Abstract
Background & aims: To quantitatively characterise the rheological properties of newborn bloods using a Vilastic-3 rheometer.
Methods: Umbilical cord blood from 20 full term infants was characterised by Vilastic-3 rheometer and directly imaged by Linkam Imaging Station under capillary flow.
Results: Viscosity and elasticity: Viscosity remained constant over a range of shear rates. Elasticity decreased with increasing shear rates. Low shear rate (< 2s-1) elasticity was linear, RBCs existed in rouleaux and large aggregates, with minimal deformability. Intermediate shear rate (2s-1 to 100s-1) elasticity decreased, size of aggregates started to diminish and deformability of RBCs began to rise. High shear rate (>100s-1), elasticity dropped further, aggregates disappeared and deformability of red cells was dominant.
Effect of haematocrit: Relatively uniform increase in visco-elasticity properties with increase haematocrit. Only divergent sample was the only infant admitted to intensive care with breathing difficulty. G' and G'': newborn blood cannot be fitted by a single-mode Maxwell model. The slopes of G'' show the signature of non-Newtoian fluids.
Conclusions: This study quantitatively charcterised the flow behaviour of newborn blood and their rheological properties, including viscosity, elasticity, storage and loss moduli, as well as the structural evolution of rouleaux, aggregation & deformation of red blood cells. These rheological properties have also been identified as potential marker of pthology.
Article PDF
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
MacKinnon, R., Wai, J., Gottstein, R. et al. A Haemorrheological Characterisation of the Newborn Circulation at Birth. Pediatr Res 70 (Suppl 5), 259 (2011). https://doi.org/10.1038/pr.2011.484