Abstract
Visual resolution decreases rapidly outside of the foveal center. The anatomical and physiological basis for this reduction is unclear. We used simultaneous adaptive optics imaging and psychophysical testing to measure cone spacing and resolution across the fovea, and found that resolution was limited by cone spacing only at the foveal center. Immediately outside of the center, resolution was worse than cone spacing predicted and better matched the sampling limit of midget retinal ganglion cells.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$209.00 per year
only $17.42 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Green, D.G. J. Physiol. (Lond.) 207, 351–356 (1970).
Enoch, J.M. & Hope, G.M. Doc. Ophthalmol. 34, 143–156 (1973).
Williams, D.R. & Coletta, N.J. J. Opt. Soc. Am. A 4, 1514–1523 (1987).
Thibos, L.N., Cheney, F.E. & Walsh, D.J. J. Opt. Soc. Am. A 4, 1524–1529 (1987).
Marcos, S. & Navarro, R. J. Opt. Soc. Am. A Opt. Image Sci. Vis. 14, 731–740 (1997).
Curcio, C.A. & Allen, K.A. J. Comp. Neurol. 300, 5–25 (1990).
Dacey, D.M. J. Neurosci. 13, 5334–5355 (1993).
Polyak, S.L. The Retina (University of Chicago Press, Chicago, 1941).
Curcio, C.A., Sloan, K.R., Kalina, R.E. & Hendrickson, A.E. J. Comp. Neurol. 292, 497–523 (1990).
Roorda, A. et al. Opt. Express 10, 405–412 (2002).
Liang, J., Williams, D.R. & Miller, D.T. J. Opt. Soc. Am. A Opt. Image Sci. Vis. 14, 2884–2892 (1997).
Rossi, E.A., Weiser, P., Tarrant, J. & Roorda, A. J. Vis. 7, 1–14 (2007).
Bland, J.M. & Altman, D.G. Lancet 1, 307–310 (1986).
Anderson, R.S. & Thibos, L.N. J. Opt. Soc. Am. A Opt. Image Sci. Vis. 16, 2334–2342 (1999).
Drasdo, N., Millican, C.L., Katholi, C.R. & Curcio, C.A. Vision Res. 47, 2901–2911 (2007).
Acknowledgements
We thank K. Grieve for her assistance with data collection and P. Tiruveedhula for his help on software development. This work was supported by the National Science Foundation Science and Technology Center for Adaptive Optics under cooperative agreement AST-9876783 managed by the University of California, Santa Cruz and by National Institutes of Health grant EY014375.
Author information
Authors and Affiliations
Contributions
E.A.R. designed and performed the experiments, analyzed the data, and wrote the manuscript. A.R. supervised the project and edited the manuscript.
Corresponding author
Ethics declarations
Competing interests
Austin Roorda holds the patent Method and Apparatus for Using Adaptive Optics in a Scanning Laser Ophthalmoscope, which has been assigned to the University of Houston and the University of Rochester. The patent covers both the imaging and stimulus delivery applications of the technology described in this paper.
Supplementary information
Supplementary Text and Figures
Supplementary Figures 1–3, Supplementary Methods and Supplementary Discussion (PDF 379 kb)
Supplementary Video 1
AOSLO video showing retinal imagery and stimulus delivery. This video shows a tumbling E stimulus being delivered to the retina of observer S3. Cone photoreceptors appear as bright circles arranged in a roughly triangular lattice pattern. The motion of the retinal mosaic is due to normal fixational eye movements. This video has been processed in the following way: sinusoidal distortion caused by raster scanning was removed10,12,16; the aspect ratio was corrected to be 1:1; the video was cropped to be 0.75° × 0.75°. Although the stimulus appears quite sharp, this is due to the fact that the stimulus is delivered by modulating the imaging beam to be off. What the observer sees is a stimulus that is blurred by diffraction and any residual high-order optical aberrations that exist after adaptive optics correction. (AVI 6065 kb)
Supplementary Video 2
Stabilized AOSLO video. Video 2 shows a stabilized version of video 1. This video was stabilized using custom algorithms20 and illustrates how the normal fixational movements of the eye cause the stimulus to move across several photoreceptors over the course of a one second trial (30 frames). Stabilized videos such as these were averaged to produce the high signal to noise ratio images images which were used to build continuous maps of the photoreceptor mosaic for all individuals across test locations. Motion traces obtained through stabilization were used to determine the precise location of stimuli presented to the retina for resolution testing and for creating stimulation maps such as the one shown in Fig. 1. (AVI 6065 kb)
Supplementary Video 3
Animation showing modeled cone-stimulus interaction. This animation illustrates how cone models were used to examine the interaction between the stimulus and the photoreceptor mosaic. This video shows the cone-stimulus interaction that occurred during the trial shown in videos 1 & 2. This animation only shows a subsection of the area shown in videos 1 and 2; scale bar shows size relations. The left panel shows how the convolved stimulus moved across the cone mosaic, while the right panel shows the simulated cone interactions. The stimulus edges are enhanced (brightened) in the left panel to clearly illustrate where the contrast in the image fell to 50% of maximum. The color bar indicates the relative level of stimulation integrated over the course of the presentation for each cone. The change in color from blue to red as cones are stimulated over the course of the presentation illustrates how cone stimulation maps such as Fig. 1 were created. (MOV 200 kb)
Rights and permissions
About this article
Cite this article
Rossi, E., Roorda, A. The relationship between visual resolution and cone spacing in the human fovea. Nat Neurosci 13, 156–157 (2010). https://doi.org/10.1038/nn.2465
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/nn.2465
This article is cited by
-
A variation of foveal morphology in a group of children with hypermetropia
International Ophthalmology (2023)
-
Automated foveal location detection on spectral-domain optical coherence tomography in geographic atrophy patients
Graefe's Archive for Clinical and Experimental Ophthalmology (2022)
-
Morphology of partial-thickness macular defects: presumed roles of Müller cells and tissue layer interfaces of low mechanical stability
International Journal of Retina and Vitreous (2020)
-
Finely tuned eye movements enhance visual acuity
Nature Communications (2020)
-
In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
Scientific Reports (2020)