Abstract
The improved tumour to non-tumour ratios needed for effective tumour targeting with antibodies requires that blood background radioactivity is reduced. We investigated the effect of streptavidin as a clearing agent for 125I-labelled biotinylated anti-CEA antibodies in a human colon carcinoma xenograft model. By comparing the biodistribution of the monoclonal antibody A5B7 with four, nine or 22 biotins per antibody molecule, we investigated how the degree of biotinylation of the primary radiolabelled antibody affects its clearance with streptavidin. Limiting the degree of biotinylation limited blood clearance, whereas nine or 22 biotins per antibody molecule resulted in a 13- to 14-fold reduction in blood radioactivity, the streptavidin-biotinylated antibody complexes clearing rapidly via the liver and spleen. Although a reduction in tumour activity was also seen, a 6.6-fold improvement in the tumour to blood ratio was achieved. A comparative study of streptavidin versus second antibody clearance was carried out using the polyclonal antibody PK4S biotinylated with 12 biotins per antibody molecule. This study indicated that second antibody was superior for clearance of the polyclonal antibody, resulting in a larger and faster reduction in blood radioactivity and improved tumour to blood ratios. In this case the primary antibody was polyclonal, and therefore non-uniformity of biotinylation may affect complexation with streptavidin. Therefore, the degree of biotinylation and type of antibody must be carefully considered before the use of streptavidin clearance.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 24 print issues and online access
$259.00 per year
only $10.79 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Marshall, D., Pedley, R., Boden, J. et al. Clearance of circulating radio-antibodies using streptavidin or second antibodies in a xenograft model. Br J Cancer 69, 502–507 (1994). https://doi.org/10.1038/bjc.1994.91
Issue Date:
DOI: https://doi.org/10.1038/bjc.1994.91
This article is cited by
-
Effect of the immobilisation of DNA aptamers on the detection of thrombin by means of surface plasmon resonance
Analytical and Bioanalytical Chemistry (2008)
-
Pharmacokinetics of Monoclonal Antibodies
Clinical Immunotherapeutics (1996)