Abstract
THE two most commonly used high-sensitivity detection devices for gas chromatography, the ‘flame ionization’1 and the ‘argon ionization’ detectors2, are insensitive to permanent gases. During an investigation into the various mechanisms responsible for ionization phenomena within the latter class of devices it was noted that under certain conditions of field and radioactive source strength, detector geometry and operating temperature, a simple ionization system using argon as carrier gas could be utilized to detect extremely low concentrations of permanent gases. The limit of sensitivity of this new mode of detector operation is up to 1,000 times greater than that reported with an earlier device3. In addition to this extraordinary response to fixed gases this same detector when operated at a different potential was found to retain certain characteristics, including the high sensitivity toward organic molecules as that noted by Lovelock2 for the conventional small ‘argon detector’.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 51 print issues and online access
$199.00 per year
only $3.90 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
McWilliam, I. G., and Dewar, R. A., Gas Chromatography, edit. by Desty, D. H., 2, 142 (Butterworths, London, 1958).
Lovelock, J. E., Gas Chromatography, edit. by Scott, R. P. W., 3, 9 (Butterworths, London, 1960).
Landowne, R. A., and Lipsky, S. R., Nature, 189, 571 (1961).
Hornbeck, J. E., Molnar, J. P., Phys. Rev., 84, 621 (1951).
Kaul, W., and Fuchs, R. Z., Naturforschung, 15, a, 326 (1960).
Field, F. H., and Franklin, J. L., J. Amer. Chem. Soc., 83, 4509 (1961).
Frank, Y. A., and Yanovskii, M. I., Kinetika i Kataliz, 2, 292 (1961).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
LIPSKY, S., SHAHIN, M. Sensitive Ionization System for the Detection of Permanent Gases and Organic Vapours by Gas Chromatography. Nature 197, 625–626 (1963). https://doi.org/10.1038/197625a0
Issue Date:
DOI: https://doi.org/10.1038/197625a0
This article is cited by
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.