

Similar content being viewed by others

References

  1. Miller LE, Stoller JZ, Fraga MV. Point-of-care ultrasound in the neonatal ICU. Curr Opin Pediatr. 2020;32:216–27.

    Article  Google Scholar 

  2. Meinen RD, Bauer AS, Devous K, Cowan E. Point-of-care ultrasound use in umbilical line placement: a review. J Perinatol. 2020;40:560–6.

    Article  Google Scholar 

  3. Bauer AS, Meinen R, Devous K, Al-Subu A, Cowan E. Introduction of point of care ultrasound into the neonatal intensive care unit. J Ultrasound. 2020;23:631–2.

    Article  Google Scholar 

  4. Zeileis A, Köll S, Graham N. Various versatile variances: an object-oriented implementation of clustered covariances in R. J Statist Softw. 2020;95:1–36.

    Article  Google Scholar 

  5. Cameron AC, Gelbach JB, Miller DL. Robust inference with multiway clustering. J Bus Economic Stat. 2012;90:414–27.

    Google Scholar 

  6. Chandrasekharan P, Rawat M, Reynolds AM, Phillips K, Lakshminrusimha S. Apnea, bradycardia and desaturation spells in premature infants: impact of a protocol for the duration of ‘spell-free’ observation on interprovider variability and readmission rates. J Perinatol. 2018;38:86–91.

    Article  CAS  Google Scholar 

  7. Suterwala MS, Reynolds J, Carroll S, Sturdivant C, Armstrong ES. Using fiberoptic endoscopic evaluation of swallowing to detect laryngeal penetration and aspiration in infants in the neonatal intensive care unit. J Perinatol. 2017;37:404–8.

    Article  CAS  Google Scholar 

  8. Custer J, Rau R. The Harriet Lane handbook eighteenth edition. Philadelphia, PA: Elsevier Mosby; 2009.

  9. Askie LM, Darlow BA, Davis PG, Finer N, Stenson B, Vento M, et al. Effects of targeting lower versus higher arterial oxygen saturations on death or disability in preterm infants. Cochrane Database Syst Rev. 2017;4:CD011190.

    PubMed  Google Scholar 

  10. Groves AM, Kuschel CA, Knight DB, Skinner JR. Cardiorespiratory stability during echocardiography in preterm infants. Arch Dis Child. 2005;90:86–7.

    Article  CAS  Google Scholar 

  11. Noori S, Seri I. Does targeted neonatal echocardiography affect hemodynamics and cerebral oxygenation in extremely preterm infants? J Perinatol. 2014;34:847–9.

    Article  CAS  Google Scholar 

  12. Lakens D. Equivalence tests: a practical primer for t tests, correlations, and meta-analyses. Soc Psychol Personal Sci. 2017;8:355–62.

    Article  Google Scholar 

  13. Fleming SE, Kim JH. Ultrasound-guided umbilical catheter insertion in neonates. J Perinatol. 2011;31:344–9.

    Article  CAS  Google Scholar 

  14. Franta J, Harabor A, Soraisham AS. Ultrasound assessment of umbilical venous catheter migration in preterm infants: a prospective study. Arch Dis Child Fetal Neonatal Ed. 2017;102:F251–F5.

    Article  Google Scholar 

  15. Guimaraes AF, Souza AA, Bouzada MC, Meira ZM. Accuracy of chest radiography for positioning of the umbilical venous catheter. J Pediatr. 2017;93:172–8.

    Article  Google Scholar 

  16. Hoellering AB, Koorts PJ, Cartwright DW, Davies MW. Determination of umbilical venous catheter tip position with radiograph. Pediatr Crit Care Med. 2014;15:56–61.

    Article  Google Scholar 

  17. Michel F, Brevaut-Malaty V, Pasquali R, Thomachot L, Vialet R, Hassid S, et al. Comparison of ultrasound and X-ray in determining the position of umbilical venous catheters. Resuscitation. 2012;83:705–9.

    Article  Google Scholar 

Download references

Funding

UnityPoint Health-Meriter Foundation provided grant money for this project.

Author information

Authors and Affiliations

Authors

Contributions

EC designed the study, helped to acquire and interpret data, helped to write and revise the manuscript, and contributed to final approval of the version to be published. RM helped to design the study, helped to collect and interpret data, helped to write and revise the manuscript, and contributed to final approval of the version to be published. ML helped to design the study, analyzed and interpreted the data, helped to write and revise the manuscript, and contributed to final approval of the version to be published. AA helped to design the study, helped to write and revise the manuscript, and contributed to final approval of the version to be published. AB helped to design the study, helped to collect and interpret data, helped to write and revise the manuscript, and contributed to final approval of the version to be published.

Corresponding author

Correspondence to Eileen Cowan.

Ethics declarations

Conflict of interest

The authors declare no competing interest.

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cowan, E., Meinen, R.D., Lasarev, M.R. et al. Implementing point of care ultrasound in the neonatal intensive care unit: a safety study. J Perinatol 41, 879–884 (2021). https://doi.org/10.1038/s41372-021-00955-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/s41372-021-00955-5

Search

Quick links