Key Points
In this part, we will discuss:
-
Re-evaluation of the implant retained prosthesis
-
Routine hygiene treatment requirements
-
Management of other specific complications
Abstract
Maintenance requirements vary with the complexity of treatment provided. In well planned and treated cases, complications should be rare.
Similar content being viewed by others
Main
The proposed success criteria for dental implant systems were described in Part 1. It has been suggested that longitudinal studies of implant systems should be a minimum of 5 years (preferably prospective studies rather than retrospective), with adequate radiographic and clinical supporting data to determine the level of failure and complication rate. As described in previous chapters, failure of osseointegration of individual implants should be relatively rare, with most failures occurring during the initial healing period or following abutment connection and initial loading. Longer term complications are associated with general wear and tear, inadequate attention to oral hygiene, poorly controlled occlusal forces, poor design of prostheses or use of an inadequately tested implant system.
Maintenance requirements and complications vary widely between patients, depending on susceptibility to caries and periodontal disease in the dentate patients, complexity and type of implant supported prostheses, functional demands and the patient's ability to attain an adequate standard of oral hygiene.
Re-evaluation of the implant retained prosthesis
It is generally recommended that patients treated with implant prostheses are seen at least on an annual basis, but in many cases they will also require routine hygienist treatment at 3, 4 or 6 monthly intervals according to individual requirements. At each re-evaluation appointment the following should be reviewed:
Condition of the prosthesis/restoration
The prostheses should be checked for signs of wear or breakage. Fixed restorations should have the cementation or screw fixation checked. This may include checking the screws which retain the prostheses and those which retain the abutments (see below). The occlusion should be re-evaluated, particularly where there has been occlusal wear of the prostheses or co-existing natural dentition. In published longitudinal studies of implant systems it was necessary to remove fixed bridge superstructures to evaluate the success of individual implants. However, this is not generally recommended in p patient follow-up unless there is suspicion that there is a problem with one of the implants. Fixed prostheses which have proved difficult to clean by the patient may require removal to allow adequate professional cleaning, which is easier with screw retained fixed prostheses than cemented types.
Removable prostheses need to be checked for retention and stability. In the case of prostheses with combined implant and mucosal support it is important to check that the implants are not suffering from overload caused by loss of mucosal support because of further ridge resorption. It has been suggested that removable prostheses often require more maintenance in the form of adjustment and replacement of retentive elements such as clips and 'ball retainers', compared with fixed prostheses.
Screw retention and crown cementation
Multiple units are more likely to be screw retained whereas the majority of single units are cemented. The screws retaining a prosthesis to the abutment are often covered with a layer of restorative material, such as composite or glass ionomer, which may need replacing. Screws which are accessible should be checked to ensure that they have not loosened. This is more likely to occur in an ill-fitting prostheses or where high loads have been applied (see the section on Implant Component Failure ).
Crown decementation of single tooth units is unusual, even in cases where a relatively weak temporary cement has been used. This is because of the close fit of the abutment to the crown, and in some cases a high degree of parallelism between them which may make separation impossible. A more common complication is failure to seat the crown at the original cementation because of failure to relieve hydraulic pressure within the crown using a cementation vent (fig. 1). The resulting poor marginal fit and exposure of a large amount of cement lute may result in soft tissue inflammation because of the increased bacterial plaque retention. A vent also helps to reduce excess cement being extruded at the crown margins which can give rise to considerable inflammation, including soft tissue abscess and fistula formation. Plaque retention and development of inflammation may also be the initial sign of a loose abutment (see below).
Abutment connection
Repeated chewing cycles may produce abutment loosening and development of a gap between abutment and implant. This complication can be largely prevented by attention to occlusal contacts and adequate tightening of the abutment screw in the first place by using specifically designed torque wrenches/hand pieces. Variations in the designs of abutment/ implant interface such as the morse taper of the ITI system, or internal conical seal of the Astra system, should reduce the occurrence of this complication. Abutment loosening is more likely to occur in patients with a parafunctional activity, in situations where inadequate attention has been paid to the occlusal contacts in all excursions, and rarely when the crown has been subjected to accidental trauma (fig. 2). Most single tooth restorations have cemented crowns with no direct access to the abutment for screw tightening. Therefore, should this be required, removal of the crown is necessary. It is important to note that under circumstances of direct trauma it is preferable to have a design system where hopefully a weaker and more easily replaceable component is damaged.
Status of the soft tissue
The standard of oral hygiene should be evaluated and the presence of supragingival calculus noted (see later the section on Routine Hygiene Treatment Requirements). The mucosa surrounding the implant abutments at the emerging restorations should appear free of superficial inflammation. The transmucosal part of the implant restoration may emerge through non-keratinised mucosa, particularly in situations where there has been severe loss of bone eg edentulous jaws. In contrast, many restorations emerge through soft tissue which appears very similar to adjacent keratinised gingiva. There are considerable differences between the appearances of these tissues, in that the non-keratinised mucosa will appear red, possibly more mobile and will have visible blood vessels within it. Gentle pressure on the exterior surface of the soft tissue should not result in any bleeding or exudate and will produce minimal discomfort. Probing depths may be evaluated but will depend upon the thickness of the original mucosa (see Part 2) and any overgrowth of gingival tissue which may have occurred. Ideally probing depths should be relatively shallow (< 4 mm) with no bleeding. If increased probing depths, soft tissue proliferation, copious bleeding, exudate or tenderness to pressure are found (fig. 3), the area should be examined radiographically (regardless of whether radiographic re-evaluation is scheduled) to determine whether there has been any loss of marginal bone or loss of integration. In these circumstances it may be advisable to dismantle the implant superstructure to allow adequate examination of individual abutments and implants.
Radiographic evaluation
Radiographs (fig. 4) are frequently used in implant treatment to evaluate:
-
Initial osseointegration
-
Seating of abutments
-
Fit of prostheses
-
Baseline bone level evaluation following completion of prosthetic treatment
-
Longitudinal evaluation of bone levels.
In all cases every effort should be made to minimise distortion and produce comparable reproducible images (see Part 5) to allow longitudinal assessment. Most implant systems report some bone loss in the first year following loading, followed by a steady state in subsequent years in the majority of implants. It would seem reasonable to radiograph annually for the first 3 to 5 years, then bi-annually up to 10 years in the absence of clinical signs or symptoms. If progressive bone loss is detected, the clinician has to decide whether this is most likely caused by bacteria induced inflammation or excessive loading (fig. 5). It may be very difficult to differentiate between the two, and in some circumstances the two factors may be combined.
Occlusal factors are more likely to be implicated in situations where there has been:
-
A history of parafunction
-
A history of breakages of the superstructure or retaining screws (or screw loosening)
-
An angular/narrow pattern of bone loss
-
Too few implants placed to replace the missing teeth
-
Excessive cantilever extensions.
Bacteria induced factors are more likely to be implicated where there is:
-
Poor oral hygiene
-
Retention of cement in the subgingival area
-
Macroscopic gaps between implant components subgingivally
-
Marked inflammation, exudation and proliferation of the soft tissue
-
Wide saucerised areas of marginal bone loss visible on radiographs.
This problem will be dealt with in the section on the treatment of peri-implantitis.
Routine hygiene treatment requirements
Re-evaluation of the implant retained prosthesis
-
Condition of the prosthesis/restoration
-
Screw retention and crown cementation
-
Abutment connection
-
Status of the soft tissue
-
Radiographic evaluation
The patient's oral hygiene should be reviewed and reinforced where necessary. An individual with a healthy dentition and a single tooth implant replacement should have the simplest maintenance requirements and few, if any, complications. The patient should be able to maintain the peri-implant soft and hard tissues in a state of health equivalent to that which exists around their natural teeth, almost without professional intervention (fig. 6). This can be achieved with routine toothbrushing and flossing. However, in some circumstances, the contour of the single tooth restoration is not ideal and instead of producing a smooth readily cleansable emergence profile, poor positioning of the implant may have resulted in a degree of ridge lapping (fig. 7). This will require modification of oral hygiene techniques to clean under the overhanging crown morphology, with dental tape or superfloss passed or threaded under the overhang. Single tooth restorations rarely have calculus formation on their highly glazed porcelain or polished gold surfaces. Professional scaling is not therefore ply required.
In patients with more complex fixed or removable prostheses development of readily cleansable embrasure spaces by the technician considerably facilitates patient's oral hygiene. Where calculus deposition has occurred, this should be removed. Calculus should be removed from titanium abutments with instruments which will not damage the surface (fig. 8). In many cases the abutments used are low profile with minimal exposure of the titanium surface subgingivally and this problem does not arise. Ultrasonic instruments and steel tipped instruments are contra-indicated.
Management of other specific complications
There are a number of complications which require early or urgent treatment.
Implant component failure
Retention and abutment screws which repeatedly loosen suggest either a poor fitting restoration superstructure or excessive loading. These factors require correction and proper management to avoid this complication and this is dealt with in Parts 4 and 7. Failure to deal with these problems, particularly in patients who exhibit parafunctional activities, may predispose to screw fracture (retention screws or abutment screws)(figs 5 and 9).
In many instances the fractured screw can be unwound by engaging the fractured surface with a sharp probe or using a commercially designed retrieval kit. The screw can then be replaced and due attention given to correction of the cause of the problem.
Fortunately, fracture of the implant is rare. It is more likely to occur with:
-
Narrow diameter implants, particularly when the wall thickness is thin
-
Excessive load
-
Marginal bone loss which has progressed to the level of an inherent weakness of the implant, often the level where wall thickness is thin at the apical level of the abutment screw.
Implant fracture is rarely retrievable, and requires either burying the fractured component beneath the mucosa or its removal (fig. 10). The latter can be difficult and traumatic, usually requiring surgical trephining which may leave a considerable defect in the jaw bone.
Soft tissue complications
Most inflammatory conditions can be corrected with attention to oral hygiene and professional cleaning. However, there are a number of instances which may require surgical correction:
-
Soft tissue overgrowth
-
Soft tissue deficiencies
-
Persistent inflammation/infection.
Soft tissue proliferation may occur under supporting bars of overdentures. It may require simple excision if there is adequate attached keratinised tissue apical to it, or an inverse bevel resection as used in periodontal surgery to thin out the excess tissue but preserve the keratinised tissue to produce a zone of attached tissue around the abutment. In direct contrast, some patients experience considerable discomfort because of trauma from the removable denture on mobile non-keratinised mucosa surrounding the abutment. The technique of free-gingival grafting can be used to correct this problem (see Part 8). Soft tissue problems may arise because of poor implant positioning. Persistent inflammation or discomfort may require recontouring of the soft tissues to allow patient cleaning, and this may reveal the less than satisfactory aesthetics produced by poor planning and execution of treatment (fig. 11). In other more severe cases the only remedy may be to remove the implants or bury them permanently beneath the mucosa. Poorly designed or constructed prostheses may need to be replaced, but in some cases this would also involve correction of the implant position. A compromise solution may therefore be sought.
Peri-implant lesions
In the case of well documented implants systems, inflammatory peri-implant lesions are rare. The possible aetiology of these lesions was described above and in Part 2. Potential occlusal factors should be diagnosed and corrected. Lesions which are thought to be caused by bacterial colonisation/contamination of the implant surface are managed in a similar fashion to lesions of periodontitis around teeth.
The keratinised mucosa should be preserved as much as possible, by employing an inverse bevel incision to separate it from the underlying inflammatory tissue. Following incision to bone the soft tissue flaps should be elevated to expose p adjacent bone. The inflammatory tissue surrounding the implant is readily removed (fig. 12). The main difficulty is adequately disinfecting the implant surface. This is more readily accomplished on a relatively smooth surface but may be almost impossible on a very porous surface such as a hydroxyapatite coating. Therefore, rough surfaces require more extensive debridement than a smooth surface which may be adequately disinfected using a topical antiseptic such as chlorhexidine or simple polishing. Inflammatory peri-implant lesions are not sufficiently common to have allowed comparison of different methods of cleaning to promote resolution of the soft tissue inflammation or repair of the bone. In cases where regenerative techniques have been used and bone fill has occurred, there is considerable controversy as to whether or not the regenerated bone forms a new osseointegration with the previously contaminated implant surface.
Conclusions
Regular review and maintenance of patients are essential to maintain the health of implant supporting tissues, to prevent minor complications and measure one's own long-term success at providing this treatment. With meticulous planning, provision of treatment and use of a tried and tested system, the complication rate is low. However, it is important to realise that complications do occur and for patients to appreciate the value of long-term care.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Palmer, R., Palmer, P. & Leslie, H. Complications and maintenance. Br Dent J 187, 653–658 (1999). https://doi.org/10.1038/sj.bdj.4800358
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.bdj.4800358
This article is cited by
-
Immediate versus delayed loading of strategic mini-implants under existing removable partial dentures: patient satisfaction in a multi-center randomized clinical trial
Clinical Oral Investigations (2021)
-
The effects of polishing methods on surface morphology, roughness and bacterial colonisation of titanium abutments
Journal of Materials Science: Materials in Medicine (2007)
-
Good occlusal practice in the provision of implant borne prostheses
British Dental Journal (2002)